4
Shark ® 100 Meter/Transducer Shark ® 100T Transducer Only www.electroind.com Electro Industries/GaugeTech MULTIFUNCTION POWER AND ENERGY METER Revenue Grade Features • 0.2% Class Energy and Demand Metering • Measurements including Voltage, Current, Power, Frequency, Energy, etc. • Optional KYZ Pulse and IrDA Port • Power Quality Measurements (%THD and Alarm Limits) • V-Switch™ Technology - Field Upgrade without Removing Installed Meter • Large Bright Red LED Display • % of Load Bar for Analog Meter Perception • Optional RS485 Modbus and DNP 3.0 Protocols • Optional 100 BaseT Ethernet • Fits Both ANSI and DIN Cut-Outs • Available in a Transducer-Only Version Applications • Utility Metering • Commercial Metering • Substations • Industrial Metering • Power Generation • Campus Metering • Submetering • Analog Meter Replacement Introduction SH RK ® 100 High Performance and Economical Pricing for High Volume Deployment Electro Industries introduces one of the industry’s highest performance revenue grade panel meters. Based on an all new platform, this low cost meter significantly outperforms other devices many times its price. This unit is perfect for new metering applications and as a simple replacement of existing analog meters. The Shark® meter excels in metering energy accurately, exceeding ANSI C12.20 (0.2%) and IEC 687 (0.2%) energy measurement standards. The unit utilizes high speed DSP technology with high resolution A/D conversion to provide revenue certifiable accuracy for Utility Billing, Substation Metering, Submetering and Critical Metering applications. New Ethernet TCP/IP Option New Ethernet TCP/IP Option

SH RK 100 - S.A.EL

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SH RK 100 - S.A.EL

Shark® 100Meter/Transducer

Shark® 100TTransducer Only

ww

w.e

lect

roin

d.co

m

Electro Industries/GaugeTech

MULTIFUNCTION POWER AND ENERGY METERRevenue Grade

Features• 0.2%ClassEnergy andDemandMetering

• MeasurementsincludingVoltage, Current,Power,Frequency,Energy,etc.

• OptionalKYZPulseandIrDAPor t

• PowerQualityMeasurements(%THDand AlarmLimits)

• V-Switch™Technology-FieldUpgrade withoutRemovingInstalledMeter

• LargeBrightRedLEDDisplay

• %ofLoadBarforAnalogMeterPerception

• OptionalRS485ModbusandDNP3.0Protocols

• Optional100BaseTEthernet

• FitsBothANSIandDINCut-Outs

• AvailableinaTransducer-OnlyVersion

Applications• UtilityMetering

• CommercialMetering

• Substations

• IndustrialMetering

• PowerGeneration

• CampusMetering

• Submetering

• AnalogMeterReplacement

Introduction

SH RK®100

High Performance and Economical Pricing for High Volume Deployment

ElectroIndustriesintroducesoneoftheindustry’shighestperformancerevenuegradepanelmeters.Basedonanallnewplatform,thislowcostmetersignificantlyoutperformsotherdevicesmanytimesitsprice.Thisunitisperfectfornewmeteringapplicationsandasasimplereplacementofexistinganalogmeters.TheShark®

meterexcelsinmeteringenergyaccurately,exceedingANSIC12.20(0.2%)andIEC687(0.2%)energymeasurementstandards.TheunitutilizeshighspeedDSPtechnologywithhighresolutionA/Dconversiontoproviderevenuecer tifiableaccuracyforUtilityBilling,SubstationMetering,SubmeteringandCriticalMeteringapplications.

New Ethernet

TCP/IP OptionNew Ethernet

TCP/IP Option

Page 2: SH RK 100 - S.A.EL

Superior Accuracy and Virtual Upgrade Switches

Easy to Use and Install

SHARK®100 METER

Fromuserinterfacetomechanicalconstruction,theShark®100Meterwasdesignedtobeeasyandintuitive,soaninstallerwithminimalmeterexperienceandtrainingcaneasilyinstallandusethisproduct.

Easytousefaceplateprogramming•PCsetup•PDAsetupusingIrDAport•Phasordiagramshowingwiringstatus•

Autoscrollfeature•Analogstyle%ofLoadBar•Shallowpaneldepth•Colorcoordinatedvoltageandcurrentinputs•

V-SWITCh™ TechnologyTheShark®100meterisequippedwithEIG’sexclusiveV-SwITCHtechnology.Thistechnologyallowsuserstoupgradeandaddfeaturesasneededbyusingcommunicationcommands,evenafterthemeterisinstalled.Available V-SwiTcheS:

V-Switch1–VoltsandAmpsMeter–Default•

V-Switch2–Volts,Amps,kw,kVAR,PF,kVA,Freq.•

V-Switch3–Volts,Amps,kw,kVAR,PF,kVA,Freq.kwh,kVAh,• kVARhandDNP3.0

V-Switch4–Volts,Amps,kw,kVAR,PF,kVA,Freq.kwh,kVAh,• kVARh,%THDMonitoring,LimitExceededAlarmsandDNP3.0

Traceable Watt-hour Test Pulse for Accuracy VerificationTheShark®100deviceisatraceablerevenuemeter.Itcontainsautilitygradetestpulseallowingpowerproviderstoverifyandconfirmthatthemeterisperformingtoitsratedaccuracy.Thisisanessentialfeaturerequiredofallbillinggrademeters.Additional Features include:

UtilityBlockandRollingAverageDemand•

AdjustableDemandProfiles•

MaxandMinAvailableonMostOtherParameters•

VoltageProvidesInstantaneousMaxandMinforSurgeandSagLimits•

Back Mounted Communication Port with KYZ Pulse RS485(Option485P)• –ThisportallowsRS485communicationusingModbusorDNP3.0Protocols.Baudratesarefrom9600to57.6k.

Ethernet(OptionINP10)• –10/100BaseTEthernetwithModbusTCPprotocol.

KYZPulse• –InadditiontotheRS485,themeteralsoincludesaKYZpulsemappedto positiveenergy.Thisisafixedenergypulse.Pulsevaluesare: K(h)atTestVoltslessthan150V=0.0501151926 K(h)atTestVoltsmorethan150V=0.2004607704

Front Mounted IrDA CommunicationUniquely,theShark®meteralsohasanopticalIrDAport,allowingtheunittobesetupandprogrammedusingaPDAorremotelaptopwithoutneedforacommunicationcable.Toconfigurethemeter,justpointatitwithanIrDA-equippedPCorPDA.COPILOTEXTisawindowsPocketPCsoftwarepackagethatallowsyoutoeasilyconfiguretheShark®100meterandpollreadings.

Note: Typical results are more accurate. Applies to 3 element wYe and 2 element Delta connections. Add 0.1% of Full Scale plus 1 digit to Accuracy specs for 2.5 element connections.

Advanced Communication Capability with IrDA InterfaceTheShark®100meterprovidestwoindependentcommunicationportswithadvancedfeatures.

Measured Parameters

Accuracy % of Reading

Display Range

Voltage L-N 0.1% 0-9999 Scalable V or kV

Voltage L-L 0.1% 0-9999 V or kV Scalable

current 0.1% 0-9999 Amps or kAmps

+/- watts 0.2% 0-9999 watts, kwatts, Mwatts

+/-wh 0.2% 5 to 8 Digits Programmable

+/-VARs 0.2% 0-9999 VARs, kVARs, MVARs

+/-VARh 0.2% 5 to 8 Digits Programmable

VA 0.2% 0-9999 VA, kVA, MVA

VAh 0.2% 5 to 8 Digits Programmable

PF 0.2% +/- 0.5 to 1.0

Frequency 0.01 hz 45 to 65 hz

%ThD 5.0% 0 to 100%

% Load Bar 1-120% 10 Digit Resolution Scalable

Measured Values Real-Time Avg Max Min

Voltage L-N • • •Voltage L-L • • •current Per Phase • • •watts • • • •VAr • • • •VA • • • •PF • • • •+watt-hr •-watt-hr •watt-hr net •+VAR-hr •-VAR-hr •VAR-hr net •VA-hr •Frequency • • •%ThD • • •Voltage Angles •current Angles •% of Load Bar •

Serial RS485

Direct PDA interface

cOPiLOT eXT (windowsPocketPC)

wireless irDA communication Serial

Modbus or DNP 3.0 Masterhost

(OR)

Modbus TcP 10/100 BaseT

(RJ45)

Masterhost

Page 3: SH RK 100 - S.A.EL

SiDe View

NickelPlatedBrassCurrent

"Gill"

SiDe View ReAR ViewFRONT View

RS485Communication

UniversalVoltageInputs

Current“Gills”

Only3.25”TxRxIndicator

LEDs

color-coordinatedinputs

}

ReAR View

IrDAPort

%LoadBar

ReadingTypeDesignator

Large.56"LEDs

ScreenSelectors

AutoScaleIndicator

FRONT View

whPulse

Wiring Diagrams

SHARK®100 METER

TheShark®100meterisruggedlydesignedforharshelectricalapplicationsinbothhighvoltageandlowvoltagepowersystems.ThisisespeciallyimportantinPowerGeneration,UtilitySubstationandCriticalUserapplications.Thestructuralandelectricaldesignofthismeterwasdevelopedbasedontherecommendationsandapprovalofmanyofourutilitycustomers.

high Isolation Universal Voltage InputsVoltageinputsallowmeasurementofupto416VoltsLinetoNeutraland721VoltsLinetoLine.Thisinsurespropermetersafetywhenwiringdirectlytohighvoltagesystems.Oneunitwillperformtospecificationon69Volt,120Volt,230Volt,277Voltand347Voltpowersystems.

Short Circuit Safe Current InputsCurrentinputsuseauniquedualinputmethod:

•Method One–CTLeadPassThrough.TheCTLeadpassesdirectlythroughthemeterwithoutanyphysicalterminationonthemeter.ThisinsuresthatthemetercannotbeapointoffailureontheCTcircuit.ThisispreferabletoutilityuserswhensharingrelayclassCTs.NoBurdenisaddedtothesecondaryCTcircuit.

•Method Two–Current“Gills.”Thisunitadditionallyprovidesultra-ruggedterminationpass-throughbars,allowingtheCTleadstobeterminatedonthemeter.TheShark®meter’sstud-baseddesigninsuresthatyourCTswillnotopeninafaultcondition.

Rugged and Safe Voltage and Current Inputs

Dimensional Drawings

CTLeadpassthroughwithtermination

Method One

Method TwoCTwiresterminatetometer

Page 4: SH RK 100 - S.A.EL

ANSIMounting

OptionNumbers:

example: Shark 100

Printed in China E 145702 032210 I

Voltage inputs•20-416VoltsLineToNeutral, 20-721VoltsLinetoLine

•UniversalVoltageInput

• InputWithstandCapability– MeetsIEEEC37.90.1(Surge WithstandCapability)

• ProgrammableVoltage RangetoAnyPTratio

•Supports:3ElementWYE, 2.5ElementWYE,2Element Delta,4WireDeltaSystems

•Burden:0.36VAperphaseMax at600V,0.014VAat120Volts

• Inputwiregaugemax(AWG 12/2.5mm2)

current inputs•Class10:(0to10)A,5AmpNominal

•Class2:(0to2)A,1ANominalSecondary

•FaultCurrentWithstand: 100Ampsfor10Seconds, 300Ampsfor3Seconds, 500Ampsfor1Second.

• ProgrammableCurrenttoAnyCTRatio

•Burden0.005VAperphase Maxat11Amps

•5mAPickupCurrent

• Passthroughwiregauge dimension:0.177"/4.5mm

•Continuouscurrentwithstand: 20ampsforscrewterminated orpassthroughcurrentconnections

isolationAllInputsandOutputsaregalvanically isolatedto2500VoltsAC.

environmental RatingStorage:(-40to+85)°C

Operating:(-20to+70)°C

Humidity:to95%RHNon-Condensing

FaceplateRating: NEMA12(WaterResistant)

MountingGasketIncluded

Sensing Method•RMS

•Samplingat400+Samplesper Cycleonallchannelsmeasured readingssimultaneously

•Harmonic%THD(%ofTotal HarmonicDistortion)

Update Rate•Watts,VArandVA-100msec

•Allotherparameters-1second

Power SupplyOptionD2:

• (90to265)VoltsACand (100to370)VoltsDC. UniversalAC/DCSupply

OptionD:

•18-60VDC Burden:10VAmax.

communication Format•2ComPorts(BackandFacePlate)

• RS485Port(ThroughBackPlate)

• 10/100BaseTEthernetModbusTCP(INP10)

• IrDA(ThroughFaceplate)

•ComPortBaudRate:(9600to57,600)

•ComPortAddress:0-247

•8Bit,Noparity

•ModbusRTU,ASCIIor DNP3.0Protocols

KYZ Pulse•TypeFormA

•OnResistance:23-35Wohm

•PeakVoltage:350VDC

•ContinuousLoadCurrent:120mA

•PeakLoadCurrent:350mA(10ms)

•OffStateLeakageCurrent@ 350VDC:1mA

• Opto-Isolation:3750V(60Hz,1min)

Dimensions and Shipping•Weight:2lbs

•BasicUnit:H4.85xW4.82xL4.25

•Shark100–mountsin92mm DINandANSIC39.4"Round Cut-outs

•Shark100T-DINrailmountedtransducer

•ShippingContainerDimensions: 6"cube

Meter Accuracy•Seepage2

compliance:• IEC687(0.2%Accuracy)

•ANSIC12.20(0.2%Accuracy)

•ANSI(IEEE)C37.90.1SurgeWithstand

•ANSIC62.41(Burst)

• IEC1000-4-2–ESD

• IEC1000-4-3–RadiatedImmunity

• IEC1000-4-4–FastTransient

• IEC1000-4-5–SurgeImmunity

communication converters9PINC–RS232Cable

CAB6490-USBtoIrDAAdapter

Unicom2500-RS485toRS232Converter

Unicom2500-F–RS485toRS232toFiberOpticConverter

ModemManager,Model#MM1–RS485toRS232ConverterforModemCommunication

compliance DocumentsCertificateofCalibration,Part#CCal–ThisprovidesCertificateofCalibrationwithNISTtraceableTestData.

Model

Shark100(Meter/Transducer)

Shark100T(Transducer Only)

Additional Accessories

Frequency

60

5050HzSystem

6060HzSystem

current class

10

105AmpSecondary

21AmpSecondary

cOM

X

XNoCom

485PRS485+Pulse

(Standard in Shark® 100T Transducer)

iNP1010/100BaseT+Pulse

--

--

V-Switch Pack

V2

V1DefaultV-SwitchVolts/Amps

V2AbovewithPower&Freq

V3AbovewithEnergyCounters

V4Abovewith%THD&Limits

--

--

Mounting(Shark100 Only)

X

XANSIMounting

DiNDINMountingBrackets

--

--

Power Supply

D2

D2(90-265)VACor(100-370)VDC

D18-60VDC

TheunitmountsdirectlyinanANSIC39.1(4"roundform)oranIEC92mmDINsquareform.Thisisperfectfornewinstallationsandforexistingpanels.Innewinstallations,simplyuseDINorANSIpunches.Forexistingpanels,pulloutoldanalogmetersandreplacethemwiththeShark®100meter.ThemeterusesstandardvoltageandcurrentinputssothatCTandPTwiringdoesnotneedtobereplaced.

Perfectforswitchgearpaneldirectretrofitspanel•

Usesminimalpanelspace•

Mountsinonly3.5"paneldepth•

Shark® 100 meter ANSI and DIN Mounting

DINMounting

DiN Mounting Brackets

SHARK®100 METER

Specifications

Ordering Information: To order, please fill out ordering guide:

Electro Industries/GaugeTech 1800ShamesDrive•westbury,NY11590

1- 877-EIMETER(1- 877-346-3837)•E-Mail: [email protected]

Tel:516-334-0870•Web Site:www.electroind.com•Fax:516-338-4741

Shark®100T-DINRailMountedTransducer