S
TT
2
T
SAHU-1
12
CU 015
T
AHU 014 8
10
1EF 01
6
R-1 1500(TYP FOR 2)
16"Ø
GV 019
GV 019
CU 025
7
R-1 1000(TYP FOR 2)
14"Ø
SAHU-2
12
AHU 02 4 810
PTAC 0113
M1.0SCHEDULE
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
PLOT DATE:
PIZZA HUT
401 2nd St.Soperton, GA
XX.XX.XX
09.01.11
308145
403833
02.17.12
DESCRIPTION DATE
DELCO LITE
DELCO LITE
DESCRIPTION
CEILING DIFFUSER/SUPPLY REGISTER
EXHAUST AIR DUCT (RISE/DROP)
RETURN AIR DUCT (RISE/DROP)
SINGLE LINE DUCT BRANCH TAKE-OFF
DOOR UNDERCUT (3/4" MINIMUM)
FLEXIBLE DUCT (5'-0 MAXIMUM)
DUCT TRANSITION (RECTANGULAR TO ROUND)
DUCT LINING (1" THICK UNLESS OTHERWISE NOTED)
RECTANGULAR DUCT ELBOW WITH TURNING VANES
(ARROWHEAD REPRESENTS NUMBER OF THROW)
FURNISHED AND INSTALLED BY MECHANICAL
INSTALLED BY ELECTRICAL CONTRACTOR.FURNISHED BY MECHANICAL CONTRACTOR AND
FURNISHED AND INSTALLED BY ELECTRICAL
RR/RG RETURN REGISTER/GRILLE
CONTRACTOR.
DIAMETER
CONTRACTOR.
DOOR LOUVER
CONDENSATE DRAIN
DIA.
UC
DL
T-STAT
D
FLEX
EXHAUST REGISTER/GRILLE
FIRE DAMPER
MANUAL VOLUME DAMPER
FLEXIBLE CONNECTION
MVD
(L)
FD
FC
ER/EG
SUPPLY AIR (RISE/DROP)
CD/SR
RA/RET
EA/EXH
SA/SUP
SYMBOL & ABBREV.
T-STAT
PROGRAMMABLE THERMOSTAT
STA
RTE
R
ELECT.
MATERIAL
ALU
M.
PLA
STI
C
PRESSUREEASAOA RAITEM
875
--
-875---- --EF-1
AHU-1
TOTAL
MANUFACT. MODEL NO. REMARKS
DUTY
SU
RFA
CE
SU
PP
LY
RE
TUR
N
EXH
AU
ST
CFM RANGE
LAY-
IN
MOUNTINGTYPE
DIF
FUS
ER
RE
GIS
TER
GR
ILLE
ORNECKSIZE
CEILING GRID
DIFFUSER FACE
SIZE (INCHES)
(NO.) & AIRPATTERN
QU
AN
TITY
MARK
REMARKSAND
MODEL NO.D-D
R
ACCESSORIES
BIR
DS
CR
EE
N
V-B
ELT
BD
D
DIS
C
HPRPMSPCFM
MARK
MANUFACTURER
(WATTS)
FOR COMPLETE INFORMATION AND PRICING ON THE TRANE HVACPACKAGE CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNTEXECUTIVE AT TRANE NATIONAL ACCOUNTS.TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986-4822FAX: (502) 499-7870EMAIL: [email protected]
THERMOSTAT SENSOR (REMOTE)
XX-XXXXX-XXX
AIR BALANCE SCHEDULE CFM 6
AIR DEVICE SCHEDULE 5
MECHANICAL SYMBOLS 9
SUPPLY AND EXHAUST FAN SCHEDULE 2
HVAC UNIT SCHEDULE 4
T
TS
M
E
ME
DL
UC
Ø
D
750 3000 +750
9451250 5000 +305
GENERAL NOTES:1. THE PIZZA OVEN HOOD IS ACTIVATED USING A TEMPERATURE RELAY, SET TO 90 DEGREES.2. RESTROOM FAN IS ACTIVATED WITH LIGHT SWITCH, IN RESTROOM.
LEVEL SUPPORT BY THE G.C. REFER TO DETAIL 5/P4.0.FABRICATED PLATFORM ON THE ROOF. ROOF PENETRATIONS ANDCONDENSING UNITS TO COOLER/FREEZER MOUNTED ON FEILD
DO NOT ROUTE ANY DUCTWORK OVER ELECTRICAL PANELS.
1
5
7
8
6
9
MECHANICAL PLAN 1/4"=1'-0" 1
KEY NOTES 3
GASKET
TRANSITION TO ROUNDSEE PLANS FOR SIZE
BUTTERFLY DAMPER WITHARM & LOCKING QUADRANT(TYPICAL)
SHORT RADIUS RIGIDMETAL ELBOW WHERE1.5D FLEX ELBOWCANT BE MAINTAINED
1 1/2" DUCT WRAPINSULATION
FLEX DUCT SEESPECIFICATIONS FORMAX. ALLOWABLELENGTH (TYPICAL)
STRAP HANGER
LOW VELOCITYDUCT
NYLON STRAPFASTENER (TYP)
45° ENTRYCLINCHED COLLAR
1.5DMIN
SUPPLY
MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT RUNOUTS TOSUPPLY DIFFUSERS = 5'-0". FLEX DUCT IS NOT ALLOWEDON EXHAUST, RETURN, AND EXPOSED DUCTWORK.
DIFFUSER INSTALLATION DETAIL N.T.S. 7
GENERAL NOTES 8
SPECIFICATIONS.SHUTDOWN FOR AHU-1 & AHU-2. REFER TO ELECTRICAL DRAWINGS ANDINSTALL SMOKE DUCT DETECTOR IN SUPPLY DUCTWORK AND UNIT
THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND SUPPORT OFROOFTOP EQUIPMENT WITH BUILDING STRUCTURE AND CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ROOFTOP UNITS TO ALLOW DUCT CONNECTION AND ROUTING AS SHOWN PER PLANS.
ANY FRESH AIR INTAKE SHALL BE SEPARATED FROM BUILDING EXHAUST, FLUES, OR PLUMBING VENTS AS REQUIRED BY LOCAL CODES.INSTALLATION OF APPROVED ROOFTOP UNITS OTHER THAN TRANE MAY REQUIRE MODIFICATIONS TO DUCTWORK LAYOUT. VERIFY ALL REQUIRED CLEARANCES FOR OTHER MANUFACTURERS.
THE CONTRACTOR SHALL VERIFY ALL STRUCTURAL CONDITIONS FORCEILING SPACE AND EXACT DUCT ROUTE PRIOR TO FABRICATION. VERIFY IN FIELD EXACT ROUTING OF DUCTWORK TO ALLOW PROPER LOCATION OF LIGHTS AS SHOWN.
1.
2.
3.
5.
4.
6.
THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS SHEETS FOR FURTHER INFORMATION.
--
--
XEGER ADVANTAGE SQ. TO RD. TRANS.XX 300-500X12x12 24x24 PRODUCTS
PLASTIC DIFFUSERSS-1 (6) 3W, (4) 4W
NA120V14000.25"70EF-2 ACCUSERV #05247-017(100w) X XX
---- --EF-2 70 -70---- --
XXR-1 20x20 24x24 (4)4WC1000-1500
X X XEGER
PRODUCTS
X
2
TOTAL NET
1
LBS
REMARKS
OP
ER
. WT.
MO
CP
MC
A
PH
AS
E
VOLT
S
FAN
HPCAPACITY
HEATING
MBH
MODEL #
COMPRESSOR SECTION
MBHCAPACITYCOOLING
(SE
ER
)M
IN. E
ERDRIVECFM ESPAND
MANUFACTURER
MODEL NO.MARK
AHU-1
INPUT
15kwTRANE
.80"3000 BELT 11.2 - BAYHTRL315A 1 208 3 50 60 323
XX-XXX
BTU
H/W
ATT
S
TWE090D3
EVAP. EAT DB/WBAMB.
COOLING
SENS.ANDMANUFACTURER
MODEL NO.MARK
CU-1
VOLT/Ø/HZ
TRANE 8394 100 80/67 208/3/60
XX-XXX
TTA090E3
TOTAL
MBH BTUH
ELECTRICAL
MCA
31.1
--AHU-2 500 2000 +500--
9" X 9" WELDED EXHAUST DUCT FROM OVEN HOOD UP THRU ROOF ANDTRANSITION TO EF-1 AS SHOWN. DUCT SHALL BE WRAPPED IN ACCORDANCEWITH JURISDICTION HAVING AUTHORITY.
2
4 NEW AIR HANDLING UNIT. VERIFY EXACT LOCATION AND CLEARANCEAVAILABILITY IN THE FIELD. INSTALL COMPLETE WITH FIELD FABRICATED DRAINPAN WITH FLOAT KILL SWITCH, FIELD FABRICATED RETURN AIR PLENUM BOX,AND ELECTRIC HEATER AS SPECIFIED. INSTALL TIGHT TO STRUCTURE.
6'-0" x 8'=0" OVEN HOOD. SEE M2.0.
ROUTE 14"Ø OUTSIDE AIR DUCT FROM GV-1 (GREENHECK MODEL #GRSI15)TO FIELD FABRICATED RETURN AIR DUCT PLENUM BOX AT AIR HANDLINGUNITS AS SHOWN. INSTALL COMPLETE WITH BACKDRAFT DAMPER AT GRAVITYVENTILATOR.RUN REFRIGERANT LINES FROM CU-X TO AHU-X. SIZED PER
MANUFACTURER'S RECOMMENDATION. VERIFY LINE PLACEMENT ANDROUTING WITH EXISTING FIELD CONDITIONS.
ROUTE SUPPLY AND RETURN DUCTWORK SIZED AS SHOWN FROM THE AHUCONNECTIONS TIGHT TO THE BOTTOM OF THE STRUCTURE. PROVIDEFLEXIBLE CONNECTIONS AND TRANSITION AS REQUIRED.
ROUTE 1" CONDENSATE PIPING FROM AHU TO NEAREST AVAILABLEAPPROVED RECEPTOR AND TERMINATE WITH INDIRECT DISCHARGE. PITCHCONDENSATE PIPING A MINIMUM 1/4" PER FOOT IN THE DIRECTION OF FLOW.
10
ROOF AND TERMINATE PER MANUFACTURER'S INSTRUCTION.ROUTE 3"PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE UP THRU11
AHU-2 15kwTRANE
.80"2000 BELT 13.0 -TWE061D3 1 208 3 49 50 1232
REMARKSMOCP
CU-2TRANE
TTA073E3 5674 100 80/67 208/3/60
34.4
40
45 1 / 2 / 3
1 / 2 / 3
WIRED BACK TO RESPECTIVE THERMOSTAT AT MANAGER'S DESK.REMOTE ZONE TEMPERATURE SENSOR INSTALLED @ 54" A.F.F.12
PROVIDE WOVEN FILTER.
3
BAYHTRL315A
REFER TO DETAIL 07/P3.0.
AIR DEVICE(S) SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED INSULATION BACKING IS NOT ALLOWED
BY E.C.115/1Ø X CAPTIVEAIRE #DU50HFAX1/215651.50"875EF-1 1
VENSTAR 2900 THERMOSTAT MOUNTED ON WALL AT 48" A.F.F. NEARMANAGER'S DESK.
CONDITIONING UNIT (208/1/60 - MOCP=20). PROVIDE WITH LEVELING LEGS,LG MODEL #LP153HD3A FLOOR MOUNTED PACKAGED TERMINAL AIR13
WALL SLEEVE, AND WIRELESS WALL THERMOSTAT.
MASTER DRAWING
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
PLOT DATE:
PIZZA HUT
401 2nd St.Soperton, GA
XX.XX.XX
09.01.11
308145
403833
02.17.12
DESCRIPTION DATE
DELCO LITE
DELCO LITE
M2.0
PIZZA HOOD& EXHAUST
FAN DETAILS
P1.0
PLUMBINGSCHEDULE &
NOTES
ABBREVIATIONS
PRESS-TEMPERATURE RELIEF VALVE
PREMIXED TEMPERATURE WATER
FLOOR CLEANOUT OR CLEANOUT TO GRADE
C.D.
F.C.O.
FW
W.C.O.
S.O.V.
H.B.
C.V.
S.O.C.
P.T.R.V.
B.V.
TWTW
FW
CD
CHECK VALVE
BALL VALVE
SHUT-OFF GATE VALVE
SHUT-OFF GAS COCK
FILTERED WATER
WALL CLEANOUT
CONDENSATE DRAIN
HOSE BIBB
ABBREV
S OR W
CW
H.W.R.
HW
S.D.
SYMBOLS
SD
V.
G G
DESCRIPTION
SOIL OR WASTE
COLD WATER
STORM DRAIN
SANITARY VENT
HOT WATER RETURN
HOT WATER
GAS
COLD WATER BELOW GRADE
FILTERED TEMPERED WATER
FLOOR DRAIN
FLOOR SINK
HUB DRAIN
F.S.
F.D.
H.D.
FTW FTW
C.W.
ABOVE FINISHED FLOOR
EXTERIOR CLEAN OUT
CAST IRON
OVERFLOW DRAIN
EXISTING
GAS LINE
NEW
YARD BOX
ROOF DRAIN
VENT THRU ROOF
ACCESS PANEL
VENT BELOW FLOOR
UP THRU ROOF
A.F.F.
E.C.O.
C.I.
G.L.
OFD
(E)
(N)
A.P.
V.B.F.
U.T.R.
V.T.R.
R.D.
Y.B.
S.O.V. SHUT-OFF IN DROP
YARD HYDRANTY.H.
B.F.P. BACKFLOW PREVENTER ASSEMBLY
GREASE WASTEGWGW
UNION
SS
CONDENSATE DRAIN WITH 120V HEAT TAPECD C.D.
TEMPERING MIXING VALVE
CW
HW
HWR
PLUMBING SCHEDULE A
PLUMBING LEGEND B
SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE.
ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED INPLACE.
CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISETHE SEWER SYSTEM AS REQUIRED.
PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODE. PROVIDE DEEPSEAL TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS.
ALL CLEANOUTS SHALL BE INSTALLED SO THAT THEY ARE READILY ACCESSIBLE. THE CONTRACTOR SHALLCOORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION.
ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS AND OTHER EQUIPMENT SHOWN IN WALLS ORABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACEAND 10 FEET FROM ANY OUTSIDE AIR INTAKE.
CONTRACTOR SHALL PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED.
PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OFEQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODEAND RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECEOF EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THEGAS METER.
ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS.
REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORKTO BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TOKITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR.
REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS.
ALL GAS LINES SHALL BE SUPPORTED.
ALL FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE.
PROVIDE WATER HAMMER ARRESTORS FOR ALL WATER LINES.
PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THEDIAMETER OF THE INDIRECT DRAIN.
PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION ANDCONDITION OF ALL EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATEDWHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY.
CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TOAVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS.
CONTRACTOR SHALL FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIESHAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0"A.F.F.
CONTRACTOR SHALL PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TOUNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION.
THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITHTHE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N.
IT IS THE G.C.'S RESPONSIBILITY TO CONFIRM THE AVAILABLE "RESIDUAL" WATER PRESSURE, PRIOR TO THESTART OF ANY WORK, AND NOTIFY THE OWNER IF THE AVAILABLE PRESSURE IS NOT ADEQUATE TO SERVICETHE ANSUL SYSTEM OR OTHER PRESSURE SENSITIVE EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND & SHALL NOT REQUIRE TIGHTGRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BEMOUNTED NO MORE THAN 44" ABOVE THE FLOOR, THE FORCE REQUIRED TO ACTIVATE CONTROLSSHALL BE NO GREATER THAN 5 POUNDS.
A CLEAR FLOOR SPACE 30" WIDE BY 48" LONG SHALL BE PROVIDED IN FRONT OF THE LAVATORY TOALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP ANACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE & TOE SPACE UNDERNEATH THE LAVATORY.
HOT WATER & DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACE UNDER LAVATORIES.
FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND & SHALLNOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TOACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS/FT LEVER PUSH-TYPE &ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN, SELFCLOSING VALVES ARE ALLOWED IF THE FAUCETS REMAIN OPEN FOR AT LEAST 10 SECONDS.
FLUSH HANDLES SHALL BE ON THE WIDE SIDE OF STALLS IN DISABLED ACCESSIBLE STALLS.
MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE NOT MORE THAN 40" FROM THE FLOOR.
LOCATE HAND DRYER OPERABLE PARTS NOT MORE THAN 40" FROM THE FLOOR.
LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12" OF THE FRONT EDGE OF THE TOILETSEAT.
ACCESSIBILITY NOTES D
GENERAL NOTES C
FS 1 FLOOR SINK 4" 2" -- -- -- 6 --PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP 1/4" ABOVE FLOOR TILE.
JOSAM / MODEL: JPFS4-PVC
JONESPEC / MODEL: FD-2370-PV4-DS-F
FD 1 FLOOR DRAIN(3")
3" 2" -- -- -- 2 --PVC FLOOR DRAIN, 5" DIA.IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USEDFOR THE FIRST 10'-0" FROM THE DRAIN
ZURN / MODEL: FD-2212-ST
ECO 1EXTERIORCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WC 1WATERCLOSET 4" 2" 1/2" -- -- 4 2 CRANE "ECONMISER" / MODEL: 3H839
SA 1SHOCKARRESTOR -- -- 1/2" -- -- -- --
STAINLESS STEEL CASING WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN.SIZED PER PDI-WH201
WADE / SHOKSTOP
JOSAM / MODEL: 75000
ZURN / SHOKTROL
MV 1MIXINGVALVE -- -- 1/2" 1/2" -- -- --
THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER,CHECK VALVES SIZE PER PIPE CONNECTIONS.
HYDROTEK SERIES HBL
LAWLER SERIES 61
LEONARD SERIES 210
S 33-COMP.SINK INDIRECT -- 3/4" 3/4" -- -- 3
STAINLESS STEEL 3 COMPARTMENT SINK, FAUCET & DRAINFURNISHED BY OWNER, INSTALLED BY CONTRACTOR.
AERO # 3F3-DC-YUM-RH48
--
--
S 1 HAND SINK 1-1/2" 1-1/2" -- -- 1/2" 2 1.5STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS.FAUCET W/KNEE PEDAL VALVE. OWNER FURNISHED AND CONTRACTOR INSTALLED. CONTRACTOR TO PROVIDE STAINLESS STEEL SPLASH GUARDS, AS REQUIRED.
AERO # HSK
ALL STRONG, MODEL #HS-1516KSS
SANILAV, MODEL #CLS-505
HD 1 HUB DRAIN 3" 2" -- -- -- 2 --CAST IRON DEEP SEAL P-TRAP WITH FUNNEL, NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG.
JOSAM / MODEL: 88213
WADE / MODEL: 2453EF
ZURN / MODEL: Z-1019
WCO 1WALLCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS PLUG, WITH STAINLESS STEEL ACCESS COVER.
JOSAM / MODEL: 58510
WADE / MODEL: 8560E
ZURN / MODEL: Z-1446-BP
FCO 1FLOORCLEANOUT -- -- -- -- -- -- --
CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER.
JOSAM / MODEL: 56000
WADE / MODEL: 6000Z
ZURN / MODEL: Z-1400
WH 1WATERHEATER -- -- 3/4" 3/4" -- -- --
GAS FIRED WATER HEATER, 84% THERMAL EFF., 199,000 BTUH INPUT, INSTANTANEOUS TYPEHEATER, 9.8 GPM @ 35°F RISE, UBBINK CONCENTRIC FLUE/AIR INTAKE SYSTEM (WALL-TYPE),DIRECT ELECTRONIC IGNITION SYSTEM, REMOTE ELECTRONIC CONTROLS AND INTEGRALDIAGNOSTICS. SEE NATIONAL PRICING CONTACT BELOW.
RINNAI / RC94LSi--
--
VENTSOIL ORWASTE
FIXTUREITEM
WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE,ELONGATED BOWL, ADA COMPLIANT, 1.6 GPF, WITH OPEN FRONT SEAT LESS COVER,OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLLUSHMATE OR EQUAL.PROVIDE TANK COVER LOCKS. FLUSH VALVES SHALL BE RIGHT HAND OR LEFT HAND ASREQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDEREQUIREMENTS
WATERFU
WASTEFU
TEMP'DWATER
HOTWATER
COLDWATER
DESCRIPTION MANUFACTURER / MODEL NUMBER
L 1 LAVATORY 1-1/2" 1-1/2" -- -- 1/2" 1 1.5WHITE VITREOUS CHINA, WALL HUNG, WITH WALL HANGAR SUPPORT, 4" CENTERS,WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHEDBY OWNER-INSTALLED BY G.C. SINGLE LEVER TYPE FAUCET, ADA COMPLIANT.CONTRACTOR TO PROVIDE PROPER WALL MOUNTING SUPPORT.
A.S. COMRADE/ MODEL: 0124.024
CRANE "HARWICH" / MODEL: 1412V
S 2 MOP SINK 3" 2" 1/2" 1/2" -- 3 2.25MOP SINK: 24"L X 24" W X 10" H. FIBERGLASS.OWNER FURNISHED AND CONTRACTOR INSTALLED.FAUCET: T & S #B-0674-BSTP, WITH VACUUM BREAKER, FURNISHED BY OWNER-INSTALLED BY G.C.
E. L. MUSTEE & SONS, MODEL # 63M
--
--
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
WATER HEATER NATIONAL ACCOUNT PROCESS:RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:
RINNAI COMMERCIAL NATIONAL ACCOUNT PROCESS:
1) CNA contacts Rinnai Inside Sales at 1.866.383.0707.
2) Rinnai will provide CNA with distributor contact in the project market to facilitate ordering.
3) CNA, General Contractor or installer will contact distributor and purchase product.
1) CNA contacts Rinnai at 1.866.383.0707 and follows prompts to Service.
2) Rinnai will provide CNA with Authorized Service Providers (ASP) in the area of the facility.
3) CNA will contact the ASP to maintain or service the product.
GI 1GREASEINTERCEPTOR 4" 3" -- -- -- -- --
GREASE INTERCEPTOR SHALL BE A SCHIER POLYETHYLENE INTERIOR GREASE TRAP. INSTALLCOMPLETE WITH RIGID COVER SUITABLE FOR HEAVY FOOT TRAFFIC. MAX FLOW RATE = 100GPM. LIQUID CAPACITY = 125 GALLONS. GREASE CAPACITY = 450 LBS.
SCHIER #GB-125
--
--
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
PLOT DATE:
PIZZA HUT
401 2nd St.Soperton, GA
XX.XX.XX
09.01.11
308145
403833
02.17.12
DESCRIPTION DATE
DELCO LITE
DELCO LITE
S 41-COMP.SINK INDIRECT -- 1/2" 1/2" -- -- 3
STAINLESS STEEL 1 COMPARTMENT SINK, FAUCET & DRAINFURNISHED BY OWNER, INSTALLED BY CONTRACTOR.
AERO # MF1-2116-18R
--
--
S
TT
E3.0
LIGHTING &
PLAN
KEYED NOTES 2
LIGHTING PLAN 1/4"=1'-0" 1
COMMUNICATIONS AND SECURITY PLAN 2
K
A
NO. LOCATION MANUFACTURER / ITEM NUMBER FIXTURE TYPE / BALLAST
ACRYLIC LENS
SUPPLIED W/ FIXTURE
F32T8 LAY-IN GRID
MOUNTING VOLTAGE WATTAGE REMARKS
KITCHEN 120 96
BACKPLATE / WALL EXIT FIXTURE WITH EMERGENCY BATTERY. SEE LIGHT FIXTURE SCHEDULE NOTE #2.3
LIGHTOLIER / XP2GVA232120SO
LITHONIA / LHQM S W 3 R
2' X 4' TROFFER / ELECTRONIC
LED EXIT / FLOOD LIGHTS
3
- 120KITCHEN/ENTRY
(ALL FIXTURES AND LAMPS SUPPLIED BY OWNER)
TYPE#LAMPS
(ALL FIXTURES INSTALLED BY CONTRACTOR)
A2 KITCHEN THOMAS / CM6 / FV26 / V65B / BH3 2' X 4' TROFFER / ELECTRONIC 3
QUANT
6
3
4
J SUPPLIED W/ FIXTURE TRACK 50LIGHTOLIER / 6004WH TRACK HEADS - 120ENTRY2
JB N/A CEILING N/ALIGHTOLIER / 9023WH 4' TRACK - N/AENTRY1
ACRYLIC LENSF32T8 LAY-IN GRID 120 96
CONTRACT DATE:
BUILDING TYPE:
PLAN VERSION:
SITE NUMBER:
STORE NUMBER:
PLOT DATE:
PIZZA HUT
401 2nd St.Soperton, GA
XX.XX.XX
09.01.11
308145
403833
02.17.12
DESCRIPTION DATE
DELCO LITE
DELCO LITE
10
9
7
6
5
4
3
2
1
8
INSTALL ALL EMERGENCY AND EXIT LIGHTING ON UNSWITCHED LEG OF LIGHTING CIRCUIT.
EXHAUST HOOD LIGHTS SUPPLIED WITH HOOD AND MTD IN PRE-WIRED J-BOX. COMPLETE CIRCUITINGPER DETAIL 8/E1.0.
NOT USED.
J-BOX FOR ILLUMINATED SIGN. VERIFY ELECTRICAL REQUIREMENTS AND EXACT LOCATIONS FOR J-BOXWITH ARCHITECTURAL ELEVATIONS AND SIGN VENDOR.
CONTROLLED BY EXTERIOR SIGNAGE CONTACTOR. REFER TO EXTERIOR SIGNAGE CONTROL DIAGRAMON SHEET E1.0.
LIGHTING FIXTURES & SWITCHES FOR COOLER/FREEZER ARE PROVIDED WITH COOLER/FREEZER.FIXTURES & SWITCHES ARE TO BE INSTALLED BY ELECTRICAL CONTRACTOR PER MANUFACTURESREQUIREMENTS AND N.E.C. ARTICLE 300-7. CONTRACTOR TO PROVIDE 100W A19 LAMPS FOR COOLERAND FREEZER FIXTURES.
ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL WIRING INSIDE COOLER/FREEZER PERMANUFACTURERS REQUIREMENTS AND N.E.C. ARTICLE 300-7 (1999). ALL CONDUITS ENTERING ORLEAVING COOLER/FREEZER SHALL BE PROVIDED WITH SEAL-OFF FITTINGS WITH COMPOUND PERN.E.C. 300-(7A)(1999).
NOT USED.
ROUTE CIRCUIT THROUGH LIGHTING SWITCH. SEE DRAWING SHEET E1.0 FOR CONTROLS.
PROVIDE 120V ,1P/20 AMP WALL SWITCH AT 48" AFF BEHIND CUSTOMER COUNTER FRONT OF HOUSELIGHTING AND EXTERIOR SIGNAGE LIGHTING. SEE DRAWING SHEET E1.0 FOR CONTROLS.LABEL SWITCHES.
GENERAL NOTE:HORIZONTAL DIMENSIONS TO DATA PULL J-BOXES ARE FROM FACE OF STUD CENTER OF BOX, U.O.N.THE VERTICAL DIMENSION OF 24" IS FROM FINISH FLOOR TO CENTER OF J-BOX, U.O.N.
HOLD UP BUTTON CENTERED ABOVE DOOR. MOUNT AT TOP OF JAMB WITH CONDUIT STUBBED UPABOVE CEILING.
HOLD UP BUTTON LOCATION (MOUNT 2 1/2" BEHIND COUNTER EDGE). VERIFY AND REQUIREMENTSWITH SECURITY PROVIDER.
ALARM KEYPAD
HOLD UP BUTTON BY MANAGER DESK. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SECURITYPROVIDER.
TELEPHONE COMPANY DEMARK BOARD - PROVIDE (1) 2" CONDUIT WITH PULL STRING FROMTELEPHONE TERMINAL BOARD TO TELEPHONE SERVICE ENTRANCE. PROVIDE SWEEPING 90° ELBOWSAT ALL TURNS. VERIFY SITE AND TELEPHONE COMPANY REQUIREMENTS PRIOR TO BIDDING. SEEARCHITECTURAL ELEVATION DETAIL FOR SIZE AND MOUNTING.
PROVIDE (1) 2" CONDUIT WITH PULL STRING STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM J-BOXAT COMPUTER WALL CABINET FOR DATA CABLES. PROVIDE SWEEPING 90° ELBOWS AT TURNS.
PROVIDE (1) PULL STRING STUBBED UP ABOVE TO ACCESSIBLE CEILING FROM EACH VOICE,VOICE/DATA AND DATA OUTLET. PROVIDE SWEEPING 90° ELBOWS AT ALL TURNS.
TELEPHONE TERMINAL BOARD FOR PIZZA HUT TELEPHONE SYSTEM LOCATION. SEE ARCHITECTURALELEVATION DETAIL FOR SIZE AND MOUNTING.
OVERHEAD TELEPHONE BELL PROVIDED BY PHONE INSTALLER.
PROVIDE (1) QUAD BOX FOR ALL LOW VOLTAGE LINES CENTERED UNDERCOUNTER.
PROVIDE (1) 3/4" CONDUIT WITH PULL STRING FOR CAT5 DSL FROM DEMARK TO THE OFFICE.
1
6
5
4
3
2
LIGHTING NATIONAL ACCOUNT:ACCUSERV LIGHTING:
PRIMARY CONTACT: ASHLEY GARNERPHONE: (877) 707-7378FAX: (502) 961-0357EMAIL: [email protected]
ACCUSERV HAS AGREED TO PROVIDE A PHOTOMETRICS STUDIES FOR ALL DELCOS.ONCE AN EQUIPMENT PLAN IS COMPLETE, EMAIL THE AS-BUILT AND BASE PLANS TOACCUSERV FOR PHOTOMETRIC. EACH SPACE WILL BE DESIGNED FOR A MIN. OF 50 FOOTCANDLES THROUGH OUT THE SPACE. ACCUSERV HAS AGREED TO RETURN THE PHOTOMETRIC WITH LIGHTING LAYOUT WITHIN 48 HOURS.
WP
A-29
A-36
P
J4
P
51
10
7
9
1
7
6
9
AA2
1
S1
S2
76"
5
116"
S4
4
1
S176"
(TYP.)
J
USE AS STARTING POINTFOR DIMENSION OF OUTLETS
6
PANEL 'A'
24"
USE AS STARTING POINTFOR DIMENSION OF OUTLETS
2
3
3
3
7
7
6
A2
A2
AAA
A
A
1
1
6
6
COMPUTERPATCH PANEL
S3
B ACRYLIC LENS2F96T12HO CHAIN MOUNT 120 60LIGHTOLIER / KD4S248120HI ELECTRONIC BALLAST 25BACKROOM /
CORRIDOR
B
BE B
BE
B
B
B
120BE ACRYLIC LENS WITH BATTERY BACKUP FOR 90 MINUTES.2F96T12HO CHAIN MOUNT 60LIGHTOLIER / KD4S248120HI/EM ELECTRONIC BALLAST 22BACKROOM /
CORRIDOR
1
1
1
1
FOR FUTURE DISPATCH