SHEET: TITLE: CLIENT: PV-1 REVISIONS: DATE: DESIGN BY: JOB NO.: SYSTEM SUMMARY, NIOTES, SITE LOCATION AND HOUSE AERIAL VIEW DESCRIPTION DATE REVISION PHOTOVOLTAIC SYSTEM PV SYSTEM SUMMARY: CITY NOTES: ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE : STC: 36 X 265 = 9540W DC PTC: 36 X 235.6 = 8481.6W DC MODULE : 36 X SUNMODULE, SW 265 MONO BLACK, 265W MODULES INVERTER : 1 X SMA SB 5000TL-US-22 & 1 X SMA SB 3000TL-US-22 INVERTERS ROOF : COMP TILE ROOF TILT : R1 & R2 - 5 PITCH AZIMUTH : R1 - 270 & R2 - 90 RAFTER/TRUSS SIZE : 2" X 4" RAFTERS @ 24" O.C ATTACHMENT TYPE : QUICK MOUNT ATTACHMENTS UTILITY : SOUTHERN CALIFORNIA EDISON (SCE) SITE LOCATION: HOUSE AERIAL VIEW: 12/22/2015 XXX BAC-XXX XXX XXXX 1111, XXX STREET XXXXX, CA XXXX Tel: (xxx) xxx xxxx SITE LOCATION ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. THIS PROJECT COMPLIES WITH THE FOLLOWING: 2013 CALIFORNIA BUILDING CODE (CBC) / 2013 INTERNATIONAL BUILDING CODE (IBC) 2013 CALIFORNIA ELECTRICAL CODE (CEC) / 2013 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF ONTARIO INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. TABLE OF CONTENTS PV-1 SYSTEM SUMMARY, NOTES, SITE LOCATION AND HOUSE AERIAL VIEW PV-2 SITE PLAN / ROOF PLAN WITH MODULES LAYOUT PV-3 DETAILS, MATERIAL LIST AND LABELS PV-4 ELECTRICAL CALCULATION, EQUIP. ELEVATION & SINGLE LINE DIAGRAM PV-5 DATA SHEET: MODULE AND INVERTER PV-6 DATA SHEET: MOUNT & RAIL

Solar Power Design Documents

Embed Size (px)

DESCRIPTION

This is a set of documents that guide technicians who install solar photovoltaic panels on residential rooftops. TMG generates these documents on the request of solar power contractors, EPCs, developers and construction companies.

Citation preview

  • SHEET:TITLE:CLIENT:

    PV-1

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    SYSTEM SUMMARY,NIOTES, SITELOCATION ANDHOUSE AERIAL VIEW

    DESCRIPTION DATE REVISION

    PHOTOVOLTAIC SYSTEMPV SYSTEM SUMMARY: CITY NOTES:

    ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM

    SYSTEM SIZE : STC: 36 X 265 = 9540W DC

    PTC: 36 X 235.6 = 8481.6W DC

    MODULE : 36 X SUNMODULE, SW 265 MONO BLACK, 265WMODULES

    INVERTER : 1 X SMA SB 5000TL-US-22 & 1 X SMA SB 3000TL-US-22INVERTERS

    ROOF : COMP TILE ROOF

    TILT : R1 & R2 - 5 PITCH

    AZIMUTH : R1 - 270 & R2 - 90

    RAFTER/TRUSS SIZE : 2" X 4" RAFTERS @ 24" O.C

    ATTACHMENT TYPE : QUICK MOUNT ATTACHMENTS

    UTILITY : SOUTHERN CALIFORNIA EDISON (SCE)

    SITE LOCATION:

    HOUSE AERIAL VIEW:

    12/22/2015

    XXX

    BAC-XXX

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx

    SITE LOCATION

    ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THEMAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILARTO THE SURFACE UPON WHICH THEY ARE MOUNTED

    VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSEDELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BECOLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME.

    THIS PROJECT COMPLIES WITH THE FOLLOWING:2013 CALIFORNIA BUILDING CODE (CBC) / 2013 INTERNATIONAL BUILDING CODE (IBC)2013 CALIFORNIA ELECTRICAL CODE (CEC) / 2013 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY CITY OF ONTARIO

    INSTALLATION NOTES:THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAINSERVICE BUSS RATING.PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESSINVERTERS.INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK.

    TABLE OF CONTENTSPV-1 SYSTEM SUMMARY, NOTES, SITE LOCATION ANDHOUSE AERIAL VIEW

    PV-2 SITE PLAN / ROOF PLAN WITH MODULES LAYOUT

    PV-3 DETAILS, MATERIAL LIST AND LABELS

    PV-4 ELECTRICAL CALCULATION, EQUIP. ELEVATION &SINGLE LINE DIAGRAM

    PV-5 DATA SHEET: MODULE AND INVERTER

    PV-6 DATA SHEET: MOUNT & RAIL

  • MSP

    MSP

    ACD

    FMLC

    INV1

    INV2

    JB

    JB

    SHEET:TITLE:

    PV-2

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    SITE PLAN / ROOF PLANWITH MODULES LAYOUT

    DESCRIPTION DATE REVISION

    ROOF PLAN WITH MODULES LAYOUTSCALE: 3/32" = 1'-0" 2SITE PLANSCALE: 1/16" = 1'-0" 1

    EXISTING MSPAC DISCONNECTFINANCE METER

    EXTERNAL CONDUIT RUN

    ROOF AREA STATEMENT

    ROOF MODULESQTY PITCH AZIMTUH ROOF AREA ARRAY AREA

    1 24 5 270 818.87 SQ FT 421.53 SQ FT2 12 5 90 644.48 SQ FT 211.97 SQ FT

    W 4TH ST

    DRIVE WAY

    EXISTINGMSP

    PROPERTY LINE

    SMA SB 5000TL-USINVERTER

    24 SUNMODULE SW 265MONO BLACK MODULES

    ATTACHMENT POINTS@ 48" O.C. MAX (TYP)

    12 SUNMODULE SW 265MONO BLACK MODULES

    PROPOSED MODULES

    ROOF LINE

    JUNCTION BOX

    LOAD CENTER

    12/22/2015

    XXX

    BAC-XXX

    24 SUNMODULE SW 265MONO BLACK MODULES

    ATTACHMENT POINTS@ 48" O.C. MAX (TYP)

    12 SUNMODULE SW 265MONO BLACK MODULES

    3'-3"

    3'

    17'-10"

    R-1

    R-2

    JUNCTION BOX

    SMA SB 3000TL-USINVERTER

    3'

    3'

    11'-8"

    CLIENT:

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx

  • SHEET:TITLE:

    PV-3

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    DETAILS, MATERIALLIST AND LABELS

    DESCRIPTION DATE REVISION

    MATERIAL LIST

    QTY EQUIPMENT DESCRIPTION

    36

    SUNMODULESW 265 MONOBLACK, SOLAR

    MODULES

    OPEN CIRCUIT VOLTAGE (Voc) :MAX. POWER VOLTAGE (Vmp) :

    SHORT CIRCUIT CURRENT (Isc) :MAX. POWER CURRENT (Imp) :

    PTC RATING :

    39.0V30.8V9.31A8.69A235.6V

    1

    SMA, SB5000TL-US-22

    INVERTER WITHINTEGRATEDDISCONNECT

    MAX. DC INPUT VOLTAGE :MAX. DC INPUT CURRENT :

    MAX. AC OUTPUT VOLTAGE RANGE :MAX. AC OUTPUT CURRENT :

    MAX. AC POWER OUPUT :CEC EFFICIENCY :

    600V15A211-264V22A5000W96.5%

    1

    SMA, SB3000TL-US-22

    INVERTER WITHINTEGRATEDDISCONNECT

    MAX. DC INPUT VOLTAGE :MAX. DC INPUT CURRENT :

    MAX. AC OUTPUT VOLTAGE RANGE :MAX. AC OUTPUT CURRENT :

    MAX. AC POWER OUPUT :CEC EFFICIENCY :

    600V15A211-264V15A3000W96%

    2 JUNCTION BOX 600VDC, NEMA 4X, UL LISTED

    1 ACDISCONNECT 600VAC, 60A, NEMA 3R, UL LISTED

    1 LOAD CENTER 240VAC, 125A UL LISTED

    1 PV BREAKER 2 POLE, 240V, 40A

    1 METER LGATE 101 CPF METER

    70' CONDUIT 3/4" EMT CONDUIT

    66 ATTACHMENTS QUICKMOUNTATTACHMENTS

    200' RAIL UNIRAC

    64 MID CLAMPS

    16 END CLAMPS

    LABELS

    W 4TH ST

    LABEL: MAIN SERVICE PANEL

    12/22/2015

    XXX

    BAC-XXX

    ENLARGED DETAIL 2

    ATTACHMENT DETAIL 1

    PV MODULE

    QUICK MOUNTATTACHMENTS

    "L" BRACKETMODULE

    MOUNTINGRAIL

    SS LAG BOLT

    2" X 6" RAFTERS @ 24" O.C

    PV MODULE

    MODULEMOUNTING RAIL

    "L" BRACKET

    SS LAG BOLT

    QUICK MOUNTATTACHMENTS

    2

    PV-4

    ROOF

    4"

    LABEL: MAIN SERVICE PANEL EXISTINGSUBPANEL, AND EXISTING EQUIPMENT TIED INTO.

    LABEL: INSTALLED SUBPANELS AND FUSEBOXES.

    LABEL: INSTALLED JUNCTION BOXES,COMBINER BOXES AND GUTTER BOXES.

    LABEL: AC, DC DISCONNECT OROTHER DISCONNECTING MEANS.

    LABEL: INSTALLED INVERTER

    LABEL: INSTALLED JUNCTION BOXES,COMBINER BOXES AND GUTTER BOXES.

    LABEL: INSTALLED DC JUNCTION BOX

    LABEL: INSTALLED AC AND DC DISCONNECTS

    ALL PLACARDS SHOULD BE WITH WHITE LETTERING IN RED BACKROUND WITH A MIN. OF 3/8"LETTERING HEIGHT AND USING ARIAL OR SIMILAR FONT, NON-BOLD AND ALL CAPITAL LETTERS

    CLIENT:

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx

  • SHEET:TITLE:

    PV-4

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    ELECTRICALCALCULATION, EQUIP.ELEVATION & SINGLELINE DIAGRAM

    DESCRIPTION DATE REVISION

    SINGLE LINE DIAGRAMSCALE: NTS 1

    ELECTRICAL CALCULATIONS:STRING 1 CIRCUIT CURRENT CALCULATION:2 X 12 SUNMODULE 265W MODULESCONNECTED TO 1 SMA 5000TL kW INVERTER

    MAX. INVERTER OUTPUT POWER: 5000WNOMINAL VOLATGE: 240VRATED OUTPUT CURRENT: 22 AMPS

    OVERCURRENT PROTECTION22.0 X 1.25 = 27.50 AMPS

    BREAKER CAPACITY = 30 AMPS

    UMINVERTER

    FINANCE METER

    AC DISCONNECT

    MAIN SERVICEPANEL

    ELECTRICAL EQUIP. ELEVATIONSCALE: NTS 2

    FLOOR

    DC DISCONNECT

    ROOFTOPJUNCTION BOX

    TO ARRAYTO UTILITYPOLE

    FM

    LOAD CENTER

    BACKFEED CALCULATION200 X 1.2 = 240 AMPS240 - 200 = 40 MAX. BACKFEED

    FM

    UM

    JB

    JB

    FROM UTILITYPOLESMA 5kW

    INVERTER WITHINTEGRATED

    AC/DCDISCONNECT

    LGATE 101CPF METER

    60A, ACDISCONNECT

    TOLOADS

    4 - #10 AWG, USE-21 - #8 AWG, BARE COPPER GROUND

    4 - #10 AWG, THWN-21 - #8 AWG, THWN-2

    3 - #8 AWG, THWN-21 - #8 AWG, THWN-2

    2 - #10 AWG, THWN-21 - #8 AWG, THWN-2

    JUNCTIONBOX

    JUNCTIONBOX

    EXISTING 200A,240VAC

    DISCONNECT

    EXISTING 200A,240VAC, MSP

    40A, 2POLE, PVBREAKER

    DCAC

    DCAC

    12/22/2015

    XXX

    BAC-XXX

    STRING-112 SUNMODULE 265W

    MODULES

    STRING-212 SUNMODULE 265W

    MODULES

    STRING-112 SUNMODULE 265W

    MODULES

    2 - #10 AWG, THWN-21 - #8 AWG, COPPER GROUND

    SMA 3kWINVERTER WITH

    INTEGRATEDAC/DC

    DISCONNECT

    STRING 2 CIRCUIT CURRENT CALCULATION:1 X 12 SUNMODULE 265W MODULESCONNECTED TO 1 SMA 3kW INVERTER

    MAX. INVERTER OUTPUT POWER: 3000WNOMINAL VOLATGE: 240VRATED OUTPUT CURRENT: 15 AMPS

    OVERCURRENT PROTECTION12.0 X 1.25 = 15.00 AMPS

    BREAKER CAPACITY = 15 AMPS

    LOADCENTER

    125A,240V

    30A, 2P240VAC15A, 2P240VAC

    (E) GEC

    CLIENT:

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx

  • SHEET:TITLE:

    PV-5

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    DATA SHEET:MODULE & INVERTER

    DESCRIPTION DATE REVISION 12/22/2015

    XXX

    BAC-XXX

    CLIENT:

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx

  • SHEET:TITLE:

    PV-6

    REVISIONS: DATE:

    DESIGNBY:

    JOBNO.:

    DATA SHEET:MOUNT & RAIL

    DESCRIPTION DATE REVISION 12/22/2015

    XXX

    BAC-XXX

    CLIENT:

    XXX XXXX1111, XXX STREETXXXXX, CA XXXXTel: (xxx) xxx xxxx