Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
1 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
COVER SHEET: GENERAL NOTES,LOCATION OF WORK, ENERGY ANALYSIS
A-001.00
09-21-16 LPC FILING
SoHo-Cast Iron
Wes
t Str
eet
East 14th Street
Broa
dway
Eigh
th A
venu
e
Spring St
Broa
dway
Broome St
Grand St
Mer
cer St
Prince St
Cros
by S
t
Mot
t StLa
faye
tte
St
Gre
ene
St
Mul
berr
y St
Woo
ster
St
Canal St
Wes
t Br
oadw
ayTh
omps
on S
t
Sulliva
n StV
aric
k St
Watts St
Eliz
abet
h S
t
W Houston St
Bleecker St
Kenmare St
Howard St
Cent
re S
t
Lispenard St
Walker St
Charlton St
Chur
ch S
t
Vandam St
E Houston St
Cle
vela
nd P
l
St
John's
La
Gre
ene
St E
x
Jersey St
Bond St
Dominick St
White St
Cen
tre
Mar
ket Pl
Jones Al
Av
Of The
Am
eric
as
Av
Of Th
e Am
eric
as
®SoHo-Cast IronHistoric District
ManhattanDesignated: August 14, 1973
Historic District Boundaries
7 301
12
21
12
301
419
53
43
54
434
230
131
130
429
432
80
79
72
17
14060
2601
17617
3
15214
5
16015
9
47983
145142
157162
500499
5453
PLOT MAPSCALE: 1" = 100'
N
PROPERTY INFORMATIONADDRESS:! 62 GREENE STREET, NEW YORK, NY 10012BLOCK:!! 485LOT:! ! 3ZONING MAP:! 12cZONING:! M1-5A!YEAR BUILT:! 1872-73LANDMARK:! SOHO CAST IRON HISTORIC DISTRICT! !
GR
EE
NE
ST
RE
ET
ME
RC
ER
ST
RE
ET
WO
OS
TE
R S
TR
EE
T
BROOME STREET
SPRING STREET
ENERGY CODE TABULAR ANALYSIS:
ITEM DESCRIPTIONPROPOSED DESIGN
VALUECODE PRESCRIPTIVE
VALUE
TO THE BEST OF MY KNOWLEDGE, BELIEF, AND PROFESSIONAL JUDGEMENT, ALL WORK IN THIS APPLICATION ISIN COMPLIANCE WITH THE NYC ENERGY CONSERVATION CODE
SUPPORTINGDOCUMENTATION
ENERGY ANALYSISRESIDENTIAL.REPLACE WINDOWSCLIMATE ZONE: 4PRESCRIPTIVE COMPLIANCE PER NYCECC - TABULAR ANALYSIS
INSTALL NEWWINDOWS PRODUCT DATA SHEETU-FACTOR: 0.55
SHGC: 0.40U-FACTOR: 0.55
SHGC: 0.40
GENERAL NOTES1.! ALL WORK PERFORMED SHALL CONFORM TO THE NEW YORK CITY BUILDING AND
CONSTRUCTION CODE, ADA, OSHA, AND REQUIREMENTS OF ALL OTHER APPLICABLE CODESAND ORDINANCES.
2.! CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD AND SHALLNOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THEWORK.
3.! CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND LICENSES.
4.! CONTRACTOR SHALL KEEP WORK SITE IN NEAT AND ORDERLY CONDITION AND SHALLREMOVE DEBRIS AT THE END OF EACH DAY.
5.! CONTRACTOR SHALL COORDINATE WITH OWNER AND OTHER TRADES FOR ACCESS TOSPACE.
6.! CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER SITE WITH MATERIALS OREQUIPMENT.
7.! CONTRACTOR SHALL NOT LOAD STRUCTURE WITH WEIGHT OF STORED MATERIALS OREQUIPMENT IN EXCESS OF ALLOWABLE FLOOR LOADS.
8.! CONTRACTOR SHALL LOCATE ANY STORED MATERIALS OR EQUIPMENT SO AS NOT TOINTERFERE WITH OPERATION OF RESIDENCE AND/OR OTHER SUBCONTRACTORS.
9.! CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR PROTECTION AND SAFE KEEPINGOF MATERIAL AND EQUIPMENT STORED ON PREMISES.
10.! CONTRACTOR SHALL COORDINATE WITH OWNER FOR ALL PHASES OF WORK AND NOTIFYOWNER AT LEAST 48 HOURS PRIOR TO ANY WORK BEING STARTED.
11.! THE ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADE(S),WHO SHALL ARRANGE FOR AND OBTAIN ALL REQUIRED SIGN-OFFS.
12.! ALL EXISTING ITEMS TO REMAIN AND TO BE REUSED SHALL BE PROTECTED DURING THEPROCESS OF DEMOLITION.
13.! WHERE NEW WORK OCCURS IN AREAS WITH EXISTING FINISHES TO REMAIN, THECONTRACTOR SHALL MATCH EXISTING FINISHES AND MATERIALS UNLESS OTHERWISENOTED OR DIRECTED.
14.! INSPECTIONS: FINAL
TENANT PROTECTION PLAN1.! MEANS OF EGRESS: ALL EXISTING MEANS OF EGRESS FROM THE BUILDING SHALL BE
MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING MATERIALS,TOOLS, ETC.
2.! FIRE SAFETY: THE INTEGRITY OF ALL EXISTING FIREPROOFING SHALL BE MAINTAINED. ALLFLAMMABLE MATERIALS SHALL BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVEMANUFACTURER'S CONTAINERS. SUCH MATERIALS SHALL BE KEPT AWAY FROM HEAT ANDSHALL BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE.
! ALL ELECTRICAL POWER SHALL BE SHUT OFF WHERE THERE IS EXPOSED CONDUIT.
! ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA SHALL BE SHUT OFF AFTERWORKING HOURS.
! THE CONTRACTOR SHALL MAKE SURE THERE IS NO LEAKAGE OF ANY FLAMMABLE GASUSED IN CONSTRUCTION.
! ALL BUILDING MATERIALS STORED AT THE CONSTRUCTION AREA, AND/OR IN ANY AREA OFTHE BUILDING, ARE TO BE SECURED IN A LOCKED AREA. ACCESS TO SUCH AREAS SHALLBE CONTROLLED BY OWNER AND/OR GENERAL CONTRACTOR.
3.! HEALTH REQUIREMENTS: CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTIONOF HEATING, WATER, OR ELECTRICAL SERVICES TO OTHER TENANTS OF THE BUILDINGWITHOUT PRIOR NOTICE. DEBRIS, DUST AND DIRT SHALL BE KEPT TO A MINIMUM AND BECONFINED TO THE IMMEDIATE CONSTRUCTION AREA AND SHALL BE CLEARED FROM THEBUILDING PERIODICALLY TO AVOID EXCESSIVE ACCUMULATION. CONTRACTOR SHALLISOLATE THE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OFTEMPORARY PARTITIONS OR HEAVY DROP CLOTHS.
! ASBESTOS ABATEMENT (IF REQUIRED) SHALL BE IN COMPLIANCE WITH THE LATEST NYCDEPARTMENT OF ENVIRONMENTAL PROTECTION RULES AND REGULATIONS, AND SHALL BEPERFORMED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR.
! LEAD ABATEMENT (IF REQUIRED) SHALL BE IN COMPLIANCE WITH THE U.S.ENVIRONMENTAL PROTECTION AGENCY REGULATIONS, AND SHALL BE PERFORMED BY ACERTIFIED PROFESSIONAL.
4.! STRUCTURAL SAFETY: THE CONTRACTOR SHALL PERFORM ALL WORK (INCLUDINGDEMOLITION AND ERECTION) WITH DUE REGARD TO LIFE AND PROPERTY IN THE VICINITYOF THE WORK AREA. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF SAMEFROM ANY HARM OR DAMAGE DURING THE ENTIRE CONSTRUCTION/AND OR ALTERATION.NO STRUCTURAL WORK SHALL BE DONE THAT MAY ENDANGER THE OCCUPANT'S.
5.! NOISE RESTRICTIONS: CONSTRUCTION OPERATIONS SHALL BE CONFINED TO REGULARWORKING HOURS: MONDAY THROUGH FRIDAY, 8 AM TO 5 P.M., EXCEPT LEGAL HOLIDAYS (NOWORK ON SATURDAYS AND SUNDAYS). ANY WORK WHICH CAN PRODUCE NOISE THAT MAY BEDISTURBING TO BUILDING OCCUPANTS SHALL NOT BE PERFORMED BEFORE 10 A.M.
LIST OF DRAWINGS:A-001.00 ! GENERAL NOTES, LOCATION OF WORK, ENERGY ANALYSIS
A-002.00 ! WEST ELEVATION REPAIRS
A-003.00 ! EAST ELEVATION REPAIRS
A-004.00 ! DETAILS
A-005.00 ! TYPE 1 WINDOW DETAILS
A-006.00 ! TYPE 2 WINDOW DETAILS
A-007.00 ! TYPE 2A WINDOW DETAILS
A-008.00 ! TYPE 2B WINDOW DETAILS
A-009.00 ! TYPE 2C WINDOW DETAILS
A-010.00 ! TYPE 3 WINDOW DETAILS
A-011.00 ! TYPE 4 WINDOW DETAILS
A-012.00 ! TYPE 9 WINDOW DETAILS
A-013.00 ! TYPE 10 WINDOW DETAILS
A-014.00 ! TYPE 11 WINDOW DETAILS
ABBREVIATED SCOPE OF WORK:1. COMPREHENSIVE FACADE AND REAR ELEVATION REPAIR PROGRAM
2. REPAINT ALL METAL RAILINGS AND DUNNAGE ON ROOF
3. CLEANING OF SIDEWALK AND RE-CAULKING OF JOINTS.
4. SCRAPE PRIME AND PAINT EXISTING DIAMOND PLATE AT SIDEWALK LEVEL, TO MATCHEXISTING.
5. WINDOW REPLACEMENT MASTER PLAN
FLOOD INSURANCE RATE MAP (FIRM): PROPERTY IS NOT IN SPECIAL FLOOD HAZARDAREA (SFHA) AS PER MAP NUMBER 3604970182F
WATER TANKBULKHEAD
SKYLIGHT SKYLIGHT
1st FL.SETBACKSKYLIGHT
SKYLIGHT
SKYLIGHT SKYLIGHT
EXH.VENT
SOUTH BULKHEAD
N. ELEVATORBULKHEAD
GR
EEN
E ST
REE
T
SKYL
IGH
T
SLOPESLOPE
VALL
EY
R.D.
MAIN ROOF LEVEL
LEADER
GU
TTER
SLOPE
V.
ALL
EY C
OU
RTY
AR
DS
FIR
E ES
CA
PE
FIR
E ES
CA
PE
REPAINT DUNNAGE REPAINT METALRAILINGS.
REPAINT METALRAILINGS.
REVIEW ALL ROOFS, SEAL ALLOPEN FLASHING MEMBRANESEAMS AS PER ROOFMEMBRANE MANUFACTURER'SREQUIREMENTS.
REPAIR ROOF MEMBRANEAT BULKHEAD DOOR AREA.
SKYL
IGH
T
SCALE: 1/8" = 1' - 0"ROOF PLAN1
A-001
2A-003
2A-002
N
HISTORIC MAPSCALE: N.T.S
62 GREENESTREET
62 GREENE STREET FACADE
62 GREENE REAR ELEVATION
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
2 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
WEST ELEVATION REPAIRS
A-002.00
09-21-16 LPC FILING
SCALE: 3/16" = 1' - 0"
GREENE STREET FACADE EXISTING CONDITIONS1A-002
LOCATIONTYPE
ELEVATORSHAFT1
NOTE: LEAD PAINT ABATEMENT REQUIRED FOR ALL WINDOWS
CONSTRUCTION TYPE
KALAMINE (WOOD, SHEET METALCLAD), DH, 4 OVER 4, SINGLE PANEWIRE GLASS.
WINDOW REPAIRS / REPLACEMENT SCHEDULE:
3
3A2
4
5
CONDITION REPAIR PROGRAM
FRAMES AND SASHES IN VERY POORCONDITION, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
FIRE ESCAPEDOOR
KALAMINE, DOUBLE DOOR, WITHCENTER MUNTIN, SINGLE PANE WIREGLASS. TRANSOM LITE WITH CENTERMUNTIN, SINGLE PANE WIRE GLASS.
EXISTING UNIT IN VERY POORCONDITION, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
LOFT WINDOWS WOOD, DH, 2 OVER 2, SINGLE PANEGLASS.
SASHES HAVE BEEN REFURBISHEDAND ARE IN FAIR CONDITION, NOTCOMPLIANT WITH THE CURRENTENERGY CODE. FRAMES ARE OLD, INPOOR CONDITION.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
LOFT WINDOWS. BLOCKED WINDOW OPENING ORIGINAL WINDOW AS PER #3
LOFT WINDOWS. WOOD, DH, 2 OVER 2, SINGLE PANEGLASS.
VERY POOR, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
STOREFRONTDOORS
FAIR. FRAME, SASH, AND JAMB COMPONENTS, RE-GLAZING OF DOORS ANDTRANSOMS. INSTALL NEW PERIMETER SEALANT AND WEATHER-STRIPPING. VARIOUS OPERABLE DOORFRAME MEMBERS REQUIREREFASTENING OF WOOD JOINTS AND CONNECTIONS AND RESTORATIONOF HARDWARE INCLUDING REALIGNMENT OF HINGES AND DOORCLOSERS. REMOVE PAINT, PRIME, REPAINT ALL WOOD, RE-GLAZE.
DOUBLE DOORS, WITH SINGLE GLASSPANE. TRANSOM LITE, SINGLE PANEGLASS.
6 STOREFRONTFIXED- DOORS
1
1
1
1
2A
2B
2C
3 3 3 3A
3 3
4 4 4
4 4 4 4
6
6 25
2
2A FIRE ESCAPEDOOR
FIRE ESCAPEDOOR
FIRE ESCAPEDOOR
2B
2C
KALAMINE, DOUBLE DOOR, WITHCENTER MUNTIN, SINGLE PANE WIREGLASS. TRANSOM TWO PANES,SINGLE PANE WIRE GLASS.
KALAMINE, DOUBLE DOOR, WITHCENTER MUNTIN, SINGLE PANE WIREGLASS. TRANSOM LITE WITH CENTERMUNTIN, SINGLE PANE WIRE GLASS.
KALAMINE, DOUBLE DOOR, WITHCENTER MUNTIN, SINGLE PANE WIREGLASS. TRANSOM WITH SASHES FORMECHANICAL EQUIPMENT.
EXISTING UNIT IN VERY POORCONDITION, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
EXISTING UNIT IN VERY POORCONDITION, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
EXISTING UNIT IN VERY POORCONDITION, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
3 3
4
NEWELY REPLACEDSTOREFRONT
NORTHERNMOSTSTOREFRONT BAY
FILED AND APPROVEDUNDER SEPARATE PERMIT
(LPC CNE #16-3164)
65 5
FAIR.FIXED DOUBLE DOORS, WITH SINGLEGLASS PANE. TRANSOM LITE, SINGLEPANE GLASS.
3rd FLOOR
4th FLOOR
5th FLOOR
2nd FLOOR
GROUND FLOOR
ROOF
GREENE STREET FACADE - PROPOSED CONDITIONS2A-002 SCALE: 3/16" = 1' - 0"
1
1
1
1
2A
2C
3 3 3
3 3
4 4 4
4 4 4 4
6
6 25
2 3 3
4
65 5
LOCATIONTYPE CONSTRUCTION TYPE CONDITION REPAIR PROGRAM
2B
SCHEDULE CONTINUED:
PLYWOOD
CAST IRON REPAIRS:REMOVE ALL PAINT TO METAL.REPAIR ALL DEFECTIVE PLATESANDORNAMENTATION. OPEN SELECTEDWATERTABLE CAPS, REPAIRARMATURES AS REQUIRED.REPLACE SELECTED WATERTABLEPLATES WHERE DETERIORATEDBEYOND REPAIR. PRIME ANDREPAINT ALL CAST IRON AS PERLPC APPROVED COLOR.SEE DETAIL 7/A-004.
CLEAN PRIME AND PAINTSHEET METAL CORNICE ANDPEDIMENT
REPAIR FIRE ESCAPE:REVIEW ALL CONNECTIONS,REMOVE ALL CORRODEDFASTENERS AND PLATES,REPLACE TO MATCHEXISTING. LIGHTLY SCRAPE,REPAINT ALL STEEL.
EGRESSWINDOWS
5A5A
EGRESSWINDOWS
3A
SCRAPE, CLEAN, PRIME,AND PAINT EXISTINGDIAMOND PLATE TO MATCHEXISTING. CLEAN, ANDRE-CAULK STONE FLAGS.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, SINGLE PANE GLASS. (FROSTED BRONZE GLASSMATCHING SPEC INSTALLED IN #5A UNDER CNE 16-3164)
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
REPLACE WITH NEW WOOD WINDOWS (SASHES AND BRICK MOLDING),DH, 2 OVER 2, INSULATED GLASS TO COMPLY WITH ENERGY CODE.
NEWELY REPLACED STOREFRONTNORTHERNMOST STOREFRONT BAYFILED AND APPROVED UNDERSEPARATE PERMIT.(LPC CNE #16-3164)
5A NEWSTOREFRONTDOOR - FIXED
NEW. NO WORK.
ELEVATOR SHAFTWINDOWS UNITS INFRONT OF EXISTING
ELEVATOR SHAFT WALLINSTALLED UNDER
CNE 88-0880(ISSUED 04-06-1988)
FRAME, SASH, AND JAMB COMPONENTS, RE-GLAZING OF DOORS ANDTRANSOMS. INSTALL NEW PERIMETER SEALANT AND WEATHER-STRIPPING. VARIOUS OPERABLE DOORFRAME MEMBERS REQUIREREFASTENING OF WOOD JOINTS AND CONNECTIONS AND RESTORATIONOF HARDWARE INCLUDING REALIGNMENT OF HINGES AND DOORCLOSERS. REMOVE PAINT, PRIME, REPAINT ALL WOOD, RE-GLAZE.
ELEVATOR SHAFTWINDOWS UNITS INFRONT OF EXISTING
ELEVATOR SHAFT WALLINSTALLED UNDER
CNE 88-0880(ISSUED 04-06-1988)
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
3 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
EAST ELEVATION REPAIRS
A-003.00
09-21-16 LPC FILING
SCALE: 3/16" = 1' - 0"EAST (REAR) ELEVATION - EXISTING CONDITIONS
SETBACKSKYLIGHT
LOCATIONTYPE
EXIT STAIRCASEWINDOWS7
CONSTRUCTION TYPE
REPLACEMENT UNITS. FIREPROTECTED ALUMINUM WINDOWS,DH, 6 OVER 6, INSULATED GLASS.
WINDOW REPAIRS / REPLACEMENT SCHEDULE:
9
8
CONDITION REPAIR PROGRAM
GOOD.
LOFT WINDOWS. REPLACEMENT UNITS, ALUMINUM DH,1 OVER 1, INSULATED GLASS.
LOFT WINDOWS WOOD, DH, 6 OVER 6, SINGLE PANEGLASS.
N/A
GOOD. N/A
VERY POOR, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
REPLACE WITH NEW ALUMINUMWINDOWS, DH, 1 OVER 1, INSULATEDGLASS.
7
7
8 8 8 8 8
9
10B 10 10 10
11 11 11 11
12 12 12 12 12 12
13 13 13 13 14
1A-003
10A 10B
99
1111
9 9
EAST (REAR) ELEVATION - PROPOSED CONDITIONSSCALE: 3/16" = 1' - 0"
3rd FLOOR
4th FLOOR
5th FLOOR
2nd FLOOR
GROUND FLOOR
ROOF
SETBACKSKYLIGHT
BASEMENT
7
7
8 8 8 8 8
12 12 12 12 12 12
13 13 13 13 14
2A-003
10
11
12
LOFT WINDOWS. REPLACEMENT WOOD, DH, 1 OVER 1,SINGLE PANE GLASS. SIZE OF THEWINDOWS VARY.
LOFT WINDOWS. WOOD, DH, 4 OVER 4, SINGLE PANEGLASS.
REAR YARDWINDOWS
REPLACEMENT UNITS, WOOD, SINGLEPANE FIXED WINDOWS, INSULATEDOBSCURED GLASS.ORIGINAL WINDOW CONFIGURATIONNOT KNOWN.
VERY POOR, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.WINDOW OPENINGS ARE PARTIALLYBLOCKED.
REPLACE WITH NEW ALUMINUMWINDOWS, DH, 1 OVER 1, INSULATEDGLASS.
REPLACE WITH NEW ALUMINUMWINDOWS, DH, 1 OVER 1, INSULATEDGLASS. PROVIDE SASH FORMECHANICAL EQUIPMENT.
GOOD. N/A
VERY POOR, NOT COMPLIANT WITHTHE CURRENT ENERGY CODE.
LOCATIONTYPE CONSTRUCTION TYPE CONDITION REPAIR PROGRAM
13 REAR YARDWINDOWS
REPLACEMENT UNITS, WOOD, SINGLEPANE FIXED WINDOWS, AND FIXEDTRANSOM LITE, INSULATEDOBSCURED GLASS.ORIGINAL WINDOWCONFIGURATION NOT KNOWN.
GOOD. N/A
14 REAR YARDDOOR
REPLACEMENT UNIT. WOOD FRAMESINGLE PANE GLAZING. MISSINGTRANSOM WINDOW.
POOR DUE TO DOOR OPENINGCONDITION. DOOR DOES NOTFIT THE OPENING.
REPAIR BRICKWORK AROUND DOOROPENING. INSTALL NEW DOOR ANDTRANSOM LITE TO FIT OPENING.
LOCATIONTYPE CONSTRUCTION TYPE CONDITION REPAIR PROGRAM
10
9
10
9
10
99
11
9
11
SCHEDULE CONTINUED: SCHEDULE CONTINUED:
11 11 11 11
101010
BRICK REPAIRS:POWER WASH 100%.REPOINT 100%.REPLACE CRACKED ANDSPALLED BRICKWORK AS NEEDED,MISCELLANEOUS AREAS.SEE DETAILS 2/A-004, 3/A-004, & 6/A-004.
RESTORE SHUTTERS AND HINGES(3 LOCATIONS).
REPLACE STONE WINDOW LINTELS ANDSILLS WITH PRECAST CONCRETE, TOMATCH STONE IN SIZE, COLOR ANDTEXTURE. EXACT LOCATIONS T..B.D.UPON DETAILED SCAFFOLD REVIEW.SEE DETAILS 1/A-004, 4/A-004, & 5/A-004.
REPAIR BRICK PARTY WALL.
CLEAN PATIO FLOOR, SERVICE DRAINS.
REMOVE PLYWOOD, FILL IN WITHBRICK AS PER SCHEDULE.
REPAIR MASONRY AT OPENINGPERIMETER, REPLACE DOORAS PER SCHEDULE.SEE DETAIL 2/A-004.
REMOVE ABANDONEDMECHANICAL EQUIPMENT
REPAIR BRICK MASONRY ASNEEDED. SPOT REPOINT,CLEAN.SEE DETAILS 2/A-004, & 3/A-004.
REPAIR FIRE ESCAPE: REVIEWALL CONNECTIONS, REMOVEALL CORRODED FASTENERSAND PLATES, REPLACE TOMATCH EXISTING. LIGHTLYSCRAPE, REPAINT ALL STEEL.
NON-VISIBLE REAR ELEVATION(SEE PARTIAL SECTION 3/A-003
AT REAR YARD)
EXISTING SPANDRELSHEET METAL CLADDING(NO WORK - GOOD CONDITION)
EXISTING SPANDRELSHEET METAL CLADDINGINSTALLED UNDER CNE 09-2517ISSUED IN 2008
15 REAR YARDSET-BACKSKYLIGHT
METAL AND GLASS SKYLIGHTINSTALLED UNDER CNE 09-2517ISSUED IN 2008
1515
GOOD. N/A
8'
23'-9"
3rdFLOOR
4thFLOOR
5thFLOOR
2ndFLOOR
GROUNDFLOOR
ROOF
BASEMENT
3rdFLOOR
4thFLOOR
5thFLOOR
2ndFLOOR
GROUNDFLOOR
ROOF
BASEMENT
6thFLOOR
PL
62 GREENE ST.5 STORIES
77 MERCER ST.6 STORIES
REAR YARD& ELEVATIONNOT VISIBLE
FROM STREETPUBLIC
WAY
PL
SCALE: 1/16" = 1' - 0"3
A-003
PARTIAL SECTION @ REAR YARD OF62 GREENE ST. & 77 MERCER ST.
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
4 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
FACADE REPAIR DETAILS
A-004.00
09-21-16 LPC FILING
2a
a
SCALE: 3" - 1'0"
EXISTING MASONRYTO REMAIN.
INSTALL WEEP HOLES @EVERY 16" O.C. OR AT EA.JOINT.
EXISTING WINDOW TO REMAIN.
REPLACE PERIMETER SEALANT.SUBMIT COLOR SAMPLE FORARCHITECTS APPROVAL.
RECONSTRUCT ALLDAMAGED BRICK @ SILLREPLACEMENT WORKAREAS AS NEEDED.
REPLACE EXISTING STONE SILLW/ NEW CAST STONE TOMATCH SIZE, COLOR &TEXTURE OF EXISTING STONE.FASTEN TO MASONRY W/ 1/2"DIA S.S. THREADED PINS - MINTWO PER UNIT. SET INTO PRE-DRILLED HOLES FILLED W/EPOXY.
STONE WINDOW SILL REPLACEMENT
INSTALL NEW BACKER ROD AND SEALANT.
RECONSTRUCT FACEBRICK; INSTALL S.S. 12GA. CORRUGATED BUCK ANCHOR S.S. WALLTIES @ EVERY THREE BRICK COURSES AND16" O.C. HORIZONTALLY. NEW BRICK SIZE,COLOR AND BOND TO MATCH EXISTING.
INSTALL WEEP TUBES @ EVERY 16" O.C.
CLEAN SUBSTRATE; INSTALLPERM-A-BARRIER FLASHING MEMBRANE.PRIME SUBSTRATE AS REQUIRED. FORM ENDDAMS. FASTEN WITH S.S. TERMINATION BAR,SEAL AT PENETRATIONS WITH MASTIC.
REMOVE EXISTING STONE LINTEL , EVALUATECONDITION, SAVE FOR REINSTALLATION.REPLACE WTH MATCHING CAST STONE LINTEL IFSTONE IS DETERIORATED BEYOND REPAIR.REPAIR SURROUNDING BRICKWORK, RESETLINTEL, FASTEN W / 3/8" DIA MIN. S.S. ANCHORS(MIN. FOUR PER UNIT). SET INTO EPOXY. EXACTFASTENING T.B.D. UPON FIELD CONDITIONS. SUBSTRATE TO
BE VERIFIED INFIELD.
STONE WINDOW LINTEL REPAIR
INSTALL 7oz. COPPER FABRICTHRU-WALL FLASHING. TURN UPAT TERMINATIONS. FASTEN ATBACK WITH S.S. TERMINATION BAR,SEAL AT ALL JOINTS ANDPENETRATIONS AS REQUIRED.INSTALL WEEP HOLES AT EACHJOINT.
4A-004
SCALE: 3"=1'-0"
EXISTING BACK-UP MASONRY
REMOVE EXISTING DAMAGED FACEBRICKAND LOOSE BACK-UP MASONRY. FILL ALLVOIDS W/ MORTAR AS REQUIRED.RECONSTRUCT FACEBRICK TO MATCHEXISTING IN SIZE, COLOR, FINISH, ANDBOND.
INSTALL #345 S.S. CORRUGATED BUCKANCHOR BY HOHMANN & BARNARD@EVERY 3rd BRICK COURSE & EVERY 16"O.C. HORIZONTALLY.
TYPICAL FACEBRICK RECONSTRUCTION(W/ TRUE HEADERS)SCALE: 3" = 1'-0"
REMOVE EXISTING DAMAGED FACEBRICKAND LOOSE BACK-UP MASONRY. FILL ALLVOIDS W/ MORTAR AS REQUIRED.RECONSTRUCT FACEBRICK TO MATCHEXISTING IN SIZE, COLOR, FINISH, ANDBOND.
INSTALL #345 12 GA. S.S. CORRUGATEDBUCK ANCHOR BY HOHMANN & BARNARD@ EVERY 6th BRICK COURSE & EVERY 16"O.C. HORIZONTALLY.
EXISTING BACK-UP MASONRY
RESTORE TRUE-HEADERS
TYPICAL FACEBRICK RECONSTRUCTIONSCALE: 3" = 1'-0"
2A-004
NOTE: JOINT PROFILE TO MATCHORIGINAL AS PER FIELDCONDITIONS AND AS PERARCHITECT APPROVED SAMPLE.
REMOVE OLD DETERIORATEDMORTAR. REPOINT JOINTS TOMATCH ORIGINAL MORTAR.
CREATE A MECHANICAL KEY BYUNDERCUTTING EDGE AND DRILLINGHOLES.
PREPARE STONE SURFACE AND APPLYMIX AS PER PATCHING MANUFACTURER'SREQUIREMENTS: CLEAN SURFACE OFDUST, PRIME. FILL CAVITY WITH LAYEREDPATCHING MORTAR. SCRATCH EACHLAYER OF MORTAR AND TOOL SURFACEOF FINAL LAYER TO MATCH STONE.
N.T.S.MASONRY REPOINTING DETAIL
N.T.S.STONE PATCHING
CUT SQUARE ON EDGES (NOFEATHERING PERMITTED).
5A-004
6A-004
1A-004
3A-004
REPAIR / REPLACE WINDOW / DOOR TOMATCH ORIGINAL. FOR WINDOW REPAIRSCHEDULE SEE ELEVATION DRAWING 1/2
EXISTING FLOORASSEMBLY
INTERIORFINISHED FLOOR
EXISTING WALLFURRING, NO WORK
EXISTING CAST IRONCOLUMN. NO WORK.
RESTORE EXISTING CAST IRON:REMOVE ALL PAINT, REPAIR ALLCRACKED PLATES, REVIEW ALLFASTENERS & INSTALL NEW WHEREMISSING OR DETERIORATED (FLATHEAD S.S.SCREWS, DIA. TO MATCHEXISTING). INSTALL IRON PLATES ATAREAS WHERE EXISTING CAST IRONIS DETERIORATED BEYOND REPAIR.NEW IRONWORK TO MATCH ORIGINAL.PAINT ALL CAST IRON AS REQ'D. SEESPEC'S FOR CAST IRON REPAIRALLOWANCES.
REPLACE SILL TOP PLATE W/ NEW BENTSTEEL PLATE TO REPLICATE ORIGINALSET TO SLOPE. ALL LOCATIONS 2nd - 5thFLOOR.
REPAIR OR REPLACE VERTICALSILL PLATE, SEE SPECS FORALLOWANCES. REFASTEN ASREQUIRED.
INSTALL NEW CONTINUOUSSTEEL L 4"x4"x3/8": FASTENTO COLUMN
INSTALL NEW CONTINUOUS STEELL 6"x6"x1/2": FASTEN TO COLUMN.
INSTALL NEW STEEL BRACKET L 4"x4"x3/8"@ EVERY 24" O.C.
REPAIR EXISTING CAST IRON ORREPLACE WATERTABLE TOP PLATEW/ NEW BENT STEEL PLATES TOREPLICATE ORIGINAL FROM 2nd -5th FLOOR. SEE SPECS FORALLOWANCES.
REPAIR ALL EXISTINGWATERTABLE & SILL ARMATURES.INSTALL NEW STEEL STRAPSAND SUPPORTING ARMATURESAS INDICATED, PAINT ALL NEWSTEEL AS REQ'D. FINAL NEWARMATURE CONFIGURATION TOBE CONFIRMED UPON FIELDCONDITIONS. REMOVE ALLLOOSE MATERIALS FROM INSIDEWATERTABLE AT WORK AREA.
INSTALL NEW 3/8"x 2" BENTSTEEL STRAP @ EVERY 24"O.C.
ALTERNATE
ALTERNATE
SCALE: 3" = 1'-0"WATER TABLE REPAIRS (TYP.)7
A-004
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
5 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 1 WINDOW DETAILS
A-005.00
09-21-16 LPC FILING
4"
0 1/2" 2 3/4" 0 3/4" 3"
0 3/4"0 1/4"
1"
0 1/2"
3"
1 1/2"
3"
0 1/2"
3 1/4"
0 1/2"
0 1/2"
3 1/4"
0 1/2"
0 1/2"
3 1/4"
0 1/2"
1 3/4"
0 1/2"
2"
0 1/2"
1"
1 3/4"
0 1/2"0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
MEETINGRAIL
HEAD
3 WINDOW TYPE 1 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 1 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
4 WINDOW TYPE 1 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 1 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
MUNTIN
SILL
MUNTIN
INTERIOR
HEAD
MEETINGRAIL
SILL
ELEVATORSHAFT
ELEVATORSHAFT
ELEVATORSHAFT
EXISTING ELEVATORSHAFT WALL
FROSTED BRONZE GLASS FROSTED BRONZE GLASS
ELEVATORSHAFT
EXISTING ELEVATORSHAFT WALL
5'-3 1/4"
5'-8 1/4"
8'-3
3/4
"8'
-1 1
/4"
4'-3
1/2
"
5'-3 1/4"
5'-8 1/4"
7'-1
1 1/
2"
4'-5
1/2
"
8'-3
3/4
"
1 EXISTING WINDOW TYPE 1SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 1
SCALE: 1/2" = 1'-0"
5
3
6
4
EXISTING WINDOW TYPE 1
EXISTING WINDOW TYPE 1
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
6 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 2 WINDOW DETAILS
A-006.00
09-21-16 LPC FILING
0 1/2"
6 3/4"
0 1/2"
0 1/2"
2 1/2"
0 1/2"
1 3/4"
0 1/2"
3 3/4"
0 1/2"
0 1/2"
6 1/2"
1 1/2"
3"
0 1/2" 3 1/2" 0 3/4" 3"
4 3/4"
0 3/4"0 1/4"
1"
1"
1 3/4"
0 1/2"
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
INTERIORHEAD
MEETINGRAIL
SILL
MUNTIN
4 WINDOW TYPE 2 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"3 WINDOW TYPE 2 EXISTING - JAMB PLAN
SCALE: 3" = 1'-0"
5 WINDOW TYPE 2 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0" 6 WINDOW TYPE 2 PROPOSED - WINDOW SECTION AND JAMB DETAIL
SCALE: 3" = 1'-0"
INTERIOR INTERIOR
INTERIOR
HEAD
MEETINGRAIL
SILL
5'-3 1/4"
5'-8 1/4"
6'-9
"
8'-9
1/4
"
8'-1
1 1/
2"
5'-3 1/4"
5'-8 1/4"
8'-1
1 1/
2"8'
-9 1
/4"
1 EXISTING WINDOW TYPE 2SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 2
SCALE: 1/2" = 1'-0"
5
3
4
6
EXISTING WINDOW TYPE 2 EXISTING WINDOW TYPE 2
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
7 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 2A WINDOW DETAILS
A-007.00
09-21-16 LPC FILING
0 1/2"
9 3/4"
0 1/2"
0 1/2"
5 3/4"
0 1/2"
1 3/4"
0 1/2"
5 1/2"
0 1/2"
0 1/2"1 1/4"
1 1/2"
3"
0 1/2"
1 3/4"
0 1/2"
0 3/4"0 1/4"
1"
1"
1 3/4"
0 1/2"
0 1/2" 4 3/4" 0 3/4" 3"
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
4 WINDOW TYPE 2A PROPOSED - JAMB PLANSCALE: 3" = 1'-0"3 WINDOW TYPE 2A EXISTING - JAMB PLAN
SCALE: 3" = 1'-0"
5 WINDOW TYPE 2A EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0" 6 WINDOW TYPE 2A PROPOSED - WINDOW SECTION AND JAMB DETAIL
SCALE: 3" = 1'-0"
INTERIOR
HEAD
MEETINGRAIL
SILL
MUNTIN
INTERIOR INTERIOR
HEAD
MEETINGRAIL
SILL
INTERIOR
8'-6
1/2
"
8'-9
"
6'-3
"
5'-3 1/4"5'-8 1/4"
5'-3 1/4"
5'-8 1/4"
8'-9
"8'
-6 1
/2"
1 EXISTING WINDOW TYPE 2ASCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 2A
SCALE: 1/2" = 1'-0"
5
3
4
6
EXISTING WINDOW TYPE 2A
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
8 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 2B WINDOW DETAILS
A-008.00
09-21-16 LPC FILING
0 1/2"
4"
0 1/2"
0 1/2"
2 1/4"
0 1/2"
1 3/4"
0 1/2"
3 3/4"
0 1/2"
0 1/2"
3"
1 1/2"
3"
0 3/4"0 1/4"
1"
1"
1 3/4"
0 1/2"
0 1/2" 2 3/4" 0 3/4" 3"
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
4 WINDOW TYPE 2B PROPOSED - JAMB PLANSCALE: 3" = 1'-0"3 WINDOW TYPE 2B EXISTING - JAMB PLAN
SCALE: 3" = 1'-0"
5 WINDOW TYPE 2B EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0" 6 WINDOW TYPE 2B PROPOSED - WINDOW SECTION AND JAMB DETAIL
SCALE: 3" = 1'-0"
INTERIOR
HEAD
MEETINGRAIL
SILL
MUNTIN
INTERIOR
INTERIOR
HEAD
MEETINGRAIL
SILL
INTERIOR
INTERIOR
6'-7
"
9'-3
"
9'-5
1/4
"
5'-3 1/4"5'-8 1/4"
5'-3 1/4"5'-8 1/4"
9'-5
1/4
"9'
-3"
1 EXISTING WINDOW TYPE 2BSCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 2B
SCALE: 1/2" = 1'-0"
5
3 4
6
EXISTING WINDOW TYPE 2B
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
9 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 2C WINDOW DETAILS
A-009.00
09-21-16 LPC FILING
0 1/2"
3"
0 1/2"
1 3/4"
0 1/2"
2 1/4"
0 1/2"
0 1/2"
3 1/4"
1 1/2"
3"
0 3/4"0 1/4"
1"
1"
1 3/4"
0 1/2"
0 1/2" 6 1/4" 0 3/4" 3"
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
INTERIOR
INTERIOR
3 WINDOW TYPE 2C EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 2C EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
4 WINDOW TYPE 2C PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 2C PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
HEAD
SILL
MUNTIN
INTERIOR
INTERIOR
HEAD
MEETINGRAIL
SILL
8'-1
0 3/
4"
9'-1
1/4
"
6'-7
"
5'-3 1/4"5'-8 1/4"
5'-3 1/4"5'-8 1/4"
9'-1
1/4
"8'
-10
3/4"
1 EXISTING WINDOW TYPE 2CSCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 2C
SCALE: 1/2" = 1'-0"
5
3 4
6
EXISTING WINDOW TYPE 2C
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
10 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 3 WINDOW DETAILS
A-010.00
09-21-16 LPC FILING
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
4"
1/2" 2 3/4" 3/4" 3"
0 3/4"0 1/4"
1"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
1"
1 3/4"
0 1/2"
1"
1 3/4"
0 1/2"
4"
3 WINDOW TYPE 3 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 3 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
4 WINDOW TYPE 3 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 3 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
HEAD
MEETINGRAIL
SILL
HEAD
MEETINGRAIL
SILL
5'-3 1/4"
5'-8 1/4"
7'-1
1 1/
2"
4'-5
1/2
"
8'-3
3/4
"
5'-3 1/4"
5'-8 1/4"
7'-1
1 1/
2"
4'-5
1/2
"
8'-3
3/4
"
1 EXISTING WINDOW TYPE 3SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 3
SCALE: 1/2" = 1'-0"
5 6
43
EXISTING WINDOW TYPE 3
EXISTING WINDOW TYPE 3
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
11 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 4 WINDOW DETAILS
A-011.00
09-21-16 LPC FILING
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
0 3/4"0 1/4"
1"
1/4"1/2"
3/4"3"
1"
1 3/4"
0 1/2"
0 1/4"2 1/4"
0 1/4"
1 3/4"
0 1/2"
3 3/4"
0 1/4"
0 1/4"
3"
1 1/2"
3"
0 3/4"0 3/4"0 1/2"
1/2" 2 3/4" 3/4" 3"
1"
1 3/4"
0 1/2"
4"
3 WINDOW TYPE 4 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 4 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
4 WINDOW TYPE 4 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
INTERIOR
INTERIOR
HEAD
MEETINGRAIL
SILL
HEAD
MEETINGRAIL
SILL
6 WINDOW TYPE 4 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
INTERIOR
8'-3
3/4
"
7'-1
1 3/
4"
5'-3 1/4"
5'-8 1/4"
7'-1
1 3/
4"
8'-3
3/4
"
4'-3
1/4
"
1 EXISTING WINDOW TYPE 4SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 4
SCALE: 1/2" = 1'-0"
5 6
43
EXISTING WINDOW TYPE 4
EXISTING WINDOW TYPE 4
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
12 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 9 WINDOW DETAILS
A-012.00
09-21-16 LPC FILING
1 1/4"0 1/2"
3 3/4"
0 1/4"
0 1/4"1 3/4"
0 1/4"
1 3/4"
1 3/4"
2 3/4"
1 3/4"
0 1/2"
2 3/4"
2 1/4"0 3/4"
2 1/2"4"1"0 1/4"
0 1/2"0 3/4"0 1/2"
0 3/4"0 1/4"
1"
1"
1 3/4"
0 1/2" 0 1/2"0 3/4"0 1/2"
HEAD
MEETINGRAIL
SILL
MUNTIN
3 WINDOW TYPE 9 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 9 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
4 WINDOW TYPE 9 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 9 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
HEAD
SILL
INTERIOR
INTERIORMEATING
RAIL INTERIOR
MUNTIN
9'-2
"
8'-8
1/2
"
4'
4'-4"
4'-8
1/4
"
4'-6
"
9'-2
"
4'
4'-4"
8'-8
1/4
"
1 EXISTING WINDOW TYPE 9SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 9
SCALE: 1/2" = 1'-0"
5
3 4
6
EXISTING WINDOW TYPE 9
EXISTING WINDOW TYPE 9
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
13 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 10 WINDOW DETAILS
A-013.00
09-21-16 LPC FILING
0 1/4"2 1/4"
0 1/4"
1 1/4"
0 1/2"
3 3/4"
0 1/4"
2 3/4"
2 1/4"0 3/4"
2 1/2"4"0 1/4"
0 1/2"0 3/4"0 1/2"
0 3/4"0 1/4"
1"
0 1/4"
3"
0 3/4"
1 3/4"
1 3/4"
1 3/4"
0 1/2"
2 3/4"
1"
1 3/4"
0 1/2" 0 1/2"0 3/4"0 1/2"
SILL
INTERIOR
3 WINDOW TYPE 10 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 10 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
4 WINDOW TYPE 10 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 10 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
MEETINGRAIL
HEAD
MEATINGRAIL INTERIOR
INTERIORINTERIOR
HEAD
SILL
4'-1"
4'-4"
8'-1
1/2
"
7'-5
1/4
"
4'-2
1/4
"
4'-6
"
9'-2
"
4'
4'-4"
8'-8
1/4
"
1 EXISTING WINDOW TYPE 10SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 10
SCALE: 1/2" = 1'-0"
5
34
6
EXISTING WINDOW TYPE 10
DATE
SCALE DRAWN BY
DRAWING TITLE
PROJECT NAME
TEL: 2 1 2 - 2 1 9 -1 0 3 8 FAX: 2 1 2 - 2 2 6 - 8 0 5 6561 BROADWAY, No. 8D NEW YORK, NY 10012
AS INDICATED
REVISIONS
1
2
3
4
5
6
7
8
9
10
11
BONE / LEVINE ARCHITECTSARCHITECT:
SEAL & SIGNATURE:
PAGE:
ZD/BK/PR/GL
62 GREENE STREETFACADE REPAIR PROGRAM AND
WINDOW REPLACEMENT MASTER PLAN
NYC DOB PLAN ID NUMBER:
© C O P Y R I G H T B O N E / L E V I N E A R C H I T E C T S 2 0 1 6
14 of 14
09-21-16
08-12-16 LPC CONCEPT REVIEW
TYPE 11 WINDOW DETAILS
A-014.00
09-21-16 LPC FILING
0 3/4"
2 1/4"
2 3/4"
1 3/4"
0 1/2"
2 3/4"
2 1/4"0 3/4"
2 1/2"
0 1/4"1 1/4"
0 1/4"
0 1/4"0 3/4"0 1/4"
0 1/4"0 3/4"0 1/4"
1 1/4"0 1/2"
1"
0 1/4"
0 1/4"
2 1/4"
0 3/4"
2 1/4"1 3/4"
1"
0 3/4"0 1/4"
1"
0 1/2"0 3/4"0 1/2"
1"
1 3/4"
0 1/2" 0 1/2"0 3/4"0 1/2"
MUNTIN
3 WINDOW TYPE 11 EXISTING - JAMB PLANSCALE: 3" = 1'-0"
5 WINDOW TYPE 11 EXISTING - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
4 WINDOW TYPE 11 PROPOSED - JAMB PLANSCALE: 3" = 1'-0"
6 WINDOW TYPE 11 PROPOSED - WINDOW SECTION AND JAMB DETAILSCALE: 3" = 1'-0"
INTERIOR
INTERIOR
HEAD
SILL
MEATINGRAIL INTERIOR
INTERIOR
MEETING RAIL
MUNTIN
SILL
HEAD
4'-4"
4'-1"
9'-2
"
8'-1
0"
4'-5
1/4
"
4'-6
"
9'-2
"
4'
4'-4"
8'-8
1/4
"
1 EXISTING WINDOW TYPE 11SCALE: 1/2" = 1'-0" 2 PROPOSED WINDOW TYPE 11
SCALE: 1/2" = 1'-0"
5
3 4
6
EXISTING WINDOW TYPE 11
EXISTING WINDOW TYPE 11EXISTING WINDOW TYPE 11