20
SITE Address Vicinity Map Project Site Kansas City, MO 64153 7701 NW Barry Rd Park Hill High School Park Hill High School Auditorium AV INDEX OF DRAWINGS PHHS-SPC1 Project Specifications 1 PHHS-AV1 Equipment Low Voltage Connection Plan 1 PHHS-AV2 Equipment Low Voltage Connection Plan 2 PHHS-AV3 Equipment Low Voltage Connection Plan 3 PHHS-AV4 Equipment Low Voltage Connection Plan 4 PHHS-AV5 Equipment Low Voltage Connection Plan 5 PHHS-AV6 Equipment Rack Layouts PHHS-AVP1 Equipment Power Connection Plan 1 PHHS-AVP2 Equipment Power Connection Plan 2 PHHS-AVP3 Equipment Power Connection Plan 3 PHHS-AVP4 Equipment Power Connection Plan 4 PHHS-AVP5 Equipment Power Connection Plan 5 PHHS-AVS1 Area Floor Plan - Level 1 PHHS-AVS2 Area Floor Plan - Level 2 PHHS-AVS3 Centerline Section PHHS-AVS4 Enlarged Floor Plans PHHS-AVS5 Enlarged Floor Plans Continued PHHS-AVD1 Elevations And Details

SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

SITE

Address

Vicinity Map

Project Site

Kansas City, MO 64153

7701 NW Barry Rd

Park Hill High School

Park Hill High School Auditorium AV

INDEX OF DRAWINGS

PHHS-SPC1 Project Specifications 1PHHS-AV1 Equipment Low Voltage Connection Plan 1PHHS-AV2 Equipment Low Voltage Connection Plan 2PHHS-AV3 Equipment Low Voltage Connection Plan 3PHHS-AV4 Equipment Low Voltage Connection Plan 4PHHS-AV5 Equipment Low Voltage Connection Plan 5PHHS-AV6 Equipment Rack LayoutsPHHS-AVP1 Equipment Power Connection Plan 1PHHS-AVP2 Equipment Power Connection Plan 2PHHS-AVP3 Equipment Power Connection Plan 3PHHS-AVP4 Equipment Power Connection Plan 4PHHS-AVP5 Equipment Power Connection Plan 5PHHS-AVS1 Area Floor Plan - Level 1PHHS-AVS2 Area Floor Plan - Level 2PHHS-AVS3 Centerline SectionPHHS-AVS4 Enlarged Floor PlansPHHS-AVS5 Enlarged Floor Plans ContinuedPHHS-AVD1 Elevations And Details

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
xxx
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
Cover
AutoCAD SHX Text
Park Hill High School
AutoCAD SHX Text
7701 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64153
Page 2: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Part 1. GENERAL

1.1. SUMMARY

A. The work covered under this Section consists of furnishing all labor,material and services to install a complete audiovisual system as shown onthe Drawings and in these specifications.

B. The Integrator shall do all work which is shown on the Drawings,mentioned in the specifications or reasonably implied as necessary tocomplete the contract for this project.

C. The Integrator is responsible for assessing the conditions of the job site,and facilities for delivering, storing, placing, handling and installing ofmaterials and equipment.

D. The Integrator is responsible for assessing the conditions of the job siteincluding the RF environment for the wireless AV Ethernet network for all AVsystems.

E. Failure to assess the site conditions or failure to examine any and allconstruction documents will in no way relieve the Integrator from therequirement of furnishing all materials and equipment, or performing anywork, that may be required to complete the work in accordance with theConstruction Documents.

F. Neglect of above requirements will not be accepted as reason for delay inthe work or additional compensation.

G. The Scope includes but is not limited to:

1. Equipment and installation labor, including installation of OwnerFurnished Equipment (OFE) as noted on the Drawings, for a fully functionalsystem.

2. Miscellaneous components, hardware, interconnections and terminationsrequired for proper operation of all systems.

3. All components or systems shown on the Drawings, referenced in thesespecifications, or both.

4. Verification of accuracy and completeness of equipment lists, dimensions,mounting details, and equipment compatibility.

5. Accurate documentation of the equipment and installation.

6. One-year warranty of the equipment and installation.

7. Test equipment, tools, ladders, lifts and scaffolding required forinstallation.

8. Daily and final cleanup of debris caused by installation.

9. Assistance during Training.

1.1. BASE SYSTEM DESCRIPTION

A. General

1. This space is designed to allow for presentations from multiple sourcesand locations. Primarily, the space is used for school assemblies, theatricalproductions and instrumental concerts among other things. The Auditoriumhas an audio/video/lighting control area in the rear to allow technician(s) tooperate the A/V/L equipment.

B. Audio:

1. Local speech capture and reinforcement shall be provided by variouswired and wireless microphones covering the entire Auditorium and Atriumareas. Speech shall be locally reinforced with distributed, in-ceilingloudspeakers.

2. An assistive listening system shall be provided to comply with applicablecodes.

3. Program audio reinforcement shall be provided by a Left, Center, Right(LCR) loudspeaker cluster.

C. Video

1. The primary display shall consist of a suspended video projector near thecenter of the Auditorium and an electric projection screen in front of thecurtain (when closed).

2. One permanent computer along with two connection plates shall beprovided as indicated on drawings for presentation connections.

D. Intercom

1. A production intercom system shall be provided at designated locations inthe audio/video/lighting control area.

2. A wireless intercom transmitter with two wireless intercom headsets shallbe integrated into the wired intercom system

E. Controls:

1. A wired touch panel shall be provided backstage and in theaudio/video/lighting control area as indicated on the Drawings.

2. The system shall include various controls and automated functions asdescribed herein.

1.1. REGULATORY REQUIREMENTS

A. All equipment and installations under this contract shall conform to thefollowing:

1. ANSI/NFPA 70 National Electrical Code.

2. ANSI/IEEE C2 National Electrical Safety Code TIA/EIA Standards 568 A(including TSB 67), 569 and 607.

3. IEEE/ANSI 142 1982 Recommended Practice for Grounding of Industrialand Commercial Power Systems.

B. Integrator shall be solely responsible to possess or obtain all permits andcertificates required to complete this project.

C. Integrator and employees shall perform all work in compliance with

current Occupational Safety and Health Administration (OSHA) guidelines andregulations.

1.1. RELATED WORK

A. AV system and control system software.

1. Integrator shall design all graphical user interface design for all AV controltouch panels for the AV systems noted in these specifications and on theDrawings. The Integrator shall review these designs with PHSD for approval.

2. Integrator shall create all customized code for all control systems noted inthese specifications and on the Drawings.

3. Integrator shall load software and configuration files into allprogrammable AV and control system devices.

4. Integrator shall set up and configure all programmable AV and controlsystem devices as directed by PHSD. All source code and graphic files to beprovided to PHSD.

1.1. REFERENCES

A. lnfoComm International; AV Installation Handbook - The Best Practicesfor Quality Audiovisual Systems, copyright 2008.

B. IEEE 802.11G/802.11 B Wireless Site Survey by AMX Corporation: Guidefor Performing a Site Survey:www.amx.com/techsupporl/Applications/Wireless_Site_Survey_GuideAdobe.pdf

1.1. PROJECT/SITE CONDITIONS

A. Coordinate all access to the site at all times with the General Contractorand the Owner.

B. Adhere to the safety standards established by the General Contractor andthe Owner while performing work on site.

C. All employees of the Integrator shall wear identification clearly indicatingthe Integrator's company while on site.

D. Protect all existing work in place by others from damage by theIntegrator, the Integrator's agents/sub Integrators, or any employees, agentsor sub Integrators of the Integrators vendors. The integrator will be solelyresponsible for any/all damage to work in place by others.

E. Keep areas around and inside of each piece of equipment and each rackfree from dust, dirt and debris throughout the project. Equipment that is notproperly maintained during installation shall be replaced at no cost to theOwner before final payment is made to the Integrator.

F. All equipment and materials stored at the Integrators facility(s) or storedand/or installed at the project site will remain the property of the Integratorunless ownership is specifically assumed in writing by the Owner. TheIntegrator shall be solely responsible for the protection of all equipment fromdamage, theft or vandalism regardless of cause, until ownership is specificallyassumed in writing by the Owner or the work described herein is accepted bythe Owner at the time of official turnover.

1.1. REQUIREMENTS SPECIFIC TO THIS PROJECT

A. Integrator Qualifications

1. Warranty service as defined herein shall be performed by the Integrator.

2. The Integrator shall include firm information with the bid including: staffsize, total number of offices, a statement indicating whether or not theIntegrator's primary business is audiovisual system contracting, and astatement of the number of immediate years the Integrator has beenregularly engaged in providing and installing systems of this type and size.

3. The Integrator shall include with the bid resume(s), including years ofexperience, project experience, training and certifications, for proposedproject team members including: project manager, project engineer, leadinstaller, and lead programmer.

4. The Integrator shall include with the bid a list of three to five recentprojects of similar size and scope and include the following information:

a. Project name, address, and description indicative of similarities to thisproject

b. Name of primary contact and telephone number

c. Design consultant (if applicable)

d. Completion date

e. Contract amount

f. Change order amount

g. Project manager, project engineer, lead installer, and lead programmer

h. Indicate whether or not the project was completed on time, and if notexplain why not

1.1. SUBMITTALS

A. Long Lead Time Equipment Submittal:

1. Submit a list of long lead items.

a. These are items that must be ordered before Full Project Submittals aredue to not adversely impact the project schedule.

b. Do not include equipment that will be ordered later.

2. The Integrator shall use reasonable judgment as to which products arelegitimate long lead items.

3. Failure to include an item that may require long lead time shall not relievethe

4. Integrator of the responsibility of furnishing said item to meet the projectschedule.

1.1. WARRANTY

A. Provide warranty repair or replacement for one year on all products

provided by the Integrator (including products having a manufacturer'swarranty of less than one year) and all Integrator workmanship at noadditional cost, except in case of obvious abuse. Consumable items such aslamps, batteries, tapes, etc. are not covered.

Part 2.PRODUCTS

2.1. GENERAL

A. Acceptable Products are listed below and in Appendix G and establish theBasis for Design for the AV systems.

B. Integrator shall be fully responsible for making a substitute product matchthe requirements, description and functionality of the originally specifiedproduct regarding all options, accessories and external interfacerequirements.

C. B-stock, previously installed, refurbished or used equipment shall not beprovided on this project.

D. All products shall be new and under warranty at the time of installation.

E. The Integrator shall provide all options, accessories and hardwarenecessary to meet the function of the design even if they are not specificallylisted (e.g., rack mount kits, separate or additional power supplies, inputmodules, transformers, etc.).

F. Where a specified item has been discontinued by the manufacturerand/or replaced by a new model, PHSD may require submission of the newmodel for evaluation prior to acceptance as a substitute.

G. Product substitution is allowed only by expressed written consent ofPHSD and only before the Bid is received.

2.1. DEVICE PLATES

A. Wall/Floor/Ceiling Mounted Devices

1. NEMA gang type plates shall be standard at each plate location.

2. Plates larger than NEMA 2-gang type plates shall be 1/8" aluminum or1/16" stainless steel.

3. All plates shall be sized to cover the mounting box and rough opening.

4. Finish to be approved by PHSD.

5. Connectors shall be fixed to plates and panels using screws and nuts, orby using the mounting method integral to the connector. Rivets are notacceptable.

6. Detailed drawings of plates panels showing information required inAppendix F shall be submitted prior to fabrication. No exceptions.

7. At all non connectorized pass-throughs provide a secured grommet inceiling, wall or plate.

2.1. FIXED INSTALLATION CABLE

A. General

1. Following are cable types for fixed installation within the base buildingraceway and within fixed AV equipment racks. Unless specifically notedelsewhere, these are NOT acceptable for user interface cables used inlecterns/ credenzas or for connection of portable equipment.

2. Do not exceed cable manufacture's pull-force or bend radiusrecommendations.

3. All cable used on this project shall be rated for plenum use unlessspecified otherwise.

B. Audio or Video (including HDBaseT) over UTP Portable patch cable: Fourpair, solid, #24 AWG, Bonded-Pair, Black.

1. Belden CA21100XXX (“XXX” denotes length)

C. Audio or Video (including HDBaseT) over UTP cable: Four pair, solid, #23AWG, Bonded-Pair, Blue.

1. Belden 10GXS33 D151000

D. AMX or Crestron Control Cable: Two pair - one pair shielded, one pairunshielded. Unshielded pair #18 AWG; shielded pair #22 AWG. NOTE: Alsoacceptable for use within lecterns.

1. Belden 1392P

2. Comparable product by West Penn Wire, Belden, Crestron.

E. Mic or Line Level Signal: Single twisted pair, overall shield, #22 AWG.

1. Belden B6500FE

2. Comparable product by West Penn Wire, Belden, Gepco.

F. Speaker Level: 16/2 UTP with overall jacket.

1. Belden 6200UE

2. Comparable product by West Penn Wire, Belden, Gepco.

G. Speaker Level: 14/2 UTP with overall jacket.

1. Belden 6100UE

2. Comparable product by West Penn Wire, Belden, Gepco.

H. Speaker Level: 12/2 UTP with overall jacket.

1. Belden 6000UE

2. Comparable product by West Penn Wire, Belden, Gepco.

I. Speaker Level: 10/2 UTP with overall jacket.

1. Belden 6T00UP

2. Comparable product by West Penn Wire, Belden, Gepco.

J. Wireless Mic Antenna Coax Cable (less than 75'): RG-58/U

1. Belden 88240

2. Comparable product by West Penn Wire, Canare, Gepco, Commscope.

K. CATV, MATV, or CCTV Trunk Line: RG-11/U Quad Shield

1. Commscope 2287V

L. CATV, MATV, or CCTV Drop Line: RG-6/U Quad Shield

1. Belden 1695A

M. AES3: Single twisted pair, overall shield, #24 AWG, Non-Plenum.

1. Belden 1353A

2. Comparable product by Belden, Canara, Gepco, West Penn Wire,Commscope

N. HD, SDI, and video tie lines: RG-6/U

1. Belden 1695A

2. Comparable product by Liberty, Extron, Canara, Gepco, West Penn Wire,Commscope

O. HDMI Cables 24 AWG, PVC Jacket, Gold Plated Contacts, Mylar/AluminumShielding

1. Extron HDMI Pro Series

2. Comparable product by Kramer, C2G, FSR

P. DisplayPort to HDMI Cables: 30AWG, PVC Jacket, Mylar/AluminumShielding

1. C2G DisplayPort Adapter Cables

2. Comparable products from Kramer, FSR

Q. General Control Cable: Plenum rated, AWG, number of conductors, pairsand/or shield depending on specific control function (e.g., IR, RS 232, dryclosure, etc.).

1. Acceptable manufacturers: Belden, Gepco, West Penn Wire, Commscope,Tappan.

R. Additional cable types as required. Cable type shall be approved by thePHSD prior to use.

2.1. CONNECTORS

A. 1/4 Inch Cable Connectors: Non long frame type.

1. Neutrik "NP" Series

2. Comparable product by Switchcraft.

B. BNC Cable Connectors: 3 piece, true 750 crimp type.

1. Acceptable manufacturers: Kings, Liberty, Extron, Canare, ADC,Trompeter, Cambridge, Belden.

2. Connector shall be compatible with cable type.

C. F Cable Connectors: True 750 crimp type.

1. Acceptable manufacturers: Gilbert, Trompeter, T&B, Belden.

2. Connector shall be compatible with cable type.

D. Loudspeaker Cable Connectors: 4 or 8 pole.

1. Neutrik Speakon NL4FC or NL8FC

2. Comparable product by Switchcraft.

E. XLR Cable Connectors: Number of pins as required.

1. Black shell with gold pins, unless otherwise noted.

2. Neutrik "XX" series

3. No Alternate

F. 1/4 Inch Panel Connectors: All conductors shall be insulated from panel.

1. Neutrik "NJ" series

2. Comparable product by Switchcraft.

G. Recessed BNC Panel Connectors: Shield shall be insulated from panel,shell finish to match adjacent surfaces.

1. Neutrik NBB75DFIB

2. Comparable products by Canare, Switchcraft.

H. Non-recessed BNC Panel Connectors: Shield shall be insulated from panel,shell finish to match adjacent surfaces.

1. Neutrik NBB75FI

2. Comparable product by Canare (with insulating washers) for floor boxes(non-recessed).

I. Recessed F Panel Connectors: Feed thru type, female to female. Shieldshall be insulated from panel.

1. Canare FJ JRU

2. Comparable by Trompeter, ADC.

J. Non-recessed F Panel Connectors: Feed thru type, female to female.Shield shall be insulated from panel.

1. Canare FJ JR

2. Comparable by Trompeter, ADC.

K. Loudspeaker Panel Connectors: 4 or 8 pole.

1. Neutrik Speakon NL4MP or NL8MP

2. Comparable product by Switchcraft

L. RJ 45 Panel Connectors: Recessed Cat 5 or Cat 5e compliant, 8 contacts,Latch hook Retention of RJ45 plugs, 110 Punch down IDC terminals on rear.

1. Belden

2. Comparable product.

M. XLR Panel Connectors: Black shell, gold pins.

1. Neutrik "D" Series

2. Comparable product by Switchcraft.

N. 3.5mm (1/8") Cable Connectors: Mini TRS for balanced mono audio orunbalanced 2 channel audio.

1. Canare F-12

2. Comparable product by Switchcraft, Neutrik, REAN

O. Electrical/Electronic Hardware: Telco 66 type punch blocks are notacceptable. All materials located in plenum spaces must be plenum rated.

1. Terminal barrier strips - provide marker strips

a. Phoenix UK

b. Comparable product by Cinch, Beau

1.1. RACKS AND RACK ACCESSORIES

A. All accessories shall be from the same manufacturer as the rackenclosure.

B. Provide the following accessories for each rack shown on the Drawings.

1. Side panels for each individual rack or for end racks of each group ofracks.

2. Solid or fan top as shown on the Drawings and solid rear door.

3. Grounding stud in top rear of rack.

4. Full height rear mounting rails

5. Full height solid copper bus bar bonded to rack.

6. Horizontal lacing bars (as required).

7. Blank Panels as necessary to close front of rack.

8. Vents, blowers, fans and fan packs as necessary to properly dissipateheat.

9. Power distribution as required and drawn.

Part 3.EXECUTION

3.1. INSTALLATION

A. General

1. All equipment and enclosures described in this specification shall beinstalled plumb and square unless specifically detailed otherwise.

2. All equipment, except that designated as movable, portable or looseequipment, shall be secured and permanently attached to racks or structurein a manner which will require the use of a tool (e.g., screw driver, nutdriver, etc.) for removal.

3. All supports shall meet or exceed the load requirements of the intendedapplication with a minimum safety factor of five.

4. Support hardware shall have SAE Grade 8 load rating (min.).

5. All equipment mounted overhead that has a composite weight, includingmounting hardware and brackets, of forty pounds or more shall be mountedusing plans and specifications approved by a licensed structural engineer. Allfees and expenses related to structural approval shall be paid by theIntegrator.

B. Firmware

1. The Integrator shall install the firmware versions selected by PHSD for allprogrammable or configurable devices.

2. The Integrator shall be responsible for up to two additional firmwarechanges per device until project closeout.

3. Integrator shall notify PHSD prior to any change of firmware in anyprogrammable or configurable device until the Integrator is released fromall installation and warranty responsibilities.

C. Equipment Racks, Conduit, and Raceways

1. Electrical power distribution

a. Provide labels on receptacles within AV racks indicating branch paneland circuit number.

b. See the Drawings for details of power raceway entering and mountinginside rack.

2. Provide a full height, technical ground bus bar in each equipment rack,mount adjacent to the power raceway and electrically bond to rack.

3. Install rack mounted equipment as indicated on the approved AV shopdrawings, and make connections within the racks before delivery to job site.

4. Provide insulated connections between the building electrical racewayand the equipment racks.

5. Provide insulated connections between the AV raceway and theequipment racks.

6. Provide EMT stubs, with insulated bushings to protect cable, into theabove ceiling area for routing cable into the equipment racks.

7. Do not exceed 40% conduit fill.

8.

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-SPC1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 3: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

D. Labeling

1. General

a. Handwritten labels are not acceptable.

b. Do not indicate the Integrator's name on movable, portable or looseequipment, touch panels, cables, or wall plates.

c. Integrator's name may be displayed on rack panel only as shown on thedrawings.

d. Label type, text and graphics shall be approved by PHSD beforefabrication of labeling, plates or other labeled items.

e. All labels shall be legible.

2. Provide permanent, self-adhesive labels on the front panel of rackmounted equipment to indicate system designation/functionality (e.g.,Automixer 3, Press Feed ADA, Speech Amp-Zone A, etc.).

3. Provide permanent, self-adhesive labels on the back of rack mountedequipment.

a. Indicate system designation/functionality.

b. Text shall be identical to equipment front panels.

c. Indicate IP address for all networked equipment located in secured racksor locations.

4. Provide permanent label on plug end of power cords of all rack mountedequipment identifying the power cord with the equipment.

5. Provide labels for front panel input and output buttons of AV routers,switches, mixers, etc.

6. Provide text/graphics engraved directly on receptacle plates, panels, andrack panels.

a. Use eighth inch letters with contrasting fill color.

b. Label all plate mounted connectors and receptacles as shown onapproved shop drawings

c. Label plates with plate designation shown on approved shop drawings.

7. For all installed wiring provide permanent labels using wire numbers ordesignation as shown on approved shop drawings.

a. Wire labels shall be one of the following types

1) Self-adhesive label under clear heat shrink,

2) Direct printed heat shrink

3) Direct printed, self-adhesive, self-laminating

b. Position labels as shown in wiring standard details on the Drawings.

c. Provide wire labels on both ends of cable.

E. Wiring

1. Do not make any in line cable splices unless specifically noted.

2. Use only cable pulling lubricants approved by the cable manufacturer.

3. Provide grommets or chase nipples at cable entry where conduit is notinstalled.

4. Provide cable anchors for any cable or cable bundle larger than 1-inchdiameter, permanently installed and not in conduit. Do not use sticky backcable anchors.

5. Provide a service loop for each cable that connects to equipment in racksor AV furniture. Service loop length shall be sufficient to allow onere-termination without removing cable ties.

6. All cables connecting to a movable lectern, cart, or desk or lectern shall behighly flexible cable, specifically designed by the manufacturer to be flexedrepeatedly. Permanent install type cable is not acceptable for thisapplication.

7. All cable bundles of more than one cable connecting to a movable lectern,cart, or desk or lectern shall be enclosed in a flexible braided sleeve and beof the minimum length extending from the furniture edge as noted on theDrawings.

8. The Integrator shall take precautions to ensure that cabling is not kinked,compressed or otherwise damaged such that performance is compromised.

9. Bend radius shall not be less than recommended by the cablemanufacturer.

10. Do not exceed the maximum permissible pulling tension. Consultthe cable manufacturer for exact data.

11. Use soft Velcro based cable ties located at random distances apartfor installation of specialty cable such as HD-SDI, Category cable, fiber, etc.

F. Service and segregation of installed cables

1. Standard cable segregation - similar signal types or signal levels may begrouped together as approved by PHSD.

a. Microphone: below -30 dBu

b. Line: -30 dBu to +24 dBu

c. Loudspeaker: Greater than +24 dBu

d. Video: 1-volt peak-peak into 75 Ohms

e. Control Circuits: 0-28 Volt into <50k Ohms and Data: 2 Volt peak-peakinto 100 Ohms

f. Fiber

G. Terminations

1. Use crimping tools recommended by the termination manufacturer. Useratcheting crimp tools for spade lugs and Molex pins.

2. Provide insulated spade lugs for screw terminals, two lugs per terminalmaximum.

3. Use properly sized spade lugs for cable gauge and screw size.

4. Conductors in phoenix type connectors shall not be tinned.

5. Terminate conductors with proper mating connectors.

6. Wire Nuts are not acceptable.

7. Audio shield/drain wires shall not be connected to the connector body atany time.

8. Only one cable or set of wires shall be installed into any single connector;do not loop cable in and out of a connector. Provide a terminal block toparallel any audio signal wiring.

9. Dual channel audio circuits using 5 pin XLR type connectors shall be madeusing a dual twisted pair type cable (Canare Star Quad, Proco Ameriquad, orequivalent).

10. If multiple connection types are available on a given piece ofequipment, the screw terminal type (including phoenix type) shall be usedas first choice, with XLR connections used as second choice, and otherconnectors as last choice.

11. Maintain proper polarity when wiring components andloudspeakers.

12. Provide vertically mounted 1/2 inch, painted plywood or1/8-inch-thick blank panels for mounting terminal strips. Do not mountterminal strips on the bottom of racks.

13. Use only true 75 Ohm BNC cable end connectors designed for theintended coaxial cable required. Apply connector with a crimp die certifiedto be used with the intended coaxial cable and BNC. Feed through must alsostrictly maintain 75 Ohms.

14. For HD-SDI, do not use any connectors or feed-throughs notspecifically rated through 3gHz digital bit rate.

15. Bi-directional serial terminations shall always be assumed to be atminimum 5-wire in the absence of approved information which indicatesotherwise.

3.1. QUALITY CONTROL AND INSTALLATION VERIFICATION

A. Full Project Verification

1. All AV systems that are a part of this project shall be completely installedand functional.

2. The Integrator's Project Manager or a senior technician who is familiarwith the system shall demonstrate the complete functionality of each AVsystem to PHSD.

3. PHSD will create a punch list of deficiencies that must be corrected by theIntegrator prior to Final Project Verification.

4. Items added to the punch list during this verification will not bere-verified or removed from the punch list during this verification.

3.1. CONTRACT CLOSEOUT

A. Contract Closeout will be based on completion of Final ProjectVerification, completion of punch list items, acceptance of Project RecordDocuments and Completion of training.

APPENDIX A - DEMARCATION LIST

A. General: This Appendix Describes demarcation points in the Work todetermine where the Integrator's responsibilities end in the specific instancesnoted below.

B. Electrical System Connections: The Integrator shall coordinate with PHSDto extend the AV AC power circuits and insulated ground wires into eachequipment rack.

C. Cabling: All audio, video and control cabling shall be provided, installedand terminated by the Integrator as noted on the Integrator's Constructiondocuments. Voice/data cabling, unless specifically noted otherwise, are theresponsibility of others.

D. Cable Termination: Where cable installation is required, this will includewall and/or floor jacks, plates and terminations at room devices, and serviceloops at patch bay locations.

E. Projector and Monitor Mounts: The Integrator shall install all projectorsand monitor mounts as indicated on the approved shop drawings. Integratorshall verify location and structural suitability before attaching projectors,monitors and mounts.

F. AV Control System Connections and Devices: Integrator shall set upcontrol system equipment with IP Addresses and proprietary control networkaddresses, install all necessary hardware cards, and adjust all appropriate DIPswitch settings, and any other equipment settings such as baud rate andprotocol settings. Integrator shall include all of this information in ProjectRecord Documents.

APPENDIX B - CONTROL SYSTEM REQUIREMENTS

A. General

1. Control system touch panels or button panels shall be programmed bythe AV Integrator. This section shall describe the typical controlprogramming requirements.

2. All requirements herein shall be verified and approved by the Owner priorto commencement of programming.

3. All requirements herein are minimum requirements, full and specificfunctionality shall be coordinated with Owner through the integrationprocess.

4. User interfaces should be task driven, and should use graphics that rely

on shape and text changes in addition to color changes to be usable for thewidest audience.

B. Submittals

1. The Integrator shall include a schedule of milestones for softwareprogramming in the Project Plan submittal.

2. A document describing proposed user interfaces for each system shall besubmitted per the approved Project Plan. The submittal shall include:

a. A user interface overview describing the proposed structure and layoutincluding engraving for keypad controls

b. Annotated screen shots of all proposed touch panel user interface pages

c. A description of proposed system startup and shutdown behaviors andoptions

d. A description of proposed source selection and device control behaviors

e. A description of proposed presentation tools and options

C. User Interface

1. Touch Panels

a. System and device power control as possible

b. Basic source selection of all sources with associated device controls

c. Advanced routing for cameras, press feeds, technician previewmonitors, etc.

D. Functional Requirements

1. Power control of a system is device and system dependent. As a standardwhen the system is turned on, the command to turn on all system devicesshall be given. All devices should be ready for the user once the system isstarted. Some devices have dedicated "On' and "Off' commands while somedevices toggle On/Off using the same command. Minimize the possibility ofsystem start error-due to premature user button presses-by initiating alockout-wherever possible-until the system is fully started. On systemshutdown, all controlled devices, with the exception of the control systemprocessor, shall be powered off or put in a standby state. Power sequencingshall be as per approved shop drawings.

2. Projectors - The projector's input is generally an automatic selectionthrough code as part of the system startup and/ or source selection. Userlevel controls shall be "On", "Off', and "Blank" (Picture Mute). Note: Mostprojectors have a cool-down period on shutdown that is required to protectlamp life. Code shall prevent the projector from being turned back on untilthe cool-down period has been satisfied, and this prevention of normal usercontrol shall be communicated to the user via the user interface.

3. All audio outputs shall be muted on system shutdown. The Owner shalldetermine whether audio levels are reset to default settings/levels onstartup or remain as last left.

a. Program audio (i.e. audio from AV sources such as a laptop, PC, DVD,etc.) shall be controlled from a single set of controls including "Up","Down", and "Mute." An indication should be provided for the currentlevel. It is recommended that the "Mute" button clearly indicate soundwaves for the unmuted state and the use the international symbol for"no' for the muted state.

b. Speech audio (i.e. locally reinforced speech) shall have a single set ofcontrols including "Up", "Down", and "Mute." An indication should beprovided for the current level.

E. Process

1. Prior to creating any custom code, the Integrator shall meet with theOwner to review graphic user interface (GUI) requirements. Best practicesas defined by the lnfocomm "Dashboard for AV Controls" shall be adheredto.

2. The Integrator shall demonstrate full systems programming to PHSDduring Full Project Verification. This code shall incorporate any changesdirected by PHSD during staging. The Integrator shall provide changes to theuser interface and/or control programming beyond that described by theapproved GUI, based on direction provided during verification.

3. Within 30 days after final acceptance of programming the Owner shallprovide to the AV Integrator in writing any requested software changes.Within 30 days of receipt of the request, the AV Integrator shall provide oneadditional site visit to implement changes to the user interface and/orcontrol programming.

F. Warranty

1. Upon successful completion of these services, the AV Integrator shallprovide an electronic copy of all software specific to this project to theOwner along with a nontransferable license to all software for the Owner'suse solely in connection with the maintenance and modification of thesesystems. All copies of the software shall remain in control of the Owner.Warranties relating to the software will apply only to the original,unmodified software, as provided by the AV Integrator at the end of theproject.

G. Qualifications

1. The individual responsible for programming the systems shall be aCrestron Certified Programmer with current certification credentials.

2. The Integrator shall include with the bid the resume(s) for theindividual(s) that will be providing custom programming services.

a. Indicate whether individual(s) is/are employees or subcontractors of theAV Integrator.

b. Provide a list of three to five recent projects of similar size and scopeprogrammed by the individual listed. Include references.

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-SPC1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 4: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

AV301

VGA 4

Audio 4

HDMI 1

HDMI 2

HDMI 3

HDMI 4

USB 1

USB 2

120v AC

ETH

VGA 3

DM

Audio 3

Audio L

Audio 2

HDMI

VGA 2

Audio 1

VGA 1

Mic

CrestronDMPS3-4K-150-C

Audio R

USB 3

USB 4

RS23

2

NET

IR

DM 1

DM 2

RELAY 1

Input 2

Input 1

RELAY 2

110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

PWR100

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

Audio InterfaceAllen & Heath AR2412

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 9

Mic/Line 10

Mic/Line 7

Mic/Line 8

Mic/Line 11

Mic/Line 15

Mic/Line 16

Mic/Line 12

Mic/Line 13

Mic/Line 14

Mic/Line 19

Mic/Line 20

Mic/Line 17

Mic/Line 18

Mic/Line 21

Mic/Line 22

Mic/Line 23

Mic/Line 24

Line 7

Line 8

Line 9

Line 10

Line 11

Line 12

120v AC Power

dSN

AKE

EXPA

NDE

R

MO

NIT

OR

5

AV3

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

System DSPQSC Q-SYS Core 110f

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 7

Mic/Line 8

Flex 1

GPIO In 1

Line 7

Line 8

Flex 2

Flex 3

Flex 4

Flex 5

Flex 6

Flex 7

Flex 8

GPIO Out 1

GPIO In 2 GPIO Out 2

GPIO In 3 GPIO Out 3

GPIO In 4 GPIO Out 4

GPIO In 5 GPIO Out 5

GPIO In 6 GPIO Out 6

GPIO In 7 GPIO Out 7

GPIO In 8 GPIO Out 8

HDMI

USB

Telephone

USB 1

USB 2

USB 3

USB 4

120v AC Power

ETH

RS23

2

ETH

12v DC Power

6

AV2

7

AV2

LOCALNET

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

Speaker 1 +/-

Left SubwooferRenkus Heinz CFX15S-8

Speaker 2 +/-

SPK104

Speaker 1 +/-

Left Top Array SpeakerRenkus Heinz CFX101LA-8

Speaker 2 +/-

SPK101

Speaker 1 +/-

Speaker 2 +/-

SPK201

Speaker 1 +/-

Speaker 2 +/-

SPK202

Speaker 1 +/-

Speaker 2 +/-

SPK203

Speaker 1 +/-

Speaker 2 +/-

SPK304

Speaker 1 +/-

Speaker 2 +/-

SPK102

Speaker 1 +/-

Speaker 2 +/-

SPK103

Speaker 1 +/-

Speaker 2 +/-

SPK301

Speaker 1 +/-

Speaker 2 +/-

SPK302

Speaker 1 +/-

Speaker 2 +/-

SPK303

Speaker 1 +/-

Left Fill SpeakerRenkus Heinz CFX41

SPK401

Speaker 1 +/-

Center Fill SpeakerRenkus Heinz CFX41

SPK402

Speaker 1 +/-

Right Fill SpeakerRenkus Heinz CFX41

SPK403

AUD401AUD301AUD202

AUD402

AUD403

AUD404

Ant 1A

Antenna/Power DistributorAudio-Technica ATW-DA49

Ant B

Ant A

12v DC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

AF Balanced

Wireless ReceiverAudio-Technica ATW-3192BI-TH

Ant B

Ant A

AF Unbalanced

12v Power

AUD203

AF Balanced

Wireless ReceiverAudio-Technica ATW-3141BI

Ant B

Ant A

AF Unbalanced

12v Power

AUD204

ANT201

LOCALNET

110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

PWR101

2

AV2

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT101

ANT102

3

AV3

4

AV3

8

AV2

18

AV2

19

AV2

20

AV2

17

AV2

14

AV2

15

AV2

16

AV2

13

AV2

10

AV2

11

AV2

12

AV2

9

AV2

1

AV3

Left Middle Array SpeakerRenkus Heinz CFX101LA-8

Left Bottom Array SpeakerRenkus Heinz CFX101LA-8

Center Top Array SpeakerRenkus Heinz CFX101LA-8

Center Middle Array SpeakerRenkus Heinz CFX101LA-8

Center Bottom Array SpeakerRenkus Heinz CFX101LA-8

Right Top Array SpeakerRenkus Heinz CFX101LA-8

Right Middle Array SpeakerRenkus Heinz CFX101LA-8

Right Bottom Array SpeakerRenkus Heinz CFX101LA-8

Right SubwooferRenkus Heinz CFX15S-8

21

AV2

22

AV2

24

AV2

23

AV2

29

AV4

47

AV2

48

AV2

A1

Equipment Low Voltage Connection Plan 1

ATW-A49 is a kit of two antennas,

use one kit to satisfy ANT101 and ANT102

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 5: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

PWR102

Mic 41

Line 45

Line 46

Line 21

Audio MixerAllen & Heath GLD-112

Line 47

Line 48

Line 22

Line 23

Line 24

Line 25

Line 26

SPDIF 27

SPDIF 28

AES/EBU 29

AES/EBU 30

Mic 42

Mic 43

Mic 44

MIDI In

MIDI Out

120v AC Power

ETH

dSN

AKE

EXPA

NDE

R

I/O

Por

t

ETH

5" TouchpanelCrestron TSW-560-B-S

AF Balanced

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Ant B

Ant A

AF Unbalanced

12v Power

AUD101

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD103

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD105

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD107

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD102

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD104

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD106

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD108

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

9

AV1

10

AV1

11

AV1

12

AV1

13

AV1

14

AV1

15

AV1

16

AV1

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT202

ANT203

ANT103

ANT104

6

AV1

7

AV1

LOCALNET

2

AV1

8

AV1

LOCALNET

AUD201

CTL101

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD109

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD111

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD110

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD112

17

AV1

18

AV1

19

AV1

20

AV1

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

ANT204

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Balanced Audio L

Balanced Audio RBalanced Audio R

Solid State RecorderDenon DN-500R

Unbalanced Audio R

Balanced Audio L

Unbalanced Audio R

Unbalanced Audio L

RS23

2

Rem

ote

1

Antenna - AM

Tuner Audio RAntenna - FM

CD PlayerDenon DN-300Z

CD/AUX Audio R

Tuner Audio L

110v AC

RS23

2

Rem

ote

1

AES/EBU

Coaxial

110v AC

Unbalanced Audio L

Coaxial

AES/EBU

CD/AUX Audio L

Balanced Audio L

Balanced Audio R

AUD113AUD302

21

AV1

22

AV1

USB 3.0 [1]USB 3.0 [2]USB 2.0 [1]USB 2.0 [2]USB 2.0 [3]USB 2.0 [4]USB 2.0 [5]USB 2.0 [6]

ETH

DP 2Audio

DP 1

PC

120v AC Power

HDMI SplitterKanexPro SP-HD1x24K

HDMI

5v DC Power

HDMI

HDMI

HD101

HD201

USB

Optical MouseGeneric

USB

KeyboardGeneric

DisplayDell P2017H

HDMI (MHL)

DisplayPort

120v AC Power

VGA

USB 3.0

USB 2.0

USB 2.0

DisplayDell P2017H

HDMI (MHL)

DisplayPort

120v AC Power

VGA

USB 3.0

USB 2.0

USB 2.0

HD203

HD202

LOCALNET

24

AV1

23

AV1

47

AV1

48

AV1

A2

Equipment Low Voltage Connection Plan 2

ATW-A49 is a kit of two antennas,

use one kit to satisfy ANT103 and ANT104

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV2
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 6: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

120v AC UP

Projection ScreenDa-Lite 70281L

120v AC DOWN

120v AC UPUP

Projection Screen LVCIncluded with Da-Lite 70281L

120v AC DOWNDOWN

120v AC Power

AV501 AV601

HDMI Out

Projector NEC NP-PA653UL

Lens NP43ZL

HDMI 2

HDMI 1

DisplayPort

Computer

Computer Audio

RGBHV

RGBHV Audio

3D Sync

ETH/

HDBT

RS23

2

Rem

ote

1

Audio

USB

120v AC Power

AV402

ETH

5" TouchpanelCrestron TSW-560-B-S

1

AV1

5

AV1

CTL102

DM

Wall Plate DM TransmitterCrestron DM-TX-200-C-2G-B-T

VGA

HDMI

24v Power

Audio

USB

DM

PoDM InjectorCrestron DM-PSU-ULTRA-MIDSPAN

DM

DM

110v DC Power

DM

AV201AV101

DM

Wall Plate DM TransmitterCrestron DM-TX-200-C-2G-B-T

VGA

HDMI

24v Power

Audio

USB

AV102

3

AV1

4

AV1

RELAY 1

Control Port ExpansionCrestron C2N-IO

NET

AV401

RELAY 2

COM

IR

LOCALNET

A3

Equipment Low Voltage Connection Plan 3

See Alternate #3

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV3
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 7: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

Audio InterfaceAllen & Heath AR2412

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 9

Mic/Line 10

Mic/Line 7

Mic/Line 8

Mic/Line 11

Mic/Line 15

Mic/Line 16

Mic/Line 12

Mic/Line 13

Mic/Line 14

Mic/Line 19

Mic/Line 20

Mic/Line 17

Mic/Line 18

Mic/Line 21

Mic/Line 22

Mic/Line 23

Mic/Line 24

Line 7

Line 8

Line 9

Line 10

Line 11

Line 12

120v AC Power

dSN

AKE

EXPA

NDE

R

MO

NIT

OR

AUD205

31

AVS1

32

AVS1

30

AVS1

29

AV1

33

AVS1

34

AVS1

35

AVS1

36

AVS1

37

AVS1

38

AVS1

39

AVS1

40

AVS1

41

AVD1

42

AVD1

43

AVD1

44

AVD1

45

AVD1

46

AVD1

Mix Output R

Assistive Listening TransmitterListen Tech LT-800-072-01

Input 2 R

Input 1

12v Power

Input 2 L

Antenna

AL101

Mix Output L

ANT

72-216MHz AntennaListen Tech LA-122

ANT107

50

AVS1

A3

Equipment Low Voltage Connection Plan 4

Listen Technologies LS-58-072

is a kit that includes these parts.

All remaining parts to be handed

over to PHSD at project completion.

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV4
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 8: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Aux

Base StationClear-Com BS210

IC1 2 Wire

Aux

IC1 4 Wire

12v DC Power

IC1 2 Wire

COM201

Announce

Two-Channel Main StationClear-Com MS-702

Panel Mic

Program

120v AC Power

Announce Relay

COM101

Hot Mic/IFB

Headset

ANT

Dual Diversity Dipole AntennaIncluded with COM101

ANT106

ANT

Dual Diversity Dipole AntennaIncluded with COM101

ANT105

Intercom Out

Remote Intercom StationClear Com KB-702

COM202

Intercom In

Headset

Intercom Out

Remote Intercom StationClear Com KB-702

COM203

Intercom In

Headset

Intercom Out

Remote Intercom StationClear Com KB-702

COM204

Intercom In

Headset

HandsetClear Com HS-6

COM303

Intercom

HeadsetClear Com CC-110-X4

COM304

Intercom

HeadsetClear Com CC-110-X4

COM305

Intercom

Wireless HeadsetClear Com CZ-WH220

COM301

Wireless

COM302

Wireless HeadsetClear Com CZ-WH220

Wireless

IC2 2 Wire

Int Ch A

Int Ch A

Int Ch A

Int Ch B

Int Ch B

Int Ch B

IC2 2 Wire

Channel A

Intercom PlateProCo Sound WPBA1028

FP102

Channel A

Channel B

IC2 4 Wire

Antenna

Antenna

Relay 1 (NC)

Relay 2 (Common)

Relay 3 (NO)

Relay 4 (N/A)

Relay 5 (Ground)

Intercom Out

Call Signal FlasherClear Com FL-7

COM205

Intercom In

Intercom Out

Call Signal FlasherClear Com FL-7

COM206

Intercom In

Channel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP101

Channel A

Channel BChannel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP103

Channel A

Channel BChannel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP104

Channel A

Channel BChannel B

A3

Equipment Low Voltage Connection Plan 5

See Alternate #2

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV5
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 9: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Middle Atlantic 1U Blank [EB1]

AUD404

Middle Atlantic 1U Blank [EB1]

AUD403

Middle Atlantic 1U Blank [EB1]

AUD402

Middle Atlantic 1U Blank [EB1]

AUD401

Middle Atlantic 1U Blank [EB1]

PWR 101

Middle Atlantic 1U Blank [EB1]

PWR100

Middle Atlantic 1U Blank [EB1]

AUD301

Middle Atlantic 1U Blank [EB1]

AUD205

Middle Atlantic 1U Blank [EB1]

AUD203 AUD204

ANT201

Middle Atlantic 1U Blank [EB1]

AV301

COM201

COM101

Middle Atlantic 1U Blank [EB1]

Pathway DMX Repeater

Middle Atlantic 1U Blank [EB1]

Middle Atlantic 1U Blank [EB1]

Middle Atlantic 1U Blank [EB1]

AL101

AUD202

Middle Atlantic 1U Blank [EB1]

Middle Atlantic 1U Blank [EB1]

Middle Atlantic 1U Blank [EB1]

CTL101

AUD101 AUD102

AUD103 AUD104

AUD105 AUD106

ANT203

PWR102

AUD107 AUD108

AUD109 AUD110

AUD111 AUD112

Middle Atlantic 1U Blank [EB1]

Middle Atlantic 1U Blank [EB1]

ANT202

Middle Atlantic 1U Blank [EB1]

ANT204

Middle Atlantic 1U Blank [EB1]

AUD302

AUD113

A4

Equipment Rack ER01 Layout

A5

Equipment Rack ER02 Layout

All rackscews on Equipment

Rack ER02 shall be Middle

Atlantic HTX Star Post

Drive Security Screws.

CTL101 Shall be mounted in a

modified Middle Atlantic EB2

2U Blank.

Rack ER01 shall be Middle

Atlantic WRK-37SA-27

Enclosure with two (2) Middle

Atlantic LACE-37-OWP Lace

Strips installed and one (1)

(additional) Middle Atlantic

WRK-RR37 Rack Rail Pair

Installed

Middle Atlantic LBP Series

Horizontal Lacer Bars shall be

provided and installed as

required.

Rack ER02 shall be Middle Atlantic

DTRK-1818 Enclsoure.

AUD202 and AUD205 shall

be installed in reverse

(Interfaces to rear) on second

set of installed rack rails.

Front set of rails shall be

covered with Middle Atlantic

EB3 3U Blank.

All rackscews on Equipment

Rack ER01 shall be Middle

Atlantic HP Truss-Head

rackscrews.

Audio-Technica AT8630

Joining Plate Kit Required

Audio-Technica AT8630

Joining Plate Kit Required

Audio-Technica AT8630

Joining Plate Kit Required

Back of rack to be filled with

Middle Atlantic EB2 2U Blanks

and one Middle Atlantic BR2 2U

Brush Grommet Panel.

Existing DMX Repeater

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AV6
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 10: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

AV301

VGA 4

Audio 4

HDMI 1

HDMI 2

HDMI 3

HDMI 4

USB 1

USB 2

120v AC

ETH

VGA 3

DM

Audio 3

Audio L

Audio 2

HDMI

VGA 2

Audio 1

VGA 1

Mic

CrestronDMPS3-4K-150-C

Audio R

USB 3

USB 4

RS23

2

NET

IR

DM 1

DM 2

RELAY 1

Input 2

Input 1

RELAY 2

110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

LocalPower

PWR100

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

Audio InterfaceAllen & Heath AR2412

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 9

Mic/Line 10

Mic/Line 7

Mic/Line 8

Mic/Line 11

Mic/Line 15

Mic/Line 16

Mic/Line 12

Mic/Line 13

Mic/Line 14

Mic/Line 19

Mic/Line 20

Mic/Line 17

Mic/Line 18

Mic/Line 21

Mic/Line 22

Mic/Line 23

Mic/Line 24

Line 7

Line 8

Line 9

Line 10

Line 11

Line 12

120v AC Power

dSN

AKE

EXPA

NDE

R

MO

NIT

OR

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

System DSPQSC Q-SYS Core 110f

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 7

Mic/Line 8

Flex 1

GPIO In 1

Line 7

Line 8

Flex 2

Flex 3

Flex 4

Flex 5

Flex 6

Flex 7

Flex 8

GPIO Out 1

GPIO In 2 GPIO Out 2

GPIO In 3 GPIO Out 3

GPIO In 4 GPIO Out 4

GPIO In 5 GPIO Out 5

GPIO In 6 GPIO Out 6

GPIO In 7 GPIO Out 7

GPIO In 8 GPIO Out 8

HDMI

USB

Telephone

USB 1

USB 2

USB 3

USB 4

120v AC Power

ETH

RS23

2

ETH

12v DC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

CH1Audio CH1

Audio AmplifierPowerSoft M28Q

CH2Audio CH2

Audio CH3

Audio CH4

CH3

CH4

120v AC Power

Speaker 1 +/-

Left SubwooferRenkus Heinz CFX15S-8

Speaker 2 +/-

SPK104

Speaker 1 +/-

Left Top Array SpeakerRenkus Heinz CFX101LA-8

Speaker 2 +/-

SPK101

Speaker 1 +/-

Speaker 2 +/-

SPK201

Speaker 1 +/-

Speaker 2 +/-

SPK202

Speaker 1 +/-

Speaker 2 +/-

SPK203

Speaker 1 +/-

Speaker 2 +/-

SPK304

Speaker 1 +/-

Speaker 2 +/-

SPK102

Speaker 1 +/-

Speaker 2 +/-

SPK103

Speaker 1 +/-

Speaker 2 +/-

SPK301

Speaker 1 +/-

Speaker 2 +/-

SPK302

Speaker 1 +/-

Speaker 2 +/-

SPK303

Speaker 1 +/-

Left Fill SpeakerRenkus Heinz CFX41

SPK401

Speaker 1 +/-

Center Fill SpeakerRenkus Heinz CFX41

SPK402

Speaker 1 +/-

Right Fill SpeakerRenkus Heinz CFX41

SPK403

AUD401AUD301AUD202

AUD402

AUD403

AUD404

Ant 1A

Antenna/Power DistributorAudio-Technica ATW-DA49

Ant B

Ant A

12v DC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

AF Balanced

Wireless ReceiverAudio-Technica ATW-3192BI-TH

Ant B

Ant A

AF Unbalanced

12v Power

AUD203

AF Balanced

Wireless ReceiverAudio-Technica ATW-3141BI

Ant B

Ant A

AF Unbalanced

12v Power

AUD204

ANT201

120v AC 12v DC110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

PWR101

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT101

ANT102

LocalPower

Left Middle Array SpeakerRenkus Heinz CFX101LA-8

Left Bottom Array SpeakerRenkus Heinz CFX101LA-8

Center Top Array SpeakerRenkus Heinz CFX101LA-8

Center Middle Array SpeakerRenkus Heinz CFX101LA-8

Center Bottom Array SpeakerRenkus Heinz CFX101LA-8

Right Top Array SpeakerRenkus Heinz CFX101LA-8

Right Middle Array SpeakerRenkus Heinz CFX101LA-8

Right Bottom Array SpeakerRenkus Heinz CFX101LA-8

Right SubwooferRenkus Heinz CFX15S-8

25

AVP3

26

AVP5

27

AVP5

28

AVP4

49

AVP4

P1

Equipment Power Connection Plan 1

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVP1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 11: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

110v AC

Status RelayControl

Power DistributionMiddle Atlantic PDC-915R-6

110v AC (1)

110v AC (2)

110v AC (3)

110v AC (4)

110v AC (5)

110v AC (6)

110v AC NC

Surge Status

110v AC NC

110v AC NC Front

LocalPower

PWR102

Mic 41

Line 45

Line 46

Line 21

Audio MixerAllen & Heath GLD-112

Line 47

Line 48

Line 22

Line 23

Line 24

Line 25

Line 26

SPDIF 27

SPDIF 28

AES/EBU 29

AES/EBU 30

Mic 42

Mic 43

Mic 44

MIDI In

MIDI Out

120v AC Power

ETH

dSN

AKE

EXPA

NDE

R

I/O

Por

t

ETH

5" TouchpanelCrestron TSW-560-B-S

AF Balanced

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Ant B

Ant A

AF Unbalanced

12v Power

AUD101

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD103

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD105

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD107

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD102

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD104

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD106

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD108

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT

LPDA AntennaAudio-Technica ATW-A49

ANT202

ANT203

ANT103

ANT104

AUD201

CTL101

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD109

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD111

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD110

AF Balanced

Ant B

Ant A

AF Unbalanced

12v Power

AUD112

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Ant 1A

Antenna/Power DistributorAudio-Technica AEW-DA550C

Ant B

Ant A

120v AC Power

Ant 1B

Ant 2A

Ant 2B

Ant 3A

Ant 3B

Ant 4A

Ant 4B

12V DC Power

12V DC Power

12V DC Power

12V DC Power

ANT204

Ant A Cascade

Ant B Cascade

120v AC Pwr Thru

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Wireless ReceiverAudio-Technica ATW-3192BC-TH

Balanced Audio L

Balanced Audio RBalanced Audio R

Solid State RecorderDenon DN-500R

Unbalanced Audio R

Balanced Audio L

Unbalanced Audio R

Unbalanced Audio L

RS23

2

Rem

ote

1

Antenna - AM

Tuner Audio RAntenna - FM

CD PlayerDenon DN-300Z

CD/AUX Audio R

Tuner Audio L

110v AC

RS23

2

Rem

ote

1

AES/EBU

Coaxial

110v AC

Unbalanced Audio L

Coaxial

AES/EBU

CD/AUX Audio L

Balanced Audio L

Balanced Audio R

AUD113AUD302

USB 3.0 [1]USB 3.0 [2]USB 2.0 [1]USB 2.0 [2]USB 2.0 [3]USB 2.0 [4]USB 2.0 [5]USB 2.0 [6]

ETH

DP 2Audio

DP 1

PC

120v AC Power

HDMI SplitterKanexPro SP-HD1x24K

HDMI

5v DC Power

HDMI

HDMI

HD101

HD201

USB

Optical MouseGeneric

USB

KeyboardGeneric

LocalPower

LocalPower

LocalPower

120v AC 5v DCLocalPower

DisplayDell P2017H

HDMI (MHL)

DisplayPort

120v AC Power

VGA

USB 3.0

USB 2.0

USB 2.0

DisplayDell P2017H

HDMI (MHL)

DisplayPort

120v AC Power

VGA

USB 3.0

USB 2.0

USB 2.0

HD203

HD202

P2

Equipment Power Connection Plan 2

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVP2
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 12: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

120v AC UP

Projection ScreenDa-Lite 70281L

120v AC DOWN

120v AC UPUP

Projection Screen LVCIncluded with Da-Lite 70281L

120v AC DOWNDOWN

120v AC Power

AV501 AV601

HDMI Out

Projector NEC NP-PA653UL

Lens NP43ZL

HDMI 2

HDMI 1

DisplayPort

Computer

Computer Audio

RGBHV

RGBHV Audio

3D Sync

ETH/

HDBT

RS23

2

Rem

ote

1

Audio

USB

120v AC Power

AV402

ETH

5" TouchpanelCrestron TSW-560-B-S

CTL102

DM

Wall Plate DM TransmitterCrestron DM-TX-200-C-2G-B-T

VGA

HDMI

24v Power

Audio

USB

DM

PoDM InjectorCrestron DM-PSU-ULTRA-MIDSPAN

DM

DM

110v DC Power

DM

AV201AV101

DM

Wall Plate DM TransmitterCrestron DM-TX-200-C-2G-B-T

VGA

HDMI

24v Power

Audio

USB

AV102

RELAY 1

Control Port ExpansionCrestron C2N-IO

NET

AV401

RELAY 2

COM

IR

LocalPower

LocalPower

25

AVP1

P3

Equipment Power Connection Plan 3

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVP3
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 13: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Mic/Line 1

Mic/Line 5

Mic/Line 6

Line 1

Audio InterfaceAllen & Heath AR2412

Line 2

Line 3

Line 4

Line 5

Line 6

Mic/Line 2

Mic/Line 3

Mic/Line 4

Mic/Line 9

Mic/Line 10

Mic/Line 7

Mic/Line 8

Mic/Line 11

Mic/Line 15

Mic/Line 16

Mic/Line 12

Mic/Line 13

Mic/Line 14

Mic/Line 19

Mic/Line 20

Mic/Line 17

Mic/Line 18

Mic/Line 21

Mic/Line 22

Mic/Line 23

Mic/Line 24

Line 7

Line 8

Line 9

Line 10

Line 11

Line 12

120v AC Power

dSN

AKE

EXPA

NDE

R

MO

NIT

OR

AUD205

28

AVP1

Mix Output R

Assistive Listening TransmitterListen Tech LT-800-072-01

Input 2 R

Input 1

12v Power

Input 2 L

Antenna

AL101

Mix Output L

120v AC 12v DC49

AVP1

ANT

72-216MHz AntennaListen Tech LA-122

ANT107

P3

Equipment Power Connection Plan 4

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVP4
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 14: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Aux

Base StationClear-Com BS210

IC1 2 Wire

Aux

IC1 4 Wire

12v DC Power

IC1 2 Wire

COM201

Announce

Two-Channel Main StationClear-Com MS-702

Panel Mic

Program

120v AC Power

Announce Relay

COM101

Hot Mic/IFB

Headset

ANT

Dual Diversity Dipole AntennaIncluded with COM101

ANT106

ANT

Dual Diversity Dipole AntennaIncluded with COM101

ANT105

Intercom Out

Remote Intercom StationClear Com KB-702

COM202

Intercom In

120v AC 12v DC26

AVP1

Headset

Intercom Out

Remote Intercom StationClear Com KB-702

COM203

Intercom In

Headset

Intercom Out

Remote Intercom StationClear Com KB-702

COM204

Intercom In

Headset

HandsetClear Com HS-6

COM303

Intercom

HeadsetClear Com CC-110-X4

COM304

Intercom

HeadsetClear Com CC-110-X4

COM305

Intercom

Wireless HeadsetClear Com CZ-WH220

COM301

Wireless

COM302

Wireless HeadsetClear Com CZ-WH220

Wireless

27

AVP1

IC2 2 Wire

Int Ch A

Int Ch A

Int Ch A

Int Ch B

Int Ch B

Int Ch B

IC2 2 Wire

Channel A

Intercom PlateProCo Sound WPBA1028

FP102

Channel A

Channel B

IC2 4 Wire

Antenna

Antenna

Relay 1 (NC)

Relay 2 (Common)

Relay 3 (NO)

Relay 4 (N/A)

Relay 5 (Ground)

Intercom Out

Call Signal FlasherClear Com FL-7

COM205

Intercom In

Intercom Out

Call Signal FlasherClear Com FL-7

COM206

Intercom In

Channel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP101

Channel A

Channel BChannel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP103

Channel A

Channel BChannel B

Channel A

Intercom PlateProCo Sound WPBA1028

FP104

Channel A

Channel BChannel B

P3

Equipment Power Connection Plan 5

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVP5
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 15: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

2P

2P

F1

Area Floor Plan - Level 1

AVS3

F3

AVD1D1

AVD2D1

A

V

D

1

D

3

Existing XLR Input

38

AV4

Existing XLR Input

39

AV4

Existing XLR Input

40

AV4

Existing XLR Inputs

33

AV4

32

AV4

31

AV4

30

AV4

Existing XLR Inputs

37

AV4

36

AV4

35

AV4

34

AV4

Data location to be

provided by others.

Data location to be

provided by others.

50

AV4

ProCo Sound WPBA1027

AutoCAD SHX Text
DC
AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVS1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 16: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

15

'

15°

20

'2

0'

1'

61

'-1

0"

1'

F2

Area Floor Plan - Level 2

AVS3

F3

AVS4

F4

AVS5

F6

AVS4

F5

SPK101,SPK102

SPK103,SPK104

AV402

SPK201,SPK202

SPK203

SPK301,SPK302

SPK303,SPK304

AV601

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVS2
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 17: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

25'

14'-4

13

16

"

18'

F3

Centerline Section

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVS3
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 18: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

F5

Enlarged Second Level Equipment Plan - AV Booth

F4

Enlarged Second Level Speaker Plan - AV Booth

Existing Road Hog

Lighting Console

AUD201

Audio Mixer

ER02

Equipment Rack

HD101, HD201

HD202, HD203

Computer System

ER01

Equipment Rack

SPK401SPK402SPK403

Speakers are to be placed

above window opening.

Install with UBRKT/41 brackets

Install AV101 above counter

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVS4
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 19: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

F6

Enlarged Second Level Intercom Plan - AV Booth

COM202 COM203 COM204COM205 COM206

FP101 FP104 FP102 FP103

F7

TBD

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVS5
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151
Page 20: SITE INDEX OF DRAWINGS - boe.parkhill.k12.mo.us

Demo existing speaker

cluster including all

associated rigging

and cabling

D1

East Stage Wall Equipment Location Detail

D2

West Stage Wall Equipment Location Detail

D3

Existing Cluster Removal Notes

D4

TBD

Install CTL102 at same

elevation as light control

touch panel.

ProCo Sound WPUBA2011

(2) Neutrik NC3FD-L-B-1

(2) Neutrik NC3MD-L-B-1

All connections to AUD205

Top Left (M) -

Top Right (M) -

Bottom Left (F) -

Bottom Right (F) -

Install AV102 at same

elevation as electrical outlet.

45

AV4

46

AV4

41

AV4

42

AV4

ProCo Sound WPUBA2011

(2) Neutrik NC3FD-L-B-1

(2) Neutrik NC3MD-L-B-1

All connections to AUD205

Top Left (M) -

Top Right (M) -

Bottom Left (F) -

Bottom Right (F) -

45

AV4

46

AV4

43

AV4

44

AV4

Provide

surface box and conduit.

Provide surface box and

conduit. Install box at

same elevation as

electrical outlet.

AutoCAD SHX Text
Drafted By:
AutoCAD SHX Text
Approved By:
AutoCAD SHX Text
Title:
AutoCAD SHX Text
File Name
AutoCAD SHX Text
Date:
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
Technology Department
AutoCAD SHX Text
Kansas City, MO 64153
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Ryan Kucharo
AutoCAD SHX Text
Manager of Network and Infrastructure
AutoCAD SHX Text
2/14/2017
AutoCAD SHX Text
PHHSAuditoriumAV-2017.dwg
AutoCAD SHX Text
PHHS-AVD1
AutoCAD SHX Text
Park Hill School District
AutoCAD SHX Text
7703 NW Barry Rd
AutoCAD SHX Text
Kansas City, MO 64151