SMARTLINE PRESSURE TRANSMITTERPocket Configuration Guide
I Connected IndustriaI
Basic Display Menu
Parameter Applicability Locally WritableLCD Contrast Always YesRotation Time FF Only YesPV Display HART/DE YesPV Decimals HART/DE YesPressure Units HART/DE YesRange/Cal Units FF Only YesZero Correct Always YesLRV Correct HART/DE YesURV Correct HART/DE YesReset Corrects HART/DE YesDAC Zero Trim HART/DE YesDAC Span Trim HART/DE YesLoop Test HART/DE YesLRV Always HART/DEURV Always HART/DEDamping Always HART/DENAMUR HART/DE YesFilter Perf HART Only YesTransfer Func HART/DE DP Only YesFlow Cutoff HART/DE DP Only YesFlow Breakpoint HART/DE DP Only YesTag ID HART/DE YesInstall Date HART/FF 09 HART OnlyFirmware Always YesProtocol Always YesModel Key Always YesExit Menu Always N/A
Parameter Visibility Locally WritableSEL PV (Select Process Variable) Always YesUNITS (Set Pressure Units) Always YesFLUNITS (Set Flow Units) Always YesSCLLOW (Scaling Low) Always used when PV is Flow YesSCLHIG (Scaling High) Always used when PV is Flow YesENTLRV (Enter Lower Range Value ) Always YesENTURV (Enter Upper Range Value) Always YesSETZRO (Zero Correct)* Always YesZEROTR (DAC Zero Trim) When Extended Menu is enabled YesSPANTR (DAC Span Trim) When Extended Menu is enabled YesLPTEST (Loop Test) When Extended Menu is enabled YesSETLRV (Set Lower Range Value) When Extended Menu is enabled YesSET URV (Set Upper Range Value) When Extended Menu is enabled YesCNTRST (Set LCD Contrast) When Extended Menu is enabled YesEXDMENU (Extended Menu)* Always YesEXIT Always N/A* option available in selected ST700 models
Standard Display Menu (HART Only)
Info
rmat
ion
<Return><Return>Firmware Version
Firmware VersionDisplay<Return>
Model KeyElec ModuleFirmware Version
UnitsMeterbodyHART/DE Version
LRLProtocol
URL
<Return>
Tran
smitt
er S
etup
Tag IDUnits<Return>Damping (sec)ParametersNAMUR SelectionEnter LRVFilter Perf.Enter URVTransfer Func.Set LRVFlow CutoffSet URV
<Return>Enter (LRV/URV)<Return>Set (LRV/URV)
Breakpt (%Flow)Install Date
<Return>
Cal
ibra
tion
HourMinuteYearMonthDaySet Time Stamp
<Return>Zero Correct <Return>Trim ZeroLRV Correct Do ( ) CorrectTrim SpanURV CorrectSet DAC NormalReset Corrects <Return>
DAC Trim Set DAC OutputLoop Test Set DAC Normal
<Return>
<Return>
Dis
play
Set
up
LCD Contrast
Screen 1 LanguageScreen 2 Rotation TimeScreen 3Screen 4Screen 5Screen 6Screen 7Screen 8
Common Setup
<Return>
PV SelectionPV ScalingDisplay UnitsCustom UnitsDecimalsDisp Low LimDisp High LimScaling LowScaling HighCustom Tag
Screen FormatTrend Duration<Return>
<Return> Set Contrast
<Return>
Dia
gnos
tics
CriticalNon-Critical
Active Diags<Return>
Analog Out modeZero CorrectSpan CorrectSupply VoltagePrimary PVMeterbody TempElec Module TempMeterbody CommFactory Cal
<Return>Active DiagsMeterbodyElec ModuleMeterbody Comm
<Return>
DAC Temp Comp
Advanced Graphic Display Menu
Honeywell Process Solutions Honeywell
512 Virginia Drive Fort Washington, PA 19034 USA
www.honeywellprocess.com/smartline
34-ST-00-121, Rev.2 December 2016 ©2016 Honeywell International Inc.
Zmenu
Senter
2-button Configuration
Keypad
Advanced Graphic Display Menu
Basic Display Menu
Standard Display Menu
3-button Configuration
Keypad
Zstep up step
down
Senter