48
Series S Sanitary Sensors and Thermowells

Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Series S Sanitary Sensors and Thermowells

The Series S family of sensors and thermowells are specifically

designed to meet strict sanitary requirements and provide temperature

measurement confidence in your processes From 18 inch Mini Sensors

to Non-Intrusive designs the Series S offers SIP CIP HTST capable

performance and material traceability to meet the stringent quality

systems of the Pharmaceutical Biotech and Food Processing industries

Allow us to provide a quote Call us at 800-328-3871 or configure your own

quote through our Web Quote system

Herersquos how Go to wwwburnsengineeringcom

1 Search for the model (S01 S40 SWE SNR) using the search box (upper right)

2 Click on configure

3 Select the parameters for your model

4 Add to Quote Cart

5 Submit Cart for Quote

Itrsquos fast easy and wersquoll get back to you within a day

Since 1960 Burns Engineering has been an industry leader in the design and

manufacture of temperature sensors Accuracy reliability and consistency

are hallmarks of the Burns brand At Burns temperature is our language

We understand the subtleties of temperature measurement and how they can

impact your processes and ultimately your success We worry about the details

so you donrsquot have to When you select Burns yoursquore getting more than a sensor

yoursquore getting your own team of Temperature Measurement Experts

Temperature Measurement Expertsreg

Series S Sanitary Sensors and Thermowells

Product Index2

Series S Sanitary Sensors and Thermowells

Series S Overview and Specifications Pages 3 amp 4

Application and Product Selection Guide Pages 5 amp 6

S01- 18rdquo Direct Immersion Pages 7 amp 8The S01 is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches

S03- 14rdquo Direct Immersion Pages 7 amp 8The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S20- Fast Response 14rdquo x 18rdquo Pages 9 amp 10The S20 direct immersion is used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter

S40- Heavy Duty 12rdquo x 14rdquo Pages 9 amp 10The S40 direct immersion is generally used in applications with longer immersion lengths that require the maximum physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter

S55- Sensor with 316rdquo Integral Thermowell Pages 11 amp 12The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package

S60- amp S65- 18rdquo and 14rdquo Spring Loaded Pages 13 amp 14The S60 and S65 series sensors are designed to be used with thermowells They provide a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

SWE- Elbow Thermowells Pages 15 - 18Our sanitary elbows are designed to fit your application and provide minimal flow restriction

SWT- Standard Thermowells Pages 19 amp 20SWT sanitary thermowells are used in applications that require sensor removal during process operation

SNx- Non-Intrusive Pages 21 - 30The SNx family of products include the SNI the SNS with a shorter installation length and the SNR with a removable sensor for ease of calibration or replacement

SPA- amp SPS- Ingoldreg Port Pages 31 amp 32 For use in fermentation vessels or anywhere an Ingoldreg port is present

SFM- Flush Mount Pages 33 amp 34For use in vessels where a probe might interfere with the mixing blades or other rotating equipment

Options Pages 35 amp 36A variety of options are available to enhance your sensor selection including leadwires calibration strain relief tagging cable glands remote mount and documentation(certifications)

Transmitters Page 37 amp 38

Accessories Page 39

Connection Head Descriptions Page 40

Reference Tables- R vs T indegF and degC Pages 41 amp 42

Reference Tables- mV vs T in degF and degC Pages 43 amp 44

Terminology Guide Pages 45 amp 46

Temperature Measurement Expertsreg wwwburnsengineeringcom

Designed For Performance and Reliability3

Series S sensors are designed to meet strict sanitary requirements and provide top performance in a wide

variety of applications

The Burns design team through their participation in the ASME-BPE Standard Committee on BioProcess

Equipment (BPE) and the 3A Sanitary Standard organization understands the important design characteristics

necessary to ensure performance and cleanability for sanitary operation

NET Solutiontrade

The NET Solution design provides an assembly with No Exposed Threads that eliminates the cracks and

crevices where bacteria dirt or other unwanted material can hide Watch for the NET Solution reference

throughout the Series S

Documentation amp Material Traceability

Burns Engineering offers as standard the most common certifications required for sanitary applications For

all Series S sensors and thermowells that contain ldquowettedrdquo surfaces the heat numbers of all ldquowettedrdquo materials

are marked on the extension and a material traceability certificate is included A certificate of surface finish and

electropolish are automatically provided when applicable - no need to specify these certifications

All certificates are supplied in hard copy as standard practice Several electronic formats are also available

upon request

3A 74 Conformance

Detailed attention to the design material and fabrication

criteria set forth in the most current revision of 3A Sanitary

Standard number 74 Look for the 3A logo on approved

products

BPE Standard

The guidelines regarding Metallic Materials (MM) Material Joining

(MJ) Sanitary Design (SD) and other parts of the BPE Standard are

a core consideration within the Series S product design as a Process

Instrument (PI)

Custom documentation packages and NVLAP accredited

calibration can be supplied to meet all of your quality

and validation requirements Contact your local Burns

representative or Burns Customer Service for more

information on custom documentation packages

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Specifications4

Thermocouples

RTDSOperating Temperature Range

-50ordmC to 200ordmCElement Resistance

100 ohms at 0degC nominalTemperature Coefficient of Resistance (alpha)

000385 ΩΩdegC nominalAccuracy

Standard 010 of resistance at 0degCPrecision 005 of resistance at 0degC

Insulation Resistance 100 megohms minimum at 100 VDC at 25degC (Not applicable for grounded thermocouples)

InterchangeabilityFor 100 ohm elements the tolerance values at any temperature for these specifications are given by Tolerance degC = plusmn(013 + 000185 ItI) for accuracy code 05 Tolerance degC = plusmn(026 + 00037 ItI) for accuracy code 10 (ItI = absolute value of temperature in degC)

LeadwirePTFE insulated nickel-plated stranded copper 22 and 24 AWG typical

Sheath Material 316L stainless steel typical

100 TestedFor accuracy at 0degC and insulation resistance

WHITE

RED

RED

WHITE

RED

RED

WHITE

Color Codes ElementLeadwire Configuration

A - Three Wire B - Four Wire

BLACKWHITE

RED

RED GREEN

GREEN

C - Three Wire Dual

METAL GUIDE

2

1

GUIDE MARK

PIN 1 WHITEPIN 2 REDPIN 3 RED3

METAL GUIDE

1 3

2

GUIDE MARK

Quick Disconnect

Plug Receptacle

degC degF

-50 -58 plusmn23degC plusmn41degF plusmn45degC plusmn80degF0 32 plusmn13degC plusmn23degF plusmn26degC plusmn46degF

100 212 plusmn32degC plusmn57degF plusmn64degC plusmn115degF

200 392 plusmn50degC plusmn90degF plusmn100degC plusmn180degF

Temperature Interchangeability010005

The tables listed below are provided to the user for a ready reference of thermocouple designations as compared to the generic and trade names for the most common thermocouple materials The letter ldquoPrdquo in the designation indicates the positive (+) leg of the thermocouple while the letter ldquoNrdquo designates the negative (-) Color coding and other means of conductor identification are also provided Specification reference per ASTME230 E230M

plusmn005 accuracy is not currently available with all models See the Ordering Information Table for each model for applicability

applies to measurement in degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EP No Purple

Constantan EN No Red

Iron JP Yes White

Constantan JN No Red

Chromel KP No Yellow

Alumel KN Yes Red

Copper TP No Blue

Constantan TN No Red

KBrown w

Yellow Tracer

TBrown w Blue

Tracer

EBrown w

Purple Tracer

JBrown w

White Tracer

Thermocouple Grade Wire

reg

regreg

ANSI Thermocouple

TypeTemperature Range Special Limits

T -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

J 0degC to 200degC plusmn11degC

E -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

K 0degC to 200degC plusmn11degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EPX No Purple

Constantan ENX No Red

JPX Yes White

JNX No Red

Chromelreg KPX No Yellow

Alumelreg KNX Yes Red

Copper TPX No Blue

Constantan TNX No Red

KX Yellow

TX Blue

EX Purple

JX BlackIron Constantan

Extension Grade Wire

reg

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 2: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

The Series S family of sensors and thermowells are specifically

designed to meet strict sanitary requirements and provide temperature

measurement confidence in your processes From 18 inch Mini Sensors

to Non-Intrusive designs the Series S offers SIP CIP HTST capable

performance and material traceability to meet the stringent quality

systems of the Pharmaceutical Biotech and Food Processing industries

Allow us to provide a quote Call us at 800-328-3871 or configure your own

quote through our Web Quote system

Herersquos how Go to wwwburnsengineeringcom

1 Search for the model (S01 S40 SWE SNR) using the search box (upper right)

2 Click on configure

3 Select the parameters for your model

4 Add to Quote Cart

5 Submit Cart for Quote

Itrsquos fast easy and wersquoll get back to you within a day

Since 1960 Burns Engineering has been an industry leader in the design and

manufacture of temperature sensors Accuracy reliability and consistency

are hallmarks of the Burns brand At Burns temperature is our language

We understand the subtleties of temperature measurement and how they can

impact your processes and ultimately your success We worry about the details

so you donrsquot have to When you select Burns yoursquore getting more than a sensor

yoursquore getting your own team of Temperature Measurement Experts

Temperature Measurement Expertsreg

Series S Sanitary Sensors and Thermowells

Product Index2

Series S Sanitary Sensors and Thermowells

Series S Overview and Specifications Pages 3 amp 4

Application and Product Selection Guide Pages 5 amp 6

S01- 18rdquo Direct Immersion Pages 7 amp 8The S01 is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches

S03- 14rdquo Direct Immersion Pages 7 amp 8The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S20- Fast Response 14rdquo x 18rdquo Pages 9 amp 10The S20 direct immersion is used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter

S40- Heavy Duty 12rdquo x 14rdquo Pages 9 amp 10The S40 direct immersion is generally used in applications with longer immersion lengths that require the maximum physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter

S55- Sensor with 316rdquo Integral Thermowell Pages 11 amp 12The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package

S60- amp S65- 18rdquo and 14rdquo Spring Loaded Pages 13 amp 14The S60 and S65 series sensors are designed to be used with thermowells They provide a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

SWE- Elbow Thermowells Pages 15 - 18Our sanitary elbows are designed to fit your application and provide minimal flow restriction

SWT- Standard Thermowells Pages 19 amp 20SWT sanitary thermowells are used in applications that require sensor removal during process operation

SNx- Non-Intrusive Pages 21 - 30The SNx family of products include the SNI the SNS with a shorter installation length and the SNR with a removable sensor for ease of calibration or replacement

SPA- amp SPS- Ingoldreg Port Pages 31 amp 32 For use in fermentation vessels or anywhere an Ingoldreg port is present

SFM- Flush Mount Pages 33 amp 34For use in vessels where a probe might interfere with the mixing blades or other rotating equipment

Options Pages 35 amp 36A variety of options are available to enhance your sensor selection including leadwires calibration strain relief tagging cable glands remote mount and documentation(certifications)

Transmitters Page 37 amp 38

Accessories Page 39

Connection Head Descriptions Page 40

Reference Tables- R vs T indegF and degC Pages 41 amp 42

Reference Tables- mV vs T in degF and degC Pages 43 amp 44

Terminology Guide Pages 45 amp 46

Temperature Measurement Expertsreg wwwburnsengineeringcom

Designed For Performance and Reliability3

Series S sensors are designed to meet strict sanitary requirements and provide top performance in a wide

variety of applications

The Burns design team through their participation in the ASME-BPE Standard Committee on BioProcess

Equipment (BPE) and the 3A Sanitary Standard organization understands the important design characteristics

necessary to ensure performance and cleanability for sanitary operation

NET Solutiontrade

The NET Solution design provides an assembly with No Exposed Threads that eliminates the cracks and

crevices where bacteria dirt or other unwanted material can hide Watch for the NET Solution reference

throughout the Series S

Documentation amp Material Traceability

Burns Engineering offers as standard the most common certifications required for sanitary applications For

all Series S sensors and thermowells that contain ldquowettedrdquo surfaces the heat numbers of all ldquowettedrdquo materials

are marked on the extension and a material traceability certificate is included A certificate of surface finish and

electropolish are automatically provided when applicable - no need to specify these certifications

All certificates are supplied in hard copy as standard practice Several electronic formats are also available

upon request

3A 74 Conformance

Detailed attention to the design material and fabrication

criteria set forth in the most current revision of 3A Sanitary

Standard number 74 Look for the 3A logo on approved

products

BPE Standard

The guidelines regarding Metallic Materials (MM) Material Joining

(MJ) Sanitary Design (SD) and other parts of the BPE Standard are

a core consideration within the Series S product design as a Process

Instrument (PI)

Custom documentation packages and NVLAP accredited

calibration can be supplied to meet all of your quality

and validation requirements Contact your local Burns

representative or Burns Customer Service for more

information on custom documentation packages

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Specifications4

Thermocouples

RTDSOperating Temperature Range

-50ordmC to 200ordmCElement Resistance

100 ohms at 0degC nominalTemperature Coefficient of Resistance (alpha)

000385 ΩΩdegC nominalAccuracy

Standard 010 of resistance at 0degCPrecision 005 of resistance at 0degC

Insulation Resistance 100 megohms minimum at 100 VDC at 25degC (Not applicable for grounded thermocouples)

InterchangeabilityFor 100 ohm elements the tolerance values at any temperature for these specifications are given by Tolerance degC = plusmn(013 + 000185 ItI) for accuracy code 05 Tolerance degC = plusmn(026 + 00037 ItI) for accuracy code 10 (ItI = absolute value of temperature in degC)

LeadwirePTFE insulated nickel-plated stranded copper 22 and 24 AWG typical

Sheath Material 316L stainless steel typical

100 TestedFor accuracy at 0degC and insulation resistance

WHITE

RED

RED

WHITE

RED

RED

WHITE

Color Codes ElementLeadwire Configuration

A - Three Wire B - Four Wire

BLACKWHITE

RED

RED GREEN

GREEN

C - Three Wire Dual

METAL GUIDE

2

1

GUIDE MARK

PIN 1 WHITEPIN 2 REDPIN 3 RED3

METAL GUIDE

1 3

2

GUIDE MARK

Quick Disconnect

Plug Receptacle

degC degF

-50 -58 plusmn23degC plusmn41degF plusmn45degC plusmn80degF0 32 plusmn13degC plusmn23degF plusmn26degC plusmn46degF

100 212 plusmn32degC plusmn57degF plusmn64degC plusmn115degF

200 392 plusmn50degC plusmn90degF plusmn100degC plusmn180degF

Temperature Interchangeability010005

The tables listed below are provided to the user for a ready reference of thermocouple designations as compared to the generic and trade names for the most common thermocouple materials The letter ldquoPrdquo in the designation indicates the positive (+) leg of the thermocouple while the letter ldquoNrdquo designates the negative (-) Color coding and other means of conductor identification are also provided Specification reference per ASTME230 E230M

plusmn005 accuracy is not currently available with all models See the Ordering Information Table for each model for applicability

applies to measurement in degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EP No Purple

Constantan EN No Red

Iron JP Yes White

Constantan JN No Red

Chromel KP No Yellow

Alumel KN Yes Red

Copper TP No Blue

Constantan TN No Red

KBrown w

Yellow Tracer

TBrown w Blue

Tracer

EBrown w

Purple Tracer

JBrown w

White Tracer

Thermocouple Grade Wire

reg

regreg

ANSI Thermocouple

TypeTemperature Range Special Limits

T -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

J 0degC to 200degC plusmn11degC

E -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

K 0degC to 200degC plusmn11degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EPX No Purple

Constantan ENX No Red

JPX Yes White

JNX No Red

Chromelreg KPX No Yellow

Alumelreg KNX Yes Red

Copper TPX No Blue

Constantan TNX No Red

KX Yellow

TX Blue

EX Purple

JX BlackIron Constantan

Extension Grade Wire

reg

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 3: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Product Index2

Series S Sanitary Sensors and Thermowells

Series S Overview and Specifications Pages 3 amp 4

Application and Product Selection Guide Pages 5 amp 6

S01- 18rdquo Direct Immersion Pages 7 amp 8The S01 is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches

S03- 14rdquo Direct Immersion Pages 7 amp 8The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S20- Fast Response 14rdquo x 18rdquo Pages 9 amp 10The S20 direct immersion is used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter

S40- Heavy Duty 12rdquo x 14rdquo Pages 9 amp 10The S40 direct immersion is generally used in applications with longer immersion lengths that require the maximum physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter

S55- Sensor with 316rdquo Integral Thermowell Pages 11 amp 12The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package

S60- amp S65- 18rdquo and 14rdquo Spring Loaded Pages 13 amp 14The S60 and S65 series sensors are designed to be used with thermowells They provide a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

SWE- Elbow Thermowells Pages 15 - 18Our sanitary elbows are designed to fit your application and provide minimal flow restriction

SWT- Standard Thermowells Pages 19 amp 20SWT sanitary thermowells are used in applications that require sensor removal during process operation

SNx- Non-Intrusive Pages 21 - 30The SNx family of products include the SNI the SNS with a shorter installation length and the SNR with a removable sensor for ease of calibration or replacement

SPA- amp SPS- Ingoldreg Port Pages 31 amp 32 For use in fermentation vessels or anywhere an Ingoldreg port is present

SFM- Flush Mount Pages 33 amp 34For use in vessels where a probe might interfere with the mixing blades or other rotating equipment

Options Pages 35 amp 36A variety of options are available to enhance your sensor selection including leadwires calibration strain relief tagging cable glands remote mount and documentation(certifications)

Transmitters Page 37 amp 38

Accessories Page 39

Connection Head Descriptions Page 40

Reference Tables- R vs T indegF and degC Pages 41 amp 42

Reference Tables- mV vs T in degF and degC Pages 43 amp 44

Terminology Guide Pages 45 amp 46

Temperature Measurement Expertsreg wwwburnsengineeringcom

Designed For Performance and Reliability3

Series S sensors are designed to meet strict sanitary requirements and provide top performance in a wide

variety of applications

The Burns design team through their participation in the ASME-BPE Standard Committee on BioProcess

Equipment (BPE) and the 3A Sanitary Standard organization understands the important design characteristics

necessary to ensure performance and cleanability for sanitary operation

NET Solutiontrade

The NET Solution design provides an assembly with No Exposed Threads that eliminates the cracks and

crevices where bacteria dirt or other unwanted material can hide Watch for the NET Solution reference

throughout the Series S

Documentation amp Material Traceability

Burns Engineering offers as standard the most common certifications required for sanitary applications For

all Series S sensors and thermowells that contain ldquowettedrdquo surfaces the heat numbers of all ldquowettedrdquo materials

are marked on the extension and a material traceability certificate is included A certificate of surface finish and

electropolish are automatically provided when applicable - no need to specify these certifications

All certificates are supplied in hard copy as standard practice Several electronic formats are also available

upon request

3A 74 Conformance

Detailed attention to the design material and fabrication

criteria set forth in the most current revision of 3A Sanitary

Standard number 74 Look for the 3A logo on approved

products

BPE Standard

The guidelines regarding Metallic Materials (MM) Material Joining

(MJ) Sanitary Design (SD) and other parts of the BPE Standard are

a core consideration within the Series S product design as a Process

Instrument (PI)

Custom documentation packages and NVLAP accredited

calibration can be supplied to meet all of your quality

and validation requirements Contact your local Burns

representative or Burns Customer Service for more

information on custom documentation packages

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Specifications4

Thermocouples

RTDSOperating Temperature Range

-50ordmC to 200ordmCElement Resistance

100 ohms at 0degC nominalTemperature Coefficient of Resistance (alpha)

000385 ΩΩdegC nominalAccuracy

Standard 010 of resistance at 0degCPrecision 005 of resistance at 0degC

Insulation Resistance 100 megohms minimum at 100 VDC at 25degC (Not applicable for grounded thermocouples)

InterchangeabilityFor 100 ohm elements the tolerance values at any temperature for these specifications are given by Tolerance degC = plusmn(013 + 000185 ItI) for accuracy code 05 Tolerance degC = plusmn(026 + 00037 ItI) for accuracy code 10 (ItI = absolute value of temperature in degC)

LeadwirePTFE insulated nickel-plated stranded copper 22 and 24 AWG typical

Sheath Material 316L stainless steel typical

100 TestedFor accuracy at 0degC and insulation resistance

WHITE

RED

RED

WHITE

RED

RED

WHITE

Color Codes ElementLeadwire Configuration

A - Three Wire B - Four Wire

BLACKWHITE

RED

RED GREEN

GREEN

C - Three Wire Dual

METAL GUIDE

2

1

GUIDE MARK

PIN 1 WHITEPIN 2 REDPIN 3 RED3

METAL GUIDE

1 3

2

GUIDE MARK

Quick Disconnect

Plug Receptacle

degC degF

-50 -58 plusmn23degC plusmn41degF plusmn45degC plusmn80degF0 32 plusmn13degC plusmn23degF plusmn26degC plusmn46degF

100 212 plusmn32degC plusmn57degF plusmn64degC plusmn115degF

200 392 plusmn50degC plusmn90degF plusmn100degC plusmn180degF

Temperature Interchangeability010005

The tables listed below are provided to the user for a ready reference of thermocouple designations as compared to the generic and trade names for the most common thermocouple materials The letter ldquoPrdquo in the designation indicates the positive (+) leg of the thermocouple while the letter ldquoNrdquo designates the negative (-) Color coding and other means of conductor identification are also provided Specification reference per ASTME230 E230M

plusmn005 accuracy is not currently available with all models See the Ordering Information Table for each model for applicability

applies to measurement in degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EP No Purple

Constantan EN No Red

Iron JP Yes White

Constantan JN No Red

Chromel KP No Yellow

Alumel KN Yes Red

Copper TP No Blue

Constantan TN No Red

KBrown w

Yellow Tracer

TBrown w Blue

Tracer

EBrown w

Purple Tracer

JBrown w

White Tracer

Thermocouple Grade Wire

reg

regreg

ANSI Thermocouple

TypeTemperature Range Special Limits

T -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

J 0degC to 200degC plusmn11degC

E -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

K 0degC to 200degC plusmn11degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EPX No Purple

Constantan ENX No Red

JPX Yes White

JNX No Red

Chromelreg KPX No Yellow

Alumelreg KNX Yes Red

Copper TPX No Blue

Constantan TNX No Red

KX Yellow

TX Blue

EX Purple

JX BlackIron Constantan

Extension Grade Wire

reg

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 4: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Designed For Performance and Reliability3

Series S sensors are designed to meet strict sanitary requirements and provide top performance in a wide

variety of applications

The Burns design team through their participation in the ASME-BPE Standard Committee on BioProcess

Equipment (BPE) and the 3A Sanitary Standard organization understands the important design characteristics

necessary to ensure performance and cleanability for sanitary operation

NET Solutiontrade

The NET Solution design provides an assembly with No Exposed Threads that eliminates the cracks and

crevices where bacteria dirt or other unwanted material can hide Watch for the NET Solution reference

throughout the Series S

Documentation amp Material Traceability

Burns Engineering offers as standard the most common certifications required for sanitary applications For

all Series S sensors and thermowells that contain ldquowettedrdquo surfaces the heat numbers of all ldquowettedrdquo materials

are marked on the extension and a material traceability certificate is included A certificate of surface finish and

electropolish are automatically provided when applicable - no need to specify these certifications

All certificates are supplied in hard copy as standard practice Several electronic formats are also available

upon request

3A 74 Conformance

Detailed attention to the design material and fabrication

criteria set forth in the most current revision of 3A Sanitary

Standard number 74 Look for the 3A logo on approved

products

BPE Standard

The guidelines regarding Metallic Materials (MM) Material Joining

(MJ) Sanitary Design (SD) and other parts of the BPE Standard are

a core consideration within the Series S product design as a Process

Instrument (PI)

Custom documentation packages and NVLAP accredited

calibration can be supplied to meet all of your quality

and validation requirements Contact your local Burns

representative or Burns Customer Service for more

information on custom documentation packages

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Specifications4

Thermocouples

RTDSOperating Temperature Range

-50ordmC to 200ordmCElement Resistance

100 ohms at 0degC nominalTemperature Coefficient of Resistance (alpha)

000385 ΩΩdegC nominalAccuracy

Standard 010 of resistance at 0degCPrecision 005 of resistance at 0degC

Insulation Resistance 100 megohms minimum at 100 VDC at 25degC (Not applicable for grounded thermocouples)

InterchangeabilityFor 100 ohm elements the tolerance values at any temperature for these specifications are given by Tolerance degC = plusmn(013 + 000185 ItI) for accuracy code 05 Tolerance degC = plusmn(026 + 00037 ItI) for accuracy code 10 (ItI = absolute value of temperature in degC)

LeadwirePTFE insulated nickel-plated stranded copper 22 and 24 AWG typical

Sheath Material 316L stainless steel typical

100 TestedFor accuracy at 0degC and insulation resistance

WHITE

RED

RED

WHITE

RED

RED

WHITE

Color Codes ElementLeadwire Configuration

A - Three Wire B - Four Wire

BLACKWHITE

RED

RED GREEN

GREEN

C - Three Wire Dual

METAL GUIDE

2

1

GUIDE MARK

PIN 1 WHITEPIN 2 REDPIN 3 RED3

METAL GUIDE

1 3

2

GUIDE MARK

Quick Disconnect

Plug Receptacle

degC degF

-50 -58 plusmn23degC plusmn41degF plusmn45degC plusmn80degF0 32 plusmn13degC plusmn23degF plusmn26degC plusmn46degF

100 212 plusmn32degC plusmn57degF plusmn64degC plusmn115degF

200 392 plusmn50degC plusmn90degF plusmn100degC plusmn180degF

Temperature Interchangeability010005

The tables listed below are provided to the user for a ready reference of thermocouple designations as compared to the generic and trade names for the most common thermocouple materials The letter ldquoPrdquo in the designation indicates the positive (+) leg of the thermocouple while the letter ldquoNrdquo designates the negative (-) Color coding and other means of conductor identification are also provided Specification reference per ASTME230 E230M

plusmn005 accuracy is not currently available with all models See the Ordering Information Table for each model for applicability

applies to measurement in degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EP No Purple

Constantan EN No Red

Iron JP Yes White

Constantan JN No Red

Chromel KP No Yellow

Alumel KN Yes Red

Copper TP No Blue

Constantan TN No Red

KBrown w

Yellow Tracer

TBrown w Blue

Tracer

EBrown w

Purple Tracer

JBrown w

White Tracer

Thermocouple Grade Wire

reg

regreg

ANSI Thermocouple

TypeTemperature Range Special Limits

T -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

J 0degC to 200degC plusmn11degC

E -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

K 0degC to 200degC plusmn11degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EPX No Purple

Constantan ENX No Red

JPX Yes White

JNX No Red

Chromelreg KPX No Yellow

Alumelreg KNX Yes Red

Copper TPX No Blue

Constantan TNX No Red

KX Yellow

TX Blue

EX Purple

JX BlackIron Constantan

Extension Grade Wire

reg

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 5: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Specifications4

Thermocouples

RTDSOperating Temperature Range

-50ordmC to 200ordmCElement Resistance

100 ohms at 0degC nominalTemperature Coefficient of Resistance (alpha)

000385 ΩΩdegC nominalAccuracy

Standard 010 of resistance at 0degCPrecision 005 of resistance at 0degC

Insulation Resistance 100 megohms minimum at 100 VDC at 25degC (Not applicable for grounded thermocouples)

InterchangeabilityFor 100 ohm elements the tolerance values at any temperature for these specifications are given by Tolerance degC = plusmn(013 + 000185 ItI) for accuracy code 05 Tolerance degC = plusmn(026 + 00037 ItI) for accuracy code 10 (ItI = absolute value of temperature in degC)

LeadwirePTFE insulated nickel-plated stranded copper 22 and 24 AWG typical

Sheath Material 316L stainless steel typical

100 TestedFor accuracy at 0degC and insulation resistance

WHITE

RED

RED

WHITE

RED

RED

WHITE

Color Codes ElementLeadwire Configuration

A - Three Wire B - Four Wire

BLACKWHITE

RED

RED GREEN

GREEN

C - Three Wire Dual

METAL GUIDE

2

1

GUIDE MARK

PIN 1 WHITEPIN 2 REDPIN 3 RED3

METAL GUIDE

1 3

2

GUIDE MARK

Quick Disconnect

Plug Receptacle

degC degF

-50 -58 plusmn23degC plusmn41degF plusmn45degC plusmn80degF0 32 plusmn13degC plusmn23degF plusmn26degC plusmn46degF

100 212 plusmn32degC plusmn57degF plusmn64degC plusmn115degF

200 392 plusmn50degC plusmn90degF plusmn100degC plusmn180degF

Temperature Interchangeability010005

The tables listed below are provided to the user for a ready reference of thermocouple designations as compared to the generic and trade names for the most common thermocouple materials The letter ldquoPrdquo in the designation indicates the positive (+) leg of the thermocouple while the letter ldquoNrdquo designates the negative (-) Color coding and other means of conductor identification are also provided Specification reference per ASTME230 E230M

plusmn005 accuracy is not currently available with all models See the Ordering Information Table for each model for applicability

applies to measurement in degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EP No Purple

Constantan EN No Red

Iron JP Yes White

Constantan JN No Red

Chromel KP No Yellow

Alumel KN Yes Red

Copper TP No Blue

Constantan TN No Red

KBrown w

Yellow Tracer

TBrown w Blue

Tracer

EBrown w

Purple Tracer

JBrown w

White Tracer

Thermocouple Grade Wire

reg

regreg

ANSI Thermocouple

TypeTemperature Range Special Limits

T -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

J 0degC to 200degC plusmn11degC

E -50degC to 125degC plusmn05degC125degC to 200degC plusmn04

K 0degC to 200degC plusmn11degC

ANSI Type

Grade or Generic Trade Names

Single Conductors

MagneticConductor Color Code

Overall Color Code

Chromel EPX No Purple

Constantan ENX No Red

JPX Yes White

JNX No Red

Chromelreg KPX No Yellow

Alumelreg KNX Yes Red

Copper TPX No Blue

Constantan TNX No Red

KX Yellow

TX Blue

EX Purple

JX BlackIron Constantan

Extension Grade Wire

reg

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 6: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

5

ProcessSheath Length

Sanitary Sensor

Outlet Size

Line Size

StandardlsquoCrsquo Length

Gasket Clearance

LineImmersion

Clearance

Wall Thickness

When using the Series S models with a standard or short immersion tee it is important to specify the correct process sheath length for the best performance The sheath length must be immersed in the process far enough to eliminate measurement errors due to stem conduction (minimum process sheath length) The sheath length must also maintain clearance between the sheath tip and the inside wall of the process line (maximum process sheath length) Use the tables on page 6 to determine the minimum and maximum recommended process sheath lengths for the tee used in the application Then use the table to choose a model appropriate for the application and its corresponding standard process sheath length for that length range lengths

Application and Product Selection GuideImmersion Sensors in Standard or Short Outlet Tees

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 7: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Using the table for Short Outlet Tee the following information is determined

Standard lsquoCrsquo dimension = 138rdquo

Minimum recommended process sheath length = 098rdquo

Maximum recommended process sheath length = 203rdquo

Applicable Models

Series S01 with a standard process sheath length of 110rdquo

Series S55 with a standard process sheath length of 125rdquo

Series S60 with a standard process sheath length of 125rdquo

Application and Product Selection Guide6

Definitions

Clearance = 006 Inches

Wall Thickness = 0065 Inches

Gasket Clearance = 003 Inches

Minimum Line Immersion = 025 Inches

Minimum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance - (Line Size2) + Minimum Line Immersion + Wall Thickness

Maximum Process Sheath Length = Standard lsquoCrsquo Length + Gasket Clearance + (Line Size2) - Clearance - Wall Thickness

Example For a 15rdquo x 15rdquo short outlet tee what Series S models can be used and what standard process sheath lengths are available

050 075 100 150 200 250 300 400 Min Max S01 S03 S20 S40 S55 S60 S65050 radic 100 110 115 110 - - - - - -075 radic 100 097 128 110 - - - -075 radic 113 110 141 - - -

125-

10 radic radic radic 113 098 153 - - -125

-15 radic radic radic radic 138 098 203 - - - -20 radic radic radic radic radic 163 098 253 250 - - -25 radic radic 188 098 303 250 - 300 -30 radic radic radic 213 098 353 250 350 300 -40 radic radic radic 263 098 453 350 300 40040 radic 275 110 465 350 300 400

Process Sheath Length

Recommended StandardStd C

Short Outlet Tee

Outlet SizeLine Size

250250

110110110

125125250250250400400

125125125125250250250400400

250250250400400

radic

ImmersionLength

SWT

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

50 75 10 15 20 25 30 40 Min Max S01 S03 S20 S40 S55 S60 S6550 radic 238 248 253 250 - - -75 radic 250 247 278 250 - - -10 radic 263 248 303 300 - 300 -15 radic 288 248 353 350 300 -20 313 248 403 350 300 40020

radic 363 273 478 40025

radic 388 273 528 400

25

radic 475 310 665

Standard Tee Process Sheath Length

Recommended StandardStd C

Line Size

Outlet Size

S60 and S65 models must be used in conjunction with a SWT thermowell Length stated is the thermowell Immersion length and not the C Compression Length

300300

300

300

-

350

350

350

300

300

400

250250250250400

400

400

400

250250250250400

400

400

400

250250250250400

400

400

400

30304040 -

radicradicradic 438 273 628 350 400 400 400 400300 300

radic 363 248 503 400300 350 300 400 400 400radic

radic 248 453 400300 350 300 400 400 400338radic 338 273 428 350 300 400300 400 400 400

radicradicradicradicradicradicradic

radicradicradic

SWT

ImmersionLength

Immersion Sensors in Standard or Short Outlet Tees

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 8: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors7

(20) ProcessSheath Length

Shown with 38rdquo UNF (N3)Sensor to Head Connection

(20)

(15)

Cable Length (120 std) ProcessSheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

Leads (60 std)

Process Connection

Process Connection

S01-18rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Process Sheath Length(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Process Connection

S03-14rdquo Direct Immersion Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NB) Quick Disconnect Full Assembly

Process Connection

rsquoNBrsquo and lsquoNCrsquo cable options are currently available with three wire single element sensors only

The 18rdquo diameter direct immersion (S01) is generally used in process lines less than 1 inch in diameter andor when the process has physical constraints that limit the immersion to less than 35 inches This sensor is available with cable or various thread sizes for connection heads

All dimensions in inches

All dimensions in inches

S01 Application

15 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature

in water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the

full temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

S01 Specifications

The S03 direct immersion is generally used in process lines greater than 1 inch in diameter and for immersion lengths between 35 and 240 inches

S03 Application S03 Specifications

60 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 9: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S01 amp S03 Direct Immersion Sensors8

NOTE 1 plusmn005 accuracy is not currently available with the S01 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf NOTE 3 Currently available with three wire single only

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance01- 18 Direct Immersion (NOTE 1) 10 85 +- 005rdquo03- 14 Direct Immersion 35 400 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S01 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0110 11 inches0250 25 inches0300 30 inches0350 35 inches0400 40 inches0500 50 inches0550 55 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head SensorHead Connection

-1C(NOTE 2)

12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 3) No Head Sensor with Quick Disconnect only no cable (NOTE 3)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

SOptions Transmitter

See pages 35 - 39Basic Order Codes

(Leave blank if not required)

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 10: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors9

The S20 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 14 inch sheath diameter and the time response of a 18 inch sheath diameter Use S20 in applications with immersions lengths between 35 and 240 inches

S20 Application S20 Specifications

The S40 direct immersion is generally used in applications with longer immersion lengths that require the physical durability associated with a 12 inch sheath diameter and the time response associated with a 14 inch sheath diameter Use S40 in applications with the longest immersion lengths (greater than 120 inches) and in high viscosity processes

S40 Application S40 Specifications

S20-Fast Response 14rdquo x 18ldquo sheath Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (6 std)

(10)

Process Connection

Process Sheath Length

(10)Process Connection

(20)

(15 inches)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

S40-Heavy Duty 12rdquo x 14ldquo sheath Available with cable (120rdquo standard) 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

(20)

(15)

Cable Length (120 std) Process Sheath Length

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(15)

Process Connection

Process Sheath Length

(15)

Process Connection

(225)

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

004

25 seconds

35 seconds

004

Precision (005) ndash 001

Standard (010) ndash 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision (005) ndash 004

Standard (010) ndash 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 11: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S20 amp S40 Direct Immersion Sensors10

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance20- Fast Response 30 240 +- 025rdquo40- Heavy Duty 40 480 +- 025rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0300 30 inches0400 40 inches0550 55 inches0750 75 inches0800 80 inches0950 95 inches1025 1025 inches1200 120 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P 12 NPT-9PN 12 NPSM-14S 12 NPT-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM-N3 38 UNF-NA na

Process TypeT Hygienic Ferrule (Tri-clamp style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-NB na-NC na

-19A-19AN-20P-20PN

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET SolutionNo Connection Head No Bushing NET SolutionNo Connection Head Cable Design 120 Nylon Spring StandardNo Head Sensor with Quick Disconnect and Mating 120rdquo cable (NOTE 2) No Head Sensor with Quick Disconnect only no cable (NOTE 2)

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-HeadspdfNOTE 2 Currently available with three wire single only

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 12: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

S55 Sensor with Integral Thermowell11

S55-Integral 316ldquo Well Available with 12rdquo NPT and 12rdquo NPSM head connection

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Process Sheath Length(225)Leads (60 std)

Process Connection

Process Connection

Shown with12rdquo NPT (N1)Sensor to Head Connection

(OAL = lsquoUrsquo Length + 2375rdquo)

lsquoUrsquo Length

Assembly InformationThe spring is retained by the hex fitting threaded onto the sensor extension and into the headWhen you pull slightly on the leads you will experience the spring actionTo remove the sensor thread the hex fitting off the sensor

General InformationThis is a spring loaded sensor with an integral thermowell The complete assembly and replacement sensor is ordered based on the lsquoUrsquo length

The S55 is a hybrid between a direct immersion sensor and a complete spring loaded thermowell assembly This configuration offers the convenience of a removable spring loaded sensing element and the functionality of a compact package Use the S55 in applications that require removal of the sensing element while the process is in operation

S55 Application S55 Specifications

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 008

Standard 010

15 seconds-sensor only

60 seconds typical in thermowell

Specifications

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 13: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S55 Sensor with Integral Thermowell12

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length Tolerance55- 316rdquo Sensor with Integral Thermowell 125 85 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C

Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches0700 70 inches0825 825 inches

Specify Process Sheath Length in InchesConnection Head (NOTE 1) SensorHead Connection

-1C 12 NPT-1EN 12 NPSM-2A 12 NPT-2E 12 NPT

-2EN 12 NPSM-5A 12 NPT-5E 12 NPT

-5EN 12 NPSM-9P 12 NPT

-9PN 12 NPSM-14S 12 NPT

-14SN 12 NPSM-16AN 38 UNF

-N1 12 NPT-N2 12 NPSM

Process TypeT Hygienic Ferrule (Tri-clamp Style)

Process Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

Wetted Surface Material03 316 Stainless Steel06 316L Stainless Steel

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

-19A-19AN-20P

-20PN

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Cast Iron Black EnamelCast Iron White Epoxy Coated NET SolutionAluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionPolypropylene WhitePolypropylene White NET SolutionStainless Steel Stainless Steel NET SolutionMiniature Aluminum NET Solution

No Connection Head BushingNo Connection Head Bushing NET Solution

Aluminum with LED IndicatorAluminum with LED Indicator NET SolutionPlastic with LED IndicatorPlastic with LED Indicator NET Solution

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 14: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors13

S60-Spring Loaded 18rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(225) lsquoCrsquo CompressedSheath Length

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Leads (60 std)

Extension Connection

316L Stainless Steel

S65-Spring Loaded 14rdquo Available with 12rdquo NPT and 12rdquo NPSM head connection

(30) lsquoCrsquo CompressedSheath Length

Extension Connection

316L Stainless Steel

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

(225) lsquoCrsquo CompressedSheath Length

Leads (60 std)

Shown with 12rdquo NPSM (N2)Sensor to Head Connection

Extension Connection

316L Stainless Steel

The S60 spring loaded sensor is designed to be used with the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

S60 Application

S65 Application

S60 Specifications

S65 SpecificationsThe S65 spring loaded sensor is designed to be used with the SWE sanitary elbow thermowell or the SWT standard sanitary thermowell The hygienic ferrule extension connection provides a quick and easy way to remove the sensor for calibration and process verification while eliminating the NPT threads normally used with a thermowell

15 seconds-sensor only

004

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Standard 010

Standard 008

40 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 15: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

S60 amp S65 Spring Loaded Sensors14

Sensor Style Min C Sheath Length Max C Sheath Length C Sheath Length Tolerance60- 18 Spring Loaded (NOTE 1) 125 85 +- 0125rdquo (non compressed length)

65- 14 Spring Loaded 20 600 +- 0125rdquo (non compressed length)

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C (not currently available with the S60 model)Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

C Compressed Sheath Length (Note sensor type minimum amp maximum values above)0125 125 inches0250 25 inches0400 40 inches0450 45 inches0550 55 inches0600 60 inches0825 825 inches

Specify Process Immersion Length in InchesConnection head (NOTE 2) SensorHead Connection

Extension ConnectionTypeT Hygienic Ferrule (Tri-clamp style)

Extension Connection Size (Used with tube sizes)05 12 12 3415 1 12 1 1 12 20 2 225 2 12 2 1230 3 340 4 4

-2A 12 NPT-2E 12 NPT-2EN 12 NPSM-5A 12 NPT-5E 12 NPT-5EN 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM

-N1 No Connection Head Bushing 12 NPT-N2 No Connection Head Bushing NET Solution 12 NPSM-N3 No Connection Head No Bushing NET Solution 38 UNF-NA No Connection Head Cable Design 120 Nylon Spring Standard na

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Aluminum GrayAluminum Epoxy CoatedAluminum Epoxy Coated NET SolutionAluminumAluminum Epoxy CoatedAluminum Epoxy Coated NET Solution

Ordering Information

NOTE 1 plusmn005 accuracy is not currently available with the S60 modelNOTE 2 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 16: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

15

Sanitary Well Elbow (SWE)1rdquo to 6rdquo Line Size (Straight Body) Well Specifications

Hygienic Ferrule Connection

Slope Typical

For Sanitary Hygienic Ferrule Connections See Below

ElbowSize

ElbowSize

Hygienic Ferrule12rdquo or 1 12rdquo

Optional Hygienic Ferrule Process Connection

12rdquo NPT

Optional Threaded Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitations

The SWE Straight Body design offers a range of sizes from 1 to 6 inches to support a wide range of processes This design can be configured with hygienic ferrule or weld-end process connections and either a threaded or a hygienic ferrule sensor connection The larger sizes are ideal for higher viscosity materials and ensure proper immersion for the most accurate temperature measurement All SWE products include certification of wetted surface materials and surface finish

The Straight Body design SWE can be installed in any orientation providing the line slope is sufficient to ensure gravity drainability

1rdquo to 6rdquo Style Elbow Thermowell

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 17: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

16

Sanitary Elbow (SWE)1rdquo to 6rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-100 1 Elbow-150 1 12 Elbow-200 2 Elbow-250 2 12 Elbow-300 3 Elbow-400 4 Elbow-600 6 Elbow

Style

S Straight Available with -100 (1 inch) or larger Elbow Size

Process Connection

A Hygienic Ferrule both inlet and outletB Weld ends both inlet and outletC Hygienic Ferrule inlet connection weld ends outlet connectionD Weld ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore DiameterOD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

354060

5625

22530

3375

Wall ThicknesslsquoX3rsquo Dimension Nominal

0065006500650065006500830109

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

For All Process Connections (A B C D)

bore depth + 15bore depth + 355625rdquo

11851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

Tri-clover Style Inlet Process Connection (A amp C)

12 Elbow

34Elbow

1 Elbow

1 12 Elbow

2 Elbow

2 12 Elbow

3 Elbow

4 Elbow

6 Elbow 575

0935

bore depth + 15bore depth + 355625rdquo

106311851435168519352185275

bore depth - 025bore depth + 05bore depth + 0875bore depth + 10

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 18: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

213

0deg OrientationCode ldquoE0rdquo

90deg OrientationCode ldquoE90rdquo

180deg OrientationCode ldquoE180rdquo

270deg OrientationCode ldquoE270rdquo

ConcentricCode ldquoCrdquo

225 225225 238

Sanitary Well Elbow (SWE)frac12rdquo and frac34rdquo Line Size (Reduced Body) Well Specification

For Hygienic Ferrule ProcessConnections See Below

NOTE 1 NOTE 2

ElbowSize

ElbowSize

NOTE Elbow Shown As Eccentric With 0deg Orientation For Other Configurations See Below

12rdquo NPT

Code ldquoE0rdquo

frac12rdquo and frac34rdquo Line Size Elbow Thermowell

InletOutlet Orientation

12rdquo Hygienic Ferrule

Optional Hygienic Ferrule Process Connection

OptionalHygienic Ferrule

Connection12rdquo or 1 12rdquo

Optional Hygienic Ferrule Sensor Connection

NOTE 1 This specific weld area will not fully comply with ASME-BPE due to accessibility limitationsNOTE 2 This length is 125rdquo minimum for all Weld End process connections and nominally 0312rdquo for Hygienic Ferrule process connectionsNOTE 3 For typical installation orientation for each configuration see the SWE Installation Manual at wwwBurnsEngineeringcomSWE-Installationpdf

This SWE Reduced Body design offers a process tube size reduced from a larger body to support installation in frac12rdquo and frac34rdquo line sizes The reduced style of the body provides excellent immersion and ensures component drainability and minimal pressure drop This design can be configured as concentric or eccentric for ease of installation (NOTE 3) All SWE products include certification of wetted surface materials and surface finish

All dimensions in inches

17

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 19: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Sanitary Elbow (SWE)frac12rdquo and frac34rdquo Line Size Ordering Information

SWE Sanitary Elbow ThermowellsElbow Size (Tube OD)

-050 12 Elbow-075 34 Elbow

InletOutlet Orientation (See illustrations on page 17)

C ConcentricE0 0deg EccentricE90 90deg EccentricE180 180deg EccentricE270 270deg Eccentric

Process Connection

A Hygienic Ferrule both inlet and outletB Weld Ends both inlet and outletC Hygienic Ferrule inlet connection Weld Ends outlet connectionD Weld Ends inlet connection Hygienic Ferrule outlet connection

Material Type

06 316L Stainless Steel (Per ASME-BPE Chemical Composition)Bore Depth

25 25 inches45 45 inches60 60 inches

Bore Diameter OD ID

A 0375 0260

Sensor Connection

A 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface Finish

M32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

External Surface Finish

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish maxE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolish

lsquoX3rsquo Dimension Nominal

07510

Tolerance

+0005-0003Other Bore Diameters are available Please contact our Application Engineering group for available selections

Basic order code (specify all)

12 Elbow

34Elbow

0935

Weld End Inlet Process Connection (B amp D)

1063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 1438bore depth + 1438

Hygienic Ferrule Inlet Process Connection (A amp C)

12 Elbow

34Elbow

09351063

lsquoX1rsquo Dimension plusmn0063 lsquoX2rsquo Dimension Nominal

bore depth + 047bore depth + 035

18

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 20: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SWT Standard Sanitary Thermowell19

(125) Process Immersion Length

lsquoX1rsquo

Process Connection(shown with 12rdquo cap)

Extension Connection (shown with 12rdquo Cap B)

Oslash (05)

OD

ID

lsquoArsquo Bore Depth

lsquoArsquo Bore Depth = Extension Length + Process Immersion - X1lsquoArsquo Bore Depth = lsquoCrsquo Compressed Sheath Length

SWT-Standard Sanitary Thermowell

(125) (125) (125)

Extension Connection 12rdquo Code B

Process Connection 1 12 Code T15Extension Connection 1 12rdquo Code C

Process Connection 1 12 Code T15

Extension Connection 1 12rdquo Code C

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 12 Code T05

Extension Connection 12rdquo NPT Code A

Process Connection 1 12 Code T15

The Process Connection is also available in 2rdquo 2 12rdquo 3rdquo and 4rdquo sizes

(20)

(20)

Extension and Process Connection Types

Oslash 1315rdquo with 1125rdquo Wrench Flats

Oslash 1315rdquo with 1125rdquo Wrench Flats

SWT (Standard Sanitary Thermowells) are used in applications that require sensor removal during process operation The SWT is designed to be used with the S60 and S65 sanitary spring loaded sensors to create a complete sanitary assembly Simply match the thermowell bore depth lsquoArsquo to the sensor compressed sheath length lsquoCrsquo The SWT can also be used with our Series 100 200 and 300 spring loaded sensors by selecting the frac12 inch NPT threaded extension connection code lsquoArsquo

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 21: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SWT Standard Sanitary Thermowell20

125

125

250

250

300

300

500

500Specify

Specify

Pro

cess

Im

mer

sion

Len

gth

012rdquo Immersion Length + 188

025rdquo 300

025rdquo Immersion Length + 175

012rdquo 688

025rdquo 675

012rdquo 488

025rdquo 475

012rdquo 438

025rdquo 425

012rdquo 313

12 NPT Threaded Extension Connection (A)lsquoX1rsquo Dimension Nominal Bore Depth Nominal

125

125250

250

300

300

500

500

Specify

Specify 012rdquo Immersion Length + 113

Pro

cess

Im

mer

sion

Len

gth

lsquoX1rsquo Dimension Nominal Bore Depth Nominal

025rdquo 225

025rdquo Immersion Length + 100

012rdquo 613

025rdquo 600

012rdquo 413

025rdquo 400

012rdquo 363

025rdquo 350

012rdquo 238

Hygienic Ferrule Extension Connection (B amp C)

Note The SWT includes certification of wetted surface materials finish and electropolish when applicable

Process Connection (Used with tube sizes)-T05 12 Hygienic Ferrule 12 34-T15 1 12 Hygienic Ferrule 1 1 12 -T20 2 Hygienic Ferrule 2-T25 2 Hygienic Ferrule 2-T30 3 Hygienic Ferrule 3-T40 4 Hygienic Ferrule 4

Material Type03 316 Stainless Steel06 316L Stainless Steel

Process Immersion Length

0250 25 inches0300 30 inches0400 40 inches0450 45 inches0600 60 inches

Specify Process Immersion Length in Inches (12rdquo = 1200)

Bore DiameterOD ID

A 0375 0260B 0375 0305C 0250 0194D 0188 0144E 0455 0385

Extension ConnectionA 12 NPT Threaded ConnectionB 12 Hygienic FerruleC 1 12 Hygienic Ferrule

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

125125

Extension Length20

025rdquo025rdquo025rdquo012rdquo025rdquo

Dimension X1Tolerance+0005-0003rdquo

plusmn0010rdquo

+0005-0003rdquoplusmn0005rdquo

+0004-0000rdquo

F 0188 0135 012rdquo plusmn0005rdquo

Basic Ordering Codes

SWT

SWT Sanitary Thermowell Standard

Ordering Information

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 22: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNx Non-Intrusive AssembliesSNI SNS and SNR

21

Sanitary Non-intrusive Application The Sanitary Non-Intrusive (SNx) is an in-line RTD or Thermocouple ideally suited for use in small diameter process lines where direct immersion temperature probes cannot be used but where temperature measurement is required The in-line design eliminates the need for direct probe insertion into the product flow where viscosity and flow rate can affect accuracy and structural integrity

Product Overview

13

SNx family

The SNS provides a shorter 5rdquo installation length and flow tube diameters from frac12rdquo to 4rdquo

The SNI model is available in flow tubediameters as small as frac14rdquo with an overall length of 8rdquo

If you donrsquot see something that meets your needs give us a call and wersquoll customize for your specific application

The SNR incorporates a removable sensor for ease of periodic calibration and installs with a hygienic clamp union It is available in flow tube sizes from 12rdquo to 4rdquo

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 23: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Operating RangeAll SNx designs provide a temperature measurement range of -50ordmC to 200ordmC The ambient temperature limit is dependent on external configuration choices such as connection heads cables and use of a local transmitter When the ambient temperature can deviate from the process temperature by more than a 70degC delta the use of insulation over the installed sensor assembly can help maintain measurement accuracy

Response Time The non-intrusive nature of the SNx design can be slower to respond to temperature variations than immersion style sensors Insulating the measurement location will improve accuracy and responsiveness The SNx is designed to ensure sensitivity to the process fluid providing a time response of 12 seconds to 632 of a step change in temperature For more information regarding the time response measurement of non-intrusive surface style devices see the Burns technical paper on measuring response time of surface sensors at httpwwwburnsengineeringcomtech-papers

Installation ConsiderationsTo ensure drainability and measurement accuracy the SNx should be mounted in a vertical section of tubing where the process fluid is flowing upward If the process tubing is always completely full such that the fluid will be in contact with the entire inside diameter of the SNx sensor alternate installation orientations can be effective Note that the SNS due to the short length of the process tubing is marked with the required flow direction to ensure proper performance The design of the SNI and SNR allow flow in either direction

SNx Non-Intrusive AssembliesSNI SNS and SNR

22

Selection Guide

Process Considerations For process systems where space is a constraint the SNS (short) model reduces the flow tube length from 8rdquo to 5rdquo without reducing performance

When accuracy and repeatability are a foremost consideration the SNR provides ultimate flexibility The sensor is designed to be removed for calibration or replacement when necessary Sensor design supports connection head with terminal block local transmitter or extended cable installations

All three SNx designs are available with hygienic connections or weld-ends for connection to the process tubing BPE compliant and designed to meet the SSI 3-A standard these sensors are an excellent solution for the Sanitary process industry and an effective alternative when immersion sensors are not an option

15

Process Connection Weld End

15

Process Connection Cap End

Process Connection Types

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 24: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNI Non-IntrusiveSpecification

Shown with 9PN Connection Head(See page 24 for other options)

Process ConnectionShown with Hygienic Ferrule(See sheet 2 for other options) Serial amp Heat Numbers

Sensor LocationOuter Tube Oslash

Process TubeOslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

Internal Surface Finish

SNI Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length

raquo For assemblies with hygienic ferrules the OAL is 80 inches

raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNIpdf

23

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 25: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNI Non-IntrusiveOrdering Information

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNI- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

24

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 26: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNS Non-Intrusive ShortSpecification

Shown with 9PN Connection Head(See page 26 for other options)

Process ConnectionShown with Hygienic Ferrule

(Weld-Ends Optional)

Serial amp Heat Numbers

Sensor Location

Outer Tube Oslash

Process Tube Oslash lsquoArsquo

Overall Length lsquoOALrsquo plusmn 0063

Direction of flow

Length lsquoDrsquo

Internal Surface Finish

SNS Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 50 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 65 to 725 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNSpdf

25

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 27: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNS Non-Intrusive ShortOrdering Information

26

Connection Head (NOTE 1)1EN Cast Iron Epoxy Coated NET Solution2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN1 No Connection Head 12 NPT BushingN2 No Connection Head 12 NPSM BushingN3 No Connection Head with 38-24 UNF ThreadsNA Cable Design 120 Length Nylon Spring Standard See page 40 for other options

Sensor StyleSNS- Sanitary Non-Intrusive

RTD Accuracy

05 Precision RTD +-005 of resistance at 0 degrees C10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Lead Element ConfigurationA Three Wire Single B Four Wire Single C Three Wire Dual

Thermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

for Weld EndsOverall Length

0250 0250 0032 125 1750500 0500 0065 125 175

0750rdquo0570 0065 2 175 1000 1000 0065 3 1751250 1250 0065 3 175

0065 3 1750051002 0 2000 0065 4 175052 0 2500 0065 4 175

3000 3000 0065 6 2004000 4000 0083 6 213

Process Tube Material

-06 316L-20 AL6XN

Internal Finish

A 32 Ra Mechanical FinishB 10 Ra Electropolish

SN tandard Pipe Finish Mechanical Not Available with 3A

External Finish

1 Sand Blasted2 Bright Mechanical (32 Ra Surface Finish)

Process Connection Fitting

elurreF cineigyH CnoitcennoC ssecorP oN sdnE dleWN

Process Connection Size C Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process Connection Material

-06 316L SS-20 AL6XN

Weld Ends Leave Blank

Process Tube Oslash A Wall Thickness Outer Tube OslashProcess Connection

Length D for Weld Ends650650

650650650650650650700725

1500rdquo

Example Part Number SNS-10A9PN1000-06A1C150-06

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 28: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive RemovableSpecification

Shown with 9PN Connection Head(See page 28 for other options)

Heat Numbers

Instrument Connection 05rdquoHygienic Union with Clamp

Outer Tube Oslash

Process Tube Oslash

Internal Surface Finish

25

Overall Length lsquoOALrsquo plusmn 0063

Length lsquoDrsquo

SNR Specifications

120 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

Precision 004

Standard 008

bull General Specifications raquo See page 4 of this catalog

bull Removable Sensor raquo Details see pages 29 and 30

bull Process Connections raquo Hygienic ferrules for hygienic clamp union connection

raquo Weld-ends squared off to support automatic weld process

bull Installation Length raquo For assemblies with hygienic ferrules the OAL is 80 inches raquo For assemblies with weld-ends to support automatic welding the OAL range is 85 to 925 inches based on

the process tube size See ordering information table under lsquoProcess Tube Oslashrsquo

All dimensions in inches

Link to Drawing wwwBurnsEngineeringcomSNRpdf

27

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 29: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive RemovableOrdering Information

Sensor StyleSNR- Sanitary Non-intrusive Removable

RTD Accuracy10 Standard RTD +-010 of resistance at 0 degrees C

Thermocouple TypeE ChromelConstanian (leadwire colors = +purple -red)

)der- etihw+ = sroloc eriwdael( nainatsnoCnorIJ)der- wolley+ = sroloc eriwdael( lemulAlemorhCK

)der- eulb+ = sroloc seriwdael( nainatsnoCreppoCT

RTD Element Lead ConfigurationA Three Wire Single B Four Wire Single

Thermocouple Junction ConfigurationD Single Ungrounded

for Weld EndsOverall Length

Material

-06 316L-20 AL6XN

Internal Finish

M32 32 Ra Mechanical FinishE10 10 Ra Electropolish

Process Connection Fitting

)elurreF cineigyH( paC yratinaSWeld Ends No Process Connection

C N

Process Connection Size Compatible with tube sizes

0570 005021050150 1 12 1000 1500

00022002250 2 12 2500

0003300300044004

Weld Ends No Process Connection Leave Blank

Process TubeFlow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

Length D for Weld Ends

Connection Head (NOTE 1)2EN Aluminum Epoxy Coated NET Solution5EN Aluminum Epoxy Coated NET Solution9PN Polypropylene White NET Solution14SN Stainless Steel NET Solution16AN Mini Aluminum Epoxy Coated NET Solution19AN Aluminum with LED indicator NET Solution20PN Plastic with LED indicator NET Solution21SN Stainless Steel with LED indicator NET Solution22AN Aluminum with LCD indicator NET Solution23PN Plastic with LCD indicator NET Solution24SN Stainless Steel with LCD indicator NET SolutionN2 No Connection Head 12 NPSM BushingNA Cable design 120 Length Nylon Spring Standard See page 40 for other options

Example Part Number SNR-10A20PN2000-06E10C200

0500 0500 0065 125 15 22535-1 22536-1 22537-1 175 850rdquo0750 0750 0065 2 15 22535-1 22536-1 22537-1 175 850rdquo1000 1000 0065 3 2188 22535-2 22536-2 22537-2 175 850rdquo1500 1500 0065 3 15 22535-1 22536-1 22537-1 175 850rdquo2000 2000 0065 4 2188 22535-2 22536-2 22537-2 175 850rdquo2500 2500 0065 4 15 22535-1 22536-1 22537-1 175 850rdquo3000 3000 0065 6 2188 22535-2 22536-2 22537-2 200 900rdquo4000 4000 0083 6 2188 22535-2 22536-2 22537-2 213 925rdquo

Outer Tube OslashWall Thickness

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

28

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 30: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Installation

The SNR sensor is uniquely designed to reduce stem conduction and ensure maximum thermal contact with the process and is removable for periodic calibration Available with extended cable or wires for connection head wiring the SNR sensor will provide confident non-intrusive temperature measurements

SNR Non-Intrusive Removable ReplacementSensor Installation

Sensor installation with connection head Sensor installation with cable option

Removable Sensor

Housing

Process TubeOuter Tube Oslash

Flow Tube Diameter

Bore Depth

RTD wCable

RTD wHead Thermocouple

0500 0500 125 15 22535-1 22536-1 22537-1 0750 0750 2 15 22535-1 22536-1 22537-1 1000 1000 3 2188 22535-2 22536-2 22537-2 1500 1500 3 15 22535-1 22536-1 22537-1 2000 2000 4 2188 22535-2 22536-2 22537-2 2500 2500 4 15 22535-1 22536-1 22537-1 3000 3000 6 2188 22535-2 22536-2 22537-2 4000 4000 6 2188 22535-2 22536-2 22537-2

FOUR WIRESINGLE

THREE WIRESINGLE

ElementLead Wire Configuration

THERMOCOUPLE

Wire Guage Size

Cable Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 26 AWG

Wire Designs (RTD)3 Conductor Cable 22 AWG

4 Conductor Cable 24 AWG

Thermocouple Designs2 Wire Single Thermocouple 20AWG

29

Replacement Sensor Part Number

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 31: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SNR Non-Intrusive Removable Replacement Sensor

Ordering Information

NOTE 1 To determine the correct Bore Depth code see the sensor illustration and the table on page 29 relating process tube size bore depth and replacement sensor part number NOTE 2 For 3 wire designs ndash Order the actual installed length To maintain stated RTD accuracy 3 wire Single designs with LYgt324rdquo and 3 wire dual designs with LYgt 120rdquo cannot be shortened NOTE 3 For replacement thermocouple sensor in an assembly with a connection head choose 6rdquo leads ndash code lsquo006rsquo

Replacement RTD for Assemblies with Cable22535-

Bore Depth1 15 Inches

(NOTE 1)

(NOTE 2)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLYrdquo Cable Length in Inches120 120 inches240 240 inches Specify Length (060 = 60 Inches)

Replacement RTD for Assemblies with Connection Head22536-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationA 3 WireB 4 Wire

ldquoLrdquo PFA Sheath Length in Inches006 6 inches (NOTE 3)012 12 inches024 24 inches

22536-1B012

Replacement Thermocouple for Assemblies with Connection Heads or Cable22537-

Bore Depth1 15 Inches

(NOTE 1)

2 2188 Inches

Element ConfigurationE Type lsquoErsquoJ Type lsquoJrsquoK Type lsquoKrsquoT Type lsquoTrsquo

ldquoLYrdquo Cable Length in Inches006 6 inches120 120 inches Specify Length in Inches

22537-1J006

30

Link to Drawing wwwBurnsEngineeringcom22535

Link to Drawing wwwBurnsEngineeringcom22537

To identify the proper replacement sensor measure the sensor

length to determine bore depth code in ordering tables

Link to Drawing wwwBurnsEngineeringcom22536

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 32: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Specifications

31

Note The SPA amp SPS include certification of wetted surface materials finish and electropolish when applicable

Process Sheath Length

Process Sheath Length

lsquoErsquo Fitting Length

lsquoGrsquo O-Ring Location

lsquoGrsquo O-Ring Location

lsquoErsquo Fitting Length

O-ring

Cap Nut(225)

Leads (6 inches std)

(20)

(15)

Cable Length (120 std)

Shown with Cable Design (NA)Nylon Spring Strain Relief Standard

SPA-Ingoldreg Port with 15deg angle fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

SPS-Ingoldreg Port with straight fitting 14rdquo Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

Shown with 12rdquo NPT (N1)Sensor to Head Connection

Finish Exception On Angle Only Polish Weld Bead

Cap Nut Dimensions

C (20)

B

A

(015)Optional SD40 Heavy Duty Sheath

Oslash (05)Oslash (025)

The Ingoldreg port fitting offers a clean and safe instrumentation mounting configuration while maintaining the ease-of-use of a removable sensor The Burns design has the flexibility for specifying the O-ring location to minimize the ldquodeadrdquo space allowing for the cleanest possible installation The Ingoldreg solution is ideal for sanitary vessels and fermentation applications

SPA amp SPS Application SPA amp SPS Specifications

35 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

All dimensions in inches

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 33: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SPA amp SPS Direct Immersion Ingoldreg Port Sensor

Ordering Information

32

Sensor Style Min Process Sheath Length Max Process Sheath Length Sheath Length TolerancePA- Ingoldreg Port with 15deg Angle Fitting 14rdquo Sheath 15 360 +- 0125rdquoPS- Ingoldreg Port with Straight Fitting 14rdquo Sheath 15 360 +- 0125rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees CThermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction ConfigurationD Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

Process Sheath Length (Note sensor type minimum amp maximum values above)

0250 250 inches0400 400 inches0825 825 inches1200 1200 inches

Specify Process Sheath Length in Inches

Connection Head SensorHead Connection-1C Cast Iron Black Element 12 NPT

-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum Gray 12 NPT-2E Aluminum Epoxy Coated 12 NPT

-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT

-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT

-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT

-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na-NB No Connection Cable Design 120 Quick Disconnect Full Assembly (NOTE 1) na-NC No Connection Cable Design Quick Disconnect Replacement Sensor (NOTE 1) na

E Fitting Length30 30mm (118)40 40mm (157)48 48mm (189)50 50mm (197)52 52mm (2047)55 55mm (217)60 60mm (236)

Specify E in millimetersG O-Ring Location

079 0079 inches188 0188 inches

Specify in decimal inches (250 = 025 375 = 0375)O-Ring (NOTE 1)

1 EPDM O-Ring FDA Compliant 250degF2 Vitonreg O-Ring FDA Compliant 400degF3 Silicone Rubber O-Ring FDA Compliant 400degF4 Buna N O-Ring FDA Compliant 275degFN None No O-Ring required na

Cap Nut A B C

3 Burns Standard 055 070 1358N None na na na

Wetted Surface FinishM32 32 Ra mechanical finish maxM25 25 Ra mechanical finish maxM20 20 Ra mechanical finish maxM15 15 Ra mechanical finish maxE32 32 Ra mechanical finish max with electropolishE25 25 Ra mechanical finish max with electropolishE20 20 Ra mechanical finish max with electropolishE15 15 Ra mechanical finish max with electropolishE10 10 Ra mechanical finish max with electropolish

Maximum Temperature Limit

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator

-20PN Plastic with LED Indicator NET Solution

12 NPT12 NPSM12 NPT

12 NPSM

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

NOTE 1 All O-Rings are FDA Compliant per 21 CFR 1772600

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 34: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

SFM Sanitary Flush Mount33

lsquoXrsquo Length

19901999

Oslash(25) 316 Stainless Steel

Shown with 38rdquo UNF (N3)Sensor to Head Connection

Oslash

(10)

7ordm 30rsquo8ordm 30rsquo

(20)Leads (60 std)

SFM-Flush Mount Available with cable 12rdquo NPT 38rdquo UNF and 12rdquo NPSM head connection

WettedSurfaceFinish

(153)

25652545Oslash

(075)

7ordm 30rsquo8ordm 30rsquo

2 58-16 UN 2B

Adaptor Backing Nut Gasket

0063

25102500Oslash

20102000

Oslash

(1125)

Oslash (0625)

2 58-16 UN 2A

The SFM is designed for tanks that have a mixer blade or other obstruction that prevents the use of a standard immersion sensor A backing nut and adaptor allow easy installation and removal

SFM Application SFM Specifications

150 seconds

004

Precision 001

Standard 010

Time Constant

Maximum time to reach 632 of a step change in temperature in

water flowing at 3 fps

RTD Repeatability

Maximum change in resistance at 0degC after 10 cycles over the full

temperature range

RTD Long Term Stability

Maximum change in resistance at 0degC after 1000 hours at 200degC

RTD Hysteresis

Maximum error at the mid point of the operating temperature

range (Example 004 over a 250degC range = 010degC)

See page 4 for General and Thermocouple Specifications

Precision 004

Standard 008

Specifications

All dimensions in inches

All dimensions in inches

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 35: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

SFM Sanitary Flush Mount34

Sensor StyleFM- Flush Mount 2 12rdquo

RTD (Accuracy)10 Standard RTD +- 010 of resistance at 0 degrees C05 Precision RTD +- 005 of resistance at 0 degrees C Thermocouple (Type)E ChromelConstantan (leadwire code = purple+ red-)J IronConstantan (leadwire code = white+ red-)K ChromelAlumel (leadwire code = yellow+ red-)T CopperConstantan (leadwire code = blue+ red-)

RTD Element Lead ConfigurationA Three Wire Single B Four Wire SingleC Three Wire DualThermocouple Junction Configuration

D Single UngroundedE Single GroundedF Dual UngroundedG Dual Grounded

lsquoXrsquo Length 0218 0218 inches0399 0399 inches0486 0486 inches

Specify lsquoXrsquo Length in Inches

Connection Head (NOTE 1) SensorHead Connection-1C Cast Iron Black Enamel 12 NPT-1EN Cast Iron White Epoxy Coated NET Solution 12 NPSM-2A Aluminum 12 NPT-2E Aluminum Epoxy Coated 12 NPT-2EN Aluminum Epoxy Coated NET Solution 12 NPSM-5A Aluminum 12 NPT-5E Aluminum Epoxy Coated 12 NPT-5EN Aluminum Epoxy Coated NET Solution 12 NPSM-9P Polypropylene White 12 NPT-9PN Polypropylene White NET Solution 12 NPSM-14S Stainless Steel 12 NPT-14SN Stainless Steel NET Solution 12 NPSM-16AN Miniature Aluminum NET Solution 38 UNF

-N1 No Connection Bushing 12 NPT-N2 No Connection Bushing NET Solution 12 NPSM-N3 No Connection No Bushing NET Solution 38 UNF-NA No Connection Cable Design 120 Nylon Spring Standard na

Wetted Surface Finish

Adaptor (all adaptor surfaces are non-wetted)12N

304 Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2B316L Stainless Steel 2 12rdquo schedule 40 pipe 2 58-16 UN 2Bnone

Backing Nut (all nut surfaces are non-wetted)1N

Backing Nut 303 Stainless Steel 2 58-16 UN 2Anone

Teflon Gasket (Includes certifcate of conformance)23N

Teflonreg Gasket FDA 21 CFR paragraph 1771550Inertexreg SQ-S USP Class VInone

-19A Aluminum with LED Indicator-19AN Aluminum with LED Indicator NET Solution-20P Plastic with LED Indicator-20PN Plastic with LED Indicator NET Solutiontrade

12 NPT12 NPSM12 NPT12 NPSM

M32 32 Ra mechanical finish maxM20 20 Ra mechanical finish max

(Not currently available with electropolish)

S

(Leave blank if not required)

Options TransmitterSee pages 35 - 39

Basic Order Codes

Ordering Information

NOTE 1 For full descriptions see page 40 or wwwBurnsEngineeringcomCon-Headspdf

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 36: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Accessories and Option Codes35

lsquoLYrsquo Lead Length (60 std)

(15)

lsquoLYrsquo Cable Length (120 std)

lsquoLMrsquo Cable Material(PTFE insulated std)

L Lead Wire OptionsLead Wire Length (Y option)

Y_____ Specify lead wire length in one inch incrementsExample For a 12 inch Y length specify 012 For a 15 foot Y length specify Y180Cable designs Minimum 120 inches (Y012) Maximum 3000 inches (Y300)Lead wire designs Minimum 30 inches (Y003) Maximum 360 inches (Y036)

Lead Wire Configuration (C option) Available only when -NA cable design is specified

C20 Shielded Cable ( Stainless Steel braided shield)C23 Shielded Cable ( Kaptonreg polyimide film foil shield with drain wire)C30 Cable with Stainless Steel Overbraid

No Strain ReliefFS00

Vinyl Boot FS02

Stainless Steel SpringFS03

Nylon Dome FS04

Polyolefin FS05

90deg

15

Polyolefin wBendFS06

F Fitting OptionsStrain Relief Options (S option) available only when -NA cable design is specified

S00 No Strain Relief RequiredS02 Vinyl BootS03 Stainless Steel SpringS04 Nylon DomeS05 Polyolefin Adhesive LinedS06 Polyolefin Adhesive Lined with 90deg Bend

Leadwire Options

Strain Relief Options

All dimensions in inches

Cable Gland Options

H Head Options

Cable Gland Options (C option)

C01 Nylon Cable Gland 14 NPT 0080 - 0200C02 Nylon Cable Gland 12 NPT 0236 - 0473C03 Nylon Cable Gland 34 NPT 0472 - 0708C04 Nylon Hubbell 12 NPT 0250 - 0375C05 Nylon Hubbell 12 NPT 0187 - 0250

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 37: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Accessories and Option Codes

Tagging OptionsM Miscellaneous Options

T01 Paper Tag with Tag Number (sensor assembly)T02 Stainless Steel Tag with Tag Number (sensor assembly)T24 Paper Tag with Time Constant (used with S40 HTST sensors only)

Sensor Tagging Options

36

Cable for Remote Mount OptionsH Head Options

LeadwireCable Length (L option)

L012 12 inches (1 foot)L060 60 inches (5 feet)L120 120 inches (10 feet)

Specify in one-inch increments

Material01 PTFE02 Fiberglass

Polyimide Film

Configuration01 Individual Insulated Lead Wires10 Cable20 Shielded Cable - Stainless Steel Braided Shield21 Shielded Cable - Copper Braided Shield23 Shielded Cable ndash PolyesterAluminum Foil Shield with Drain Wire30 Cable with Stainless Steel Overbraid

03

Calibration OptionsBurns Engineering is a NVLAP accredited (Lab code 200706-0) temperature calibration facility

C Calibration Options with Calilbration Report and R vs T Table

Units Report and Table

I Degrees C

F Degrees F

Range of Calibration

25 4 Points ordmC -38 0 50 100 or ordmF -36 32 122 212F

26 4 Points ordmC -38 0 100 200 or ordmF -36 32 212 392

35 3 Points ordmC 0 50 100 or ordmF 32 122 212

36 3 Points ordmC 0 100 200 or ordmF 32 212 392

Reports Options

R10 Certificate of Calibration for RTD at 0degCR11 Certificate of Conformance with Certified DrawingR12 Certificate of Calibration for Thermocouple at 100ordmC

For all Series S sensors and thermowells with a wetted surface the heat numbers of all wetted materials will be electro-etch marked on the sensor andor thermowell extension A Material Certification of wetted surfaces (SR01) (WE04) and a certificate of surface finish (SR03 or SR05) (WE06 or WE14) will be included automatically A Certificate of Conformance will also be included for O-rings used in the SPS and SPA designs (SR12) No option codes are required for the above The options below are available only if requested at time of order

Documentation

S Sheath Options

Certifications (R option)

R10 Certification that no polishing compound was used on the sensor assembly

W Thermowell Options

Testing and Documentation (E option)

E10 Certification that no polishing compound was used on the ThermowellE16 Positive Material Identification (PMI)

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 38: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Transmitter OptionsT51 and T55 Transmitters with TP05 Programmer

DescriptionLoop powered DIN B Form RTD and thermocouple temperature transmitters for head mounting Model T51 and T55 transmitters carry FM CE and CSA approvals allowing installation and use in a variety of applications

Features and Benefitsraquo Vibration and shock resistance raquo Configurable to fit your application raquo Provides RTD ldquomatchingrdquo capability for improved system accuracy (T55) raquo HART programmable (T55)raquo 005 accuracy raquo PC programmable with TP05 interface and communication software raquo Full input-output isolation raquo Configurable via a PC or HART Communicator raquo RTD or Thermocouple Inputsraquo Outputs 2-wire 4-20mA

Communication via USB PortUsing TP05 the communication between the programming unit and the PC is now carried out by way of a USB port TP05 is fully compatible with PCs running Windows 2000 XP 7 and Vista operating systems

Quick Set-UpThe programming module is simple and quick to use Once the driver has been installed the user only needs to connect the module to the PC and programming can start Power is supplied from the USB port

Online ProgrammingEither transmitter model can be configured independent of the process or alternatively directly in the process while connected to your control system

TP05 Package IncludesInterface Device Software with drivers and Communication cable

For T51 and T55 full specifications and features see the Temperature Transmitter Catalog

httpwwwburnsengineeringcomdocumentcatalogsTemperatureTransmitterspdf

13

T51 RTD TransmitterT55 RTD Transmitter Matching Capabilities HART Communication

Calibration Type

M Transmitter and Sensor matched for improved performance (Only available with T55 Transmitter)

(blank) Not matched

Temperature Range

Tmin to Tmax Tmin = Temperature for 4mA outputTmax = Temperature for 20mA output

Temperature Units

C Degrees CelsiusF Degrees Fahrenheit

13

TP05 Programming Module

37

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 39: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Transmitter OptionsT16 Miniature Transmitter with TP16 Programmer

DescriptionThe T16 is a miniature loop-powered RTD temperature transmitter integrated into a compact aluminum connection head The T16 is ideal for applications where additional signal enhancement is required and space is limited such as process skids and small reactor vessels

Features and Benefitsraquo Input 2 or 3 wire PT100 RTD raquo Temperature Range -200degC to 500degC raquo Minimum Span 25degC raquo Output 2 wire current loop 4-20mA raquo Supply Voltage 8 ndash 30 Vdc raquo Operating Range -40degC to 85degC raquo Size 205rdquo x 197rdquo Conduit Port frac14 NPT raquo Sensor Port 38-24 UNF

TP16 Programming Module

DescriptionThe T16 is easily programmed with a PC using the Burns TP16 Programming Module and communication software

For T16 full specifications and features see the T16 Specification page or the Burns Website

httpwwwburnsengineeringcomdocumentcatalogst16pdf

13

38

13 CONNECTION HEAD COVER

SILICONE RUBBER GASKET

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 40: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Sanitary Accessories39

Burns Sanitary Adaptors allow you to modify any existing NPT connection to a hygienic connection giving you the capability to select and use the Series S standard and NET Solutiontrade sensors with existing systems The Sanitary Adaptor is available in several different connection sizes and lengths ranging from 15 to 60 inches

Overall Length plusmn0125

(05)

12 NPTProcess Connection

(lsquoNrsquo Adaptor Length)

Extension Connection

316 Stainless Steel

12 inch is nominal thread engagement for the 12rdquo NPT thread size

All dimentions in inches

SAA Sanitary AdaptorExtension Connection Size (Used with tube sizes)

-05

3 3

-1512 12 34

-201 12 1 1 12

-252 2

-302 12 2 12

Extension Connection Material03 316 Stainless Steel06 316L Stainless Steel

lsquoNrsquo Adaptor Length

-0150 150 inch lsquoNrsquo Length (OAL = 200 inches)-0175 175 inch lsquoNrsquo Length (OAL = 225 inches)-0300 300 inch lsquoNrsquo Length (OAL = 350 inches)

Specify lsquoNrsquo Length in Inches

4 -40 4

Minumum length 10 inches -100 maximum length 60 inches -600

Adaptors

Consult the factory

Outlet Size

Line Size

ID

OD

D1

Hygienic Gasket

Hygienic Clamp Joint Tees

Hygienic Clamp

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 41: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

3 34

2 14

Head to SensorConnection

12rdquo NPT

4 Digit LED

40

Connection Head Descriptions

Plastic NEMA type 4X weather proof connection head with 4 digit LED Indicator For use with single sensing elements only Requires a DIN B sized transmitter for display

Cast aluminum connection head with 4 digit LED Indicator FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single sensing elements only Requires a DIN B sized transmitter for display

Standard EnclosuresBurns Engineering offers an extensive array of connection heads to complement the sensor and its operational environment Each connection head can be specified with traditional NPT threads or NET Solutiontrade NPSM threads For full descriptions of all Burns Connection Heads see wwwBurnsEngineeringcomCon-Headspdf

Enclosures with LED IndicatorBurns Engineering offers loop powered and battery powered Indicators which incorporate a high efficiency display in an enclosure The unit is microprocessor based and set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure It can be driven by the Burns Model T51 or T55 transmitters which sit in the same head underneath the indicator making a compact efficient package Or it can be configured to run from any 4 to 20 mA source and display the desired process variable Contact the factory for details on the battery powered option

Burns 20P (12rdquo NPT head to sensor connection)

Burns 20PN (12rdquo NPSM head to sensor connection)

Burns 19A (12rdquo NPT head to sensor connection)

Burns 19AN (12rdquo NPSM head to sensor connection)

5

4 12

Head to SensorConnection

12rdquo NPT

4 Digit LED

12rdquo NPT

5

3 12

34rdquo NPT

Head to SensorConnection

2

3 12

3 34

34rdquo NPT

Head to SensorConnection

14rdquo NPT Head to SensorConnection

2

3 34

34rdquo NPT

Head to SensorConnection

34rdquo NPT

Head to SensorConnection

4 18

5 12

Cast iron weather proof connection head NEMA type 4 enclosure For use with single element three wire dual element RTDs and DIN B sized transmitters

Polypropylene weather proof NEMA type 4X connection head For use with single element three wire dual element RTDs and DIN B sized transmitters

316 stainless steel connection head CSA and FM rated as explosion proof Class I Div 1 Group BCD dust ignition proof for Div II Group EFG NEMA 4X For use with single and dual sensing element and DIN B sized transmitters

Miniature aluminum connection head For use with single element RTDs

Cast aluminum weather proof connection head NEMA type 4X enclosure For use with single element three

Cast aluminum connection head FM rated as explosion proof Class I Div 1 Group ABCD Class II Div 1 Group EFG Class III Div 1 NEMA 4X For use with single and dual sensing element DIN B sized and model TL transmitters

Burns 16AN(38rdquo-24 UNF head to sensor connection)

wire dual element RTDs and DIN B sized transmitters

Burns 2A (12rdquo NPT head to sensor connection)

Burns 2E (epoxy coated 12rdquo NPT head to sensor connection)

Burns 2EN (epoxy coated 12rdquo NPSM head to sensor connection)

Burns 3A (12rdquo NPT head to

sensor connection wwaterproof kit)

Burns 3E (epoxy coated 12rdquo NPT head to sensor connection w

waterproof kit)

Burns 5A (12rdquo NPT head to

sensor connection)

Burns 5E (epoxy coated 12ldquo

NPT head to sensor connection)

Burns 5EN (epoxy coated 12ldquo NPSM head to sensor connection)

Burns 1C (12rdquo NPT head to sensor connection)

Burns 1EN (12rdquo NPSM head to sensor connection)

Burns 14S (12rdquo NPT head to sensor connection)

Burns14SN (12rdquo NPSM head to sensor connection)Burns 9P (12rdquo NPT head to sensor connection)

Burns 9PN (12rdquo NPSM head to sensor connection)

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 42: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

41

Resistance vs Temperature

R vs T degC

0 1 2 3 4 5 6 7 8 9

200 17586 17622 17659 17696 17733 17769 17806 17843 17879 17916

190 17217 17254 17291 17328 17365 17402 17438 17475 17512 17549

180 16848 16885 16922 16959 16996 17033 17070 17107 17142 17180

170 16477 16514 16551 16589 16626 16663 16700 16737 16774 16811

160 16105 16143 16180 16217 16254 16291 16329 16366 16403 16440

150 15733 15770 15807 15845 15882 15919 15956 15994 16031 16068

140 15358 15396 15433 15471 15508 15546 15583 15620 15658 15695

130 14983 15021 15058 15096 15133 15171 15208 15246 15282 15321

120 14607 14644 14682 14720 14757 14795 14833 14870 14908 14946

110 1429 14267 14305 14343 14380 14418 14456 14494 14531 14569

100 13851 13888 13926 13964 14002 14040 14078 14116 14154 14191

90 13471 13509 13547 13585 13623 13661 13699 13737 13775 13813

80 13090 13128 13166 13204 13242 13280 13318 13357 13395 13433

70 12708 12746 12784 12822 12861 12899 12937 12975 13013 13052

60 12324 12363 12401 12439 12478 12516 12554 12593 12631 12669

50 11940 11978 12017 12055 12094 12132 12171 12209 12247 12286

40 11554 11593 11631 11670 11708 11747 11786 11824 11863 11901

30 11167 11206 11245 11283 11322 11361 11400 11438 11477 11515

20 10779 10818 10857 10896 10935 10973 11012 11051 11090 11129

10 10390 10429 10468 10507 10546 10585 10624 10663 10702 10740

0 10000 10039 10078 10117 10156 10195 10234 10273 10312 10351

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 10000 9961 9922 9883 9844 9804 9765 9726 9687 9648

-10 9609 9569 9530 9491 9452 9412 9373 9334 9295 9255

-20 9216 9177 9137 9098 9059 9091 8980 8940 8901 8862

-30 8822 8783 8743 8704 8664 8625 8585 8546 8506 8467

-40 8427 8387 8348 8308 8269 8229 8189 8150 8110 8070

-50 8031 7991 7951 7911 7872 7832 7792 7752 7712 7673

Resistance of 100 ohm RTD Degrees C

Insulation Resistance (IR) ~ Influence on the Resistance Measurement

IR refers to the electrical resistance between the sensing circuit and the metallic sheath of a RTD It is important for the sensing element circuit to be insulated from the sheath because electrical leakage can cause an error when measuring the

resistance of the sensing element Any error in measured resistance will translate to an error in the indicated temperature

For more information on Insulation Resistance please refer to The Burns Engineering Document ldquoError Sources That Effect Platinum Resistance Thermometer Accuracy Part 2 ndash Insulation Resistancerdquo (Available online at httpwwwburnsengineeringcomdocumentpdfa080211pdf)

(R )IR

(R )PRT

(R )MEASURED

RTD Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 43: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

42

R vs T degF

Resistance vs Temperature

0 1 2 3 4 5 6 7 8 9

400 17749 17769 17790 17810 17830 17851 17871 17892 17912 17932

390 17545 17565 17586 17606 17626 17647 17667 17688 17708 17729

380 17340 17361 17381 17402 17422 17443 17463 17483 17504 17524

370 17135 17156 17176 17197 17217 17238 17258 17279 17299 17320

360 16930 16951 16971 16992 17012 17033 17053 17074 17094 17115

350 16724 16745 16766 16786 16807 16827 16848 16868 16889 16909

340 16518 16539 16560 16580 16601 16621 16642 16663 16683 16704

330 16312 16333 16353 16374 16395 16415 16436 16457 16477 16498

320 16105 16126 16147 16167 16188 16209 16229 16250 16271 16291

310 15898 15919 15940 15961 15981 16002 16023 16043 16064 16085

300 15691 15712 15733 15753 15774 15795 15815 15836 15857 15878

290 15483 15504 15525 15546 15566 15587 15608 15629 15649 15670

280 15275 15296 15317 15338 15358 15379 15400 15421 15442 15462

270 15067 15088 15108 15129 15150 15171 15192 15213 15233 15254

260 14858 14879 14900 14921 14941 14962 14983 15004 15025 15046

250 14649 14670 14691 14711 14732 14753 14774 14795 14816 14837

240 14439 14460 14481 14502 14523 14544 14565 14586 14607 14628

230 14229 14250 14271 14292 14313 14334 14355 14376 14397 14418

220 14019 14040 14061 14082 14103 14124 14145 14166 14187 14208

210 13808 13829 13851 13872 13893 13914 13935 13956 13977 13998

200 13597 13619 13640 13661 13682 13703 13724 13745 13766 13787

190 13386 13407 13428 13450 13471 13492 13513 13534 13555 13576

180 13174 13196 13217 13238 13259 13280 13301 13323 13344 13365

170 12962 12984 13005 13026 13047 13068 13090 13111 13132 13153

160 12750 12771 12793 12814 12835 12856 12878 12899 12920 12941

150 12537 12559 12580 12601 12622 12644 12665 12686 12708 12729

140 12324 12346 12367 12388 12409 12431 12452 12473 12495 12516

130 12111 12132 12153 12175 12196 12218 12239 12260 12282 12303

120 11897 11918 11940 11961 11982 12004 12025 12047 12068 12089

110 11683 11704 11726 11747 11768 11790 11811 11833 11854 11876

100 11468 11490 11511 11533 11554 11576 11597 11618 11640 11661

90 11253 11275 11296 11318 11339 11361 11382 11404 11425 11447

80 11038 11060 11081 11103 11124 11146 11167 11189 11210 11232

70 10823 10844 10866 10887 10909 10930 10952 10973 10995 11017

60 10607 10628 10650 10671 10693 10715 10736 10758 10779 10801

50 10390 10412 10434 10455 10477 10498 10520 10542 10563 10585

40 10174 10195 10217 10239 10260 10282 10304 10325 10347 10369

30 9957 9978 10000 10022 10043 10065 10087 10109 10130 10152

20 9739 9761 9783 9804 9826 9848 9870 9891 9913 9935

10 9521 9543 9565 9587 9609 9630 9652 9674 9696 9717

0 9303 9325 9347 9369 9391 9412 9434 9456 9478 9500

0 -1 -2 -3 -4 -5 -6 -7 -8 -9

0 9303 9282 9260 9280 8216 9194 9172 9150 9129 9107

-10 9085 9063 9041 9019 8997 8975 8954 8932 8910 8888

-20 8866 8844 8822 8800 8778 8756 8734 8713 8691 8669

-30 8647 8625 9603 8561 8559 8537 8515 8493 8471 8449

-40 8427 8405 9383 8361 8339 8317 8295 8273 8251 8229

-50 8207 8185 8163 8141 8119 8097 8075 8053 8031 8009

-60 7986 7664 7942 7920 7898 7876 7854 7832 7810 7788

Resistance of 100 ohm RTD Degrees F

RTD Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 44: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Millivolts vs Temperature

mV vs T degC

43

Temp C T J E K

-50 -1819 -2663 -2787 -1889

-45 -1648 -2431 -2523 -1709

-40 -1475 -2197 -2255 -1527

-35 -1299 -1961 -1984 -1343

-30 -1121 -1722 -1709 -1156

-25 -0940 -1482 -1432 -0968

-20 -0757 -1239 -1152 -0778

-15 -0571 -0995 -0868 -0586

-10 -0383 -0749 -0582 -0392

-5 -0193 -0501 -0292 -0197

0 0000 -0251 0000 0000

5 0195 0000 0294 0198

10 0391 0253 0591 0397

15 0589 0507 0890 0597

20 0790 0762 1192 0798

25 0992 1019 1495 1000

30 1196 1277 1801 1203

35 1403 1537 2109 1407

40 1612 1797 2420 1612

45 1823 2059 2733 1817

50 2036 2322 3048 2023

55 2251 2585 3365 2230

60 2468 2850 3685 2436

65 2687 3116 4006 2644

70 2909 3382 4330 2851

75 3132 3650 4656 3059

80 3358 3918 4985 3267

85 3585 4187 5315 3474

90 3814 4456 5648 3682

95 4046 4726 5982 3889

100 4279 4997 6319 4096

105 4513 5269 6658 4303

110 4750 5541 6998 4509

115 4988 5814 7341 4715

120 5228 6087 7685 4920

125 5470 6360 8031 5124

130 5714 6634 8379 5328

135 5959 6909 8729 5532

140 6206 7184 9081 5735

145 6454 7459 9434 5937

150 6704 7734 9789 6138

155 6956 8010 10145 6339

160 7209 8286 10503 6540

165 7463 8562 10863 6741

170 7720 8839 11224 6941

175 7977 9115 11587 7140

180 8237 9392 11951 7340

185 8497 9669 12317 7540

190 8759 9947 12684 7739

195 9023 10224 13052 7939

200 9288 10501 13421 8138

mV in degrees C

The unique advantage of Thermocouples

Measuring the temperature of small objects or small amounts of fluid can be a big challenge While the RTD has the advantage over the thermocouple for sensor accuracy there are cases where the measurement accuracy may be better with the less accurate thermocouple For example measuring temperature of a fluid inside a 58rdquo diameter vial that has 116rdquo of fluid depth presents such a challenge It is very important to note the distinction between sensor accuracy and measurement accuracy for applications such as this because the two can be very different Details of the installation and ambient conditions are very important when selecting a temperature sensor for maximum accuracy

For more information on this topic please refer to the Burns Engineering Application Note ldquoA090826 RTD or

Thermocouplerdquo

Process Sheath Length

Process Sheath Length

RTD Element Sensitive Length

Thermocouple Junction Sensitive Length

Sensitive Length

Sensitive Length

Thermocouple Reference Table

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 45: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

mV vs T degF

Millivolts vs Temperature44

Temp F T J E K

-60 -1857 -2483 -2846 -1929

-55 -1762 -2353 -2699 -1830

-50 -1667 -2223 -2552 -1729

-45 -1572 -2092 -2404 -1628

-40 -1475 -1961 -2255 -1527

-35 -1378 -1828 -2105 -1425

-30 -1279 -1695 -1953 -1322

-25 -1181 -1562 -1801 -1218

-20 -1081 -1428 -1648 -1114

-15 -0980 -1293 -1494 -1010

-10 -0879 -1158 -1339 -0905

-5 -0777 -1022 -1183 -0799

0 -0675 -0886 -0868 -0586

5 -0571 -0749 -1026 -0692

10 -0467 -0611 -0550 -0370

15 -0362 -0473 -0709 -0478

20 -0256 -0334 -0227 -0153

25 -0150 -0195 -0389 -0262

30 -0043 -0056 0098 0066

35 0065 0084 -0065 -0044

40 0173 0225 0426 0286

45 0282 0365 0262 0176

50 0391 0507 0591 0397

55 0501 0649 0757 0508

60 0611 0791 0924 0619

65 0723 0933 1091 0731

70 0834 1076 1259 0843

75 0947 1220 1427 0955

80 1060 1364 1597 1068

85 1174 1508 1767 1181

90 1288 1652 1938 1294

95 1403 1797 2109 1407

100 1519 1942 2281 1521

105 1635 2088 2454 1635

110 1752 2234 2628 1749

115 1870 2380 2802 1863

120 1988 2527 2977 1977

125 2107 2673 3153 2092

130 2227 2821 3330 2207

135 2347 2968 3507 2321

140 2468 3116 3685 2436

145 2590 3264 3863 2552

150 2712 3412 4042 2667

155 2835 3560 4222 2782

160 2958 3709 4403 2897

165 3082 3858 4584 3013

170 3207 4007 4766 3128

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 5500 3590

195 3840 4757 5685 3705

200 3968 4907 5871 3820

205 4097 5058 6057 3935

210 4227 5209 6244 405

215 4357 536 6432 4165

220 4487 5511 662 428

225 4618 5662 6809 4395

230 475 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 757 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 834 5306

175 3333 4157 4948 3244

180 3459 4306 5131 3359

185 3585 4456 5315 3474

190 3712 4606 55 359

195 384 4757 5685 3705

200 3968 4907 5871 382

205 4097 5058 6057 3935

210 4227 5209 6244 4050

215 4357 5360 6432 4165

220 4487 5511 6620 4280

225 4618 5662 6809 4395

230 4750 5814 6998 4509

235 4882 5965 7188 4623

240 5015 6117 7379 4738

245 5148 6269 7570 4852

250 5282 6421 7762 4965

255 5416 6573 7954 5079

260 5551 6726 8147 5192

265 5687 6878 8340 5306

270 5823 7031 8535 5419

275 5959 7184 8729 5532

280 6096 7336 8924 5644

285 6233 7489 9120 5757

290 6371 7642 9316 5869

295 6510 7795 9513 5982

300 6648 7949 9710 6094

305 6788 8102 9907 6205

310 6928 8255 10106 6317

315 7068 8409 10304 6429

320 7209 8562 10503 6540

325 7350 8716 10703 6652

330 7492 8869 10903 6763

335 7634 9023 11104 6874

340 7777 9177 11305 6985

345 7920 9331 11506 7096

350 8064 9485 11708 7207

355 8208 9639 11911 7318

360 8352 9793 12113 7429

365 8497 9947 12317 7540

370 8643 10101 12520 7650

375 8789 10255 12724 7761

380 8935 10409 12929 7872

385 9082 10563 13134 7983

390 9229 10717 13339 8094

395 9377 10871 13545 8205

400 9525 11025 13751 8316

Temp F T J E K

mV in degrees F

Thermocouple Reference Table

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 46: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Temperature Measurement Expertsreg wwwburnsengineeringcom

Terminology and Options Guide45

Head amp Sensor Connection Options

Direct Immersion Sensors

Burns NET SolutionTM

shown with 38rdquo UNFheadsensor connections

Burns NET SolutionTM

shown with 12rdquo NPSMheadsensor connections

Burns Standard shown with 12rdquo NPT

headsensor connections

Conduit Connection

Head to SensorConnection

Process Connection

Sensor to Head Connection

Process Sheath Length

Wetted Surface

Burns Connection Heads are available with NPT NPSM and UNF threads See page 40 for more information

Direct Immersion sensors are available in several different diameters See pages 7 - 10 for more information

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 47: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

TO ORDER CALL 800-328-3871 FAX 952-935-8782 wwwburnsengineeringcom

Cable amp Strain Relief Options

Interconnect Style Sensors and Cable

Spring Loaded Style Sensors amp Thermowells

Process Connection

Extension Connection

Extension Connection

Sensor to Head Connection

lsquoCrsquo Compressed Sheath Length

Wetted Surface

Process Sheath Length

(15 inches)

lsquoLYrsquo Cable Length (120 inches std)

Shown as Quick Disconnect full assembly

Process Sheath LengthFor 3-wire single element sensors only

Cable Length

Strain Relief Option

A material and surface finish certification is supplied on all wetted surfaces See page 36 for other documentation available

Several different cable types strain relief and remote mounting options are available See pages 35 and 36

The Quick Disconnect is available with the S01 S03 S20 S40 SPA and SPS style sensors See the connection head ordering information for more details

Terminology and Options Guide46

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS

Page 48: Series S - Burns EngineeringBurns Engineering offers, as standard, the most common certifications required for sanitary applications. For all Series S sensors and thermowells that

Burns Engineering | 10201 Bren Rd E Minnetonka MN 55343 | email infoburnsengineeringcom

Phone (Toll Free) 800-328-3871 | Phone (Local) 952-935-4400 | Fax 952-935-8782 Copyright 2013 Burns Engineering IncPrinted in USA Bulletin 605 Rev 413

Burns Engineering is a leading supplier of

temperature measurement solutions for all your

process and metrology applications

Your processes require advanced temperature

measurement solutions that you can depend on We

understand that measurement accuracy reliability and

consistency are important to your success

Temperature measurement is our business

Burns Engineering has a long history of designing and building temperature sensors to meet the

measurement needs of unique and varied applications The products in this catalog were specifically

developed to meet field requirements and allow for configured-to-order flexibility Not sure what product

is right for your application Our application engineering group is here to help you select configure

andor custom design the right product for your specific needs

Custom solutions designed for your specific needs

What will your solution BE

Turn to Burns as your

Temperature Measurement Expertreg

Trademarks contained in this catalogBurns Engineering Logo Temperature Measurement Experts NET Solution and RTDology are trademarks of Burns EngineeringIngold is a registered trademark of Mettler-Toledo 3-A is a trademark of 3-A Sanitary Standards Inc Chromel and Alumel are registered trademarks of Hoskins Mfg Company Teflon is a registered trademarks of EI du Pont Nemours and Company Intertex is a registered trademark of Intertech Inc

SANITARY SENSORS