SNf\HA
THE SO UTHERN NEVADA REGIONAL HOUSING A UT HO RIT Y 3 40 N 1 1r o
'STR EET LAs VEGAS, NV 89101*3611
This Request for Quale number is Q10073 for the following:
Rehabilitation and Energy Upgrades @ 7136 Nordic Lights Dr., Las Vegas, NV
Neighborhood Stabilization Program (NSP)
Q U OT E F O RMPage 2 of 8
and,D(\l~"O~
*~~~
'('-
~o ~ r"Pc:orrect slope andclearance to drywall
Repairlinstall double wall flue through building cavity, maintain 1" clearance to d~
combustible materialsRepair flue, ensure flue is continuous, proper support and clearances 0Proposed size 60k ~ 1I
Btu healing, 3 ton
COoling.
talinnne
Windows (sq tI)
Install dual glazed low-E/viny/lcomposite windows (U=0.30/SHGC=0.30) or belter
Install window film per HPSFWC 3.1.2
Install solar screens per HPSFWC 3.1.1, fiush mount, 0.20 shading coefficient, brownColor
Remove three arch top windows and infill wall, patch stucco and paint
Mechanical, HVAC & Insulalion
Replace existing rooftop package gas furnace/electric AlC. Install properly sized 80.
AFUE gas furnace, 15 SEER AlC. Provide SUPPorting load cales based on all energyefficiency measures to be installed in home
f '" f'iN ~ I S, \) .; 1 2- 00
Replace existing rooftop package furnace/AC. Inslall properly sized 80. AFUE gas
furnace, provide SUPPorting load cales based on all energy efficiency measures to beinslalled in home
Insulate rooftop plenum with R8 duct wrap.
Seal duct air leakage to 6% CFM25, leakage to outside.
nstall new duct system with optimized design - minimize duct length, configure ducts atoor of attic to be buried in aWe insulation
8/9/2019 SNRHA - 7136 Nordic Lights 89119
4/6
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11'''' STREET. LAs VEGAS, NV 89101-3611
This Request for Quote number is 010073 for the following:
Rehabilitation and Energy Upgrades@ 7136 Nordic Lights Dr .. Las Vegas. NV
Neighborhood Stabilization Program (NSP)
QUOTE FORMPage 4 of8
By licensed Mech.
Eng.
40 gal ... 70 EF min.
R.54 min.
R-30 min.
air seal all kneewalls
HVAC engineering calcuiation: Manual J, D and S (incorporating all installed energy
efficiency measures and final building shell leakage)
Install and program thermostat
Insulate ducts to R-30 by burying all ducts possible in 8" (min) of biown cellulose, use R-8 R-30 min
duct wrap on exposed ducts 1 6 " 1 ~ t - f ! . \lL-~"(L..sMechanical ventilation: use 4" R.8 insulated duct
Vent exhaust fan to outside
Increase attic insulation, provide blown fiberglass
Insulate/air seal frame floor cavity over garage with impermeable spray foam.
Install slab perimeter insulalion. V ~ .fin ~ \; ~ - t+ .Replace water heater, Mfr: AD Smith Eftex
Replace f ireplace insert with new sealed combustion direct vent fireplace insert.
Replace kneewall batt insulation where missing - install air barrier/RoB duct wrap
Lighting
Replace all incandescent light bulbs with compact fluorescent bulbs. Use appropriate
bulb style for fixture (e.g. flame, globe, floodlight) (Install T8 at tube type)
Provide interior light fixtures Bathrooms,
bedrooms
Inslall motion sensors in bathrooms, laundry and pantry to control lighting.
Water
Install low-flow faucet aerators (2.0 gpm kitchen, 1.5 gpm bathroom sinks)
Install low-flow EPA WaterSense approved toilets (1.28 gpf max.)
Install low-flow EPA WaterSense approved shower heads (2.2 gpm max.)
3 toilets
Renewable Energy
Install photovoltaic system
Install solar hot water system
Tolal Energy Efficiency Me ure.
Interior finishes
Repair interior wall and ceiling finishes and paint all interior wall, ceiling and paintable trim
Replace existing countertop with laminate countertop
Repair existing countertop
Repair/replace flooring
Repair/replace sliding accordion door
Repair/replace bath vanity
Install tile flooring, remove existing flooring all bathrooms,laundry and all first
f loor comm on areas
$
$
$
$
$
$
Install new interior window coverings $
8/9/2019 SNRHA - 7136 Nordic Lights 89119
5/6
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N, 11f" STREET. LAS VEGAS. NV 89101-3611
This Request for Quote number is Q10073 for the following
Rehabilitation and Energy Upgrades @ 7136 Nordic Lights Dr., Las Vegas, NV
Neighborhood Stabilization Program (NSP)
QUOTE FORMPage 5 of 8
Repair interior doors
Replace interior doors
Remove cabinet base and upper cabinellhat was added by homeowner. Palch repair,paint drywall to match adjacent wall.
Replace missing bath accessories
Replace cabinets
Repair/replace cover to kitchen light fixture
Landscape
Site
Remove existing treesRemove existing shrubs
Install new Iront yard landscape per WSM
Repair existing irr igation per WSM
Install new irr igation per WSM
Paintlrellis
Remove trellis
Paving
Install drainage block north enclosure waH
Fencing/walls
Check existing irrigation, repair and inst~1lnew if needed to comply with WSM
Remove and cap gas line in backyard.
Electrical
Remove interior surface conduit and f ish replacement wiring through wall
Proper ly run and secure phone/cable TV w ire runs
a
Provide and install new ENERGY STAR dishwasher
Provide and Install new ENERGY STAR refrigerator
Provide and instal! new oven/range
Provide and install new cooktop
Replace ceiling fans with ENERGY STAR model and provide new ENERGY STAR ceilingfans
Install new kitchen exhaust fan and vent to outside with backdraft damper, repair allf inishes to match adjacent.
Provide and install new garbage disposal
Exterior
Repair damaged stucco to match existing texture, patch holes. Paint all exterior buildingsurfaces
Repair damaged fascia
laundry, closet
kitchen, bathroom
$
$
$
$
$
$
8/9/2019 SNRHA - 7136 Nordic Lights 89119
6/6
QUOTE FORMPage 6 of 8
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY 340 N. 11'" STREET. LAS VEGAS, NV 89101.3611
This Request for Quote number is Ql0073 for the followingRehabilitation and Energy Upgrades@ 7136 Nordic Lights Dr" Las Vegas, NV
NeighborhOOd Stabilization Program (NSP)
R e p a ir e x te rio r u t il it y b o x e s to e n s u re w e a th er p ro o f c l o su r e
Seal all outdoor light fixlures to wall, Leave bottom of fixture unsealed
Garage
R e p ai r c o n c r et e s la b
R e p ai r g a r a ge d o o r opener fo r proper opera t ion
Clean garage floor
P r o v id e n e w s c r e e n e d and l o uv e r ed v e n t o p e n in g s
R e p a ir w a l l a n d c e i li n g h o l e s to main lain 1-hour enc losure
Replace allic halChnadder with 1-hour rated hatch
1~5
11 . 5
/6)
IZ,$
$
'P~I'-C-'D A~oV\:..j)t