Thames Water
Product
Guide Version 7.0
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 2/28
www.sensus.com
© 2015 Sensus. All rights reserved.
Contents
640e Smart Meter
iPerl Smart Meter
MeiStream Plus Smart Meter
MeiStream Plus (mechanical register)
MeiStream Plus-e (electronic register)
550 LCE Smart Point
SIRT
Correct as of Feb 2015
Contents to be updated periodica
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 3/28
Volumetric Meter - Composite
Body with Electronic Register
Applications
The 640C/640MC is a high precision meter.
Due to its unique piston and measuring chamber design, the smallest drops
of water are measured.
With the 640C/640MC you are assured of proven metrology of an established
meter with advantage of built in communications capability.
The 640C meter range includes an electronic register with integrated radio
functionality which enables easy and fast communication.
Due to our broad range of system solutions you can adapt the 640C/640MC toall your AMR, AMI requirements.
The protection class of the electronic register of the 640C family is IP 68 rated.
With a tamper proof design and its long life span you can be confident when
selecting the 640C/640MC.
Main characteristics
DN 15 to 20 and Coax, MAP 16, T50 (temperature
range 0,1 to 50 °C)
Light and robust
Easy to handle
Meets current and anticipated regulations forpotable water
Environmentally friendly
Unrivalled accuracy and measuring range
High resistance to impurities and aggressive water
Quiet operation
Ready for wireless communication with integrated
radio functionality (available in differentfrequencies)
Long lasting battery life expectation inclusive of
metrology and radio function
The register includes a lithium battery
www.sensus.com
640C
640MC
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 4/28LD1670INT Page 2
Typical Marking
Markings may vary depending on particular
markets or metrological specifications.
Accuracy and Reliability
Thanks to the advanced design of its measuring
chamber the meter has a low starting flow.
It can be supplied with metrological seal according
the MID regulation 2004/22/EC with a ratio up to
R400.
Foreign matter present in the water is filtered out
by either the tubular strainer on the inlet or the seat
strainer. All electronic components of the register
are hermetically sealed and assembled in a glasscopper casing which allow the protection class IP68.
The 640C/640MC water meter retains its
metrological accuracy for many years of operation,
even in difficult working conditions.
Typical Accuracy Curve
Typical Head Loss Curve
Cross Section
A c c u
r a c y ( % )
FlowQ1 Q2 Q3 Q4
D N 2 5
Flow rate (l/h)
10000
H e a d l o s s ( b a r )
0
1
640C DN15640MC
1
D N 1 5
D N 2 0
5
0
-5
2
-2
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 5/28
640C / 640MC
LD1670INT Page 3
Approvals
EC type-examination certificate
in conformity with
• 2004/22/EC (MID)
• EN 14154:2007
• OIML R49:2006
• ISO 4064:2005
Q3 2,5 DE-07-MI001-PTB002
Q3 4 DE-09-MI001-PTB004
Certificate of compliance for potable drinking water
KTW/DVGW (D) ACS (F)
WRAS (UK) Hydrocheck (B)
KIWA ATA (NL)
Legibility
The display with 9 digits (6 for m3, 3 for litres)
ensures exceptional readability. The highestresolution in testing mode is 0.05 litres.
Icons are also displayed on the LCD to indicate
important information have been registered:
Performance Data
Dimensions and Weights
Metrological characteristics
Directive 2004/22/EC (MID) & EN 14154:2007
(1) Values for R=400
(1) Also available in length 110/114/115/130/134 and 165 mm(2) Also available in length 165 and 190 mm with 1" threads(3) Also available in length 165 and 220 mm
640MC 640C
CoaxialManifold
Inline
Nominal Size DN mm # 15 20
Length L mm 170(1)
190(3)
Width D mm 101.7 101.7 113.5
Total height H mm 140.3 142.6 149
Height to pipe axis h mm 18.95 21.5
Tail Diameter inch G 1½" B G ¾" B(2)
G 1" B
Piece mm 47.8 26.44 33.25Thread Pitch 2.31 1.81 2.31
Weight kg 0.5 0.6 0.68
Dimensional Diagram
For the installation guidelines please refer to our website and the manual MD 1670 INT.
Coaxial
ManifoldInline
Nominal Size DN mm # 15 20
Permanent flowrate Q3 m³/h 2.5 2.5 4
Ratio “R” Q3 /Q1 R 40 / 80 / 160 / 315 / 400
Maximum flowrate(1)
Q4 m³/h 3.125 3.125 5.0
Minimum flowrate(1)
(tolerance ±5%)Q1 l/h 6.25 6.25 10.0
Transitional flowrate(1)
(tolerance ±2%)Q2 l/h 10.0 10.0 16.0
D
L
H
h
Alarm is triggered
Low battery level is reached
Radio is activated
System is set up in hydraulic testing mode
indicates positive or negative flow
indicates the unit programmed in use
H
D
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 6/28
UK & Ireland Enquiries
Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK
T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com
International EnquiriesSensus GmbH Ludwigshafen, Industriestrasse 16, 67063 Ludwigshafen Germany
T: +49 (0) 621-6904-0 F: +49 (0) 621-6904-1409 Email: [email protected] www.sensus.com
14001 Subject to changes without prior notice.LD1670INT Page 4
The 640C product range has SensusRF integrated
technology providing the advantages of both uni-
and bidirectional system architecture as described
below. SensusRF is the optimized radio system forbattery driven endpoints. Scalable for mobile and
remote reading without exchange of components, it
is available in 433 MHz.
Sensus offers two communication modes:
1. FlexNet™ Radio Network AMI
• 2 Way Long Range Radio AMI System
• Utility Grade Licensed Spectrum
• Direct to tower, minimal network infrastructure
• Excellent first time connection rates
• Easy integration of additional applications
(SCADA, acoustic loggers)
• Secure and resilient
• Meter reading transparent
• Fast track alarms
• DMA snap shot (snap shot of a water network
for evaluation)
• High level of data security (end-to-end
encryption)
SmartPoint
The SmartPoint (SP) radios are capable of 2 way
communications. The SP captures data wirelessly
from the 640C and transmits to the RNI via theTGB. The SP can receive data from the RNI such
as firmware upgrades and alarm configuration
changes.
2. Mobile Read - Walk-by / Drive-by AMR
• Unidirectional telegrams
• Bidirectional communication
• Spontaneous reception possible without route
• Configuration of the endpoint
SIRT (Sensus Interface Radio Tool)
SIRT is a radio modem for SensusRF radio,connected to a handheld via Bluetooth and using
SensusREAD Mobile Reading software with the
following features:
• Installation and readout of devices
• Reception of frequently transmitted radio
messages from Sensus RF radio endpoints
• Request additional information from the radioendpoints
• Change configuration of radio endpoints
(alarm level settings... )
640C/640MC infrastructure
Certified according to ISO 9001
Quality Management System Quality Austria Reg.no. 3496/0
433 MHz Drive-by
1000 m distance with 50 km/h speed
telegram with meter ID, index and alarm
Mobile Read - Walk by/ Drive by
5 0 0 m
640C/640MC FlexNet™ radio network - Remote Access & Monitoring
SP
SP
SP
SP AMI SmartPoint
TGB Tower Gateway BaseRNI Regional Network Interface
TGB
RNI
SIRT
SIRT linkedvia Bluetooth
with handheld
device
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 7/28
The evolution of technology associated with managing water networks and measuring consumption
is entering a new era. The era of iPERL.
Throughout history, the way that societies collect, distribute and gain access to potable
water has inspired a culture of invention and innovation…and this continues today with
iPERL, a breakthrough technology that defines a smarter future.
Simplicity, Productivity and Environmental Sustainability are the three axis of innovation
embodied in iPERL. No measurement technology has ever offered such intelligent end-
point data functionality. No measurement technology has ever provided the ability to createso much value through water network management and consumption accuracy.
iPERL - the new data end-point standard fully enabled for a new era.
DELIVERING ESSENTIAL VALUE THROUGH TECHNOLOGY INNOVATION
SIMPLE
iPERL is founded on
complete and simple
life-cycle principles.
From the selection of thenetwork fitting sizes for
the end-point, through
to delivery and usage
experience and on to
disposal, the technology
has been designed withsimplicity, productivity and
sustainability in mind.
ACCURATE
iPERL accuracy offers
real value throughout
its wide measuring range
independent of waterquality, network pressure or
piping section modifications.
No other current technology
can match iPERL.
LONG LASTING
iPERL delivers its core
values throughout its
complete life-cycle. Its
innovative measuringtechnology assures iPERL’s
enduring accuracy in
the field, delivering a
continuous data stream.
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 8/28
RELIABILITY
Extreme testing conditions, an innovative
mechanical design, extensive Sensus
experience and the blending of state-of-
the-art technologies ensure that iPERL
complies with T50 requirements, creating
a unique, robust and long-lasting water
data end-point.
Controlled Accuracy
As installation points are not always ideal,
iPERL has been designed for installation
in any orientation, independent of
flow direction and with no effect on
metrological performance.
LOW RISK
Investing in iPERL is investing in thefuture. Its inbuilt performance brings
considerable economic value with fast
ROIs and the flexibility to optimize future
opportunities.
iPERL’s inbuilt data logging allows utilities
to pro-actively monitor and adapt to
changing consumption habits, triggering
potential, additional consumer services.
Approvals
EC type-examination certificate
In conformity with
• 2004/22/EC (MID)
• EN 14154:2007
• OIML R49:2006
Certificate of Compliance For Potable
Drinking Water
In conformity with
• KTW / DVGW (D)
• ACS (F)
• WRAS (UK)
A PRODUCTIVITY engine
for the water NETWORK
TYPICAL ACCURACY CURVE
PRESSURE LOSS CURVE
PERFORMANCE DATA
PRODUCTIVITY
iPERL comes with an inbuilt R800 ratio for all models in the proposed family
range, from Q3 2.5 to 16 m3 /h. Such a value proposition means there is no
trade-off between performance and network conditions.
Due to its technology, iPERL’s R800 ratio meets utilities’ expectations
throughout iPERL’s life-time.
1.0
0.01
0.10
1.00
10.0
P r e s s u
r e L
o s s [ b a r
]
Nominal Diameter DN mm 15 20 25 30 40
Permanent flowrates Q3
m3 /h 2.5 4 6.3 10 16
Ratio “R” Q3 /Q
1R 800
Maximum Flowrate Q4
m3 /h 3.125 5 7.875 12.5 20
Minimum Flowrate Q1
l/h 3.13 5 7.88 12.5 20
Transitional Flowrate Q2
l/h 5 8 12.6 20 32
P r e s s
u r e
l o s s
[ b a r ]
D N 2 0
D N 1 5
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 9/28
ENVIRONMENTAL
iPERL is focused on achieving the lowest
possible environmental impact. Such
impact is measured through a complete
life-cycle analysis covering climate
change, ecosystem quality, human health
and natural resources.
iPERL was developed with disposal in
mind and is manufactured using fullyrecyclable materials.
iPERL is designed to meet the demands
of even the most severe field utilisations.
These include the fast open and close
tap movements that create fast flow
transients difficult to capture and
account for…and typical in residential and
commercial applications.
iPERL is fully protected against all water
network hazards. It is built to accommodateinterior and exterior installations. It is IP68
rated and fully protected against water
vapour transmissions that would occur
with the presence of any air.
Communications
iPERL is equipped with Sensus low
power 868MHz or 433MHz integrated
radio technology. Utilising a 1½ way
communication system, it offers both
the benefits of one and two way system
architecture. The innovative designprovides billing and alarm status for walk-
by / drive-by collection, plus in addition
the ability to interrogate the meter for
more detailed data including data logging
of up to 2880 values.
Along with Sensus Radio, iPERL also offers
an OMS certified T1 broadcast platform.
Long Range Radio
Sensus Radio will provide a link to the
long range radio infrastructure, FlexNet,allowing iPERL to be directly integrated.
With the utility grade communications
technology and whole life values of
iPERL, we offer a technology roadmap
fully aligned to a smarter future.
Dimensional Diagram
Dimensions
L H h B1 B2
DN15
110
120 26.5
92.5115
134
145
165104
170
DN20
10592.5
115
153
104165
190
LAY LENGTH
DN Available Lay Length (mm)Thread
acc.ISO
15 110 115* 134 145 165 170 3/4”
20 105 115 153 165 190 - 1”
25 198 260 - - - - 1 1/4”
30 260 - - - - - 1 1/2”
40 300 - - - - - 2”
* Also available with thread acc. ISO 3/4” x 7/8”
DN 15 / DN 20 DN 15 / DN 20
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 10/28
www.sensus.comLD 5000 INT 0001
I n c l u d e s s en s or t e c h n ol o g y
l i c en s e d b y S en t e c L i mi t e d
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 11/28
www.sensus.com
Applications
• Measurement for billing of cold potable water up to 50 °C
• Measurement of medium and high flowrates
• Measurement of low flow e. g. in light load periods
• For leakage control
Available options
• HRI-Mei factory mounted
• Version for use in hazardous area
• ¼" pressure monitoring port
• Encoder register with different data protocols
Main characteristics
• Meter with MID pattern approval acc. to annex
MI001
• Exchangeable metrological unit with MID patternapproval acc. to annex MI001
• Unique measuring range; Q3 /Q1 ≥ 315 in
horizontal installation
• High overload capability
• No straight inlet length necessary (U0D0 acc. to
OIML R49 and EN 14154)
• Meter body in short (WP) and long (WS) overalllength acc. to DIN 19625 and EN 14154 available
• Meter can be submerged; protection class IP68
• Used materials are temperature resistant upto 70 °C
• Register prepared for HRI-Mei pick-up
• Use of optical pulsers type OD is still possible
MeiStream
Plus
Class C Bulkmeter for coldpotable water DN 40...150 PN 16
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 12/28LB1060INT Page 2
Dial
Meter cpl. and exchangeablemetrological unit
Marking CE M-XX* 0102
DE-09-MI001-PTB 012
* year of production
Nominaldiameter
DN
Smallest reading
m3
Max. reading
m3
40 ... 100 0.0005 999,999.999
150 0.005 9,999,999.99
DN 40...100 DN 150
Performance Data
Size DN 40 50 65 80 100 150
Q5 Max. Peak Flow m³/h 50 55 60 120 160 400
Q3' Continuous Flow m³/h 30 35 40 63 100 250
Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63
Q1' Minimum Flow horizontal m³/h 0.08 0.07 0.1 0.13 0.2 0.35
Starting Flow m³/h 0.03 0.03 0.035 0.04 0.065 0.12
Size DN 40 50 65 80 100 150
Q4 Overload Flowrate acc. to MID m³/h 31.25 31.25 50 78.75 125 312.5
Q3 Permanent Flowrate acc. to MID m³/h 25 25 40 63 100 250
Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63
Q1 Minimum Flowrate horizontal acc. to MID m³/h 0.08 0.08 0.1 0.16 0.25 0.4
Q3/
Q1
max. Ratio 315 315 400 400 400 630
Q3/ Q1 Standard Marking 315 315 315 315 315 315
∆p Headloss at Q3 acc. to EN 14154 bar 0.09 0.08 0.17 0.07 0.16 0.14
Metrological Data acc. to Manufacturers Values
Metrological Data acc. to 2004/22/EC (MID)
Approval Mark
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 13/28
MeiStream Plus
LB1060INT Page 3
Typical Headloss
Materials
Typical Error Curve
Installation Requirements
Available Lengths
Pulse Values
Pulser Type Pulse Value
HRI-Mei (Leaflet see LS 8400) 0.01; 0.05; 0.1 or 1 m3 0.1; 0.5; 1 or 10 m3
OD 01 (Leaflet see LB 8300) 0.001 m3 0.01 m3
OD 03 (Leaflet see LB 8300) 0.01 m3 0.1 m3
DN 40 ... 100 DN 150
Pipe horizontal
Meter head upwards
• Unrestricted straight pipe upstream 0 x DN
• No abrupt restrictions directly downstream of the meter
Body Cast iron
Measuring element Plastic
Rotor Plastic
We also use the followingmaterials
Brass Stainless steel
Nominal diameter 40 50 65 80 100 150
Overall length L
WS (DIN / ISO)mm
270 /
300300
300 /
350
360 /
350500
Overall length LWP (DIN / ISO)
mm 220 200 200225 /
200250 300
Flowrate m3/h
H e a d l o s s
Q1 Q3Q2 Q4
5%
2%
2%
5%
m3/h
+
-
Flowrate m3/h
E r
r o r %
m³/h
Installation
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 14/28
Certified according to ISO 9001
Quality Management System Quality Austria Reg.no. 3496/0
UK & Ireland Enquiries
Sensus UK Systems Ltd, International House, Southampton International Business Park, George Curl Way,Southampton SO18 2RZ UK
T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com
International EnquiriesSensus GmbH Hannover, Meineckestraße 10, D-30880 Laatzen Germany
T: +49 (0) 5102 74-0 F: +49 (0) 5102 74-3341 Email: [email protected] www.sensus.com
12006 Subject to changes without prior notice.LB1060INT Page 4
Dimension and Weights PN 16
Order Information
Nominal diameter 40 50 50 50 65 65 80 80
Dimensions Overall length L mm 220 200 270 300 200 300 200 225
Height H mm 120 120 120 120 120 120 150 150
h mm 69 73 73 73 85 85 95 95
Dismantling height g mm 200 200 200 200 200 200 270 270
Weights Meter cpl. kg 7.5 7.8 9.6 9.9 10.1 12.0 13.8 14.2
Measuring insert kg 1.5 1.5 1.5 1.5 1.5 1.5 3.2 3.2
Body kg 6.0 6.3 8.1 8.4 8.6 10.5 10.6 11.0
Nominal diameter 80 80 100 100 100 150 150
Dimensions Overall length L mm 300 350 250 350 360 300 500
Height H mm 150 150 150 150 150 177 177
h mm 95 95 105 105 105 135 135
Dismantling height g mm 270 270 270 270 270 356 356
Weights Meter cpl. kg 16.3 17.7 18.2 20.0 20.2 35.9 44.2
Measuring insert kg 3.2 3.2 3.2 3.2 3.2 5.9 5.9
Body kg 13.1 14.5 15.0 16.8 17.0 30.0 38.3
MeiStream Plus, DN 50, T50, PN16
Drilling EN 1092 PN16
Length 270 mm
mechanical register / m³
with MID conformity
Type
Size
Max. medium temperature
Nominal pressure
Drilling pattern
Body length
Register type / unit
Approval standard
Dimension Picture
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 15/28
Class C Bulkmeter with
eRegister for cold potable
water DN 40...150 PN 16
Applications
• Measurement for billing of cold potable water up to 50 °C
• Measurement of medium and high flowrates
• Measurement of low flow e. g. in light load period
• For leakage control
• Integration into Smart Water Networks
Main characteristics
• Meter with MID pattern approval acc. to annexMI001
• Exchangeable metrological unit with MID
pattern approval acc. to annex MI001
• Unique measuring range; Q3/Q1 315 inhorizontal installation
• High overload capability
• No straight inlet length necessary (U0D0 acc.to OIML R49 and EN 14154)
• Meter body in short (WP) and long (WS)
overall length acc. to DIN 19625 and EN 14154available
• Meter can be submerged; protection class IP68
• Used materials are temperature resistant up
to 70 °C
• Register with integrated radio communication
• LC-display
www.sensus.com
MeiStream
Plus
Available options
•Radio communication with different frequencies
• ¼" pressure monitoring port
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 16/28LB1080INT Page 2
Dial
Meter cpl. and exchangeable metrological unit
Marking CE M-XX* 0102
DE-09-MI001-PTB 012
* year of production
Performance Data
Size DN 40 50 65 80 100 150
Q5 Max. Peak Flow m³/h 50 55 60 120 160 400
Q3' Continuous Flow m³/h 30 35 40 63 100 250
Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63
Q1' Minimum Flow horizontal m³/h 0.08 0.07 0.1 0.13 0.2 0.35
Starting Flow m³/h 0.03 0.03 0.035 0.04 0.065 0.12
Size DN 40 50 65 80 100 150
Q4 Overload Flowrate acc. to MID m³/h 31.25 31.25 50 78.75 125 312.5
Q3 Permanent Flowrate acc. to MID m³/h 25 25 40 63 100 250
Q2 Transitional Flowrate horizontal acc. to MID m³/h 0.13 0.13 0.16 0.25 0.4 0.63
Q1 Minimum Flowrate horizontal acc. to MID m³/h 0.08 0.08 0.1 0.16 0.25 0.4
Q3/ Q1 max. Ratio 315 315 400 400 400 630
Q3/ Q1 Standard Marking 315 315 315 315 315 315
∆p Headloss at Q3 acc. to EN 14154 bar 0.09 0.08 0.17 0.07 0.16 0.14
Metrological Data acc. to Manufacturers Values
Metrological Data acc. to 2004/22/EC (MID)
Alarm is triggered
Low battery level is reached
Radio is activated
System is set up in hydraulic testing mode
indicates positive or negative flow
indicates the unit programmed in use
Nominal
diameter
DN
Smallest readingm3
Max. readingm3
40 ... 100 0.001 999,999.999
150 0.01 9,999,999.99
Approval Mark
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 17/28
MeiStream Plus
LB1080INT Page 3
Typical Headloss Typical Error Curve
Installation RequirementsInstallation
• Unrestricted straight pipe upstream 0 x DN
• No abrupt restrictions directly downstream of the meterPipe horizontal
Meter head upwards
Materials
Body Cast iron
Measuring element Plastic
Rotor Plastic
We also use the following
materials
Brass
Stainless steel
Battery Lithium
Available Lengths
Nominal diameter 40 50 65 80 100 150
Overall length LWS (DIN / ISO)
mm270 /300
300300 /350
360 /350
500
Overall length LWP (DIN / ISO)
mm 220 200 200225 /
200250 300
Flowrate m3/h
H e a d l o s s
Q1 Q3Q2 Q4
5%
2%
2%
5%
m3/h
+
-
Flowrate m3/h
E r r o r
%
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 18/28LB1080INT Page 4
Dimension and Weights PN 16
Order Information
Nominal diameter 40 50 50 50 65 65 80 80
Dimensions Overall length L mm 220 200 270 300 200 300 200 225
Height H mm 120 120 120 120 120 120 150 150
h mm 69 73 73 73 85 85 95 95
Dismantling height g mm 200 200 200 200 200 200 270 270
Weights Meter cpl. kg 7.5 7.8 9.6 9.9 10.1 12.0 13.8 14.2
Measuring insert kg 1.5 1.5 1.5 1.5 1.5 1.5 3.2 3.2
Body kg 6.0 6.3 8.1 8.4 8.6 10.5 10.6 11.0
Nominal diameter 80 80 100 100 100 150 150
Dimensions Overall length L mm 300 350 250 350 360 300 500
Height H mm 150 150 150 150 150 177 177
h mm 95 95 105 105 105 135 135
Dismantling height g mm 270 270 270 270 270 356 356
Weights Meter cpl. kg 16.3 17.7 18.2 20.0 20.2 35.9 44.2
Measuring insert kg 3.2 3.2 3.2 3.2 3.2 5.9 5.9
Body kg 13.1 14.5 15.0 16.8 17.0 30.0 38.3
MeiStream Plus, DN 50, T50, PN16
Drilling EN 1092 PN16
Length 270 mm
eRegister / m³
with MID conformity
Type
Size
Max. medium temperature
Nominal pressure
Drilling pattern
Body length
Register type / unit
Approval standard
Dimension Picture
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 19/28
UK & Ireland Enquiries
Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK
T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com
International EnquiriesSensus GmbH Ludwigshafen, Industriestrasse 16, 67063 Ludwigshafen Germany
T: +49 (0) 621-6904-0 F: +49 (0) 621-6904-1409 Email: [email protected] www.sensus.com
14001 Subject to changes without prior notice.LB1080INT Page 5
The MeiStream Plus product range has SensusRF
integrated technology providing the advantages of
both uni- and bidirectional system architecture as
described below. SensusRF is the optimized radiosystem for battery driven endpoints. Scalable for
mobile and remote reading without exchange of
components, it is available in 433 MHz.
Sensus offers two communication modes:
1. FlexNet™ Radio Network AMI
• 2 Way Long Range Radio AMI System
• Utility Grade Licensed Spectrum
• Direct to tower, minimal network infrastructure
• Excellent first time connection rates
• Easy integration of additional applications
(SCADA, acoustic loggers)
• Secure and resilient
• Meter reading transparent
• Fast track alarms
• DMA snap shot (snap shot of a water network
for evaluation)
• High level of data security (end-to-end
encryption)
SmartPoint
The SmartPoint (SP) radios are capable of 2 way
communications. The SP captures data wirelessly
from the MeiStream Plus and transmits to the RNIvia the TGB. The SP can receive data from the RNI
such as firmware upgrades and alarm configuration
changes.
2. Mobile Read - Walk-by / Drive-by AMR
• Unidirectional telegrams
• Bidirectional communication
• Spontaneous reception possible without route
• Configuration of the endpoint
SIRT (Sensus Interface Radio Tool)
SIRT is a radio modem for SensusRF radio,connected to a handheld via Bluetooth and using
SensusREAD Mobile Reading software with the
following features:
• Installation and readout of devices
• Reception of frequently transmitted radio
messages from Sensus RF radio endpoints
• Request additional information from the radioendpoints
• Change configuration of radio endpoints
(alarm level settings... )
MeiStream Plus infrastructure
Certified according to ISO 9001
Quality Management System Quality Austria Reg.no. 3496/0
1000 m distance with 50 km/h speed
telegram with meter ID, index and alarm
Mobile Read - Walk by/ Drive by
5 0 0 m
MeiStream Plus FlexNet™ radio network - Remote Access & Monitoring
SP
SP AMI SmartPoint
TGB Tower Gateway BaseRNI Regional Network Interface
TGB
RNI
SIRT
SIRT linkedvia Bluetooth
with handheld
device
433 MHz Drive-by
SP
SP
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 20/28
DS-C-550M-WSMPT
FlexNet 550M Water SmartPoint
The FlexNetTM 550M Water SmartPoint
provides the capability of a stepped AMR to
AMI solution for Utilities. It is a device that
allows the Utility to deploy Water meters in
either mobile mode with Walk-by / Drive-by
reads, or in Long Range Radio mode using
Sensus FlexNetTM technology. This allowsthe Utility to deploy Water meters and utilize
the system from day one of deployment
if their requirement does not warrent
initial deployment of a Long Range Radio
infrastructure. Once the radio infrastructure
is installed, the SmartPoint can be remotely
switched from Walk By / Drive By to FlexNet
Long Range Radio without dispatching
engineers to site.
The FlexNetTM 550M Water SmartPoint
supports OFCOM-licensed frequencies in the410-430 MHz radio spectrum.
The SmartPoint offers several advantages
that control both deployment and operation
costs. It’s powerful radio transmitter can
broadcast over large distances and minimizes
collection infrastructure. Once the Smartpoint
is installed, its migratable, two-way system
platform can be updated without requiring
personnel to visit each meter and/or
inconveniencing customers.
Flexible Meter Reading
Applications• Advanced Meter Infrastructure (AMI) for water
• Supports over the air AMR to AMI transistion
Features
• Walk By / Drive by (SensusRF) support
• Long Range Radio (Sensus FlexNetTM)
• 15 Year lifespan
• Supports AES 256bit Encryption
• Easily mounted in any meter pit
• Firmware upgradable
• Battery powered
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 21/28
FlexNet 550M Water SmartPoint
Specications
8601 Six Forks Road, Suite 700
Raleigh, NC 27615
1-800-638-3748
For more information, visit us at sensus.com
© 2012 Sensus. FlexNet and SmartPoint are trademarks of Sensus. The Sensus logo is a registered trademark of Sensus.
This product is licensed by IntusIQ under one or more of the following patents: 6,249,516; 6,437,692; 6,914,893; 7,054,271; 7,103,511; 7,468,661; 7,697,492 and 6,891,838.
Operating Temperature +40 0C to -25 0C
Lifespan 15 Years
Battery C-cell or D-cell*
Security AES256 Encryption
Memory Firmware Upgradable
Physical
Characteristics
Width: 140.5mm x Height
62.71mm x Depth 63.38mm
WeightC-cell version 185 grams
D-cell version 235 grams*
Transmitter Power 1 Watt +30dBm nominal
+1/-2dBm, at 25C
FlexNet radio network - Remote Access and Monitoring
*D-cell version End of 2014
ServicePit set installation interfacing to the utility
meter via low power radio
Installation
Environment100% Condensing, Water submersable
Frequency Range 412-412 MHz / 422-424 MHz
Sensus RF
Modulation
Propriatary Narrow Band
2 FSK (100 kbps)
Sensus FlexNet
Modulation
7 FSK Half Baud, C&I (4.022 kbps)
13 FSK Half Baud, Priority (8.044 kbps)
7 FSK (8.044 kbps)
13 FSK (16.088 kbps)
2 FSK (5 kbps)
Mounting
Brackets
Mounting accessories are available to
ensure a secure and reliable tting can
be achieved for a variety of boundary
boxes and installation locations.
140mm
62.71mm
63.38mm(including weld ash)
20e/620Me FlexNet™ radio network - Remote Access & Monitoring
SP
SP
SP
SP AMI SmartPoint TGB Tower Gateway Base
RNI Regional Network Interface
TGB
RNI
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 22/28
Sensus Interface Radio Tool (SIRT433)Manual
MS 2511 INT SIRT, page [email protected]
On (yellow) On/Off indicationblinking : battery < 2,9V
RF and BT is switched offCharge (red) On: Battery charging
Blinking: charge < 10%Blinking for 5 sec: charge <50%
Bluetooth (blue) Bluetooth connection on/offBlinking: BT communication
Warnings SIRTwill be switchedoff next
Y+R+B blinking: Contact SensusY+R blinking: battery < 2,7V or
T<-20°C or T>60°C
USB Mini Plug Communication via USB virtualCOM portCharging the battery
On/Off switch Switching device on/off
Antenna plug For the connection of theexternal Sensus antenna(order no.04410537)
The backside clip can be used tocarry the SIRT on a belt. Toavoid rain entering theelectronics use the lids forexternal antenna plug and USBplug. The plugs must be on thebottom side. When wearing SIRTon your belt, be careful of theinternal antenna reception.Position and angle of the meterreader to the radio endpoint
influence the radio range.
SIRT uses a Lithium Ion battery which must behandled and charged according to this manual andwith the attached Sensus power supply device only.Opening the housing or using other accessories isforbidden and stops all warranty claims againstSensus. SIRT may only be used in environmentconditions set out at the end of this manual.
Parts of delivery (order no.: 04410538)1) SIRT radio modem with internal antennas for
Sensus-RF
2) USB cable with Mini B- and Type A-plug
3) 240/110V/50/60Hz mains power supply
4) This manual
Accessories:
1) External antenna order no.: 04410537
2) Battery change on request
3) Single 240/110V/50/60Hz mains power supply
Incl. USB cable order no.: 04410532
4) 12V car cigarette lighter power supply incl.
USB cable order no.: 04410533
5) Single USB cable order no.: 04410536
Short description:
SIRT is a radio modem for Sensus Radio connection
to the PSION handheld via Bluetooth and using
SensusREAD software with the following features:
• Receiving of frequently transmitted radio
messages from Sensus RF radio endpoints.
• Requesting more information from the radio
endpoints
• Chang ing configuration of radio endpoints
Note: SIRT supports Sensus-RF, but does notsupport Sensus((S))cout radio.
In addition, the SIRT can be connected to a desktopor laptop computer using USB or Bluetooth. Followsystem requirements acc. to SensusREADapplication software.SIRT provides 2 internal antennas and forwardsradio messages from the strongest one received(diversity function)
Pairing via Bluetooth:The pairing procedure must be done at the first useof SIRT with the computer or handheld.
Pairing with PSION Pro³
1) Switch on SIRT 2) Select Power
(Yellow LED on)
Select control panel
3) Check Bluetooth 4) Select Bluetooth in the
is enabled control panel
5) Select Scan All 6) Select SIRT_XXXXXXXX
and pair it
7) Use Passcode 1209 8) Define serial port (take
care that there is no conflict
with other devices)
9) Use your selected COM Port also for SensusREADsoftware for the Sensus RF channel
Pairing with desktop or laptop:
1) Check your computer’s manual for special
requirements installation advice and
compatibility.
2) Check your computer provides Bluetooth radio
(integrated or Bluetooth USB stick).
3) Switch on SIRT.
4) Open your Bluetooth manager and scan for
Bluetooth devices.
5) Select the SIRT and pair it with the password
“1209”.
6) Check which COM port is used.
7) Use this COM port also in SensusREAD.
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 23/28
Sensus Interface Radio Tool (SIRT433)Manual
MS 2511 INT SIRT, page [email protected]
Charging battery (general):Charging process starts only, when SIRT is switchedon; yellow LED. To charge the battery use the USBcable (part of delivery). Before 1st usage battery ischarged around 50% only and SIRT must becharged completely.Red LED for “Charge” will be switched on, whencharging starts.Charging stops and red LED is switched offautomatically, when battery is full or batterytemperature is above 40 °C or below 0 °C.
Charging via a computer:1) Computer is switched on and OS is started.
2) Connect the USB cable to your computer.3) Required time to charge an empty battery is
around 8h (while SIRT is switched on).
4) Take care that your computer will not be
switched off or enter Sleep Mode.
Charging via a mains power supply (part of
delivery):
1) Connect your power supply with mains power
or 12V car cigarette lighter.
2) Required time to charge an empty battery is
around 4h.
Note: The lifetime of a rechargeable battery isusually around 2 years. In case the working time of afully charged battery is decreased dramatically itmust be changed. Due to safety reasons it is notallowed to open SIRT housing and to use any otherbattery. Send SIRT back to a Sensus store frontoffice and order the battery change
Using external antenna:
1) Screw the aerial on the magnetic foot.2) Check for a good position of the magnet foot
on top of your car roof.
3) Make sure that the antenna is securely fixed
on top of the roof and connects to the roof’s
metal only.
4) Keep magnet foot clean and take care your
roof’s paintwork will not be damaged.
5) Connect the antenna cable with the aerial and
lead it to the car’s interior. Avoid squeezing
the cable in the car’s door or window. Cable
can be damaged and radio performance
drops. Keep cable length outside the car as
short as possible.
6) Be sure SIRT is switched off; yellow LED is
off.
7) Connect the antenna cable with SIRT antenna
plug.
8) Lead the antenna cable and fix SIRT in the car
in a way it will not distract your attention from
driving and traffic. Use the backside clip to fix
SIRT on the empty front-seat passenger’s
safety belt or find another safe position.
9) Always drive carefully and not faster than
50km/h or 30mph and follow any speed limits.
10) The user is responsible for a safe usage of the
equipment. If it is not possible to use the
equipment under traffic conditions safely, you
have to stop your car before you are allowed
to read a radio endpoint. You may not
configure or handle the SIRT while driving.
Note: Before starting communication via the externalantenna, make sure the antenna is really connectedwith SIRT. Radio communication via externalantenna plug without the antenna connected candamage or weaken the radio electronics!Use only Sensus accessories, including withoutlimitation Sensus external antenna with order no.04410537. Using other accessories or externalantennas is not in accordance with the radioapproval (see technical data) and can damage theradio. It is not allowed to use any other devices,
accessories or other parts that are not explicitlyallowed by Sensus.
Don’t use the external antenna if it is windy or evenduring thunderstorm conditions or if such weather isforecast.External antenna application is only for drive-byoperation. The external antenna is not recommendedto use while wearing SIRT on the belt.
The user has to ensure the correct fixing of theexternal antenna and is responsible for such. Sensusis not responsible for any harm caused by anincorrect fixing or operation, or any other incorrect
usage of the external antenna.
Using SIRT with other software:Without license agreement it is not allowed to useSIRT with other software applications thanSensusREAD.On demand you can get software DLL to integrateSensus RF reading in your own application inaccordance with the respective license agreement
Technical data:
Frequency 433 MHzPower TX 10 mW radio endpoints,
1 mW Wake up radio endpointsafter installation
Modulation 2-GFSK
SupportedProtocols
Sensus radio protocol RX/TX
Dimensions 95 x 145 x 35Weight 295gBluetooth
USBWater proofExternal
Antenna cable
Typicalduration ofusage with afully chargedbattery
Class II Interface
Version 2.0IP53 (without vacuum)
3,0m
12h
ApprovalsRadio frequency: R&TTE Directive 99/5/EGCE declaration: www.sensus.comRoHS compliant
Environment conditionsOperation: min. -18 °C / max + 60 °CStorage: min -20 °C / max + 60 °CCharging battery: min. 0 °C / max. 40 °C
Never use or switch on SIRT in an aircraft, insi dea petrol station or similar environment requiringEX proof.
Note: You must not leave the SIRT in the car in frontof the windows in the sun. Also after a fast change oftemperature there is a risk of humid condensation on
the inner electronic board. Switching on SIRTunder this condition without a break time coulddamage the electronics.
Any visible and valuable items left in a car mayattract thieves. Please make sure your SIRT or
any accessory does not get stolen.
Disposal:
This product contains a LithiumIon rechargeable battery.In the interest of protecting theenvironment, this battery may notbe disposed in household wasteafter its period of use.The local and nationalregulations for environmentalprotection are to be considered
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 24/28
The data interface and flexiblepulse output for Bulk Water Meters
www.sensus.com
HRI-Mei
Special Features
Compatible to bulk water meters with MeiStream and MeiTwin MID standard
register
Load-free inductive scanning of the meter’s pointer
Retrofitable
Detection of water flow direction
Electronic pulse output means no switch bouncing
Pulse-weight, mode and length can be changed on site
Self diagnostic and tamper detection
Battery lifetime up to 12 years. With external power supply i.e. a M-Bus
central unit lifetime can be expanded
Sealed housing (IP68)
Cable length 3 m
Description
The HRI-Mei is a data capture device for MeiStream
an MeiTwin MID bulk water meters. All MeiStream
standard registers are prepared to receive the HRI-
Mei.
The HRI-Mei can also be mounted afterwards
without breaking the meter’s seal.
The HRI-Mei provides a high resolution pulse
output with water flow direction detection.
Also the data interface can be used for M-Bus
applications or for MiniBus devices like MiniPad or
Sensus((S))cout-MB
With the HRI-Mei all known data interfaces with
Encoder, Electronic and Hybrid registers can be
replaced.
Depending on the register a second pulser like the
Opto OD can be plugged in additionally e.g. at the
MeiStream.
Also other applications requiring reed switches or
optical pulse outputs can be supported with only
this one data capture device.
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 25/28LS8400INT Page 2
Applications
Meter reading based for billing purposes i.e.
mobile reading systems.
Meter remote reading and profiling via cable fixed
networks with M-Bus, radio modem or GSM
network.
Industrial control applications with the FM-1D/K or
FM-2D/K
Data logging in conjunction with various data
loggers; i.e. CDL.
Logging and transfer of flow profiles in conjunction
with XENON internet access.
Robust design allows the use of the HRI-Mei in
harsh environments like flooded pits.
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 26/28
HRI-Mei
LS8400INT Page 3
Pulse Modes
The HRI-Mei provides 7 different pulse output modes via 2 lines.
Parallel usage of the pulse output and serial output is not recommended andmay cause problems depending on the application.
Mode B1:
is used for remote pulse collectors with only one pulse input.
I1: balanced pulses (*)
I2: alarm (**)
(*) Backward pulses are compensated by suppressing the same quantity offorward pulses
(**) alarms can be programmed for broken pipe, leakage, tampering, cable cutand indicated by ground level at the output.
Mode B2:
I1: Forward pulses
I2: Backward pulses
Mode B3:
I1: For-/Backward pulses
I2: signal for the flow direction (*)
(*) Ground level means reverse flow
Mode B4 (default):
as mode B1,but line I2 is inverted
Mode B5:
Opto-OD (NAMUR) pulse output (6 ms)
I1: pulses with flow direction code
I2: not used
Mode B6:NAMUR (as OD-AM) pulse output (7 ms)
I1: balanced pulses as mode B1
I2: not used
Mode B7:
Dual pulse output
I1: balanced pulses as mode B1
I2: same as I1
Temperature range:
HRI-Mei standard for cold water (30 °C) and warm water (50 °C).
Environmental temperature range: -10 °C ... +60 °C
Technical Data
cable length 3 m
Pulse output
According to pulse mode
Opto-OD (NAMUR) compatible:
programmable pulse weights
(10, 25,....1000) litre/pulse
Pulse length 6ms
NAMUR acc. EN 60947-5-6
Reed-RD compatible:
programmable pulse weights
(10, 25,....10000) litre/pulse
Pulse length 32, 128 or 500ms
max. Voltage 48 Vdc
max. current 0,2 A
max. switching capacity 4 W
Data interface
M-Bus and MiniBus (autodetected)
Autom. detection of baud rate (300/2400Bd) andtype of interface.
Data protocol according IEC870-5/EN1434-3
An Encoder mode provides an easy to use dataprotocol compatible to the encoder registers.
Transferred Data
Meter index
Fabrication number
Meter ID. equivalent to secondary address
Monthly meter index for programmable day
Meter index for programmable yearly key date andfor the year before
Min./max. water flow with date/time
Backward water volume with date/timeBroken pipe and leakage detection withprogrammable flow thresholds
Tamper detection (*)
The HRI-Mei can be programmed to transfer
selected information.
Programmable Data
All changeable data can be set with MiniCom
software via the M-Bus / MiniBus data interface.MiniCom download is free of charge from the
Sensus web site.
(*) Requires tamper target at the meter.
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 27/28
UK & Ireland Enquiries
Sensus UK Systems Ltd, International House, Southampton International Business Park,George Curl Way, Southampton SO18 2RZ UK
T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com
International EnquiriesSensus GmbH Hannover, Meineckestraße 10, D-30880 Laatzen Germany
T: +49 (0) 5102 74-0 F: +49 (0) 5102 74-3341 Email: [email protected] www.sensus.com
13005 Subject to changes without prior notice.LS8400INT Page 4
Classical Sensus pulsers and equivalent HRI-Mei mode
Order Information
Previous pulse outputs Litres/pulse
RD01, RD011 10 to 100.000 lpp
OD01, OD03, OD07-L, OD07-24V, OD07-24S 10 to 1.000 lpp
OD AM 10 to 1.000 lpp
OD02/EX(cold), special HRI-Mei variant 10 to 1.000 lpp
10 litre per pulses with 32 ms pulse length only.
All other pulse weights can be set to 500 ms pulse length.For DN150-300 min pulse weight 100 lpp.
HRI-Mei variant
(examples *) Settings Application Order no.
HRI-Mei/B1/D10/T500/50 °CPulse Mode 1 (open collector)Pulse weight 100 lppPulse length 500ms
Cold water for DN40....125 MEI1ACG2XX
HRI-Mei/B1D1/T32/50 °CPulse Mode 1 (open collector)Pulse weight 10 lppPulse length 32ms
Cold water for DN40....125 MEI1AAD2XX
HRI-Mei/B5/D1/T6/50 °CPulse Mode 5 (Namur)Pulse weight 10 lppPulse length 6ms
Cold water for DN40....125 MEI1EDD2XX
HRI-Mei-CDL/D1/50 °CPulse Mode 2Pulse weight 10 lppWith CDL plug
CDL data logging
Cold water for DN40....125MEI3XXD2XX
HRI-Mei/B1/D10/T500/50 °CPulse Mode 1 (open collector)Pulse weight 1000 lppPulse length 500ms
Cold water for DN 150.....300 MEI1ACK3XX
HRI-Mei/B1D1/T32/50 °CPulse Mode 1 (open collector),Pulse weight 100 lpp,Pulse length 32ms
Cold water for DN 150...300 MEI1AAG3XX
HRI-Mei/B5/D1/T6/50 °CPulse Mode 5 (Namur)Pulse weight 100 lppPulse length 6ms
Cold water for DN 150.....300 MEI1EDG3XX
HRI-Mei-CDL/D1/50 °CPulse Mode 2Pulse weight 100 lppWith CDL plug
CDL data logging
Cold water for DN 150.....300MEI3XXG3XX
**Further variants on request.
Pulse value 10 50 100 250 500
Pulse length 32 128 500 32 128 500 32 128 500 32 128 500 32 128 500
10 l
pointer
40 DN x x - x x x x x x x x x x x x
50 DN x x - x x x x x x x x x x x x
65 DN x x - x x x x x x x x x x x x
80 DN x - - x x x x x x x x x x x x100 DN x - - x x - x x x x x x x x x
125 DN x - x x - x x x x x x x x x
100 l
pointer
150 DN not possible x x - x x x x x x
200 DN not possible x x - x x x x x x
250 DN not possible x x - x x - x x x
300 DN not possible x - - x x - x x x
Possible pulse values
Certified according to ISO 9001
Quality Management System Quality Austria Reg.no. 3496/0
8/19/2019 Sensus Product Brochure v7 (May 2015)
http://slidepdf.com/reader/full/sensus-product-brochure-v7-may-2015 28/28
Sensus UK Systems Ltd
3 Lindenwood
Crockford Lane
Chineham Business Park
Basingstoke,
RG24 8QY UK
+44 20 7112 1565