15
Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

Embed Size (px)

Citation preview

Page 1: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

Spare parts listseries Inovia Cond Plus

Edition 11/2016

*1756227250*17562.2725.0 REV1

29/11 2016

N

Page 2: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

Spare parts list

1 REPLACEMENT PARTS CATALOGUE

This catalogue includes all the replacement parts required for themain-tenance and service of boilers. This edition of the catalogue superse-des all previous editions.

2 MODELS AND SPECIFICATIONS

Boilers differ in basic characteristics:

2.1 Maximum useful heating power during operation as abuilding heat source

Themodels are available with different maximum useful heating powerwhen used as a building heat source. Each of thesemodels is identifiedby its own model number:

Models 20 (20kW), 25 (25kW)

2.2 Maximum useful domestic hot water power

The models are available with different maximum useful domestic hotwater power when used as the heating of domestic hot water. Each ofthese models is identified by its own model number:

Models 25 (25kW), 30 (30kW)

2.3 Mixed---type operation/operation as a building heatsource only

Mixed--- type boilers are used to heat water for use in a building heatingsystem, and can also heat hot water for domesticuse. This type of boileralternates between the two operating modes, with the “domestic hotwater” function takingprecedenceover the “buildingheat source” func-tion. These boilers are identified by the letter ”M” in their model numberor “V” for models combined with to external storage tanks.

2.4 Fume exhaust method

These boilers are equipped with a fan which forces the fumes throughan adequately---sized exhaust duct system; however, the combustionchamber is enclosed in a sealed chamber and is isolated from the in-stallation area. boilers using this system are identified by the letter ”S”in their model number, and do not use air from the installation area forcombustion.

3 MODEL IDENTIFICATION CODE/SERIALNUMBER

Every boiler produced by carries its own model identification code/se-rial number.

It is important for the service centre to mention this number when con-tacting the factory (the number must be listed on guarantee claims andservice reports; when making requests for technical information, etc.).

The following is a breakdown of the model identification code/serialnumber and its meaning (reading from left to right):

A) The maximum useful heating power during operation as a buildingheat source.

B) Themaximumusefuldomestic hotwater powerduring operation asthe heating of omestic hot water.

C) The type of boiler according to its functions

D) The type of gas used by this boiler. The letter “N” is used for Naturalgas; the letter “G” is used for liquefied petroleum gas (LPG).

E) The first five numbers are the actual serial number.

F) The last four numbers indicate the month (first two numbers) andthe year of construction.

These numbers are used in this catalogue to distinguish betweenversions of the same model with different modifications.

A Maxi-mumusefulheatingpower

C Type of boiler E Serial number

F Monthandyear ofcon-struc-tion

D Type of gasused by thisboiler

B Maxi-mumusefuld.h.w.power

M260MR.2025SM/T N210561116

4 REPLACEMENT PARTS CODE

Each currently available replacement part is uniquely identified by itsown replacement parts code. The replacement parts code consists ofa table code and a position code.

4.1 Table code

The table code is a sequence of letters and numbers which uniquelyand clearly identify each table. The table code can be found on theupper right of each table (see 4.3).

A validity chart for the table is located at the bottom of the table. Thischart lists the models covered by the table.

M260MR.2025SM/TM260MR.2025SV/T

M260MR.2530SM/TM260MR.2530SV/T

4.2 Position Code

The position code is a number which is used to identify a particular ob-ject on the table.

Tomake identification easier, position codes for kits have a different for-mat from position codes for individual parts.

515 125Position code for a kit(or assembly)

Position code for anindividual part

A label can be found next to the position code. This label is used to pro-vide additional information on the replacement part and makes identifi-cation of the part easier:

A --- Type of gas

G20 = Natural gas

G31 = Propane (LPG)

515 G20 G20125

515 G31 G31125

B --- Validity restrictions

For models M260MR.2025SV/T andM260MR.2530SV/T, only

For models M260MR.2025SM/Tand M260MR.2530M/T, only

515(SV) (SV)125

515 (SM) (SM)125

4.3 Composition of the replacement part code

Each replacement part code includes a table identification code and aposition code. A position code is only listed for replacement partswhichare currently available.

Page 3: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

The replacement part code consists of the table code (which can befound on the upper right of the table) plus the position code (in two for-mats: individual part or kit).

121+

515

=

+ =

BI1011

BI1011

BI1011 121

BI1011 515

Position code ofthe individual part

Position code ofthe kit

Replacement part number

The components of a kit are enclosed in a broken line. A kit may containother complete kits, or portions of other kits.

In some tables, a replacement part may be identified with an arrow anda complete replacement part code (table code + position code). Thismeans that the part is available, but must be ordered with the codelisted. Also, any explanatory notes must be read before ordering.

=BI1011 515

=BI1011 515(2530)

=BI1011 516(2025)

4.4 Using the replacement parts codeThe replacement parts codemust be included on all documents whichare used in service reports, orders for replacement parts, guaranteeclaims, etc.

Page 4: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

Spare parts list

Table Edition N˚ of pages

BI1441 Part 1 Water group 1116 1

BI1461 Part 1 Water group 1116 1

BI1491 Part 1 Water group 1116 1

BI1501 Part 1 Water group 1116 1

BI1772 Part 2 Water group 1116 1

BI1503 Part 3 Gas group 1116 1

BI2445 Part 5 Driving panel and electric parts 1116 1

BI2455 Part 5 Driving panel and electric parts 1116 1

BI2465 Part 5 Driving panel and electric parts 1116 1

BI1556 Part 6 External panels, fire chamber 1116 1

BI1913 Part 1 Spares 1116 1

Page 5: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SM/T

M260MR.2530SM/T

Part 1 -- Water group BI1441

1116

(10 l/min)

501

= BI1011 107

= BI1001 101(2025)

= BI1001 102(2530)

= BI1181 111

105

= BI1351 115

= KI1042 110

101

= BI1004 101

= BI1262 116

= BI1181 501

= BI1181 107

= BI1182 108

= BI1181 120

= KI1043 145

= KI1002 119

= BI1262 116= BI1351 102

107= KI1042 102

= BI1262 112

= BI1351 104

102

104= BI1351 104

= BI1262 112

= BI1351 106

= BI1351 114

= BI1351 104

106

= BI1001 108= BI1001 106

108

107

109502

= KI1043 144

111112110

113

= KI1042 501

100

Page 6: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 1 -- Water group BI1461

1116

100

= BI1011 107

= BI1181 111

= BI1351 115

= KI1042 110

= BI1004 101

= BI1262 116

= BI1181 501

= BI1181 107

= BI1182 108

= BI1181 120

= KI1043 145

= KI1002 119

= BI1262 116= BI1351 102

= BI1262 112

= BI1351 104

= BI1351 104

= BI1262 112

= BI1351 106

= BI1351 114

= BI1351 104

= BI1001 108= BI1001 106

101

500

= BI1441 101 = BI1441 100

= BI1441 102

= BI1441 107

= BI1441 108

= BI1441 113

= BI1441 111

= BI1441 112= KI1042 101

= BI1451 100

= BI1301 112

= KI1042 101

= BI1391 100

= KI1043 144

Page 7: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 1 -- Water group BI1491

1116

= BI1262 116

= BI1001 108

= BI1262 114

= BI1262 116

= KI1042 101= BI1351 102

= BI1351 111

= BI1431 100

= BI1011 107

= BI1351 104

= BI1351 112

= BI1351 113

= BI1431 101

= BI1351 117

= BI1262 112

= BI1351 112

= BI1351 115

= BI1262 112

= BI1351 114

= BI1301 112

= BI1301 112

= KI1042 101

= BI1381 101

100

101

= BI1451 100

= BI1441 105

Page 8: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SM/T

M260MR.2530SM/T

Part 1 -- Water group BI1501

1116

= BI1262 116

= KI1042 102

= KI1042 501

= KI1042 101

= BI1262 116

= BI1001 106

= BI1001 108

= BI1262 114

= BI1262 116

= BI1011 107

= KI1043 144

= BI1351 114

= BI1262 112

= BI1351 115

= BI1351 112

= BI1262 112

= BI1351 113

= BI1351 113

= BI1351 112= BI1351 102

= BI1351 111

= BI1351 104

= BI1491 101

= BI1351 106= BI1262 112

= BI1351 104

= BI1351 103

= BI1351 102

= BI1351 117

100

= BI1431 101

= BI1421 100

= BI1431 100

= BI1441 105

Page 9: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 2 -- Water group BI1772

1116

= KI1042 101

= BI1536 101

= BI1462 100

= BI1462 106

= BI1432 102

= BI1181 110

= BI1202 105

= BI1562 107

= BI1262 113

= BI1002 113

= BI1212 107

= BI1262 116

= BI1262 120

= BI1692 102

101

= BI1262 114

= BI1212 112

= BI1442 106

= BI1432 106

= BI1262 112

= BI1172 105

= BI1262 112

100

= BI1672 100

102103 (2530)

(2025)

104

105 106

108107 (2530)

(2025)

109

110

Page 10: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 3 -- Gas group BI1503

1116

= BI1313 111

= BI1313 103

= BI1001 108

= BI1453 116= BI1001 108 = BI1093 107

= BI1293 120

= BI1293 115

= BI1293 109

= BI1293 113

= BI1293 112

105

= BI1293 111

= BI1363 103

= BI1293 109

100

101102

103

106107 (2530)

(2025)

104

= BI1453 102

= BI1363 100

108

112113 (2530)

(2025)111

= BI1453 103

= BI1592 101

109110 (2530)

(2025)

501(G20)

502 (2530)(G20)

503(G31)

504 (2530)(G31)

(2025)

(2025)

Page 11: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 5 -- Driving panel and electric parts BI2445

1116

= BI1805 107 = BI1165 112

100

= BI1665 107

= BI1955 107

102

101= BI2035 108

= BI2035 117

= BI2035 120

= BI2035 118= BI2035 104

= BI2035 106

= BI2035 107

Page 12: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SM/T

M260MR.2530SM/T

Part 5 -- Driving panel and electric parts BI2455

1116

101

101101

101

100

= BI1503 108

= BI1363 103

= BI2265 102

= BI2385 111

= BI2045 106

= BI2265 103

= BI2265 105

100

100

100101

= BI2385 111

= BI2385 111

102

102

102

102

102

Page 13: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 5 -- Driving panel and electric parts BI2465

1116

= BI1985 104

= BI2455 101

= BI2455 100

= BI2455 100

= BI2455 100

= BI2455 100

= BI2455 101

= BI2385 111

= BI2265 105

= BI2455 101

= BI2385 111= BI2385 111

= BI2455 101

= BI2455 101

= BI1503 108

= BI1363 103

= BI2265 102

= BI2045 106

= BI2275 101

100

100

Page 14: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 6 -- External panels, fire chamber BI1556

1116

100

= BI1366 114

= BI1016 101

100

= BI1016 101

= BI1366 114

= BI1016 104

103

103

101

Page 15: Spare parts list series Inovia Cond Plus - quadroflex.sk · Spare parts list series Inovia Cond Plus Edition 11/2016 *1756227250* 17562.2725.0 REV1 29/11 2016 N

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

M260MR.2025SM/T

M260MR.2530SM/T

M260MR.2025SV/T

M260MR.2530SV/T

Part 1 -- Spares BI1913

Part Pos. N. T. Size

BI1001 115 10 12,42 x 1,78KI1043 144 10 18,64 x 3,53BI1001 503 10KI1043 114 10 17,04x3,53KI1001 105 10 17,13x2,62BI1475 119 10 7x2BI1212 112 10 17,04x4,00

BI1911 800 O--ring packing set

Part Pos. N. T. Size

BI1001 107 10 P 1/4”BI1001 109 10 P 3/8”BI1202 105 10 P 3/8”BI1001 106 10 P 1/2”BI1001 108 10 P 3/4”BI1001 105 10 P 1”

BI1901 802 Flat packing set

1116

= KI1901 101

Flue ductsgaskets Kit

502