1
SOLAR HART TANK 7'-6" 8'-0 " 3/14/2010 8:11:30 PM PLACE OF FUTURE INSTALLATION 08 SCALE: 3/8" = 1'-0" COLLECTOR SUB FRAME INSTALLATION 01 SCALE :N.T.S. STREET VIEW 02 SCALE :1" = +/- 40'-0" ARIAL PHOTOGRAPH 04 SCALE :N.T.S. SAMPLE PHOTOGRAPH - 302 J SYSTEM N 09 SCALE: N.T.S. STORAGE TANK ATTACHMENT 10 SCALE: N.T.S COLLECTOR ATTACHMENT DETAIL 11 SCALE: N.T.S. TOP VIEW WD/ RUNNEER INSTALLATION 05 SCALE :N.T.S. ENGINEERING NOTES 06 SCALE :N.T.S. CLEARANCE REQUIREMENTS 07 SCALE :N.T.S. WD RUNNER INSTALLATION DETAIL 16" OR 24" OC. UNISTRUT P1000T FLASH AND SEAL ALL ROOF PENETRATIONS EXISTING ROOF RAFTER OR TRUSS ATTACH EXTRUSION TO OEM BOLTS SOLAHART 1846 COLLECTOR MOUNTING EXTRUSION ATTACH COLLECTOR W/ 2 CR SHEET MET. SCREWS W/ OEM MOUNTING HARDWARE 5/16" SS BOLT SHEET NO: PUBLISHED: SHEET NAME: DRAWN: THIS IS A SINGLE SHEET PLAN CHECKED: SB AG 0065_Miller_Clearwater_FL.dwg COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/ST/ 0065_Miller_Clearwater_FL.dwg ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF REVISIONS: THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL. THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE PERMITS. EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL COPY OF THIS PLAN. ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE AND NATIONAL ELECTRICAL CODE. INSTALLATION OF A SOLAR THERMAL SYSTEM 1649 LONG BOW LN LARGO 33764 ROOF MOUNT DESIGNED PER: ASCE 7-05, APPLICABLE CODE: FLORIDA BUILDING CODE 2007 W/09 SUPP. EXPOSURE: WIND LOAD: BLDG. IP. CATEGORY: 123 MPH B II STRUCTURAL : GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN _ PSF WIND FORCES: ASCE 7 PRESSURE ZONE DIAGRAM (PAGE 5 AT 1ST LINK) MAY BE VIEWED AT THE FOLLOWING LINKS: http://www.unirac.com/pdf/ii227.pdf http://www.unirac.com/pdf/ii206.pdf 25 PZ1_18.9; PZ2_28.8; PZ3_47.9 OWNER: 1649 LONG BOW LN, CLEARWATER FL 33764 MILLER, MITCHELL AHJ: LARGO UTILITY: N/A LEGAL DESCRIPTION: PARCEL ID: 25-29-15-70200-100-0502 PINELLAS GROVES NE 1/4, S 150FT OF N 560FT OF LOT 5 & S 150FT OF N 560FT OF E 105FT MOL OF LOT 6 INCL PT R/W NOT VAC SOLAR SYSTEM: 300 L (80GAL) 2 COLLECTOR - 1038 LB FULL DIMENSIONS: 96" X 90" SOLAHART 302J SRCC # 300-2001016C PLACE OF FUTURE INSTALLATION INSTALLATION NOTES SOLAHART GRAVITY FLOW SOLAR DOMESTIC WATER HEATER THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN WWW.GEZELMANPE.COM/ST/0065_MILLER_CLEARWATER_FL.PDF. ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DETAIL AND/OR SPECIFICATION HEREON AND AN OEM PROVISION, OEM SHALL PREVAIL. OEM INFORMATION MAY BE ACCESSED: HTTP://WWW.SOLAHART.COM/SOLAHART-FOR-PROFESSIONALS/ TECHNICAL-INFORMATION.ASPX HEATING PROCESS - THIS IS A CLOSED LOOP SYSTEM USING A HEAT EXCHANGER IN THE TANK AND FOOD GRADE ANTI-FREEZE AS THE HEAT TRANSFER FLUID. IT ALSO INCORPORATES A GRAVITY FLOW DESIGN WITH THE TANK LOCATED ABOVE THE COLLECTORS. COLDER HEAT TRANSFER FLUID IS DENSER THAN WARM. IT SETTLES AND ENTERS THE BOTTOM OF THE COLLECTORS. AS THE SUN, STRIKES THE COLLECTORS THE TRANSFER FLUID HEATS AND RISES ENTERING THE STORAGE TANK WHERE IT CAUSES COLDER TRANSFER FLUID TO DROP INTO THE BOTTOM OF THE COLLECTORS IN A CONTINUOUS PROCESS SO LONG AS THE SUN IS SHINING. STRUCTURAL LOADING - THIS SYSTEM IMPOSES LESS THAN 18-PSF GRAVITY LOADING UPON THE ROOF FRAMING - WHICH IS WITHIN ALLOWABLE LIMITS. CONTRACTOR IS DIRECTED TO PLACE THE TANK AS CLOSE TO THE RIDGE AS POSSIBLE. PZ2 WIDTH IS 3 FEET. WIND LOAD POSITIVE PRESSURE IS NEGLIGIBLE. WIND UPLIFT LOADS ARE: PZ1_-17; PZ2_-28.8 PSF; PZ3_-47.9 PSF. LOCATE COLLECTOR AS HIGH ON ROOF AS POSSIBLE POSITION UNISTRUT OVER ROOF FRAMING, FASTEN THRU WATER PROOFING W/ 5 16 X 3" SS LAGS UNISTRUT P1000T HG CHANNEL NUT UNISTRUT P1000T HG UNISTRUT P1000T HG HTTP://WWW.UNISTRUT.COM/

SOLAR THERMAL SYSTEMsolahart 302j srcc # 300-2001016c place of future installation installation notes solahart gravity flow solar domestic water heater the details specified on this

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SOLAR THERMAL SYSTEMsolahart 302j srcc # 300-2001016c place of future installation installation notes solahart gravity flow solar domestic water heater the details specified on this

SOLAR HART TANK

7'-6"

8'-0"

3/14/2010 8:11:30 PM

PLACE OF FUTURE INSTALLATION

08SCALE: 3/8" = 1'-0"

COLLECTOR SUB FRAME INSTALLATION

01SCALE :N.T.S.

STREET VIEW02

SCALE :1" = +/- 40'-0"

ARIAL PHOTOGRAPH04

SCALE :N.T.S.

SAMPLE PHOTOGRAPH - 302 J SYSTEMN

09SCALE: N.T.S.

STORAGE TANK ATTACHMENT10

SCALE: N.T.S

COLLECTOR ATTACHMENT DETAIL11

SCALE: N.T.S.

TOP VIEW WD/ RUNNEER INSTALLATION

05SCALE :N.T.S.

ENGINEERING NOTES06

SCALE :N.T.S.

CLEARANCE REQUIREMENTS07

SCALE :N.T.S.

WD RUNNER INSTALLATION DETAIL 16" OR 24" OC.

UNISTRUT P1000T

FLASH AND SEAL ALL ROOF PENETRATIONS

EXISTING ROOF RAFTER OR TRUSS

ATTACH EXTRUSION TO OEM BOLTS

SOLAHART 1846 COLLECTOR MOUNTING EXTRUSION

ATTACH COLLECTOR W/ 2 CR SHEET MET. SCREWS

W/ OEM MOUNTING HARDWARE5/16" SS BOLT

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN:

THIS IS A SINGLE SHEET PLAN

CHECKED:SB AG

0065_Miller_Clearwater_FL.dwg

COPY RIGHT & INTELLECTUAL PROPERTY NOTICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

SH

YP

ER

LIN

K A

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E A

CC

ES

SE

D A

T:

WW

W.G

EZ

ELM

AN

PE

.CO

M/S

T/0065_Miller_Clearwater_FL.dwg

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN

GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700

(ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE

CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS

THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING

SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT:

HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

REVISIONS:

THIS PLAN IS VOID WITHOUT MY SIGNATURE & RAISED SEAL.

THIS PLAN MAY NOT BE PLACED ON FILE FOR PULLING MULTIPLE

PERMITS. EACH PERMIT PULLED REQUIRES ITS OWN RAISED SEAL

COPY OF THIS PLAN.

ALLEN GEZELMAN

16502 HANNA RD.

LUTZ, FLORIDA 33549

PH. 813 650 7246

FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEREQUIREMENTS OF THE CURRENTFLORIDA BUILDING CODE ANDNATIONAL ELECTRICAL CODE.

INSTALLATION OF A

SOLAR THERMAL SYSTEM

1649 LONG BOW LN LARGO 33764

ROOF MOUNT

DESIGNED PER: ASCE 7-05,

APPLICABLE CODE:

FLORIDA BUILDING CODE 2007 W/09 SUPP.

EXPOSURE:

WIND LOAD:

BLDG. IP. CATEGORY:

123 MPH

B

II

STRUCTURAL: GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN _ PSF

WIND FORCES:

ASCE 7 PRESSURE ZONE DIAGRAM (PAGE 5 AT 1ST LINK) MAY BE VIEWED AT THE FOLLOWING LINKS:

http://www.unirac.com/pdf/ii227.pdf http://www.unirac.com/pdf/ii206.pdf

25

PZ1_18.9; PZ2_28.8; PZ3_47.9OWNER:

1649 LONG BOW LN, CLEARWATER FL 33764

MILLER, MITCHELL

AHJ:LARGO

UTILITY:N/A

LEGAL DESCRIPTION:PARCEL ID: 25-29-15-70200-100-0502

PINELLAS GROVES NE 1/4, S 150FT OF N 560FT OF LOT 5

& S 150FT OF N 560FT OF E 105FT MOL OF LOT 6

INCL PT R/W NOT VAC

SOLAR SYSTEM:

300 L (80GAL) 2 COLLECTOR - 1038 LB FULL

DIMENSIONS: 96" X 90"

SOLAHART 302J

SRCC #

300-2001016C

PLACE OF FUTURE INSTALLATION

INSTALLATION NOTES SOLAHART GRAVITY FLOW SOLAR DOMESTICWATER HEATERTHE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BETHE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) ANDINSTALLERS.USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS

PLAN WWW.GEZELMANPE.COM/ST/0065_MILLER_CLEARWATER_FL.PDF.ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTALINFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEMDETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A

CONFLICT SHOULD OCCUR BETWEEN A DETAIL AND/OR SPECIFICATIONHEREON AND AN OEM PROVISION, OEM SHALL PREVAIL. OEMINFORMATION MAY BE ACCESSED:

HTTP://WWW.SOLAHART.COM/SOLAHART-FOR-PROFESSIONALS/TECHNICAL-INFORMATION.ASPX

HEATING PROCESS - THIS IS A CLOSED LOOP SYSTEM USING A HEATEXCHANGER IN THE TANK AND FOOD GRADE ANTI-FREEZE AS THE HEATTRANSFER FLUID. IT ALSO INCORPORATES A GRAVITY FLOW DESIGN WITHTHE TANK LOCATED ABOVE THE COLLECTORS. COLDER HEAT TRANSFERFLUID IS DENSER THAN WARM. IT SETTLES AND ENTERS THE BOTTOM OFTHE COLLECTORS. AS THE SUN, STRIKES THE COLLECTORS THE TRANSFERFLUID HEATS AND RISES ENTERING THE STORAGE TANK WHERE IT CAUSESCOLDER TRANSFER FLUID TO DROP INTO THE BOTTOM OF THECOLLECTORS IN A CONTINUOUS PROCESS SO LONG AS THE SUN ISSHINING.STRUCTURAL LOADING - THIS SYSTEM IMPOSES LESS THAN 18-PSFGRAVITY LOADING UPON THE ROOF FRAMING - WHICH IS WITHINALLOWABLE LIMITS. CONTRACTOR IS DIRECTED TO PLACE THE TANK ASCLOSE TO THE RIDGE AS POSSIBLE. PZ2 WIDTH IS 3 FEET. WIND LOADPOSITIVE PRESSURE IS NEGLIGIBLE. WIND UPLIFT LOADS ARE: PZ1_-17;PZ2_-28.8 PSF; PZ3_-47.9 PSF.

LOCATE COLLECTOR AS HIGH ON ROOFAS POSSIBLE

POSITION UNISTRUT OVER ROOF FRAMING, FASTEN

THRU WATER PROOFING W/ 516 X 3" SS LAGS

UNISTRUT P1000T HG

CHANNEL NUT

UNISTRUT P1000T HG

UNISTRUT P1000T HG

HTTP://WWW.UNISTRUT.COM/