Smart Solutions for Remote Monitoring and Alarms Active Ethernet I/O with Active OPC Server
• Genuine PC-free solutions for monitor and alarm systems
• Zero programming with menu-driven logic configurations
• Active alarm message reports with precise time stamps
• Support SMS/SNMP traps/e-mail/TCP/UDP/CGI commands
• Easy integration with Active OPC Server and DLL library
Vol. 91
• Distributed Active Ethernet I/O• Modular Active Ethernet I/O• Active GPRS I/O
Active Ethernet I/O
Intrusion Detection and Alarm SystemsMoxa’s ioLogik Active Ethernet I/O is a perfect solution for large facility intrusion detection systems. The ioLogik’s built-in intelligence allows the I/O device to monitor intrusion signals from motion, tilt, and optic sensors, as well as send out real-time alarms. A typical application is an airport intrusion detection and alarm system. Security around airport runways and terminals require instant alarm notices to be sent to the control center for rapid security response. The ioLogik can proactively send out alarm messages to the control center, ensuring real-time acquisition of intrusion alerts. Alarms are always reported so system administrators don’t need to worry about dropped alarms, such as the case with traditional polling mechanisms. Thanks to Click&GoTM logic, the ioLogik is also capable of local alarm control.
Application Requirements
• Alarm retrieval from distributed sensors over vast areas• Instant alarms and intrusion reports• Local intelligent for local alarms• Ease of use, integration, and maintenance
Unmanned Facility MonitoringWith local intelligence and versatile active reporting communication protocols, the ioLogik is practically tailor-made for unmanned facility monitoring. The ioLogik can be used to monitor intrusion, humidity, temperature, power supply, gas exhaustion and fuel tank levels, power generator status, and actively update I/O tags to the central SCADA system with Active OPC Server. Active OPC Server is also designed to solve dynamic and private IP issues in GPRS communication. That is, users no longer need to purchase a fixed public IP SIM card. The Active OPC Server will take care of the communication from SCADA to field device, making installation and project implementation easier. Moreover, the active report method also makes data communication over wireless networks possible. Users can enjoy the benefits of real-time event monitoring without worrying about network bandwidth issues.
Application Requirements
• Data transmission in low bandwidth environments• Instant alarm reports• Local intelligence for local alarms• Ease of use, integration, and maintenance
Water and Waste Water Treatment Monitoring and Control SystemThe growing awareness of environmental protection has made water and wastewater treatment a rapid growing business around the world. Water distribution or waste water collection systems need to monitor various factors including pump status, water pressure, tank level, water volume, valve status, power status, and CSO (combined sewage overflow). With its local control capability, the ioLogik is able to provide water and wastewater monitoring systems with pump control and power management.
Application Requirements
• Data collection over a vast area• Local pump control and power management • Easy integration with a SCADA system• PC-free module control over the network
An Ideal Solution for Versatile Remote Monitoring & Alarm Systems
1
• Intrusion alarms and instant active reports• No dropped alarms• Active alarm message reports with precise time
stamps• Versatile alarm media with TCP/UDP/SNMP
trap/email/CGI command/Active OPC server• DI to DO local intelligence control for local
alarms• Menu-driven control logic setting reduces
maintenance effort
• Quad-band GPRS• Real-time I/O status active update• Versatile alarm media with TCP/UDP/SNMP trap/
email/SMS• Menu-driven control logic setting reduces
maintenance effort• Dynamic and private IP issue resolved with Active
OPC Server• One RS-232/422/485 port for serial-to-GPRS
communication• SD card for data logging• Off-line alarm buffering
• Active alarm messaging• Versatile alarm media with TCP/UDP/SNMP trap/
email/SMS/CGI command• Module to module control with remote action
functionality for a genuine PC-free solution• Menu-driven control logic setting reduces
maintenance effort• Editable email and SMS messaging to multiple
receivers
ioLogik W5340Active GPRS Ethernet I/O(4 AIs, 8 DIOs, 2 relays)
ioLogik E2214Active Ethernet I/O(6 DIs, 6 relays)
ioLogik E4200Modular Active Ethernet I/O
An Ideal Solution for Versatile Remote Monitoring & Alarm Systems
Airport Intrusion Detection and Alarm System
Unmanned Site Monitoring and Alarms
Water Pumping Station Monitoring
2
Click&Go Logic
More Power and Flexibility with the New Generation Click&Go Logic
IF-THEN-ELSE Since IF-THEN-ELSE statements are a fundamental part of any programming language, even an untrained engineer will be able to use Click&Go’s intuitive IF-THEN-ELSE configuration format to finish an I/O configuration in under five minutes.
Compared with the previous version of Click&Go, more functions are supported for each IF-THEN-ELSE description. See the table on page 4 for details.
Remote ActionProgrammers sometimes need to trigger remote digital output based on local analog values. In the example shown here, a water level sensor was installed in a water tower. When the water level drops below a preset level, the analog signal from the sensor will be converted to a remote digital output, which triggers the pump to turn on. Although this is a relatively simple example, Click&Go can handle different set points and trigger conditions.
Benefits:• Only two modules needed without extra PC or controller• Easy to configure• Flexible action and condition settings
E2240
E2210Pump
Reservior
RemoteAction
Water Level Sensor
Water Pipeline
Analog Input
Digital Output
3
More Power and Flexibility with the New Generation Click&Go Logic
Functions
IF THEN ELSE
DI DO DO
Relay/Counter Relay/Pulse Relay/Pulse
Internal Register Internal Register Internal Register
Remote Action Remote Action Remote Action
Timer Timer Timer
Schedule SNMP Trap SNMP Trap
Host Communication Failure Active Message Active Message
E-mail E-mail
CGI Command CGI Command
SMS SMS
TimerClick&Go supports 24 timers in the control logic. Uers can define these timers for different kinds of applications such as a delay timer (delay_on, delay_off, on_delay, off_delay) or timer counter. All time-based control systems can use this function.
Benefits:• Time-based control capability• Flexibility for actions with the timer function
Internal RegisterTwenty-four Modbus registers are available for a user’s application, and users can change a Modbus address from the SCADA software even when Click&Go is running. The diagram at the right shows how to use SCADA/custom software to change the internal register with Modbus/TCP protocol. With this function, users can easily integrate the Active Ethernet I/O product with their control system. Anywhere from 0 to 255 trigger conditions can be defined, and when the trigger condition equals the Modbus value, Action will start running the user’s pre-defined actions.
Benefits:
• Click&Go logic is compatible with SCADA software
• DO can be controlled when Click&Go is running
• Cascade different control rules with internal registers
Modbus Value
0X0178 2
0X0179 255
0X0180 128
Combine Click&Go and Trigger Condition then do an action.
If the internal register contains the “Trigger condition,” then the ioLogik will start the actions predefined in the Click&Go logic.
Modbus/TCPSCADA Software
Custom Software
ScheduleThe fuel shortage is a hot issue for businesses around the world, making saving energy an increasingly important topic for more and more people. For example, automatically turning off lights when they are not in use is a simple, but effective way to save energy. The control device is a key component of automatic light control applications, and Moxa’s Active Ethernet I/O products provide a schedule function to help users with this task. Technicians can easily and quickly use the schedule function to define a periodic control scheme. The schedule function can also be used for lighting, sprinklers, and heating systems. Note that both the time of day and date can be included as part of the control schedule.
Benefits:• Flexibility for periodic control• Customer definable
4
Click&Go Logic
CGI Commands
The IP camera can send CGI commands to trigger output channels on Moxa’s Active
Ethernet I/O products.
The Active Ethernet I/O product can send CGI commands to trigger an IP camera to take a snapshot or rotate
to different viewing angle.
Surveillance Software SCADA
DI DI DO DO
Active Ethernet I/O vs. Remote I/0 Active Ethernet I/O Remote I/O
ProtocolsModbus for IA engineersSNMP/TCP/UDP/e-mail /CGI Commands for IT engineers
Modbus
Communication Architechure
Supports push and pull architecture(Push technology uses TCP, UDP, SNMP trap, email, and Active OPC Server)
Pull
Local Control Capability
• Click&Go logic• No programming effort required• Menu driven
N/A
Interface Ethernet/GPRS Ethernet
Solution Standalone solution PLC components
Winner
CGI commands are based on the HTTP protocol, which is the most popular protocol for accessing the Internet. Users will be able to access Moxa’s I/O devices from anywhere with a simple web browser, and can even communicate through firewalls. Software developers can use CGI commands to integrate I/O functions into their software, which is often used with IP surveillance systems. Moxa’s Active Ethernet I/O products can both send out and receive CGI commands, and for this reason are compatible with surveillance devices that support CGI commands.
Benefits:
• Easy to integrate with web-based software• Firewall friendly• Control I/O from anywhere via web browser
More Power and Flexibility with the New Generation Click&Go Logic
DLL Library
The ioLogik includes VB, VC, BCB and .Net libraries to allow AP developers to shorten development time and reduce costs.
Benefits:• Shortened development time• Reduced development costs
Custom AP
Custom AP
VB, VC, BCB and
.Net Libraries
55
More Power and Flexibility with the New Generation Click&Go Logic
Active OPC Server can reduce network traffic by at least 50%
Upgrade yourHMI/SCADA systemwith the brand-newActive architecture
By adopting Moxa’s Active OPC Server, users don’t need to create tags one by one. With ioAdmin, you can save time by uploading I/O configurations automatically.
Push Technologies Bring Intelligence to Your SensorsTraditional sensor I/O data acquisition requires polling from a central SCADA system and HMI. This method not only increases system burden, but also requires polling settings on the SCADA or HMI. By utilizing push technologies, or report by exception, the ioLogik enables an event response sensor system and transforms network sensors into intelligent devices that allow system integrators to save valuable time in deployment and programming. The ioLogik supports various kinds of active communication interfaces including TCP, UDP, CGI command, email, SMS, SNMP trap, and Active OPC Server.
Upgrade Your SCADA from “Pull” to “Push” Traditionally, OPC servers only support the “pull” architecture for I/O devices. This means that your SCADA system would use a continuous polling method to collect relevant data. Moxa’s Active OPC Server with non-polling architecture supports the standard OPC protocol, but also offers event-driven, active (or “push”) communication with I/O devices to provide real-time signals when the I/O status is changed. You will be able to efficiently reduce data traffic and make use of this optimal bandwidth-saving solution.
By adopting Moxa’s Active OPC Server, users don’t need to create tags one by one. With ioAdmin, you can save time by uploading I/O configurations automatically.
15+ steps to create 1 tag
Click
Just 1 click to create 20 or more tags
With Moxa Active OPCWith Traditional OPC
Active Tag Update
6
Product Showcase
Active Ethernet I/O The Smart Choice for Remote Monitoring and Alarms
ioLogik W5340 Active GPRS Ethernet I/O
Product Features:• 4 AIs, 8 software configurable DIOs, 2 relays
• Quad-band GPRS
• Programming free IF-THEN-ELSE configuration method, increases time-to-market
• Versatile alarm media with TCP/UDP/SMS/email/SNMP trap
• SD card for data logging
• Off-line alarm buffering
• Built-in Web Console
• One RS-232/422/485 port for serial-to-GPRS communication
Active OPC Server resolves private IP communication issues in GPRS environments
The biggest issue for data acquisition over GPRS networks involves the constant changing of private IP addresses. This makes the implementation of a GPRS solution difficult because the user needs to pay extra fees for a MDVPN, mobile data virtual private network service, or get a public and fixed IP address. To solve this problem, the ioLogik W5340 is equipped with Active OPC Server so users don’t need to worry about what kind of IP address they get from the internet service providers. Just install the SIM card and your GPRS solution is ready to go!
77
ioLogik E4200 Modular Active Ethernet I/O
Active Ethernet I/O The Smart Choice for Remote Monitoring and Alarms
Product Features:• Compact size, slice type form factor for maximum I/O combination
flexibility
• Dual LANs for communication redundancy
• One RS-232 port for SMS alarms
• Programming-free IF-THEN-ELSE logic reduces time to market
• Off-line alarm buffering
Dual LANs enhance communication redundancy
For a remote monitoring and alarm system, the most important consideration is to make sure the alarm can be acquired accurately and immediately. The ioLogik E4200’s active report feature provides real-time monitoring capability and achieves communication reliability with a dual LAN design to establish a redundant monitoring and alarm system.
8
Selection Guide
Smarter Sensors and Easier I/O Acquisition
Moxa ioLogik Active Ethernet I/O Family
Analog Modules
ioLogik E2242 (4 AIs, 12 DIOs)• Software configurable DI or DO
channels• +/-150 mV, 0 to 150 mV, +/-500 mV, 0
to 500 mV, +/-5 V, 0 to 5 V, +/-10 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA
• Adjustable sampling rate
ioLogik E2240 (8 AIs, 2 AOs)• +/-150 mV, +/-500 mV, +/-5 V, +/-10 V,
0 to 20 mA, 4 to 20 mA• Adjustable sampling rate• AI to AO signal replication over IP
ioLogik E2212 (8 DIs, 8 DOs, 4 DIOs)• Software configurable DI or DO channels• Dry contact or wet contact (PNP/NPN)
supported
ioLogik E2262 (8 TC inputs, 4 DOs)• Supports J, K, T, E, R, S, B, N types TC and mV• Built-in sensor temperature mapping tables• 16-bit resolution
ioLogik E2260 (6 RTDs, 4 DOs)• Pt, JPt, Ni and RTD sensor supported• Built-in sensor temperature mapping tables• 16-bit resolution
Digital Modules
Temperature Modules
Ease of Use• Programming-free IF-THEN-ELSE control logic• Manu-driven configuration interface• Web console
Ease of integration• DLL Library SDK• Active OPC Server no OPC tag creation needed• CGI command for web-based SCADA
Versatle Communication Methods• TCP/UDP• CGI Command• eMail• SNMP trap
Push Technology• I/O event report by exception• Built-in RTC to provide precise timestamps for alarm
messages• Save bandwidth by 80%• Increase response time by 7 times
9
9
ioLogik E2210 (12 DIs, 8 DOs)• DI or counter mode supported• Dry contact or wet contact (NPN) DO or pulse
output
ioLogik E2214 (6 DIs, 6 relays)• 6 Form A relays• Relay: 5A/250 VAC or 5A/30 VDC• Relay counter for relay usage monitor
GPRS Module
ioLogik W5340 (4 AIs, 8 DIOs, 2 relays)• Quad-band GPRS• +/-150 mV, +/-500 mV, +/-5 V, +/-10 V, 0 to
20 mA, 4 to 20 mA• Data logging
ioLogik E4200 Modular I/O• Supports up to 16 I/O modules (DI/O 256 points or AI/O
up to 64 points)• Dual LANs for network redundancy• SMS alarms
Analog Modules• M-3802 8 AI, 4 to 20 mA, 12-bit• M-3810 8 AI, 0 to 10V, 12-bit• M-4402 4 AI, 4 to 20 mA, 12-bit• M-4410 4 AO, 0 to 10V, 12-bit• M-6200 2 AI, RTD• M-6201 2 AI, thermocouple
Digital Modules• M-1450 4 DI, 110 VAC • M-1451 4 DI, 220 VAC• M-1600 16 DI, sink, 24 VDC• M-1601 16 DI, source, 24 VDC• M-1800 8 DI, sink, 24 VDC• M-1801 8 DI, source, 24 VDC• M-2450 4 Relay outputs, 24 VDC/230VAC• M-2600 16 DO, sink, 24 VDC• M-2601 16 DO, source, 24 VDC• M-2800 8 DO, sink, 24 VDC• M-2801 8 DO, source, 24 VDC
Power Modules• M-7001 24 VDC, system power• M-7002 5/24/48 VDC, 110/220 VAC, field power• M-7804 8 channels, 0 VDC, field power• M-7805 8 channels, 24 VDC, field power
10
1900020901020
Moxa Inc. [email protected]
Moxa China
Shanghai OfficeTel: +86-21-5258-9955Fax: [email protected]
Beijing OfficeTel: +86-10-6872-3959/60/61Fax: [email protected]
Shenzhen OfficeTel: +86-755-8368-4084/94Fax: [email protected]
Moxa Americas Toll-free: 1-888-MOXA-USA (1-888-669-2872)Tel: +1-714-528-6777Fax: [email protected]
Moxa EuropeTel: +49-89-3 70 03 99-0Fax: +49-89-3 70 03 [email protected]
Moxa Asia-PacificTel: +886-2-8919-1230Fax: [email protected]
www.moxa.com
© 2009 Moxa Inc. All rights reserved.The MOXA logo is a registered trademark of Moxa Inc.All other logos appearing in this document are the intellectual property of the respective company, product, or organization associated with the logo.
Experience the easy-to-use ioLogik now!