49
PREPARED BY: SEPP No.65: DESIGN VERIFICATION STATEMENT 105 CUDGEGONG ROAD, ROUSE HILL RESIDENTIAL FLAT BUILDINGS

SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

PREPARED BY:

SEPP No.65: DESIGNVERIFICATION

STATEMENT

105 CUDGEGONG ROAD, ROUSE HILLRESIDENTIAL FLAT BUILDINGS

Page 2: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

2

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Lawrence Zheng is registered as an Architect in New South Wales and enrolled in the Division of Chartered Architects in the register of Architects pursuant to the Architect Act 1921.

His Architect Registration Number is 10061(NSW).

Statement of Design - SEPP No. 65

Lawrence Zheng has been responsible for the project, and has worked with related professionals and experts in respect of the matter. The proposal of residential flat building development at 105 Cudgegong Road, Rouse Hill, responds to the best practice of design principles that set out in SEPP No. 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no impact on the objectives.

Yours faithfully,

Lawrence ZhengArchitectRegistration Number 10061

Verification of Qualifications

Page 3: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

3

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

CONTENTS

SECTION A

1. Introduction

SECTION B

1. Context and Neighbourhood Character

2. Built Form and Scale

3. Density

4. Sustainability

5. Landscape

6. Amenity

7. Safety

8. Housing Diversity and Social Interaction 9. Aesthetics SECTION C

1. Conclusion

APPENDIX

1. Compliance Table

2. Numeric Compliance Table

4

7

12

17

18

23

25

28

29

32

35

36

48

Page 4: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

4

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

This statement is for a development application submitted for a residential flat building development which contains two hundred and one units at 105 Cudgegong Road, Rouse Hill.

This design statement is prepared by the Dreamscapes which has been assigned as the architects for the subject development.

This statement aims to demonstrate that the subject development proposal can achieve the requirements of 9 Design Principles that outlined in SEPP 65-Design Quality of Residential Flat Development (Amendment No.3). The statement will individually assess the design performance and compliance of these nine principles in the following section.

*Good design responds and contributes to its context. Context is the key natural and built features of an area, their relationship and the character they create when combined. It also includes social, economic, health and environmental conditions.

Responding to context involves identifying the desirable elements of an area’s existing or future character. Well-designed buildings respond to and enhance the qualities and identity of the area including the adjacent

Introduction

Section A

sites, streetscape and neighbourhood. Consideration of local context is important for all sites, including sites in established areas, those undergoing change or identified for change.

* Good design achieves a scale, bulk and height appropriate to the existing or desired future character of the street and surrounding buildings.

Good design also achieves an appropriate built form for a site and the building’s purpose in terms of building alignments, proportions, building type, articulation and the manipulation of building elements. Appropriate built form defines the public domain, contributes to the character of streetscapes and parks, including their views and vistas, and provides internal amenity and outlook.

*Good design achieves a high level of amenity for residents and each apartment, resulting in a density appropriate to the site and its context.

Appropriate densities are consistent with the area’s existing or projected population. Appropriate densities can be sustained by existing or proposed infrastructure, public transport, access to jobs, community facilities and the environment.

Page 5: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

5

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Good design combines positive environmental, social and economic outcomes. Good sustainable design includes use of natural cross ventilation and sunlight for the amenity and liveability of residents and passive thermal design for ventilation, heating and cooling reducing reliance on technology and operation costs. Other elements include recycling and reuse of materials and waste, use of sustainable materials, and deep soil zones for groundwater recharge and vegetation.

* Good design recognises that together landscape and buildings operate as an integrated and sustainable system, resulting in attractive developments with good amenity. A positive image and contextual fit of well-designed developments is achieved by contributing to the landscape character of the streetscape and neighbourhood. Good landscape design enhances the development’s environmental performance by retaining positive natural features which contribute to the local context, co-ordinating water and soil management, solar access, micro-climate, tree canopy, habitat values, and preserving green networks. Good landscape design optimises usability, privacy and opportunities for social interaction, equitable access, respect for neighbours’ amenity, provides for practical establishment and long term management.

*Good design positively influences internal and external amenity for residents and neighbours. Achieving good amenity contributes to positive living environments and resident wellbeing. Good amenity combines appropriate room dimensions and shapes, access to sunlight, natural ventilation, outlook, visual and acoustic privacy, storage, indoor and outdoor space, efficient layouts and service areas, and ease of access for all age groups and degrees of mobility.

* Good design optimises safety and security, within the development and the public domain. It provides for quality public and private spaces that are clearly defined and fit for the intended purpose. Opportunities to maximise passive surveillance of public and communal areas promote safety.

A positive relationship between public and private spaces is achieved through clearly defined secure access points and well-lit and visible areas that are easily maintained and appropriate to the location and purpose.

*Good design achieves a mix of apartment sizes, providing housing choice for different demographics, living needs and household budgets.

Page 6: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

6

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Well-designed apartment developments respond to social context by providing housing and facilities to suit the existing and future social mix. Good design involves practical and flexible features, including different types of communal spaces for a broad range of people, providing opportunities for social interaction amongst residents.

* Good design achieves a built form that has good proportions and a balanced composition of elements, reflecting the internal layout and structure. Good design uses a variety of materials, colours and textures.

The visual appearance of well-designed apartment development responds to the existing or future local context, particularly desirable elements and repetitions of the streetscape.

Page 7: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

7

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Proximity to the Transport & Services

The site is located around 800 meters (10 mins walking distance) from Cudgegong Road train station which will be completed in 2019. And it is around 4.5 km to Schofield train station and 5.5 km to Riverstone train. Therefore, the site is benefited by multiple existing and future public transportation. The Rouse Hill town centre is around 2.7 km away from the site, with approximately 70,000sqm retail commercial.

The adjoining lands includes medium to low density residential area(R2/R3), infrastructure area (SP2) and public recreational open space(RE1). The lots on the north, south, east and west of the site are also zoned as R3 medium density residential, and the land zoning to the northeast is SP2 & R2 for infrastructure, public open space and low density residential area.

There are around 36,500 square meters public accessible open space in the subject site. There are also several primary & secondary educational facilities within the area.

Principle 1:

Good design responds and contributes to its context. Context is the key natural and built features of an area, their relationship and the character they create when combined. It also includes social, economic, health and environmental conditions.

Responding to context involves identifying the desirable elements of an area’s existing or future character. Well-designed buildings respond to and enhance the qualities and identity of the area including the adjacent sites, streetscape and neighbourhood. Consideration of local context is important for all sites,

Context and Neighbourhood Character

Section B

Page 8: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

8

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

The main access of the site is from the Cudgegong Road. This existing road connecting the site to the Schofields road on the south and Guntawong Road on the north. There are 4 proposed local road for this development and 1 temporary access.

The roads width and location follow the indicative layout plan in Growth centre DCP Schedule 8 Riverstone. These 5 proposed roads divide the site into 3 future lots, 2 of them are zoned as medium density and the north east one is zoned as Cudgegong Reserve Land.

5 MIN WALKING RADIUS

15 MIN WALKING RADIUS

N

SUBJECT SITE

SCHOFIELDS RD

TALLAWONG RD

RIDGELINE DR

THE POND

S BLVD

OAK ST

BOUNDARY RD

WORCESTER RD

CUDGEGONG RD

MACQUARIE RD

ROUSE HILL

THE PONDSROUSE HILL

SCHOFIELDS

ROUSE RD

GORDON RD

HAMBLED

ON RD

CUDGEGONG ROAD STATION

ROUSE HILL ANGLICAN COLLEGE

INDICATIVE

SCHOOL

SITE

INDICATIVESCHOOLSITE

SECO

ND P

ONDS

CR

EEKFIRST PONDS CREEK

LOCAL CENTRE

RESERVED LAND

INFRASTRUCTURE/FACILITY/INSTITUTE

SPORTING FIELD

PUBLIC GREEN/LOCAL PARK

EMPLOYMENT/RETAIL

WATER COURSE

SUBJECT SITE

SUBURB BOUNDARIES

WALKING RADIUS

LOCAL ROAD

MAIN ROAD

SYDNEY METRO NORTHWEST

Context Map of Site Surrounding & Cudgegong Road Station Area

Page 9: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

9

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

As stated above, although the subject site is currently occupied by rural production and surrounded by small to medium size rural allotments, the future planning of the area has provided sufficient traffic solution with both public transport and local road connection. the existing and planned educational, recreational facilities can also support the increased population of the area. The subject site has proximity to the sustained growth of service and transport infrastructure and educational facilities, which provide the possibility for high density urban environment and demands for quality housing.

*Surrounding Built Form

The surrounding building context has different styles rural farmhouse which include colonial style to post war style. Most of houses have wide frontage towards to the road, long entry verandah, single story and hip roof.

The majority of these buildings are built by brick or weatherboard. There are also several tool sheds, barn or animal sheds with various of style and scale in the area.

Existing Surrounding Buildings (Sourced from Google Map) Proposed Surrounding Buildings (Sourced from submitted DA)

Proposed Surrounding Buildings (Sourced from submitted DA) Proposed Surrounding Buildings (Sourced from submitted DA)

Page 10: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

10

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Planning Context

The subject site is zoned R3 Medium density residential which is currently in accordance with the State Environmental Planning Policy (Sydney Region Growth Centres) 2006. Under the SEPP 2006, with consent, residential flat building is permissible on the subject site.

The land on the south, east, west and north-west of the site has the same zoning as the subject site, while on the north-east of the site are R2 low density residential area and SP2 infrastructure zoning.

The height limit of the site is 12 meters, which allows about 4 storey across the site, and a minimum density of 25 dwelling per hectare.

The overall planning context consistent with a low to medium density housing area with public recreational and infrastructure to support it. This allows the subject site to be developed with 4 storey residential flat buildings.

*Topography

The Cudgegong Road is generally slope to the south-east. And the site itself is fall to the south-east and the north-west from the middle with about 10 meters level change. The highest point is at the middle of the site at RL 70.0 meters, and the lowest point is on the south-east corner at around RL 60.0 meters.

The proposal tried to follow the sloping site to minimize the shadow casting to the south side public open space, and visual impact to the north proposed road. The storey arrangement of two separated buildings of Lot 1 differ by 1 storey height according to natural ground.

The overall stormwater design also utilizes the sloping site to guide the water to the south-west end of the site where the regional drainage channel located.

The future built form in the precinct is planned to be 3 to 6 storey multi-dwelling housing or residential flat buildings. There are several development proposals in the precinct with 4-6 storey residential flat buildings and underground parkings.

Furthermore, the transparent or light-weight architectural features such as louvers, pergolas and balustrades have been utilized in those developments to minimize the bulky looking visual obstruction.

Page 11: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

11

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Zoning Map, Sourced from Growth Centre Website

N

INFRASTRUCTURE/FACILITY/INSTITUTE

HIGH DENSITY RESIDENTIAL

MEDIUM DENSITY RESIDENTIAL

LOW DENSITY RESIDENTIAL

VERY LOW DENSITY RESIDENTIAL

TRAIN STATION ZONE

SPORTING FIELD

PUBLIC GREEN/LOCAL PARK

EMPLOYMENT/RETAIL/COMERCIAL

WATER COURSE

SUBJECT SITE

LOCAL ROAD

MAIN ROAD

LOT BOUNDARIES

SYDNEY METRO NORTHWEST

MACQUARIE RD

CUDGEGONG RD

TALLAWONG RD

ROUSE RD

OAK ST

SPORTING FIELD

ENVIRONMENTAL MANAGEMENT

ENVIRONMENTAL LIVING

WATER MANAGEMENT

WATER

MANAGEM

ENT

CUDGEGONG ROAD STATION ZONE

SCHOFIELDS RD

LOCAL CENTRE

ROUSE HILL ANGLICAN COLLEGE

SUBJECT SITE

CUDGEGONG ROAD STATIONFIRST PON

DS CR

EEK

RESERVED LAND

N

INFRASTRUCTURE/FACILITY/INSTITUTE

HIGH DENSITY RESIDENTIAL

MEDIUM DENSITY RESIDENTIAL

LOW DENSITY RESIDENTIAL

VERY LOW DENSITY RESIDENTIAL

TRAIN STATION ZONE

SPORTING FIELD

PUBLIC GREEN/LOCAL PARK

EMPLOYMENT/RETAIL/COMERCIAL

WATER COURSE

SUBJECT SITE

LOCAL ROAD

MAIN ROAD

LOT BOUNDARIES

SYDNEY METRO NORTHWEST

MACQUARIE RD

CUDGEGONG RD

TALLAWONG RD

ROUSE RD

OAK ST

SPORTING FIELD

ENVIRONMENTAL MANAGEMENT

ENVIRONMENTAL LIVING

WATER MANAGEMENT

WATER

MANAGEM

ENT

CUDGEGONG ROAD STATION ZONE

SCHOFIELDS RD

LOCAL CENTRE

ROUSE HILL ANGLICAN COLLEGE

SUBJECT SITE

CUDGEGONG ROAD STATIONFIRST PON

DS CR

EEK

RESERVED LAND

Page 12: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

12

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Built Form

As part of a greenfield development, the proposed residential flat buildings are aiming to present a contemporary style, articulated and sustainable design.

There are 2 individual lots divided by proposed local road, each with around 4600-4800 square meters area. the proposal has 4 separated 4 storey buildings located on these 2 lots. Each of these buildings are around 22-33 metres in depth and 51-52 meters in length.

Good design achieves a scale, bulk and height appropriate to the existing or desired future character of the street and surrounding buildings.

Good design also achieves an appropriate built form for a site and the building’s purpose in terms of building alignments, proportions, building type, articulation and the manipulation of building elements. Appropriate built form defines the public domain, contributes to the character of streetscapes and parks, including their views and vistas, and provides internal amenity and outlook.

Principle 2: Built Form and Scale

Subdivision Plan

Page 13: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

13

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

The size of this building allows all the units to have sufficient natural light and cross ventilation. All these perimeter blocks are surrounded by landscaped open spaces and communal gardens.

The design has in cooperated with the sun-shading devices and protruded balconies to articulate the façade, especially on the street frontage and rear sides of the façade, where to reduce its apparent bulk whilst providing high levels of amenity to all of the residential units and expressing an articulated architectural form to the surrounding future residents.

Furthermore, the proposal follows DCP building envelop control which includes the 6 meters setback from the street and side boundary, 4.5 meters setback for articulation elements or balconies.Thus, this proposal should have satisfied building separation to potential future adjacent residential flat building and reserved public recreational land.

The maximum building height is 12 meter from ground floor slab to roof top slab. This development proposes a 12 meters height building with skylight structure and 1.0 meter lift overrun on roof top which is not visible from street level.

Bird-eye view

Page 14: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

14

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

* Scale

As noted above, the future surrounding built form is comprised of a mix of low to medium rise residential buildings. The existing surrounding buildings are one to two storeys in height and most are detached houses.

The height of building plan in Growth Centre SEPP 2006 and the indicative layout plan from Growth Centre DCP shows consistent 12m (4 Storeys) height limit to southern side. The proposed development is aligned within the height limitation has been set in local control plans.

The overall building height should comply with the LEP control, while there are several minor encroachments with parapet wall and lift overruns. This non-compliance is due to the raised ground floor level which is intend to minimize the earth excavation, waste collection vehicle headroom & sloping site, and it should have no negative environmental effect or negative impact on adjoining property’s amenity.

Thus, the design enhances the design quality and streetscape quality by utilizing variety of materials, providing diverse building types with different facades, providing visual and acoustic privacy.

The encroachment of height limit is due to following reason:

1. The west part of the site has a steep slope towards to the west. The current scheme has stepped building to fit the natural ground line change, however, the part of the building still breaches the 12 meters height limit.2. The proposal allows 4.5 meters head clearance for waste collection trucks (medium ridge vehicles) as requested by Blacktown council. This results about 1.5 meters encroachment on height limitation on building A2 on lot B.

This non-compliance is considered to have no impact to the surrounding future built environment because:

1. The building habitable area complies with the height of building control (12m), with 4 levels of 3 meters slab to slab distance. The non-compliance does not increase any gross floor area and density.2. The design tried to incorporate with the slopping site by stepping the building with terrace open space for communal gardens on top of the building.3. The building has complied with the height limit on the street frontages (to the internal local roads/ half roads), so it has no impact on visual bulkiness.4. As shown on shadow diagrams, this non-compliance in height has very limited impact on solar access of the neighbouring sites.

Page 15: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

15

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

As stated before, the street front facades of building have been divided into smaller part and collage them to minimize the impact of its scale and bulk. The exterior expression line and timber like panel has similar form and scale as the future development dwellings next to the property which helps to preserve the continuity of the streetscape. The windows opening on the wall also has been emphasized by FC sheet frame to reduce the bulkiness of the street faced facades.

This scheme also proposed a different material for upper floor & lower floor facades to increase material articulation. It also visually reduced the building height and mass to avoid being unduly bulky to the street and adjoining developments.

The cross section of Lot 1

Page 16: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

16

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

The Street Facade Facing Tallawong Road

Aerial View From South

Page 17: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

17

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Planning Control

The subject site has total 20230 square meters (by survey) site area. It totals provides 201 units of residential dwelling, which result 99 units per hectare in density. This can well satisfy the density control which is minimum 25 units per hectare.

It is considered as an appropriate density which reflects the objective for medium density residential area. Firstly, the residential flat building complies with the permissible development for R3 medium density residential zoning. Furthers, the proposal complies with the building envelope to minimize the environmental impact to the potential future surrounding neighbours. Thirdly, it delivers the form and density that is desired for the area which located with proximity to future public transportation and major retail and community centres.

Principle 3: Density

Good design achieves a high level of amenity for residents and each apartment, resulting in a density appropriate to the site and its context.

Appropriate densities are consistent with the area’s existing or projected population. Appropriate densities can be sustained by existing or proposed infrastructure, public transport, access to jobs, community facilities and the environment.

The new development’s environmental impacts and amenity influence on adjoining sites have been minimised with strict compliance to the DCP setback requirement, and the design excellence is demonstrated in the built form and its architectural resolution in response to the current site conditions.

The relatively higher density also results no influence on the living condition for the future residents. The design utilizing passive solar control, high quality visual & acoustic protection solutions and sizeable common open space to ensure the amenity for the future residents.

Page 18: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

18

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Thermal Comfort & Energy Efficiency

Climatic responsive design has been applied to this proposal. Most of the units have been oriented north, east or west to gain direct solar access. As stated above, the building depth and separation are all comply with relevant controls that allow the sufficient sunlight exposure to the most of the units. There are 147 out of 201 units (73.1 %) can satisfy the 2 hours direct sunlight exposure requirement, which complies with the 70 % requirement. Furthermore, the passive thermal gain can be controlled by the adjustable louvers, pergolas. It significantly reduces the needs of heating, cooling and artificial lighting. An accompanying BASIX report outlines the specification of the sustainability methods that applied in this development.

There are 121 out of 201 units (60.2 %) have cross ventilation with operable opening on both side. It not only satisfies the need of fresh air but also increases the thermal comfort performance and energy consumption performance. All the habitable rooms have its own opening in forms of windows or sliding doors to ensure the natural lighting and air ventilation requirements, while all the toilets and kitchens have either natural ventilation or mechanical ventilation.

The development also proposed additional energy resources. It provides photovoltaic system with 30KW for common space lighting and ventilation power usage. This can reduce the building energy consumption and improve the sustainability.

Principle 4: Sustainability

Good design combines positive environmental, social and economic outcomes. Good sustainable design includes use of natural cross ventilation and sunlight for the amenity and liveability of residents and passive thermal design for ventilation, heating and cooling reducing reliance on technology and operation costs. Other elements include recycling and reuse of materials and waste, use of sustainable materials, and deep soil zones for groundwater recharge and vegetation.

Concept Image of ProposedSolar Panel

Page 19: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

19

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Concept Image of Proposed Decorative Privacy Screen

Concept Image of ProposedPrivacy Screen

Concept Image of ProposedSkylight

Concept Image of Proposed Window Fin Shade

Page 20: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

20

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Natural Cross Ventilation & Solar Access Indicative Diagrams

Natural Cross Ventilation & Solar Access Compliance Diagrams

Page 21: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

21

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Natural Cross Ventilation & Solar Access Indicative Diagrams

Natural Cross Ventilation & Solar Access Compliance Diagrams

Page 22: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

22

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Bike Rack for Accommodating - The Sustainable Lifestyle

*Waste Management

The demolition and construction waste will be managed and reused on site to maximize the recycle and minimize the potential pollution. Most of recyclable materials such as timber, plastic, glass, paper boxes, steel and aluminium will be encouraged to recycle on-site or by other specialized contractors. Those not recyclable materials such as masonry material, tiles or earth will be utilized for driveway base construction or as refill material for landscaping. The hazard material will be collected by qualified contractor.

Bin storage areas have been provided on the basement level for each lot with sufficient area for recycle bins and general wastes, separated bulky garbage rooms have been provided as well, loading bay has been designed next to the bin storage area for waste collection.

*Sustainable Lifestyle

This proposal provides bicycle racks and lockers which can store more than 72 bikes on site. These facilities will allow more sustainable traveling method to be used in future.

Page 23: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

23

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Environmental Effect

The development is proposed to be delivered with sufficient landscape area to improve the resident’s amenity and environmental sustainability performance. The majority of the ground floor open spaces are designed to be landscaped area. each lot has its own central courtyard, with deep soil area, raised planters, lawn and designed paved area. the ground floor community open space is the main communal space for residents. Native flora species are used to protect biological diversity. The building has been separated with the neighbours by screening vegetation, which will also protect the potential green corridors that go across the precinct.

The proposal has included raised planting beds with low-maintenance vegetation on ground floor private yards, which can reduce the privacy issue for ground floor residents. It also reduces the hard surface area in the building envelope to improve the passive stormwater retention performance. Low-water landscaping is also encouraged in this proposal to improve the water saving as well as the energy saving performance.

Principle 5: Landscape

Good design recognises that together landscape and buildings operate as an integrated and sustainable system, resulting in attractive developments with good amenity. A positive image and contextual fit of well-designed developments is achieved by contributing to the landscape character of the streetscape and neighbourhood.

Good landscape design enhances the development’s environmental performance by retaining positive natural features which contribute to the local context, co-ordinating water and soil management, solar access, micro-climate, tree canopy, habitat values, and preserving green networks. Good landscape design optimises usability, privacy and opportunities for social interaction, equitable access, respect for neighbours’ amenity, provides for practical establishment and long term management.

Page 24: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

24

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Recreational Open Spaces

Every individual unit has a private open space in the forms of balcony, terrace or court-yard. All private open spaces are equal or larger than the SEPP 65 requirement and DCP requirement. The ground floor units also have larger open space and deeper depth to enhance amenity and avoid privacy issues.

On the other hand, public recreational areas have been provided on ground floor central courtyard. Both two common open spaces and roof top terraces are located on the middle part of the site between two buildings in each lot. The entries of these communal open spaces are from lobby or side gate.

These communal open spaces are surrounded by screening plants to avoid the overlooking issue. The plants also provide natural sun shading for the opening spaces. Series of facilities are provided in these communal spaces, which include seating, barbeque grill units and children playgrounds. The boundaries are treated with fencing and hedges to provide more inclusive and surveilled area.

Indicative Landscape Plan

RL 76.00

RL 73.00

RL 73.00

RL 80.20

RL 80.20RL 77.20

RL 81.70

RL 81.70

LOT 14798 SQM

LOT 24660 SQM

LOT 36337 SQM

RL 77.20

PROPOSED ROAD 1 (9m-HALF ROAD)

PRO

POSED

RO

AD 4

PRO

POSE

D R

OAD

2 (9

m-H

ALF

RO

AD)

PROPOSED TEMPORARY ROAD

PRO

POSED

RO

AD 3

SITE BOUNDARY

SITE BOUNDARY

LOT BOUNDARY LOT BOUNDARY

SITE

BO

UNDA

RY

SITE

BO

UNDA

RY T

O C

UDG

EGO

NG R

OAD

LOT

BOUN

DARY

LOT BO

UNDARY

LOT BO

UNDARY

LOT BO

UNDARY

EASEMENT LINE

EASEMENT LINE

CU

DG

EGO

NG

RO

AD

Page 25: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

25

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Room Size & Layout

The unit design is following the apartment design guide. All the habitable rooms have 2.7 meters ceiling height, while the bathrooms and kitchens will be constructed with bulkheads and leave a 2.4 meters ceiling height.

The 1 bedroom units will have 50-57 square meters internal floor area; the 2 bedroom units will have 75-99 square meters internal floor area; and 3 bedroom units will have 95-112 square meters internal floor area, which all 3 types of units satisfy with the design criteria (50m2;70+5m2; 90+5m2). Every apartment has been fitted with a storage in the form of study room, pantry or cupboard which is also complied with the control.

All the bedrooms have minimum 3 meters in both direction and 9 square meters floor area, while the master bedrooms have minimum 3 meters in both direction and more than 10 square meters floor area. Furthers, all the bedrooms have more than 1.5 meters robe, while master bedrooms have either 1.8 meters built-in robe or walk-in robe.

All the 2 & 3 bedroom units have minimum 4.0 meters width for living area. Every private recreational open spaces are connected with the main living area to maximize the usage of both. All habitable areas are relatively shallow from glass to rear wall to decrease the need of artificial lighting. Most of balconies are separated to protect privacy. Moreover, some of master room can also access to the main private open space or a separated balcony.

Principle 6: Amenity

Good design positively influences internal and external amenity for residents and neighbours. Achieving good amenity contributes to positive living environments and resident wellbeing. Good amenity combines appropriate room dimensions and shapes, access to sunlight, natural ventilation, outlook, visual and acoustic privacy, storage, indoor and outdoor space, efficient layouts and service areas, and ease of access for all age groups and degrees of mobility.

Page 26: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

26

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Typical Unit Layout 1

*Thermal Comfort, Air & Natural Lighting

As stated above, 73.1% of units can receive two or more hours of sunlight between 9am to 3pm in the midwinter. North facing living rooms are maximised, and are relatively shallow from glass to rear wall. Most of north facing units and some of east and west facing units have controllable aluminium louvers or fixed timber-like louvers to improve the thermal comfort. All the balconies are covered by roof/ pergolas to reduce thermal gain from summer direct sunlight.

Over 60% of units have cross ventilation to maximize the energy efficiency and thermal comfort, mechanical ventilation system has been employed in bathrooms and kitchens to ensure the air quality. Furthers, all the external windows are openable for ventilation purpose. The design of the window size and shape balanced the needs of natural lighting and thermal comfort. All the living areas are connected to the private open space with a glazing sliding door which are about 6-8 sqm. And all the bedrooms have 3-5 sqm opening.

13 m²95 m²

A2-2F10

11 m²82 m²

A1-2F03

11 m²

53 m²A2-2F03

Typical Unit Layout 2

Typical Unit Layout 3

Page 27: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

27

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Acoustic Performance

The major noise impact is expected to come from the proposed road traffic. These transport corridor is direct adjacent to the proposed buildings. All the buildings are setback 6 meters to minimize the noise from traffic. The other potential noise source is the public park land on the east of the site. The parkland is separated to the lot with a 15.5 meters local road plus 6 meters building setback. Thus, this public space should have no dramatic noise impact to the proposed development.

*Privacy

The proposal is strictly complied with all setback control of the DCP which benefits the privacy performance. The building separation also complies with the apartment design guide. Furthers, thick vegetation around the ground floor units will screen the view from adjacent site and public access area. Thus, no significant privacy issue is expected on both eastern and western side and street fronts. The ground floor windows that face to the public open space have been screened by the planting as well. The 1800mm sill height windows are used to minimize the potential overlooking issue.

*Storage Area

The storage volume for each unit has either be allocated in basement cages or as a study/storage within the apartment units. Thus, 1 bedroom unit will have equal to or over 6m³ space of storage, 2 bedrooms unit will have equal to or over 8m³ and 3 bedrooms unit will have equal to or over 10m³ space of storage.

Page 28: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

28

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Crime Prevention Outcome

There are no apparent issues of safety and security in or around the subject site. The pedestrian has access to get in to the building direct from street. And vehicle will access the building from northern proposed local road.

Swipe card control access is provided for both main entrance, garden entrance, lift and car parking gate. For the visitors, video intercom system is adopted for main entrance and car parking area.

The streets, courtyard and balcony are benefited from visual surveillance from the living area and private open space. The residential accesses from proposed local roads or Tallawong Road are highly visible from the street and units to allow passive surveillance. The residential mail boxes are located in the entry lobby.

The vehicle accesses are located on middle of block for each lot. It improves the passive surveillance from the ground floor units and private yards.

Street lighting and landscape lighting improve the security for the residents and public domain. The CCTV monitoring system also will be also adopted to these areas.

Principle 7: Safety

Good design optimises safety and security, within the development and the public domain. It provides for quality public and private spaces that are clearly defined and fit for the intended purpose. Opportunities to maximise passive surveillance of public and communal areas promote safety.

A positive relationship between public and private spaces is achieved through clearly defined secure access points and well-lit and visible areas that are easily maintained and appropriate to the location and purpose.

Page 29: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

29

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Good design achieves a mix of apartment sizes, providing housing choice for different demographics, living needs and household budgets.

Well-designed apartment developments respond to social context by providing housing and facilities to suit the existing and future social mix. Good design involves practical and flexible features, including different types of communal spaces for a broad range of people, providing opportunities for social interaction amongst residents.

*Housing Diversity

3 types of unit have been provided in the project with certain variation in terms of layout and size. There are 4 of three bedroom units (2%), 148 of two bedroom units (73.6%) and 49 of one bedroom units (24.4%).

Sufficient car spaces have been provided as well as certain amount of bike lockers and racks to encourage the sustainable life style.

As the site has proximity to the future Cudgegong Road station and commercial shopping centre, the majority of the units are designed to be 2 bedroom units, which should attract small household types such as couple without child or with one child. All 3 bedroom units have a larger private outdoor space either on the terrace or ground floor private yard. It should encourage the medium size family to move into this higher density residential area with its high amenity and proximity to the future educational facilities. Most of 2 and 3 bedroom units are designed with a study room which can be adaptably used as a home office/ storage, which also potentially increase the housing diversity.

Principle 8: Housing Diversity and Social Interaction

Page 30: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

30

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Social Interaction

The proposed development provides for new residential supply within a priority growth centre, which is currently undergoing significant development. The area has been earmarked for an increase in density, which is encouraged by controls applicable to the site, and the future desired character for the precinct.

There are 24 adaptable units has been designed to provide housing for disabilities. These 24 adaptable units have been located in all 2 lots. There are 1 & 2 bedrooms choice for the adaptable units. These adaptable units are not only design for the disable people, it also encourage elderly residents to live in, which improves the local social interaction in terms of mixture of different aging group.

Adaptable Unit Variation PlansRefer to Architectural Plan Set

Page 31: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

31

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Adaptable Unit Variation PlansRefer to Architectural Plan Set

Page 32: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

32

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Streetscape & Townscape

As stated above, the proposal tries to express a modern architectural style which in consistency with those future development in the Area 20 Precinct, while keep similar form and scale to other proposed contemporary buildings within the precinct.

Moreover, the facade design has been articulated to improve the visual attraction and avoid to present a bulky form towards to the street. The balconies are projected to increase the layers on each façade. The window openings on the wall have been emphasized by rendered feature cladding to divide the facade. The transparent material has been used for balustrade to avoid over bulky looking. Vegetation has been used to create a soften separation between the buildings.

Principle 9: Aesthetics

Good design achieves a built form that has good proportions and a balanced composition of elements, reflecting the internal layout and structure. Good design uses a variety of materials, colours and textures. The visual appearance of well-designed apartment development responds to the existing or future local context, particularly desirable elements and repetitions of the streetscape.

Render Image

Page 33: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

33

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Material Indicative Sample

Material Indicative Perspective

Page 34: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

34

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

*Materiality

The use of materials on architectural features such as blade walls, framed exterior window, grooved panel cladding, louvers and glass/metal balustrade provide a rich character that articulate the facade, with a high degree of refinement and longevity. The design whilst contemporary in nature fits in with the developments in the area through its relevant and moderated material palette.

Bright, soft and warm colours have been chosen for the majority of the facades to increase the visual tension. The darker colour has been used for top & ground level of the building to visually ‘setback’ those levels. Brighter colour that used on middle levels with architectural geometry elements to minimize the bulky feeling of the building. The warm colour material such as terracotta cladding can balance the large amount of cold colour rendering and refine the private open spaces.

Furthermore, the contrast between the fine grain texture such as grooved cladding/ bricks and large area painted surface enriches the facades. The materials and finishes used throughout are robust and designed to withstand the elements whilst maintaining the character of the local area which exists within the locality. The intent of the design works on both a macro and micro level, the planning of the site and the detailing of the finishes will ensure and provide a high quality example for future development in this area.

*Overall Design Principle

The building is designed to be symmetrical on both layout and façade. The majority of the façade features follow this pattern while some of the architectural elements such as terracotta cladding and privacy panels have asymmetrical design. This design is the outcome of considering the size of the parcel, the ratio of the width and depth of the land and the appropriate unit layout. And it should also reflect the future characters of this medium density housing community within the Area 20 Precinct.

Page 35: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

35

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Conclusion:

This statement discussed the architectural design performance for the development on 105 Cudgegong Road in accordance with 9 principles that stated in the SEPP65 Design Quality of Residential Flat Building. The proposal endeavour to comply with all criteria that set out in the Apartment Design Guide, while it tries to deliver a quality and responsive design for this growing future residential precinct.

It is our opinion that this proposal achieves all the controls and guidance in the Sepp 65 with exception of some minor non-compliances which have minimal impact on the objectives.

Section C

Page 36: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

36

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Appendix ACompliance Table

Page 37: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

37

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 38: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

38

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 39: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

39

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 40: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

40

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 41: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

41

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 42: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

42

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 43: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

43

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 44: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

44

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 45: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

45

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 46: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

46

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 47: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

47

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Page 48: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

48

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Appendix BUnits Numeric Table - Lot 1

Solar Access   0‐2hrs  from 9am ‐ 3pm

Solar Access   2hrs  from 9am ‐ 3pm

Cross Ventilation

Habitable Room 

Depth(m)Unit Size(m²) Balcony 

Size(m²)Interior 

Storage(m²)Basement Storage(m²) Total(m³) Requried(m³)

A1‐LGF01 No Yes Yes 4.19 84 17 8.2 0 21.32 8 A1‐LGF01A1‐LGF02 No No No 7.63 76 19 1.9 2 9.14 8 A1‐LGF02A1‐LGF03 No No No 7.75 112 26 4.8 0 12.48 10 A1‐LGF03A1‐LGF04 No No No 8.74 51 13 1.3 2 7.58 6 A1‐LGF04A1‐LGF05 No No Yes 4.95 75 10 1.9 2 9.14 8 A1‐LGF05A1‐GF01 No Yes No 4.34 50 9 0.7 2 6.02 6 A1‐GF01A1‐GF02 No Yes No 4.34 50 9 0.7 2 6.02 6 A1‐GF02A1‐GF03 No Yes Yes 7.93 82 11 7.1 0 18.46 8 A1‐GF03A1‐GF04 No Yes No 7 51 8 2.2 2 9.92 6 A1‐GF04A1‐GF05 No Yes Yes 7.95 81 12 1.9 2 9.14 8 A1‐GF05A1‐GF06 No No No 7.63 81 20 4.4 0 11.44 8 A1‐GF06A1‐GF07 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐GF07A1‐GF08 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐GF08A1‐GF09 No No No 8.08 78 10 0 5 10.5 8 A1‐GF09A1‐GF10 No No Yes 3.73 75 10 0.9 4 10.74 8 A1‐GF10A1‐GF11 No Yes Yes 7.28 75 10 1.5 3 10.2 8 A1‐GF11A1‐GF12 No Yes No 7.38 77 10 3.3 0 8.58 8 A1‐GF12A2‐GF01 Yes No Yes 4.25 55 8 1.7 2 8.62 6 A2‐GF01A2‐GF02 Yes No Yes 5.68 83 10 7.2 0 18.72 8 A2‐GF02A1‐1F01 No Yes No 4.34 50 9 0.7 3 8.12 6 A1‐1F01A1‐1F02 No Yes No 4.34 50 9 0.7 3 8.12 6 A1‐1F02A1‐1F03 No Yes Yes 7.93 82 11 7.1 0 18.46 8 A1‐1F03A1‐1F04 No Yes No 7 51 8 2.2 2 9.92 6 A1‐1F04A1‐1F05 No Yes Yes 7.95 81 12 1.9 2 9.14 8 A1‐1F05A1‐1F06 No No No 7.63 81 20 4.4 0 11.44 8 A1‐1F06A1‐1F07 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐1F07A1‐1F08 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐1F08A1‐1F09 No No No 8.08 78 10 1.4 3 9.94 8 A1‐1F09A1‐1F10 No No Yes 3.73 75 10 0.8 4 10.48 8 A1‐1F10A1‐1F11 No Yes Yes 7.28 75 10 1.5 2 8.1 8 A1‐1F11A1‐1F12 No Yes No 7.38 77 10 3.3 0 8.58 8 A1‐1F12A2‐1F01 Yes No No 2.38 55 17 7.4 0 19.24 6 A2‐1F01A2‐1F02 No Yes Yes 8.77 95 10 5.5 0 14.3 8 A2‐1F02A2‐1F03 No Yes No 7.15 50 10 4.8 0 12.48 6 A2‐1F03A2‐1F04 No Yes No 7 80 11 4.9 0 12.74 8 A2‐1F04A2‐1F05 No Yes Yes 6.65 53 8 2.8 0 7.28 6 A2‐1F05A2‐1F06 No Yes No 8.01 91 31 3.9 0 10.14 8 A2‐1F06A2‐1F07 No Yes Yes 8.77 97 26 8.5 0 22.1 8 A2‐1F07A2‐1F08 No Yes Yes 8.1 92 32 8.5 0 22.1 8 A2‐1F08A2‐1F09 No Yes No 8.74 90 31 5.4 0 14.04 8 A2‐1F09A2‐1F10 No Yes Yes 8.77 75 12 1.9 2 9.14 8 A2‐1F10A2‐1F11 Yes No No 5.05 75 10 1.5 2 8.1 8 A2‐1F11A2‐1F12 No No Yes 5.16 80 9 5.8 0 15.08 8 A2‐1F12A2‐1F13 No Yes Yes 3.67 52 14 1.7 2 8.62 6 A2‐1F13A2‐1F14 No Yes No 6.17 53 14 4.6 0 11.96 6 A2‐1F14A1‐2F01 No Yes No 4.34 50 9 0.7 2 6.02 6 A1‐2F01A1‐2F02 No Yes No 4.34 50 9 0.7 2 6.02 6 A1‐2F02A1‐2F03 No Yes Yes 7.93 82 11 7.1 0 18.46 8 A1‐2F03A1‐2F04 No Yes No 7 51 8 2.2 2 9.92 6 A1‐2F04A1‐2F05 No Yes Yes 7.95 81 12 1.9 2 9.14 8 A1‐2F05A1‐2F06 No No No 7.63 81 20 4.4 0 11.44 8 A1‐2F06A1‐2F07 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐2F07A1‐2F08 No Yes Yes 8.74 80 10 2 2 9.4 8 A1‐2F08A1‐2F09 No No No 8.08 78 10 1.4 3 9.94 8 A1‐2F09A1‐2F10 No No Yes 3.73 75 10 0.8 4 10.48 8 A1‐2F10A1‐2F11 No Yes Yes 7.28 75 10 1.5 3 10.2 8 A1‐2F11A1‐2F12 No Yes No 7.38 77 10 3.3 0 8.58 8 A1‐2F12A2‐2F01 Yes No No 5.7 75 10 7.4 0 19.24 8 A2‐2F01A2‐2F02 No Yes Yes 8.74 93 10 5.5 0 14.3 8 A2‐2F02A2‐2F03 No Yes No 6.5 53 11 3.6 0 9.36 6 A2‐2F03A2‐2F04 No Yes No 6.5 77 10 4.9 0 12.74 8 A2‐2F04A2‐2F05 No Yes Yes 4.25 77 12 0 6 12.6 8 A2‐2F05A2‐2F06 No Yes No 8.01 91 17 3.9 0 10.14 8 A2‐2F06A2‐2F07 No Yes Yes 8.65 89 13 0.8 4 10.48 8 A2‐2F07A2‐2F08 No Yes Yes 7.54 89 11 8.5 0 22.1 8 A2‐2F08A2‐2F09 No Yes No 6.05 85 17 1.3 3 9.68 8 A2‐2F09A2‐2F10 No Yes Yes 7.57 95 13 2.8 2 11.48 10 A2‐2F10A2‐2F11 Yes No No 5.05 75 10 1.5 3 10.2 8 A2‐2F11A2‐2F12 No No Yes 5.16 80 10 5.8 0 15.08 8 A2‐2F12A2‐2F13 No Yes Yes 3.67 52 8 1.7 2 8.62 6 A2‐2F13A2‐2F14 No Yes No 6.17 53 8 4.6 0 11.96 6 A2‐2F14A1‐3F01 No Yes Yes 7 51 8 2.2 2 9.92 6 A1‐3F01A1‐3F02 No Yes Yes 7.93 82 11 7.1 0 18.46 8 A1‐3F02A1‐3F03 No Yes Yes 4.34 50 9 0.7 3 8.12 6 A1‐3F03A1‐3F04 No Yes Yes 4.34 50 9 0.7 3 8.12 6 A1‐3F04A1‐3F05 No Yes Yes 7.09 51 9 4 0 10.4 6 A1‐3F05A1‐3F06 No Yes Yes 7.09 51 9 4 0 10.4 6 A1‐3F06A1‐3F07 No Yes Yes 7.38 77 10 3.3 0 8.58 8 A1‐3F07A1‐3F08 No Yes Yes 7.68 78 10 6.1 0 15.86 8 A1‐3F08A2‐3F01 Yes No No 5.7 75 10 7.4 0 19.24 8 A2‐3F01A2‐3F02 No Yes Yes 8.74 93 10 5.5 0 14.3 8 A2‐3F02A2‐3F03 No Yes No 6.5 53 11 3.6 0 9.36 6 A2‐3F03A2‐3F04 No Yes No 6.5 77 10 4.9 0 12.74 8 A2‐3F04A2‐3F05 No Yes Yes 4.25 77 12 0 6 12.6 8 A2‐3F05A2‐3F06 No Yes No 8.01 91 17 3.9 0 10.14 8 A2‐3F06A2‐3F07 No Yes Yes 8.65 89 13 0.8 4 10.48 8 A2‐3F07A2‐3F08 No Yes Yes 7.54 89 11 8.5 0 22.1 8 A2‐3F08A2‐3F09 No Yes No 6.05 85 17 1.3 3 9.68 8 A2‐3F09A2‐3F10 No Yes Yes 7.57 95 13 2.8 2 11.48 10 A2‐3F10A2‐3F11 Yes No No 5.05 75 10 1.5 2 8.1 8 A2‐3F11A2‐3F12 No No Yes 5.16 80 10 5.8 0 15.08 8 A2‐3F12A2‐3F13 No Yes Yes 3.67 52 8 1.7 2 8.62 6 A2‐3F13A2‐3F14 No Yes No 6.17 53 8 4.6 0 11.96 6 A2‐3F14A2‐4F01 No Yes Yes 5.7 75 10 7.4 0 19.24 8 A2‐4F01A2‐4F02 No Yes Yes 8.74 93 10 5.5 0 14.3 8 A2‐4F02A2‐4F03 No Yes Yes 6.5 53 11 3.6 0 9.36 6 A2‐4F03A2‐4F04 No Yes Yes 6.5 77 10 4.9 0 12.74 8 A2‐4F04A2‐4F05 No Yes Yes 4.25 77 12 0 5 10.5 8 A2‐4F05A2‐4F06 No Yes Yes 8.01 91 17 3.9 0 10.14 8 A2‐4F06A2‐4F07 No Yes Yes 8.65 89 13 0.8 5 12.58 8 A2‐4F07A2‐4F08 No Yes Yes 7.54 89 11 8.5 0 22.1 8 A2‐4F08A2‐4F09 No Yes Yes 6.05 85 17 1.3 4 11.78 8 A2‐4F09A2‐4F10 No Yes Yes 7.57 95 13 2.8 2 11.48 10 A2‐4F10A2‐4F11 No Yes Yes 5.05 75 10 1.5 2 8.1 8 A2‐4F11A2‐4F12 No Yes Yes 53 8 4.6 0 11.96 6 A2‐4F12

Sum 8/105(7.6%) 81/105(77%) 63/105(60%) 8.77 MAX 7764 1262 354.4 148 1232.24 SumCompliance Yes Yes Yes No Yes Yes Yes Yes Yes Compliance

1 Bedroom2 Bedroom3 Bedroom

SEPP 65 Numeric Compliance TableProject Adress:

Unit Number:

Lot 1 ‐ 105 Cudgegong Road, Rouse Hill

Unit NO.

105 of 201 Architect:

Non‐ComplianceCompliance

Unit NO.

Note: This table is prepared by TSA Dreamscape  for the DA submission for 105 Cudgegong Road, Rouse Hill, 201 units residential flat building development, should read accompany with SEPP 65 report and architectural drawings.

Compliance Storage Area

Page 49: SEPP No.65: DESIGN 105 CUDGEGONG ROAD, ROUSE HILL VERIFICATION … · 65 –Design Quality of Residential Flat Building with exception of some minor non-compliances which have no

49

DREAMSCAPESARCHITECTS MULTI-RESIDENTIAL DEVELOPMENT

PROJECT NO. DSS-2017-01

95 TALLAWONG ROAD, ROUSE HILL NSW

Appendix BUnits Numeric Table - Lot 2

Solar Access   0‐2hrs  from 9am ‐ 3pm

Solar Access   2hrs  from 9am ‐ 3pm

Cross Ventilation

Habitable Room 

Depth(m)Unit Size(m²) Balcony 

Size(m²)Interior 

Storage(m²)Basement Storage(m²) Total(m³) Requried(m³)

B1‐GF01 Yes No Yes 5.81 53 27 3.2 0 8.32 6 B1‐GF01B1‐GF02 No Yes Yes 5.56 83 49 5.2 0 13.52 8 B1‐GF02B1‐GF03 No Yes Yes 4.7 79 43 0 4 8.4 8 B1‐GF03B1‐GF04 No Yes No 7.7 84 19 4.1 0 10.66 8 B1‐GF04B1‐GF05 No Yes No 8.71 57 14 2.8 0 7.28 6 B1‐GF05B1‐GF06 No Yes Yes 8.45 89 26 1.8 4 13.08 8 B1‐GF06B1‐GF07 No Yes Yes 8.45 90 34 1.8 3 10.98 8 B1‐GF07B1‐GF08 No Yes No 6.08 85 17 6.1 0 15.86 8 B1‐GF08B1‐GF09 No Yes Yes 7.23 82 11 3.2 0 8.32 8 B1‐GF09B1‐GF10 No No No 5.6 50 19 2.2 2 9.92 8 B1‐GF10B1‐GF11 Yes No Yes 6.19 75 15 11 0 28.6 8 B1‐GF11B1‐GF12 Yes No Yes 7.52 52 13 1.8 2 8.88 8 B1‐GF12B2‐GF01 No Yes Yes 6.57 53 20 1.7 2 8.62 8 B2‐GF01B2‐GF02 No Yes Yes 6.58 79 28 3.7 0 9.62 8 B2‐GF02B2‐GF03 No Yes Yes 4.7 78 80 1 3 8.9 8 B2‐GF03B2‐GF04 Yes No No 7.8 80 83 1.8 2 8.88 8 B2‐GF04B2‐GF05 Yes No No 7.75 54 27 3.6 0 9.36 6 B2‐GF05B2‐GF06 Yes No Yes 8.71 96 42 3.7 0 9.62 8 B2‐GF06B2‐GF07 No Yes Yes 8.05 99 39 10.8 0 28.08 8 B2‐GF07B2‐GF08 No Yes No 8.2 77 37 1.7 2 8.62 8 B2‐GF08B2‐GF09 No Yes Yes 4.97 51 20 1.9 2 9.14 6 B2‐GF09B2‐GF10 No No No 4.81 52 23 1.1 2 7.06 6 B2‐GF10B2‐GF11 Yes No Yes 8.35 77 42 2.1 2 9.66 8 B2‐GF11B2‐GF12 Yes No No 7.89 92 29 8.4 0 21.84 8 B2‐GF12B1‐1F01 No Yes No 8.71 56 8 2.9 0 7.54 6 B1‐1F01B1‐1F02 No Yes No 7.45 83 10 4.1 0 10.66 8 B1‐1F02B1‐1F03 No Yes Yes 4.4 78 14 0.9 4 10.74 8 B1‐1F03B1‐1F04 No Yes Yes 5.26 83 10 5.2 0 13.52 8 B1‐1F04B1‐1F05 Yes No No 6.95 78 8 1.3 3 9.68 8 B1‐1F05B1‐1F06 No Yes Yes 7.95 87 10 1.8 2 8.88 8 B1‐1F06B1‐1F07 No Yes Yes 7.95 88 10 1.8 2 8.88 8 B1‐1F07B1‐1F08 Yes No No 7.14 78 10 2.5 1 8.6 8 B1‐1F08B1‐1F09 Yes No Yes 6.19 75 9 1.1 3 9.16 8 B1‐1F09B1‐1F10 No No No 5.6 50 6 2.2 1 7.82 6 B1‐1F10B1‐1F11 No Yes Yes 7.24 82 8 3.2 0 8.32 8 B1‐1F11B1‐1F12 No Yes No 6.08 85 11 6.1 0 15.86 8 B1‐1F12B2‐1F01 Yes No No 7.5 53 7 3.6 0 9.36 6 B2‐1F01B2‐1F02 Yes No No 7.81 80 11 1.8 2 8.88 8 B2‐1F02B2‐1F03 No Yes Yes 4.7 78 12 1 3 8.9 8 B2‐1F03B2‐1F04 No Yes Yes 6.58 84 12 8.9 0 23.14 8 B2‐1F04B2‐1F05 No Yes No 8.71 85 12 5.9 0 15.34 8 B2‐1F05B2‐1F06 Yes No Yes 8.71 96 9 3.7 0 9.62 8 B2‐1F06B2‐1F07 No Yes Yes 8.05 99 12 10.8 0 28.08 8 B2‐1F07B2‐1F08 No Yes No 8.2 80 11 8 0 20.8 8 B2‐1F08B2‐1F09 No Yes Yes 6.48 77 16 0.4 4 9.44 8 B2‐1F09B2‐1F10 No No No 4.1 50 8 1.1 2 7.06 6 B2‐1F10B2‐1F11 Yes No Yes 8.35 77 9 2.1 2 9.66 8 B2‐1F11B2‐1F12 Yes No No 7.89 92 11 8.4 0 21.84 8 B2‐1F12B1‐2F01 No Yes No 8.71 56 8 2.9 0 7.54 6 B1‐2F01B1‐2F02 No Yes No 7.45 83 10 4.1 0 10.66 8 B1‐2F02B1‐2F03 No Yes Yes 4.4 78 14 0.9 4 10.74 8 B1‐2F03B1‐2F04 No Yes Yes 5.26 83 10 5.2 0 13.52 8 B1‐2F04B1‐2F05 Yes No No 6.95 78 8 1.3 3 9.68 8 B1‐2F05B1‐2F06 No Yes Yes 7.95 87 10 1.8 2 8.88 8 B1‐2F06B1‐2F07 No Yes Yes 7.95 88 10 1.8 2 8.88 8 B1‐2F07B1‐2F08 Yes No No 7.14 78 10 2.5 1 8.6 8 B1‐2F08B1‐2F09 Yes No Yes 6.19 75 9 1.1 3 9.16 8 B1‐2F09B1‐2F10 No No No 5.6 50 6 2.2 1 7.82 6 B1‐2F10B1‐2F11 No Yes Yes 7.24 82 8 3.2 0 8.32 8 B1‐2F11B1‐2F12 No Yes No 6.08 85 11 6.1 0 15.86 8 B1‐2F12B2‐2F01 Yes No No 7.5 53 7 3.6 0 9.36 6 B2‐2F01B2‐2F02 Yes No No 7.81 80 11 1.8 2 8.88 8 B2‐2F02B2‐2F03 No Yes Yes 4.7 78 12 1 3 8.9 8 B2‐2F03B2‐2F04 No Yes Yes 6.58 84 12 8.9 0 23.14 8 B2‐2F04B2‐2F05 No Yes No 8.71 85 12 5.9 0 15.34 8 B2‐2F05B2‐2F06 Yes No Yes 8.71 96 9 3.7 0 9.62 8 B2‐2F06B2‐2F07 No Yes Yes 8.05 99 12 10.8 0 28.08 8 B2‐2F07B2‐2F08 No Yes No 8.2 80 11 8 0 20.8 8 B2‐2F08B2‐2F09 No Yes Yes 6.48 77 16 0.4 4 9.44 8 B2‐2F09B2‐2F10 No No No 4.1 50 8 1.1 2 7.06 6 B2‐2F10B2‐2F11 Yes No Yes 8.35 77 9 2.1 2 9.66 8 B2‐2F11B2‐2F12 Yes No No 7.89 92 11 8.4 0 21.84 8 B2‐2F12B1‐3F01 No Yes No 8.71 56 8 2.9 0 7.54 6 B1‐3F01B1‐3F02 No Yes No 7.45 83 10 4.1 0 10.66 8 B1‐3F02B1‐3F03 No Yes Yes 4.4 78 14 0.9 3 8.64 8 B1‐3F03B1‐3F04 No Yes Yes 5.26 83 10 5.2 0 13.52 8 B1‐3F04B1‐3F05 No Yes Yes 6.95 78 9 1.3 3 9.68 8 B1‐3F05B1‐3F06 No Yes Yes 7.95 89 8 1.8 2 8.88 8 B1‐3F06B1‐3F07 No Yes Yes 7.95 90 8 1.8 2 8.88 8 B1‐3F07B1‐3F08 No Yes Yes 7.14 78 10 2.5 2 10.7 8 B1‐3F08B1‐3F09 No Yes Yes 6.19 75 9 1.1 3 9.16 8 B1‐3F09B1‐3F10 No Yes Yes 5.6 50 6 2.2 1 7.82 6 B1‐3F10B1‐3F11 No Yes Yes 7.24 82 8 3.2 0 8.32 8 B1‐3F11B1‐3F12 No Yes No 6.08 85 11 6.1 0 15.86 8 B1‐3F12B2‐3F01 No Yes Yes 7.5 53 7 3.6 0 9.36 6 B2‐3F01B2‐3F02 No Yes Yes 7.81 80 11 1.8 3 10.98 8 B2‐3F02B2‐3F03 No Yes Yes 4.7 78 12 1 4 11 8 B2‐3F03B2‐3F04 No Yes Yes 6.58 84 12 8.9 0 23.14 8 B2‐3F04B2‐3F05 No Yes No 8.71 85 12 5.9 0 15.34 8 B2‐3F05B2‐3F06 No Yes Yes 8.71 96 9 3.7 0 9.62 8 B2‐3F06B2‐3F07 No Yes Yes 8.05 99 12 10.8 0 28.08 8 B2‐3F07B2‐3F08 No Yes No 8.2 80 11 8 0 20.8 8 B2‐3F08B2‐3F09 No Yes Yes 6.48 77 16 0.4 4 9.44 8 B2‐3F09B2‐3F10 No Yes Yes 4.1 50 8 1.1 2 7.06 6 B2‐3F10B2‐3F11 No Yes Yes 8.35 77 9 2.1 2 9.66 8 B2‐3F11B2‐3F12 No Yes Yes 7.89 92 11 8.4 0 21.84 8 B2‐3F12

Sum 24/96(25%) 66/96(69%) 58/96(60%) 8.71 MAX 7401 1486 351.1 119 1162.76 SumCompliance Yes Yes Yes No Yes Yes Yes Yes Yes Compliance

1 Bedroom2 Bedroom3 Bedroom

SEPP 65 Numeric Compliance TableProject Adress: Lot 2 ‐ 105 Cudgegong Road, Rouse Hill

Unit Number: 96 of 201 Architect:

Note: This table is prepared by TSA Dreamscape  for the DA submission for 105 Cudgegong Road, Rouse Hill, 201 units residential flat building development, should read accompany with SEPP 65 report and architectural drawings.

ComplianceNon‐Compliance

Unit NO.

Compliance Storage Area

Unit NO.