17
Page 1 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712 ABCDEF Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual

Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

  • Upload
    lamphuc

  • View
    219

  • Download
    5

Embed Size (px)

Citation preview

Page 1: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 1 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Simple TOFD / PA Scanner

SSBC 288690

SSBC 288690 FR

Brief User Manual

Page 2: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 2 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Tools Required:

3 mm hex ball Screwdriver

Philips Screwdriver

Page 3: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 3 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

TOFD Probes

Planar Welds

1. Install probes [1] into the Probe-Holders [2] as it is shown on the Fig.1

2. Fit Probe-Holders into the scanner frame with use of long screws [3] on the rail, and fix with nuts [5]

Fig. 1

4 4

1

5

3 3

22

Page 4: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 4 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig.2

7

4 4

6

5

8

5

Page 5: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 5 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

3. Rails [4] and axis of wheel [6] should be adjusted to stay at the scanning surface. Use Joint [7] to adjust the rails and fix them with screw-handle [8] as it is shown on the Fig.2

Fig. 3 4. Ensure that both left & right wheels [9] are installed on the same side of the rail as the Probe-holders as it is

shown on the Fig.3

5. Adjust Joint [11] to set Probe-holders at rectangle to the scanning surface as it is shown on the Fig.3

9

2

2

11

Page 6: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 6 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Circumferential welds

Fig. 4

1. For setting Probe Holders, wheels and rails proceed in the same manner as for flat surface same as for a flat

surface – Fig.4

442 2 9 9

Page 7: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 7 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig.5

2. Adjust Joint [11] to set Probe-holders at rectangle to the scanning surface as it is shown on the Fig.5

22

11

Page 8: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 8 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Longitudinal welds

Fig. 6

7

4 2

4

9

2

Page 9: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 9 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig. 7 1. Install the wheels [9] to stay on the rail at the opposite side rail from the Probe Holders [2], as it is shown on

the Fig.6 and 7

2. Provide probe separation for the TOFD probes according to the inspection procedure and fix probe holders on the rails accordingly

3. Slide wheels at the opposite side of each rail and fix them I oppositely to the corresponding probe

4. Use Joints [7] [11] and to set probes at wheels at rectangle to the scanning surface

2

2

11

9

Page 10: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 10 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

PA Probes

Planar and circumferential welds

Fig. 8

1. Fit PA Probe 12 into Probe Holder 13 and secure it with screw 14 as it is shown on the Fig.8

Fig.9 2. Attach fixture [15] to Probe Holder [13], and secure with screws [16] it is shown on the Fig.9

13

12

14

15

1316

Page 11: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 11 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig.10

99 4 4

13

17

Page 12: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 12 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig. 11

3. Attach Probe-Holder(s) [13] and wheels [9] to the scanner at the opposite sides of the rails, as it on the Fig.

10

4. Secure Probe-holder(s) [13] position with two thumb-screws [17]

5. The PA Probe(s) and wheels should be settled at rectangle to the scanning surface

13

11

9

Page 13: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 13 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig. 12

Page 14: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 14 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig.13 6. Set scanner onto material for the inspection of circumferential welds as it is shown on the Fig.12 and 13.

Distance(s) between PA Probe(s) and weld should be adjusted according to the inspection procedure

Page 15: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 15 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Longitudinal welds

Fig.14

1. Attach fixture [18] to Probe Holder [13], and secure with screws [16] as it is shown on the Fig.14

2. Attach Probe-Holder(s) [13] and wheels [9] to the rail at opposite sides as it is shown on the Fig.15 and 16

Fig. 15 Fig. 16

18

13

16

13

139

9

4 4

Page 16: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 16 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

Fig.17

Fig. 18

4

49

13

7

9

13

11

Page 17: Simple TOFD / PA Scanner - Sonotron NDT · Simple TOFD / PA Scanner SSBC 288690 SSBC 288690 FR Brief User Manual . Page 2 of 17 Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot,

Page 17 of 17

Sonotron NDT

4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0)8-9311000 Fax:++972-(0)8-9477712

ABCDEF

3. Place the scanner onto the scanning surface as it is shown on the Fig.17 and 18

4. Distance(s) between PA Probe(s) and weld should be adjusted according to the inspection procedure,

wheels should be settled at the opposite side of the rail accordingly