8
CC-1 CC-1 CC-1 CC-1 CC-1 DIVISION OF PITTCON ARCHITECTURAL METALS, LLC Column Column Column Column Column Covers Covers Covers Covers Covers Column Column Column Column Column Covers Covers Covers Covers Covers Series 1500 Series 1500 Series 1500 Series 1500 Series 1500 Series 1500 Series 1500 Series 1500 Series 1500 Series 1500

Ser 1500 Column v6 - Pittcon Industries · 3 Series 1500-Options Optional Ceiling Trim Rings Acoustical or Drywall Optional Base or Top Reveals are Available in the Same Material

Embed Size (px)

Citation preview

CC-1CC-1CC-1CC-1CC-1

DIVISION OF PITTCON ARCHITECTURAL METALS, LLC

ColumnColumnColumnColumnColumnCoversCoversCoversCoversCoversColumnColumnColumnColumnColumnCoversCoversCoversCoversCoversSeries 1500Series 1500Series 1500Series 1500Series 1500Series 1500Series 1500Series 1500Series 1500Series 1500

22222

Maximum 48" Dia (1.219 M) Config. 'A'Maximum 36" Dia (914.4 mm) Config. 'B'

Maximum 90" Dia (2.286 M)Available Wider with Addition of Flat Panels

FullColumn Cover

Maximum 55" Dia (1.397 M)

Full ColumnCover with3 JointsEllipticalColumn Cover

Maximum 72" Width (1.829 M)Wider w/Additional Flat Panels Consult Factory

Race-Track OvalColumn CoverExtended HalfColumn Cover

Three Quarter &Partial ColumnCovers

Config. 'A'

Config. 'B'

Maximum 18"36" Dia (1.397 M)

Half RoundColumn Cover(Wall Mount)Quarter RoundColumn Cover(Wall Mount)

Series 1500-DetailsSeries 1500-DetailsSeries 1500-DetailsSeries 1500-DetailsSeries 1500-Details

Square, Rectangular,or OctagonalColumn Cover

Backing Material toControl Oil-Canning

Consult FactoryMinimum 12" Dia (304.8 mm) < 12' tallMinimum 16" Dia (406.4 mm) > 12' tallMaximum 36" (914.4 mm) Dia

Minimum 6" R (152.4 mm) < 12' tallMinimum 8" R (203.2 mm) > 12' tallMaximum 36" R (914.4 mm)

2-5/8"(66.7 mm)Typ

Note:Note:Note:Note:Note:Minimum Diameter of Column Covers is Dependant upon Type of Material used (Aluminum, Stainless Steel, etc.) SomeMinimum Diameter of Column Covers is Dependant upon Type of Material used (Aluminum, Stainless Steel, etc.) SomeMinimum Diameter of Column Covers is Dependant upon Type of Material used (Aluminum, Stainless Steel, etc.) SomeMinimum Diameter of Column Covers is Dependant upon Type of Material used (Aluminum, Stainless Steel, etc.) SomeMinimum Diameter of Column Covers is Dependant upon Type of Material used (Aluminum, Stainless Steel, etc.) SomeConfigurations may Require a 14" Minimum Diameter up to 12', and 18" Diameter Above. For More Information, Consult Factory.Configurations may Require a 14" Minimum Diameter up to 12', and 18" Diameter Above. For More Information, Consult Factory.Configurations may Require a 14" Minimum Diameter up to 12', and 18" Diameter Above. For More Information, Consult Factory.Configurations may Require a 14" Minimum Diameter up to 12', and 18" Diameter Above. For More Information, Consult Factory.Configurations may Require a 14" Minimum Diameter up to 12', and 18" Diameter Above. For More Information, Consult Factory.

33333

Series 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsOptional Ceiling Trim RingsAcoustical or Drywall

Optional Base or Top Reveals are Availablein the Same Material as the Column Coveror in a Contrasting Finish.

1/2"(12.7 mm)Typ4"(101.6 mm)Typ

The Snap-in RevealStrip Locks the Col-umn Cover InstallationFins into the PostChannel. Typical Re-veal size is 1/2" x 1/2"

Top and Mid-Level Re-veals can be Either ofthe Open or ClosedVariety. Closed Re-veals are Sealed withNeoprene Rubber Bat-tens Top and Bottom

The SERIES 1500 SIDE-LOCKTM Column CoverComes with a Recessed Reveal Joint forApplications Where a Decorative VerticalReveal is Desired. It can be Designed with aLarge Variety of Optional Details.

44444Rubber Bumper Rails are Available in Stan-dard Sizes of 1" dia and 2" dia. They Come in18 Standard Colors.

Series 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-Options

The SERIES 1500 SNAP-FORM® Column CoverComes with a Soft 'V' Joint for Those ApplicationsWhere a Vertical Reveal is not Desired. Column CoversColumn CoversColumn CoversColumn CoversColumn CoversAre Available up to 16' in Height in Single Lengths.Are Available up to 16' in Height in Single Lengths.Are Available up to 16' in Height in Single Lengths.Are Available up to 16' in Height in Single Lengths.Are Available up to 16' in Height in Single Lengths.Stacking Joints Allow for Almost Unlimited Height.Stacking Joints Allow for Almost Unlimited Height.Stacking Joints Allow for Almost Unlimited Height.Stacking Joints Allow for Almost Unlimited Height.Stacking Joints Allow for Almost Unlimited Height.

Neoprene RubberBumper Rails in Vari-ous Colors can be usedto Protect The Finishand Act as a Decora-tive Feature

The Hairline Joint Be-tween Each StackedSection is Backed by aFactory Installed Align-ment Plate

Although Column Cov-Although Column Cov-Although Column Cov-Although Column Cov-Although Column Cov-ers Are Available upers Are Available upers Are Available upers Are Available upers Are Available upto 16' in Height, Theto 16' in Height, Theto 16' in Height, Theto 16' in Height, Theto 16' in Height, TheIntroduction of Stack-Introduction of Stack-Introduction of Stack-Introduction of Stack-Introduction of Stack-ing Joints Allows foring Joints Allows foring Joints Allows foring Joints Allows foring Joints Allows forAlmost any Height De-Almost any Height De-Almost any Height De-Almost any Height De-Almost any Height De-sired.sired.sired.sired.sired. Each StackedSection is Anchoredto the Posts viaSafety Retainer Clipsin Two Locations

55555Race-Track Oval Column Covers can be Designedto Accommodate Various Special Field Condi-tions Such as Those Shown Here. It is Perfectfor Those Conditions Where Concealing HVAC orElectrical Services is Required.

Series 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-Options

Special Installation Detail for Grill TrackOpening. (Grill Track by Others)These Options, as well as Most Others, areAvailable with all of Our Column Cover De-signs. Please Consult with the Factory forYour Particular Design Needs.

Optional Telescoping Top Reveal RingAllows for Height Adjustment

1" (25.4 mm) Typ1/2" (12.7 mm) Typ

Race-Track Oval DesignAllows for Various Types of Access DoorInstallations, Such as Fire ExtinguisherCabinets, Electrical Access Doors, Etc.

66666

Column Covers can be Combined withBeam Covers to Completely Enclose allExisting Structural Members. Joints canbe Configured in Different Manners toAllow for Alignment and Decorative Con-siderations.

Column Cover can beNotched Either in the Fieldor at the Factory. BeamCover is Then Sleeved tothe Side of the Cover asShown and Secured withColor Matched Screws

Series 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-OptionsSeries 1500-Options

Sleeve can be Fin-ished to MatchBeam Cover in Or-der to Act as anAdjustable Reveal

These Options, as well as Most Others, areAvailable with all of Our Column Cover De-signs. Please Consult with the Factory forYour Particular Design Needs.

In View Shown, Beam Cover is Mounted UsingVisible Fasteners (Screws) Top & Bottom.Alternate Mounting Options are AvailableIncluding SIDE-LOCKTM and SNAP-FORM®Joints.

77777

Series 1500-FinishesSeries 1500-FinishesSeries 1500-FinishesSeries 1500-FinishesSeries 1500-FinishesColumn Covers are Available in the Following Material and Finishes:Aluminum in .090" Standard Thickness (2.3 mm)

• Pattern Metal finish with Clear or Semi-transparent Clear-coat (see Pattern Metal brochure for details)• Painted in PPG Coraflon® fluoropolymer finish• Painted in a hi-gloss polyurethane finish• Clear satin anodized finish• Light, medium, or dark bronze, or black anodized finish• Clad with matte or hi-gloss plastic laminate finishes• Clad with Belbien® vinyl laminate finishes• Clad with wood veneers (unfinished)• Primed finish for field painting

2-1/2"(63.5 mm)Typ

Insert Factory Finished.Consult Factory for ColorSelection.1/2" (12.7 mm)Typical Soft 'V' Joint Typical ofSNAP-FORM® Column Covers

2-5/8"(66.7 mm)Typ

Pittcon specializes in all types of the highest quality architecturalpaint finishes, including fluoropolymer, acrylic polyurethane enamel,acrylic lacquer, etc.

Stainless Steel in 16ga -14ga thickness (1.6 mm-1.9 mm)• Pattern Metal finish (see Pattern Metal brochure for details)• #4 brushed finish• #8 polished finish• Rigid-Tex® Textured finishes• Prismatic® colored finishes

Muntz Brass in 14ga -12ga thickness (1.5 mm-2 mm)(Factory clearcoat available for an additional charge.)

• #4 brushed finish• #8 polished finish

Coraflon® is a registered trademark of PPG Industries.Rigid-Tex® is a registered trademark of Rigidized Metals Corp.Prismatic® is a registered trademark of B & M Finishers, Inc.Belbien® is a registered trademark of the C.I. Kasei Company, LTD of Japan.

Our state of the art finishing booth with down-draft air filtration system assures maximumdust and temperature control.

Series 1500-DetailsSeries 1500-DetailsSeries 1500-DetailsSeries 1500-DetailsSeries 1500-Details

SIDELOCKSIDELOCKSIDELOCKSIDELOCKSIDELOCKtmtmtmtmtm Reveal Joint Reveal Joint Reveal Joint Reveal Joint Reveal Joint SNAP-FORMSNAP-FORMSNAP-FORMSNAP-FORMSNAP-FORM®®®®® Soft "V" Joint Soft "V" Joint Soft "V" Joint Soft "V" Joint Soft "V" Joint

Other materials and thicknesses are available as options, at anadditional cost. Factory primed or mill finish available for imme-diate delivery. Finishes meet or exceed AAMA standards forscratches or blemishes.

Series 1500-InstallationSeries 1500-InstallationSeries 1500-InstallationSeries 1500-InstallationSeries 1500-Installation

Fabricated with Pride in

Riverdale, Maryland-U.S.A.88888

Installation DetailsInstallation DetailsInstallation DetailsInstallation DetailsInstallation DetailsNo ScaleNo ScaleNo ScaleNo ScaleNo Scale

Secure MountingBracket to FloorUsing ProperFasteners(Not Provided)

Aluminum PostNote:Post Height Should be 1"Less than Column Heightto Allow for Adjustment

Telescoping PostMounting Bracket

Use Plumb Bob orLevel to EnsurePosts are InstalledCorrectly

Wooden Post Installa-tion Template

The SERIES 1500 column cover system consists of the following parts:1) Two custom rolled column cover half sections2) Four post mounting brackets with mounting screws3) Two extruded aluminum posts (with reveal inserts if SIDE-LOCKTM)4) Mid-level post reinforcement brackets5) Self tapping flat head screws for bracket attachment6) Post installation template for aligning posts7) One set of drawings / instructions / suction cup per order

The following customer supplied items are also recommended:1) Plumb bob & carpenters level2) Ramset or lag type masonry fasteners for mounting brackets

Typical Installation Procedure1) Determine the position of the column cover around structural member.

Install one stud in place, using a level to ensure plumb-ness. Position theopposite stud in place using the supplied post installation template. Makesure that studs are securely fastened to the ceiling and floor utilizing properfasteners. Install any base reveals at this time fastening to both post andfloor.

2) Seat one side of first column half into the opening of the metal post. Usingthe suction cup, spring column half gently around outside of opposite postand seat in opening. Repeat this procedure for the other column half, takingcare not to unduly stretch halves.

3) If column cover is a SNAP-FORM® model, use a heavily padded 2x4 andrubber mallet to engage the two sides. Starting at the bottom of the columncover and working your way up, firmly strike the padded block with therubber hammer on both column halves along joint. This will positivelyengage the interlock assembly. If your column is a SIDE-LOCK model, insertthe vertical locking reveal between the two column halves and engage it inthe post. This is accomplished by using a heavily padded board (7/16" orless in width) to strike the insert with, starting at the bottom and working yourway upwards. Install any top reveals last, making sure that they are properlysupported to ceiling and post.

4) Remove the protective covering from the column cover halves and clean asper attached directions. Your column cover is now complete.

SAMPLE SPECIFICATIONSection 05-58-13 Architectural Metal Column CoversPart 1 - General1.01 Description of work

A. Furnish all material necessary for a complete installation ofthe SERIES 1500 column covers. Column covers to be self-aligning, positive interlock, without exposed fasteners orsupports.

1.02 SubmittalsA. Submit complete shop drawings detailing quantities, sizes,finish, configurations, and column attachment methods.B. Submit product literature, specifications, information, andinstallation instructions.

1.03 Quality AssuranceA. Manufacturer to have a minimum of ten years experiencein the manufacturing of column covers.B. Manufacturer to inspect all aspects of the product to ensurethat specifications have been met, and that they comply withapproved shop drawings.C. Manufacturer shall issue a one year limited warrantyensuring product against defects in workmanship and mate-rials.

Part 2 - Products2.01 Acceptable Manufacturers

Pittcon Industries Pittcon Industries6409 Rhode Island Ave. 3330 W. Flower StreetRiverdale, MD 20737 Phoenix, Arizona 85017

2.02 MaterialsA. Column covers shall be roll-formed from (Specified Material) with(Specified Finish) to match architects sample.B. All fasteners are to be concealed.C. All support structures to be supplied by column cover manufacturer.D. All column covers are to be shipped with protective material on allexposed surfaces.

2.03 FabricationA. Column covers shall be roll-formed to specific dimensions andtolerances, and accurately formed to radii shown on drawings.B. Column covers shall be fabricated in two vertically divided sectionsattached with a demountable interlock joint.C. Column covers shall be fabricated in single length heights of 16'where required, with the addition of stacking joints to allow for heightsabove 16'.

Part 3 - Execution3.01 Inspection & Installation

A. Contractor to inspect column covers upon receipt to ensure that nodamage has occurred during shipment.B. Column cover to be correctly oriented and installed in accordancewith manufacturer's shop drawings and installation instructions toensure proper installation.C. Column cover to be erected plumb and level.

3.02 Cleaning & ProtectionA. Contractor to remove protective material supplied by column covermanufacturer.B. Contractor to clean all visible surfaces after installation.C. Contractor to protect column covers from damage by other trades

c 2008 Pittcon Industries

Pittcon Industries Division Pittcon Architectural Metals, LLC6409 Rhode Island Avenue 3330 W. Flower StreetRiverdale, Maryland 20737 Phoenix, Arizona 85017(800) 637-7638 , (301) 927-1000 (800) 637-7638 , (602) 233-9100Fax: (301) 699-8690 Fax: (602) 233-9400