    Both for the V3 and V2 site, the ID_DOG have 15 bits in logical. There are

    two switches S1 and S2 physically.

    For each bit of S1 and S2, status ON means 0, OFF means 1

    S1 bits 18 are mapped ID_DOG logical bits 07; S2 bit 18 are mapped

    ID_DOG logical bits 815;

    V3

    F I G U R E 1 - CA B I N E T -TO P DIP S W I T C H E S

    14 13 345678910111215 012

    B TS_TY PE BTS_N OSLAVE1_

    PORT

    SLAVE2_

    PORTSATE ABIS_PORT ABIS_TS

    The meaning of each bit is explained as follows:

    NO Name Meaning Description

    15 BTS_TYPE BTS TYPE 1100: B8018

    14 1101: B811213 1110: M8202

    12 1111: M8204

    11 BTS_NO No. of the cabinet of the samesite

    00: Basic cabinet

    01: Extended cabinet

    10: Extended cabinet10

    9 SLAVE1_PORT The E1 port of the basic cabinetto connect extended cabinet 1

    00: Port E of the basic cabinet

    01: Port F of the basic cabinet

    10: Port G of the basic cabinet

    11: Port H of the basic cabinet

    8

    7 SLAVE2_PORT The E1 port of the basic cabinetto connect extended cabinet 2

    00: Port E of the basic cabinet

    01: Port F of the basic cabinet

    10: Port G of the basic cabinet

    11: Port H of the basic cabinet

    6

    5 SATE Whether to use the satellite Abislink or not

    0: Common Abis

    1: Satellite Abis

    4 ABIS_PORT O&M port number 00: Port A 01: Port B

    10: Port C 11: Port D3

    2 ABIS_TS The O&M LAPD timeslot on theAbis interface

    000: TS16 001: TS31 010: TS30

    011: TS29 100: TS28 101: TS27

    110: TS26 111: TS25

    1

    0

    The number of the E1 port of the basic cabinet to connect the lower-level site cannot be

    the same as of SLAVE_PORT1 or SLAVE_PORT2. For example, suppose Port F of

    the basic cabinet connects with the lower-level site, then the values of SLAVE_PORT1

  • 7/31/2019 Site Top DIP Switch

    2/5

    and SLAVE_PORT2 cannot be 01.

    For example,site1 and site2 are BTS B8018,site2 is the downsite of site1.Both sites use

    the common Abis,site1 E1 port A connect to BSC,site2 E1 port A connect to site1 port

    D. The O&M timeslot of site2 is TS31.Then the dip switches areSite1: S1(18) 00000000 S2(18) 00000011

    Site2: S1(18) 10000000 S2(18) 00000011

    V2

    15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

    INDOOR SYN CHANEL_NO BTS_NO SLAVE1_PO RT SLAVE2_P ORT SATE ABIS_PORT ABIS_TS

    The meaning of each bit is explained as follows:

    NO Name Meaning Description

    15 INDOOR BTS TYPE 0: Indoor 1:Outdoor

    14 SYN Network syn_clock source 0: Get from E1 1: SDH syn_clock 13 CHANNEL_NO Port of the monitor 00:RS232 for transparent channel

    01:RS422 for transparent channel

    10:RS232 for SMC

    12

    11 BTS_NO No. of the cabinet of the samesite

    00: Basic cabinet

    01: Extended cabinet

    10: Extended cabinet10

    9 SLAVE1_PORT The E1 port of the basic cabinetto connect extended cabinet 1

    00: Port C of the basic cabinet

    01: Port D of the basic cabinet

    10: Port E of the basic cabinet

    11: Port F of the basic cabinet

    8

    7 SLAVE2_PORT The E1 port of the basic cabinetto connect extended cabinet 2

    00: Port C of the basic cabinet

    01: Port D of the basic cabinet

    10: Port E of the basic cabinet

    11: Port F of the basic cabinet

    6

    5 SATE Whether to use the satellite Abislink or not

    0: Common Abis

    1: Satellite Abis

    4 ABIS_PORT O&M port number 00: Port A 01: Port B

    10: Port C 11: Port D3

    2 ABIS_TS The O&M LAPD timeslot on theAbis interface

    000: TS16 001: TS31 010: TS30

    011: TS29 100: TS28 101: TS27

    110: TS26 111: TS25

    1

    0

    The number of the E1 port of the basic cabinet to connect the lower-level site cannot be

    the same as of SLAVE_PORT1 or SLAVE_PORT2. For example, suppose Port D of

    the basic cabinet connects with the lower-level site, then the values of SLAVE_PORT1

    and SLAVE_PORT2 cannot be 01.

  • 7/31/2019 Site Top DIP Switch

    3/5

    For example,site1 and site2 are BTSV2,site2 is the downsite of site1.Both sites use the

    common Abis, site1 E1 port A connect to BSC,site2 E1 port A connect to site1 port

    D.The O&M timeslot of site2 is TS31.Then the dip switches are

    Site1: S1(18) 00000000 S2(18) 00000000

    Site2: S1(18) 10000000 S2(18) 00000000

    Note

    To check the DIP switch status in site by signal trace

    Site Power On Report (157)- last 4 they are in HEX change to BINARY this is for ibsc

    For V2 leaving last 2 next 4 (Reset site and find this message in signal tracing(OAM))

  • 7/31/2019 Site Top DIP Switch

    4/5

    DIP Configuration for Micro BTS(M8202)

    S1 S2 S3

    Figure 1: For Common Abis (Abis TS 16)

    S1 S2

    S3

    Figure 2: For Satellite Abis (Abis TS 25)

    1

    OFF

    2

    OFF

    3

    ON

    4

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON

    5

    ON

    6

    OFF7

    OFF

    8

    OFF

    1

    OFF

    2

    OFF

    3

    ON

    4

    OFF

  • 7/31/2019 Site Top DIP Switch

    5/5