Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Shark® 100Meter/Transducer
Shark® 100TTransducer Only
ww
w.e
lect
roin
d.co
m
Electro Industries/GaugeTech
MULTIFUNCTION POWER AND ENERGY METERRevenue Grade
Features• 0.2%ClassEnergy andDemandMetering
• MeasurementsincludingVoltage, Current,Power,Frequency,Energy,etc.
• OptionalKYZPulseandIrDAPor t
• PowerQualityMeasurements(%THDand AlarmLimits)
• V-Switch™Technology-FieldUpgrade withoutRemovingInstalledMeter
• LargeBrightRedLEDDisplay
• %ofLoadBarforAnalogMeterPerception
• OptionalRS485ModbusandDNP3.0Protocols
• Optional100BaseTEthernet
• FitsBothANSIandDINCut-Outs
• AvailableinaTransducer-OnlyVersion
Applications• UtilityMetering
• CommercialMetering
• Substations
• IndustrialMetering
• PowerGeneration
• CampusMetering
• Submetering
• AnalogMeterReplacement
Introduction
SH RK®100
High Performance and Economical Pricing for High Volume Deployment
ElectroIndustriesintroducesoneoftheindustry’shighestperformancerevenuegradepanelmeters.Basedonanallnewplatform,thislowcostmetersignificantlyoutperformsotherdevicesmanytimesitsprice.Thisunitisperfectfornewmeteringapplicationsandasasimplereplacementofexistinganalogmeters.TheShark®
meterexcelsinmeteringenergyaccurately,exceedingANSIC12.20(0.2%)andIEC687(0.2%)energymeasurementstandards.TheunitutilizeshighspeedDSPtechnologywithhighresolutionA/Dconversiontoproviderevenuecer tifiableaccuracyforUtilityBilling,SubstationMetering,SubmeteringandCriticalMeteringapplications.
New Ethernet
TCP/IP OptionNew Ethernet
TCP/IP Option
Superior Accuracy and Virtual Upgrade Switches
Easy to Use and Install
SHARK®100 METER
Fromuserinterfacetomechanicalconstruction,theShark®100Meterwasdesignedtobeeasyandintuitive,soaninstallerwithminimalmeterexperienceandtrainingcaneasilyinstallandusethisproduct.
Easytousefaceplateprogramming•PCsetup•PDAsetupusingIrDAport•Phasordiagramshowingwiringstatus•
Autoscrollfeature•Analogstyle%ofLoadBar•Shallowpaneldepth•Colorcoordinatedvoltageandcurrentinputs•
V-SWITCh™ TechnologyTheShark®100meterisequippedwithEIG’sexclusiveV-SwITCHtechnology.Thistechnologyallowsuserstoupgradeandaddfeaturesasneededbyusingcommunicationcommands,evenafterthemeterisinstalled.Available V-SwiTcheS:
V-Switch1–VoltsandAmpsMeter–Default•
V-Switch2–Volts,Amps,kw,kVAR,PF,kVA,Freq.•
V-Switch3–Volts,Amps,kw,kVAR,PF,kVA,Freq.kwh,kVAh,• kVARhandDNP3.0
V-Switch4–Volts,Amps,kw,kVAR,PF,kVA,Freq.kwh,kVAh,• kVARh,%THDMonitoring,LimitExceededAlarmsandDNP3.0
Traceable Watt-hour Test Pulse for Accuracy VerificationTheShark®100deviceisatraceablerevenuemeter.Itcontainsautilitygradetestpulseallowingpowerproviderstoverifyandconfirmthatthemeterisperformingtoitsratedaccuracy.Thisisanessentialfeaturerequiredofallbillinggrademeters.Additional Features include:
UtilityBlockandRollingAverageDemand•
AdjustableDemandProfiles•
MaxandMinAvailableonMostOtherParameters•
VoltageProvidesInstantaneousMaxandMinforSurgeandSagLimits•
Back Mounted Communication Port with KYZ Pulse RS485(Option485P)• –ThisportallowsRS485communicationusingModbusorDNP3.0Protocols.Baudratesarefrom9600to57.6k.
Ethernet(OptionINP10)• –10/100BaseTEthernetwithModbusTCPprotocol.
KYZPulse• –InadditiontotheRS485,themeteralsoincludesaKYZpulsemappedto positiveenergy.Thisisafixedenergypulse.Pulsevaluesare: K(h)atTestVoltslessthan150V=0.0501151926 K(h)atTestVoltsmorethan150V=0.2004607704
Front Mounted IrDA CommunicationUniquely,theShark®meteralsohasanopticalIrDAport,allowingtheunittobesetupandprogrammedusingaPDAorremotelaptopwithoutneedforacommunicationcable.Toconfigurethemeter,justpointatitwithanIrDA-equippedPCorPDA.COPILOTEXTisawindowsPocketPCsoftwarepackagethatallowsyoutoeasilyconfiguretheShark®100meterandpollreadings.
Note: Typical results are more accurate. Applies to 3 element wYe and 2 element Delta connections. Add 0.1% of Full Scale plus 1 digit to Accuracy specs for 2.5 element connections.
Advanced Communication Capability with IrDA InterfaceTheShark®100meterprovidestwoindependentcommunicationportswithadvancedfeatures.
Measured Parameters
Accuracy % of Reading
Display Range
Voltage L-N 0.1% 0-9999 Scalable V or kV
Voltage L-L 0.1% 0-9999 V or kV Scalable
current 0.1% 0-9999 Amps or kAmps
+/- watts 0.2% 0-9999 watts, kwatts, Mwatts
+/-wh 0.2% 5 to 8 Digits Programmable
+/-VARs 0.2% 0-9999 VARs, kVARs, MVARs
+/-VARh 0.2% 5 to 8 Digits Programmable
VA 0.2% 0-9999 VA, kVA, MVA
VAh 0.2% 5 to 8 Digits Programmable
PF 0.2% +/- 0.5 to 1.0
Frequency 0.01 hz 45 to 65 hz
%ThD 5.0% 0 to 100%
% Load Bar 1-120% 10 Digit Resolution Scalable
Measured Values Real-Time Avg Max Min
Voltage L-N • • •Voltage L-L • • •current Per Phase • • •watts • • • •VAr • • • •VA • • • •PF • • • •+watt-hr •-watt-hr •watt-hr net •+VAR-hr •-VAR-hr •VAR-hr net •VA-hr •Frequency • • •%ThD • • •Voltage Angles •current Angles •% of Load Bar •
Serial RS485
Direct PDA interface
cOPiLOT eXT (windowsPocketPC)
wireless irDA communication Serial
Modbus or DNP 3.0 Masterhost
(OR)
Modbus TcP 10/100 BaseT
(RJ45)
Masterhost
SiDe View
NickelPlatedBrassCurrent
"Gill"
SiDe View ReAR ViewFRONT View
RS485Communication
UniversalVoltageInputs
Current“Gills”
Only3.25”TxRxIndicator
LEDs
color-coordinatedinputs
}
ReAR View
IrDAPort
%LoadBar
ReadingTypeDesignator
Large.56"LEDs
ScreenSelectors
AutoScaleIndicator
FRONT View
whPulse
Wiring Diagrams
SHARK®100 METER
TheShark®100meterisruggedlydesignedforharshelectricalapplicationsinbothhighvoltageandlowvoltagepowersystems.ThisisespeciallyimportantinPowerGeneration,UtilitySubstationandCriticalUserapplications.Thestructuralandelectricaldesignofthismeterwasdevelopedbasedontherecommendationsandapprovalofmanyofourutilitycustomers.
high Isolation Universal Voltage InputsVoltageinputsallowmeasurementofupto416VoltsLinetoNeutraland721VoltsLinetoLine.Thisinsurespropermetersafetywhenwiringdirectlytohighvoltagesystems.Oneunitwillperformtospecificationon69Volt,120Volt,230Volt,277Voltand347Voltpowersystems.
Short Circuit Safe Current InputsCurrentinputsuseauniquedualinputmethod:
•Method One–CTLeadPassThrough.TheCTLeadpassesdirectlythroughthemeterwithoutanyphysicalterminationonthemeter.ThisinsuresthatthemetercannotbeapointoffailureontheCTcircuit.ThisispreferabletoutilityuserswhensharingrelayclassCTs.NoBurdenisaddedtothesecondaryCTcircuit.
•Method Two–Current“Gills.”Thisunitadditionallyprovidesultra-ruggedterminationpass-throughbars,allowingtheCTleadstobeterminatedonthemeter.TheShark®meter’sstud-baseddesigninsuresthatyourCTswillnotopeninafaultcondition.
Rugged and Safe Voltage and Current Inputs
Dimensional Drawings
CTLeadpassthroughwithtermination
Method One
Method TwoCTwiresterminatetometer
ANSIMounting
OptionNumbers:
example: Shark 100
Printed in China E 145702 032210 I
Voltage inputs•20-416VoltsLineToNeutral, 20-721VoltsLinetoLine
•UniversalVoltageInput
• InputWithstandCapability– MeetsIEEEC37.90.1(Surge WithstandCapability)
• ProgrammableVoltage RangetoAnyPTratio
•Supports:3ElementWYE, 2.5ElementWYE,2Element Delta,4WireDeltaSystems
•Burden:0.36VAperphaseMax at600V,0.014VAat120Volts
• Inputwiregaugemax(AWG 12/2.5mm2)
current inputs•Class10:(0to10)A,5AmpNominal
•Class2:(0to2)A,1ANominalSecondary
•FaultCurrentWithstand: 100Ampsfor10Seconds, 300Ampsfor3Seconds, 500Ampsfor1Second.
• ProgrammableCurrenttoAnyCTRatio
•Burden0.005VAperphase Maxat11Amps
•5mAPickupCurrent
• Passthroughwiregauge dimension:0.177"/4.5mm
•Continuouscurrentwithstand: 20ampsforscrewterminated orpassthroughcurrentconnections
isolationAllInputsandOutputsaregalvanically isolatedto2500VoltsAC.
environmental RatingStorage:(-40to+85)°C
Operating:(-20to+70)°C
Humidity:to95%RHNon-Condensing
FaceplateRating: NEMA12(WaterResistant)
MountingGasketIncluded
Sensing Method•RMS
•Samplingat400+Samplesper Cycleonallchannelsmeasured readingssimultaneously
•Harmonic%THD(%ofTotal HarmonicDistortion)
Update Rate•Watts,VArandVA-100msec
•Allotherparameters-1second
Power SupplyOptionD2:
• (90to265)VoltsACand (100to370)VoltsDC. UniversalAC/DCSupply
OptionD:
•18-60VDC Burden:10VAmax.
communication Format•2ComPorts(BackandFacePlate)
• RS485Port(ThroughBackPlate)
• 10/100BaseTEthernetModbusTCP(INP10)
• IrDA(ThroughFaceplate)
•ComPortBaudRate:(9600to57,600)
•ComPortAddress:0-247
•8Bit,Noparity
•ModbusRTU,ASCIIor DNP3.0Protocols
KYZ Pulse•TypeFormA
•OnResistance:23-35Wohm
•PeakVoltage:350VDC
•ContinuousLoadCurrent:120mA
•PeakLoadCurrent:350mA(10ms)
•OffStateLeakageCurrent@ 350VDC:1mA
• Opto-Isolation:3750V(60Hz,1min)
Dimensions and Shipping•Weight:2lbs
•BasicUnit:H4.85xW4.82xL4.25
•Shark100–mountsin92mm DINandANSIC39.4"Round Cut-outs
•Shark100T-DINrailmountedtransducer
•ShippingContainerDimensions: 6"cube
Meter Accuracy•Seepage2
compliance:• IEC687(0.2%Accuracy)
•ANSIC12.20(0.2%Accuracy)
•ANSI(IEEE)C37.90.1SurgeWithstand
•ANSIC62.41(Burst)
• IEC1000-4-2–ESD
• IEC1000-4-3–RadiatedImmunity
• IEC1000-4-4–FastTransient
• IEC1000-4-5–SurgeImmunity
communication converters9PINC–RS232Cable
CAB6490-USBtoIrDAAdapter
Unicom2500-RS485toRS232Converter
Unicom2500-F–RS485toRS232toFiberOpticConverter
ModemManager,Model#MM1–RS485toRS232ConverterforModemCommunication
compliance DocumentsCertificateofCalibration,Part#CCal–ThisprovidesCertificateofCalibrationwithNISTtraceableTestData.
Model
Shark100(Meter/Transducer)
Shark100T(Transducer Only)
Additional Accessories
Frequency
60
5050HzSystem
6060HzSystem
current class
10
105AmpSecondary
21AmpSecondary
cOM
X
XNoCom
485PRS485+Pulse
(Standard in Shark® 100T Transducer)
iNP1010/100BaseT+Pulse
--
--
V-Switch Pack
V2
V1DefaultV-SwitchVolts/Amps
V2AbovewithPower&Freq
V3AbovewithEnergyCounters
V4Abovewith%THD&Limits
--
--
Mounting(Shark100 Only)
X
XANSIMounting
DiNDINMountingBrackets
--
--
Power Supply
D2
D2(90-265)VACor(100-370)VDC
D18-60VDC
TheunitmountsdirectlyinanANSIC39.1(4"roundform)oranIEC92mmDINsquareform.Thisisperfectfornewinstallationsandforexistingpanels.Innewinstallations,simplyuseDINorANSIpunches.Forexistingpanels,pulloutoldanalogmetersandreplacethemwiththeShark®100meter.ThemeterusesstandardvoltageandcurrentinputssothatCTandPTwiringdoesnotneedtobereplaced.
Perfectforswitchgearpaneldirectretrofitspanel•
Usesminimalpanelspace•
Mountsinonly3.5"paneldepth•
Shark® 100 meter ANSI and DIN Mounting
DINMounting
DiN Mounting Brackets
SHARK®100 METER
Specifications
Ordering Information: To order, please fill out ordering guide:
Electro Industries/GaugeTech 1800ShamesDrive•westbury,NY11590
1- 877-EIMETER(1- 877-346-3837)•E-Mail: [email protected]
Tel:516-334-0870•Web Site:www.electroind.com•Fax:516-338-4741
Shark®100T-DINRailMountedTransducer