4
LOW-PROFILE: SINGLE/MULTI-FAMILY, LIGHT COMMERCIAL SL SERIES ERVs VENTILATION SOLUTIONS FOR EVERY APPLICATION u Low-profile, commercial-grade appliance, often used for multi- family units u 51-76 CFM continuous mode, 76-94 CFM boost mode and four-duct configuration u EC motors, boost mode capability, Dial-A-Flow controls, MERV 13 filter option u Hard-wired power (SL70H) or plug-in power (SL70L)

SL SERIES ERVs - ERV Direct · MERV 8 FILTER CLEANABLE FOIL-FACED INSULATION LINE CORD OR HARD WIRE 3 4 SL70L SL70H POWER SUPPLY Line cord Hard wire* CONTINUOUS MODE 51-76 CFM BOOST

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SL SERIES ERVs - ERV Direct · MERV 8 FILTER CLEANABLE FOIL-FACED INSULATION LINE CORD OR HARD WIRE 3 4 SL70L SL70H POWER SUPPLY Line cord Hard wire* CONTINUOUS MODE 51-76 CFM BOOST

LOW-PROFILE: SINGLE/MULTI-FAMILY, LIGHT COMMERCIAL

SL SERIES ERVs

VENTILATION SOLUTIONS FOR EVERY APPLICATION

u Low-profile, commercial-grade

appliance, often used for multi-

family units

u 51-76 CFM continuous mode,

76-94 CFM boost mode and

four-duct configuration

u EC motors, boost mode capability,

Dial-A-Flow controls, MERV 13 filter option

u Hard-wired power (SL70H)

or plug-in power (SL70L)

Page 2: SL SERIES ERVs - ERV Direct · MERV 8 FILTER CLEANABLE FOIL-FACED INSULATION LINE CORD OR HARD WIRE 3 4 SL70L SL70H POWER SUPPLY Line cord Hard wire* CONTINUOUS MODE 51-76 CFM BOOST

2

SL SERIES LOW-PROFILE : S INGLE/MULT I -FAMILY, L IGHT COMMERCIAL ERV

SL SER IES In response to growing demand for smaller and more flexible units, we are introducing the RenewAire Slimline ERV SL Series. The ETL Listed and HVI-Certified Slimline is compact, fits into tight spaces and can be adjusted to a specific point by one (1) CFM increments to vary supply and exhaust airflows. It can also operate continuously at that low airflow with a boost-mode option for temporarily high airflow. It is the perfect ERV for high-rise condos, apartments, townhouses, residential homes, compartmentalized commercial spaces with minimal bulkhead and ceiling space, and Passive House.

BOOST MODE Two-speed functionality for continous low/high flow.

ASHRAE 62 .2 The American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) revised Standard 62.2. The revision continued to evaluate every building’s minimum ventilation needs, but also placed a greater emphasis on indoor air quality and its role on health.

VENTILATION AIRFLOW REQUIRED BY HOME SIZEUse formula below to calculate the minimum ventilation required: .03 x sq. ft. + 7.5(bedroom +1)

FLOOR AREA, FT2

<500 501-1000 1001-1500 1501-2000 2001-2500 2501-3000 3001-3500 3501-4000

1 BEDROOM 30 45 60 75 90 105 120 135

2 BEDROOMS 38 53 68 83 98 113 128 143

3 BEDROOMS 45 60 75 90 105 120 135 150

4 BEDROOMS 53 68 83 98 113 128 143 158

5 BEDROOMS 60 75 90 105 120 135 150 165

BALANCED VENT ILAT ION & INDOOR A IR QUAL ITY As new buildings get tighter to seal weather out, they seal in contaminants, causing deficient indoor air quality (IAQ). Since people spend, on average, 90% of their time indoors1, and indoor air can be two to five times—and up to 100 times—more polluted than outdoor air,2 indoor air quality has very real impacts on health and cognitive function.

HIGHEST-QUAL ITY INDOOR A IR Our SL Series ERVs can improve indoor air quality by removing contaminants, such as off-gassing from carpeting, furniture and building materials, excess humidity and mold. Our technology takes stale indoor air and replaces it with fresh, conditioned and filtered outdoor air.

APPL ICAT IONS Available in two models, SL70L and SL70H, the Slimline is a low-profile ERV capable of fitting in bulkheads and drop-down ceilings. The Slimline series can be installed vertically, horizontally or at any angle to suit site restrictions. This makes the SL series perfect for applications that have restrictive space for installation.

OPTIMIZE ENERGY EFFICIENCY u Preconditions incoming air with otherwise-wasted total energy (heat and humidity) of the exhaust air going out

IN SUMMER, THE WARM, HUMID OUTSIDE AIR IS PRECOOLED AND DEHUMIDIFIED BY THE OUTGOING COOL INTERIOR AIR

IN WINTER, THE COLD, DRY OUTSIDE AIR IS PREHEATED AND HUMIDIFIED BY THE OUTGOING WARM INTERIOR AIR

RENEWAIRE CORE TECHNOLOGY

CERTIFICATION u Ensures no exhaust-airstream contaminants enter the fresh airstream,

which is maintained by airstream physical separation across the core membrane

u Superior core flammability performance; passes UL-723 and UL-1812

MAINTENANCEu RenewAire cores are easy to clean without removing them from the unit,

and they never require washing

INNOVATIVE CONSTRUCTIONu Core exchanger material is cellulosic-based and does not contain or use

halogenated flame retardants or PVCs

u Manufactured with a galvanized steel frame

EXCEPTIONAL PERFORMANCEu Transfers both heat and humidity

u Certified by the Air Conditioning, Heating and Refrigeration Institute (AHRI) for an industry leading low-to-zero Exhaust Air Transfer Ratio (EATR) at typical static pressure differentials

u No need for frost protection or condensate pans

u Laminar airflow ensures that particulates do not accumulate in the core

REDUCED COSTS u Optimized energy efficiency via core energy transfer decreases ventilation

energy requirements, which can result in smaller air conditioning and heating needs

LOW-VOLTAGE

CIRCUIT FOR CONTROLS

DIAL-A-FLOW (Balance and airflow

adjustment)

MERV 8 FILTER

(MERV 13 shown, available as

an accessory)

48V DC MOTORIZED IMPELLER PACKAGES

ENERGY RECOVERY

CORE

6" DUCT COLLAR

MERV 8 FILTER

CLEANABLE FOIL-FACED INSULATION

LINE CORD OR

HARD WIRE

43

SL70L SL70HPOWER SUPPLY Line cord Hard wire*

CONTINUOUS MODE 51-76 CFM

BOOST MODE 76-94 CFM

LENGTH 27 1/4"

WIDTH 20 3/8"

HEIGHT 9 1/2"

WEIGHT 32 lbs.

MOUNT Ceiling Bracket or Hanging Chain

EC MOTOR Yes

FILTER MERV 8, MERV 13 (supply outside air only for MERV 13)

CORE WARRANTY 10-year

UNIT WARRANTY 5-year

CERTIFICATIONS

FAN EFFICIENCY 1.8 CFM/watt at 53 CFM

*ELECTRICAL POWER TO BE HARD-WIRED IN FIELD BY CONTRACTOR

AIRSTREAMS DO NOT MIX & POLLUTANTS ARE NOT TRANSFERRED

ACROSS PARTITION PLATES

Stale Room Air Outside Air

INSIDE Fresh Air Enters

OUTSIDE Stale Room Air Exits

Fixed Partition and Spacer Plates (proprietary resin and composite media)

0.00

0.20

0.40

0.60

0.80

1.00

1.20

30 40 50 60 70 80 90 100 110 120

Exte

rnal

Sta

tic P

ress

ure

(in. w

.g.)

Airflow (cfm)

SL70 Performance Curve

BOOST MODE

System

Curve

CONTINUOUS MODE

1 “Indoor Air Pollution: Introduction for Health Professionals,” U.S. Consumer Product Safety Commission, https://www.cpsc.gov/safety-education/safety-guides/home/indoor-air-pollution-introduction-health-professionals.

2 “Why Indoor Air Quality is Important to Schools,” U.S. Environmental Protection Agency (EPA), https://www.epa.gov/iaq-schools/why-indoor-air-quality-important-schools.

Page 3: SL SERIES ERVs - ERV Direct · MERV 8 FILTER CLEANABLE FOIL-FACED INSULATION LINE CORD OR HARD WIRE 3 4 SL70L SL70H POWER SUPPLY Line cord Hard wire* CONTINUOUS MODE 51-76 CFM BOOST

5

Wall-Bracket Kit

F ILTERS

MERV 13 Filters OA Airstream Wall Cap 6” White or Brown

MOUNTS WALL CAPS

Push-Button, Point-Of-Use Timer (PBL)

Percentage Tmer (PTL) Percentage Timer with Furnace Interlock (FM)

Occupancy Sensor Wall Mount CO2 Sensor Wall MountIAQ Sensor Wall Mount

Occupancy Sensor Ceiling Mount Digital Time Clock Wall Mount Digital Time Clock Exterior Enclosure

CONTROLS

Backdraft Damper

DAMPERS

RH Series Electric Duct Heater 1kW, 2kW, 3kW, 4kW

HEATERS

ACCESSORIES

Page 4: SL SERIES ERVs - ERV Direct · MERV 8 FILTER CLEANABLE FOIL-FACED INSULATION LINE CORD OR HARD WIRE 3 4 SL70L SL70H POWER SUPPLY Line cord Hard wire* CONTINUOUS MODE 51-76 CFM BOOST

MAINTENANCE Disposable filters should be checked and replaced as needed. Additionally, once a year, vacuum the four core faces using a soft brush. The RenewAire core does not need to be washed, as particulates do not accumulate in the core.

RenewAire.com 800.627.4499 LIT118_01 (05/19)

SL SERIES

RenewAire ERVs can be applied everywhere across all residential and commercial buildings,

and everything in between. Our technology excels in every geographic region,

every climate and every size project.

RENEWAIRE EVERYWHERE

The Slimline is simple to install and its operation is a breeze

u Four 6" duct collars for easy duct connection

u Easy integration with existing or new forced-air furnace ducting or for stand-alone applications

u Adjustable brackets and screws for easy and quick installation

u Spring isolators are provided for hanging chain mount

INSTALLAT ION

Hanging Chain MountCeiling Bracket Mount