SITE PHOTOMETRIC PLAN - City of Thornton...2016/06/15 · C1C2 2 OF 13 PROPOSED SITE PLAN AS...
2
C1 C2 2 OF 13 PROPOSED SITE PLAN AS INDICATED J. NATE REEVE, P.E. T. PRIDEMORE 15157 DP 2016-007 2" 1" 0" 5 4 3 2 1 5 4 3 2 1 D C B A SCALE DRAWN BY CHECKED BY PROJECT NUMBER FILE SEAL DATE STATUS DATE REVISION Reeve & Associates, Inc. PROJECT NUMBER: 5799-279 DRAWN BY: RWH ENGINEER: JNR DEVELOPMENT PERMIT GRANGE CREEK FILING 9 MAVERIK SITE PLAN Updated to a 3/4 Movement
SITE PHOTOMETRIC PLAN - City of Thornton...2016/06/15 · C1C2 2 OF 13 PROPOSED SITE PLAN AS INDICATED J. NATE REEVE, P.E. T. PRIDEMORE 15157 DP 2016-007 2" 1" 0" 1 2 3 4 5 1 2 3
112th Avenue is a minor arterial at build out. 112th & Colorado is planned to have double left turn lanes in all directions in future. This access must be 3/4 movement with a left out prohibited. A channelizing island must be constructed to prevent left turns out. Access is not approved if changes are not made.
2"
1"
0"
54321
54321
DC
BA
SCALE
DRAWN BY
CHECKED BY
PROJECT NUMBER
FILE
SEAL
DATE STATUS
DATE REVISION
Consulting Engineers
This document and the ideas and designsincorporated herein, as an instrument of
professional service, is the property of NIELSONENGINEERING, INC. and is not to be used, in
whole or in part,for any other project without thewritten authorization of an authorized
representative of NIELSON ENGINEERING,INC. Unauthorized use will be
prosecuted to the fullest extent of the Law.Copyright c 2016 by:
NIELSON ENGINEERING, INC.
Nielson Engineering, Inc.
OWNERSHIP OF DOCUMENTS
Pocatello, Idaho 83201PHONE (208) 232-2577
120 North Twelfth Avenue
FAX (208) 234-0918
SITE PHOTOMETRIC PLAN
As indicated
E-1.2
PHOTOMETRIC
PLAN
MSI
MJE
16302
11 of 13
Adjusted
AutoCAD SHX Text
E
AutoCAD SHX Text
27241
AutoCAD SHX Text
O
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
A
AutoCAD SHX Text
R
AutoCAD SHX Text
O
AutoCAD SHX Text
L
AutoCAD SHX Text
O
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
R
AutoCAD SHX Text
A.
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
S
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
G
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
D
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
G:\Maverik\5000 Prototype\Aurora, CO # (Chambers) - 15368\Elec\AURORA (CHAMBERS) E-1.2.dwg November 20 2015 1:32pm By:Jill
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1"=30'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
E-1.2
AutoCAD SHX Text
MASTER LUMINAIRE SCHEDULE
AutoCAD SHX Text
LAMPS
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
CATALOG NUMBER
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
IMAGE
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
T-6
AutoCAD SHX Text
INCLUDED
AutoCAD SHX Text
WALL MOUNTED ANGLE LUMINAIRE WITH 23" CROOKED ARM, LED, 1420 LUMENS, FROSTED GLASS JAR
AutoCAD SHX Text
SPECTRUM LIGHTING
AutoCAD SHX Text
AR1214LEDGV/14W 40K/E1/FJ1/PA23/CP104/CC
AutoCAD SHX Text
WALL
AutoCAD SHX Text
HEIGHT SPECIFIED
AutoCAD SHX Text
BY ARCHITECT
AutoCAD SHX Text
T-11
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
T-12
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
T-13
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
T-14
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
T-15
AutoCAD SHX Text
DESCRIPT.
AutoCAD SHX Text
MT
AutoCAD SHX Text
RECESSED DOWN LIGHT 8" APERTURE, WET LISTED, WIDE DISTRIBUTION, 1800 LUMEN, WHITE TRIM, 5-YEAR WARRANTY, 4K
AutoCAD SHX Text
GOTHAM
AutoCAD SHX Text
EVO41/18 8WR WD 120 AZ10
AutoCAD SHX Text
RECESSED
AutoCAD SHX Text
INCLUDED
AutoCAD SHX Text
T-11B
AutoCAD SHX Text
SAME AS T-11 EXCEPT WITH EMERGENCY BATTERY
AutoCAD SHX Text
120
AutoCAD SHX Text
FULL CUTOFF WALL PACK , 30 LED, DB
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
CSXW LED 30C 700 40K T3M MVOLT DDBXD
AutoCAD SHX Text
INCLUDED
AutoCAD SHX Text
WALL
AutoCAD SHX Text
HEIGHT SPECIFIED
AutoCAD SHX Text
BY ARCHITECT
AutoCAD SHX Text
208
AutoCAD SHX Text
POLE MOUNTED, CUTOFF LUMINAIRE SINGLE HEAD, LED, 16,000 LUMENS, 25FT SQUARE POLE
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
KAD LED 60C 1000 40K R3 MVOLT SPD04 DDBXD
AutoCAD SHX Text
INCLUDED
AutoCAD SHX Text
25'-0" POLE
AutoCAD SHX Text
T-14A
AutoCAD SHX Text
T-14C
AutoCAD SHX Text
SAME AS T-14 EXCEPT WITH TYPE IV DISTRIBUTION (FORWARD THROW)
AutoCAD SHX Text
SAME AS T-14 EXCEPT DOUBLE HEAD IN "L" CONFIGURATION (NOT USED)