Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where non-compliance against a particular condition has not been reported, this should not be construed to mean that there is full compliance with that condition of the licence. Instructions and actions arising from the visit shall be addressed, or where applicable noted, by the licensee in order to ensure compliance, to improve the environmental performance of the installation and to provide clarification on certain issues. The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report. Licensee Name of Installation Medite Europe Limited Licensee Medite Europe Limited Licence Register No. P0027-02 CRO Number 80984 Site Address Redmondstown, Clonmel, Tipperary Site Visit Reference No. SV08076 Report Detail Issue Date 14/10/2016 Prepared By David Matthews Site Visit Detail Date Of Inspection 26/07/2016 Announced No Time In 14:00 Time Out 13:00 Visited by on behalf of the EPA Exova Ltd. Licensee Personnel and Role See report Photo Taken No Samples Taken Yes Video Taken No Site Visit Report - SV08076 - Medite Europe Limited Page 1 of 83

Site Visit Report - Environmental Protection Agency ... · Site Visit Report The site visit ... Monitoring & Analytical Methods Sampling Location ... 1.96 130 127.79 317.14 153.89

Embed Size (px)

Citation preview

Site Visit Report

The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions.  Where non-compliance against a particular condition has not been reported, this should not be construed to mean that there is full compliance with that condition of the licence.

Instructions and actions arising from the visit shall be addressed, or where applicable noted, by the licensee in order to ensure compliance, to improve the environmental performance of the installation and to provide clarification on certain issues.

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Licensee

Name of Installation Medite Europe Limited

Licensee Medite Europe Limited

Licence Register No. P0027-02

CRO Number 80984

Site Address Redmondstown, Clonmel, Tipperary

Site Visit Reference No. SV08076

Report Detail

Issue Date 14/10/2016

Prepared By David Matthews

Site Visit Detail

Date Of Inspection 26/07/2016 Announced No

Time In 14:00 Time Out 13:00

Visited by on behalf of the EPA Exova Ltd.

Licensee Personnel and Role See report

Photo Taken No Samples Taken Yes Video Taken No

Site Visit Report - SV08076 - Medite Europe Limited Page 1 of 83

Scope

This is a report on monitoring of emissions to atmosphere at this site. Please find the detailed technical report attached.

Media

Air

Site Areas Inspected

See report

Documents Inspected

See report

Site Visit Report - SV08076 - Medite Europe Limited Page 2 of 83

Site Visit Report - SV08076 - Medite Europe Limited Page 3 of 83

ISO/IEC 17025 Accredited Legal Entity, UKAS Accredited Testing Laboratory No. 4279

Exova (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland

Unit C5, Emery Court, The Embankment Business Park, Stockport, SK4 3GL

EMISSIONS REPORTEPA AIR EMISSIONS COMPLIANCE MONITORING

Exova Catalyst Ireland, Unit D8 North City Business Park, North Road, Finglas, Dublin 11

T: +353 86 853 8247E: [email protected]

Your Exova Catalyst Ireland Contact: Nick Kenny (+353 86 853 8247)

Clonmel

RedmondstownMedite Europe Ltd

IrelandCo Tipperary

EPA Office of Environmental Enforcement

EP 35 - Face Dryer Stage 1

DELETE & COVER ME

(Prepared on behalf of the EPA by Exova Catalyst - EPA Contract No. OEE-14-DS)-

-

Team Leader

Deputy Regional Manager

TE1 TE2 TE3 TE4MM 08 922

MCERTS Level 2

Patrick O'Brien

Report Approved by

MM 10 1074MCERTS Level 2

Stack Emissions Testing Report Commissioned by

26th - 27th July 2016

Job Reference Number

CDU-0666-CAR16-01

Installation Name & Address

Dates of the Monitoring Campaign

Report Written by

John Glennon

19th September 2016

Report Date

TE1 TE2 TE3 TE4

Version

Stack Reference

Industrial Emissions Licence: P0027-02

Signature of Report Approver

Version 1

CAT-RT (Version BO)Site Visit Report - SV08076 - Medite Europe Limited Page 4 of 83

TITLE PAGE

CONTENTS

Summary of Sampling Deviations

EXECUTIVE SUMMARY

Monitoring Objectives

Monitoring Results

Monitoring Dates & Times

Process Details

Monitoring & Analytical Methods

Sampling Location

Plant Photos / Sample Points

APPENDIX 1 - Monitoring Personnel & List of Equipment

APPENDIX 2 - Raw Data, Sampling Equations & Charts

The testing performed fully meets the technical requirements in Irish

EPA Guidance Note, AG2.

9

3

5

6

8

Opinions and interpretations expressed herein are outside the scope of

Exova Catalyst Ireland's ISO 17025 accreditation.

This test report shall not be reproduced, except in full, without the

written approval of Exova Catalyst Ireland.

7

CONTENTS

4

2

CAT-RT (Version BO)

Page 2 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 5 of 83

Overall Aim of the Monitoring Campaign

Special Requirements

Target Parameters

Exova Catalyst Ireland were commissioned by EPA Office of Environmental Enforcement to carry out stack emissions testing for

Medite Europe Ltd on the EP 35 - Face Dryer Stage 1 at Clonmel.

The aim of the monitoring campaign was to demonstrate compliance with a set of emission limit values (ELVs) as specified in

the Site's Licence.

There were no special requirements.

Total Particulate Matter | Condensable VOCs | Cadmium & Thallium | Heavy Metals | Mercury | Dioxins & Furans |

Formaldehyde | Isocyanates | Oxides of Nitrogen (as NO₂) | Carbon Monoxide |

MONITORING OBJECTIVES

Executive Summary

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

26th - 27th July 2016

(Page 1 of 7)

CAT-RT (Version BO)

Page 3 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 6 of 83

where MU = Measurement Uncertainty associated with the Result

Parameter

Total Particulate Matter ¹

Condensable VOCs ¹ - -

Cadmium & Thallium ¹ - -

Heavy Metals ¹ - -

Mercury ¹ - -

Dioxins & Furans (NATO I-TEQ) - R1 Dioxins & Furans ¹

Formaldehyde ¹ - -

Isocyanates ¹ < <

Oxides of Nitrogen (as NO₂) ¹ - -

Carbon Monoxide ¹ - -

Oxygen Wet Dry

Water Vapour

Stack Gas Temperature

Stack Gas Velocity 2

1 & 2

- -

NOTE: VOLUMETRIC FLOW RATE & VELOCITY DATA TAKEN FROM THE PRELIMINARY VELOCITY TRAVERSE.

¹ Reference Conditions (REF) are: 273K, 101.3kPa, without correction for water vapour content.

2 Agreed volumetric flow rate with the EPA (this result was not measured by Exova as part of the monitoring campaign).

-

Limit

179800

1281.08

39.80

7.8125.52 g/hr 3150

0.071

20mg/m³

ng/m³

0.0001 0.05

4134.85

-g/hr

1.10

20.0

0.001

1.24

% v/v

0.79

Medite Europe Ltd, Clonmel

`

g/hr 320.565.42

+/-

Units Result

Concentration

0.0007

MU

0.01

0.0018

mg/m³ 0.05 -

g/hr

g/hr

0.1

Limit

+/-

0.04

mg/m³

Executive Summary

0.29 0.12

Mass Emission

201.96

-

MONITORING RESULTS

EP 35 - Face Dryer Stage 1

0.5 g/hr 11.58 -

2399.4

g/hr

-

Dioxins & Furans Upper Limit (worst case where <LOD = LOD)

0.001 0.17

Units

0.0003 0.053

mg/m³

14.70 100 6008.4

-

877.7

Result Limit

37.09

µg/hr

-

mg/m³

MU

0.0002

m³/hr

18.58

174540

m³/hr

mg/m³

mg/m³

20.80

7819

1.06

200.81mg/m³

g/hr

0.070 0.20.01

1.96 130 127.79 317.14

153.89

-12.8m/s

(Page 2 of 7)

0.95 600

% v/v

10.66

162000

% v/v

°C

g/hr

Volumetric Flow Rate (ACTUAL)

0.246

Volumetric Flow Rate (REF)

mg/m³

8424

-

-

CAT-RT (Version BO)

Page 4 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 7 of 83

Parameter

R1 - -

R1 - -

R1 - -

R1 - -

R1 - -

(NATO) R1 - -

R1 - -

R1 < <

R1 - -

R1 - -

R1 -

R1

All results are expressed at the respective reference conditions.

Isocyanates mg/m³ 0.01 g/hr 1.06 27/07/2016 09:55 - 10:25 30

Dioxins & Furans

Heavy Metals

09:20 - 09:50

0.25

Date(s)

Mass Emission

g/hr

27/07/2016

µg/hr

127.79

39.80

mg/m³

ng/m³

% v/v

15:31 - 16:00

Velocity & Volumetric Flow Rate 26/07/2016

0.0370.0002

(Page 3 of 7)

0.29

Mercury

mg/m³

Units

Medite Europe Ltd, Clonmel

MONITORING DATE(S) & TIMES

mins

Concentration

27/07/2016

Sampling

877.74

37.1Condensable VOCs

EP 35 - Face Dryer Stage 1

26th - 27th July 2016

Executive Summary

Sampling

Times

g/hr

27/07/2016

10:35 - 11:35

09:20 - 09:50

6008.4

mg/m³ 0.17

10:35 - 11:35

mg/m³

60

10:35 - 11:35

g/hr

0.0011

g/hr

27/07/2016

27/07/2016

1

0.0018

25.5 4134.9 27/07/2016

30

08:40 - 09:10

Oxides of Nitrogen (as NO₂)

60Cadmium & Thallium

36026/07/2016

Formaldehyde mg/m³ g/hr

60

11:00 - 17:00

mg/m³

Units

Total Particulate Matter 5.42

g/hr 30

30

Duration

26/07/2016

g/hr

19.63

Carbon Monoxide

0.79

26/07/2016

200.811.24 15:31 - 16:00

Oxygen

26/07/2016mg/m³

g/hrmg/m³

15:31 - 16:00

30

30

30

CAT-RT (Version BO)

Page 5 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 8 of 83

Standard Operating Conditions

Value

Medite Europe Ltd, Clonmel

Feedstock (if applicable)

Process Status

Parameter

Visible

100 % of capacity

Woodchip

Fuel

(Page 4 of 7)

Executive Summary

PROCESS DETAILS

EP 35 - Face Dryer Stage 1

26th - 27th July 2016

Abatement System

Abatement System Running Status

Plume Appearance

Cyclone

Capacity (of 100%) and Tonnes / Hour

Continuous or Batch Process

N/A

On

Continuous

Drying Process

CAT-RT (Version BO)

Page 6 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 9 of 83

0.0011 ng/m³

Isocyanates

CAT

CAT-TP-05 YesEN 14790

1

0.0065 mg/m³

Dry Paramagnetic Cell by Horiba PG-350ECATOxygen

CAT-TP-05

NDIR by Horiba PG-350E

ANALYSIS LABORATORIES

Chemiluminescence by Horiba PG-350E

Deviation

0.1 % v/v

EN 15058

0.41 mg/m³CAT-TP-39

CAT

CAT Yes

Yes

EN 14789 CAT-TP-39 Yes

All

Scientific Analysis Laboratories Ltd (SAL)

RPS Laboratories Ltd (RPS)

Yes

(with short name reference as appears in the table above)

Exova Catalyst (CAT)

ISO 17025 Accreditation Number: 0605

0.1 %

Gravimetric

US EPA CTM36

Water Vapour

Yes

Yes

EN 14792

Yes

Dioxins & Furans CAT

IC

Total Particulate Matter EN 13284-1

CAT-TP-19

CAT

Yes

Yes

Yes

SOP 1C

HPLC

0.54 mg/m³

ISO 17025 Accreditation Number: 4279

ISO 17025 Accreditation Number: 1549

Oxides of Nitrogen (as NO₂)

Yes

Carbon Monoxide

Yes

CAT-TP-17

CAT Yes

CAT SAL

Yes

Analytical

TechniqueProcedure

Heavy Metals

YesCAT-AP-05CAT

Yes SAL

Yes

OX-IR

Analytical

M112

Technical

Mercury

ICP-MS

CAT-TP-03

EP 35 - Face Dryer Stage 1

Yes CATEN 14385

US EPA M316

(Page 5 of 7)

Testing ISO

Cadmium & Thallium

Yes

Standard

Yes

Yes CAT

CAT

CAT-TP-01

EN 1948

Lab

Yes

CAT-TP-07

Yes

Yes

GC-HRMS

ISO

Lab

Yes 0.027 mg/m³

CAT

Executive Summary

Testing

0.004 mg/m³

CAT

Yes

SALOX-IR

Analysis

CAT-TP-23In House

Analysis

17025 Analysis

RPS

RPS

CAT-TP-06

EN 14385

Yes

Yes

ICP-MS

Monitoring

CAT

Parameter

Procedure

CAT-TP-06

Yes

0.001 mg/m³

Condensable VOCs

0 mg/m³

LOD

Yes

CAT-TP-06 Yes

MID 14385

Medite Europe Ltd, Clonmel

Gravimetric

MCERTS

17025

Testing

0.21 mg/m³

CV-AFS

RPS

(Average)

M31

M31

Formaldehyde

Yes

26th - 27th July 2016

Ratio highest to lowest velocities between 3 and 5 : 1.

0.027 mg/m³

CAT-TP-39

MONITORING & ANALYTICAL METHODS

1 The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

SUMMARY OF SAMPLING DEVIATIONS

Parameter Run

All

M119

CAT-RT (Version BO)

Page 7 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 10 of 83

Duct Characteristics Location of Sampling Platform

Platform Details

Sampling Location / Platform Improvement Recommendations

EN 15259 Homogeneity Test Requirements

No

-

Parameter

There are no obstructions present which hamper insertion of sampling equipment

-

m

Yes

Yes

SUITABILITY OF SAMPLING LOCATION

Executive Summary

cm

-

Permanent

Platform has 2 levels of handrails (approx. 0.5m & 1.0m high)

-

Sufficient working area to manipulate probe and operate the measuring instruments

Type

2.20

Width

Sample Port Size

There is no requirement to perform a EN 15259 Homogeneity Test on this Stack.

Circular

Value

Vertical

No

Safe Access Available

(Page 6 of 7)

Permanent / Temporary Platform

Inside / Outside

General Platform Information

Platform has vertical base boards (approx. 0.25m high)

Units

Outside

Yes

24

The sampling location does not meet all of the Flow Criteria requirements in the EPA Guidance Note AG1 and EN 15259.

Area

m

3.80

Orientation of Duct

Irish EPA Technical Guidance Note AG1 / EN 15259 Platform Requirements

Yes

Platform has chains / self closing gates at top of ladders

Value

Easy Access Available

Depth

Port Depth

Yes

4" BSP

Value

CAT-RT (Version BO)

Page 8 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 11 of 83

PLANT PHOTOS

(Page 7 of 7)

Photo 2

SAMPLE POINTS

Photo 1

Photo 4Photo 3

Executive Summary

where = isokinetic point sampled at

= isokinetic point not sampled at

= combustion gases sample point

= non-isokinetic sample point Line A

Line B

A1

A3

A2

A6

A5

A4

B3 B2 B1

B6 B5 B4

CAT-RT (Version BO)

Page 9 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 12 of 83

APPENDIX 1 - Stack Emissions Monitoring Personnel, List of Equipment & Methods and Technical Procedures Used

APPENDIX 2 - Summaries, Calculations, Raw Data and Charts

APPENDICES

APPENDIX CONTENTS

CAT-RT (Version BO)

Page 10 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 13 of 83

Bioaerosols Temperature Logger -

Electronic Refrigerator -

Servomex 4900

-

-

Stopwatch

Mercury

-

-

CAT 3.59

SELECT FTIR

SELECT Horiba Model (2)

MM 10 1074 TE1 TE2 TE3 TE4

Technician James Magann MCERTS Level 1 MM 15 1330 TE1

CAT 39.9

Position

Digital Temperature Meter

Instrumental Analysers

Oven Box (1)

CAT 3.97

METHODS & TECHNICAL PROCEDURES USED

CAT 7.23

Eco Physics CLD 822Mh

CAT-TP-39

CAT-TP-39

MID 14385

EN 14385

EN 1948

Stack Thermocouple (1)

Gasmet Sampling SystemCAT 5.51

ABB AO2020-URAS26

Condensable VOCs

CAT 3.97-

-

CAT 21S.46

Miscellaneous Items

Oxides of Nitrogen (as NO₂)

Heated Probe (3) -

CAT 6.1

Bernath 3006 FID -

-

- 1m Heated Line (2)Heated Probe (2)

Equipment Type

Control Box DGM (2)

-

John Glennon MCERTS Level 2

Mass Flow Controller (2) CAT 6.21

Technical Endorsements

Team Leader

Equipment Type

MCERTS Number

Equipment I.D.

STACK EMISSIONS MONITORING PERSONNEL

APPENDIX 1

EN 14789

Heavy Metals

Mass View (1) -

20m Heated Line (2)

EN 15058

Parameter

Total Particulate Matter

EN 14385

Tubes Kit Thermocouple -

Carbon Monoxide

EN 14790

US EPA CTM36

-

SELECT Logger 2 -

Dual Channel Heater Controller -

CAT-TP-39

Isocyanates

Water Vapour

15m Heated Line (1)

CAT 17.10

Formaldehyde

CAT 4.491

-

Umbilical (2) Servomex 5200MP

Oxygen

Stack Thermocouple (2)

Equipment I.D.

1m Heated Line (3)

Control Box DGM (1)

CAT 4.605

Extractive Sampling

LIST OF EQUIPMENT

MCERTS Accreditation

Single Channel Heater Controller

CAT-TP-01

Barometer

Digital Manometer (2)

Umbilical (1)

Box Thermocouples (2)

Box Thermocouples (1)

-

Stack Thermocouple (3)

CAT 20.71

-

EN 13284-1

Technical ProcedureStandard

Heated Probe (1)

-

-

CAT 12.105

CAT 3.59

-

Mass View (2)

CAT 12.84

-

CAT 4.705

5m Heated Line (1) -

JCT JCC P1 Cooler

CAT 13.27

Mass Flow Controller (1)

500g / 1Kg Check Weights CAT 17.10

Last Impinger Arm CAT 4.404

Callipers

- 20m Heated Line (1)

S-Pitot (2) CAT 21P.92

SELECT Logger 1

Cadmium & Thallium

Site Balance

M&C PSS

Dioxins & Furans

CAT 20.71

Laboratory Balance CAT 1.18 / 1.18a

Tape Measure CAT 16.95

Equipment I.D.

-

CAT 14.53

-

S-Pitot (1)

L-Pitot

-

CAT-TP-19

CAT-TP-07

CAT-TP-06

CAT-TP-06

CAT-TP-06

CAT-TP-23

CAT-TP-05

CAT-TP-17

In House

Horiba PG-350E Digital Manometer (1)

Oven Box (2)

1m Heated Line (1)

Name

-

CAT 23.26

EN 14792

US EPA M316

Equipment Type

CAT-RT (Version BO)

Page 11 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 14 of 83

General Stack Details

Stack Gas Composition & Molecular Weights

CO₂ (Estimated)

O₂

Moisture (H₂O)

Where: p = M / 22.41

pi = r x p

Calculation of Stack Gas Densities

Where: P STD = sum of component concentrations, kg/m³ (not including water vapour)

P STW = sum of all wet concentrations / 100 x density, kg/m³ (including water vapour)

P Actual = P STD x (TSTP / (PSTP)) x ((Pstatic + Pb) / Ta)

P ActualW (at each sampling point) = P STW x (Ts / Ps) x (Pa / Ta)

Calculation of Stack Gas Volumetric Flowrate, Q

PRELIMINARY STACK SURVEY: CALCULATIONS

Stack Diameter / Depth, D

Gas Volumetric Flowrate (from Traverse)

162000

kg/m³

-

Mass

Component

m³/hr

Result

°C

Units

Pa

Fraction

Density

Dry

0.08565

20.80 32.00

Conc

132.7

Molar Conc

3.80

mStack Width, W

Stack Area, A

-

Volume

kPa

kPa

0.84

Value

2.20

100.9

Average Stack Gas Temperature, Ta

0.010

°C

Average Stack Static Pressure, Pstatic

m³/hr

REF ¹

1.219

Dry Density (Actual), P Actual

m³/hr

Gas Volumetric Flowrate (STP, Dry)

Gas Volumetric Flowrate (Actual)

kg/m³

20.0

Average Barometric Pressure, Pb

m

Actual

kg/m³

0.7914 28.01

101.3

Result

1.9635

Stack Details (from Traverse)

APPENDIX 2

0.05

Units

Average Pitot Tube Calibration Coefficient, Cp

ppm kg/m³

Average Stack Gas Pressure

Conc

10.66

Conc

M

Wet

r% v/v

kg/m³

m³/hr

Total Pressure

Average Wet Density (Actual), P ActualW

10.66

79.14 0.98913

1.287

70.71

Dry Density (STP), P STD

18.02

Determinand

0.0006

20.0

100.9

Temperature

N₂

1.4277 0.29696-

Units

0.00118

Gas Volumetric Flowrate (STP, Wet)

Moisture

kPa

0.1066

18.58

p pi

-

1.2498

44.01

144737

-

-

0.2080

-0.0

% v/v

Units

10.66

kg/m³ 1.236

Duct gas flow conditions

162000

174540

1.195

Wet Density (STP), P STW

-

Gas Volumetric Flowrate REF ¹

%

0.8037

0.06

CAT-RT (Version BO)

Page 12 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 15 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

- -

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

APPENDIX 2

877.7

mg/m³ 5.42

Run 1

Maximum

mg/m³ 0.77

A3

Positioning of Filter

Mean

320.6

1.08 1.08

320.6

±% v/v

1 / 2

Number of Sampling Points Used 1 / 12

Titanium

Filter Housing Material Borosilicate Glass

Probe Material

Parameter Units

Run 1

Water Vapour

Concentration

Mass Emission

Standard

47mm Glass Fibre

0.77

Parameter

EN 13284-1

Sample Point I.D.'s

10.11

Number of Sampling Lines Used

CAT-TP-01

% v/v

Value

g/hr 877.7

TOTAL PARTICULATE MATTER: RESULTS SUMMARY

Filter Size and Material

Out Stack

Technical Procedure

Parameter Units

Uncertainty ±g/hr

Medite Europe Ltd, Clonmel

Mean

10.11

EP 35 - Face Dryer Stage 1

Parameter

Concentration

5.42

Blank 1

Uncertainty

Uncertainty ±mg/m³ 1.96 1.96

Units

CAT-RT (Version BO)

Page 13 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 16 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

g/gmol 28.84

34.97

0.3592

761.3

g/gmol 27.75

-

0.06

3563.6

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

Bwo = Vwstd / (Vmstd + Vwstd) 0.1011

N/A

N/A

-

Ps = (Pb + (Pstatic / 13.6) 755.5

N₂

- N/A

No

Pitot tube velocity constant, Kp

Average pressure drop across orifice, ∆H

Average stack gas temperature, Ts

46.9

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

Conversion factor (K/mm.Hg), Cf

Total mass collected in impingers (silica trap)

mmHg

g

mmHg

6.01

°C 57.0

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps)) 15.62

mm

m³/min

min 30

m³/min 2634.4

Area of stack, As m²

%

Average of velocity heads, ∆Pavg mmH₂O

Total sampling time, q

3.80

Qa = (60)(As)(Vs)

Run 1

-

0.6666

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100)

% v/v

0.6534

% v/v

20.80

Velocity of stack gas, Vs

Velocity pressure coefficient, Cp

g

TOTAL PARTICULATE MATTER: ISOKINETIC SAMPLING CALCULATIONS

Test Units

Total mass collected in impingers (liquid trap)

9.7

17.97

4.24

28.34

m³/min

99.7

m/s

-

m³/min

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

0.9310

10.11

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂)

Stack static pressure, Pstatic

N/A

-

% v/v

% v/v

17.3

Barometric pressure, Pb

53.0

Nozzle diameter, Dn

mmH₂O

0.0660

Volume of gas sample through gas meter, Vm m³

Gas meter correction factor, Yd

43.3g

N/AVmstd@X%oxygen = (Vmstd) / (O₂REFd)

N/A

-

Vmstw = (Vmstd)(100/(100 - Rwv))

% v/v 20.86

% wet oxygen measured in gas stream, ACT%O₂w

0.84

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273)

-78.2

0.5873

Average square root of velocity heads, √∆P

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw)

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

Vwstd = (0.001246)(Vlc)

Average dry gas meter temperature, Tm °C

Total mass of liquid collected, Vlc

% v/v

APPENDIX 2

% v/v

% v/v

mmH₂O

% oxygen reference condition, REF%O₂ % v/v N/A

% dry oxygen measured in gas stream, ACT%O₂d

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

Vmstw@X%oxygen = (Vmstw) / (O₂REFw)

mm²

Total

2930.6

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273)

79.14

√mmH₂O

Nozzle area, An

N/A

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd) m³/min N/A

10.11

CAT-RT (Version BO)

Page 14 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 17 of 83

Sample Runs

Filter I.D. Number

Probe Rinse I.D. Number

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

Filter I.D. Number

Probe Rinse I.D. Number

Start Probe Rinse Mass

0.00021

5.42

Sampling Device

3.54

0.77

0.00333

-

2.94040

Start Filter Mass

3.18239

-

Total Mass on Filter

mg/m³

0.21

0.14667

Total Mass on Filter

End Filter Mass

-

Parameter

-

End Probe Rinse Mass

47-32937

g

Units

g

g

0.6534

Total Mass in Probe Rinse

09:20 - 09:50

Average Volume Sampled (REF)

PR-47-32938

Start Filter Mass

g

0.15146

0.15479

PR-47-32937

mg/m³

Balance Uncertainty / LOD

Calculated Concentration

TOTAL PARTICULATE MATTER: SAMPLING DETAILS

Balance Uncertainty / LOD

47-32938

mg 0.50

0.21

Calculated Concentration

g

3.18260

0.14625

-

Blank Dates -

mg/m³

Total Mass Collected

Parameter Units

Sampling Dates

ISO

End Probe Rinse Mass

End Filter Mass

Sampling Times

Blank 1

Run 1

APPENDIX 2

-

g

g

27/07/2016

0.6534

g

-

Total Mass in Probe Rinse

Start Probe Rinse Mass

g 0.00042

Volume Sampled (REF) m³

0.00008

mg

g

mg/m³

g

g

2.94032

Total Mass Collected

27/07/2016

CAT-RT (Version BO)

Page 15 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 18 of 83

Sample Runs

MU Acceptable

Test Conditions Units

Allowable Weighing Uncertainty

95 - 115

180

0.27

Weighing Uncertainty Criteria

160

ELV [Daily ELV for IED] mg/m³ 35.00

Weighing Uncertainty Acceptable

Isokinetic Variation

Yes

Run 1

TOTAL PARTICULATE MATTER: QUALITY ASSURANCE

No

%

Yes

± mg/m³

Run 1

Post-Sampling Leak Rate

Leak Test Results

Yes

-

0.41

150

Mean Sampling Rate l/min 20.69

Leak Test Acceptable

l/min 0.30

Allowable Leak Rate

Run 1

Measurement Uncertainty (MU)

-

Silica Gel (Concurrent Water Vapour) Units

Allowable Isokinetic Range %

Allowable MU

(PAGE 1 OF 2)

Units

Units

Filter Temperatures

Units

Yes

Units Run 1

Ambient Temperature Recorded? -

- Yes

Run 1

Are Water Droplets Present

l/min

°C

mg/m³ 1.75

Water Droplets

%

Run 1

20

°C

Yes

APPENDIX 2

Isokinetic Criterion Compliance

Units

Pre-Sampling Leak Rate l/min 0.14

Overall Weighing Uncertainty

Less than 50% Faded

Units

± mg

Run 1

-

°C

%

99.7%

10.7

0.41

%

Isokineticity Acceptable

Maximum Filter Temperature

Pre-Conditioning Temperature

Post-Conditioning Temperature

Run 1

Overall Weighing Uncertainty

MU (Concurrent Water Vapour)

CAT-RT (Version BO)

Page 16 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 19 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

Yes

Post-Sampling Leak Rate l/min 0.18

Leak Test Acceptable

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Ratio highest to lowest velocities between 3 and 5 : 1.

Blank 1

0.40

Units Blank 1

mg/l

-

Run Number

-

Yes

3.5

0.12

(PAGE 2 OF 2)

Validity of Blank vs ELV

Acetone / Water Rinse Value

mg/m³

10

Allowable Leak Rate

Allowable Blank

Units

Nature of Deviation

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

2.7

Pre-Sampling Leak Rate

l/min

l/minExpected Sampling Rate 20.00

Acetone / Water Rinse Blank Units Blank

Blank Acceptable

Leak Test Results

APPENDIX 2

TOTAL PARTICULATE MATTER: QUALITY ASSURANCE

Allowable Blank

mg/l

-

Yes

l/min

Blank Acceptable

CAT-RT (Version BO)

Page 17 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 20 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Mass of Particulate

Uncollected Mass

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Mass of Particulate

Uncollected Mass

Sampled Volume (STP)

Leak

Mass of Particulate

Uncollected Mass

Sampled Volume (STP)

Leak

Mass of Particulate

Uncollected Mass

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Oxygen Correction Part of MU Budget

Measured Quantities

-

mg

%

Units

- N/A

Overall MU For O₂ Measurement

mg/m³

18.6

3.540

1.53

≤1%

mg/m³

-

0.50

0.4418

Run 1

≤2%

% v/v

Symbol Units

Uncertainty in Measurement Units Sensitivity Coefficient

%

mg/m³

mg/m³

0.2143

9.23

uVm m³

Measured Quantities Symbol

m um

0.5ρm 100.7

mg/m³

Measured Quantities

% 1.45

N/A

N/A

1.96

0.045

kPa

1.45

0.0Hm

Units

% N/A

Parameter Units

N/A

-uL %

%

≤2%

%

mg/m³ 0.142

3.54

mg/m³

Run 1

uHm

%

Uncertainty as a Percentage

N/A

36.2

1.0

0.29

-

Run 1 Requirement of Standard

Run 1

2.00

Measured Quantities

uUCM mg -

Units

0.69

%

Measured Quantities

%

Vm

0.5873

Symbol

uTm

Run 1

36.2

1.53

mg/m³

K 2.0

0.6666

L

% 0.61

Run 1

1.96

1.00

UCM

0.0454

<5% of ELV

Run 1

mg

APPENDIX 2

TOTAL PARTICULATE MATTER: MEASUREMENT UNCERTAINTY CALCULATIONS

Value Standard uncertainty

0.0133

Lr mg

1.01

290.3

L

%

mg/m³

0.50

UCM

Units Run 1

Tm

Vm

% v/v

uρm

≤1%

Uncertainty in Result

mg/m³ 0.51

≤1%

% 1.00

0.14

CAT-RT (Version BO)

Page 18 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 21 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

- -

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

In HouseStandard

2399.4

Technical Procedure CAT-TP-23

Units

2399.4

CONDENSABLE VOCS: RESULTS SUMMARY

6008.4

1.08

Units

Medite Europe Ltd, Clonmel

47mm Glass FibreFilter Size and Material

Uncertainty

Units

ISO 17025 Accredited Analysis?

±mg/m³

Maximum

12/08/2016

31.19

Mean

31.19

Concentration

Titanium

Parameter

Name of Analytical Laboratory

Number of Sampling Lines Used

Yes

EP 35 - Face Dryer Stage 1

OX-IR

1.08

1 / 2

Filter Housing Material

APPENDIX 2

Positioning of Filter

Borosilicate Glass

Parameter

Absorption Solution HPLC Grade Water

Parameter

Number of Sampling Points Used 1 / 12

Sample Point I.D.'s

10.11

±% v/v

37.09

Run 1

14.70

g/hr

Out Stack

14.70

6008.4

Impinger Material

Run 1

10.11

Blank 1

Probe Material

Parameter

±g/hr

Concentration mg/m³

Mass Emission

A3

Uncertainty

Analytical Laboratory's Procedure

Value

Mean

mg/m³ 37.09

Uncertainty

Borosilicate Glass

SAL

Date of Sample Analysis

Water Vapour % v/v

CAT-RT (Version BO)

Page 19 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 22 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

Total mass collected in impingers (silica trap) g

Total mass of liquid collected, Vlc

0.6534

15.62

Nozzle area, An 28.34

N/A

g

-

% v/v

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

10.11

% v/v

0.1011

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw)

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps))

Average square root of velocity heads, √∆P

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

3563.6

N₂

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

Vwstd = (0.001246)(Vlc)

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂) g/gmol 28.84

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273)

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd)

20.80

minTotal sampling time, q

27.75

% v/v

%

Volume of gas sample through gas meter, Vm

-

m³ N/A

0.06

79.14

% v/v N/A

N/A

-

Qa = (60)(As)(Vs) m³/min

Velocity of stack gas, Vs

Bwo = Vwstd / (Vmstd + Vwstd)

-

17.97

Area of stack, As

-

N/A

57.0

Velocity pressure coefficient, Cp

3.80

6.01Nozzle diameter, Dn

4.24

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100)

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

0.6666

Pitot tube velocity constant, Kp

N/A

No

2930.6

Conversion factor (K/mm.Hg), Cf

mm²

-

°C

Vmstw = (Vmstd)(100/(100 - Rwv))

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

mmHg

Average dry gas meter temperature, Tm

Ps = (Pb + (Pstatic / 13.6)

% v/v N/A

53.0

Total

755.5

20.86

Average pressure drop across orifice, ∆H

17.3

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

% v/v

Stack static pressure, Pstatic

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273)

0.0660

mmHg

Barometric pressure, Pb

Run 1

g

-Gas meter correction factor, Yd

mmH₂O

CONDENSABLE VOCS: ISOKINETIC SAMPLING CALCULATIONS

43.3

761.3

-78.2

9.7

Test Units

0.9310

Total mass collected in impingers (liquid trap)

APPENDIX 2

mmH₂O

10.11

% v/v

% oxygen reference condition, REF%O₂

N/A

Vmstw@X%oxygen = (Vmstw) / (O₂REFw)

2634.4

m³/min N/A

m³ 0.5873

% v/v

46.9

g/gmol

% wet oxygen measured in gas stream, ACT%O₂w % v/v

% dry oxygen measured in gas stream, ACT%O₂d

m³/min

m³/min

m³/min

Average stack gas temperature, Ts

0.3592

30

0.84

mmH₂O

√mmH₂O

mm

m/s

°C

34.97

99.7

Average of velocity heads, ∆Pavg

CAT-RT (Version BO)

Page 20 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 23 of 83

Sample Runs

-

-

-

-

-

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

-

-

-

-

µg/ml

27/07/2016

µg/ml

Parameter

Laboratory Result for Back Impinger

Parameter

67.00

Volume Sampled (REF)

Sampling Device

mg/m³

0.6534

ISO

246.7

09:20 - 09:50

Volume in Front Impingers

Run 1

-

Volume in Impingers ml

APPENDIX 2

µg/ml

24232.4

Calculated Concentration mg/m³ 31.19

-

Laboratory Result for Impingers

µg

7703.5

Volume in Back Impinger ml

304.2

Units

Average Volume Sampled (REF)

Total Mass Collected

µg

108.5

Mass in Back Impinger

ml

67.00

71.00

µg

Mass in Front Impingers 16528.9

Laboratory Result for Front Impingers

Calculated Concentration

Blank Dates

20381.4

-

CONDENSABLE VOCS: SAMPLING DETAILS

Sampling Times

Sampling Dates

37.09

27/07/2016

Units

Total Mass Collected

m³ 0.6534

µg

-

Blank 1

CAT-RT (Version BO)

Page 21 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 24 of 83

Sample Runs

0 0 0 0

Run 1

Silica Gel (Concurrent Water Vapour)

Yes

-

% Yes

Units

-

Units

%

Run 1

Units

Test Conditions

Absorption Efficiency Acceptable

Allowable Leak Rate

99.7

%

%

l/min 0.14

Are Water Droplets Present

20.69

MU Acceptable

10.7

Isokinetic Criterion Compliance Units

95 - 115

Allowable MU

Run 1

Maximum Filter Temperature

Leak Test Acceptable -

Allowable Isokinetic Range %

150

Yes

MU (Concurrent Water Vapour)

Ambient Temperature Recorded?

Isokineticity Acceptable

Post-Sampling Leak Rate l/min

%

Less than 50% Faded

Run 1

N/A

°C

Yes

Pre-Sampling Leak Rate

Isokinetic Variation

N/A

Water Droplets

20

Measurement Uncertainty (MU)

Absorption Efficiency

Units

Yes

-

CONDENSABLE VOCS: QUALITY ASSURANCE

(PAGE 1 OF 2)

Leak Test Results Units

Run 1

Allowable Absorption Efficiency

% 68.2

-

Run 1

Run 1

%

Filter Temperatures

Units

No

0.41

APPENDIX 2

0.30

Mean Sampling Rate

Run 1Absorption Efficiency

l/min

Units

l/min

CAT-RT (Version BO)

Page 22 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 25 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

20.00Expected Sampling Rate l/min

APPENDIX 2

Pre-Sampling Leak Rate

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Allowable Leak Rate

Blank 1

10.0

Blank Acceptable - No

Ratio highest to lowest velocities between 3 and 5 : 1.

l/min 0.12

mg/m³

Validity of Blank vs ELV

0.40l/min

Nature of Deviation

Post-Sampling Leak Rate l/min

Units Blank 1

0.18

Allowable Blank

Units

Run Number

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

Leak Test Acceptable - Yes

CONDENSABLE VOCS: QUALITY ASSURANCE(PAGE 2 OF 2)

Leak Test Results

CAT-RT (Version BO)

Page 23 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 26 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

N/A

Units Run 1

Overall MU For O₂ Measurement

Oxygen Correction Part of MU Budget

Measured Quantities

%

mg/m³

mg/m³

%

0.5873

290.3

m³0.6666

0.5

0.69

1.00

-

% v/v N/A

% N/A

-

%

Sensitivity Coefficient

Vm

≤2%

0.3105

10.00

10.00

Measured Quantities

39.6

63.15

Run 1

≤1%

%

-

Measured Quantities

7.54

Units

Measured Quantities

mg/m³

% 0.50

1.00

mg/m³

Run 1

N/A

2.00

L

0.9724

Run 1

Tm

Symbol

CONDENSABLE VOCS: MEASUREMENT UNCERTAINTY CALCULATIONS

uVm

uTm K 2.0

mg/m³ 3.709

mg/m³

uHm

uρm

Run 1

0.0

%

% N/A

%

mg/m³ 3.709

14.70

Uncertainty in Result

% v/v

%

L

% 39.6

1.45

14.70mg/m³

mg/m³ N/A

Symbol

3.85

Uncertainty as a Percentage

20.3

Units

Symbol Units

Parameter Units Run 1

Run 1

No Requirement

Lr

Units

APPENDIX 2

1.0

Vm

Measured Quantities

-

Hm

mg/m³

1.00

Uncertainty in Measurement Units

0.311

%

uLr

0.0133

uL

ρm 100.7

Value Standard uncertainty

Run 1

1.45

≤1%

≤2%

Requirement of Standard

≤1%

%

kPa

Lr

CAT-RT (Version BO)

Page 24 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 27 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

< <

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

1.15

0.1

Run 1

Impinger Material Borosilicate Glass

Concentration

0.1

Name of Analytical Laboratory RPS

mg/m³

Borosilicate Glass

Nitric Peroxide

Sample Point I.D.'s

Uncertainty

1.15

Maximum

0.0011

Absorption Solution

47mm Quartz Fibre

Uncertainty

EN 14385

ISO 17025 Accredited Analysis? Yes

Value

Date of Sample Analysis 09/08/2016

10.88

Units

M31

Number of Sampling Points Used

Out Stack

±% v/v

Filter Size and Material

±mg/m³

Filter Housing Material

Units

Number of Sampling Lines Used 1 / 1

Probe Material Titanium

0.0008

Parameter

Mean

Technical Procedure

Mean

% v/vWater Vapour

Parameter

0.0003

APPENDIX 2

Run 1

±g/hr

CADMIUM & THALLIUM: RESULTS SUMMARY

1 / 1

0.0011

Uncertainty

Mass Emission

0.0003

mg/m³

A3

Positioning of Filter

Analytical Laboratory's Procedure

Standard

CAT-TP-06

Units

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

10.88

Parameter

g/hr

0.0008

Parameter

0.2

Concentration

0.2

Blank 1

CAT-RT (Version BO)

Page 25 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 28 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Velocity of stack gas, Vs

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

Barometric pressure, Pb

Total mass collected in impingers (liquid trap)

Ps = (Pb + (Pstatic / 13.6)

47.0

mmH₂O 17.28

5.0

mmH₂O -78.2

m³/min

Nozzle diameter, Dn

Total sampling time, q

2877.9

Area of stack, As m² 3.80

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) m³/min

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd)

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

Total mass of liquid collected, Vlc

Volume of gas sample through gas meter, Vm

Gas meter correction factor, Yd

Test

% wet oxygen measured in gas stream, ACT%O₂w % v/v

15.34

4.16

Conversion factor (K/mm.Hg), Cf

755.5

Total mass collected in impingers (silica trap)

g/gmol

N/A

% v/v

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

1.1309

No

m³/min

°C 21.4

20.80

m³ 0.1381

min 60

mmHg

m/s

% v/v 10.88

-

10.88

98.6

761.3

% oxygen reference condition, REF%O₂

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

Average stack gas temperature, Ts °C

g 105.8

mmHg

mm

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw) m³/min N/A

g/gmol

N/A

0.1088

Total

Stack static pressure, Pstatic

N₂

% v/v

79.14

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100)

Vmstw = (Vmstd)(100/(100 - Rwv))

28.84

m³/min

% v/v

0.84-

% v/v

Vmstw@X%oxygen = (Vmstw) / (O₂REFw)

Run 1Units

APPENDIX 2

CADMIUM & THALLIUM: ISOKINETIC SAMPLING CALCULATIONS

Bwo = Vwstd / (Vmstd + Vwstd)

-

g

Average pressure drop across orifice, ∆H mmH₂O

0.9310

g

110.8

N/A

20.86

1.3020

Average dry gas meter temperature, Tm

-

N/A

Nozzle area, An

34.97

% dry oxygen measured in gas stream, ACT%O₂d

-

1.2690

N/A

28.34

% v/v

m³ N/A

N/A

% v/v

Average of velocity heads, ∆Pavg

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps))

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273)

6.01

3499.6

-

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

Vwstd = (0.001246)(Vlc)

Velocity pressure coefficient, Cp

%

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂)

2564.8

mm²

N/A

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

Pitot tube velocity constant, Kp -

27.66

% v/v

0.06

0.3592

Qa = (60)(As)(Vs)

Average square root of velocity heads, √∆P √mmH₂O

57.0

CAT-RT (Version BO)

Page 26 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 29 of 83

Sample Runs

Cadmium

-

-

Mass in Back Impinger <

-

-

-

-

Thallium

-

<

Mass in Back Impinger <

-

-

-

-

Cadmium & Thallium Combined

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

Cadmium

<

<

Mass in Back Impinger <

<

<

<

Thallium

<

<

Mass in Back Impinger <

<

<

<

Cadmium & Thallium Combined

<

<

<

0.05

g/hr

µg

mg/m³

-

Calculated Concentration

µg

Total Mass Collected

10:35 - 11:35

0.0007

µg 0.50

Total Mass Collected

Mass in Front Impingers

0.0004

0.46

Calculated Concentration

Sampling Dates

Sampling Device

Total Mass Collected µg

Sampling Times

µg

Reported Concentration

0.0004

0.0004

0.55

µg

0.40

0.04

0.06

0.0008

Run 1

µg

Units

0.89

Mass on Filter / in Rinse µg 0.80

0.01

1.2690

0.01

µg

Total Mass Collected

-

0.0011

mg/m³

mg/m³

0.0008

0.01

mg/m³

g/hr

Blank 1

0.11

Mass on Filter / in Rinse

µg 0.45

µg

0.04

CADMIUM & THALLIUM: SAMPLING DETAILS

mg/m³

Total Mass Collected µg

Calculated Concentration

mg/m³

ISO

Reported Concentration

Reported Concentration

Mass on Filter / in Rinse

Total Mass Collected µg

-

27/07/2016

Volume Sampled (REF)

27/07/2016

Reported Concentration

Mass in Front Impingers

APPENDIX 2

Mass Emission

µg

mg/m³

Calculated Concentration

µg

mg/m³ 0.0004

µg

Average Volume Sampled (REF)

Mass in Front Impingers

Blank Dates -

Parameter

0.0011

Mass in Front Impingers

µg

Reported Concentration

Parameter

Units

0.01

0.08

0.0007

Mass Emission

mg/m³

Calculated Concentration

Reported Concentration mg/m³

0.0004

1.2690

0.99

Mass on Filter / in Rinse µg 0.40

mg/m³

Calculated Concentration mg/m³ 0.0004

1.35

CAT-RT (Version BO)

Page 27 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 30 of 83

Sample Runs

Units Run 1

%

Units

Units

Less than 50% Faded

Run 1

% Yes

Silica Gel (Concurrent Water Vapour)

Allowable Isokinetic Range

Exit Temperature Acceptable

l/min

- Yes

Maximum Temperature Recorded 18

% 95 - 115

µg/m³

Isokineticity Acceptable

Isokinetic Criterion Compliance

Maximum Filter Temperature °C

Run 1

- Yes

Yes

Measurement Uncertainty (MU) % 10.6

Isokinetic Variation

Units

180

98.6

Water Droplets Units

5

Run 1

°C

°C 30

Units Run 1

Ambient Temperature Recorded? Yes-

Allowable Detection Limit

-

Allowable Leak Rate

%

APPENDIX 2

0.40

l/min

MU (Concurrent Water Vapour)

Pre-Sampling Leak Rate l/min

20.20

%

20

Leak Test Results Run 1

0.4

Yes

(PAGE 1 OF 2)

µg/m³

Absorption Efficiency

Where the emissions are < 30% of the ELV, MID 14385 does not require the 90% absorption efficiency requirement to be applied

Allowable Absorption Efficiency

0.21

Filter Temperatures

Units Run 1

Units

Post-Sampling Leak Rate

Run 1

l/min

100.0

Run 1

N/A

0.16

Thallium % 100.0

-

Thallium

MU Acceptable

Absorption Efficiency Acceptable

%

-

µg/m³

Run 1

Units

Mean Sampling Rate

Allowable MU

Units

Detection Limit

Cadmium

Are Water Droplets Present

Detection Limit Acceptable

Impingers Exit Temperature

Cadmium

Maximum Allowable Temperature

Leak Test Acceptable

No

-

Test Conditions

N/A

0.4

%

Yes

CADMIUM & THALLIUM: QUALITY ASSURANCE

CAT-RT (Version BO)

Page 28 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 31 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

Allowable Blank

0.40

APPENDIX 2

Blank 1

Pre-Sampling Leak Rate l/min

Leak Test Acceptable

0.0050

Validity of Blank vs ELV Units

mg/m³

l/min 20.00Expected Sampling Rate

Allowable Leak Rate

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

Leak Test Results

Post-Sampling Leak Rate

0.20

Ratio highest to lowest velocities between 3 and 5 : 1.

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

-

0.18

l/min

Nature of Deviation Run Number

CADMIUM & THALLIUM: QUALITY ASSURANCE(PAGE 2 OF 2)

Yes

Yes

l/min

Units Blank 1

Blank Acceptable -

CAT-RT (Version BO)

Page 29 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 32 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

%

- N/A

Units Run 1

% -

1.04 uL

Measured Quantities Requirement of Standard

%

≤1%0.68

2.00

≤2%

%

1.04

≤1%

% 1.00

Run 1

uLr % -

Tm 294.4

uρm

uVm

Run 1 Run 1

ρm

mg/m³ 0.0002

mg/m³ 0.0003

0.0003

L mg/m³ 0.0000

% v/v N/A

- N/A

Overall MU For O₂ Measurement % N/A

% 15.6

mg/m³

Uncertainty as a Percentage

%

Measured Quantities

Uncertainty in Result

Vm 1.3020

0.5

Hm 0.0

CADMIUM & THALLIUM: MEASUREMENT UNCERTAINTY CALCULATIONS

Symbol

Symbol Units

uTm

Uncertainty in Measurement Units

≤2%

≤1%

0.50

Measured Quantities Symbol

kPa

0.0260

Measured Quantities

m³ 0.00

Run 1

1.1309

Oxygen Correction Part of MU Budget

Units Run 1

%

7.50 No Requirement

Vm

K

L

100.7

Measured Quantities Units Run 1

1.00

Sensitivity Coefficient

Units

mg/m³

0.0001

% 30.5

mg/m³ 0.0001

mg/m³ 0.0000

mg/m³ N/A

mg/m³ 0.0000

% N/A

Parameter Units

% 30.5

Lr mg/m³ 0.0001 1.00

Run 1

Standard uncertainty

APPENDIX 2

uHm % v/v 1.0

2.0

Lr

Value

7.50

CAT-RT (Version BO)

Page 30 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 33 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

- -

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

11.6Uncertainty

Units

Nitric Peroxide

Run 1

APPENDIX 2

Date of Sample Analysis

10.88

Uncertainty ±% v/v 1.15 1.15

Borosilicate Glass

Mass Emission g/hr

Blank 1

Mean

Concentration mg/m³

Maximum

Concentration mg/m³

% v/v

Number of Sampling Points Used 1 / 1

0.005

47mm Quartz Fibre

Parameter Units

09/08/2016

39.8

0.246

A3

Parameter

±g/hr

EN 14385

Mean

CAT-TP-06

0.246

Name of Analytical Laboratory RPS

Analytical Laboratory's Procedure M31

ISO 17025 Accredited Analysis? Yes

Titanium

Filter Housing Material Borosilicate Glass

Impinger Material

0.071

HEAVY METALS: RESULTS SUMMARY

Water Vapour

Out Stack

Filter Size and Material

10.88

Parameter

11.6

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

Probe Material

Sample Point I.D.'s

Technical Procedure

Absorption Solution

Positioning of Filter

Value

Parameter Units Run 1

0.005

0.071Uncertainty ±mg/m³

39.8

Number of Sampling Lines Used 1 / 1

Standard

CAT-RT (Version BO)

Page 31 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 34 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Velocity of stack gas, Vs

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

Average of velocity heads, ∆Pavg mmH₂O

Velocity pressure coefficient, Cp

17.28

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd) m³/min

%

N/A

min 60

N/A

4.16

Average stack gas temperature, Ts °C

3.80

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

HEAVY METALS: ISOKINETIC SAMPLING CALCULATIONS

Test Units Run 1

Barometric pressure, Pb 761.3

Gas meter correction factor, Yd

N₂

-

g 110.8

g 5.0

% v/v

m³ 1.2690

m³/min

Vmstw = (Vmstd)(100/(100 - Rwv))

10.88% v/v

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction) -

2564.8

Nozzle area, An mm² 28.34

Bwo = Vwstd / (Vmstd + Vwstd) m³

2877.9

98.6

Vwstd = (0.001246)(Vlc) m³

Total sampling time, q

N/A

-

47.0

% v/v

% wet oxygen measured in gas stream, ACT%O₂w

Conversion factor (K/mm.Hg), Cf

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps)) m/s

m³/min N/AQstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw)

-

Average dry gas meter temperature, Tm °C 21.4

Total mass collected in impingers (silica trap)

No

10.88

Total mass collected in impingers (liquid trap) g

Volume of gas sample through gas meter, Vm

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

N/A

15.34

Nozzle diameter, Dn mm 6.01

0.06

57.0

Pitot tube velocity constant, Kp

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂)

-

0.1381

Total mass of liquid collected, Vlc

0.1088

g/gmol 28.84

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100) g/gmol 27.66

N/A

- 0.84

N/A

Average square root of velocity heads, √∆P √mmH₂O

Qa = (60)(As)(Vs) m³/min 3499.6

Vmstw@X%oxygen = (Vmstw) / (O₂REFw) m³

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

- 0.3592

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273)

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

20.86

20.80

mmHg 755.5

Total % v/v

mmHg

0.9310

% oxygen reference condition, REF%O₂

1.3020

105.8

mmH₂O

% dry oxygen measured in gas stream, ACT%O₂d % v/v

% v/v

APPENDIX 2

% v/v 79.14

% v/v

m³/min

Stack static pressure, Pstatic mmH₂O -78.2

N/A

Area of stack, As

Ps = (Pb + (Pstatic / 13.6)

% v/v N/A

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273) m³ 1.1309

Average pressure drop across orifice, ∆H

34.97

CAT-RT (Version BO)

Page 32 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 35 of 83

Sample Runs

Arsenic

-

-

Mass in Back Impinger <

-

-

-

-

Cobalt

<

<

Mass in Back Impinger <

<

<

<

<

Chromium

-

-

Mass in Back Impinger -

-

-

-

-

Copper

-

-

Mass in Back Impinger -

-

-

-

-

Manganese

-

-

Mass in Back Impinger <

-

-

-

-

Reported Concentration

Volume Sampled (REF)

µg

Total Mass Collected µg 0.56

mg/m³

0.0004

Mass on Filter / in Rinse µg

µg

Units Run 1

Mass on Filter / in Rinse µg

mg/m³ 0.0143

0.07

0.0185

0.0185

Mass in Front Impingers µg 6.86

0.50

Reported Concentration mg/m³ 0.0033

Mass on Filter / in Rinse µg

Mass in Front Impingers µg 0.05

µg

108.00

11.00

4.17Total Mass Collected

Mass Emission

m³ 1.2690

HEAVY METALS: SAMPLING DETAILS

Parameter

0.0033Calculated Concentration mg/m³

0.01

Calculated Concentration mg/m³

Sampling Times

27/07/2016

µg 0.15

Sampling Device - ISO

0.53

Sampling Dates

APPENDIX 2

(PAGE 1 OF 5)

-

4.00

- 10:35 - 11:35

Mass on Filter / in Rinse µg

Mass in Front Impingers

µg

g/hr

Mass Emission

Mass on Filter / in Rinse

µg 0.25

µg

108.26

mg/m³

mg/m³ 0.0004

Mass Emission g/hr 2.99

3.00

0.25

Calculated Concentration

20.32

Mass Emission

µg

Mass in Front Impingers

mg/m³

g/hr

Calculated Concentration

Total Mass Collected µg 23.42

Reported Concentration

µg

mg/m³ 0.0143

Mass in Front Impingers

µg

µg 18.11Total Mass Collected

0.10

0.02

2.31

µgTotal Mass Collected

0.01

Reported Concentration

Calculated Concentration

Mass Emission

Reported Concentration mg/m³

g/hr

g/hr

0.0853

0.0853

13.82

CAT-RT (Version BO)

Page 33 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 36 of 83

Sample Runs (continued)

Nickel

-

-

Mass in Back Impinger <

-

-

-

-

Lead

-

-

Mass in Back Impinger -

-

-

-

-

Antimony

-

<

Mass in Back Impinger <

-

-

-

-

Vanadium

<

<

Mass in Back Impinger <

<

<

<

<

Total Mass Collected

µg 0.25

µgTotal Mass Collected

0.0063

mg/m³

µg

mg/m³

1.06

Run 1

0.1164

18.86

µg

Mass on Filter / in Rinse

g/hr 1.02

0.03

µg 0.01

µg

mg/m³

Mass on Filter / in Rinse

Calculated Concentration

µg

147.76

Mass in Front Impingers

Mass Emission

0.01

mg/m³

0.05

0.40

Mass on Filter / in Rinse µg

0.0003

Calculated Concentration

g/hr

µg

0.14

Mass in Front Impingers

Mass Emission

Reported Concentration

Total Mass Collected

Mass Emission g/hr

0.0008

µg

Mass Emission g/hr

mg/m³

1.00

Calculated Concentration

0.0008

0.05

µg

Mass in Front Impingers

mg/m³

Total Mass Collected

Units

µg 7.00

0.51

µg 147.00

µg 0.43

Calculated Concentration 0.0063

Reported Concentration

8.03

Parameter

APPENDIX 2

HEAVY METALS: SAMPLING DETAILS(PAGE 2 OF 5)

Mass in Front Impingers µg

Mass on Filter / in Rinse

Reported Concentration

1.02

0.01

0.1164

Reported Concentration

0.0003

mg/m³

µg

mg/m³

CAT-RT (Version BO)

Page 34 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 37 of 83

Sample Runs (continued)

Heavy Metals Combined

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

Arsenic

<

<

Mass in Back Impinger <

<

<

<

Cobalt

<

<

Mass in Back Impinger <

<

<

<

Total Mass Collected

µg

Calculated Concentration 0.0004

Mass in Front Impingers µg

µg

Mass on Filter / in Rinse µg

µg

Average Volume Sampled (REF)

0.50

Mass on Filter / in Rinse

0.06

311.80

mg/m³

Blank Dates

1.2690

mg/m³

- 27/07/2016

µg

APPENDIX 2

(PAGE 3 OF 5)

Parameter

Total Mass Collected

HEAVY METALS: SAMPLING DETAILS

0.57

Run 1

mg/m³

UnitsParameter

Reported Concentration

mg/m³

0.50

0.01

0.0004

0.0004

0.02

Calculated Concentration 0.2457

µg

0.04

0.55Total Mass Collected

Reported Concentration

0.2457

µg

µg

Mass in Front Impingers

0.0004mg/m³

Units Blank 1

Reported Concentration

Calculated Concentration mg/m³

CAT-RT (Version BO)

Page 35 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 38 of 83

Blank Runs (continued)

Chromium

<

-

Mass in Back Impinger -

-

-

-

Copper

<

-

Mass in Back Impinger -

-

-

-

Manganese

-

<

Mass in Back Impinger <

-

-

-

Nickel

<

<

Mass in Back Impinger <

<

<

<

Lead

<

-

Mass in Back Impinger -

-

-

-

Antimony

<

<

Mass in Back Impinger <

<

<

<

Vanadium

<

<

Mass in Back Impinger <

<

<

<

0.0005

0.59

Mass in Front Impingers

Mass in Front Impingers µg

mg/m³

0.0003

0.0014

mg/m³

Mass in Front Impingers

Mass on Filter / in Rinse

0.0005

mg/m³

Reported Concentration

mg/m³

µg

0.42

µg

Mass on Filter / in Rinse

µg

Calculated Concentration

0.02

0.0005

HEAVY METALS: SAMPLING DETAILS

mg/m³

Reported Concentration

mg/m³

µg

mg/m³

Mass on Filter / in Rinse

mg/m³

Calculated Concentration

0.07

µg

µg

µg

Calculated Concentration

0.0008

0.04

Reported Concentration

0.40

Total Mass Collected

mg/m³

mg/m³

0.65

0.0005

Reported Concentration mg/m³ 0.0004

µgMass on Filter / in Rinse

0.0004

0.50

Total Mass Collected

Total Mass Collected

Reported Concentration

0.0008

0.04

0.0005

µg

0.60

mg/m³

mg/m³

µg

µg

0.65

µg 0.50

0.0005

µg

µg

0.55

µg 0.18

0.21

0.60

0.01

µg

µg

mg/m³

0.02

Total Mass Collected

Calculated Concentration 0.0003

Mass in Front Impingers

µg

0.01

0.01

0.60

Mass on Filter / in Rinse

Total Mass Collected

µg

APPENDIX 2

µg 1.73

0.99

µg

0.60

Calculated Concentration

0.0014

Mass in Front Impingers

Calculated Concentration

Reported Concentration

µg

1.10

0.01

Total Mass Collected

Units Blank 1

Mass on Filter / in Rinse

Mass in Front Impingers µg 0.04

µg

µg

Calculated Concentration

Mass in Front Impingers µg

µg

0.03

Mass on Filter / in Rinse

(PAGE 4 OF 5)

Parameter

Total Mass Collected

Reported Concentration

CAT-RT (Version BO)

Page 36 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 39 of 83

Blank Runs (continued)

Heavy Metals Combined

-

-

-

Units Blank 1

Calculated Concentration

0.0053

(PAGE 5 OF 5)

Parameter

APPENDIX 2

µg

HEAVY METALS: SAMPLING DETAILS

mg/m³ 0.0053

6.70

Reported Concentration mg/m³

Total Mass Collected

CAT-RT (Version BO)

Page 37 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 40 of 83

Sample Runs

0.4

% N/A <1% Total

% N/A <1% Total

100.0

-

0.4

% 10.6

Arsenic

µg/m³

Chromium

Absorption Efficiency Units Run 1

Vanadium

Detection Limit

Absorption Efficiency Acceptable

µg/m³

20

Pre-Sampling Leak Rate

% N/A <1% Total

Cobalt

0.4

Run 1

90

Units

µg/m³

Units

Run 1

Allowable Detection Limit

MU (Concurrent Water Vapour)

MU Acceptable % Yes

Units

%

Mean Sampling Rate

98.6

%

Nickel

Lead

Chromium %

Arsenic

l/min 0.40

l/min

- Yes

Nickel %

(PAGE 1 OF 2)

Copper %

100.0

Manganese

0.5

HEAVY METALS: QUALITY ASSURANCE

99.6

% 100.0

l/min 20.20

0.21

0.16

0.3

Antimony µg/m³ 0.5

Leak Test Results Units

Post-Sampling Leak Rate l/min

Cobalt

Leak Test Acceptable

Allowable Absorption Efficiency

Antimony

Allowable Leak Rate

µg/m³

µg/m³

0.5

99.8

%

0.6

Lead

0.5

Copper

Yes

APPENDIX 2

µg/m³

Water Droplets

µg/m³

Manganese

Vanadium µg/m³

µg/m³

Run 1

Detection Limit Acceptable -

Measurement Uncertainty (MU)

Run 1

5

Are Water Droplets Present - No

Yes

Allowable MU %

CAT-RT (Version BO)

Page 38 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 41 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

APPENDIX 2

18

% 98.6

Less than 50% Faded %

°C

Allowable Isokinetic Range

Yes

Pre-Sampling Leak Rate

Leak Test Acceptable

Ambient Temperature Recorded?

Allowable Blank mg/m³

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

0.0500

Nature of Deviation Run Number

Run 1Test Conditions Units

Allowable Leak Rate

Silica Gel (Concurrent Water Vapour) Units Run 1

30

Isokinetic Criterion Compliance

Isokinetic Variation

%

HEAVY METALS: QUALITY ASSURANCE

20.00

- Yes

°C 180

Impingers Exit Temperature Units Run 1

Filter Temperatures Units

Units Run 1

95 - 115

(PAGE 2 OF 2)

Blank 1

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Ratio highest to lowest velocities between 3 and 5 : 1.

Units

Yes

Isokineticity Acceptable - Yes

Expected Sampling Rate

0.18

Maximum Filter Temperature

Leak Test Results

Post-Sampling Leak Rate

l/min

Run 1

Maximum Allowable Temperature

-

Blank Acceptable -

0.20

l/min

Maximum Temperature Recorded °C

0.40

Yes

Exit Temperature Acceptable

l/min

l/min

- Yes

Units Blank 1

Validity of Blank vs ELV

CAT-RT (Version BO)

Page 39 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 42 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

28.7

1.00Lr mg/m³ 0.0172

% 1.00

L

0.0362

2.00

Measured Quantities

mg/m³

Units

0.0065

mg/m³ 0.0184

% 28.7

% 14.7

1.04

- N/A

mg/m³

% N/A

% v/v N/A

mg/m³ 0.0705

L 1.04

0.50

Symbol Units Run 1

mg/m³

≤2%

%

Symbol

Requirement of Standard

%

Measured Quantities Units

APPENDIX 2

Run 1

Run 1

mg/m³

%

Tm 294.4

1.0

Lr 7.00

uTm K

0.0260

0.0015 1.00

0.0015

mg/m³

mg/m³

Parameter Units Run 1

HEAVY METALS: MEASUREMENT UNCERTAINTY CALCULATIONS

Value Standard uncertainty

Measured Quantities Symbol

0.68

- N/A

N/A

Uncertainty in Result

Oxygen Correction Part of MU Budget

1.1309

mg/m³

uL %

≤1%

%

Uncertainty as a Percentage

≤1%

Run 1

0.0705

-

≤2%

% 7.00

Run 1

Uncertainty in Measurement Units Sensitivity Coefficient

≤1%

No Requirement

N/A

%

uLr

Run 1Units

Vm 1.3020

Overall MU For O₂ Measurement

Measured Quantities

0.5

Run 1

0.0

ρm 100.7 uρm kPa

2.0

uHm % v/v

0.22

uVm

% -

%

Vm

0.0172

Measured Quantities Units

Hm

CAT-RT (Version BO)

Page 40 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 43 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

< <

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

Uncertainty

Water Vapour % v/v 10.88

Uncertainty ±% v/v

±g/hr 0.0

Mean

Units

Filter Housing Material Borosilicate Glass

0.0001

10.88

Impinger Material

Medite Europe Ltd, Clonmel

Parameter Units

Probe Material Titanium

1.15

Name of Analytical Laboratory RPS

Analytical Laboratory's Procedure M112

0.0

APPENDIX 2

MERCURY: RESULTS SUMMARY

0.0002

Uncertainty ±mg/m³ 0.0001

Parameter

Blank 1

Parameter Units Run 1

0.0001

Parameter

ISO 17025 Accredited Analysis?

Absorption Solution Nitric Peroxide & Potassium Dichromate

1 / 1

Mass Emission

1.15

Technical Procedure CAT-TP-06

Number of Sampling Lines Used 1 / 1

0.0

Mean

Standard

Concentration mg/m³ 0.0001

A3

EP 35 - Face Dryer Stage 1

MID 14385

Value

Borosilicate Glass

0.0

Out Stack

Run 1

Number of Sampling Points Used

Maximum

g/hr

Concentration mg/m³ 0.0002

Positioning of Filter

Filter Size and Material 47mm Quartz Fibre

Date of Sample Analysis 09/08/2016

Sample Point I.D.'s

Yes

CAT-RT (Version BO)

Page 41 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 44 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Velocity of stack gas, Vs

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

% wet oxygen measured in gas stream, ACT%O₂w % v/v

Ps = (Pb + (Pstatic / 13.6)

110.8

755.5

°C

Area of stack, As 3.80

4.16

10.88

1.3020

Barometric pressure, Pb

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

57.0

% v/v

%

Velocity pressure coefficient, Cp

m³/min

mmHg

0.3592

N₂

% v/v

Average pressure drop across orifice, ∆H

Volume of gas sample through gas meter, Vm m³

mmHg 761.3

% v/v

Total mass of liquid collected, Vlc g

Vwstd = (0.001246)(Vlc) m³ 0.1381

APPENDIX 2

% v/v N/A

20.86

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273) m³

Bwo = Vwstd / (Vmstd + Vwstd)

79.14

1.2690

g/gmol

Run 1

mm 6.01

N/A

Nozzle diameter, Dn

28.34Nozzle area, An mm²

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw) m³/min

Average of velocity heads, ∆Pavg

m³/min

Total sampling time, q min 60

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd)

Average stack gas temperature, Ts

m³/min N/A

-

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273)

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

% oxygen reference condition, REF%O₂

0.1088

mmH₂O

% v/v

mmH₂O

10.88

N/A

0.84

Units

34.97

-

N/A

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

Average dry gas meter temperature, Tm °C 21.4

Vmstw = (Vmstd)(100/(100 - Rwv)) m³

% dry oxygen measured in gas stream, ACT%O₂d

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

% v/v

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂)

Vmstw@X%oxygen = (Vmstw) / (O₂REFw)

- No

- N/A

N/A

Conversion factor (K/mm.Hg), Cf

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100)

2877.9

m³/min 3499.6

17.28

20.80

√mmH₂O

Qa = (60)(As)(Vs)

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps)) m/s

98.6

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

2564.8

Average square root of velocity heads, √∆P

Gas meter correction factor, Yd - 0.9310

N/A

15.34

27.66

% v/v

N/A

0.06

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w) -

47.0

Total mass collected in impingers (liquid trap) g 105.8

Total mass collected in impingers (silica trap) g 5.0

Pitot tube velocity constant, Kp -

g/gmol 28.84

1.1309

% v/v

Total

Stack static pressure, Pstatic mmH₂O -78.2

MERCURY: ISOKINETIC SAMPLING CALCULATIONS

Test

CAT-RT (Version BO)

Page 42 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 45 of 83

Sample Runs

<

-

Mass in Final Impinger -

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

<

<

Mass in Final Impinger <

<

<

<

0.0002

0.03

ISO

µg 0.04

mg/m³

MERCURY: SAMPLING DETAILS

Parameter Units

mg/m³ 0.0001

1.2690

-

Units Blank 1

Mass in Front Impinger/s

Total Mass Collected

Sampling Device

Volume Sampled (REF)

µg

µg

Reported Concentration

Mass in Front Impinger/s

µg

Calculated Concentration

10:35 - 11:35

Blank Dates -

Reported Concentration

0.02

Total Mass Collected

Mass on Filter / in Rinse

0.13

27/07/2016

Average Volume Sampled (REF)

27/07/2016

Calculated Concentration

Sampling Dates

µg 0.03

mg/m³ 0.0002

Run 1

0.29

1.2690

Parameter

APPENDIX 2

µg

Sampling Times -

µg

-

0.22

Mass on Filter / in Rinse

µg 0.18

mg/m³ 0.0001

CAT-RT (Version BO)

Page 43 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 46 of 83

Sample Runs

Maximum Filter Temperature

Ambient Temperature Recorded?

µg/m³ 2.0

Yes

Run 1

Allowable Absorption Efficiency

Units

Units Run 1

MU (Concurrent Water Vapour)

Units

Yes

% 98.6

Run 1

Absorption Efficiency

180

Maximum Allowable Temperature

Maximum Temperature Recorded

°C 30

Allowable Isokinetic Range

Allowable MU

- Yes

Where the emissions are < 30% of the ELV, MID 14385 does not require the 95% absorption efficiency requirement to be applied

Run 1

Filter Temperatures

MERCURY: QUALITY ASSURANCE

Leak Test Acceptable

-

Silica Gel (Concurrent Water Vapour)

Isokinetic Variation

Less than 50% Faded

%

Impingers Exit Temperature

10.6

Units Run 1

Absorption Efficiency Acceptable

Concentration Acceptable

Are Water Droplets Present

°C 18

Units Run 1

% 95 - 115

Measurement Uncertainty (MU)

-

0.03

UnitsWater Droplets

Units Run 1

Run 1

- Yes

Run 1

Run 1

-

Units

Concentration in Final Impinger

Pre-Sampling Leak Rate l/min 0.16

No

0.40

86.1

Leak Test Results

Units

%

Allowable Concentration

Isokineticity Acceptable

µg/m³Concentration in Final Impinger

Exit Temperature Acceptable - Yes

MU Acceptable % Yes

20.20

Absorption Efficiency

%

°C

APPENDIX 2

Mean Sampling Rate l/min

l/min

%

-

Units

(PAGE 1 OF 2)

Post-Sampling Leak Rate

Allowable Leak Rate

% 20

Yes

l/min 0.21

N/A

Test Conditions

N/A

Isokinetic Criterion Compliance

CAT-RT (Version BO)

Page 44 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 47 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

20.00

Allowable Leak Rate l/min

Validity of Blank vs ELV

-

l/min

0.0050

Leak Test Acceptable

0.40

Yes

Blank Acceptable

APPENDIX 2

MERCURY: QUALITY ASSURANCE(PAGE 2 OF 2)

l/min

Blank 1

Allowable Blank mg/m³

0.20

Nature of Deviation

Post-Sampling Leak Rate l/min

Run Number

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

Ratio highest to lowest velocities between 3 and 5 : 1.

Leak Test Results Units

Units

0.18

Yes-

Blank 1

Pre-Sampling Leak Rate

Expected Sampling Rate

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

CAT-RT (Version BO)

Page 45 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 48 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Run 1

uρm kPa 0.5

25.2

%

Uncertainty in Result

25.2

Run 1

1.00L

mg/m³

Measured Quantities Units

% N/A

N/A-

Oxygen Correction Part of MU Budget

uL %

Hm

Measured Quantities Symbol Symbol

Standard uncertainty

1.3020

Tm

%

%

0.00002mg/m³

No Requirement

Measured Quantities Units Run 1

%

mg/m³ 0.00001

Vm

Units Run 1

mg/m³ 0.0001

Overall MU For O₂ Measurement % N/A

mg/m³

N/A

0.0260uVm m³

0.00

0.00001

0.000001

294.4 uTm K

0.000001

12.9

Measured Quantities

% v/v

0.00001

mg/m³

mg/m³

Run 1

- N/A

1.00

1.04

uHm

0.0001

%

1.1309

≤2%

≤1%

% 0.50

1.00

Run 1

Lr

≤1%

%

mg/m³

%

mg/m³

Measured Quantities Units

Units

uLr

0.0

Lr 6.00

0.00003

1.04

6.00

≤2%

Uncertainty in Measurement Units Sensitivity Coefficient

Symbol

2.00

ρm

Uncertainty as a Percentage

APPENDIX 2

mg/m³

% v/v N/A

-

1.0

0.68

Parameter

100.7

Units Run 1

Run 1

L

2.0

Value

%

≤1%

Requirement of Standard

MERCURY: MEASUREMENT UNCERTAINTY CALCULATIONS

% -

Vm

CAT-RT (Version BO)

Page 46 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 49 of 83

Sample Runs (UPPER NATO I-TEQ)

- -

- -

- -

- -

- -

Sample Runs (UPPER WHO TEQ Humans / Mammals)

- -

- -

- -

- -

- -

Sample Runs (UPPER WHO TEQ Fish)

- -

- -

- -

- -

- -

Sample Runs (UPPER WHO TEQ Birds)

- -

- -

- -

- -

- -

Uncertainty

Uncertainty

ng/m³

Parameter

0.0016

µg/hr 0.3

APPENDIX 2

ng/m³ 0.0018 0.0018

Parameter Units

Mass Emission

0.0020

0.0007

DIOXINS & FURANS: RESULTS SUMMARY

Medite Europe Ltd, Clonmel

0.0016

(PAGE 1 OF 4)

Uncertainty ±ng/m³ 0.0007

EP 35 - Face Dryer Stage 1

Parameter Units

Concentration ng/m³

0.0008

Mass Emission

±ng/m³

Parameter Units

0.1

Concentration ng/m³ 0.0017

0.3

Uncertainty ±µg/hr 0.1

0.0017

Uncertainty

Run 1 Mean

NOTE: Where the maximum Blank concentration is higher than the Sample concentration, the Blank concentration has been reported.

µg/hr 0.3

Run 1

Mean

0.0020

0.3

Uncertainty ±µg/hr 0.1 0.1

Run 1

Uncertainty ±µg/hr

Concentration

Units Run 1

0.7

0.1

0.0007

Mass Emission µg/hr 0.3 0.3

TEQ1 - UPPER LIMITS (worst case where <LOD = LOD)

Uncertainty ±µg/hr 0.1

Concentration

Mass Emission µg/hr 0.7

0.0041 0.0041

±ng/m³

Mean

±ng/m³ 0.0007

Mean

0.30.3

0.0008

CAT-RT (Version BO)

Page 47 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 50 of 83

Sample Runs (LOWER NATO I-TEQ)

- -

- -

- -

- -

- -

Sample Runs (LOWER WHO TEQ Humans / Mammals)

- -

- -

- -

- -

- -

Sample Runs (LOWER WHO TEQ Fish)

- -

- -

- -

- -

- -

Sample Runs (LOWER WHO TEQ Birds)

- -

- -

- -

- -

- -

Run 1

Uncertainty

Uncertainty

Parameter

Mean

Parameter

Concentration ng/m³

±µg/hr 0.1

µg/hr 0.7

Run 1

0.1 0.1

0.0018

Run 1

0.1

±ng/m³

0.0017

Uncertainty

0.0008

0.0020

Uncertainty

Mean

0.0007

APPENDIX 2

Mass Emission µg/hr 0.3

Uncertainty ±µg/hr

NOTE: Where the maximum Blank concentration is higher than the Sample concentration, the Blank concentration has been reported.

0.3

NOTE: Where the maximum Blank concentration is higher than the Sample concentration, the Blank concentration has been reported.

Concentration ng/m³

0.1

µg/hr

±µg/hr 0.1

0.3

Units

Concentration ng/m³ 0.00410.0041

Concentration ng/m³ 0.0018

Uncertainty ±ng/m³

Mass Emission

DIOXINS & FURANS: RESULTS SUMMARY

0.0016

Uncertainty

Mean

Mass Emission

Parameter Units

±ng/m³ 0.0007

(PAGE 2 OF 4)

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

TEQ2 - LOWER LIMITS (best case where <LOD = 0)

0.0008

0.0020

±ng/m³

0.7

Uncertainty ±µg/hr 0.3

0.0016

Units

Mass Emission

Run 1

0.0007

NOTE: Where the maximum Blank concentration is higher than the Sample concentration, the Blank concentration has been reported.

Parameter Units

0.3

0.0017

Mean

0.3

0.3

0.0007

NOTE: Where the maximum Blank concentration is higher than the Sample concentration, the Blank concentration has been reported.

µg/hr 0.3

CAT-RT (Version BO)

Page 48 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 51 of 83

Blank Runs (UPPER NATO I-TEQ)

- -

- -

Blank Runs (UPPER WHO TEQ Humans / Mammals)

- -

- -

Blank Runs (UPPER WHO TEQ Fish)

- -

- -

Blank Runs (UPPER WHO TEQ Birds)

- -

- -

Blank Runs (LOWER NATO I-TEQ)

- -

- -

Blank Runs (LOWER WHO TEQ Humans / Mammals)

- -

- -

Blank Runs (LOWER WHO TEQ Fish)

- -

- -

Blank Runs (LOWER WHO TEQ Birds)

- -

- -

0.0041

DIOXINS & FURANS: RESULTS SUMMARY(PAGE 3 OF 4)

Units

0.0017

ng/m³

0.0018

Maximum

Medite Europe Ltd, Clonmel

ng/m³

0.0041

Parameter

TEQ2 - LOWER LIMITS (best case where <LOD = 0)

Parameter Blank 1

Concentration ng/m³ 0.0018

Concentration

ng/m³ 0.0041

Units

Units Blank 1

Blank 1 Maximum

Blank 1

Parameter

0.0017

ng/m³

Maximum

Concentration

0.0020

0.0018

Parameter Units

0.0041

Maximum

0.0017

Concentration

0.0020 0.0020

0.0020

Units Maximum

Concentration

Blank 1

Concentration

Concentration

Maximum

Parameter

Units Blank 1

ng/m³

ng/m³

0.0018

Concentration ng/m³ 0.0017

APPENDIX 2

Parameter Units Blank 1

Parameter Maximum

EP 35 - Face Dryer Stage 1

Maximum

TEQ1 - UPPER LIMITS (worst case where <LOD = LOD)

Parameter Units Blank 1

CAT-RT (Version BO)

Page 49 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 52 of 83

- -

- -

- -

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

Number of Sampling Lines Used 1 / 2

Date of Sample Analysis

1.06

EN 1948

1.06

Filter Housing Material Borosilicate Glass

Water Vapour % v/v

(PAGE 4 OF 4)

Medite Europe Ltd, Clonmel

APPENDIX 2

Technical Procedure CAT-TP-07

Name of Analytical Laboratory SAL

B3

90mm Quartz Fibre

Parameter Value

Borosilicate Glass

Uncertainty ±% v/v

Analytical Laboratory's Procedure

EP 35 - Face Dryer Stage 1

16/08/2016

DIOXINS & FURANS: RESULTS SUMMARY

Mean

9.51

XAD-2

Yes

Number of Sampling Points Used

SOP 1C

9.51

Parameter Units Run 1

Probe Material Titanium

Glassware Material

Out Stack

Filter Size and Material

ISO 17025 Accredited Analysis?

Absorption Material

Standard

Positioning of Filter

Sample Point I.D.'s

1 / 12

CAT-RT (Version BO)

Page 50 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 53 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

Average square root of velocity heads, √∆P

18.32

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂) g/gmol

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd) m³/min

Velocity of stack gas, Vs

Conversion factor (K/mm.Hg), Cf

N/A

48.0

N/A

Stack static pressure, Pstatic

APPENDIX 2

DIOXINS & FURANS: ISOKINETIC SAMPLING CALCULATIONS

Ps = (Pb + (Pstatic / 13.6)

-78.2

Total mass collected in impingers (silica trap)

g

0.3592

Total mass of liquid collected, Vlc

min

N/A

0.84

Vmstw = (Vmstd)(100/(100 - Rwv))

% v/v 9.51

m³/min

15.76

28.34

591.7

7.7542

Total sampling time, q

Vmstw@X%oxygen = (Vmstw) / (O₂REFw) m³

% v/v 0.06

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100) g/gmol

√mmH₂O

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw) m³/min

g

Average pressure drop across orifice, ∆H

N₂ % v/v

N/A

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

28.84

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

Test

35.9g

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

Barometric pressure, Pb mmHg 761.3

Average dry gas meter temperature, Tm

Volume of gas sample through gas meter, Vm

mmHg

Bwo = Vwstd / (Vmstd + Vwstd)

Qa = (60)(As)(Vs)

Velocity pressure coefficient, Cp -

2674.4

% oxygen reference condition, REF%O₂ % v/v N/A

% dry oxygen measured in gas stream, ACT%O₂d % v/v

°C

% v/v

Total % v/v 20.86

No

% wet oxygen measured in gas stream, ACT%O₂w

Vwstd = (0.001246)(Vlc) m³ 0.7373

m³ 0.0951

Units Run 1

7.0169

Gas meter correction factor, Yd - 0.9310

555.8

27.81

mmH₂O

Total mass collected in impingers (liquid trap)

m³ 8.1511

% v/v

-

mmH₂O

N/A

755.5

-

24.1

N/A

mmH₂OAverage of velocity heads, ∆Pavg

- 34.97

4.28

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps)) m/s

20.80

-

Nozzle area, An

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

m³ N/A

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100)) % 97.8

Area of stack, As m²

Pitot tube velocity constant, Kp

79.14

3593.9

3.80

-

N/A

% v/v

Average stack gas temperature, Ts °C 57.0

360

mm²

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273) m³

9.51

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) m³/min

Nozzle diameter, Dn mm 6.01

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273) m³/min 2955.4

CAT-RT (Version BO)

Page 51 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 54 of 83

Where: ISO stands for Manual Isokinetic Sampling Train

2378-TCDD

12378-PeCDD

123478-HxCDD

123678-HxCDD

123789-HxCDD

1234678-HPeCDD

OCDD

Total Dioxins

2378-TCDF

12378-PeCDF

23478-PeCDF

123478-HxCDF

123678-HxCDF

234678-HxCDF

123789-HxCDF

1234678-HPeCDF

1234789-HPeCDF

OCDF

Total Furans

Totals

Total Concentration

Limit of Detection

Where: ND stands for Non Detected

DL stands for Analytical Detection Limit

TEQ1 refers to Non Detected Congeners at the Detection Limit

TEQ2 refers to Non Detected Congeners at Zero

% Rec stands for the Recovery Percentage of the Sample

-

- 0.0014

-

-

0.0003

0.0017

0.0003

0.0001

0.0080

0.0080

0.0109

0.0014

0.0003

-

0.0042

0.0003

113

127

- -

0.000001

0.0003

0.0028

0.000001

0.0002

-0.0030

ng

ng

-

- 0.0012

0.0075

-

0.0003

-

0.0001

0.000002

0.0022

0.0050

0.0050

-

0.0001

0.0001

0.0096

0.0001

0.000001

0.0028

0.0075

0.0003

ng

780.0030

0.0022

0.0022

0.0030

0.0002

0.0000

0.0001

99

0.0030

0.0020

0.00300.0030

0.0020

0.0003

0.0003

0.0003

0.0030

0.0003

0.0003

0.0003

TEQ2 TEQ1

0.0003

0.0050

0.00002

0.00001

11:00 - 17:00Sampling Times

Sampling Dates

Sampling Device

0.000008

0.0004

0.0003

0.000002

0.0051

0.0019

0.0020

0.0030

0.0540

0.0030 0.0030

0.0030

0.000008

0.0020

0.0039 0.0047

0.0002

0.0002

0.0001

0.0003

0.0001

0.0015

0.0001

96

0.0047 0.0149

0.0080 0.000001

0.0022

0.0003

1230.0080

0.0015

0.0022

0.0050

0.000001

0.0003

0.0003

ng

0.0002

-

0.0011

0.0030

Units

-

0.0012

0.00420.0216

0.0020

0.0003

0.0055

0.0003

0.0050

0.0055

0.0003

0.0003

0.0002

ng/m³

0.0051 0.0039

0.0012

0.0093

0.0012

0.0093 0.0202

0.0026

0.0096

0.0012

RUN 1

0.000001

ng

ng

0.0030

0.0001

0.000002

0.0020

0.0003

0.0003

0.0001

0.0001

0.0020

0.00002

0.0001

0.0008

0.0003

0.0001

-

-

0.0061ng

0.000005

TEQ1

Parameter

0.00002

0.0003

0.0030

0.0011

0.0002

0.0003

0.00002

0.00001

TEQ2TEQ2

0.0008

26/07/2016

Volume Sampled (REF) m³

Value

ng

0.0001

0.0030

0.0055

7.7542

NATO

I-TEQ

WHO Humans /

Mammals

WHO

Fish

WHO

Birds

DL TEQ1 TEQ2Parameter Units Result

APPENDIX 2

ISO

TEQ1

-ng

0.0022

ng

0.0004

0.0055

0.0002

ng

0.00020.0002

0.0003

ng

0.0005

0.0008

0.0001

0.0000

0.0001

0.000005

0.0003

0.0028

0.0003

0.0003

-

100

121

106

109

0.0149

0.0003

DIOXINS & FURANS: SAMPLING DETAILS

0.0020

0.0075

0.0050ng

78

75

0.0030

0.0021

0.0002

0.0001

0.0002

0.0054 0.0054

0.000001

0.0002

0.00001

0.0028

0.0109

0.0014

ng

ng

0.0003

0.0002

0.00001ng

ng

0.0061

0.0080

0.0003

0.0002

0.000002

-

0.0020

% Rec

0.0001

0.0003

0.0057 0.0057

0.0008

0.0001

0.000001

0.0020

0.0002

0.0017

0.0001

116

0.0011

ng

ng

- -

ng 0.0756 0.0202

0.0026

ng/m³ -

0.00010.0080

0.0005

CAT-RT (Version BO)

Page 52 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 55 of 83

Where: ISO stands for Manual Isokinetic Sampling Train

2378-TCDD

12378-PeCDD

123478-HxCDD

123678-HxCDD

123789-HxCDD

1234678-HPeCDD

OCDD

Total Dioxins

2378-TCDF

12378-PeCDF

23478-PeCDF

123478-HxCDF

123678-HxCDF

234678-HxCDF

123789-HxCDF

1234678-HPeCDF

1234789-HPeCDF

OCDF

Total Furans

Totals

Total Concentration

Where: ND stands for Non Detected

DL stands for Analytical Detection Limit

TEQ1 refers to Non Detected Congeners at the Detection Limit

TEQ2 refers to Non Detected Congeners at Zero

% Rec stands for the Recovery Percentage of the Sample

BLANK 1

0.00002

0.0006

0.0006 0.0006

0.0058

0.0005 0.0005 0.0005

TEQ2 TEQ1TEQ2

Sampling Device -

0.0135 0.0135

-

-

0.0050

0.00200.0020

ng 0.0050 0.00050.0005

0.0035

-

0.0001

0.0018 0.0018

Parameter Units Result

0.000008

0.0080

ng

0.00002

0.00001

0.0020

0.0001 0.0001 0.0001

0.000001

0.0001

0.0060

0.0005

TEQ1

Parameter

0.0062 0.0065

0.0002

0.0073

0.0141 0.0141

0.0008 0.0008 0.0008

ISO

WHO

Fish

% RecDL

0.00330.0020

0.0006

0.0020

0.00002

0.0035

0.00001

ng

Units

0.0001

0.000002 0.0000020.0080 0.0080

0.0044 0.0044

WHO

Birds

- 0.0041

ng

0.0002

0.0002

ng

0.0020

0.0002

0.000002 0.0000020.00001

TEQ2 TEQ1

0.0050

99

0.0008

0.000001 0.000001

0.0012

0.0026

ng 0.0727 - 0.0097 0.0097 0.0073

0.0001

0.0020

0.0006 96

106

0.0080 0.0001

ng 0.0075

0.0050 0.0001

0.0006ng 0.0058 0.0021

-

0.0006 0.00060.00120.0012

-

0.000001 0.000001 0.000001

0.0002

0.0006

103

0.0120

0.0017

0.0156 0.0322- 0.0322

ng/m³

0.1002

-

0.0006

Value

0.0018 0.0018 0.0041

0.0012

ng

99

0.0004

0.0110

TEQ1 TEQ2

0.0055

0.00200.0020

ng

0.00002

0.0020

0.0020

0.00001

0.0002

121

0.0020 0.0020 0.0020ng 0.0020

0.0002

0.0055

0.0020

0.0008

0.0020 0.0020

0.0035

0.0002

ng

0.0002

0.0275

0.0002

7.7542

Sampling Dates - 26/07/2016

Average Volume Sampled (REF)

APPENDIX 2

DIOXINS & FURANS: SAMPLING DETAILS

ng 0.0035

0.0058

0.0055

0.0050

0.0004 0.0002

0.0006 0.0006 0.0006

ng 0.00020.0002

0.0020 0.0020

76

0.0020

0.0006 0.0006

0.0120 0.0120

0.0050

0.0077

0.0001 0.0001

0.0005

0.0062

0.000020.0002 0.00002

0.0055

WHO Humans /

Mammals

ng

NATO

I-TEQ

0.0033

0.0001

-

0.0050

0.0002

106

0.0010

0.0035

0.000008

(Continued)

1060.0002

0.0020

0.0035 0.0035

0.0065

0.0035

0.0001

0.0010

0.0001

0.0001

-0.0004 0.0008

0.0006 0.0006

0.0156

0.0004

1220.0001

102

0.000001

-

-

0.0001

0.0008

0.0001 0.0001 0.0001 0.00001

ng

ng 0.0008 0.0008 0.0008

0.0001

ng

0.0001ng

0.0110 0.0110

0.0005

0.0091 0.0091 0.0263 0.0263

0.00001

0.0017

1010.0077

0.0006

128

ng

0.000001

CAT-RT (Version BO)

Page 53 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 56 of 83

Sample Runs

Leak Test Acceptable

%

Are Water Droplets Present

-

No

l/min

Isokinetic Criterion Compliance

Ambient Temperature Recorded?

Exit Temperature Acceptable

Maximum Allowable Temperature

Less than 50% Faded

-

Condenser Exit Temperature Units Run 1

19

%

Units

Pre-Sampling Leak Rate

APPENDIX 2

DIOXINS & FURANS: QUALITY ASSURANCE

MU Acceptable %

0.24

Units

Run 1

%

Allowable Isokinetic Range 95 - 115

Isokinetic Variation

Run 1

Maximum Filter Temperature

(PAGE 1 OF 2)

Yes

11.2

20

l/min 0.40Post-Sampling Leak Rate

°C 120

Silica Gel (Concurrent Water Vapour) Units

Run 1

MU (Concurrent Water Vapour) Units Run 1

Yes

Units Run 1

97.8

% Yes

Allowable MU

l/min

21.08

Run 1

%

Units

Water Droplets

Measurement Uncertainty (MU)

Units

Mean Sampling Rate

-

-

°C 20

Run 1

Maximum Temperature Recorded °C

Leak Test Results

Allowable Leak Rate l/min 1.05

Yes

Isokineticity Acceptable - Yes

Filter Temperatures

Test Conditions

Yes

CAT-RT (Version BO)

Page 54 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 57 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

-

APPENDIX 2

(PAGE 2 OF 2)

Units Blank 1

Expected Sampling Rate l/min 20.00

0.0100

Allowable Leak Rate

Blank 1

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Ratio highest to lowest velocities between 3 and 5 : 1.

l/min

Blank Acceptable

Validity of NATO I-TEQ Blank vs ELV

Allowable Blank ng/m³

DIOXINS & FURANS: QUALITY ASSURANCE

Leak Test Results Units

Run Number

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

l/min 1.00

Nature of Deviation

0.23Sampling Leak Rate

Yes

Leak Test Acceptable Yes

-

CAT-RT (Version BO)

Page 55 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 58 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Symbol UnitsRun 1

Tm

%

Run 1

0.0 % v/v 1.0

0.0000L

ng/m³ 0.0002

L

%

kPa 0.5

uVm 0.163

0.67

Requirement of Standard

%

uL

ng/m³

Hm

2.0297.1

39.8%

ng/m³

%

Units

Measured Quantities

ng/m³

1.90

Measured Quantities Units Run 1

1.00

8.1511

≤1%

-

APPENDIX 2

DIOXINS & FURANS (NATO I-TEQ): MEASUREMENT UNCERTAINTY CALCULATIONS

Value

UnitsParameter

≤1%

Vm

%

%

uHm

Run 1

1.00

uTm

N/A

K

%

20.4

≤1%

1.00

Symbol

%

- N/A

0.0007

ng/m³

-

Measured Quantities

ρm

N/A

- N/A

% v/v N/A

ng/m³

ng/m³ 0.0002

N/A

%

Lr

%

Units Run 1

0.0004

Uncertainty in Result

Measured Quantities

Uncertainty in Measurement Units

39.8

m³ 7.0169

Units Run 1

Sensitivity Coefficient

Measured Quantities

10.00 No Requirement

0.0007

ng/m³

ng/m³ 0.0000

Vm

Uncertainty as a Percentage

0.00

1.90

Lr 10.00

ng/m³ 0.0000

Run 1

Symbol

100.7

uρm

%

Standard uncertainty

≤2%

≤5%

Oxygen Correction Part of MU Budget

uLr

Run 1

0.50

%

0.0002

2.00

Overall MU For O₂ Measurement

CAT-RT (Version BO)

Page 56 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 59 of 83

Sample Runs

- -

- -

- -

- -

- -

- -

- -

- -

Blank Runs

- -

< <

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

11.10

APPENDIX 2

FORMALDEHYDE: RESULTS SUMMARY

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

Parameter Units Run 1

Filter Housing Material Borosilicate Glass

Mean

Parameter

CAT-TP-19

Maximum

Concentration

Blank 1

mg/m³ 0.02

Standard

Out Stack

Filter Size and Material 47mm Quartz Fibre

Number of Sampling Lines Used

Units Run 1

Uncertainty ±% v/v 1.21 1.21

Uncertainty

1281.1

Parameter

±mg/m³

Probe Material Titanium

0.02

Parameter Value

Water Vapour

B3

11.10

Units

Sample Point I.D.'s

US EPA M316

Technical Procedure

Mean

CAT-AP-05

1 / 1

Number of Sampling Points Used 1 / 1

7.81

Mass Emission g/hr 4134.9

±g/hr

Impinger Material Polyethylene

Absorption Solution HPLC Grade Water

Positioning of Filter

1281.1

Date of Sample Analysis 04/08/2016

% v/v

mg/m³ 25.52

7.81

25.52

4134.9

Uncertainty

Concentration

ISO 17025 Accredited Analysis? Yes

Name of Analytical Laboratory CAT

Analytical Laboratory's Procedure

CAT-RT (Version BO)

Page 57 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 60 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

% v/v

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd)

Nozzle area, An

m³/min

mmHg 755.5

Barometric pressure, Pb mmHg

% wet oxygen measured in gas stream, ACT%O₂w

Gas meter correction factor, Yd -

761.3

Ps = (Pb + (Pstatic / 13.6)

g

m³ 0.6643

27.64

Average stack gas temperature, Ts

Area of stack, As m²

m³/min

Vmstd@X%oxygen = (Vmstd) / (O₂REFd)

Total mass of liquid collected, Vlc

Total mass collected in impingers (liquid trap)

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

3560.6

59.2

m³ N/A

Stack static pressure, Pstatic

Units Run 1

20.86

- 34.97

N/A

FORMALDEHYDE: ISOKINETIC SAMPLING CALCULATIONS

Test

°C 26.3

% 101.4

APPENDIX 2

g/gmol 28.84

Average of velocity heads, ∆Pavg

m³/min N/A

Volume of gas sample through gas meter, Vm

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂)

N₂ % v/v 79.14

N/A

28.34

N/A

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100)

g

15.61

Nozzle diameter, Dn mm

3.80

4.23

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) m³/min

Conversion factor (K/mm.Hg), Cf

Vmstw@X%oxygen = (Vmstw) / (O₂REFw)

Total % v/v

% v/v 20.80

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273)

Total mass collected in impingers (silica trap) g

0.9310

m³ 0.0738

-

% v/v

5.5

53.7

mmH₂O

% dry oxygen measured in gas stream, ACT%O₂d

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d)

% v/v

-

N/A

m³ 0.1110

- N/A

No

% v/v

% oxygen reference condition, REF%O₂ % v/v

m³ N/A

N/A

Vmstw = (Vmstd)(100/(100 - Rwv))

°C

Average square root of velocity heads, √∆P √mmH₂O

mm²

-

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100))

Velocity pressure coefficient, Cp

mmH₂O 17.87

Qa = (60)(As)(Vs)

6.01

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w)

2603.0

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw) m³/min

m³ 0.5906

11.10

m/s

m³ 0.6912

% v/v 11.10

Total sampling time, q

Velocity of stack gas, Vs

Pitot tube velocity constant, Kp

Bwo = Vwstd / (Vmstd + Vwstd)

min 30

2928.1

-78.2

0.06

48.1

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction)

0.84

Average dry gas meter temperature, Tm

57.0

Average pressure drop across orifice, ∆H mmH₂O

g/gmol

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps))

Vwstd = (0.001246)(Vlc)

- 0.3592

CAT-RT (Version BO)

Page 58 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 61 of 83

Sample Runs

-

-

-

-

-

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

<

-

<

<

63.24

Parameter Units

APPENDIX 2

mg/m³ 25.52

FORMALDEHYDE: SAMPLING DETAILS

Mass in Back Impinger

-

Laboratory Result for Impingers

Calculated Concentration

Volume in Impingers

Calculated Concentration

µg 16956.5

16221.1

Sampling Dates

Parameter Units Blank 1

735.5

Sampling Device -

ml 304.1

µg/ml 0.05

Volume in Front Impingers

m³ 0.6643

6.76

µg

ml

µg/ml

ISO

µg

108.8

Run 1

Blank Dates

0.02

26/07/2016

Volume in Back Impinger

Volume Sampled (REF)

Total Mass Collected

-

- 08:40 - 09:10

256.5

Mass in Front Impingers

ml

15.2Total Mass Collected µg

Sampling Times

Laboratory Result for Back Impinger

Laboratory Result for Front Impingers µg/ml

27/07/2016

Average Volume Sampled (REF) m³ 0.6643

mg/m³

CAT-RT (Version BO)

Page 59 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 62 of 83

Sample Runs

0 0 0 0

Run 1

%

0.43

Run 1

0.31

%

Units Run 1

Water Droplets

%

Units

Isokinetic Criterion Compliance

10.9

Units

Absorption Efficiency Acceptable -

Measurement Uncertainty (MU) %

Less than 50% Faded

21.45l/min

Run 1

APPENDIX 2

120

0.24

Units

Allowable Absorption Efficiency

Post-Sampling Leak Rate

N/A

l/min

Mean Sampling Rate

Units

Maximum Filter Temperature °C

101.4

Isokineticity Acceptable -

Run 1

Yes

MU (Concurrent Water Vapour)

Units

Units

Allowable Isokinetic Range

Pre-Sampling Leak Rate l/min

N/A

-

Units Run 1

Yes

20

-

NoAre Water Droplets Present

Run 1

Filter Temperatures

%

Leak Test Results

- Yes

Test Conditions

Allowable MU

Isokinetic Variation

Yes

Yes

Ambient Temperature Recorded?

95.7

(PAGE 1 OF 2)

FORMALDEHYDE: QUALITY ASSURANCE

Absorption Efficiency

Leak Test Acceptable

Silica Gel (Concurrent Water Vapour)

%

%

Absorption Efficiency

%

MU Acceptable

95 - 115

Run 1

Allowable Leak Rate l/min

CAT-RT (Version BO)

Page 60 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 63 of 83

Blank Runs

Method Deviations

1

wx

wx

- - - - -

- - - - -

- - - - -

- - - - -

Blank 1

Expected Sampling Rate

APPENDIX 2

FORMALDEHYDE: QUALITY ASSURANCE

Blank Acceptable

Post-Sampling Leak Rate l/min

l/min 0.40

Run Number

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

Leak Test Results

Blank 1

Allowable Leak Rate

- Yes

20.00l/min

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Ratio highest to lowest velocities between 3 and 5 : 1.

2.0

Nature of Deviation

0.10

(PAGE 2 OF 2)

Pre-Sampling Leak Rate

Leak Test Acceptable - Yes

Units

Allowable Blank mg/m³

Validity of Blank vs ELV Units

l/min 0.10

CAT-RT (Version BO)

Page 61 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 64 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

% v/v

uρm

Tm

N/A

mg/m³

mg/m³

Vm

% 15.7

1.00

7.50

0.67 ≤1%

1.45

Requirement of Standard

Units Run 1

%

Sensitivity Coefficient

2.00

0.5

L

% v/v

4.01

Measured Quantities

mg/m³

0.50

Units

Uncertainty in Measurement Units

Symbol

Run 1

Measured Quantities

Measured Quantities

mg/m³

2.04

1.00

7.81

Units

Parameter Units

%

mg/m³ N/A

0.684

Oxygen Correction Part of MU Budget

Run 1

mg/m³

N/A

1.914

30.6

mg/m³

%

1.00

Units Run 1

UnitsMeasured Quantities

Lr

≤1%

% -

N/A

0.5906

mg/m³

43.22

0.6912

0.0

%

mg/m³ 7.81

FORMALDEHYDE: MEASUREMENT UNCERTAINTY CALCULATIONS

kPa

Standard uncertainty

1.0uHmHm

%

0.0138uVm

Run 1

0.2130

Overall MU For O₂ Measurement

≤2%

% 30.6

1.9143

Run 1

APPENDIX 2

uLr

% -

Uncertainty as a Percentage

Measured Quantities

≤2%

Value

uL

≤1%%

%

7.50

Run 1

K

Vm

ρm

2.0299.3

100.7

uTm

L 1.45

SymbolSymbol

%

mg/m³

Run 1

0.213

Lr

Uncertainty in Result

No Requirement

-

%

N/A

- N/A

CAT-RT (Version BO)

Page 62 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 65 of 83

Sample Runs

- -

< <

- -

< <

- -

- -

- -

- -

Blank Runs

- -

< <

General Sampling Information

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

Concentration

Concentration

Parameter Units Blank 1

0.001

1.1

0.007

g/hr 1.1

Uncertainty ±mg/m³

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

APPENDIX 2

ISOCYANATES: RESULTS SUMMARY

0.007

Parameter Value

mg/m³

Uncertainty ±g/hr 0.2 0.2

Parameter Units Run 1

Units Run 1

0.007

Maximum

Filter Housing / Nozzle Material Borosilicate Glass

mg/m³ 0.007

Out Stack

Filter Size and Material 1 2-PP Impregnated 47mm Glass Fibre

Number of Sampling Lines Used

B3

Yes

Probe Material Titanium

Mean

0.001

Date of Sample Analysis 12/08/2016

MeanParameter

Mass Emission

Name of Analytical Laboratory SAL

Analytical Laboratory's Procedure M119

ISO 17025 Accredited Analysis?

Positioning of Filter

Number of Sampling Points Used

Water Vapour % v/v 12.23

Uncertainty ±% v/v 1.00

Standard US EPA CTM36

1 / 1

1 / 1

Technical Procedure

Sample Point I.D.'s

CAT-TP-17

1.00

12.23

CAT-RT (Version BO)

Page 63 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 66 of 83

Absolute pressure of stack gas, Ps

Volume of water vapour collected, Vwstd

Volume of gas metered dry, Vmstd

Moisture content, Bwo & Rwv

Bwo as a percentage

Reported Water Vapour, checked with Tables in EN 14790, Rwv

Volume of gas metered wet, Vmstw

Volume of gas metered at Oxygen Reference Conditions, Vmstd@X%O₂ & Vmstw@X%O₂

Molecular weight of dry gas stream, Md

CO₂ (Estimated)

O₂

Molecular weight of stack gas (wet), Ms

Total flow of stack gas: Actual (Qa), Wet (Qstw), Dry (Qstd), Wet@O₂REF (QstwO₂), Dry@O₂REF (QstdO₂)

Percent isokinetic, %I

mm 4.97

m³/min

Vs = ((Kp)(Cp)(√∆P)(√Ts + 273)) / (√(Ms)(Ps))

mm² 19.43

Total sampling time, q min 30

m/s 15.66

Average stack gas temperature, Ts °C 57.0

%I = (4.6398E⁶)(Ts+273)(Vmstd) / (Ps)(Vs)(An)(q)(1 - (Rwv/100)) %

Qstd = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) m³/min 2578.1

QstwO₂ = ((Qa)(Ps)(Cf)) / ((Ts) + 273) / (O₂REFw) m³/min N/A

QstdO₂ = ((Qa)(Ps)(Cf)(1 - (Rwv/100))) / ((Ts) + 273) / (O₂REFd) m³/min N/A

Qa = (60)(As)(Vs) m³/min

2937.3

3571.8

-

Qstw = ((Qa)(Ps)(Cf)) / ((Ts) + 273)

Nozzle diameter, Dn

Average square root of velocity heads, √∆P √mmH₂O 4.23

Nozzle area, An

101.8

Total mass collected in impingers (silica trap)

0.3592Conversion factor (K/mm.Hg), Cf

Area of stack, As m² 3.80

Vmstw@X%oxygen = (Vmstw) / (O₂REFw) m³ N/A

Vmstd@X%oxygen = (Vmstd) / (O₂REFd) m³ N/A

% v/v 0.06

% v/v 20.80

Total % v/v 20.86

% oxygen reference condition, REF%O₂ % v/v N/A

27.52

Velocity of stack gas, Vs

Pitot tube velocity constant, Kp - 34.97

Md = 0.44(%CO₂)+0.32(%O₂)+0.28(%N₂) g/gmol 28.84

Velocity pressure coefficient, Cp - 0.84

Ms = Md(1 - (Rwv/100)) + 18(Rwv/100) g/gmol

O₂ Reference Factor wet (O₂REFw) = (21 - REF%O₂) / (21 - ACT%O₂w) -

Total mass collected in impingers (liquid trap) g

APPENDIX 2

ISOCYANATES: ISOKINETIC SAMPLING CALCULATIONS

Test Units Run 1

Barometric pressure, Pb mmHg 761.3

Vmstw = (Vmstd)(100/(100 - Rwv)) m³ 0.4584

g 16.5

IED & Incinerates Hazardous Material? (Yes = no positive O₂ correction) - No

Ps = (Pb + (Pstatic / 13.6) mmHg 755.5

O₂ Reference Factor dry (O₂REFd) = (21 - REF%O₂) / (21 - ACT%O₂d) - N/A

mmH₂O

N₂ % v/v 79.14

12.23% v/v

Vwstd = (0.001246)(Vlc)

Gas meter correction factor, Yd -

% v/v 12.23

Average pressure drop across orifice, ∆H

0.0561

Volume of gas sample through gas meter, Vm

28.5

Average of velocity heads, ∆Pavg mmH₂O 17.90

N/A

0.9310

N/A

% dry oxygen measured in gas stream, ACT%O₂d % v/v N/A

m³ 0.4650

Average dry gas meter temperature, Tm °C 21.8

Bwo = Vwstd / (Vmstd + Vwstd) m³ 0.1223

Vmstd = ((0.3592)(Vm)(Pb + (∆H/13.6))(Yd)) / (Tm + 273) m³ 0.4024

Total mass of liquid collected, Vlc g 45.0

Stack static pressure, Pstatic mmH₂O -78.2

% wet oxygen measured in gas stream, ACT%O₂w % v/v

22.3

CAT-RT (Version BO)

Page 64 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 67 of 83

Sample Runs

<

<

-

-

-

Where: ISO stands for Manual Isokinetic Sampling Train

Blank Runs

<

<

<

<

<

- ISO

ISOCYANATES: SAMPLING DETAILS

Calculated Concentration

0.007

Sampling Times - 09:55 - 10:25

Sampling Dates - 27/07/2016

Sampling Device

APPENDIX 2

µg

Methyl Diisocyanate (MDI) µg

Hexamethylene Diisocyanate (HDI) µg 1.00

0.4584

Total Mass Collected µg 3.00

Calculated Concentration mg/m³

1.00

Volume Sampled (REF)

Methyl Diisocyanate (MDI)

Hexamethylene Diisocyanate (HDI)

Toluene Diisocyanates (TDI)

µg

µg 1.00

0.007

Parameter

Toluene Diisocyanates (TDI) µg 1.00

1.00

26/07/2016Blank Dates -

1.00

Total Mass Collected µg 3.00

mg/m³

Average Volume Sampled (REF) m³ 0.4584

Parameter Units Run 1

Units Blank 1

CAT-RT (Version BO)

Page 65 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 68 of 83

Sample Runs

Blank Runs

Method Deviations

1

wx

- - - - -

- - - - -

Yes

Allowable Leak Rate

Isokinetic Criterion Compliance Units Run 1

Leak Test Results

Ambient Temperature Recorded? - Yes

Isokinetic Variation % 101.8

Yes

Run 1

The sample points where the angle of swirl was > 15° were omitted from the sampling exercise.

Run Number

Expected Sampling Rate l/min

Units

20.00

Allowable Blank mg/m³ 0.0

Filter Temperatures

Blank 1

- Yes

Sampling Leak Rate l/min 0.20

Nature of Deviation

Blank 1

Blank Acceptable -

(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)

l/min

Allowable Isokinetic Range

0.40

°C

Are Water Droplets Present

105

Units Run 1

Isokineticity Acceptable - Yes

Maximum Filter Temperature

Leak Test Acceptable

% 95 - 115

Test Conditions Units

Validity of Blank vs ELV Units

MU (Concurrent Water Vapour)

Allowable Leak Rate

0.14

APPENDIX 2

ISOCYANATES: QUALITY ASSURANCE

Leak Test Results Units Run 1

l/min

Leak Test Acceptable - Yes

MU Acceptable % Yes

Silica Gel (Concurrent Water Vapour) Units Run 1

Pre-Sampling Leak Rate l/min

Measurement Uncertainty (MU) % 8.2

Units Run 1

0.15

Mean Sampling Rate l/min 14.43

0.29

%Less than 50% Faded

Water Droplets Units

Post-Sampling Leak Rate l/min

Run 1

- No

% 20Allowable MU

CAT-RT (Version BO)

Page 66 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 69 of 83

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (Actual)

Sampled Gas Temperature

Sampled Gas Pressure

Sampled Gas Humidity

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

Sampled Volume (STP)

Leak

Laboratory Result

O₂ Correction Factor

Stack Gas O₂ Content

MU for O₂ Correction

Combined uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

Expanded uncertainty (95% confidence), without Oxygen Correction

Expanded uncertainty (95% confidence), with Oxygen Correction

Expanded uncertainty (95% confidence), estimated with Method Deviations

Reported Uncertainty

ρm 100.7

1.00

%

1.00mg/m³

Requirement of Standard

% 2.00

Lr

Units

mg/m³ 0.00

mg/m³ 0.00

Symbol

% 0.68

0.00

12.9

%

Vm

uHm % v/v

0.4024

mg/m³ 0.0004

Lr

% 1.04

6.00

%

Measured Quantities

Vm

0.000

mg/m³ 0.0000

Parameter Units

Uncertainty as a Percentage

Measured Quantities

≤2%

Measured Quantities

mg/m³ N/A

≤1%

uL

Uncertainty in Measurement Units

Oxygen Correction Part of MU Budget

- N/A

mg/m³ 0.000

No Requirement

K

19.4

mg/m³ 0.00

%

mg/m³

19.4%

%

% N/A

Run 1

-

0.02

0.50

Measured Quantities Units Run 1

Units

uLr %

Sensitivity Coefficient

0.000L

Uncertainty in Result

mg/m³

Units

≤1%

6.00

Run 1

≤1%

-

N/A

N/A

% v/v

% -

0.5

≤2%

Hm

1.00

Run 1

1.0

L 1.04

Run 1

uρm

Run 1

kPa

2.0Tm 294.8

Symbol Units Run 1Run 1

uTm

uVm m³ 0.0093

0.0

APPENDIX 2

0.4650

ISOCYANATES: MEASUREMENT UNCERTAINTY CALCULATIONS

Symbol

Value Standard uncertainty

Measured Quantities

Overall MU For O₂ Measurement % N/A

CAT-RT (Version BO)

Page 67 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 70 of 83

Sample Runs

- -

- -

- -

- -

- -

General Sampling Information

NOTE: Dilution performed to achieve correct span value

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

APPENDIX 2

Parameter

1 / 1

127.8

OXIDES OF NITROGEN (as NO₂): RESULTS SUMMARY

Medite Europe Ltd, Clonmel

413.34

Yes

EP 35 - Face Dryer Stage 1

Parameter Units Mean

04/12/2019

0.79

Uncertainty ±mg/m³

0.79

Probe Material Titanium

317.1

Mass Emission

1.96

Sample Point I.D.'s

Heated Head Filter Used

Filtration Type / Size

CAT-TP-39

317.1±g/hr

Standard

Technical Procedure

Number of Sampling Lines Used 1 / 1

Number of Sampling Points Used

Span Gas Uncertainty (%)

Run 1

EN 14792

0.1µm Glass Fibre

Uncertainty

2

C1

Span Gas Reference Number CYL 4.0161

Span Gas Expiry Date

Concentration mg/m³

Span Gas Start Pressure (bar) 100

Gas Cylinder Concentration (ppm)

Span Gas Type Nitrogen Monoxide

180°C

Nitrogen (5 Grade)Zero Gas Type

1.96

g/hr 127.8

Value

Heated Line Temperature

Date & Result of Last Converter Check 20/08/2015 - 95.5%

CAT-RT (Version BO)

Page 68 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 71 of 83

Graphical Trend of Data

COVER ME WITH CHART/S

APPENDIX 2

OXIDES OF NITROGEN (as NO₂): DATA TREND

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

15

:31

15

:32

15

:33

15

:34

15

:35

15

:36

15

:37

15

:38

15

:39

15

:40

15

:41

15

:42

15

:43

15

:44

15

:45

15

:46

15

:47

15

:48

15

:49

15

:50

15

:51

15

:52

15

:53

15

:54

15

:55

15

:56

15

:57

15

:58

15

:59

16

:00

Co

nce

ntr

atio

n (

mg/

m³)

Oxides of Nitrogen (as NO₂) At Reference Conditions

- Run 1

CAT-RT (Version BO)

Page 69 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 72 of 83

Sampling Details

Quality Assurance

Zero Drift 0 0 0

Zero Drift 0 0 0

Zero Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Method Deviations

1

x

- - -

- - -

- - -

Span Gas Value ppm

Span Down Sampling Line (Pre) ppm 63.50

Run 1

ppm

ppm

(x = deviation applies to the associated run)

There are no deviations associated with the sampling employed.

18 - 19

CA

L 2

Span Down Sampling Line (Post)

Units

Span Down Sampling Line (Post) ppm 63.10

ppm -0.40

ppmSpan Down Sampling Line (Post)

ppm

Span Down Sampling Line (Pre) ppm

Yes

-

APPENDIX 2

ppm

Run Ambient Temperature Range

Zero Down Sampling Line (Pre)

Sampling Dates

Temperature Acceptable

ppm -0.10

Average Temperature °C 2.0

Sampling Times -

-

4.0

± ppm 3.17

< °C

Run Number

Conditioning Unit Temperature Units

OXIDES OF NITROGEN (as NO₂): SAMPLING DETAILS & QUALITY ASSURANCE

Parameter

63.3

CA

L 1

Run 1

Zero Down Sampling Line (Post) ppm -0.10

CA

L 1

CA

L 2

ppm

Units

250

3.17

Span Drift Acceptable - Yes

INPUT

Nature of Deviation

15:31 - 16:00

Allowable Temperature

0.00

Instrument Range

Zero Drift

Zero Down Sampling Line (Pre) ppm

°C

ppm

-

Run 1

Zero Down Sampling Line (Post) ppm

Zero Down Sampling Line (Post)

Yes

ppm

ppm

Units

CA

L 3

Span Drift

Allowable Span Drift

Test Conditions Units Run 1

CA

L 3

Allowable Zero Drift

ppm

± ppm

Zero Drift Acceptable

ppm

Zero Down Sampling Line (Pre)

Span Down Sampling Line (Pre)

Run 1

CAT-RT (Version BO)

Page 70 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 73 of 83

k =

mg/m³

mg/m³

RUN 1 Units

Measurement uncertainty Result 0.88

mg/m³

Uncertainty corrected to std conds. (O₂) 2.19

0.63

% of value

mg/m³ (REF)

mg/m³

0.00

% of full scale

5 %

205.0 mg/m³

Cal gas conc. 63.3 ppm

Conversion 2.05 ppm to mg/m³

MCERTS Range [B] 205.0 mg/m³

Ration NO / NO₂

mg/m³ (STP, dry)Measured concentration

TGN M2 Allowable MU

Limit value

seconds

-

Repeatability at zero 0.00 % full scale

% of value

Zero drift -0.16 % full scale

Atmospheric pressure dependence 0.10 % of value/kPa

Ambient temperature dependence 0.04 % full scale/10K

% full scale

Deviation from linearity 0.29

Span drift -0.63 % full scale

Volume or pressure flow dependence 0.10

2.19

Result of Compliance with Uncertainty Requirement in M2

Uncertainty of calibration gas

Units

% of Value

Range Used [A] 513.1

0.01 mg/m³

Combined interference (from MCERTS Certificate) 0.75

Repeatability at span level 0.10

Performance characteristic RUN 1 Units

Units

Response time 31

mg/m³

mg/m³

Combined uncertainty 1.12

N/A % at ELV

Overall Allowable uncertainty (with O₂) - at 95% Confidence N/A

% full scale/10V

95.5 %

mg/m³

% range

RUN 1

-

Requirement for SRM is that Uncertainty should be <10% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 10% + the

uncertainty associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2.

mg/m³

Standard deviation of repeatability at span level

Dependence on voltage

0.34 mg/m³

Drift -0.12

Losses in the line (leak)

% at ELV

Result of Compliance with Uncertainty Requirement in M2 COMPLIANT -

RUN 1

Volume or pressure flow dependence 0.00

Lower of [A] or [B]

mg/m³

Atmospheric pressure dependence 0.06 mg/m³

mg/m³

Lack of fit

Ambient temperature dependence

mg/m³Converter efficiency

Losses in the line (leak) 0.00 mg/m³

Units

Expanded uncertainty (with O₂) - at 95% Confidence N/A

0.01

mg/m³

Dependence on voltage -0.03

mg/m³

% of value

% of value

0.00

% of Value

Standard deviation of repeatability at zero use rep at span

Expanded uncertainty (no O₂) - at 95% Confidence 248.12

Expanded uncertainty (no O₂) - at 95% Confidence 1.69 % at ELV

Overall Allowable uncertainty (no O₂) - at 95% Confidence 10.0 % at ELV

Performance characteristics RUN 1

ppmRange Used

%

0.88

250.0

mg/m³

mg/m³ (REF)

10.0

130.0

OXIDES OF NITROGEN (as NO₂): MEASUREMENT UNCERTAINTY CALCULATIONS

Combined interference

Expanded uncertainty 1.96

Uncertainty of calibration gas blending 0.01

Uncertainty of calibration gas blending 1.40

Uncertainty of calibration gas 2.00

Expanded uncertainty (with O₂) - at 95% Confidence

N/A

-0.23

Performance characteristics RUN 1

Converter efficiency

Number of readings in measurement 30

0.02

Cal gas conc. 130.0

APPENDIX 2

Units

CAT-RT (Version BO)

Page 71 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 74 of 83

Sample Runs

- -

- -

- -

- -

- -

General Sampling Information

NOTE: Dilution performed to achieve correct span value

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Reference Conditions

Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.

Parameter

Uncertainty

Zero Gas Type

153.9

Yes

Heated Line Temperature 180°C

C1

Heated Head Filter Used

200.8

±mg/m³ 0.95

1.24

200.8

Span Gas Type Carbon Monoxide

Run 1

Number of Sampling Lines Used 1 / 1

Number of Sampling Points Used

Span Gas Expiry Date

1 / 1

Nitrogen (5 Grade)

g/hr

APPENDIX 2

EP 35 - Face Dryer Stage 1

Parameter Units

Medite Europe Ltd, Clonmel

Uncertainty

Concentration

Value

mg/m³ 1.24

Probe Material Titanium

Filtration Type / Size

153.9

Gas Cylinder Concentration (ppm) 409.64

Span Gas Uncertainty (%) 2

Technical Procedure CAT-TP-39

Standard EN 15058

Span Gas Reference Number CYL 2.0097

0.1µm Glass Fibre

0.95

Sample Point I.D.'s

Mean

CARBON MONOXIDE: RESULTS SUMMARY

±g/hr

20/06/2019

Span Gas Start Pressure (bar) 110

Mass Emission

CAT-RT (Version BO)

Page 72 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 75 of 83

Graphical Trend of Data

APPENDIX 2

CARBON MONOXIDE: DATA TREND

COVER ME WITH CHART/S

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

15

:31

15

:32

15

:33

15

:34

15

:35

15

:36

15

:37

15

:38

15

:39

15

:40

15

:41

15

:42

15

:43

15

:44

15

:45

15

:46

15

:47

15

:48

15

:49

15

:50

15

:51

15

:52

15

:53

15

:54

15

:55

15

:56

15

:57

15

:58

15

:59

16

:00

Co

nce

ntr

atio

n (

mg/

m³)

Carbon Monoxide At Reference Conditions

- Run 1

CAT-RT (Version BO)

Page 73 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 76 of 83

Sampling Details

Quality Assurance

Zero Drift 0 0 0

Zero Drift 0 0 0

Zero Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Method Deviations

1

x

- - -

- - -

- - -

ppm

°C 2.0

Span Gas Value

CA

L 1

Units Run 1

Zero Down Sampling Line (Pre)

ppm

ppm

0.50

Span Down Sampling Line (Pre)

Span Drift

Allowable Span Drift ± ppm

(x = deviation applies to the associated run)

There are no deviations associated with the sampling employed.

Run Ambient Temperature Range

Span Down Sampling Line (Post) ppm

Zero Drift Acceptable -

ppm

ppm -3.20

Span Down Sampling Line (Post)

Zero Down Sampling Line (Pre) ppm

Yes

Sampling Times

ppm 406.00

Allowable Zero Drift ± ppm

-

ppm

ppm

0.50

-

Yes

Zero Down Sampling Line (Post)

Units

409.6

ppm

ppm

Run 1

Average Temperature

Allowable Temperature < °C

Zero Down Sampling Line (Pre)

ppm

ppm

Span Down Sampling Line (Pre)

Units

ppm

Run 1

Test Conditions

20.48

Units Run 1

Run Number

Span Down Sampling Line (Pre)

Span Down Sampling Line (Post)

CA

L 2

Temperature Acceptable

Zero Drift

CA

L 3

ppm

Units

APPENDIX 2

CA

L 1

CA

L 2

4.0

CARBON MONOXIDE: SAMPLING DETAILS & QUALITY ASSURANCE

Parameter

Zero Down Sampling Line (Post)

ppm

ppm 0.00

Sampling Dates - INPUT

Instrument Range ppm 500

15:31 - 16:00

Run 1

°C 18 - 19

20.48

Zero Down Sampling Line (Post)

Conditioning Unit Temperature

CA

L 3

409.20

YesSpan Drift Acceptable -

ppm

Nature of Deviation

CAT-RT (Version BO)

Page 74 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 77 of 83

k =

Requirement for SRM is that Uncertainty should be <6% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 6% + the uncertainty

associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2.

Measured concentration

TGN M2 Allowable MU

Limit value

Performance characteristics RUN 1 Units

600.0 mg/m³ (REF)

6.0 %

1.39 mg/m³ (STP, dry)

RUN 1 Units

Expanded uncertainty (no O₂) - at 95% Confidence 76.48

Expanded uncertainty (with O₂) - at 95% Confidence N/A % at ELV

Overall Allowable uncertainty (with O₂) - at 95% Confidence N/A % at ELV

1.06 mg/m³ (REF)

1.06 mg/m³

Uncertainty corrected to std conds. (O₂)

Lack of fit 0.27 mg/m³

Drift 0.35 mg/m³

Volume or pressure flow dependence 0.00 mg/m³

Atmospheric pressure dependence 0.05

Result of Compliance with Uncertainty Requirement in M2 N/A -

Losses in the line (leak) 0.00 mg/m³

Uncertainty of calibration gas blending 0.01 mg/m³

% of Value

Expanded uncertainty (no O₂) - at 95% Confidence 0.18 % at ELV

Overall Allowable uncertainty (no O₂) - at 95% Confidence 6.0 % at ELV

Result of Compliance with Uncertainty Requirement in M2 COMPLIANT -

RUN 1 Units

Expanded uncertainty (with O₂) - at 95% Confidence N/A % of Value

Uncertainty of calibration gas 0.02 mg/m³

RUN 1 Units

Measurement uncertainty Result 1.39 mg/m³

Combined uncertainty 0.54 mg/m³

Expanded uncertainty 1.96

mg/m³

Ambient temperature dependence -0.03 mg/m³

Combined interference (from MCERTS Certificate) -0.21 mg/m³

Dependence on voltage -0.04 mg/m³

% range

Dependence on voltage -0.35 % full scale/10V

Losses in the line (leak) 0.10 % of value

Uncertainty of calibration gas blending 1.40 % of value

Uncertainty of calibration gas 2.00 % of value

Performance characteristic RUN 1 Units

Standard deviation of repeatability at zero use rep at span mg/m³

Standard deviation of repeatability at span level 0.04 mg/m³

Units

Response time 28

% full scale

Repeatability at span level 0.20 % full scale

Deviation from linearity 0.63 % of value

Number of readings in measurement 30

APPENDIX 2

CARBON MONOXIDE: MEASUREMENT UNCERTAINTY CALCULATIONS

% of full scale

Atmospheric pressure dependence 0.22 % of value/kPa

Ambient temperature dependence -0.20 % full scale/10K

ppm

Range Used [A] 624.6 mg/m³

Cal gas conc. 409.6 ppm

Conversion 1.25 ppm to mg/m³

RUN 1

-

Repeatability at zero

Performance characteristics

Zero drift 0.12 % full scale

Span drift -0.78 % full scale

Volume or pressure flow dependence 0.10

mg/m³

Cal gas conc. 511.7 mg/m³

Combined interference -0.48

MCERTS Range [B] 75.0

seconds

Range Used 500.0

mg/m³

Lower of [A] or [B] 75.0

0.10

CAT-RT (Version BO)

Page 75 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 78 of 83

Sample Runs

- -

- -

- -

General Sampling Information

NOTE: Dilution performed to achieve correct span value

FORMAT: Number Used / Number Required

FORMAT: Number Used / Number Required

Span Gas Type Synthetic Air (5 Grade)

Span Gas Reference Number

Units Run 1

Value

Standard

Nitrogen (5 Grade)

Number of Sampling Points Used 1 / 1

Sample Point I.D.'s C1

EN 14789

Technical Procedure CAT-TP-39

Probe Material Titanium

Filtration Type / Size

Span Gas Expiry Date 07/12/2020

Span Gas Start Pressure (bar) 80

Gas Cylinder Concentration (% v/v) 21.67

Number of Sampling Lines Used 1 / 1

Parameter Mean

Parameter

180°C

Span Gas Uncertainty (%) 2

Zero Gas Type

0.1µm Glass Fibre

Heated Head Filter Used Yes

Heated Line Temperature

Uncertainty ±% v/v 0.49 0.49

CYL 11.0228

APPENDIX 2

Medite Europe Ltd, Clonmel

EP 35 - Face Dryer Stage 1

Concentration % v/v 19.63 19.63

OXYGEN: RESULTS SUMMARY

CAT-RT (Version BO)

Page 76 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 79 of 83

Graphical Trend of Data

OXYGEN: DATA TREND

APPENDIX 2

COVER ME WITH CHART/S

0.0

5.0

10.0

15.0

20.0

25.0

15

:31

15

:32

15

:33

15

:34

15

:35

15

:36

15

:37

15

:38

15

:39

15

:40

15

:41

15

:42

15

:43

15

:44

15

:45

15

:46

15

:47

15

:48

15

:49

15

:50

15

:51

15

:52

15

:53

15

:54

15

:55

15

:56

15

:57

15

:58

15

:59

16

:00

Co

nce

ntr

atio

n (

% v

/v)

Oxygen Oxygen

- Run 1

CAT-RT (Version BO)

Page 77 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 80 of 83

Sampling Details

Quality Assurance

Zero Drift 0 0 0

Zero Drift 0 0 0

Zero Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Span Drift 0 0 0

Method Deviations

1

x

- - -

- - -

- - -

Zero Down Sampling Line (Post)

% v/v

% v/v

CA

L 3

4.0

-0.09

Zero Down Sampling Line (Pre) % v/v

CA

L 1

Zero Down Sampling Line (Pre) % v/v

-

Conditioning Unit Temperature Units Run 1

15:31 - 16:00

Parameter

Span Gas Value

Run 1

Span Down Sampling Line (Post) % v/v

Allowable Temperature < °C

0.03

Zero Down Sampling Line (Post) % v/v -0.06

Units Run 1

Sampling Times

Average Temperature

CA

L 2

Zero Down Sampling Line (Pre) % v/v

Zero Drift Acceptable

Instrument Range % v/v 25

Span Down Sampling Line (Post) % v/v

CA

L 3

-

Nature of Deviation

Temperature Acceptable - Yes

Span Drift Units

Run Number

(x = deviation applies to the associated run)

There are no deviations associated with the sampling employed.

% v/v

Allowable Span Drift ± % v/v 1.08

°C 2.0

Yes

Units Run 1

Span Drift Acceptable - Yes

Test Conditions Units Run 1

Run Ambient Temperature Range °C 18 - 19

CA

L 2

Span Down Sampling Line (Pre) % v/v

Span Down Sampling Line (Post) % v/v

% v/v

% v/v

21.83

% v/v

Zero Down Sampling Line (Post)

% v/v

% v/v

21.94

Span Down Sampling Line (Pre) % v/v

APPENDIX 2

OXYGEN: SAMPLING DETAILS & QUALITY ASSURANCE

% v/v 21.67

% v/v -0.11

Allowable Zero Drift ± % v/v 1.08

Zero Drift

CA

L 1

Span Down Sampling Line (Pre)

Sampling Dates - INPUT

CAT-RT (Version BO)

Page 78 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 81 of 83

k =

% range

Dependence on voltage 0.02 % full scale/10V

Losses in the line (leak) 0.00 % of value

Uncertainty of calibration gas

2.50 % of Value

Result of Compliance with Uncertainty Requirement in M2 COMPLIANT -

Expanded uncertainty 1.96 0.55 %vol

RUN 1 Units

Standard deviation of repeatability at zero use rep at span %vol

Standard deviation of repeatability at span level 0.00 %vol

Lack of fit 0.00 %vol

Drift -0.11 %vol

Volume or pressure flow dependence 0.00 %vol

Atmospheric pressure dependence %vol

Ambient temperature dependence -0.03 %vol

N/A %vol

6.0 %

0.01

Requirement for SRM is that Uncertainty should be 0.5%vol absolute or 6% relative whichever is the lower, on a dry gas basis. Ref EA TGN M2.

Combined interference (from MCERTS Certificate) 0.00 %vol

Dependence on voltage 0.00 %vol

Losses in the line (leak) 0.00 %vol

Uncertainty of calibration gas 0.25 %vol

RUN 1 Units

Measurement uncertainty Result 21.97 %vol

Combined uncertainty 0.28 %vol

-0.21 % full scale/10K

Atmospheric pressure dependence 0.19 % of value/kPa

Ambient temperature dependence

Volume or pressure flow dependence 0.10

2.00

Expanded uncertainty (no O₂) - at 95% Confidence

% of full scale

Number of readings in measurement 30 -

Repeatability at zero 0.02 % full scale

Repeatability at span level 0.02 % full scale

Deviation from linearity

% full scale

Span drift -0.50 % full scale

21.97 %vol

Range Used 25.0 %vol

Cal gas conc. 21.7 %vol

Performance characteristics RUN 1 Units

Response time 41 seconds

Combined interference 0.00

Performance characteristics RUN 1 Units

Measured concentration

TGN M2 Allowable MU

Limit value

% of value

Performance characteristic RUN 1 Units

0.03 % of value

Zero drift -0.41

APPENDIX 2

OXYGEN: MEASUREMENT UNCERTAINTY CALCULATIONS

CAT-RT (Version BO)

Page 79 of 79

Medite Europe Ltd

Clonmel

EP 35 - Face Dryer Stage 1

Job Number: CDU-0666-CAR16-01, Version 1

Sample Date/s: 26th - 27th July 2016

Industrial Emissions Licence: P0027-02

Site Visit Report - SV08076 - Medite Europe Limited Page 82 of 83

Summary

See report

FOLLOW-UP ACTIONS

You are required to complete the instructions and actions, as outlined in this report, within the specified timeframe. Where required, you shall respond to actions specified in Compliance Investigations within the required timeframe. The licensee shall maintain documentary evidence, for review by the EPA, that the prescribed corrective actions were completed within the required timeframe.

You are not required to respond directly to items contained in this EPA site visit report; where an issue requires a direct response, the EPA will generate a Compliance Investigation through the EDEN system. You will receive notification when a Compliance Investigation instruction or action is generated.

Please note that this Site Visit Report will be made available for public viewing via the EPA’s Licence Enforcement Access Portal within one day of the issue date and will be published on the Licence Details Page of the EPA’s website, www.epa.ie, that relates to your licence 60 calendar days after the issue date.

You may if you choose submit, within 45 calendar days of the issue date of this Site Visit Report, a Licensee Public Response that will be published alongside the Site Visit Report. This Response, should you wish to avail of it, provides you with an opportunity to inform the public about how you are implementing the actions set out in the report, activities underway, timescales and target completion dates. Please be aware that the content of your Licensee Public Response must be factual and should not breach the EPAs stated online publication standards.

If you wish to submit a Licensee Public Response to an EPA Site Visit Report, you should do this by clicking on the ‘Make a Response’ link on the Site Visits page in EDEN. A .pdf document containing your response can be attached and submitted from here.

Please note that you are required to comply with the conditions of your licence at all times, and where noncompliance occurs you must restore compliance within the shortest possible time. These actions will be verified during subsequent EPA visits.

Please quote the above Inspection Reference Number in any future correspondence in relation to this Report.

Site Visit Report - SV08076 - Medite Europe Limited Page 83 of 83