  • TROUBLESHOOTING

    SPLIT AIR CONDITIONERWITH HEAT PUMP

    SOPHIA

  • 1.1 Indoor Unit Error Display Operation

    lamp Timer lamp Display LED STATUS

    ☆ 1 time X E0 Indoor unit EEPROM parameter error

    ☆ 2 times X E1 Indoor / outdoor units communication error

    ☆ 3 times X E2 Zero-crossing signal detection error

    ☆ 4 times X E3 Indoor fan speed has been out of control

    ☆ 5 times X E4 Indoor room temperature sensor T1 open circuit or short circuit

    ☆ 6 times X E5 Evaporator coil temperature sensor T2 open circuit or short circuit ☆ 7 times X EC Refrigerant leakage detection

    ☆ 1 times O F0 Overload current protection

    ☆ 2 times O F1 Outdoor ambient temperature sensor T4 open circuit or short circuit

    ☆ 3 times O F2 Condenser coil temperature sensor T3 open circuit or short circuit

    ☆ 4 times O F3 Compressor discharge temperature sensor TP open circuit or short circuit ☆ 5 times O F4 Outdoor unit EEPROM parameter error

    ☆ 6 times O F5 Outdoor fan speed has been out of control

    ☆ 1 times ☆ P0 IPM malfunction or IGBT over-strong current protection

    ☆ 2 times ☆ P1 Over voltage or over low voltage protection

    ☆ 3 times ☆ P2 High temperature protection of IPM module or compressor top ☆ 4 times ☆ P3* Outdoor ambient temperature too low.

    ☆ 5 times ☆ P4 Inverter compressor drive error

    ☆ 6 times ☆ P5 Indoor units mode conflict (multi-zone ONLY)

    ☆ 7 times ☆ P6 Low pressure protection(Only for 36K) O(light) X(off) ☆(flash)

    *P3 1) In heating mode, when the outdoor temperature is lower than -25℃ for 1 hour, the indoor unit display error code P3. 2) If the outdoor temperature is higher than -22℃ for 10 minutes and compressor stop for 1 hour or outdoor temperature is higher than -5℃ for 10 minutes, then the unit will return to work. * Fault Symptom: The display board shows a garbled code or a code that is not an error code found in the service manual nor a temperature reading. Trouble shooting: Use the remote controller. If the unit does not respond to the remote, the indoor PCB needs to be replaced; if the unit does respond, then the display board needs to be replaced

  • 1.2 Outdoor unit error display(TBD) For CH-09SPH-115VO, CH-12SPH-115VO, CH-09SPH-230VO, CH-12SPH-230VO,

    N

    1

    17122000019195

    1

    1

    [ 1. 6] 2015-09-30

    US- KFR- 35W/ BP3N1- ( 115V+RX62T+41560) . D. 13. WP2- 1

    L-IN

    N-IN

    7805

    S

    HEAT

    14-

    WAY

    AC-F

    ANHE

    AT2

    Eart

    h

    DC-F

    AN

    PMV

    TESTPORT

    BLACKW

    REDV

    BLUEU

    CN4_1CN4_2 CN4_3CN4_4

    REACTOR

    CAP

    T3T4TP

    NN

    N

    H

    L

    CN25

    CN31

    ACAC

    +-

    BR1

    +E2

    CN21

    RC1

    E304

    ZR2

    +- AC

    OUTI N

    ~~

    RY3ASJ-S-112DMG

    R191

    I C105

    CN15

    ZR5

    ZR4

    R628

    C618

    R118

    R123

    R122

    C324

    I C2

    R421

    R621

    D103

    C413

    C306

    C319

    I PM301

    R176

    R175

    +

    E109

    C107

    T401

    R410

    R409

    R316

    3W- 10m¦ ¡̧ À1%

    D407++

    C110

    R623

    R602

    C624

    RY3

    R196

    D610

    C318

    C316 C314

    C134

    +

    E605

    E303

    E208

    E206E30

    2

    E300

    CN50

    R523

    R522

    R521

    R520

    R519

    R518

    R517

    R323

    R322

    R321

    R320

    R319

    R318

    R317

    I C301

    C513

    C512C511

    C323

    C321

    C320

    R426

    R314R306

    R305R304

    R303C311

    C310

    C309

    C308

    C307

    CN28

    CN29

    CN30 C520

    C1

    +E106

    C101

    D101

    C611

    R171

    D602

    I C102

    Rdi

    D404

    D401

    CN6

    ZR1

    RY2

    R626

    R620

    R619

    R618

    R617

    R616

    R615

    R612R611 R610R608

    R607

    R605

    R603

    R601

    R528

    R516

    R513

    R508R506

    R504

    R502

    R429

    R428

    R427

    R408

    R407

    R406

    R405

    R404

    R403

    R315

    R301

    R190

    R188R187

    R186

    R185

    R182

    R181R180

    R179

    R178

    R174

    R173 R

    170

    R169

    R168

    R165

    R157

    R155R154

    R152

    R150

    R149

    R148

    R147

    R144

    R143

    R142R140

    R138

    R137

    R136

    R135

    R133

    R132

    R131

    R130

    R129

    R128

    R127R126

    R125R124

    R121

    R120

    R117

    R116

    R115

    R114 R1

    12R1

    11

    R110

    R108

    R107

    R106

    R105

    R102

    R101

    R2

    Q101

    OSC101

    NTC2

    +LED101

    IC60

    3

    IC60

    2

    IC60

    1

    I C403

    I C401

    I C1

    +

    E602

    +

    E401

    +

    E108 + E107

    +E105

    +

    E103

    +

    E102

    +

    E101

    +

    E1

    +

    E3

    +

    DZ601

    DZ304 DZ303 DZ302DZ301

    +DZ203

    +

    DZ202

    D406

    D402

    +

    D2

    +

    D1

    1CN505

    CN7

    C615

    C614

    C612

    C606

    C605

    C601

    C509

    C508

    C507

    C506

    C505

    C504

    C503

    C412

    C410

    C409

    C408

    C405

    C404

    C403

    C402

    C401

    C322C312

    C305

    C303

    C302

    C274

    C273C272

    C271

    C133

    C132

    C131

    C130C129

    C128

    C127

    C126

    C125

    C124

    C123

    C121

    C120

    C119

    C118

    C116

    C115

    C114

    C113

    C112

    C111

    C106

    C105C104

    C103

    C102

    C16

    C11 C10C7 C6

    C5

    C4

    C3

    C2

    + E280 +E281

    + E282

    +

    E283

    +

    E404

    +

    E407

    PTC1

    +

    E409D104

    R401

    R103

    C117

    R195

    R172

    +

    DZ204 C275

    R156R60

    4

    R104

    I C101

    I C104

    RY4

    +

    E410

    +

    E405

    FUSE1T20A/ 250VAC

    C9A

    CN1A

    I C404

    +

    D403

    I C103

    C613

    CN3

    CN2

    CN1

    CN16

    +

    DZ201

    L2L3L4L5

    C135

    CN17

    R21 R23

    R158

    RY5

    21 43

    3 4

    ON

    1 2

    ON

    SW2

    RC2

    DSA1

    I C405

    +

    CN60

    C8

    L1

    R1

    IPM5

    01

    C122

    CommentComment

    RY1

    CN507

    R606

    3W-1

    0m¦

    ¡̧À1%

    R2530. 75¦ /̧ 1W

    R2540. 75¦ /̧ 1W connect to compressor heaterwhen is on, 100-130V AC outpu

    connect to 4-way Valvewhen is on, 100-130VAC OUTPUT

    connect to PFC Capacitorwhen is on, 100-130V ACoutput

    connect to reactorwhen is on, 100-130V AC output

    connect toGround

    connect to N-line

    (100-130VAC INPUT)

    connect to L-line

    (100-130VAC INPUT)

    connect to indoor unitcommunication

    U

    V

    W

    10- 230VAC¡ ̄ ( r unni ng)

    0VAC ( st andby)

    connect t o DC Mot or

    external driver motor

    connect to Electric Expansi

    pipe temp.sensor& room temp.sensor&Exaust temp. sensor

    6 5 4 3

    TP T4

    RT

    RT+5V

    DC

    +5V

    DC

    +12V DC pul se wave bet ween (+1) -G

    +12V DC pul se wave bet ween (+2) -G+12V DC pul se wave bet ween (+3) -G

    +12V DC pul se wave bet ween (+4) -G

    +12V DC+12V DC

    6 5

    4 3

    2 1

    AC fan motor5

    4

    3

    2

    1low speed

    N linehigh speed

    FAN Starting Capacitor

    FAN Starting Capacitor

    connect to chassis heaterwhen is on, 100-130VAC OUTPUT

    UVW 0VAC(standby)

    10-230VAC¡(̄running)

    connect tocompressor

    connect to PCcommunication

    EEPROM ProgrammerPort

    Test Port

    bridge

    IPM for compressor

    IPM for DC FAN

    P

  • For CH-09SPH-230VO, CH-12SPH-230VO, CH-18SPH-230VO, CH-18SPH-230VO

    +

    T4TP

    T3

    N

    L

    H

    NN

    RdiHave

    Low- Fr e

    YESNO

    No

    U

    BLUE

    VRED

    WBLA

    CK

    TESTPORT

    PMV

    DC-F

    AN

    DR_L

    DR_N

    Eart

    h

    HEAT2

    AC-F

    AN4-

    WAY

    HEAT

    1

    S

    7805

    N-IN

    L-IN

    KFR- 35W/ BP3N1- ( RX62T+41560) . D. 13. WP2- 1 [ 1. 8] 2015- 12- 31

    1 1

    17122000002718

    1

    E304E208

    C10

    RC3

    CN22

    ZR4

    R696R695

    C696

    C695

    ZR5

    C9

    IPM5

    01

    L1

    C8

    CN60

    +

    I C405

    DAS1

    RC2

    ON

    21

    ON

    43

    341 2

    SW2

    RY5

    R158

    R23R21

    CN17

    CN11

    CN10

    C135

    L5 L4 L3 L2

    +

    DZ201

    L601

    CN16

    CN1

    CN2

    CN3

    CN3_1

    C613

    I C103

    CN507

    +

    D403

    I C404

    CN1A

    FUSE1T20A/ 250VAC

    E405

    E410

    RY4

    I C104

    I C101R1

    04

    R604

    R156

    C275

    DZ204 R17

    2

    R195

    C117

    R103

    R401

    D104

    E409

    PTC1

    CN32

    BR1

    E407

    E404E283

    + E282+E281

    +

    E280

    RY1

    D601

    Q601

    C2

    C3

    C4C5

    C6

    C7

    C11

    C16

    C102

    C103

    C104C105

    C106

    C111

    C112

    C113

    C114

    C115

    C116

    C118

    C119

    C120

    C121

    C123

    C124

    C125

    C126

    C127

    C128

    C129C130

    C131

    C132

    C133

    C271C272

    C273

    C274

    C302

    C303

    C305

    C312C322

    C401C402

    C403

    C404

    C405

    C408

    C409

    C410

    C503

    C504

    C505

    C506

    C507

    C508

    C509

    C601

    C605

    C606

    C612

    C614

    C615

    CN7

    CN9

    CN31

    CN505

    D1D2

    D402

    D406

    DZ202

    DZ203

    DZ301DZ302DZ303DZ304

    DZ601

    E1

    E2

    E101

    E102

    E103

    E105

    E107

    E108

    E401

    E602

    I C1

    I C401I C403

    IC60

    1

    I C602

    IC60

    3

    LED101

    NTC2

    OSC101

    Q101

    R2

    R3

    R101

    R102

    R105

    R106

    R107

    R108

    R110

    R111R112

    R114

    R115

    R116

    R117

    R120

    R121

    R124R125

    R126R127

    R128

    R129

    R130

    R131

    R132

    R133

    R135

    R136

    R137

    R138

    R140R142

    R143

    R144

    R147R148R149

    R150

    R152

    R154R155

    R157

    R165

    R168

    R169

    R170

    R173

    R174

    R178

    R179

    R180R181

    R182

    R185R186

    R187

    R188

    R189

    R190

    R301

    R315

    R403

    R404

    R405

    R406

    R407

    R408

    R427

    R428

    R429

    R502

    R504R506R508

    R513

    R516

    R528

    R601

    R603

    R605

    R607

    R608R610R611

    R612

    R615

    R616

    R617

    R618

    R619

    R620

    R626

    RY2

    ZR1

    CN6

    D401

    D404

    Rdi

    I C102

    D602

    R171

    C611

    D101

    C101

    E106

    C1

    C520

    ZR3

    CN30

    CN29

    CN28

    C307

    C308

    C309

    C310

    C311R303

    R304R305

    R306R314

    R426

    C320

    C321

    C323

    C511 C512

    C513

    I C301

    R317

    R318

    R319

    R320

    R321

    R322

    R323

    R517

    R518

    R519

    R520

    R521

    R522

    R523

    CN50

    E206

    E605

    C134

    C314C316

    C318

    CN25

    D610

    R196

    RY3

    C624

    R602

    R623

    C110

    C122

    D407

    R316

    3W- 10m| ??¨ ¤1%

    R409

    R410

    R6063W

    -10m

    1%

    T401

    C107

    E109

    R175

    R176

    I PM301

    C319

    C306

    C413

    D103

    R621

    R421

    I C2

    C324

    R122

    R123

    R118

    C618

    R628

    CN15

    I C105

    R191

    RY3A

    ZR2

    RC1

    CN21

    R1

    C412

    E300

    E302

    E303

    C330

    C331

    C332

    C333C334

    connect t o t he t er mi nal208- 230V ACpower suppl y

    connect to earth

    CN60connect to 4-way valve

    when 4- way i s ON, out put 208- 230VAC

    connect t o compr essor heat er

    power suppl y

    CN17

    AC fan motor

    L low speed

    N ground

    H high speed

    CN21/CN22exhaust temp. sensor& pipetemp.sensor& room temp.sensor

    6 5 4 3 2 1

    TP T4 T3

    RT

    RT

    +5VDCRT

    +5VDC

    +5VDC

    connect to Electric Expansion Valve

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +1)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +2)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +3)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +4)-

    GND

    +12V

    DC

    +12V

    DC

    6 5 4 3 2 1

    connect to indoor unit communication

    HEAT2connect to chassis heaterwhen is on, 208-230VAC OUTPUT

    U

    V

    W

    10- 200VAC¡ ̄ ( r unni ng)

    0VAC ( st andby)

    connect t o t he DC compr essor

    Test PortConnect to PCcommunication

    EEPROM Programmer Port

    FUSE1 20A/250VAC

    U

    V

    W

    10- 200VAC¡ ̄ ( r unni ng)

    0VAC ( st andby)

    connect t o DC Mot or

    External driver motor

    slow flicker:standby(0.5Hz)quick flicker:error(2Hz)continuous light: normally running

    Connect to reactor

    IPM for

    compressor

    IGBT

    FRD

    when heater is ON, output 208-230V AC

    BR

    P

    N

  • For CH-24SPH-230VO,

    Suct i on

    Exhaust

    +

    17122200000309

    Hui Qi

    Test

    Port

    1

    1

    HEAT

    4- WAY

    W

    BLUE

    BLACK

    REDVU

    TP T3T4

    No

    NO

    NOYES

    Low- Fr e

    No

    Have

    YESHaveTemp- Pr o

    Rdi

    Ri pm

    11PMV

    44

    15V17V

    [ V1. 8] 2015- 01- 16

    7815

    22

    1

    34

    REACTOR

    311 TEST

    7805

    N- I N

    DC-F

    ANAC

    -FAN

    L- I N

    S

    KFR- 72W/ BP2- ( 311+0515+6061HD+PSS30S92F6-AG+6822+HEAT) . D. 13. WP2. 1

    12V 5V

    CN3DSA1

    K

    A

    K

    D5

    R18

    R46

    R107A

    R515A

    R316A

    R18A

    IC40

    3

    D4

    C21

    R54

    R55

    R68

    R69 R56

    R90

    C14

    J4

    R16

    R52

    J5

    +LE

    D1

    R78

    R142

    R141

    R155

    R154

    R153

    R152

    R151

    R150

    C3

    R108

    R107

    RC2

    RC4

    RC1

    RC3C1

    FUSE1

    65T 250V30A

    ZR1

    ZR2

    CN30

    R109

    R58 R6

    1

    R60

    R59

    C301

    C76

    C312

    R315

    C83

    C85

    C86

    C91

    R156R158

    R169

    R170

    R171

    R172

    I C34

    D11

    R157

    R159

    C310

    C306

    C308

    C311 C3

    07

    C309

    R110

    E305

    C302

    +DZ301Q3

    R75

    R84

    C103

    CN28

    CN29

    CN6-1

    CN6

    CN13

    CN12

    CN2

    CN8

    CN7

    CN22DR

    CN21DR

    R102

    J6

    PTC1

    CN414

    R127 C105

    +

    E5

    IPM2

    C501

    C503

    C507

    C508

    C509

    C510

    C511

    C512

    C517

    +DZ501 R501

    R502

    R503

    R504

    R505

    R506

    R509

    R510

    R511

    R512

    R513R5

    14

    R523

    C502

    C505

    +

    DZ502

    R515

    R522

    +

    DZ50

    4

    C504

    R316

    ~ ~

    I NAC-

    +

    R101R100

    R71

    C42

    CN20

    RY5

    CN16

    CN18

    NTC4

    C8

    C513

    C514

    C515

    C516

    R516R517

    R518R519

    R520

    R521

    C27

    I C7 24LC512

    3349

    17

    1

    IC9

    R53

    IC10

    1

    R160

    +

    E4

    +

    E3

    R83

    R82R81

    R80

    R79

    R50

    C47

    C20

    R322R321R3

    20Q2

    I C405

    +

    E10

    R120

    R167

    R166

    R32

    +

    E1

    R12 +LED3

    R412

    R413

    R414

    R415

    Rdi

    Ripm

    R13

    CN24

    R72

    R8

    R87R74

    J3

    I C17

    +

    E24

    D2

    R124

    C2

    J2 J1

    C77

    ACAC

    +-

    BR1

    C13

    D3

    R7

    RY3

    RY4

    RY2

    CN5

    R23

    R24

    R25

    R26

    R27

    C74

    C75

    RY1

    +

    E14 C9

    C17

    C18

    C19

    C23

    C24

    C26

    C32

    C33

    C35

    C36

    C37

    C39

    C43

    C48

    C49

    C52

    C65

    C67

    C78

    C87

    C89

    C90

    C92

    C147

    C153

    C25

    CN9

    CN23

    CN39

    +

    E17

    +

    E23

    +

    E28

    I C824LC08

    I C1224LC08

    I C14

    +

    LED2

    OSC1

    R5R30

    R31

    R40

    R41

    R42

    R48

    R49

    R62

    R64

    R65

    R66

    R70

    R73

    R76R77

    R86

    R92

    R97

    R161

    R162

    R163

    R164

    R165

    R176

    R177

    R419

    X1

    C58

    + +

    E405

    I C404

    R45

    Q1

    C15

    C22

    R21

    R22

    R28

    R29

    R33

    +

    E22

    R3R4

    R121

    C5

    +E6

    R10

    C28

    C4

    CN38

    I C10

    C79

    C80

    D7

    C6

    R148

    R63

    C506

    R507

    R508

    +

    E11

    R106C73

    I C21 PC817

    I C31PC817

    R175

    R178

    C409

    I C402

    C403

    I C11

    +

    E402

    D401

    C401 R40

    3

    C411

    C40

    C50

    D403

    R401

    R405

    R406

    R404

    +

    E404

    D402

    D404

    C408

    C402

    +

    E403R407

    R408

    C404

    C110

    +

    E409

    +E401

    R402

    C405

    10

    9

    7

    65

    4

    3

    1

    T401

    C406

    C407

    D13

    D14

    +

    E406

    +

    E407

    +

    E408

    +

    E502

    +

    E503

    +

    E504

    +

    DZ50

    3

    CN25

    R6R9

    CN60

    I C406

    I C407

    C7

    D1

    R1

    R137

    I C2PC851

    I C1PC817

    R2

    R126R125

    R123R122

    R119

    R118R117

    R15

    R14

    C99

    C98

    C97

    C96C95

    C94

    C93

    C66

    D20

    R17

    CN17

    CN10

    CN1

    C41

    R38

    C45

    C44

    R136

    R135

    R134

    R104

    D12

    D10

    C54

    +

    D8

    D9

    R57

    R20

    C242

    C243

    C244

    R89

    E2

    R67

    C84

    C10

    C11

    I C4

    C12

    C38

    R34

    R47R88

    IC32

    R39

    R35

    R36

    R19

    +

    DZ6

    R37

    C46

    C51

    C53

    CN19

    +DZ2

    +

    E27

    I C3 PC8

    17

    I C5PC817

    Q8

    R43

    R44

    R85

    R91

    R93

    R95R96

    R99

    D15

    R51

    +E410

    +

    E8

    C60

    C61

    E302

    E303

    E304 C62

    VN1

    VP1

    U

    P

    VUB

    U+

    W

    V+

    VW+

    U-

    VVB

    VWB

    FO

    W-V-

    NVNW

    NU

    VNCCIN

    I PM1

    +DZ304

    + DZ303

    + DZ302 C314

    C316

    C318

    C30

    C34

    C31

    ZR3

    ZR4

    C82

    L1

    R11

    R140

    CN27

    E301

    R168

    I GBT1

    connect to the DR moduleconnect to earth

    fuse 250V 30Aconnect to reactance

    290-330VDC standby210-300VDC running

    power supply 208-230V AC connect to the terminal

    connect to 4-way val vewhen 4-way is on, output 208-230V AC

    AC FAN mototr

    connect to compressor heaterwhen heater is on, output 208-230V AC

    1 low speed

    2 hign speed

    3 ground

    external drive motorconnect to DC motor0V AC standby10~200V AC’ running

    UVW

    connect to electric expansion valve

    6 5 4 3 2 1

    +12VDC

    +12VDC

    +12V DC pulse wave between( +4)-GND

    +12V DC pulse wave between( +3)-GND

    +12V DC pulse wave between( +2)-GND

    +12V DC pulse wave between( +1)-GND

    EEPROM Programmer Port

    reserve

    test port

    Connect to PCcommunication

    V

    U

    W

    connect to PC communication test port

    LED: status light(yellow)

    CN5/CN4 connect to chassis heaterwhen heater is on, output 208-230V AC

    connect to DC motor

    0V AC standby

    10~200V AC’ running

    bridge

    IGBT

    fast recovery diode(FRD)

    IPM for compressor

    IPM for DC FAN

    reserve

    P

    N

  • After power on, LED3(Green color) and LED2(Red color) will be flash if the unit has some problems.

    No. Problems LED3 (Green) LED2 (Red) IU display

    1 standby for normal O X 2 Operation normally X O 3 IPM malfunction or IGBT over-strong current protection ☆ X P0

    4 Over voltage or too low voltage protection O O P1

    5 EEPROM parameter error O ☆ E5

    6 Inverter compressor drive error X ☆ P4

    7 Inverter compressor drive error ☆ O P4

    8 Inverter compressor drive error ☆ ☆ P4

    O(light) X(off) ☆(2.5Hz flash)

  • For CH-S30FTXW-SV, CH-S36FTXW-SV,

    N L

    SHOW/ SW

    EARTH

    [ 1. 4] 2014. 06. 26

    EU- KFR105W/ BP3T5N1- 350S. D. 13. WP1- 1

    L- OUT

    N- OUT

    CONNECT TO INVERTER driver

    HIGH

    LOW

    T2B-E T2B-DT2B-C T2B-BT2B-A

    TP

    T4T3

    S- E

    S- D

    S- C

    S- B

    S- AFAN_OUT

    FAN_I NABCDE

    202302141206

    CN19

    CN10

    N

    CN9

    S

    CN44

    HEAT

    2

    CN43FAN

    CN42 C

    CN41

    C

    CN40

    HEAT

    1

    CN34

    CN33

    CN30

    CN29

    CN28

    CN27

    CN26

    CN22

    4-WA

    Y

    CN20CN18 CN17

    CN16

    CN14

    Comp

    Top

    CN12 CN11

    CN8

    CN6

    CN5

    CN4

    N

    CN3

    N

    CN2N- I N

    CN1L- I N

    CN23

    CN7

    CN13

    P- 1

    CN35

    N

    CN37FAN-L

    CN36

    FAN-

    H

    CN21

    Electric ExpansionValue B

    Electric ExpansionValue E

    Electric ExpansionValue D

    Electric ExpansionValue C

    Electric ExpansionValue A

    485communication

    testPortconnect to detector external drive DC fan

    motor input terminal

    external drive DC fanmotor ouput terminal

    current loopcommunication A

    current loopcommunication B

    current loopcommunication C

    current loopcommunication D

    current loopcommunication E

    digital display

    FuseT30A/250V

    connect to high and lowpressure sensor

    connect totrmp. sensor

    Fuse 5A/250V

    connect to earth

    CN23 reserve

    digital display button

    test reportconnect to detector

    CN43-5,CN43-1/CN41,CN42AC fan motor capacitorconnector

    CN43-4/CN37 CONNECT TOAC FAN MOTOR(LOW SPEED)

    CN43-3/CN36AC fan motor low speedconnectorCN43-2/CN35AV fan motor N phase

    current loopcommunication C

    Signal wire

    24VDC Pulse wave

    connect to the terminal

    connect to the terminal

    208-230V AC

    power supply

    room temp sensor

    pipe temp sensor

    (3.3V)

    (3.3V)

    high pressure sensor

    low pressure sensor

    Connect to the Indoor evap.pipeout temp. sensor

    T2B-A、T2B-B、T2B-C、T2B-D、T2B-E

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +1)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +2)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +3)-

    GND

    +12V

    DC

    puls

    e wa

    ve b

    etwe

    en (

    +4)-

    GND

    +12V

    DC

    +12V

    DC

    6 5 4 3 2 1

    when 4-way is ON, output 208-230VACconnect to the 4-WAY

    when heater is ON, output 208-230V AC

    connect to compressor heater

    CN44 LCN10 N

    CN40 LCN4 N

    CN22 LCN3 N

    connect to exhausttemp. sensor

    connect to the terminal

    208-230V AC

    external drive DC fanmotor connector

    T3

    T4

    electricheater1

    electricheater 2

  • IPM board,

    202302141237

    PFC-

    L2

    [ 1. 6] 2014. 10. 16

    EU- KFR105W/ BP2T3N1- 350( 767) . D. 13. MP2- 1

    PFC- L1 EARTH

    +

    CN55

    TO-M

    AIN

    W

    V

    U

    I PM2

    I PM1

    IC14

    24C0

    8

    CN54L-I N2

    N-IN

    2

    OUTF

    AN(D

    C)

    I C1

    CN53power suppl y

    connect t o t he t er mi nal208- 230V AC

    CN54CN51CN52

    PFC

    inductanceterminal

    CN58EATTH

    -+

    210- 300VDC ( Runni ng)

    CAPACI TOR Vol t age290- 330VDC ( st andby)

    CN55TO MAI N

    CN19

    connect to DC fan motor

    U

    V

    W

    10- 200VAC ( r unni ng)0VAC ( st andby)

    connect t o t he compr essor

    U

    V

    W10- 200VAC ( r unni ng)0VAC ( st andby)

  • 1.3 Diagnosis and Solution

    1.3.1 EEPROM parameter error diagnosis and solution(E0/F4) Error Code E0/F4

    Malfunction decision conditions

    Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.

    Supposed causes ● Installation mistake ● PCB faulty

    Trouble shooting:

    Yes

    Replace the indoor/outdoor main PCB.

    Power off, then restart the unit 2 minutes later.

    EEPROM: a read-only memory whose contents can be erased and reprogrammed using a pulsed voltage. For the location of EEPROM chip, please refer to the below photos.

    Indoor PCB Outdoor PCB

    Note: The two photos above are only for reference, it’s may be not same totally with the ones on your side.

  • 1.3.2 Indoor / outdoor unit’s communication diagnosis and solution(E1) Error Code E1

    Malfunction decision conditions

    Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition happens four times continuously.

    Supposed causes ● Wiring mistake ● Indoor or outdoor PCB faulty

    Trouble shooting:

    Measure Vs. Is the voltage moving alternately between -25V to 25V?Measure Vs. Is the voltage moving alternately between -25V to 25V?

    Yes

    Power off, then restart the unit 2 minutes later. Is the error extinguished?

    Power off, then restart the unit 2 minutes later. Is the error extinguished?

    No

    Replace the outdoor main PCB.Power on. Is the error

    extinguished?

    Replace the outdoor main PCB.Power on. Is the error

    extinguished?

    Check the outdoor wiring connection。Is the wiring correctly?

    Check the outdoor wiring connection。Is the wiring correctly?

    Replace the indoor main PCB.Power on. Is the error

    extinguished?

    Replace the indoor main PCB.Power on. Is the error

    extinguished?

    Yes

    Replace the outdoor main PCB.Replace the outdoor main PCB.

    No

    Replace the indoor main PCB.Replace the indoor main PCB.

    No

    Check the indoor wiring connection。Is the wiring correctly?

    Check the indoor wiring connection。Is the wiring correctly?

    Yes

    No

    Check whether reactor is normal?Check whether reactor is normal?

    Yes

    Replace the reactorReplace the reactor No

  • Remark: Use a multimeter to test the DC voltage between 2 port and 3 port of outdoor unit. The red pin of multimeter connects with 2 port while the black pin is for 3 port. When AC is normal running, the voltage will move alternately between -25V to 25V. If the outdoor unit has malfunction, the voltage will move alternately with positive value. While if the indoor unit has malfunction, the voltage will be a certain value.

    Remark: Use a multimeter to test the resistance of the reactor which does not connect with capacitor. The normal value should be around zero ohm. Otherwise, the reactor must have malfunction.

  • 1.3.3 Zero crossing detection error diagnosis and solution (E2) Error Code E2

    Malfunction decision conditions

    When PCB does not receive zero crossing signal feedback for 4 minutes or the zero crossing signal time interval is abnormal.

    Supposed causes ● Connection mistake ● PCB faulty

    Trouble shooting:

    Check if the connections and power supply is normal?

    Correct the connections. Turn on the unit when the power supply is good.No

    Yes

    Indoor main PCB is defective. Replace indoor

    main PCB.

  • 1.3.4 Fan speed has been out of control diagnosis and solution(E3) Error Code E3/F5

    Malfunction decision conditions

    When indoor fan speed keeps too low (300RPM) for certain time, the unit will stop and the LED will display the failure.

    Supposed causes ● Wiring mistake ● Fan ass’y faulty ● Fan motor faulty ● PCB faulty

    Trouble shooting:

    Power off, then restart the unit 2 minutes later

    Shut off the power supply, Rotate the fan by hand.

    The unit operates normally.

    Find out the cause and have it solved

    Check the wiring of fan motor

    No

    Yes

    No

    Correct the connections.No

    NoReplace the fan motor

    Yes

    Yes

    Measure the voltage for the fan motor from the main

    PCB refer to the Appendix 1

    Yes

    Replace the main PCBNo

  • Index 1:

    1:Indoor or Outdoor DC Fan Motor(control chip is in fan motor)

    Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor

    connector. If the value of the voltage is not in the range showing in below table, the PCB must has

    problems and need to be replaced.

    DC motor voltage input and output(voltage: 220-240V~)

    NO. Color Signal Voltage 1 Red Vs/Vm 280V~380V 2 --- --- --- 3 Black GND 0V 4 White Vcc 14-17.5V 5 Yellow Vsp 0~5.6V 6 Blue FG 14-17.5V

    DC motor voltage input and output(voltage :115V~)

    NO. Color Signal Voltage 1 Red Vs/Vm 140V~190V 2 --- --- --- 3 Black GND 0V 4 White Vcc 14-17.5V 5 Yellow Vsp 0~5.6V 6 Blue FG 14-17.5V

    2. Outdoor DC Fan Motor (control chip is in outdoor PCB)

    Power on ,and check if the fan can run normally, if the fan can run normally, the PCB must has

    problems and need to be replaced, If the fan can’t run normally, measure the resistance of each two

    pins. If the resistance is not equal to each other, the fan motor must have problems and need to be

    replaced, otherwise the PCB must has problems and need to be replaced.

    3. Indoor AC Fan Motor

    Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,

    measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power

    supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.

  • 1.3.5 Open circuit or short circuit of temperature sensor diagnosis and solution(E5) Error Code E4/E5/F1/F2/F3

    Malfunction decision conditions

    If the sampling voltage is lower than 0.06V or higher than 4.94V, the LED will display the failure.

    Supposed causes ● Wiring mistake ● Sensor faulty ● PCB faulty

    Trouble shooting:

    Check the connection between temperature

    sensor and PCB.Correct the connectionNo

    Yes

    Replace indoor or outdoor main PCB

    Measure the resistance value of the sensor Repalce the sensorNo

    Yes

  • 1.3.6 Refrigerant Leakage Detection diagnosis and solution(EC) Error Code EC

    Malfunction decision conditions

    Define the evaporator coil temp.T2 of the compressor just starts running as Tcool. In the beginning 5 minutes after the compressor starts up, if T2 <Tcool-2°C(Tcool-35.6°F) does not keep continuous 4 seconds and this situation happens 3 times, the display area will show “EC” and AC will turn off.

    Supposed causes ● T2 sensor faulty ● Indoor PCB faulty ● System problems, such as leakage or blocking.

    Trouble shooting:

    Is there cool air blowing out from indoor air outlet?

    Yes

    Yes

    Check if T2 sensor is well fixed. Correct the installation or replace T2 sensor. Does the problem remain again?

    No

    Is there any leakage? Especially the connection parts, such as the gas valve and the liquid valve.

    No

    Shut off the power supply and turn it on 2 minutes later. Is it still displaying the error code?

    Replace indoor PCB.

    Yes

    Repair the leakage and recharge the refrigerant.

    Yes

    Clear the blocking.

    Yes

    Is there any block i n g ? (Such as the capillary or the welded points of the pipes.)

  • 1.3.6 Overload current protection diagnosis and solution(F0) Error Code F0

    Malfunction decision conditions

    An abnormal current rise is detected by checking the specified current detection circuit.

    Supposed causes ● Power supply problems. ● System blockage ● PCB faulty ● Wiring mistake ● Compressor malfunction

    Trouble shooting:

    Check the power supply. Is it normal?

    Check the connections and wires .Is it well connection?

    Stop the unit. Check the power supplyNo

    Yes

    No Correct the connections or replace the wires.

    Yes

    Replace the outdoor main PCB

    Yes

    Check the reactor .Is it normal? No Replace the reactor

    Is there any blocking?

    No

    Yes Clear the blockage

    Check the compressor resistance values refer to the

    [Compressor checking]. Is it normal?

    Yes

    No Replace the compressor

  • 1.3.7 IPM malfunction or IGBT over-strong current protection diagnosis and solution(P0) Error Code P0

    Malfunction decision conditions

    When the voltage signal that IPM send to compressor drive chip is abnormal, the display LED will show “P0” and AC will turn off.

    Supposed causes ● Wiring mistake ● IPM malfunction ● Outdoor fan ass’y faulty ● Compressor malfunction ● Outdoor PCB faulty

    Trouble shooting: For 9K~24K:

    Check if the wiring between main PCB and compressor . If the wires and connectors are broken?

    Correct the connection or replace the wires and connectors.Yes

    No

    IPM continuity check. Check if the IPM terminal resistance values are uniform.

    Replace the IPM board or replace the main PCB if the IPM board and main

    PCB are integrated together.No

    Check if the outdoor fan runs properly or the outdoor unit

    ventilation is good.

    Yes

    No Please refer to the solution of 【Fan Speed Has Been Out Of Control】malfunction

    Yes

    Check if the compressor resistance values are uniform . No Replace the compressor.

    Yes

    Replace the outdoor main PCB if the main PCB and IPM are separate.

  • For example:

    P-U

    P-V

    Note: The photos below are only for reference, it’s may be not same totally with the ones on your side.

  • P-W

    N-U

  • N-V

    N-W

  • For 30K~36K: At first test the resistance between every two ports of U, V, W of IPM and P, N. If any result of them is 0 or close to 0, the IPM is defective. Otherwise, please follow the procedure below:

    Yes

    Check whether the power voltage is normal.

    Check whether the power voltage is normal.

    Measure whether outdoor terminal voltage is normal?

    Measure whether outdoor terminal voltage is normal?

    Restart the unit when the power supply gets normal

    Restart the unit when the power supply gets normalNo

    Yes

    No Reconnect it wellReconnect it well

    Yes

    Measure whether the voltage between L and N is normal?Measure whether the voltage between L and N is normal?

    Yes

    Measure whether input voltage of bridge rectifier is normal?

    Measure whether input voltage of bridge rectifier is normal?

    No

    No

    Check the wiring of power wires well or

    correctly

    Check the wiring of power wires well or

    correctly

    Reconnect it wellReconnect it wellCheck the wiring of L and N well or correctlyCheck the wiring of L and N well or correctly

    Reconnect it wellReconnect it well Check the wiring of

    bridge rectifier well or correctly

    Check the wiring of bridge rectifier well or

    correctly

    No

    Yes

    Replace the PFC module(If has)Replace the PFC module(If has)

    No

    Measure whether the voltage between P and N is normal

    refer to the Appendix 4?

    Measure whether the voltage between P and N is normal

    refer to the Appendix 4?Replace the bridge rectifierReplace the bridge rectifierNoCheck whether bridge

    rectifier is normalCheck whether bridge

    rectifier is normal

    Check the wiring of reactor or inductance

    Check the wiring of reactor or inductance Reconnect the wiring Reconnect the wiring No

    Check whether reactor or inductance is normal

    Check whether reactor or inductance is normal

    Yes

    Replace reactor or inductance

    Replace reactor or inductanceNo

    Check whether the connecting wire between main board and the

    IPM board is connected tightly

    Check whether the connecting wire between main board and the

    IPM board is connected tightlyReconnect it wellReconnect it wellNo

    Check if the outdoor unit ventilation is good

    Check if the outdoor unit ventilation is good

    Yes

    Make the outdoor unit ventilate wellMake the outdoor unit ventilate well

    Check whether the refrigerant system is okCheck whether the refrigerant system is ok

    No

    Check if the outdoor fan runs properly

    Check if the outdoor fan runs properly

    please refer to the solution of [fan speed has been out of control malfunction] . Find out the cause and have it solved.

    please refer to the solution of [fan speed has been out of control malfunction] . Find out the cause and have it solved.

    No

    Yes

    No

    Yes

    Yes

    Check the compress is normal

    Check the compress is normal

    Yes

    Replace the compressorReplace the compressorNo

    Replace IPM board Replace IPM board

    Replace the outdoor main PCB Replace the outdoor main PCB

    No

    Check whether the connecting wire of the compressor is

    connected correctly or tightly

    Check whether the connecting wire of the compressor is

    connected correctly or tightlyReconnect it wellReconnect it wellNo

    Yes

    Yes

  • 1.3.8 Over voltage or too low voltage protection diagnosis and solution(P1) Error Code P1

    Malfunction decision conditions

    An abnormal voltage rise or drop is detected by checking the specified voltage detection circuit.

    Supposed causes ● Power supply problems. ● System leakage or block ● PCB faulty

    Trouble shooting:

    Check the power supply

    Check the connections and wires

    Stop the unitNo

    Yes

    No Correct the connections or replace the wires.

    Yes

    Replace the reactor

    Yes

    No Replace the IPM board Check the voltage between P

    and N

    Check the reactor

    Yes

    No Replace outdoor main PCB

    Remark: Measure the DC voltage between P and N port. The normal value should be around 310V.

    P N

  • 1.3.9 High temperature protection of IPM module or compressor top diagnosis and solution(P2) Error Code P2

    Malfunction decision conditions

    If the sampling voltage is not 5V, the LED will display the failure.

    Supposed causes ● Installation mistake ● Power supply problems. ● System leakage or block ● PCB faulty

    Trouble shooting: For 18K,24K,

    Yes

    Tighten the screws and apply silicon grease.

    Tighten the screws and apply silicon grease.

    Replace the outdoor control PCB.Replace the outdoor control PCB.

    No

    Check if the Fastening screws on the PCB and IPM radiator

    are fixed tightly.

    For other models,

    Check if the air flow system of indoor and outdoor units

    are obstructed?

    Clear up the air inlet and outlet or the heat exchanger of indoor and outdoor units.Yes

    No

    Yes

    Yes

    Turn off the power supply and turn it on 10 minutes later.

    Check if the temperature of compressor Top

    Is more than 90℃?No

    Check if the refrigerant system

    is normal?

    Repair the refrigerant system .Replace the outdoor control PCB.

    Yes

    Check if all the connection, especially the connection of OLP (Over Load

    Protector) sensor is good.Correct the connection.No

    Measure the resistance between the two ports of the OLP. Is it zero?

    Yes

    Replace the OLP.No

    Replace the outdoor control PCB.YesNo

  • 1.3.10 Inverter compressor drive error diagnosis and solution(P4) Error Code P4

    Malfunction decision conditions

    An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on.

    Supposed causes ● Wiring mistake ● IPM malfunction ● Outdoor fan ass’y faulty ● Compressor malfunction ● Outdoor PCB faulty

    Trouble shooting: For 9K~24K:

    Check if the wiring between main PCB and compressor connected well?

    Correct the connection or replace the wires and

    connectors.No

    Check if the IPM installed correctly.Correct the installation, tighten the screws and apply silicon grease.

    No

    IPM continuity check. Check if the IPM terminal resistance values are uniform.

    Yes

    Replace the IPM board or replace the main PCB if the IPM board and main PCB are integrated together.

    No

    Check if the outdoor fan runs properly or the outdoor unit

    ventilation is good.

    Yes

    NoPlease refer to the solution of 【Fan Speed Has Been Out Of Control】

    malfunction

    Yes

    Check if the compressor resistance values are uniform . No Replace the compressor.

    Yes

    Replace the outdoor main PCB if the main PCB and IPM are separate.

    Check the reactor or Inductance .Is it normal? No

    Replace the reactor or Inductance

    Yes

    Yes

    IPM continuity check

    Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital tester to measure the resistance between P and UVWN; UVW and N.

  • Digital tester Normal resistance value Digital tester Normal resistance value (+)Red (-)Black

    ∞ (Several MΩ)

    (+)Red (-)Black

    ∞ (Several MΩ) P

    N U

    N U V V W W (+)Red

    For 30K~36K: At first test the resistance between every two ports of U, V, W of IPM and P, N. If any result of them is 0 or close to 0, the IPM is defective. Otherwise, please follow the procedure below:

    Yes

    Check whether the power voltage is normal.

    Check whether the power voltage is normal.

    Measure whether outdoor terminal voltage is normal?

    Measure whether outdoor terminal voltage is normal?

    Restart the unit when the power supply gets normal

    Restart the unit when the power supply gets normalNo

    Yes

    No Reconnect it wellReconnect it well

    Yes

    Measure whether the voltage between L and N is normal?Measure whether the voltage between L and N is normal?

    Yes

    Measure whether input voltage of bridge rectifier is normal?

    Measure whether input voltage of bridge rectifier is normal?

    No

    No

    Check the wiring of power wires well or

    correctly

    Check the wiring of power wires well or

    correctly

    Reconnect it wellReconnect it wellCheck the wiring of L and N well or correctlyCheck the wiring of L and N well or correctly

    Reconnect it wellReconnect it well Check the wiring of

    bridge rectifier well or correctly

    Check the wiring of bridge rectifier well or

    correctly

    No

    Yes

    Replace the PFC module(If has)Replace the PFC module(If has)

    No

    Measure whether the voltage between P and N is normal

    refer to the Appendix 4?

    Measure whether the voltage between P and N is normal

    refer to the Appendix 4?Replace the bridge rectifierReplace the bridge rectifierNoCheck whether bridge

    rectifier is normalCheck whether bridge

    rectifier is normal

    Check the wiring of reactor or inductance

    Check the wiring of reactor or inductance Reconnect the wiring Reconnect the wiring No

    Check whether reactor or inductance is normal

    Check whether reactor or inductance is normal

    Yes

    Replace reactor or inductance

    Replace reactor or inductanceNo

    Check whether the connecting wire between main board and the

    IPM board is connected tightly

    Check whether the connecting wire between main board and the

    IPM board is connected tightlyReconnect it wellReconnect it wellNo

    Check if the outdoor unit ventilation is good

    Check if the outdoor unit ventilation is good

    Yes

    Make the outdoor unit ventilate wellMake the outdoor unit ventilate well

    Check whether the refrigerant system is okCheck whether the refrigerant system is ok

    No

    Check if the outdoor fan runs properly

    Check if the outdoor fan runs properly

    please refer to the solution of [fan speed has been out of control malfunction] . Find out the cause and have it solved.

    please refer to the solution of [fan speed has been out of control malfunction] . Find out the cause and have it solved.

    No

    Yes

    No

    Yes

    Yes

    Check the compress is normal

    Check the compress is normal

    Yes

    Replace the compressorReplace the compressorNo

    Replace IPM board Replace IPM board

    Replace the outdoor main PCB Replace the outdoor main PCB

    No

    Check whether the connecting wire of the compressor is

    connected correctly or tightly

    Check whether the connecting wire of the compressor is

    connected correctly or tightlyReconnect it wellReconnect it wellNo

    Yes

    Yes

  • 1.3.11 Low pressure protection diagnosis and solution(P6) Error Code P6

    Malfunction decision conditions

    When the pressure of system reach a certain value, the low pressure protector will switch off. After the pressure resume to normal ,the protection code will disappear.

    Supposed causes ● Wiring mistake ● Pressure protector faulty ● Fan motor faulty ● PCB faulty ● System problems.

    Trouble shooting:

    Whether the wiring between the low pressure protector and main control board is connected well or

    correctly

    Whether the wiring between the low pressure protector and main control board is connected well or

    correctly

    Method: Disconnect the plug. Measure the

    resistance of the low pressure protector. If the

    protector is normal the value is o

    Method: Disconnect the plug. Measure the

    resistance of the low pressure protector. If the

    protector is normal the value is o

    Yes

    Yes

    Connect it wellConnect it well

    Replace outdoor main boardReplace outdoor main board

    No

    Replace low pressure protectorReplace low pressure protectorNo

    Whether the low pressure protector

    is broken

    Whether the low pressure protector

    is broken

    Check whether the outdoor ambient temperature is too

    low

    Check whether the outdoor ambient temperature is too

    low

    No

    Stop the unit Stop the unit Yes

    Open fully valve core of high pressure valve

    Open fully valve core of high pressure valveNo

    Check whether valve core of high pressure valve is

    opened

    Check whether valve core of high pressure valve is

    opened

    Check if the indoor fan runs properly in cooling mode

    Check if the indoor fan runs properly in cooling mode

    please refer to the solution of [fan speed has been out of control

    malfunction]. Find out the cause and have it solved.

    please refer to the solution of [fan speed has been out of control

    malfunction]. Find out the cause and have it solved.

    No

    Yes

    Yes

    No

    Check whether the refrigerant system is ok

    Check whether the refrigerant system is ok

    Refrigerant is not enough add the refrigerant

    Refrigerant is not enough add the refrigerant

    No

  • Main parts check 1. Temperature sensor checking

    Disconnect the temperature sensor from PCB, measure the resistance value with a tester.

    Temperature sensors. Room temp.(T1) sensor, Indoor coil temp.(T2) sensor, Outdoor coil temp.(T3) sensor, Outdoor ambient temp.(T4) sensor, Compressor discharge temp.(TP) sensor. Measure the resistance value of each winding by using the multi-meter.

  • Appendix 1 Temperature Sensor Resistance Value Table for T1,T2,T3,T4 (°C--K) °C °F K Ohm °C °F K Ohm °C °F K Ohm °C °F K Ohm -20 -4 115.266 20 68 12.6431 60 140 2.35774 100 212 0.62973

    -19 -2 108.146 21 70 12.0561 61 142 2.27249 101 214 0.61148

    -18 0 101.517 22 72 11.5 62 144 2.19073 102 216 0.59386

    -17 1 96.3423 23 73 10.9731 63 145 2.11241 103 217 0.57683

    -16 3 89.5865 24 75 10.4736 64 147 2.03732 104 219 0.56038

    -15 5 84.219 25 77 10 65 149 1.96532 105 221 0.54448

    -14 7 79.311 26 79 9.55074 66 151 1.89627 106 223 0.52912

    -13 9 74.536 27 81 9.12445 67 153 1.83003 107 225 0.51426

    -12 10 70.1698 28 82 8.71983 68 154 1.76647 108 226 0.49989

    -11 12 66.0898 29 84 8.33566 69 156 1.70547 109 228 0.486

    -10 14 62.2756 30 86 7.97078 70 158 1.64691 110 230 0.47256

    -9 16 58.7079 31 88 7.62411 71 160 1.59068 111 232 0.45957

    -8 18 56.3694 32 90 7.29464 72 162 1.53668 112 234 0.44699

    -7 19 52.2438 33 91 6.98142 73 163 1.48481 113 235 0.43482

    -6 21 49.3161 34 93 6.68355 74 165 1.43498 114 237 0.42304

    -5 23 46.5725 35 95 6.40021 75 167 1.38703 115 239 0.41164

    -4 25 44 36 97 6.13059 76 169 1.34105 116 241 0.4006

    -3 27 41.5878 37 99 5.87359 77 171 1.29078 117 243 0.38991

    -2 28 39.8239 38 100 5.62961 78 172 1.25423 118 244 0.37956

    -1 30 37.1988 39 102 5.39689 79 174 1.2133 119 246 0.36954

    0 32 35.2024 40 104 5.17519 80 176 1.17393 120 248 0.35982

    1 34 33.3269 41 106 4.96392 81 178 1.13604 121 250 0.35042

    2 36 31.5635 42 108 4.76253 82 180 1.09958 122 252 0.3413

    3 37 29.9058 43 109 4.5705 83 181 1.06448 123 253 0.33246

    4 39 28.3459 44 111 4.38736 84 183 1.03069 124 255 0.3239

    5 41 26.8778 45 113 4.21263 85 185 0.99815 125 257 0.31559

    6 43 25.4954 46 115 4.04589 86 187 0.96681 126 259 0.30754

    7 45 24.1932 47 117 3.88673 87 189 0.93662 127 261 0.29974

    8 46 22.5662 48 118 3.73476 88 190 0.90753 128 262 0.29216

    9 48 21.8094 49 120 3.58962 89 192 0.8795 129 264 0.28482

    10 50 20.7184 50 122 3.45097 90 194 0.85248 130 266 0.2777

    11 52 19.6891 51 124 3.31847 91 196 0.82643 131 268 0.27078

    12 54 18.7177 52 126 3.19183 92 198 0.80132 132 270 0.26408

    13 55 17.8005 53 127 3.07075 93 199 0.77709 133 271 0.25757

    14 57 16.9341 54 129 2.95896 94 201 0.75373 134 273 0.25125

    15 59 16.1156 55 131 2.84421 95 203 0.73119 135 275 0.24512

    16 61 15.3418 56 133 2.73823 96 205 0.70944 136 277 0.23916

    17 63 14.6181 57 135 2.63682 97 207 0.68844 137 279 0.23338

    18 64 13.918 58 136 2.53973 98 208 0.66818 138 280 0.22776

    19 66 13.2631 59 138 2.44677 99 210 0.64862 139 282 0.22231

  • Appendix 2 Temperature Sensor Resistance Value Table for TP (°C --K) °C °F K Ohm °C °F K Ohm °C °F K Ohm °C °F K Ohm

    -20 -4 542.7 20 68 68.66 60 140 13.59 100 212 3.702

    -19 -2 511.9 21 70 65.62 61 142 13.11 101 214 3.595

    -18 0 483 22 72 62.73 62 144 12.65 102 216 3.492

    -17 1 455.9 23 73 59.98 63 145 12.21 103 217 3.392

    -16 3 430.5 24 75 57.37 64 147 11.79 104 219 3.296

    -15 5 406.7 25 77 54.89 65 149 11.38 105 221 3.203

    -14 7 384.3 26 79 52.53 66 151 10.99 106 223 3.113

    -13 9 363.3 27 81 50.28 67 153 10.61 107 225 3.025

    -12 10 343.6 28 82 48.14 68 154 10.25 108 226 2.941

    -11 12 325.1 29 84 46.11 69 156 9.902 109 228 2.86

    -10 14 307.7 30 86 44.17 70 158 9.569 110 230 2.781

    -9 16 291.3 31 88 42.33 71 160 9.248 111 232 2.704

    -8 18 275.9 32 90 40.57 72 162 8.94 112 234 2.63

    -7 19 261.4 33 91 38.89 73 163 8.643 113 235 2.559

    -6 21 247.8 34 93 37.3 74 165 8.358 114 237 2.489

    -5 23 234.9 35 95 35.78 75 167 8.084 115 239 2.422

    -4 25 222.8 36 97 34.32 76 169 7.82 116 241 2.357

    -3 27 211.4 37 99 32.94 77 171 7.566 117 243 2.294

    -2 28 200.7 38 100 31.62 78 172 7.321 118 244 2.233

    -1 30 190.5 39 102 30.36 79 174 7.086 119 246 2.174

    0 32 180.9 40 104 29.15 80 176 6.859 120 248 2.117

    1 34 171.9 41 106 28 81 178 6.641 121 250 2.061

    2 36 163.3 42 108 26.9 82 180 6.43 122 252 2.007

    3 37 155.2 43 109 25.86 83 181 6.228 123 253 1.955

    4 39 147.6 44 111 24.85 84 183 6.033 124 255 1.905

    5 41 140.4 45 113 23.89 85 185 5.844 125 257 1.856

    6 43 133.5 46 115 22.89 86 187 5.663 126 259 1.808

    7 45 127.1 47 117 22.1 87 189 5.488 127 261 1.762

    8 46 121 48 118 21.26 88 190 5.32 128 262 1.717

    9 48 115.2 49 120 20.46 89 192 5.157 129 264 1.674

    10 50 109.8 50 122 19.69 90 194 5 130 266 1.632

    11 52 104.6 51 124 18.96 91 196 4.849

    12 54 99.69 52 126 18.26 92 198 4.703

    13 55 95.05 53 127 17.58 93 199 4.562

    14 57 90.66 54 129 16.94 94 201 4.426

    15 59 86.49 55 131 16.32 95 203 4.294

    16 61 82.54 56 133 15.73 96 205 4.167

    17 63 78.79 57 135 15.16 97 207 4.045

    18 64 75.24 58 136 14.62 98 208 3.927

    19 66 71.86 59 138 14.09 99 210 3.812

  • Appendix 3:

    ΔT(℉) =9ΔT(℃)

    5 °C °F °C °F °C °F °C °F °C °F

    -5 23 21 69.8 51 123.8 82 179.6 113 235.4 -4 24.8 22 71.6 52 125.6 83 181.4 114 237.2 -3 26.6 23 73.4 53 127.4 84 183.2 115 239 -2 28.4 24 75.2 54 129.2 85 185 116 240.8 -1 30.2 25 77 55 131 86 186.8 117 242.6 0 32 25.5 77.9 56 132.8 87 188.6 118 244.4

    0.5 32.9 26 78.8 57 134.6 88 190.4 119 246.2 1 33.8 27 80.6 58 136.4 89 192.2 120 248

    1.5 34.7 28 82.4 59 138.2 90 194 121 249.8 2 35.6 29 84.2 60 140 91 195.8 122 251.6

    2.5 36.5 30 86 61 141.8 92 197.6 123 253.4 3 37.4 31 87.8 62 143.6 93 199.4 124 255.2

    3.5 38.3 32 89.6 63 145.4 94 201.2 125 257 4 39.2 33 91.4 64 147.2 95 203 126 258.8

    4.5 40.1 34 93.2 65 149 96 204.8 127 260.6 5 41 35 95 66 150.8 97 206.6 128 262.4 6 42.8 36 96.8 67 152.6 98 208.4 129 264.2 7 44.6 37 98.6 68 154.4 99 210.2 130 266 8 46.4 38 100.4 69 156.2 100 212 131 267.8 9 48.2 39 102.2 70 158 101 213.8 132 269.6

    10 50 40 104 71 159.8 102 215.6 133 271.4 11 51.8 41 105.8 72 161.6 103 217.4 134 273.2 12 53.6 42 107.6 73 163.4 104 219.2 135 275 13 55.4 43 109.4 74 165.2 105 221 136 276.8 14 57.2 44 111.2 75 167 106 222.8 137 278.6 15 59 45 113 76 168.8 107 224.6 138 280.4 16 60.8 46 114.8 77 170.6 108 226.4 139 282.2 17 62.6 47 116.6 78 172.4 109 228.2 140 284 18 64.4 48 118.4 79 174.2 110 230 141 285.8 19 66.2 49 120.2 80 176 111 231.8 142 287.6 20 68 50 122 81 177.8 112 233.6 143 289.4

  • Appendix 4

    1. Normal voltage of P and N

    208-240V(1-phase,3-phase) 380-420V(3-phase) In standby

    around 310VDC around 530VDC In operation

    With passive PFC module

    With partial active PFC

    module

    With fully active PFC module /

    >200VDC >310VDC >370VDC >450VDC

  • 2. Compressor checking Measure the resistance value of each winding by using the tester.

    Position Resistance Value

    ASN98D22UFZ ASM135D23UFZ ATF235D22UMT ATF250D22UMT Blue - Red

    1.57Ω

    1.75 Ω

    0.75 Ω

    0.75 Ω

    Blue - Black

    Red - Blue

  • 3. Fan Motor Measure the resistance value of each winding by using the tester.

    Model YKT-32-6-202L

    YKT-32-6-3L

    YKT-48-6-206

    YKT-63-6-200L

    Brand Tongde Welling Welling Welling Black –

    Red Main

    Ω 86 213 152 88.5

    Blue –Black

    AUX

    Ω 64 156 142 138

  • 4. Pressure On Service Port Cooling chart:

    °F(°C) ODT IDT 75

    (23.89) 85

    (29.44) 95

    (35) 105

    (40.56) 115

    (46.11) BAR 70/59 8.2 7.8 8.1 8.6 10.1 BAR 75/63 8.6 8.3 8.7 9.1 10.7 BAR 80/67 9.3 8.9 9.1 9.6 11.2

    °F(°C) ODT IDT

    75 (23.89)

    85 (29.44)

    95 (35)

    105 (40.56)

    115 (46.11)

    PSI 70/59 119 113 117 125 147 PSI 75/63 124 120 126 132 155 PSI 80/67 135 129 132 140 162

    °F(°C) ODT IDT

    75 (23.89)

    85 (29.44)

    95 (35)

    105 (40.56)

    115 (46.11)

    MPA 70/59 0.82 0.78 0.81 0.86 1.01 MPA 75/63 0.86 0.83 0.87 0.91 1.07 MPA 80/67 0.93 0.89 0.91 0.96 1.12

    0,0

    2,0

    4,0

    6,0

    8,0

    10,0

    12,0

    75 (23.89) 85 (29.44) 95 (35) 105 (40.56) 115 (46.11)

    70/59

    75/63

    80/67

  • Heating Chart: °F (°C)

    ODT IDT

    57/53 (13.89/11.67)

    47/43 (8.33/6.11)

    37/33 (2.78/0.56)

    27/23 (-2.78/-5)

    17/13 (-8.33/-10.56)

    BAR 55 30.3 28.5 25.3 22.8 20.8 BAR 65 32.5 30.0 26.6 25.4 23.3 BAR 75 33.8 31.5 27.8 26.3 24.9

    °F (°C)

    ODT IDT

    57/53 (13.89/11.67)

    47/43 (8.33/6.11)

    37/33 (2.78/0.56)

    27/23 (-2.78/-5)

    17/13 (-8.33/-10.56)

    PSI 55 439 413 367 330 302 PSI 65 471 435 386 368 339 PSI 75 489 457 403 381 362

    °F (°C)

    ODT IDT

    57/53 (13.89/11.67)

    47/43 (8.33/6.11)

    37/33 (2.78/0.56)

    27/23 (-2.78/-5)

    17/13 (-8.33/-10.56)

    MPA 55 3.03 2.85 2.53 2.28 2.08 MPA 65 3.25 3.00 2.66 2.54 2.33 MPA 75 3.38 3.15 2.78 2.63 2.49

    2. Disassembly Instructions Note: This part is for reference, the photos may have slight difference with your machine.

    2.1 Indoor unit

    No. Parts name Procedures Remarks

    0,0

    5,0

    10,0

    15,0

    20,0

    25,0

    30,0

    35,0

    40,0

    57/53 (13.89/11.67)

    47/43 (8.33/6.11)

    37/33 (2.78/0.56)

    27/23(-2.78/-5)

    17/13(-8.33/-10.56)

    55

    65

    75

  • 1 Front panel How to remove the front panel.

    1) Pull the below side of

    the panel toward you and

    remove screw of the cover.

    2) Release the connector of

    the display ass’y.

    3) Release the two clips and

    then remove the panel.

    4) Remove the filter and the

    horizontal louver.

    5) Remove the three screws

    and then remove the panel

    ass’y.

    ①1 screw

  • 2 Electrical parts

    How to remove the electrical

    parts.

    1) Remove the front

    panel from procedure 1.

    2) Pull out the room temp.

    sensor (T1). Remove the two

    screws for the ground

    connection.

    3) Remove the fixing screw.

    4) Pull out the coil temp.

    sensor.

    5) From the side direction,

    open the electronic control box

    cover fixing by clips. Pull out

    the fan motor connector and

    swing motor connector. Then

    remove the electronic control

    box.

    1.1 Indoor Unit Error Display1.2 Outdoor unit error display(TBD)1.3 Diagnosis and Solution2. Disassembly Instructions2.1 Indoor unit