Slant TEC data ingestion in the Modified NeQuick ionosphere electron density model. B. Nava, S.M. Radicella, R. Leitinger and P.Coïsson The Abdus Salam ICTP, Trieste, Italy IGAM, Graz, Austria XXVIII General Assembly of International Union of Radio Science - PowerPoint PPT Presentation
Citation preview
B. Nava, S.M. Radicella, R. Leitinger and P.Coïsson The Abdus Salam ICTP, Trieste, ItalyIGAM, Graz, Austria
XXVIII General Assembly of International Union of Radio ScienceNew Delhi, India October 23-29, 2005
Slant TEC data ingestion in theModified NeQuickionosphere electron density model
The abdus salam international centre for theoretical physics
• Introduction• NeQuick model and Modified NeQuick model description
• Slant TEC data ingestion• Electron density reconstruction technique (concepts)
• The Modified NeQuick performance• Evaluation criteria• Data used• Data analysis
• Conclusions
Outline
The abdus salam international centre for theoretical physics
•NeQuick is an ionospheric electron concentration model able to give the electron density distribution on both the bottomside and topside of the ionosphere.
•The model formulation includes 6 semi-Epstein layers with modeled thickness parameters and is based on anchor points defined by foE, foF1, foF2 and M(3000)F2 values.
•These values can be modeled (e.g. ITU-R coefficients for foF2, M(3000)F2) or experimentally derived.
•The NeQuick topside formulation is based on an empirical k parameter, that controls the topside profile shape and depends on the month of the year.
•NeQuick inputs are: position, time and solar flux; the output is the electron concentration at the given location and time.
Introduction (NeQuick)
The abdus salam international centre for theoretical physics
•The Modified NeQuick topside formulation is based on an empirical k’ parameter that does not depend on the month of the year and therefore it is a simplification of the previous one (ICTP).
•foF2 and hmF2 (instead of foF2 and M(3000)F2) are modeled using a new mapping procedure, based on simplified ITU-R maps “CCsim” (IGAM University of Graz).
•M(3000)F2 is recovered “inverting” the Dudeney formula for hmF2 and it is used only as internal parameter.
Introduction (modified NeQuick)
The abdus salam international centre for theoretical physics
Slant TEC data ingestion
NeQuick + ITU-R [or “CCsim”] coefficients + F10.7
Climate representation of the ionosphere
Weather specification of the ionosphere
NeQuick + ITU-R [or “CCsim”] coefficients + effective ionization level
The abdus salam international centre for theoretical physics
Slant TEC data ingestionAt a given epoch
Minimize each mismodeling
m sTECexp (several stations & satellites)
Az jScattered Interpolate to get regularly spaced grid
Use NeQuick to reconstruct the 3D electron density of the ionosphere
Reconstruct TEC along any given ray-path
Reconstruct any foF2 value (foF2 map)
The abdus salam international centre for theoretical physics
Model performance evaluationCriteria:
Data used:
Data analysis:
comparison between experimental and reconstructed sTEC (self consistency of the reconstruction method)
comparison between experimental and reconstructed foF2 (independent crosscheck with ionosonde data)
Super-truth sTEC data from 25 ground stations & foF2 data from 6 ionosondes at 15 min. time intervalfor the days 27 March, 5 April, 6 June 2000(undisturbed days in high solar activity)
cumulative distributions of the absolute values of the differences between experimental and reconstructed sTEC data and foF2 data
The abdus salam international centre for theoretical physics
Stations & ionosondes locations
Super-truth stationsIonosondes
Modip isolines
The abdus salam international centre for theoretical physics
Results: sTEC & foF2, day 000327
NeQuick Modified NeQuick
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Results: NmF2, day 000327
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Results: sTEC & foF2, day 000405
NeQuick Modified NeQuick
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Results: NmF2, day 000405
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Results: sTEC & foF2, day 000607
NeQuick Modified NeQuick
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Results: NmF2, day 000607
NeQuick Modified NeQuick
The abdus salam international centre for theoretical physics
Conclusions• NeQuick model has been modified. The impact of the changes
has been tested using an electron density reconstruction technique previously developed by the authors. This technique, based on slant TEC data ingestion, has been applied to NeQuick and Modified NeQuick models.
• The results obtained show that the Modified NeQuick model allows a better reconstruction of the ionosphere in terms of TEC, if compared with NeQuick model. Not substantial changes are observed in terms of foF2.
• Since NeQuick has been developed to be used in single frequency positioning applications, where TEC is the most important parameter to be modeled, the Modified NeQuick model can be considered an improvement with respect to Nequick.
The abdus salam international centre for theoretical physics
Acknowledgments
The authors are grateful to the WAAS community from whom they received the “Supertruth” data used for the present study and to the Center for Atmospheric Research of the University of Massachusetts at Lowell, for providing access to the digital ionogram data base (DIDBase).
The abdus salam international centre for theoretical physics
Thank you for your attention
The abdus salam international centre for theoretical physics