11
Scale Sheet Date Drawing Name System Substrate 1 : 2 @ A4 77.00.00 Drawing Register 1 November 2017 CONFIDENTIALITY: No part of this publication may be reproduced or transmitted other than the intended use by Resene Construction Systems without written consent from the author. TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems Insulated Facade System XTherm Blue Panel 50mm (20mm Cavity) - SIPS Sheet List Table Sheet Number Sheet Title 77.00.00 Drawing Regeister 77.02.00 Foundation 77.04.00 Internal Corner 79.03.00 External Corner 77.05.00 Window Sill 77.06.00 Window Jamb 77.07.00 Window Head 77.08.00 Soffit 77.09.00 Roof Apron 77.10.00 Vertical Control Joint 77.11.00 Horizontal Control Joint

Sheet List Table Sheet Number Sheet Title 77.04.00

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Sheet List Table Sheet Number Sheet Title 77.04.00

Scale

Sheet

Date

Drawing Name

System

Substrate

1 : 2 @ A4

77.00.00Drawing Register

1 November 2017

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Sheet List Table

Sheet Number Sheet Title

77.00.00 Drawing Regeister

77.02.00 Foundation

77.04.00 Internal Corner

79.03.00External Corner

77.05.00Window Sill

77.06.00 Window Jamb

77.07.00 Window Head

77.08.00Soffit

77.09.00Roof Apron

77.10.00 Vertical Control Joint

77.11.00 Horizontal Control Joint

Page 2: Sheet List Table Sheet Number Sheet Title 77.04.00

Building Underlay

50 m

inim

um

Refer to N

ZBC E2/AS1 for inform

ation

on G

round Clearances

20 50 5

Refer to NZBC E2/AS1 for information

on Ground Clearances

Reinforcing Mesh

Vertical Batten Supplied and

Installed by main Applicator

Fastener

DPC

Universal Starter Strip

can be used in place

of the Clip-On Starter

Strip where preferred

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction

Systems Insulated Facade

System

RCS Channel Flashing

RCS Cavity Closer

Sheet Drawing Name

77.02.00

Foundation

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 3: Sheet List Table Sheet Number Sheet Title 77.04.00

20 50 5

Building Underlay continuous

around corner

Reinforcing Mesh

Pre Meshed Corner Flashing

Vertical Batten Supplied and

Installed by main Applicator

Fastener

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction

Systems Insulated Facade

System

Sheet Drawing Name

77.03.00

External Corner

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 4: Sheet List Table Sheet Number Sheet Title 77.04.00

50

20

5

Reinforcing Mesh

Building Underlay continuous

around corner

Mesh to be wrapped continuously

around the internal corner, if there is

a break in the mesh then an additional

layer of Sticky Mesh must be used

Vertical Batten Supplied and

Installed by main Applicator

Fastener

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

Sheet Drawing Name

77.04.00

Internal Corner

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 5: Sheet List Table Sheet Number Sheet Title 77.04.00

Allow a 25mm Gap between the back of

the joinery and external facing SIPS to

allow the sill flashing to fit.

MS Sealant

Sticky Mesh

RCS EdgeSeal Flashing

Reinforcing Mesh

Building Underlay

55020

Vertical Batten Supplied

and Installed by main

Applicator

Fastener

Sill Flashing Tape supplied and

installed by the main contractor

to be run continuously along the

sill and 100mm up jambs and

50mm onto the building wrap

Air Seal

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

50m

m m

inim

um

Sheet Drawing Name

77.05.00

Window Sill

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 6: Sheet List Table Sheet Number Sheet Title 77.04.00

MS Sealant

Sticky Mesh

RCS EdgeSeal Flashing

Reinforcing Mesh

Sill Flashing Tape supplied and

installed by the main contractor

(minimum 100mm up jamb)

Building Underlay

Vertical Batten Supplied

and Installed by main

Applicator

Allow a 25mm Gap between the back of

the joinery and external facing timber

framing to allow the jamb flashing to fit.

20

50

5

Fastener

Air Seal

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

Sheet Drawing Name

77.06.00

Window Jamb

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 7: Sheet List Table Sheet Number Sheet Title 77.04.00

Reinforcing Mesh

Building Underlay

Vertical Batten Supplied and

Installed by main Applicator

20505

Fastener

Sill Flashing Tape to corners

supplied and installed by the

main contractor

Air Seal

Drip Edge Flashing

RCS EdgeSeal

Head Flashing

3M All Weather

Flashing Tape 8067

from Building Underlay

to Head Flashing.

3M All Weather

Flashing Tape 8067 to

be installed against

jamb batten to form

stopend

The RCS EdgeSeal Head Flashing must

be installed so that it extends 10mm

either side of the jamb extrusion.

Resene Construction Systems

Insulated Facade System

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Sheet

Drawing Name

77.07.00

Window Head

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 8: Sheet List Table Sheet Number Sheet Title 77.04.00

Reinforcing Mesh

MS Sealant

Building Underlay

Continuous Batten supplied

and installed by the

applicator (cavity to be

closed off)

55020

Fastener

Vertical Batten Supplied and

Installed by main Applicator

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

Sheet Drawing Name

77.08.00

Soffit

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 9: Sheet List Table Sheet Number Sheet Title 77.04.00

35m

m

Reinforcing Mesh

Building Underlay

Vertical Batten Supplied and

Installed by main Applicator

Refer RCS TradeSpec™

Document 1.2 for information

on Roof Clearances

Metal flashing must be taped to the

Building Underlay or covered with a

second layer of wrap by the main

contractor/window installer

Apron Flashing supplied and

installed by the main

contractor, building underlay

wrapped over flashing (75mm

cover to cladding)

55020

Kick out Flashing

Fastener

Universal Starter Strip

can be used in place

of the Clip-On Starter

Strip where preferred

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

RCS Channel Flashing

RCS Cavity Closer

Sheet Drawing Name

77.09.00

Roof Apron

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 10: Sheet List Table Sheet Number Sheet Title 77.04.00

Reinforcing Mesh

All Control Joint spacings and setouts

are the responsibility of the

Designer, for suggested locations refer

to RCS TradeSpec™ Document 1.4

550

20

MS Sealant

PEF Rod

10

Building Underlay

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Resene Construction Systems

Insulated Facade System

Vertical Batten Supplied and

Installed by main Applicator

Sheet Drawing Name

77.10.00

Vertical Control Joint

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System

XTherm Blue Panel 50mm (20mm Cavity) - SIPS

Page 11: Sheet List Table Sheet Number Sheet Title 77.04.00

Typical Floor Joist

30m

m

Reinforcing Mesh

Slip Joint Flashing

Building Underlay

75020

10

MS Sealant is Optional

Please note that there should be no fixings into the

floor joists, the substrate should be left floating over

this point.

All Control Joint spacings and setouts are the

responsibility of the Designer, for suggested

locations refer to TradeSpec™ Document 1.4 for

suggested locations

Vertical batten supplied

and installed by the

applicator

Resene Construction Systems

Insulated Facade System

XTherm Blue Panel 50mm

(20mm Cavity) - SIPS

Sheet Drawing Name

77.11.00

Horizontal Control Joint

CONFIDENTIALITY: No part of this publication may be

reproduced or transmitted other than the intended use by

Resene Construction Systems without written consent from

the author.

TradeSpec™ and RenderSpec™ are Registered Trademarks, both Documents are available on the Resene Construction Systems

Scale

Date

System

Substrate

1 : 2 @ A4

1 November 2017

Insulated Facade System