SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 1 de DiagnosticDP.ppt
PROCES S FIELD BUS
SIMATICSystem diagnosis
Totally Integrated Automation
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 2 de DiagnosticDP.ppt
PROCES S FIELD BUS
CPU diagnosis bufferCPU diagnosis bufferCPU diagnosis buffer
Display system errorsDisplay system errors
Online diagnosis in HW ConfigOnline diagnosis in HW Config
Display new diagnosis buffer entries on PG
Visualization of a Profibus system
Display new diagnosis buffer entries on PG
On the PG
On the HMI system
Visualization of a Profibus system
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 3 de DiagnosticDP.ppt
PROCES S FIELD BUS
Rapport automatique des événements systèmesRapport automatique des événements systèmes
Diagnostic système avec SIMATIC S7/Win AC Tampon de diagnostic des CPU S7
Différenciation apparition / disparition d‘erreurDifférenciation apparition / disparition d‘erreur
Horodatage des événements (Date / Heure)Horodatage des événements (Date / Heure)
Information détaillée en clairInformation détaillée en clair
Evénements définis par l‘utilisateurEvénements définis par l‘utilisateur
Lecture du tampon de diagnostic avec le logiciel STEP7Lecture du tampon de diagnostic avec le logiciel STEP7
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 4 de DiagnosticDP.ppt
PROCES S FIELD BUS
CPU
DI DO
FM
PS
OS
DP slave
User program
AI AO
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 5 de DiagnosticDP.ppt
PROCES S FIELD BUS
CPU diagnosis bufferCPU diagnosis buffer
Online diagnosis in HW ConfigOnline diagnosis in HW Config
Display system errors
Visualization of a Profibus system
On the PG
On the HMI System
Display new diagnosis buffer entries on PG
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 6 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic système avec SIMATIC S7 STEP7 / Diagnostic du matériel
Diagnostic d‘ensemble avec mini-icônesDiagnostic d‘ensemble avec mini-icônes
Diagnostic détaillé en clair pour emplacement, N° de voie, erreur de voie
Diagnostic détaillé en clair pour emplacement, N° de voie, erreur de voie
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 7 de DiagnosticDP.ppt
PROCES S FIELD BUS
Display new diagnosis buffer entries on PGDisplay new diagnosis buffer entries on PG
Online diagnosis in HW ConfigOnline diagnosis in HW Config
Display system errors
Visualization of a Profibus system
On the PG
On the HMI system
CPU diagnosis buffer
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 8 de DiagnosticDP.ppt
PROCES S FIELD BUS
- Line breakage© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 9 de DiagnosticDP.ppt
PROCES S FIELD BUS
Display system errorsDisplay system errors
Display new diagnosis buffer entries on PGDisplay new diagnosis buffer entries on PG
On the HMI system
Online diagnosis in HW Config
On the PGCPU diagnosis buffer
Visualization of a Profibus system
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 10 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic système avec SIMATIC S7 STEP7 / Rapport des erreurs système
Définition des messages dans STEP7
Définition des messages dans STEP7
Base de données commune à STEP7 et ProTool Pro
Base de données commune à STEP7 et ProTool Pro
Génération automatique des blocs S7 et appel dans le programme utilisateur
Génération automatique des blocs S7 et appel dans le programme utilisateur
Génération et envoi automatique des messages
Génération et envoi automatique des messages
STEP7 V5.1STEP7 V5.1
Système HMISystème HMI
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 11 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic système avec SIMATIC S7 STEP7 / Rapport des erreurs système
Les erreurs système sont rapportées automatiquement de l‘automate vers l‘HMILes erreurs système sont rapportées automatiquement de l‘automate vers l‘HMI
PROFIBUS
HMI
SPS
Esclave
PG
PC
Diagnostic esclave
Diagnostic esclave
Evénement envoyé automatiquement comme
message vers l‘ HMI
Evénement envoyé automatiquement comme
message vers l‘ HMI
Données S7
Données S7
Error-Info
Donées HMIDonées HMI
Affichage automatique du
message d‘erreur
Affichage automatique du
message d‘erreur
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 12 de DiagnosticDP.ppt
PROCES S FIELD BUS
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 13 de DiagnosticDP.ppt
PROCES S FIELD BUS
Visualization of a Profibus systemVisualization of a Profibus system
Display system errors
On the HMI system
Display new diagnosis buffer entries on PG
Online diagnosis in HW Config
On the PGCPU diagnosis buffer
Display system errors
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 14 de DiagnosticDP.ppt
PROCES S FIELD BUS
DB125
OB82 OB86
FB125 FB125
OB1
FB125
Basic data
Detailed data
ProTool Pro
Win CC
Diagnosis images
© Siemens AG 2001
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 15 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic sysème avec SIMATIC S7Package de diagnostic - Vue d‘ensemble
Codage couleur des InfosCodage couleur des Infos
Usage simple par boutons idéogrammes
Usage simple par boutons idéogrammes
Actualisation automatiqueActualisation automatique
Trois langues français, allemand, anglais
Trois langues français, allemand, anglais
Images modifiables individuellementImages modifiables individuellement
Passage de la vue d‘ensemble à la vue détaillée
Passage de la vue d‘ensemble à la vue détaillée
Vue détaillée Reset RetourSysteme
maître
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 16 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic sysème avec SIMATIC S7Package de diagnostic - Vue détaillée
Affichage de tous les défauts de l‘appareil en mode pas-à-pas
Affichage de tous les défauts de l‘appareil en mode pas-à-pas
Affichage de tous les esclaves en défaut en mode pas-à-pas
Affichage de tous les esclaves en défaut en mode pas-à-pas
Défaut de voie en texte clairenv. 500 messages prédefinis
Défaut de voie en texte clairenv. 500 messages prédefinis
Affichage du type d‘appareil env. 100 esclaves Siemens integrés
Affichage du type d‘appareil env. 100 esclaves Siemens integrés
Actualisation des images par internet
Actualisation des images par internet
Mode manuel Esclave suivant
Erreur suivante
Vue d‘ensemble
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 17 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic sysème avec SIMATIC S7Package de diagnostic - Vue détaillée
Affichage du diagnostic pour un esclave choisi manuellement
Affichage du diagnostic pour un esclave choisi manuellement
Affichage du type de canalDigital/Analogique/FM/CP/DESINA
Affichage du type de canalDigital/Analogique/FM/CP/DESINA
Affichage du nombre de d‘erreurs par esclave
Affichage du nombre de d‘erreurs par esclave
Vue d‘ensemble de bus ASi subordonné
Vue d‘ensemble de bus ASi subordonné
Retour vers la vue d‘ensembleRetour vers la vue d‘ensemble
Mode automatique Vue d‘ensemble
N° d‘esclave
Erreur suivante
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 18 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic sysème avec SIMATIC S7Package de diagnostic
Partie HMI
Esclave N°:
Emplacemen:
Canall N°:
Maître DP:
Erreur Canal:
1
5
4
1
Coupure
Etat: En défaut
FB/DB125
Partie automateInsertion simple dans le programme utilisateur S7Insertion simple dans le programme utilisateur S7
Utilisable pour „plusieurs“ systèmes DPUtilisable pour „plusieurs“ systèmes DP
Utilisable dans S7-300/400:
• CPU 31x-2 DP / CPU 41x-2 DP
• CP 443-5 Ext / IM 467
• SINUMERIK 840D / 840DI
Utilisable dans S7-300/400:
• CPU 31x-2 DP / CPU 41x-2 DP
• CP 443-5 Ext / IM 467
• SINUMERIK 840D / 840DI
Insertion simple dans le système HMIgrâce aux images standard
Insertion simple dans le système HMIgrâce aux images standard
Utilisable dans les systèmes HMI:
• OP7, OP12, OP17, OP27/37, TD27/37, MP270, ProTool-RT
• WIN CC
Utilisable dans les systèmes HMI:
• OP7, OP12, OP17, OP27/37, TD27/37, MP270, ProTool-RT
• WIN CC
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 19 de DiagnosticDP.ppt
PROCES S FIELD BUS
Diagnostic sysème avec SIMATIC S7Package de diagnostic
FC125
Partie automateInsertion simple dans le programme utilisateur S7Insertion simple dans le programme utilisateur S7
Fournit uniquement la liste des stations absentes ou en défaut
Fournit uniquement la liste des stations absentes ou en défaut
Utilisable dans S7-300/400:
• CPU 31x-2 DP / CPU 41x-2 DP
• CP 443-5 Ext / IM 467
• SINUMERIK 840D / 840DI
Utilisable dans S7-300/400:
• CPU 31x-2 DP / CPU 41x-2 DP
• CP 443-5 Ext / IM 467
• SINUMERIK 840D / 840DI
SIMATIC ET 200 Innovations for an Open World © Siemens SAS FranceA&D 11/04/23
B.Bouard Folio 20 de DiagnosticDP.ppt
PROCES S FIELD BUS
Vous pouvez récupérer gratuitement sur le Web les FB125 et FC 125
ainsi que les images toutes faites pour appareils HMI et pour WinCCà l ’adresse suivante
www.siemens.ad.de/simatic-csesous les numéros
387257 pour les FB 125 et FC 1255362473 pour le FB 125 et l ’imagerie pour HMI
6095050 pour le FB 125 et l ’imagerie pour WinCC
MERCI POUR VOTRE ATTENTION