Sheet
Date
Drawing Name
System
Substrate
1 : 2 @ A4
77.00.00Drawing Register
1 November 2017
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Sheet List Table
Sheet Number Sheet Title
77.00.00 Drawing Regeister
77.02.00 Foundation
77.04.00 Internal Corner
79.03.00External Corner
77.05.00Window Sill
77.06.00 Window Jamb
77.07.00 Window Head
77.08.00Soffit
77.09.00Roof Apron
77.10.00 Vertical Control Joint
77.11.00 Horizontal Control Joint
Building Underlay
50 m
inim
um
Refer to N
ZBC E2/AS1 for inform
ation
on G
round Clearances
20 50 5
Refer to NZBC E2/AS1 for information
on Ground Clearances
Reinforcing Mesh
Vertical Batten Supplied and
Installed by main Applicator
Fastener
DPC
Universal Starter Strip
can be used in place
of the Clip-On Starter
Strip where preferred
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction
Systems Insulated Facade
System
RCS Channel Flashing
RCS Cavity Closer
Sheet Drawing Name
77.02.00
Foundation
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
20 50 5
Building Underlay continuous
around corner
Reinforcing Mesh
Pre Meshed Corner Flashing
Vertical Batten Supplied and
Installed by main Applicator
Fastener
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction
Systems Insulated Facade
System
Sheet Drawing Name
77.03.00
External Corner
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
50
20
5
Reinforcing Mesh
Building Underlay continuous
around corner
Mesh to be wrapped continuously
around the internal corner, if there is
a break in the mesh then an additional
layer of Sticky Mesh must be used
Vertical Batten Supplied and
Installed by main Applicator
Fastener
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
Sheet Drawing Name
77.04.00
Internal Corner
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Allow a 25mm Gap between the back of
the joinery and external facing SIPS to
allow the sill flashing to fit.
MS Sealant
Sticky Mesh
RCS EdgeSeal Flashing
Reinforcing Mesh
Building Underlay
55020
Vertical Batten Supplied
and Installed by main
Applicator
Fastener
Sill Flashing Tape supplied and
installed by the main contractor
to be run continuously along the
sill and 100mm up jambs and
50mm onto the building wrap
Air Seal
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
50m
m m
inim
um
Sheet Drawing Name
77.05.00
Window Sill
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
MS Sealant
Sticky Mesh
RCS EdgeSeal Flashing
Reinforcing Mesh
Sill Flashing Tape supplied and
installed by the main contractor
(minimum 100mm up jamb)
Building Underlay
Vertical Batten Supplied
and Installed by main
Applicator
Allow a 25mm Gap between the back of
the joinery and external facing timber
framing to allow the jamb flashing to fit.
20
50
5
Fastener
Air Seal
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
Sheet Drawing Name
77.06.00
Window Jamb
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Reinforcing Mesh
Building Underlay
Vertical Batten Supplied and
Installed by main Applicator
20505
Fastener
Sill Flashing Tape to corners
supplied and installed by the
main contractor
Air Seal
Drip Edge Flashing
RCS EdgeSeal
Head Flashing
3M All Weather
Flashing Tape 8067
from Building Underlay
to Head Flashing.
3M All Weather
Flashing Tape 8067 to
be installed against
jamb batten to form
stopend
The RCS EdgeSeal Head Flashing must
be installed so that it extends 10mm
either side of the jamb extrusion.
Resene Construction Systems
Insulated Facade System
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Sheet
Drawing Name
77.07.00
Window Head
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Reinforcing Mesh
MS Sealant
Building Underlay
Continuous Batten supplied
and installed by the
applicator (cavity to be
closed off)
55020
Fastener
Vertical Batten Supplied and
Installed by main Applicator
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
Sheet Drawing Name
77.08.00
Soffit
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
35m
m
Reinforcing Mesh
Building Underlay
Vertical Batten Supplied and
Installed by main Applicator
Refer RCS TradeSpec™
Document 1.2 for information
on Roof Clearances
Metal flashing must be taped to the
Building Underlay or covered with a
second layer of wrap by the main
contractor/window installer
Apron Flashing supplied and
installed by the main
contractor, building underlay
wrapped over flashing (75mm
cover to cladding)
55020
Kick out Flashing
Fastener
Universal Starter Strip
can be used in place
of the Clip-On Starter
Strip where preferred
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
RCS Channel Flashing
RCS Cavity Closer
Sheet Drawing Name
77.09.00
Roof Apron
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Reinforcing Mesh
All Control Joint spacings and setouts
are the responsibility of the
Designer, for suggested locations refer
to RCS TradeSpec™ Document 1.4
550
20
MS Sealant
PEF Rod
10
Building Underlay
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Resene Construction Systems
Insulated Facade System
Vertical Batten Supplied and
Installed by main Applicator
Sheet Drawing Name
77.10.00
Vertical Control Joint
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System
XTherm Blue Panel 50mm (20mm Cavity) - SIPS
Typical Floor Joist
30m
m
Reinforcing Mesh
Slip Joint Flashing
Building Underlay
75020
10
MS Sealant is Optional
Please note that there should be no fixings into the
floor joists, the substrate should be left floating over
this point.
All Control Joint spacings and setouts are the
responsibility of the Designer, for suggested
locations refer to TradeSpec™ Document 1.4 for
suggested locations
Vertical batten supplied
and installed by the
applicator
Resene Construction Systems
Insulated Facade System
XTherm Blue Panel 50mm
(20mm Cavity) - SIPS
Sheet Drawing Name
77.11.00
Horizontal Control Joint
CONFIDENTIALITY: No part of this publication may be
reproduced or transmitted other than the intended use by
Resene Construction Systems without written consent from
the author.
TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems
Scale
Date
System
Substrate
1 : 2 @ A4
1 November 2017
Insulated Facade System