8
1 Publication 6181P-IN006A-EN-P - January 2006 Installation Instructions Solid State Drive Upgrade Kit Catalog No. 6189V-12TSSD4, 6189V-12NSSD4, 6189V-12TSSD8, 6189V-12NSSD8, 6189V-15TSSD4, 6189V-15NSSD4, 6189V-15TSSD8, 6189V-15NSSD8 Inside . . About this Product This document shows how to replace the hard disk drive (HDD) with a solid state drive (SSD) in the 12" and 15" models of the 6181P VersaView Integrated Display Computers. For See Page Safety Precautions 2 Parts List 3 Required Tools 3 Remove the Hard Disk Drive 3 Install the Solid State Drive 5 Add or Remove Memory 6 Additional Resources 8 Solid State Drive Upgrade Kit Drive Size Computer Compatibility Series Rev 6189V-12TSSD4/SSD8 4GB/8GB 6181P-12TPXXXX B C 6181P-12TSXXXX B C 6189V-12NSSD4/SSD8 4GB/8GB 6181P-12NPXXXX B C 6181P-12NSXXXX B C 6181P-2PXXXX B B 6189V-15TSSD4/SSD8 4GB/8GB 6181P-15TPXXXX B B 6181P-15TSXXXX B B 6189V-15NSSD4/SSD8 4GB/8GB 6181P15NPXXXX B B 6181P15NSXXXX B B

Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

Installation Instructions

Solid State Drive Upgrade Kit

Catalog No.6189V-12TSSD4, 6189V-12NSSD4, 6189V-12TSSD8, 6189V-12NSSD8, 6189V-15TSSD4, 6189V-15NSSD4, 6189V-15TSSD8, 6189V-15NSSD8

Inside . .

About this Product This document shows how to replace the hard disk drive (HDD) with a solid state drive (SSD) in the 12" and 15" models of the 6181P VersaView Integrated Display Computers.

For See Page

Safety Precautions 2

Parts List 3

Required Tools 3

Remove the Hard Disk Drive 3

Install the Solid State Drive 5

Add or Remove Memory 6

Additional Resources 8

Solid State DriveUpgrade Kit

Drive Size

Computer Compatibility

Series Rev

6189V-12TSSD4/SSD8 4GB/8GB 6181P-12TPXXXX B C

6181P-12TSXXXX B C

6189V-12NSSD4/SSD8 4GB/8GB 6181P-12NPXXXX B C

6181P-12NSXXXX B C

6181P-2PXXXX B B

6189V-15TSSD4/SSD8 4GB/8GB 6181P-15TPXXXX B B

6181P-15TSXXXX B B

6189V-15NSSD4/SSD8 4GB/8GB 6181P15NPXXXX B B

6181P15NSXXXX B B

1 Publication 6181P-IN006A-EN-P - January 2006

Page 2: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

2 Solid State Drive Upgrade Kit

Safety Precautions Observe the following precautions when working with the computer’s hard and solid state disk drive:

• Do not touch internal components unnecessarily.

• Always handle the drive by its metal frame.

• Store the drive in an anti-static bag when it is not installed.

• Never disconnect or install a drive with the power turned on.

ATTENTION

!Failure to follow proper safety procedures could result in severe electrical shock or damage to the VersaView 6181P Integrated Display Computers.

ATTENTION

!Disconnect all power from the computer before removing and installing components. Failure to disconnect power could result in severe electrical shock or damage to the computer.

ATTENTION

!Electrostatic discharge (ESD) can damage the computer and components. Make sure you work in a static-safe environment and wear a grounding strap whenever handling circuit boards, memory or other internal components.

ATTENTION

!Mechanical shock can damage both HDD or SDD drives. Do not drop or bump the drive.

Publication 6181P-IN006A-EN-P - January 2006

Page 3: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

Solid State Drive Upgrade Kit 3

Parts List The solid state drive upgrade kit consists of:

• Mounting bracket (1)

• Adapter retention clamp (1)

• M3 flat head screws (2)

• 4GB or 8GB solid state drive with WIN XP FES Image(1)

• DIMM512MB memory sticks (2)

• M3 pan head screws (4)

• Tie wraps (2)

Required Tools Use a Phillips #2 screwdriver for installation.

Remove the Hard Disk Drive 1. Disconnect power from the computer.

2. Remove the screws securing the back cover.

3. Remove the four screws that fasten the hard disk drive assembly to the chassis.

4. Lift the hard disk drive assembly out of the chassis.

1200P 1500P

IMPORTANT Note the location and orientation of all cables before you remove the existing hard drive and cabling, so that you can reattach them correctly.

Publication 6181P-IN006A-EN-P - January 2006

Page 4: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

4 Solid State Drive Upgrade Kit

5. Open the hard disk drive brackets.

6. Disconnect the ribbon cable from the hard disk drive.

7. Lift the hard disk drive out of the bracket.

Hard Disk Drive Brackets

1500P

Rubber Shock Mount Strips

Hard Disk Drive

Rubber Shock Mount Strips

Hard Disk Drive

Hard Disk Drive Brackets

1200P

Publication 6181P-IN006A-EN-P - January 2006

Page 5: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

Solid State Drive Upgrade Kit 5

Install the Solid State Drive

1200P and 1500P Installation

1. Attach the SSD to the mounting plate using (4) M3 pan head screws.

2. Attach the mounting plate and drive to the chassis using (4) M3 pan head screws.

Use existing screws from the HDD mounting assembly.

3. Connect the IDE adapter/cable to the SSD.

4. Place the adapter retention clamp over the adapter and line up the screw holes.

5. Fasten the retention clamp to the mounting bracket with (2) M3 flat head screws.

ATTENTION

!Electrostatic discharge (ESD) can damage the computer and components. Make sure you work in a static-safe environment and wear a grounding strap whenever handling circuit boards, memory or other internal components.

Solid State Disk Drive

Mounting Plate

Retention Clamp

IDE Adapter

Chassis

1200P

Publication 6181P-IN006A-EN-P - January 2006

Page 6: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

6 Solid State Drive Upgrade Kit

Add or Remove Memory The CPU board in the computer has two sockets. Each socket supports a Dual In-Line Memory Module (DIMM).

Guidelines for Replacing Memory

When adding memory to the CPU board, follow these guidelines:

• Always handle the memory module by the ends not by the contacts.

• Store memory in a sealed anti-static bag when it is not installed.

• Never install or remove memory with the power turned on.

Replace the Memory

1. Identify the memory module that is in the socket.

If the memory stick is either 6189V-DIMM128 or 6189V-DIMM256, you must remove it. Install (2) 6189V-DIMM512 memory sticks instead.

2. Remove the existing memory module from the CPU card by clipping the cable tie and pressing outward on the retaining latches.

The DIMM sockets are on the side of the CPU board.

3. To install a new DIMM, hold the memory module only by the edges as you remove it from its anti-static package.

4. Position the DIMM so that the small notches in the bottom edge of the DIMM align with the notches in the DIMM socket on the CPU card.

ATTENTION

!Failure to follow proper safety precautions could result in severe electrical shock and/or damage to the computer.

ATTENTION

!Electrostatic Discharge (ESD) can damage the computer and components. Make sure you work in a static-safe environment and wear a grounding strap whenever handling circuit boards, power supply, memory sticks or other internal components.

Publication 6181P-IN006A-EN-P - January 2006

Page 7: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

Solid State Drive Upgrade Kit 7

The retaining latches should be fully disengaged when attempting to install a DIMM.

5. Press down firmly and uniformly on the DIMM to seat it in the socket.

The latches should engage in the DIMM locking slot to secure the part in place.

6. Replace the tie wrap around the DIMM and latches to fully secure the DIMM in place.

7. Replace the back cover.

Label Placement After SSD installation is complete attach the following labels to the back panel:

• COA label

• IDS image label

• SSD upgrade label

Place SSD upgrade label on the back panel being careful not to cover up any vent or screw.

Place the IDS image and COA labels over existing labels.

Memory Module Location

Publication 6181P-IN006A-EN-P - January 2006

Page 8: Solid State Drive Upgrade Kit - Rockwell Automation · 2012-05-31 · Publication 6181P-IN006A-EN-P - January 2006 2 Solid State Drive Upgrade Kit Safety Precautions Observe the following

Additional Resources For additional information on the VersaView computers, refer to publication 6181P-UM001, VersaView Integrated Display Computers user manual.

You can download an electronic version of this publication from the Rockwell Automation website:

http://www.rockwellautomation.com/literature

Allen-Bradley and VersaView are registered trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Label Placement

SSD Upgrade Label

IDS Image Label

COA label

Publication 6181P-IN006A-EN-P - January 2006 8 PN 41061-369-01(1)Copyright © 2006 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.