1176570-2A-D 1
BEFORE YOU BEGIN
All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.
Please leave these instructions for the consumer. They contain important information.
NOTES:1. Flush the water supply pipes throughly to remove debris.2. Observe local plumbing codes.3. Inspect the supply pipes for damage and leakage. Replace and maintain as necessary4. The minimum inlet water pressure for the diverter is 0.05MPa(0.5bar).5. The highest working pressure for handshower is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a pressure reducer is needed. The highest water and environment temperature is 60°C. Please keep shower head, handshower and shower arm away from heater, or it may become damaged and cause injury to the user.
45370K-4E2 WALL MOUNT BATH SHOWER FAUCET
INSTALLATION INSTRUCTIONS Wall Mount Bath Shower Faucet
45370K-4E2 WALL MOUNT BATH SHOWER FAUCET
Wall Mount Bath Shower Faucet
HANDLE OPERATION
ROUGH-IN DIMENSIONS
Lift the handle gently, turn clockwise for hot water, turn counter-clockwise for cold water, bath spout works; turn bath spout clockwise or counter-clockwise, shower works.
STRAYTSTRAYT
1176570-2A-D 4
SERVICE PARTS
**Color code must be specified when ordering
3010697**Nut
3010698O-ring
871363O-ring
864985Seat
1218659Washer
1161905**Escutcheon
1170944**Connector
1167323**Bonnet
834792Nut
833438Screw
1106842**Plug Button
1160487**Handle
834793Valve
880086O-ring
1120988Anchor1177385**
Mounting Bracket
1119427Screw
1177515Washer1177513**
Bracket Kit
833730Hex Wrench
1248781**Hose
1297484**Handshower
1088901Regulator 77420
Washer
1240266Check Valve
1285735Washer
42084O-ring
1024329O-ring
91640O-ring
32725O-ring
3005148Aerator
3006148Key
1276812Diverter
1285734**Connector
Hose
Bracket
210
60X
60
G1/2˝
82~92G1/2˝
239~249
179
85
Handshower
G1/2˝
G1/2˝
1500
Finished Wall
56 36
5636
36
81
35°35°
150±
15
90º
90º
G1/2˝
250
28 28
240
1176570-2A-D 2
1176570-2A-D 3
INSTALLATION
How to Install the Faucet
To perform installation, installer must provide G1/2″ female supply fittings (1), spaced 150mm apart and level. The supply fittings should be vertical and not beyond the finished wall. Hot supply pipe must be located on the left.
Install the two offset connectors(2) into the hot and cold supply pipes. Use appropriate thread sealants or thread tape on pipe threads.
Adjust the center-to-center distance between the connectors to 150mm and horizontal. They should extend 36 to 47mm beyond the finished wall.
Slide the escutcheons(3) onto the nuts(4). Put the washers(5) into the nuts, thread the nuts to connectors. Tighten the nuts with strap wrench or soft cloth between product and regular wrench. Push the escutcheon against the finished wall.
Remove the guards on the outlet connectors of the hose(6). Tighten one connector(7) of the hose to the connector(8). Install the regulator(11) into the handshower(10) inlet if needed. Tighten the other connector(9) of the hose to the handshower.
150mm
36~47mm
2
1
Hot
Cold
How to Install the Bracket
Determine a suitable location on the finished wall to install the bracket.
Mark bracket support(12) mounting hole locations on the wall according to the dimension. Drill two holes on the finished wall, the holes should match the anchors(13). Install the anchors. Tighten screws(14) to secure bracket support.
Before installing the bracket(15), check if the ring(16) of the bracket loosen. If yes, tighten the nut(17) on the bottom of the bracket with 9.5mm hex wrench(not provided). Install the washer(18) onto the bottom of the bracket, and then tighten the bracket onto the bracket support until they contact the finished wall.
12
15
13
14
16
17
18
34
5
6
7
8
9
10
11
INSTALLATION CHECKOUT
Ensure that all connections are tightened. Ensure that the handle is in the off position.
Turn on the drain and main water supply, and check for leaks. Repair as needed.
Remove the handshower(10). Remove the aerator(20) with the key(19). Turn on the faucet. Run the water through the spout for about one minute to remove any debris. Check for leaks. Remove any debris from the aerator. Shut off the faucet. Reinstall the handshower and aerator.
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
20
10
19
How to Operate the Handshower
Press the buttons of the handshower to change the water flow.
Katalyst Air
Intense Massage
How to Maintain the Handshower
Any debris or mineral build-up may cause the flow stream to become distorted or reduce the flow rate. To remove the debris or mineral build-up, run water through the handshower, firmly press or rub your finger back and forth across the rubber nozzles.
Remove and clean the screen washer.