Removal 1. Insert the control key into the lower keyswitch, turn the
key to the right and hold for approximately 3 seconds until the green LED is lit.
2. Open the alarm door and move the “Enable” switch, located on the circuit board, to the right. (Disabled position)
3. Take a moment to observe the position of the existing siren. The new siren must be installed in the same way.
4. Grasping the connectors, carefully disconnect the siren leads from the wiring harness. Caution, do not pull on the wires as damage to the harness may result.
5. When the two siren leads have been disconnected, remove the two retaining screws holding the siren in place using a Phillips screw driver.
6. Remove the old siren. Be sure to keep the mounting screws and metal spacers, as they will be used in the next step.
Installation
1. Using the existing mounting screws and metal spacers, install the new siren in the same position as the old one.
2. Then, grasping the connectors, carefully reconnect the siren leads to the wiring harness. Important, the RED lead from the siren must be connected to the GREEN harness lead and the BLACK lead from the siren must be connected to the
WHITE harness lead.
3. When the installation is complete, reset and rearm the alarm system.
Connectors
Mounting Screws Internal View
Mounting Screws
Red Siren Lead
to Green
Harness Lead.
1-800-45-ALARM [email protected] www.RestaurantSecurity.com