Model Number
Input MBHThermal
%
Gross Output MBH
Net Rating MBH
Turn-down A B C D E F G H J K L M N O P Q R Gas
Conn.
WaterAir
IntakeVent Size
Oper. Weight(with
water)
Ship. Weight(lbs.)Min Max Inlet/
Outlet
FB*0751 50 750 96.2% 722 627 15:1 78” 30” 55-1/2” 57-5/8” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 55” 51” 13” 8-3/4” 26-3/4” 23-3/4” 49-1/2” 7-3/8” 1-1/4” 3” 6” 6” 1,768 1,560FB*1001 50 1,000 96.2% 962 837 20:1 78” 30” 56-1/2” 57-5/8” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 56” 51” 13” 8-3/4” 26-3/4” 23-1/8” 49-1/2” 6-1/2” 1-1/4” 3” 6” 6” 1,838 1,596FB*1251 63 1,250 96.2% 1,203 1,046 20:1 78” 30” 56-1/2” 57-3/4” 66-1/8” 11-7/8” 11-3/8” 11-1/4” 12-1/2” 56” 51-3/8” 13” 8-3/4” 26-3/4” 21-5/8” 49-1/2” 6-1/2” 1-1/4” 3” 6” 8” 1,975 1,648FB*1501 60 1,500 96.2% 1,443 1,255 25:1 78” 30” 67-3/4” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 67-1/4” 62-3/8” 15-7/8” 9” 26-7/8” 27-7/8” 59-1/4” 5-1/8” 1-1/2” 4” 8” 8” 2,307 1,961FB*1751 70 1,750 96.2% 1,684 1,464 25:1 78” 30” 66-1/4” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 65-3/4” 61-1/2” 15-7/8” 9” 27” 27-1/8” 58-3/4” 5-1/8” 1-1/2” 4” 8” 8” 2,458 2,017FB*2001 80 1,999 96.2% 1,924 1,673 25:1 78” 30” 66-1/2” 68” 65-3/8” 12-3/8” 11-3/8” 11-1/4” 12-1/2” 66” 61-1/2” 15-7/8” 9” 27” 26-3/4” 58-3/4” 5-1/8” 1-1/2” 4” 8” 8” 2,570 2,087FB*2501 125 2,500 96% 2,400 2,087 20:1 77-3/4” 35” 83-3/4” 83-3/4” 63-3/4” 13-1/2” 11-1/4” 10-1/2” 12-1/4” 83-1/4” 76-1/4” 19-3/4” 9-1/4” 28-3/4” 32” 71” 7-1/4” 2” 4” 8” 9” 3,600 2,577FB*3001 150 3,000 96% 2,880 2,504 20:1 77-3/4” 35” 83-3/4” 83-3/4” 63-3/4” 13-1/2” 11-1/4” 10-1/2” 12-1/4” 83-1/4” 76-1/4” 19-3/4” 9-1/4” 28-3/4” 32” 71” 7-1/4” 2” 4” 10” 10” 3,900 2,881FB*3501 175 3,500 96% 3,360 2,921 20:1 77-3/4” 42” 91-1/2” 86-3/4” 63-1/2” 13-1/4” 11-1/2” 10-3/4” 12-1/2” 91” 82” 20-1/4” 12-3/4” 35-1/2” 31-3/4” 73-1/4” 8-3/4” 2” 4” 10” 10” 4,600 3,218FB*4001 333 3,999 96% 3,840 3,339 12:1 77-3/4” 45-1/2” 103-1/2” 99” 63-1/2” 13-3/4” 11-1/2” 10-3/4” 12-1/2” 103” 94” 24-3/4” 13-1/2” 39-1/2” 42-1/4” 85-1/4” 10-1/2” 2-1/2” 4” 12” 12” 5,200 3,805FB*5001 500 4,999 96% 4,800 4,173 10:1 77-3/4” 46-1/2” 102-1/4” 99-1/2” 63-1/2” 15” 11-1/2” 10-3/4” 12-1/2” 101-3/4” 92-1/2” 22” 14” 39-3/4” 39-1/2” 84” 9” 2-1/2” 6” 12” 14” 5,900 4,101FB*6001 600 6,000 96% 5,760 5,008 10:1 77-3/4” 50” 102-3/4” 99-3/4” 63-1/4” 14-3/4” 11-1/2” 10-3/4” 12-1/2” 102-1/2” 93-1/4” 20” 15-3/4” 43-1/2” 36-1/2” 83-3/4” 9-1/4” 2-1/2” 6” 14” 14” 6,900 4,711
MODELSFB 0751 - FB 6001
CRESTCOMMERCIAL
CONDENSING BOILERSubmittal Sheet FBN-Sub-09
JOB NOTES:
CD
H
J
A
G
F
E
B
KL
R
NO
PM
Q
Job Name: Location:
_______________________________________________ _______________________________________________
Engineer: Model #:
_______________________________________________ _______________________________________________
Contractor: Type Gas:
_______________________________________________ _______________________________________________
Agent/Wholesaler: Equipment Tag(s):
_______________________________________________ _______________________________________________
SIDE BACK TOP
Notes:* Insert “N” for natural gas, “L” for LP gas models and
“D” for dual fuel.• Indoor installation only. Information subject to
change without notice. • Low NOx Operation.• Lochinvar should be consulted before selecting a boiler
for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
• The ratings have been determined under the provisions governing forced draft burners.
• The Net AHRI water ratings shown are based on a piping and pickup allowance of 1.15.
Smart Touch™ FeaturesCON·X·US Remote Connect
SMART TOUCH Touchscreen Operating Control
Full-Color 8” Touchscreen LCD Display
Built-in Cascading Sequencer for up to 8 Boilers> Built-in Redundancy> Cascade Multiple Sized Boilers> Lead/Lag Cascade> Efficiency Optimized Cascade
Front-End Loading Capability with Copper-Fin II® and Power-Fin® Boilers
Building Management System Integration with 0-10 VDC Input
BACnet MSTP Communications
Modbus Communication
Outdoor Reset Control with Outdoor Air Sensor
Password Security
Domestic Hot Water Prioritization> DHW tank piped with priority in the boiler loop> DHW tank piped as a zone in the system with the
pumps controlled by the Smart System> DHW Modulation Limiting> Separately Adjustable SH/DHW Switching Times
Low Water Flow Safety Control & Indication
Inlet & Outlet Temperature Readout
Freeze Protection
Service Reminder
Time Clock
Data Logging> Hours Running, Space Heating> Hours Running, Domestic Hot Water> Hours Running, Modulation Rate> Ignition Attempts> Last 10 Lockouts
Programmable System Efficiency Optimizers> Night Setback> Anti-Cycling> Outdoor Air Reset Curve> Ramp Delay> Boost Temperature & Time> Modulation Factor Control
Three Pump Control> System Pump> Boiler Pump> Domestic Hot Water Pump
6/18—Printed in U.S.A.
Lochinvar, LLC 300 Maddox Simpson ParkwayLebanon, Tennessee 37090P: 615.889.8900 / F: 615.547.1000
Lochinvar.com
Codes & RegistrationsASME certified, “H” Stamp / National Board
California Code Compliant
Canadian Registration Number (CRN)
CSD1 / Factory Mutual / GE Gap Compliant
South Coast Air Quality Management District Qualified (FB 0751-2001)
High-Voltage Terminal Strip> 120 VAC / 60 Hertz / 1 Phase Power Supply(FB 0751-2001)
> 208 VAC/ 60 Hertz/ 3 Phase Power Supply(FB 2501-3501)
> 480 VAC/60 Hertz/3 Phase Power Supply(FB 4001-6001)
> System Pump, Boiler Pump and DHW Pump Power
Low-Voltage Terminal Strip> 24 VAC Auxiliary Device Relay> Auxiliary Proving Switch Contacts> Alarm on Any Failure Contacts> Runtime Contacts> DHW Thermostat Contacts> Unit Enable/Disable Contacts> System Sensor Contacts> DHW Tank Sensor Contacts> Outdoor Air Sensor Contacts> Cascade Contacts> 0-10 VDC BMS External Control Contact> 0-10 VDC Variable Speed Boiler Pump Control Contact
Standard FeaturesUp to 96.2% Thermal Efficiency
Proof of Closure Valve (FB 6001)
Modulating Burner with up to 25:1 Turndown
Direct-Spark Ignition
Low NOx Operation
Sealed Combustion
Air Inlet Filter
Low Gas Pressure Operation
Vertical and Horizontal Direct Venting > Direct Vent up to 100 Feet> PVC, CPVC, Polypropylene or AL29-4C
(FB 0751-3501)> AL29-4C (FB 0751-6001)
ASME “H” Stamped Heat Exchanger
316L Stainless Steel Fire Tubes
160 psi Working Pressure
On/Off Switch
Adjustable High Limit with Manual Reset
Low Water Cutoff with Manual Reset & Test
High & Low Gas Pressure Switches w/Manual Reset
Low Air Pressure Switches
Condensate Trap w/Blocked Drain Switch
Drain Valve
System Sensor
Outdoor Air Sensor
Inlet & Outlet Temperature Sensors
High-Voltage Terminal Strip
Low-Voltage Terminal Strip
Downstream Gas Test Cocks
50 psi ASME Relief Valve
Temperature & Pressure Gauge
Zero Clearances to Combustible Materials
High Altitude Models Available
10-Year Limited Warranty (See Warranty for Details)
1-Year Warranty on Parts (See Warranty for Details)
Optional EquipmentAlarm Bell
BMS Gateway - BACnet IP or LonWorks
Condensate Neutralization Kit
Common Vent Kits Damper
Motorized Isolation Valve
Variable Speed Boiler Pump
Wireless Outdoor Temperature Sensor
75 psi ASME Relief Valve
100 psi ASME Relief Valve
125 psi ASME Relief Valve
150 psi ASME Relief Valve
Electrical Options (Shipped Loose):> FB 0751-2001
208V/ 1Ø/60 Hz g 120V/ 1Ø/60Hz
480V/ 1Ø/60 Hz g 120V/ 1Ø/60Hz
600V/ 1Ø/60 Hz g 120V/ 1Ø/60Hz
> FB 2501-3501
480V/ 3Ø/60 Hz g 208V/ 3Ø/60Hz
600V/ 3Ø/60 Hz g 208V/ 3Ø/60Hz
> FB 4001-6001
600V/ 3Ø/60 Hz g 480V/ 3Ø/60Hz