I N S T A L L A T I O N A N D U S E R M A N U A L

G S M V O H 1 0 0 1

Page 2: Shield 200 EasyProtect Kit - English Manual

1 . S t at u s / G S M S i g n al I n d i c at o r2 . P o w e r s t a t u s I n d i c a t o r3. P an i c ( S O S )4 . P an e l5 . S t an d6 . M o n i t o r i n g M I C

SIM 1 . S I M C a r d S l o t2 . C o n n e c t 3. P o w e r 4 . A d a p t e r I n t e r f ac e5 . U S B U p g r ad e P o r t

2 3

- 32 - b i t h i g h s p e e d p r o c e s s o r , r e l i a b l e c ap ab i l i t y- 1 0 0 % w i r e l e s s D . I . Y . - B u i l t - i n 1 , 0 0 0 , 0 0 0 R F c o d e s- S u p p o r t s 1 0 r e m o t e c o n t r o l s an d 1 0 0 w i r e l e s s s e n s o r s .- T h e a l ar m s y s t e m c an b e c o n t r o l l e d b y S M S , A p p o r p h o n e c al l - S t o r e s 5 p h o n e n u m b e r s an d 5 S M S n u m b e r s f o r al ar m al e r t - S u p p o r t s e x i t an d e n t r y d e l a y ar m / al e r t- W i r e l e s s s e l f - l e ar n i n g c o d e- A d d i n g n e w ac c e s s o r i e s f a s t an d e a s y- S u p p o r t s ar m an d d i s ar m b y A p p- S u p p o r t s r e m o t e m o n i t o r b y A p p- S u p p o r t s r e m o t e c o n t r o l / ar m / d i s ar m / m o n i t o r b y p h o n e- S M S f o r p o w e r p o w e r r e c o v e r y an d l o w - S u p p o r t s g l o b a l G S M 85 0 / 90 0 / 1 80 0 / 1 90 0 M H z

C o n tro l P an e l F e atu re s

F e atu re s

1 . S tatu s / L o w P o w e r I n d i c ato r

B l u e s y s t e m i s ar m e dB l u e t h e al ar m h as b e e n t r i g g e r e d

2 . P o w e r / G S M S i g n al I n d i c ato r

P r o d u c t S h i e l d 2 0 0

P o w e r s u p p lI n p u t A C 1 1 0 ~ 2 4 0 V / 5 0 ~ 6 0 H z

D C 1 2 V / 1 A

G S M w o r k i n g f r85 0 / 90 0 / 1 80 0 / 1 90 0 M H z

S t an d b y c u r r e n6 0 m A h

A l ar m c u r r e n1 2 0 m A h

B u i l t - i n 7 . 4 V 6 0 0 m A h l i t h i u m

S u p p o r t w i r e l e s s 1 0 r e m o t e c o n t r o l , 1 0 0 w i r e l e s s d e t e c t o r s

W i r e l e s s r e c e i v i n g f r 4 33M H z ( ± 7 5 K H z )

S i r e n v 90 d B

H o u s i n g m a tA B S

T e m p e r a t u r - 1 0 ° C ~ + 5 5 ° C ≤80%

( n o n - c o n d e n s i n g )

Page 3: Shield 200 EasyProtect Kit - English Manual

4 5

Quick Start-up Guide

First

Store a phone numberTo interact with the control panel by SMS, by phone call and/or from the app, at least one phone number must be stored in the control panel. Please refer to the on “Store Phone Numbers” on page 7 of this manual.

Change the languageBy default the language of the kit control panel is set to English. If you wish to change the system language, refer to the “Change system language” on page 12 of this manual. “System language” refers to the language of the SMS you receive from the control panel.

Arm / Disarm the system

The alarm system can be armed or disarmed by SMS, by App and by phone call.

By SMS To arm the system: Send “1” by SMS to the number of your system’s SIM card.To disarm the system: Send “0” by SMS to the number of your system’s SIM card.

By appClick on “Arm” in the app to arm the system, and “Disarm” to disarm the system. The app is available for download on the App Store and Google Play.

Register wireless accessories

Control by Phone Call

Method 1When an alarm has been triggered, the control panel dials the pre-stored phone numbers. When you pick up the phone, control the panel from distance according to the in the table below).

Method 21. Dial the telephone number of the SIM card in your control panel.2. Enter your user code, followed by ”#”. ey you press on your phone, you hear one beep

3. Select the to control the panel (see in the table below).

NoteThe call will end ally if you do not send any command within 30 seconds.

Voice

Command

Press “1“ Arms the system

Press “0“ --

--

--

- Stops monitoring without hanging up

Press “ “

Press “6“ Turns all sirens

Press “9“

Press “#“ -- Exits control by phone call

- Stops call recycles

NoteIn GSM mode, the audio monitoring is not limited in

Hard Reset

Press the Connect and the Panic (SOS) simultaneously. Release them 3 beeps. Wait 10 seconds. The panel beeps twice: the system is restored to default Stored phone numbers and accessories will also be deleted.

successful.

If the accessory has already been registered, the control panel will beep twice. The first accessoryregistered is assigned to zone 1, the second accessory registered is assigned to zone 2, etc. Zones

learn how to rename zones).

Disarms the system and turns the siren off

Stops the built-in siren and the wireless siren (if connected to the control panel)

Turns the wireless siren on (if connected to the control panel)

Turns all sirens off

Page 4: Shield 200 EasyProtect Kit - English Manual

6 7

Zone setup of accessories

Every detector can be assigned to 4 t categories of zones: Home Mode Zone, Delay Zone, Normal Zone and 24-H Zone. To assign a detector to a zone, open its case and move its jumpers according to the drawing below:

D0

D3

D0

D3D0

D3 D3

D0

A. Home Mode Zone B. Delay Zone C. Normal Zone D. 24-H Zone

Normal zoneWhen the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed, sensors do not trigger an alarm.

24h zoneRegardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm. It is recommended to set smoke detectors, gas detectors and outdoor beam sensors in the 24-H zone.

Delay zoneAn entry and an exit delay can be set. In such case, sensors assigned to the “Delay Zone” will not trigger an alarm during the of delay set. For example, if you assign a detector to the Delay zone and you set the Entry/Exit Delay to 30 seconds, the detector will not trigger an alarm within 30 seconds you enter your home and within 30 seconds before you leave it so that you can leave and enter your home without triggering an alarm. Refer to the on page 6 of this manual to learn how to set the entry and exit delay. It is recommended to assign the Door / Window Contact to the Delay zone.

Home zoneWhen the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an alarm. It is recarmed in Home Mode when you are home and move inside your home without triggering any alarm.

SMS

IMPORTANT: BEFORE USING FOR THE FIRST TIME

SAVE A PHONE NUMBER FOR SMS NOTIFICATIONS. (Refer to on the opposite column)Only stored numbers can control and

INSERT A SIM CARD IN THE CONTROL PANEL

Each SMS opera in this user manual will be illustrated as follows:

You send:

SMS Command

command sent by the user.

The control panel replies:

Control panel’s reply

by the control panel.

The speech bubbles that follow are the dialogue between the user and the control panel (SMS sent by the user are in pink, SMS sent by the control panel are in grey).

The system is in English by default. To change the system’s language, refer to page 12 of this manual.

Store Phone numbers for SMS

Send:

6

SMS numbers:1.2.3.4.5.

Copy, Paste, then Edit(case

SMS numbers:1. 0678900332. 0678900223. 0678900114. 0678900005.

Ok

7

BEFORE STARTING SMS OPERATIONS .

MAKE SURE THE SIM CARD DOES NOTREQUIRE ANY PIN CODE .

Page 5: Shield 200 EasyProtect Kit - English Manual

8 9

Disarm the System

Send:

0

System disarmed.

Arm the System

Send:

1

System armed.

Home Mode

Send:

2

System in home mode.

Enquiry

Send:

00

System:DisarmedAC power:onEntry delay Exit delay Siren Disarm password:1234

NoteThe value of default will be changed

er having set up the system.

Store Phone Numbers

Send:

5

Phone numbers:1.2.3.4.5.

Copy, Paste, then Edit(case e):

Phone numbers:1. 0678900332. 0678900223. 0678900114. 0678900005.

Ok

Change Zone Name

Send “91~99”. For example for zone 1, send:

91

Zones names:1.

Copy, Paste, then Edit(case e):

Zones names:1.Entrance door alarm

Ok

NoteZones 1 to 9 can be renamed. The name of the zone cannot consist of more than 30 characters per line due to SMS character limit. Zones 10 to 99 cannot be renamed.

Page 6: Shield 200 EasyProtect Kit - English Manual

10 11

SMS Alert for Accessory Low ery(available for two-way acessories such as

Detectors)

For accessories assigned to zones that have been renamed, an SMS will be sent under the format “Zone name + low ery”.

Bedroom PIR low

For accessories assigned to zones that have not been renamed, an SMS will be sent under the format “Zone number + low ery”.

Zone 10 low

SMS Alert for Accessory Tamper Alarm (available for two-way acessories such as

Detectors)

For accessories assigned to zones that have been renamed, an SMS will be sent under the format “Zone name + tamper alarm”.

Bedroom PIR tamper alarm.

For accessories assigned to zones that have not been renamed, an SMS will be sent under the format “Zone number + tamper alarm”.

Zone 10 tamper alarm.

Entry and Exit Delay Time

Send:

11

Entry delay Exit delay

Copy, Paste, then Edit(case

Entry delay Exit delay

Ok

NoteThis can be used if you do not want to bring a remote control or RFID tag with you. When the system is armed, you hear one beep every second to remind you to leave. The beep rhythm speeds up during the last 10 seconds. If an intruder is detected, the alarm will be delayed accordingly.

Siren Volume and Ringing Time

Send:

12

Siren volume(0=Mute,1=High):1Siren ringing

Copy, Paste, then Edit(case

Siren volume(0=Mute,1=High):0Siren ringing

Ok

Disarm Password

Send:

13

Disarm password (4 digits):1234

Copy, Paste, then Edit(case

Disarm password (4 digits):8888

Ok

Set Ringing Times

Send:

19

Ringing

Copy, Paste, then Edit(case

Ringing

This enables you to the number of the control panel rings before taking the call.

Ring can be set from 0 to 9. When set to 0, the alarm system will not ring when being called.

Page 7: Shield 200 EasyProtect Kit - English Manual

1312

Call repe

If the user does not pick up his phone when the alarm detects an intrusion, the alarm will keep re-dialing the number a certain amount of

Send:

20

Call

Copy, Paste, then Edit(case

Call

The number of call can be set from 1 to 9.

Delete all Wireless Accessories

Send:

21

Ok

Change system language

Send the code of the language. For example, for English, send “0001”.

0001

Ok

Refer to the table below for the full list of languages:

0001 English0002 French0004 Danish0006 Italian0007 Swedish0008 German

0009 Spanish0010 Finnish0011 Norwegian

Restore System to Factory by SMS

Send:

0000

Ok

The will be restored to default values. Stored phone numbers and connected accessories will also be deleted.Only stored numbers can send the SMS to restore factory

Accessories

Wireless Remote Control

Home ModeArm

SOSDisarm

LED indicator

Arm the system

Press the Arm " " to arm the alarm system. The LED indicator lights up (the siren rings out once). The system is armed.

If an intruder is detected, the siren rings out. (The siren turns 5 minutes as per default In the the system dials the pre-stored phone numbers

Disarm the system

Press the Disarm " " to disarm the alarm system. The LED indicator turns (the siren rings out twice). The system is disarmed.

Home Mode

Press the Home Mode " " on the remote control. The system state LED is on. All the sensors in regular zones are armed except those in the Home Mode zone. The sensors in the Home Mode zone are disarmed so that users can move inside their home.

0016 Czech

Page 8: Shield 200 EasyProtect Kit - English Manual

1514

Emergency Mode

Regardless the status of the system, the alarm is triggered when the SOS "SOS" is pressed on the remote control.At the same the control panel sends a

by SMS and dials the pre-stored phone numbers.

Register in the control panelPress the at the back of the control panel to enter the mode. Press any on of the remote control.

Power supply:DC 3V (CR2025 on ba x1)

Oper current:≤7 mA

St current:10 uA

Transmission distance≤ 80 m (in open area)

Radio-frequency:433MHz (±75KHz)

Housing material:ABS plas

cTemperature: -10°C ~ +55°CR Humidity: ≤80% (non-condensing)

Dimensions:57 x 31 x 11 mm

Wireless Detector

With automa temperature compensa and turbulence technology, it easily adapts to environmental changes.

Design

Features

3

1

2

1. LED indicator2. Detection window3. Bracket

PCB Layout

Alarm zone setupTamper switch*

Infrared sensor**

AA 1.5V LR6

Antenna

LED working indicator

*Tamper switchWhen the alarm system is armed, the tamper switch will trigger the alarm if the case isopened.

**Infrared sensorDetects the infrared rays released by humanbody Do not touch the surface. Keepthe surface clean.

LED

Blinks self Blinks once: an intruder is detectedBlinks twice: self is complete; entering working mode.Blinks once every 3 seconds: under-voltage indica the eries must be replaced. (You will be informed by SMS when the eries are low if the detector is registered in the control panel.)

The PIR motion detector is a high performance wireless motion detector boasting a digital dual-core fuzzy logic infrared control chip with intelligent analysis. This technology identifies interferences created by body motion and reduces the false alarm rate.

Page 9: Shield 200 EasyProtect Kit - English Manual

1716

Usage

Open the case and remove the strip. will start for 30 seconds.

When the sensor is in operation, if it is triggered more than twice within 3 minutes, it will switch to standby mode to save power. If no movement is detected within the next 3 minutes, the sensor goes back to working mode.

Connect

Register in the control panel

Press the at the back of the control panel to enter the mode. Press the connect at the back of the sensor or trigger the sensor (by moving in front of it).

Avoid the detector close to windows, air , heater, refrigerator, oven, sunshine and places where the temperature changes fast or where the air stream s frequently.

If two detectors are installed in the same det scope, adjust the loca to avoid interferences and false alarms.

Fix the bracket on the wall with screws and ach the detector to the bracket. Adjust the bracket to change the det distance and angle. It is recommended to mount the detector 2m from the ground.

Top

Ground

2.2 m

The detector is more sensitive to cross movements than vertical movements.

Side viewTop view

A. the inst turn the detector on. one minute of self-t press the test walk in the scope of det and watch the LED indicator to make sure the detector

is working.

B. The LED indicator blinks once when body movement is detected.

C. Adjust the detector angle to achieve the best de performance.

Power supplyDC 3V (AA 1.5V LR6 Ba x 2)

St current≤ 30uA

Alarm current≤ 15 mA

De scope8m / 110°

T distance≤ 80m (in open area)

Radio-frequency 433 MHz (±75 KHz)

Housing materialABS plas

cTemparature: -10°C~55°CR humidity: ≤ 80% (non-condensing)

Detector dimensions (L x W x H)107 x 53 x 32 mm

Bracket dimensions (L x W x H)52 x 30 x 26.5 mm

Scope

110°

Top view

0m 2m 4m 6m 8m2m

0m

Side view

Page 10: Shield 200 EasyProtect Kit - English Manual

1918

Wireless Door / Window Contact

Features

signals to the control panel when the

Thanks to the tamper switch, any t to remove the cover of the Door / Window Contact will trigger the alarm.

Design

Magnet

Transmitter

LED indicator

PCB Layout

LED working indicator

Zone setting

AAA 1.5V Battery

AAA 1.5V Battery x 1

Tamper switch

LED

Blinks once: the door or window is open and the sends a signal to the control panel.Blinks quickly: Low power indica the eries must be replaced.

Register the detector in the alarm system

Press the at the back of the control panel to enter the mode. Then separate the magnet from the er.

To check if the registr is complete, arm the system and separate the magnet from the again by opening the door or window on which it is installed. If the siren rings out,

the regis is successful.

- Open the case and remove the ery strip.- Mount the sensor on the door and the magnet on the

door frame.- Make sure the magnet is placed above the er.- Mount the magnet max. 1 cm away from the

and secure the and magnet with double-sided tape or screws.

- Avoid the sensor in areas with a large amount of metal or electrical wiring such as a furnace or room.

Power supply

current≤ 30 uA

Alarm current≤ 15 mA

Tr distance≤80 m (in open area)

Radio-frequency 433 MHz (±75 KHz)

Housing materialABS

Oper temperature-10°C~55°C

humidity≤80% (non-condensing)

T dimensions (LxWxH)60 x 45 x 18 mm

Magnet dimensions (LxWxH)45 x 19 x 17,5 mm

The door/window contact can be installed on doors, windows, and any other objucts that open and close. The sensor sends signals to the control panel when the magnet is separated from the

Page 11: Shield 200 EasyProtect Kit - English Manual

20 21

This keyboard enables you to arm and disarm your alarm system, or arm it in Home Mode.

27

Page 12: Shield 200 EasyProtect Kit - English Manual

22 23

It

Page 13: Shield 200 EasyProtect Kit - English Manual

24 25

The MS-10A operates under 4modes

Page 14: Shield 200 EasyProtect Kit - English Manual

26 27

Maxsmart

Maxsmart

MaxsmartMaxsmart

It

.

Page 15: Shield 200 EasyProtect Kit - English Manual

28 29

Page 16: Shield 200 EasyProtect Kit - English Manual

30 31

Page 17: Shield 200 EasyProtect Kit - English Manual

32 33

Maxsmart

Page 18: Shield 200 EasyProtect Kit - English Manual

34 35

Page 19: Shield 200 EasyProtect Kit - English Manual

36 37

Page 20: Shield 200 EasyProtect Kit - English Manual

38 39

VIEWONHOME This product bears the selective sorting symbol for waste electrical and electronic equipment(WEEE).This means that this product must be handled pursuant to European.Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment.For further information,please contact your local or regional authorities.Electronic products not included in the selective sorting process are potentially dangerous for the environment and human heath due to the presence of hazardous substances. In compliance with European law. This product was designed and manufactured in compliance with Directive 2002/95/EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS Directive - Rohs) and is deemed to comply with the maximum concentration values set by the European Technical Adaptation Committee(TAC).Made in CHINA

Standard

Local language user manuals can be downloaded from www.viewonhome.eu or by scanning this QR code

Page 21: Shield 200 EasyProtect Kit - English Manual