    SIGMACHECKHANDHELDEDDYCURRENTCONDUCTIVITYMETER

    USERMANUAL

    DocNo:50024:Issue2

  • 7/30/2019 SigmaCheck User Manual_02

    2/26

    2

    TableofContents

    1 Introduction...................................................................................................3 1.1 AbouttheSigmaCheck.....................................................................................................................3

    1.2 Abbreviations.......................................................................................................................................3

    1.3 Keys..........................................................................................................................................................41.4 Connectors............................................................................................................................................4

    2 StandardPackageandaccessories..................................................................52.1 StandardPackage...............................................................................................................................5

    2.2 RecommendedAccessories...........................................................................................................6

    2.3 OptionalAccessories.........................................................................................................................6

    3 Operationoftheinstrument...........................................................................73.1 Appearance...........................................................................................................................................7

    3.2 Operationprinciple...........................................................................................................................7

    3.3 Screenlayout........................................................................................................................................7

    3.4 MenuScreen/Structure.................................................................................................................7

    3.5 ReadingsScreen..................................................................................................................................8

    3.5.1 Freeze................. .......... .......... .......... .......... .......... ......... .......... .......... .......... .......... .......... ......... .......... .....9

    3.6 Home/InstrumentStatusScreen..............................................................................................9

    3.7 Setup.....................................................................................................................................................10

    3.7.1 Calibration.........................................................................................................................................10

    3.7.2 Frequency...........................................................................................................................................10

    3.7.3 Probe.....................................................................................................................................................11

    3.7.4 Advanced.......... .......... ......... .......... .......... .......... .......... .......... ......... .......... .......... .......... .......... .......... ...11

    3.7.5 Configure.......... .......... ......... .......... .......... .......... .......... .......... ......... .......... .......... .......... .......... .......... ...14

    4 Charging.......................................................................................................18

    5 UsingwithaPC.............................................................................................185.1 ConnectingtoPC..............................................................................................................................18

    5.1.1 SigmaCheckPC..................................................................................................................................18

    5.1.2 ETherFUU(FirmwareUpdateUtility)...................................................................................21

    5.2 Usingaspreadsheettoanalysedata......................................................................................23

    6 Setting-upprocedures..................................................................................24 6.1 Calibratingandmakingareading............................................................................................24

    6.2 Usingthe2ddataloggingfunction..........................................................................................24

    6.3 ALARMsetup.....................................................................................................................................25

    7 CareandMaintenance..................................................................................25

    8 TroubleShooting..........................................................................................25

    9 TransportationandStorage..........................................................................25

    10 Specifications............................................................................................26

  • 7/30/2019 SigmaCheck User Manual_02

    3/26

    3

    1 Introduction1.1 AbouttheSIGMACHECK

    TheSIGMACHECKisdesignedtobeextremelyeasytousemakingitsuitableforuseby

    shopfloorinspectorstoengineers.

    TheSIGMACHECKmeetstherequirementsforconductivitymeasurementsinthe

    aircraftmanufacturingandmaintenancefieldswhereconductivitymeasurements

    areusedtoverifyproperalloy/temperordetectheatdamagedcomponents.The

    SIGMACHECKisalsousefultodeterminethepurityofpreciousmetals(counterfeit

    detection)suchasgoldbullionandcoins.

    TheSIGMACHECKhasalarge,colour,LCDdisplaythatiseasilyseeninalllighting

    conditions

    TheSIGMACHECKisdesignedforconvenientsinglehandedoperationduetoits

    sculptedhousinganditsconvenientsizeandweight;onlyofapound(350g.)and

    measuringlessthan6tallx3widex1thick(163x80x25mm).Aremovable,

    siliconerubberbootisincludedtoprotecttheinstrumentinroughenvironments.

    ThestandardProbehasbeendesignedtocomfortablyfitthehandoftheuser.

    TheSIGMACHECKhasastandardoperatingfrequencyof60kHzandauxiliary

    frequenciesof:120,240,480and960kHzcanbeselectedwhennecessaryfortesting

    thinmaterialswiththestandardprobe.

    OtherfeaturesoftheETHERNDESIGMACHECKinclude:

    FieldExchangeableProbesviaSDCard TrueUSBPCConnectivityforremotecontrolanddatalogging. TheUSBConnectionallowseasychargingoftheInstrumentwithouthaving

    toswapthebatteries.

    TheSIGMACHECKissuppliedwithaflameretardantABScase,adual(Hi-Low)

    calibrationblock,probecable,charger,USBlead,removabledeskstandanduser

    manual.Optional,smalldiameterprobewillbeoffered.

    1.2 Abbreviations

    C Centigrade

    F Fahrenheit

    IACS InternationalAnnealedCopperStandard

    MicroSD MicroSecureDigitalFlashMemoryCard

    Mil Thousandthsofaninch(0.001)US

    MS/m MegaSiemenspermetre

    Thou Thousandthsofaninch(0.001)UK

  • 7/30/2019 SigmaCheck User Manual_02

    4/26

    4

    1.3 Keys

    TheSIGMACHECKinstrumenthas7keys.4arrowkeys(Up,Down,Left,Right),anOK

    key(shownwithatick),aBackorCancelkey(shownwithacurlyarrow)andaPower

    key.

    Up

    OK

    Left Right

    Down

    1.4 Connectors

    Thereare2ConnectorsontheSIGMACHECK

    AMini-BUSBconnectorisontheleft.Thisisusedfor:

    a) Chargingtheinstrumentifrechargeablebatteriesareinstalled.b) PoweringtheInstrument.c) ConnectingtheinstrumenttoaPCfordataupordownload.

    Back/CancelPower

    A5pinLemoconnectorisontherighthadsidefor

    connectingprobes

  • 7/30/2019 SigmaCheck User Manual_02

    5/26

    5

    2 StandardPackageandaccessories2.1 StandardPackage

    AllofthefollowingAccessoriesshouldbeavailablebeforeusingtheSIGMACHECK

    instrument,althoughlimitedoperationcanbeperformedwithout.

    NotpicturedisamainsconnectortowhichtheUSBcablecanbeconnectedtoifnot

    connectedtoaPCforchargingand/oroperation.

    DualsampleCalibrationBlock

    MicroSDmemorycard

    SigmaCheck

    USBcable

    Probe

    Quantity PartNo Description

    1 ISIG001 SIGMACHECKInstrument

    1 ASIG001 DualconductivitystandardwithCuandStainless

    Steel

    1 ASIG002 Adjustableinstrumentstand

    1 40222 SiliconeRubberBoot1 ALL05-L05-012-SIG ProbeCable

    1 PSIG001 Probe13mmdia.60-480kHz

    2 30239 2xErgonomicProbeSkirtsfortubes&easyProbe

    handling

    1 A090 USBCableforPCconnection/Charging

    1 A092 UniversalUSBChargerAC100-240VAC

    1 A089 MicroSDCard

    1 40293 QuickReferenceGuide

    1 60005 ManualandUtilityonUSBstick

    1 AC001 SoftCarryingCase

  • 7/30/2019 SigmaCheck User Manual_02

    6/26

    6

    2.2 RecommendedAccessories

    PartNo Description

    ASIG004 PeliHardCasewithcustominsert.

    ALL05-L05-012-SIG ProbeCable

    PSIG001 Probe13mmdia.60-480kHz

    2.3 OptionalAccessories

    PartNo Description

    PSIG002 7mmProbe240-960kHz

    PSIG001R RightAngle13mmprobe60-480kHz

    PSIG002R RightAngle7mmprobe240-960kHz

    ASIG004 PeliHardCasewithcustominsert.ATBC-COPPER Accessory,TestBlock,Conductivity,Copper,(100.0-103.6%IACS)

    ATBC-ALU1200

    Accessory,TestBlock,Conductivity,AluminiumAlloy,1200-H4,(58.5-60.0

    %IACS)

    ATBC-ALU6082

    Accessory,TestBlock,Conductivity,AluminiumAlloy,6082-T6(44.0-48.0

    %IACS)

    ATBC-ALU6061

    Accessory,TestBlock,Conductivity,AluminiumAlloy,6061-T4(42.3-43.8

    %IACS)

    ATBC-ALU2014A-T6

    Accessory,TestBlock,Conductivity,AluminiumAlloy,2014A-T6(38.0-42.0

    %IACS)

    ATBC-ALU2014A-T4

    Accessory,TestBlock,Conductivity,AluminiumAlloy,2014A-T4(34.0-37.0

    %IACS)

    ATBC-ALU7075

    Accessory,TestBlock,Conductivity,AluminiumAlloy,7075-T6(31.4-34.8

    %IACS)

    ATBC-ALU5083Accessory,TestBlock,Conductivity,AluminiumAlloy,5083(27.5-28.5%IACS)

    ATBC-BRASS Accessory,TestBlock,Conductivity,Brass,CZ121(24.0-26.0%IACS)

    ATBC-PBRONZE Accessory,TestBlock,Conductivity,PhosphorBronze(17.0-22.0%IACS)

    ATBC-NICSILVER Accessory,TestBlock,Conductivity,NickelSilver,LC1291(8.5-9.5%IACS)

    ATBC-STST303S Accessory,TestBlock,Conductivity,StainlessSteel,303S(2.0-3.0%IACS)

    ATBC-TITANIUM Accessory,TestBlock,Conductivity,Titanium,6AL-4V(1.0-2.2%IACS)

    ASIG003 5Testblockholder.

    AC001 SoftCarryingCase

  • 7/30/2019 SigmaCheck User Manual_02

    7/26

    7

    3 Operationoftheinstrument3.1 Appearance3.2 Operationprinciple

    TheSIGMACHECKisasimpletouseConductivityMeterwithLift-Offcapability.

    TheSIGMACHECKcontainsmanymodernfeatures,forexampleaMicroSDcardis

    includedintheinstrumentsothatlargeamountsofdatacanbestored.AUSB

    connectorispresentsothattheinstrumentcancommunicateinreal-timewiththe

    PCsoftware.

    Onceconfigured,theSIGMACHECKcanveryquicklybepickedup,turnedon,calibrated

    andthenaccurateandfastmeasurementscanbetakenofConductivityorLift-Off.

    3.3 ScreenlayoutTheinstrumenthas2mainscreenlayouts,themenuscreenandthereadingsscreen.

    TheMenuscreenallowsallaspectsoftheinstrumenttobeconfigured,fromthe

    inspectiondetailstotheindividualuserspreference.TheReadingsscreenhas2

    panes,atopandabottom.

    3.4 MenuScreen/Structure

    ThemenusystemontheSIGMACHECKisdesignedalongthe

    linesofthefolder/filelayoutpresentonmanymodern

    computers.Ifamenuitemcontainschildmenuitems

    beneathit,itwillhaveaplus(+)symbolafterit,meaning

    thatitcanbeexpandedtorevealmoremenuitems.Ifa

    menuitemhasaminus(-)afteritstitlethenitschildmenu

    itemsarealreadyvisible.ThisscreenshotshowstheTop

    levelSIGMACHECKmenuwithits4submenus.Advancedand

    Configurecontainmoresubmenus,hencetheir+.

    TheUpandDownkeysmoreupanddownchildmenuitems

    arethecurrentlevel.TomoveupaleveltheLeftorBack

    keysshouldbeused.Toenteramenuitemssubitems,the

    RightorOKkeysareused.

  • 7/30/2019 SigmaCheck User Manual_02

    8/26

    8

    3.5 ReadingsScreen

    SelectingthetoplevelSIGMACHECKmenuitemchangestheinstrumentintoReadings

    Mode.Herethescreenhas2configurablepanesandastatusbar.PressingtheUpor

    Downkeystogglestheselectedpane,thisisvisiblebythetitleofthepanebeing

    highlighted.PressingtheLeftorRightkeyschangesthedisplayoftheselectedpane

    throughthefollowingpossibilities:

    LiftOff

    Conductivity

    LiftOffBarGraph

    ConductivityMeter

    Time&Date

    MetalSort

    TheLowerPanecanalsobeOFF,whichexpandstheUpperPane.IfDataLoggingis

    enabledthentheLowerpanewillONLYshowDataLogginguntilitisdisabled.

    Examplesofthesevariousdisplaymodesareshownhere:

    WiththeLowerPanesettoOFF.ExamplesofLift-Offbargraph,ConductivityMeter

    andConductivity:

  • 7/30/2019 SigmaCheck User Manual_02

    9/26

    9

    TheStatusBarshows4AlarmLEDrepresentations,thetemperaturereadbythe

    probe,aMicroSDcardiconandaBatteryMeterorUSBindicator.

    Seethe3.7.4.1Alarmssectionbelowforanexplanationoftheirfunctionality.The

    temperaturecanbedisplayedinCelsiusorFahrenheitdependingontheUnits

    setting;seethe3.7.5.3Unitssectionbelow.TheMicroSDiconwillbewithorwithout

    aredcross.Withoutaredcrossindicatesthatthecardispresentandfunctioning

    correctly,withtheredcross,thereisafailureofthecard.Thebatterystatesare

    Empty,25%,50%75%,FullorUSBConnected.

    or

    3.5.1 FreezeWheninReadingsmodepressingtheOKkeywillfreezethecurrentdisplay.Any

    alarmsthatwereflashingwillremainilluminated.PressingOKagainwillremovethe

    freezeandthereal-timereadingswillcontinue.Pressinganyotherkeywillalso

    cancelthefreezeandthekeywillbeactioned.

    TheFreezefunctionalitycannotbeusedwheninDataLoggingmode(asOKlogsa

    reading)oriftheinstrumenthasnotbeencalibratedsincethelastpower-on(asOK

    movestheSIGMACHECKtothecalibrationmenu).

    PleasenotethattheFreezefunctionalityfreezesthedisplayonlyandNOTanyrealtimedatabeingoutputtedovertheUSB.

    Toidentifywhenthescreenisfrozen,thescreentitletextofSIGMACHECKwill

    changecolour.

    3.6 Home/InstrumentStatusScreen

    TheHomescreenshows3usefulpiecesofinformation,thecurrentProbefilethatis

    loadedin,thecurrentFrequencythatisbeingusedandwhentheinstrumentshould

    nextbecalibrated.

  • 7/30/2019 SigmaCheck User Manual_02

    10/26

    10

    TheselectedProbeshouldbethesameaswhatisactuallyconnectedtothe

    instrument.Ifthesedifferthenthereisnoguaranteethatanyvaluesdisplayedwill

    beaccurate.IfNoprobeInfoisdisplayed,thenaProbeneedstobeselectedfrom

    theprobemenu,see3.7.3below.

    Thefrequencyisdependentonwhatisrequiredfortheinspectionandwhatthe

    probehasbeencalibratedtododuringmanufacture.

    TheAnnualCalDuedateisthedatebywhichtheinstrumentandprobeshouldbe

    re-calibrated.Thisdatewillflashonceithaspassed.Theinstrumentwillcontinueto

    functionbutthereisnoguaranteethatanyvaluesdisplayedwillbeaccurate.

    3.7 Setup

    AllaspectsoftheSIGMACHECKcanbeconfiguredusingthemenus.Navigationofthe

    menusystemisexplainedabovein3.4MenuScreen/Structure.

    3.7.1 Calibration

    Calibrationshouldbecarriedeachtimetheinstrumentisturnedon

    andperiodicallythereafter.Thecalibrationprocedureisexplained

    below,see6.1Calibratingandmakingareading.

    Tocalibratetheinstrument,theCalibrationBlocks(CB1andCB2)

    valuesMUSTbesettothevaluesoftheblocksattachedtothetopof

    theinstrument.TochangeavalueuseUporDowntohighlightthe

    desiredCalibrationBlock.UseLeftorRighttobegineditingthevalue.

    LeftandRightwillchangethecurrentlyeditingcharacterandUpand

    Downwillcyclebetween0and9.MovingLeftfromthemost

    significantdigitwilladdanewdigituptoamaximumof3significant

    figures.MovingRightfromasignificantfigureof0willremoveit.

    Whenthevalueiscorrect,presstheOKbuttontosaveit,orBackto

    canceleditingandreturnthevaluetoitsoriginalvalue.

    SelectingthemenuoptionCalibratewillbeginthecalibrationprocedure.

    PressOKorBacktoleavethismenu.

    3.7.2 Frequency

    Onenteringthismenuallavailablefrequenciesforthecurrently

    loadedprobewillbelisted.Thecurrentfrequencywillbehighlighted.

    Acrossafterthefrequencyindicatesthatthereisaproblemwiththe

    probedetailsatthatfrequencystoredontheMicroSDcard.Atick

    indicatesalliswellandthefrequencymaybeselected.

    Left/UporRight/Downwillmoveupanddownthelistofavailable

    frequencies.PressOKtoselectafrequencyorBacktoleavethe

    currentselectedfrequency.

  • 7/30/2019 SigmaCheck User Manual_02

    11/26

    11

    3.7.3 Probe

    Onenteringtheprobemenuthecurrentselectedprobewillbeshown.UpandDown

    cyclethroughtheheadingsofS/N(SerialNumber),freq(frequency)andanynotes

    thatarepresent.

    MovingLeftorRightontheS/Nwillcyclethroughallavailableprobe

    filesontheinstrumentandupdatetherestofthescreenwiththe

    detailsofthatprobefile.

    MovingLeftorRightonthefreqheadingwillmoveupanddownthe

    availablefrequenciesforthisprobefile.PressingOKwhileafrequency

    ishighlightedwillloadtheprobefileandconfiguretheinstrumentto

    usethatfrequency.PressingOKwithnofrequencyhighlightedwill

    loadintheprobefileandusethefirstfrequencyinthelist.

    MovingLeftorRightwiththeNoteshighlightedwillscrollthenotesin

    thecasethattherearemorecharactersthanfitontothescreen.PressingBackwillleavetheinstrumentwiththecurrentprobefileand

    atthecurrentfrequency.

    3.7.4 Advanced

    3.7.4.1 Alarms

    AvisualalarmcanbeconfiguredtotriggerwhenaConductivityorLift-Offexceedsor

    dropsbelowapredeterminedvalue.Whenanalarmistriggeredandthevalueis

    visibleonthereadingsscreenthereadingwillflashbetweentheValueandAlarm

    colours(see3.7.5.2Colourbelow).InthealarmstatethecorrespondingLEDonthe

    statusbarwillflash.TheLEDrelatestothevaluesbeingshownontheUpperorLowerpanesinthereadingsscreen.

    ThefirstLEDindicatesthattheUpperPanevaluehasexceededitshighalarmtrigger

    value.

  • 7/30/2019 SigmaCheck User Manual_02

    12/26

    12

    ThesecondLEDindicatesthattheUpperPanevaluehasdroppedbelowitslow

    alarmtriggervalue.

    ThethirdLEDindicatesthattheLowerPanevaluehasexceededitshighalarmtrigger

    value.

    TheforthLEDindicatesthattheUpperPanevaluehasdroppedbelowitslowalarm

    triggervalue.

    TheabovediagramillustratestheUpperpanevalueexceedingitshighalarmvalue

    whiletheLowerpanevaluehasdroppedbelowitslowalarmvalue.

    WhenenteringtheAlarmmenu,fouralarmsareshownusingthe

    unitsspecifiedintheUnitsmenu.AHighandLowvaluefor

    ConductivityandThicknessisavailable.

    TochangeavalueuseUporDowntohighlightthedesiredAlarm.

    UseLeftorRighttobegineditingthevalue.LeftandRightwillchange

    thecurrentlyeditingcharacterandUpandDownwillcyclebetween0and9.MovingLeftfromthemostsignificantdigitwilladdanew

    digituptoamaximumof3significantfigures.MovingRightfroma

    significantfigureof0willremoveit.

    Whenthevalueiscorrect,presstheOKbuttontosaveit,orBackto

    canceleditingandreturnthevaluetoitsoriginalvalue.

    PressOKorBacktoleavethismenu.

    3.7.4.2 MetalSortTheMetalSortfunctionalityallows10differentrangesofConductivitytobeentered.

    Ifconductivityisencounteredthatfitswithinoneoftheserangesthetextassociated

    withthatrangewillbedisplayedontheMetalSortpane.

    Thismenuitemallowstherangetobeentered(alowandhigh

    conductivityvalue)andanamethatwillbeshown.Theunitsof

    conductivitywilldependontheUnitsmenuitem.

    UsingtheUpandDownkeys,thehighlightedoptionwillgofrom

    NametoLowvaluetoHighvalueandthentothenextmetal,andso

    onuptothe10thmetal.PressingOKwillbegineditingofthe

    highlightedvalueorname,pressingOKagainwillsavethenew

    name/valuewhilstpressingBackwillcanceleditingandreturnthe

    name/valuetoitsoriginalvalue.Fordetailsoneditingvalues,see

    3.7.4.1Alarmsabove.Editingofcharactersissimilar.LeftandRight

    changethecharacterbeingeditedandUpandDowncyclethrough

    theavailablecharacterslikeso:

    0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz

    **Pleasenote,forametaltobeshownonthereadingspane,theMetalSortpane

    mustbepresentontheUpperorLowerpane.**

  • 7/30/2019 SigmaCheck User Manual_02

    13/26

    13

    WhenallchangeshavebeenmadepressOKorBacktoreturntotheAdvanced

    menu.

    3.7.4.3 DataLoggingTheDataLoggingfunctionality,whenenabled,allowsConductivity

    readingstobeloggedatthepressoftheOKbutton.Thereare2

    locationstostoreDataLoggingdata,MemoryCardorRAM.The

    differencesare:

    RAM

    Thenumberofreadingsislimitedtoabout8000(Rowsmultipliedby

    Columns).

    Oncepowerisremovedthereadingsarelost.

    SigmaCheckPCcancontinuetooperatefully.DataLoggingdatacanbeextractedatanypointusing

    SigmaCheckPC.

    UsingtheLeftorRightkeys,previousdatacanbeoverwritten.

    MemoryCard

    WhileDataLoggingisenabled,anycardaccesswillstopdatalogging.

    DatacannotbeuploadeduntilDataLogginghascompletedorbeenstopped.

    Onceavaluehasbeenlogged,itcannotbechanged.

    ManyseparatedataLoggingsessionscantakeplaceandalldataissaved.

    ThesereadingsarestoredintheSIGMACHECKsmemoryuntiltheyareuploadedtoaPCviatheUSBcableandthePCSoftwarepackage.Theresultingfileisdesignedto

    bereadablebymostSpreadsheetpackages,hencewhyontheDataLoggingmenua

    numberofRowsandColumnsareshown.Whenenabled,theDataLoggingpaneis

    shownintheLowerpaneofthereadingsscreen.ItshowsthecurrentColumn&Row

    numbersandbelowthat,thelastconductivityvaluethatwaslogged.Whenall

    ColumnsandRowsarefull,thescreenwillshowLoggingFull.Ifavaluehasbeen

    takenincorrectlythepressingLeftorRightwillmovebackorforwardsbetween

    readingsallowinganewreadingtobetakenandoverwritetheexistingvalue.When

    movingbackwardsandforwards,thepreviousreadingatthislocationwillnotbe

    shown.

    Ifasimplelistofvaluesisallthatisrequired,thensimplysetthe

    RowsorColumnsto1andtheothervaluetotherequirednumberof

    readings.ThetotalnumberofreadingstakenwillalwaysbetheRows

    multipliedbytheColumns.Aseachreadingistaken,theSIGMACHECK

    incrementstheColumnfirst,thenwhentherowisfull,theRowis

    incremented.Thereforetheresultingspreadsheetwillhavethefirst

    readinginthetopleftcornerthenreadinglikeabooklefttoright,

    toptobottom.

    ForinformationondownloadingtheDataLoggerdata,see5.1

    ConnectingtoaPCbelow.

  • 7/30/2019 SigmaCheck User Manual_02

    14/26

    14

    OntheDataLoggingmenu,theUpandDownkeyswillchangethehighlighted

    heading.LeftorRightkeyswillbegineditingoftheRows/ColumnsortoggletheData

    Loggingenabledoption.Foreditingofthevaluessee3.7.4.1Alarmsabove.

    Pleasenote,ifDataLoggingisenabledhere,thelowerpaneonthereadingsscreen

    willONLYshowDataLogging.

    3.7.4.4 MemoryCard

    TheSIGMACHECKcontainsaslotforaMicroSDmemorycard.Correct

    functioningoftheinstrumentrequiresacardtobefitted(the

    instrumentissuppliedwithacard).Thefilesandfolderstructureof

    thecardcanbeseenusingthismenuitem.

    OnselectingMemorythecontentsofthecardareshown.Foldersareshownwithalloftheircontentsindented.FoldersareintheText

    colour,filesintheValuecolour(see3.7.5.2Colourabove).

    Iftherearemorefiles/foldersthanfitontothescreen(evidentby

    theverticallinetotheleftgoingoffofthebottomofthescreen)

    thenpressingthedownkeywillscrolltheview.

    IftheOKkeyispressedwhileafileishighlightedtheFileDetails

    screenisshown.Itshowsthefilenamealongwithitscompletepath.

    Thefilesize(-1ifthefileisinfactadirectory).Thereisthen2

    options,DeleteandUpload.Deletewillpermantelydeletethefile.

    UploadwillsendthefiletoSigmaCheckPCiftheSIGMACHECKis

    connectedtoaPCviatheUSBandSigmaCheckPCisconnectedtothe

    SIGMACHECK.Whenthefiletransferisinitiatedaprogressbarwillbe

    shownonSigmaCheckPCmainscreen.Whencomplete,aSaveFile

    windowwillopenonthePC.

    PressBacktoreturntotheAdvancedmenu.

    3.7.5Configure

    TheConfiguremenucontainsthefollowingsub-menus:

    Brightness Colour Units Precision Powersave Time&date

  • 7/30/2019 SigmaCheck User Manual_02

    15/26

    15

    3.7.5.1 Brightness

    Thebrightnessmenuallowsthebrightnessofthescreentobe

    changed.Loweringthebrightnesswillextendthebatterylifeofthe

    SIGMACHECK.

    PressingLeftorDownwilldecreasethebrightnessby10%

    PressingUporRightwillincreasethebrightnessby10%.

    PressingOKwillsavethecurrentbrightnesslevel.

    PressingBackwillreturnthebrightnesslevelbacktoitsprevious

    value.

    3.7.5.2 Colour

    4Coloursmaybechanged.

    TheText,Background,ValueandAlarms.Thetextcolouristhecolourmostoftenusedformenuitemsandheadingsonthereadingsscreen.Thebackgroundcolouris

    self-explanatory.TheValuecolouriswhatisusedforthenumbersonthereadings

    screenandseveralmenuitems,theAlarmcolourshouldbenoticeablydifferentto

    thevaluecolourthatisusedtoindicatethatavalueisinthealarmstate.Thecolours

    usedforthemajorityofthescreenshotsinthismanualshowninthefirstscreen

    shot.Theothersarepopularalternatives.

    PressingUporDowncyclesbetweentheheadings.PressingLeftorRightcycles

    throughtheavailablecolourswhichare:

    BLACK,WHITE,RED,GREEN,YELLOW,BLUE,CYAN,GREY,PINK,CREAM

    PressingOKwillsaveandusethecurrentcolourscheme.PressingBackwillgoback

    tothepreviouscolourscheme.Itispossibletosetthetextandbackgroundcolours

    tothesamecolourwhilecyclingthroughthecoloursbutitISNOTpossibletoaccept

    thesecolourstobethesame.

  • 7/30/2019 SigmaCheck User Manual_02

    16/26

    16

    3.7.5.3 Units

    Theunitscanbesettoanyofthefollowing:

    Conductivity-%IACSorMS/m

    TemperaturedegreesCelsiusorFahrenheit

    Length(Lift-Off)mm,Thouormil

    (Thou&mil=Thousandthsofaninch).

    TheUpandDownkeyscyclebetweentheheadings,LeftandRight

    toggletheUnitsforthatheading.

    PressOKtoacceptthenewunitsorBacktoreturntothe

    Configuremenuandleavetheunitsunaffected.

    Theunitsselectedhereaffectallplaceswherethevaluesare

    displayedontheinstrument,includingothermenus(i.e.Alarms).

    TheunitswhendownloadingtothePCorviewingontheSIGMACHECK

    PCSoftwareisfixedto:Conductivity-%IACS

    TemperaturedegreesCelsius

    Lengthmm

    3.7.5.4 Precision

    ThePrecisiononlyaffectshowmanydecimalplacesareshownonthescreenofthe

    SIGMACHECK.TheConductivitycanhave0,1,2,3orAutodecimalplaces.

    Temperature,0or1decimalplacesandLength0,1or2decimalplaces.Autochangestheprecisionofconductivityreadingsdependingonthevalue:

    0to10%IACS=3decimalplaces.

    10to100%IACS=2decimalplaces.

    100andabove%IACS=1decimnalplace.

    PressingtheUporDownkeyscyclesthroughtheheadings.

    PressingLeftdecreasesthenumberofdecimalplacesand

    pressingRightincreasesthenumber.

    Thenumberbeloweachheadingisarepresentationofanumber

    displayedtothecurrentnumberofdecimalplaces.

    PressOKtoacceptthenewnumberofdecimalplacesandreturn

    totheconfiguremenuorBacktoreturntothemenukeepingthe

    previousnumberofdecimalplaces.

  • 7/30/2019 SigmaCheck User Manual_02

    17/26

    17

    3.7.5.5 PowerSave

    Thereare2methodsofsavingpower.Theinstrumentcanbeset

    toautomaticallydimthescreenafterasettimeperiodand/or

    turnofftheinstrumentcompletelyafterasettimeperiod.These

    timeperiodsrangeformOff(disabled)to60minutesin5minute

    steps.

    PressingtheUporDownkeyscyclesbetweentheheadings.

    PressingtheLeftkeydecreasesthetimeinstepsof5from60to

    Off.

    PressingtheRightkeyincreasesthetimeinstepsof5fromOffto

    60.

    PressOKtousethenewvaluesorBacktousethepreviousvalues.

    3.7.5.6 Time&Date

    TheSIGMACHECKcontainsarealtimeclock.Itenablesthetimeand

    datetobeviewedonapaneintheReadingsscreenandisalso

    requiredforwritingdatatotheMicroSDcard.Thedateandtime

    caneasilybesetandwillberememberedevenwhenthereareno

    batteriesorUSBpower.

    PressingLeftorRightcyclesbetweenthefields:

    Day->Month->Year->Hour->Minute->Second.PressingUporDownwillincrementordecrementthehighlighted

    value,exceptforsecondswhereUporDownwillsetthenumber

    ofSecondsto0.

    Whenfinished,pressingOKwillsetthetimeoftheSIGMACHECKtowhathasbeen

    entered.PressingBackwillleavetheTime&dateunchanged.

    3.7.5.7 Language

    ThemajorityofthetextdisplayedbytheSIGMACHECKistranslatedintoseveral

    differentlanguages.OnthelanguagemenupressingtheLeftorRightkeyscycles

    throughthecurrentlyavailablelanguages.

    PressOKtoacceptthenewlanguageorBacktoreturntotheConfiguremenuand

    returnthelanguagetothepreviousone.

  • 7/30/2019 SigmaCheck User Manual_02

    18/26

    18

    4 Charging

    TheSIGMACHECKmayeitherbechargedusingthesuppliedACcharger.Alternatively

    usingtheUSBcabletheunitmaybechargedfroastandardPCUSBconnector.Note

    whilsttheunitispowereduptheUSBchargerwillpowertheinstrumentbutchargingofthebatterieswillnotoccuruntiltheunitispowereddown.

    AstheinstrumentusesAAbatteriesthennonrechargeablebatteriesmaybeused.

    Thesewillnotbechargedasthereisprotectioncircuitrytopreventthis.

    5 UsingwithaPC5.1 ConnectingtoPC

    TheSIGMACHECKconnectstoaPCviaitsminiUSB-Bconnector.Thisconnectionprovidesallcommunicationsandchargingfunctionality.

    Thereare2PCapplicationsthatusethisUSBconnection:

    SigmaCheckPCandtheETherFUU(EtherFirmwareUpdateUtility)software

    packages.

    WhenaSIGMACHECKisfirstconnectedtoaPCtherequireddriverswillautomatically

    beinstalled.SIGMACHECKusesWindowsdefaultdriverssonoadditionaldriversare

    required.

    5.1.1 SigmaCheckPC

    Thisapplicationhasseveraluseswhenconnectedtoa

    SIGMACHECK:

    Displayreal-timevaluesofConductivity,Lift-OffandTemperature

    DisplaytheUniqueID(nottheserialnumber)oftheSIGMACHECK.

    FilehandlingoftheSIGMACHECKsmicroSDcard. UploadDataLoggerfilesfromtheSIGMACHECK. RemotecontroltheSIGMACHECK.

    Upto4SIGMACHECKscanbesimultaneouslyconnected,butonly

    onecanbeusedatatimebySigmaCheckPC.Theactiveunitcan

    quicklyandeasilybechangedbetweenanyofthefourbyaclick

    ofoneofthenumberedbuttonsalongthetopofthescreen.

  • 7/30/2019 SigmaCheck User Manual_02

    19/26

    19

    5.1.1.1 Real-Timedisplay

    AssoonastheSIGMACHECKispowered,connectedtoSigmaCheckPCandthe

    instrumentsplashscreenacknowledged,real-timevalueswillbedisplayedonthe

    SigmaCheckPCscreen.AcrossthetopofthedisplayistheUniqueIDofthe

    instrument,followedbyEtherNDEandSIGMACHECK.

    Inlargertextbelowthatistheconductivity.Inlargetextinthelowerhalfofthe

    screenistheLift-Off.

    Acrossthebottomisthecurrentprobetemperature.

    Acrossthemiddleisatextentryboxandaprogressbar.

    Unlikeontheinstrument,theunitsherecannotbechangedandaresetto:

    Conductivity -%IACS Temperature -degreesCelsius Liftoff-mm5.1.1.2 RemoteControl

    AssoonastheSIGMACHECKisconnectedandtheUniqueIDdisplayed,itcanbe

    controlledfromSigmaCheckPC.The7buttonsvisibleonthePCScreen(Up,Down,

    Left,Right,OK,Power,Back),whenclickedhavethesameeffectontheinstrument

    aspressingthephysicalbuttonsbyhand.PleasenotethatiftheSIGMACHECKisbeing

    operatedcompletelyremotelythenabuttonmustbepressedaftertheUniqueIDis

    showntoremovetheSIGMACHECKsplashScreen.Untilthisbuttonispressednoreal-

    timedataisreceived.

    ThePowerbuttonwillturntheremoteSIGMACHECKOFFbutwillnotturnONa

    SIGMACHECK.

    5.1.1.3 Uploading&Downloadingfilesto/fromaSIGMACHECK

    Thereare2waysofgettingfilesonandofftheSIGMACHECKsMicroSDcard:

    1. Removethecardfromtheinstrument(aslotispresentundertheCalibrationBlocks),placeintoaPCcardreaderandcopythefilesusingstandard

    Windows/Maccapabilities.

    2. ConnectingtheSIGMACHECKtoaPCusingthesuppliedUSBcablethenusingtheSigmaCheckPCfilehandlingfunctionalityviatheMicroSDCardbutton

    (seebelow).

  • 7/30/2019 SigmaCheck User Manual_02

    20/26

    20

    5.1.1.3.1 SigmaCheckPCFilehandling

    ConnecttheSigmaChecktoaPCusingtheUSBcable.WithSigmaCheckPCrunning

    andconnectedtotheinstrument,clickontheMicroSDCardbuttonacrossthe

    bottom.Awindowwillappearlikeso:

    ThetopofthefiletreeshowsFileSystem.EverythingbelowthisiseitherafileorfolderthatispresentontheSIGMACHECKsMicroSDCard.Foldersthathaveany

    contentsareshownwithasmallboxtotheleftoftheirfoldericon.Clickingonthis

    boxtogglesitbetweenexpandedornotexpanded.

    Ifafileordirectoryisselected,the3buttonsacrossthebottomareenabledandcan

    beclicked.Theirfunctionalityisasfollows:

    DeleteFileThehighlightedfilewillbedeleted.Directoriescannotbedeleted.

    GetFileThehighlightedfilewillbedownloadedfromtheSIGMACHECK.Aprogress

    barwillbeshownacrossthemainscreenofSigmaCheckPCtoshowtheprogressof

    thisfiledownload.Oncecomplete,aSaveFilewindowwillappearandthefilecanbe

    savedanywhereonthePC.SendFileAnOpenFilewindowwillappearandafilecanbeselectedfromthePC.

    ClickingOpenwillsendthisfiletothedirectoryhighlighted(orifafileishighlighted,

    toitsdirectory)ontheSIGMACHECK.TheprogressbarontheSigmaCheckPCmain

    screenwillshowprogressofthisfiletransfer.

    AfterDeletingorsendingafile,thescreenwillberefreshedshowingthenewstate

    ofthefilesystemontheSIGMACHECKsMicroSDCard.

  • 7/30/2019 SigmaCheck User Manual_02

    21/26

    21

    Directoriescannotbecreatedordeleted.Thedirectorystructureisusedbythe

    SIGMACHECKlikeso:

    ProbesAllprobefilesmustresideinhere.

    SettingsAllfilesrelatedtotheconfigurationoftheinstrumentmustresidehere.

    DataLogAnyfilescreatedbytheDataLoggingfunctionality(assumingitis

    configuredtowriteitsdatatothecardandnottoRAM)arewrittenhere.The

    filenameiscreatedfromtheTime&Datethatthefilewascreatedinthefollowing

    format:

    YYYYMMDDHHMMSS.xml,

    ie20120119103502=10:35am(and2seconds)onthe19thJan,2012.

    Ifdownloadinganewprobefiletouse,pleaserememberthatitmustbeselected

    fromtheProbesmenuontheinstrumentafterthedownload!

    IfanyDataLoggingtotheMicroSdcardwasinprogresswhenclickingthe

    SigmaCheckPCbuttonMicroSDCard,itwillbeterminated.Thedatawillnotbelost

    andthefilewillbeclosedsafely.

    5.1.1.4 DownloadingDataLoggerDatafromRAM.

    DataLoggingcanbeconfiguredtoeithersavetoRAM(internalSIGMACHECKmemory)

    ortooutputtotheMicroSDCard.

    Thebenefitsofthetwoapproachesaredescribedinsection3.7.4.3.

    ClickingtheRetrieveDatabuttonalongthebottomoftheSigmaCheckPCscreen

    willbegintheuploadprocess.AslongastheSIGMACHECKisconnectedto

    SigmaCheckPCthisprocesscanbeinitiated.EvenifdataLogginghasnotbeenstarted,datarelatingtothenumberofColumnsandRowswillbeuploaded.IfData

    Loggingwasnotcompleted,theremainingreadingswillbeinanunknownstateand

    willnotcontainvaliddata.

    AftertheRetrieveDatabuttonispressed,datawillbeginuploading.Theprogress

    bardoesnotfunctionforfileupload.Thetimetheuploadtakesisdependentonthe

    numberofRowsandColumnsthatDataLoggingissettoo.WhenUploadiscomplete

    afilesavewindowwillopen.SelectafilenameandlocationwheretosavetheXML

    file.Forviewingthefile,see5.2UsingaSpreadsheettoanalysedatabelow.

    5.1.2 ETherFUU(FirmwareUpdateUtility)

    TheSIGMACHECKinstrumentfirmwarecanbeupdatedbythecustomerinthefield

    allowingthemtotakeadvantageofnewfeaturesandimprovementsastheyare

    releasedfromETHERNDE.TheprocessissimpleandrequirestheETherFUUsoftware

    tobeinstalledonaPC,theMini-BUSBcableandofcoursetheSIGMACHECK

    instrument.

    AnupdatefilewillbeprovidedbyETHERNDE,thisfilewillbeaDFUfile(i.e.

    v_1_1_0.dfu).RuntheETherFUUsoftware.Thescreenwillbeasso:

  • 7/30/2019 SigmaCheck User Manual_02

    22/26

    22

    First,theSIGMACHECKmustbeputintoFirmwareLoadermode.Todothis:

    1. TurntheinstrumentOFF.2. HolddowntheDownkey.3. PressthePowerkey.4. WhentheSplashScreenisvisible,releasetheDownkey.5. TheSplashScreenwillshowEtherNDE,FirmwareLoader

    WhentheSIGMACHECKisinFirmwareLoadermode,ETherFUUrunningonthePCand

    theSIGMACHECKisconnectedtothePC,theSplashScreenwillshowUsbConnected

    andETherFUUwillshow:

    ConnectedtoEtherFirmwareLoader,butNOfileloaded.

    Now,clicktheChoosebuttononETherFUUandusetheOpenfilewindowto

    navigateandselecttheprovided*.dfufile.ETherFUUwillnowshow:

    Filecorrectlyloadedandconnected

    TheUpgradebuttonwillnolongerbegreyedoutandshouldbeclicked.The

    softwarewillbedownloadedandprogresswillbeshownbytheprogressbar.

    Whencompleted,theSIGMACHECKmustberestarted.CheckontheSplashscreenof

    theSIGMACHECKthatthenewsoftwareversionisdisplayed.

  • 7/30/2019 SigmaCheck User Manual_02

    23/26

    23

    5.2 Usingaspreadsheettoanalysedata

    DataLoggerdatathathasbeendownloadedviaSigmaCheckPCwillhavebeensaved

    ontothePCina*.xmlfile(See5.1.1.3Uploading&Downloadingfiles&5.1.1.4

    DownloadingDataLoggingDatafromRAM,above).

    ThisfileformatisnotautomaticallyrecognisedbyWindowsasbeingaspreadsheet

    file,sodonotopenthefilefromitsicon.Openaspreadsheetpackage,clickOpen

    File,navigatetothefileandopenit.Thespreadsheetpackageshouldrecognisethe

    fileformatandopenthefileasifitwasaregularSpreadsheetfile.Hereisan

    examplefileopenedupinMSExcel.TheDataLoggerontheSIGMACHECKwas

    configuredtohave2rowsand3columns:

    Thevaluesshownare%IACSvalues.

    Whenclosingthespreadsheetpackagewerecommendsavingthefilenotinthe

    original*.xmlformat,butintheSpreadsheetpackagesdefaultformat.

  • 7/30/2019 SigmaCheck User Manual_02

    24/26

    24

    6 Setting-upprocedures6.1 Calibratingandmakingareading

    TheSIGMACHECKshouldbecalibratedafterpoweronandatregularintervalsto

    ensureaccuracy.Whatfollowsisaquickstep-by-stepguidetoconfiguringthe

    SIGMACHECKandtakingareading.

    SplashScreen

    ReadingsScreen

    MainMenuScreen

    CalibrationScreen

    PressPowerKeyfor2

    seconds.Splashscreen

    appears.Afteracouple

    ofsecondsthereading

    screenisshown.

    Awarnignacrossthe

    bottomreadsPress

    toCalasnocalsince

    power-on.

    PressOKtoCal(goto

    step5)ORpressBACK

    togotothemenu

    screen

    RightorDownkeyto

    accesstheMainMenu.

    Tocalibrate,with

    Calibration

    highlighted,pressOK.

    Setairpoint

    SethighConductivity SetLowConductivity.

    ReadingScreen

    EnsurethattheCB1&

    CB2valuesmatchthe

    blocksontopofthe

    instrument,thenwith

    Calibratehighlighted,pressOK.

    Holdprobeinairat

    least100mm(4)away

    fromanymetalor

    magnets.WaitforBlue

    bartostabilise.PressOK.

    Placeprobeonleft

    calibrationsamplewait

    forbluebartostabilise

    andpressOK

    Placeprobeonright

    calibrationsample

    weightforbluebarto

    stabiliseandpressOK.

    Afterabriefpausetheinstrumentwillreturn

    totheReadingScreen

    andisreadytouse.

    6.2 Usingthe2ddataloggingfunction

    ThecompleteDataLoggingprocessisbrokenupintoseveralparts,eachisexplained

    inprevioussections:

    1. ConfiguringtheSIGMACHECKtoDataLog,seeDataLogging.2. DownloadingtheDataLoggerdatatoaPC,seeDownloadingDataLoggerData

  • 7/30/2019 SigmaCheck User Manual_02

    25/26

    25

    3. Viewingtheresultantfiles,seeUsingaspreadsheettoanalysedata.

    6.3 ALARMsetup

    TheAlarmfunctionalityisfullyexplainedintheAlarmssection.

    7 CareandMaintenance

    Usesoftcleanclothmoistenedwithasoapormilddetergenttocleanthecase,buttonsanddisplaywindow.

    Donotuseanabrasivecleaningagentofanykind,asthiswilldamagetheinstrument.

    Donotusesolventstocleantheinstrument,astheywillcauseirreparabledamagetocaseandcontents.

    8 TroubleShooting9 TransportationandStorage

  • 7/30/2019 SigmaCheck User Manual_02

    26/26

    10Specifications

    InspectionTechnology EddyCurrent

    OperatingFrequencies

    60kHz,120kHz,240kHz,480kHz,960kHz(requiresprobe

    suitablefortestfrequency)Display 240x320pixelscolourdisplay.LCDwithselectablebacklight.

    ConductivityStandards

    DualSampleConductivityReferenceBlocksmountedontop

    ofunit.Removableforvalueverification,andensuring

    thermalequilibrium.

    ConductivityRange 0.5%IACSto120%IACS,0.28-70MS/m

    Resolution

    Selectableas1,2or3decimalplacesuptoamaximumof5

    digitse.g.0.050-120.00

    LiftOff

    12.7mmprobecompensatedto0.030(0.7mm)7mmprobe

    compensatedto0.015(0.35mm)

    AbsoluteAccuracy

    At20C.+/-0.5%ofreadingpluserrorinreference

    standard.Probeinthermalequilibriumwithmetal.

    Temperature

    Measurement In-probesensor(accurateto0.5C)Range0Cto+50C

    AutomaticCompensation Conductivitymeasurementsarecorrectedtothe20Cvalue.

    EnvironmentalRange

    0to95%relativehumidity,0Cto+50Cforreliable

    operation

    DataLoggerMemory

    Removable2GBmicroSDCardallowingmanythousandsof

    probemapstobestoredandeasilytransferredbetween

    instruments.

    Probes

    12.7mmdiameterfor60kHz-480kHz.Probesare

    interchangeablewithsimpleoperatorresettingprocedure.

    Probesarefieldexchangeableanddonotrequirethereturn

    tomanufacturerforcalibration.

    PCConnectivity USBportforchargerandPCcommunications

    Accessories

    SettingsReferenceBlocks-Arangeofconductivityreferences

    standardstraceabletoUSandEuropeanstandardsare

    availableforin-fielduse.Uptofivecanbemountedonan

    aluminiumanodisedholdingplate.

    Size 163mmLongx80mmWidex25mmDeep

    Construction&Storage

    Highimpact,splashproof,mouldedUL94-5VAflame

    retardantABScase.Protectiverubberboottoholdunit,

    probes,probecable,operatormanualonUSB,and

    removablestand.

    Weight 350g(12oz.)includingbatteries

    Power

    Providedwith2x1.5VAANickelMetalHydrideBatteries,

    Approx.upto6hrs.life.