DESCRIPTION
Single Cycle Implementation:. Cycle 1. Cycle 2. Clk. lw. sw. Waste. Cycle 1. Cycle 2. Cycle 3. Cycle 4. Cycle 5. Cycle 6. Cycle 7. Cycle 8. Cycle 9. Cycle 10. Clk. lw. sw. R-type. IF. ID. EX. MEM. WB. IF. ID. EX. MEM. IF. Single Cycle vs. Multiple Cycle. - PowerPoint PPT Presentation
Citation preview
CSCI-365Computer Organization
Lecture
Note: Some slides and/or pictures in the following are adapted from: Computer Organization and Design, Patterson & Hennessy, ©2005
Single Cycle vs. Multiple Cycle
Multiple Cycle Implementation:
Clk
Cycle 1
IF ID EX MEM WB
Cycle 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle 8 Cycle 9Cycle 10
IF ID EX MEM
lw sw
IF
R-type
Clk
Single Cycle Implementation:
lw sw Waste
Cycle 1 Cycle 2
General Definitions
• Latency: time to completely execute a certain
task
– E.g., time to read a sector from disk is disk access
time or disk latency
• Throughput: amount of work that can be done
over a period of time
A Pipelined MIPS Processor
• Start the next instruction before the current one has
completed
– improves throughput
– instruction latency is not reduced
– clock cycle (pipeline stage time) limited by slowest stage
– for some instructions, some stages are wasted cycles
Cycle 1 Cycle 2 Cycle 3 Cycle 4 Cycle 5
IF ID EX MEM WBlw
Cycle 7Cycle 6 Cycle 8
sw IF ID EX MEM WB
R-type IF ID EX MEM WB
Single Cycle vs. Multiple Cycle vs. Pipelined
Multiple Cycle Implementation:
Clk
Cycle 1
IF ID EX MEM WB
Cycle 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle 8 Cycle 9Cycle 10
IF ID EX MEM
lw sw
IF
R-type
Clk
Single Cycle Implementation:
lw sw Waste
Cycle 1 Cycle 2
lw IF ID EX MEM WB
Pipeline Implementation:
IF ID EX MEM WBsw
IF ID EX MEM WBR-type
Theoretical Performance
• An ideal pipeline divides a task into k independent sequential
subtasks
– Each subtask requires 1 time unit to complete
– The task itself requires k time units to complete
• For n iterations of task, the execution times:
– With no pipelining: nk time units
– With pipelining: k + (n-1) time units
• Speedup of a k-stage pipeline is
– S = nk / [k+(n-1)] ==> k (for large n)
Simplified MIPS Pipelined Datapath
Can you foresee any problems with these right-to-left flows?
Why are we duplicating some functional units?
Pipeline registers
• Need registers between stages
– To hold information produced in previous cycle
IF
ID
EX for Load
MEM for Load
WB for Load
Wrongregisternumber
There is a BUG here
Corrected Datapath for Load