SOLUTIONS FOR DATA CENTERS LR8400: Temperature LR8400: Voltage PW3360: Instantaneous voltage PW3360: Instantaneous current PW3360: Instantaneous power factor Implement Reliable Maintenance Programs with Efficient Measurement Data Management EARTH TESTER FT6031 6 Server Rooms Substations In-house Generator Storage Batteries UPS 5G Antennas Electrical Panels Electrical Panels HVAC BATTERY TESTER BT3554 2 CLAMP ON POWER LOGGER PW3365 3 MEMORY HiLOGGER LR8450 4 CLAMP METER INSULATION TESTER DIGITAL MULTIMETER ※ GENNECT not supported 5 POWER QUALITY ANALYZER PQ3198 1 3 MEMORY HiCORDER MR6000 1 GENNECT Cross Send data wirelessly to your mobile device to easily manage data on site GENNECT One Transfer data to your PC via LAN to get a complete picture of all measured signals HUB Power quality Power consumption Temperature & humidity List or graph data in real-time • Verify current waveforms or place data labels right on the site photo • Use recorded data to make PDF reports Bluetooth ® 2 Diagnose Condition of Emergency Batteries Record & Analyze POWER ISSUES 1 Record sudden issues that can't be captured by the SNMP Identify POWER CONSUMPTION 3 Regular Inspections of ELECTRICAL PANELS 5 6 Ground Resistance INSPECTION Temperature/ Humidity Control SERVER ROOMS 4 Thermal Management of 5G Antennas 4 4 5 1 3 1 1 Grounding Rod 6 2 1

SOLUTIONS OR ATA CENTERS Solutions for...PW3365 3 MEMORY HiLOGGER LR8450 4 CLAMP METER INSULATION TESTER DIGITAL MULTIMETER ※ GENNECT not supported 5 POWER QUALITY ANALYZER PQ3198

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SOLUTIONS OR ATA CENTERS Solutions for...PW3365 3 MEMORY HiLOGGER LR8450 4 CLAMP METER INSULATION TESTER DIGITAL MULTIMETER ※ GENNECT not supported 5 POWER QUALITY ANALYZER PQ3198

Maintain the Integrity ofYour Mission-Critical Equipment

SOLUTIONS FOR DATA CENTERS

LR8400: Temperature

LR8400: Voltage

PW3360: Instantaneous voltage

PW3360: Instantaneous current

PW3360: Instantaneous power factor

Implement Reliable Maintenance Programs with Efficient Measurement Data Management

EARTHTESTERFT6031

6

Server Rooms

Substations

In-house Generator

Storage Batteries

UPS

5G Antennas

Electrical Panels

Electrical Panels

HVAC

BATTERYTESTERBT3554

2

CLAMP ONPOWER LOGGERPW3365

3

MEMORY HiLOGGERLR8450

4

CLAMP METERINSULATION TESTERDIGITAL MULTIMETER

※ GENNECT not supported

5

POWER QUALITY ANALYZERPQ3198

1 3

MEMORY HiCORDERMR6000

1

GENNECT CrossSend data wirelessly to your mobile device to easilymanage data on site

GENNECT OneTransfer data to your PC via LAN to get a completepicture of all measured signals

HUB

Powerquality

Powerconsumption

Temperature& humidity List or graph data in real-time

• Verify current waveforms or place data labels right on the site photo• Use recorded data to make PDF reportsBluetooth®

2Diagnose Condition of

EmergencyBatteries

Record & AnalyzePOWER ISSUES

1

Record sudden issuesthat can't be captured

by the SNMP

IdentifyPOWER

CONSUMPTION

3

Regular Inspections ofELECTRICAL

PANELS

5

6Ground Resistance

INSPECTION

Temperature/Humidity Control

SERVER ROOMS

4Thermal

Management of5G Antennas

4

451

3

1

1

Grounding Rod

6

21

Page 2: SOLUTIONS OR ATA CENTERS Solutions for...PW3365 3 MEMORY HiLOGGER LR8450 4 CLAMP METER INSULATION TESTER DIGITAL MULTIMETER ※ GENNECT not supported 5 POWER QUALITY ANALYZER PQ3198

HEADQUARTERS 81 Koizumi, Ueda, Nagano 386-1192 Japan

https://www.hioki.com/

All information correct as of Feb. 21, 2019. All specifications are subject to change without notice. Date-CenterE1-02E

DISTRIBUTED BY

Note: Company names and product names appearing in this catalog are trademarks or registered trademarks of various companies.

Record sudden problems missed by the SNMP*

Receiving Equipment UPS

PQ3198IEC 61000-4-30Class A PQA

Inrush Current

Transients

Equipment Damage and Malfunction Due to Power QualityClarify trouble spots via simultaneous recording of 3 systems

UPS

Main

Sub

Switch Server

MR60008966 x 5

U8977 x 3

Reliable Preventive Maintenance of UPSDiagnose deterioration of lead-acid batteries (also measure lithium-ion batteries)

Reach deep within battery racksL2020 test lead with L-shaped tip

BT3554

Distribution panelAC power InverterConverter

Battery

Harmonicnoise

Measure correctly even in noisy environmentsAddress inverter noise emitting from UPS

Measure mixed AC & DC signals

Founded in 1935, Hioki has grown to become a world leader in providing consistent delivery of test and measuring instruments. By integrating both R&D and manufacturing in a central facility, we succeed in implementing a fully sustainable end-to-end product innovation life cycle to deliver instruments characterized by precision, safety and quality to customers around the world.

JAPANNAGANO UEDA City

85 years ofmeasurement

expertise

Thin jaw tackles complicated wiring with easeAC/DC CLAMP METER CM4376

Innovativethin design Traditional jaw

*SNMP: Simple Network Management Protocol : a protocol used to monitor the live and operational status of IP devices - widely used for measuring rack temperature and current

Centrally manage data from allLAN-connected instruments with a PC

Connect toGENNECT One

1