1
LV-247 Bulletin # LCDTV-197 Page 1 of 1 Technical Bulletin Number: LCDTV-197 Date: October 2007 Model(s): LC42D64U / LC46D64U / LC52D64U / LC65D64U LCD Television Subject: Momentary power interruptions cause the Aquos link to become inoperative. Countermeasure: Upgrade unit with latest firmware version 1.04. The new firmware can resolve the following occurrence: After momentary power interruptions (within one second) can cause Aquos link inoperative. In this case, please upgrade the monitor firmware to 1.04. Monitor Software Version Firmware File 1.04 SALEM104.BIN Please refer to the service manual(s) for the upgrade procedure. When servicing these models, please upgrade the monitor firmware to version 1.04 or later by using a USB memory device. Please go to SharpNet (www.sharp-service.com ) Technical Channel downloads to get latest firmware versions. Note1: All user data settings are not reset when the monitor firmware is upgraded by using the USB memory device. Please reinitialize the TV (INDUSTRIAL INIT) after each upgrade. The user settings will then be set to the default settings. Note2: The firmware can be downloaded from SharpNet. Note3: The progress screen for this firmware upgrade may take up to 1 minute to appear. Before removing USB device, please unplug AC cord to restart upgrade process (if needed). Sharp Electronics Corporation Services and Solutions Group 1300 Naperville Drive Romeoville, IL 60446

Sharp Lcdtv-197 Lc42d64u Lc46d64u Lc52d64u Lc65d64u Tech Bulletin

Embed Size (px)

DESCRIPTION

Sharp firmware

Citation preview

Page 1: Sharp Lcdtv-197 Lc42d64u Lc46d64u Lc52d64u Lc65d64u Tech Bulletin

LV-247 Bulletin # LCDTV-197 Page 1 of 1

Technical Bulletin Number: LCDTV-197 Date: October 2007 Model(s): LC42D64U / LC46D64U / LC52D64U / LC65D64U

LCD Television

Subject: Momentary power interruptions cause the Aquos link to become inoperative. Countermeasure: Upgrade unit with latest firmware version 1.04.

The new firmware can resolve the following occurrence:

After momentary power interruptions (within one second) can cause Aquos link inoperative.

In this case, please upgrade the monitor firmware to 1.04.

Monitor Software

Version Firmware File

1.04 SALEM104.BIN

Please refer to the service manual(s) for the upgrade procedure.

When servicing these models, please upgrade the monitor firmware to version 1.04 or later by using a USB memory device. Please go to SharpNet (www.sharp-service.com) Technical Channel ►downloads to get latest firmware versions.

Note1: All user data settings are not reset when the monitor firmware is upgraded by using the USB memory device. Please reinitialize the TV (INDUSTRIAL INIT) after each upgrade. The user settings will then be set to the default settings.

Note2: The firmware can be downloaded from SharpNet.

Note3: The progress screen for this firmware upgrade may take up to 1 minute to appear. Before removing USB device, please unplug AC cord to restart upgrade process (if needed).

Sharp Electronics Corporation Services and Solutions Group

1300 Naperville Drive Romeoville, IL 60446