23
EDIT. SHEET DRAW. NO. CUST. TITLE 1/23 DESCRIPTION DESIG. DATE Small machine operators panel B Connection manual A-80966E Small Machine Operator’s Panel B Connection Manual Contents 1. Configuration 2. Install Condition 3. Power supply rating 4. Connector Layout design 5. Total Connection Diagram 6. Connections 6.1 I/O Link Connection 6.2 Manual Pulse Generator Connection 6.3 General-purpose DI/DO Connection Pin Assignment 6.4 General-purpose DI(Input signals) Connection 6.5 General-purpose DO(Output signals) Connection 6.6 Emergency stop signal connection 6.7 DI/DO signal Specifications 6.8 ON/OFF of the power supply(DO common) DO signals(Output signals) 6.9 Parallel DO(Output signals) 6.10 Power supply Connection 7. Allocation 8. I/ O Address 8.1 Override signals 8.2 Keyboard 8.3 DO(Output signals) Alarm 9. Outline drawing 9.1 Outline drawing and panel-cut drawing of the small machine operator’s panel 9.2 Layout of the key sheet 01 060407 Okita FANUC LTD

SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

Embed Size (px)

Citation preview

Page 1: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

1/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

Small Machine Operator’s Panel B

Connection Manual

- Contents -

1. Configuration 2. Install Condition 3. Power supply rating 4. Connector Layout design 5. Total Connection Diagram 6. Connections

6.1 I/O Link Connection 6.2 Manual Pulse Generator Connection 6.3 General-purpose DI/DO Connection Pin Assignment 6.4 General-purpose DI(Input signals) Connection 6.5 General-purpose DO(Output signals) Connection 6.6 Emergency stop signal connection 6.7 DI/DO signal Specifications 6.8 ON/OFF of the power supply(DO common) DO signals(Output signals) 6.9 Parallel DO(Output signals) 6.10 Power supply Connection

7. Allocation 8. I/ O Address

8.1 Override signals 8.2 Keyboard 8.3 DO(Output signals) Alarm

9. Outline drawing 9.1 Outline drawing and panel-cut drawing of the small machine

operator’s panel 9.2 Layout of the key sheet

01 060407 Okita

FANUC LTD

Page 2: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

2/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

1. Overview

The small machine operator’s panel B is a machine operator’s panel connected to the CNC with an I/O Link. The Operator’s panel contains 30 keys, an emergency stop switch, and two override rotary switches. And it contains general-purpose DI/DO

(DI: 24 points, DO:16 points). The function except general-purpose DI/DO is the same as

the existing machine operator’s panel(A02B-0299-C150/T,/M) 30 keys

21 LEDs

Emergency stop switch(SB1) Override rotary switch(SA2) Override rotary switch(SA2)

Specification number: A02B-0309-C151/T(T Series)

A02B-0309-C151/M(M Series)

Small operator’s panel Specification Item Specificatio

n

Remark

Key switch of Machine Operator’s panel

30 keys Matrix DI

with detour prevention diode

LED 21 LEDs Supplied with 21 key switches

Override rotary switch 2 Gray code output(with a parity bit)

Emergency stop switch 1 Number of contact:4

Contact type A x 2, Contact type B x 2

Connector for emergency stop

signal

1 Connect to general-purpose DI(Xm2+4.4)

MPG interface Max. 3 units

General-purpose DI 24 points

General-purpose DO 16 points

FANUC LTD

Page 3: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

3/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

2. Install condition

Ambient temperature for the unit

Operation: 0℃ to 55℃ Storage and transportation: -20℃ to 60℃

Temperature change

1.1℃/minute maximum

Humidity Normal condition: 75%(relative humidity) Short term(within one month): 95% (relative humidity)

Vibration Operation : 0.5G or less Atmosphere Normal machining factory environment(For use in an environment with

relatively high levels of dust, coolant, organic solutions and so forth, additional measures are required.)

Other conditions

Use each I/O module in a completely sealed cabinet.

3. Power supply rating DC24V±10% 0.4A (from Power connector CPD1, including momentary value)

Momentary value and ripples are also includes in ±10%.

4. Connector Layout design I/O board - Key board(CE72)

I/O Link connector (JD1A) I/O Link connector (JD1B) MPG connector (JA3) Emergency stop signal input connector (CE74)

FANUC LTD

+24VDC input connector (CPD1)

General-purpose DI/DO connector (CE73)

Rotary switch (SA2) signal input connector (CM66) Rotary switch (SA1) signal Fuse(1A) input connector (CM65)

Page 4: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

4/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

5. Total Connection Diagram

FANUC LTD

Pin 02 in connector CE74 is connected to general-purpose DI Xm2+4.4.

In case of allocating general-purpose DI addresses from X0004, Emergency switch signal

can be connected directly to CE74, because Pin 02 in connector CE72 is allocated to address

X0008.4.

JD1B

JD1A

JA3 MPG

MPG

MPG

CA102

I/O Link JD1A(JA44)

Control unit or slave unit in previous stage

JD1B

I/O link slave unit

CE72

+24VDC Power supply

I/O board

Rotary switch (SA1)

keyboard

Small machine operator’s panel

Rotary switch(SA2)

CE73 General-purpose DI/DODI:24 points DO:16 points

Emergency stop switch (SB1)

CM66

CE74

CM65

CE72

Page 5: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

5/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6. Connections

6.1 I/O Link Connection

Small machine operator’s panel B

FANUC LTD

Cable connection

JD1A (PCR-EV20MDT) 1 SIN 11 0V

2 *SIN 12 0V

3 SOUT 13 0V

4 *SOUT 14 0V

5 15

6 16

7 17

8 18 (+5V)

9 (+5V) 19

10 20 (+5V)

JD1B (PCR-E20MDK-SL-A) 1 SIN 11 0V

JD1B 2 *SIN 12 0V

3 SOUT 13 0V

4 *SOUT 14 0V

5 15

6 16

7 17

8 18 (+5V)

9 (+5V) 19

10 20 (+5V)

JD1A (PCR-E20MDK-SL-A)

JD1A 1 SIN 11 0V

2 *SIN 12 0V Control unit or previous slave unit 3 SOUT 13 0V

Next slave unit

4 *SOUT 14 0V

5 15

6 16

7 17

8 18 (+5V)

9 (+5V) 19

10 20 (+5V)

SIN*SINSOUT

*SOUT0V0V0V0V

1 2 3 4 11 12 13 14

3412

11121314

SOUT *SOUT SIN *SIN 0V 0V 0V 0V

Shield

Ground plate

Recommended wire material: A66L-0001-0284#10P(#28AWG x 10 pair)

Page 6: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

6/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.2 Manual Pulse Generator Connection

Small machine operator’s panel B

FANUC LTD

Wiring

JA3 (PCR-E20MDK-SL-A) 1 HA1 11

2 HB1 12 0V

3 HA2 13

4 HB2 14 0V

5 HA3 15

6 HB3 16 0V

7 17

8 18 +5V

9 +5V 19

10 20 +5V

Manual Pulse Generator #1 (M3 Screw)

3 4 5 6 +5V 0V HA1 HB1

Manual Pulse Generator #2 (M3 Screw)

3 4 5 6 +5V 0V HA2 HB2

Manual Pulse Generator #3 (M3 Screw)

3 4 5 6 +5V 0V HA3 HB3

HA1HB1+5V0V

HA2HB2+5V0V

HA3HB3+5V0V

1 2 9 12 3 4 18 14 5 6 20 16

Shield

7BK 7WH 5RD 5BK 8RD 8BK 4RD 3BK 9BK 9WH 6RD 1BK

HA1HB1+5V0V

HA2HB2+5V0V

HA3HB3+5V0V

HA1 #1 HB1 +5V 0V

HA3 #3 HB3 +5V 0V

HA2 #2 HB2 +5V 0V

5 6 3 4 5 6 3 4 5 6 3 4

Ground Cable

Cable connection

Terminal Manual Pulse Generator

Recommended wire material:A66L-0001-0286(#20AWG x 6 pair or #24AWG x 3 pair) Recommended Connector:A02B-0120-K303(including the follow connector and case)

(Connector:FI40B-2015S(Hirose Electric Co., Ltd)) (Case: FI-20-CV5(Hirose Electric Co., Ltd)) Recommended Cable:A02B-0120-K841(7m)(for connecting three manual pulse generator) A02B-0120-K848(7m) (for connecting two manual pulse generator) A02B-0120-K847(7m) (for connecting one manual pulse generator) (These cables do not include the wire shown in the above figure)

Page 7: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

7/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

Cable length for Manual pulse generator

The Manual pulse generator operates on 5VDC. The supply voltage drop due to the

Cable resistance must me held below 0.2V(when 0-volt and 5-volt wires are combined),

as expressed in the following expression:

0.1 x R x 2L 0.2 ≧ m Where

0.1: Manual pulse generator supply current(0.1A)

R : resistance per unit cable length (ohm/m)

M : number of 0-volt and 5-volt wires

L : cable length(m)

Therefore, the cable length can be determined using the following expression.

m L ≦ R

For Example, when cable A66L-0001-0286 is used.

The cable consists of three pairs of signal lines and six power wires

(20/0.18,0.0394Ω/m).

When these three cables are used for 0V and 5V Lines, the cable length is:

3 L ≦ = 76.75(m) 0.0394 Thus, the length is 76.75m. (Because of applicable regulation of FANUC,

however, the length is limited to 50m)

For two units, the cable can be extended to 38.37m.

For three units, it can be extended to 25.58m.

FANUC LTD

Page 8: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

8/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.3 General-purpose DI/DO Connection Pin Assignment

FANUC LTD

A B

01

0V +24V

02 Xm2+0.0 Xm2+0.1

03 Xm2+0.2 Xm2+0.3

04 Xm2+0.4 Xm2+0.5

05 Xm2+0.6 Xm2+0.7

06 Xm2+4.0 Xm2+4.1

07 Xm2+4.2 Xm2+4.3

08 Xm2+4.4 Xm2+4.5

09 Xm2+4.6 Xm2+4.7

10 Xm2+5.0 Xm2+5.1

11 Xm2+5.2 Xm2+5.3

12 Xm2+5.4 Xm2+5.5

13 Xm2+5.6 Xm2+5.7

14 DICOM0

DICOM5

15

16 Yn2+0.0 Yn2+0.1

17 Yn2+0.2 Yn2+0.3

18

Yn2+0.4 Yn2+0.5

19 Yn2+0.6 Yn2+0.7 20 Yn2+1.0 Yn2+1.1

21 Yn2+1.2 Yn2+1.3

22 Yn2+1.4

Yn2+1.5

23 Yn2+1.6 Yn2+1.7

24

DOCOM DOCOM

25 DOCOM DOCOM

General-purpose DI/DO(CE73)

Flat cable-side connector specification:

A02B-0120-K342 (HIF3BB-50D-2.54R(Hirose Electric Co.,Ltd))

50 contacts

Cable material specification:

A02B-0120-K886

(61-meter, 50-pin cable ((Hitachi cable.,LTD or Oki Electric Cable Co.,Ltd))

1.Xm2 and Yn2 are top addresses of general-purpose DI/DO.

2.An output DC voltage of +24V at CE73(B01) is for DI signals.

Do not supply +24VDC to this pin from the outside.

Page 9: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

9/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.4 General-purpose DI(Input signals) Connection

Pin number

FANUC LTD

RV Xm2+0.0 CE73(A02)

RV Xm2+0.1 CE73(B02)

RV Xm2+0.2 CE73(A03)

RV Xm2+0.3 CE73(B03)

RV Xm2+0.4 CE73(A04)

RV Xm2+0.5 CE73(B04)

RV Xm2+0.6 CE73(A05)

RV Xm2+0.7 CE73(B05)

0V

Address number

Bit number

Xm2+4.0 CE73(A06)

Xm2+4.1 CE73(B06)

Xm2+4.2 CE73(A07)

Xm2+4.3 CE73(B07)

Xm2+4.4 CE73(A08)

Xm2+4.5 CE73(B08)

Xm2+4.6 CE73(A09)

Xm2+4.7 CE73(B09)

0V

DICOM0

CE73(A14)

CE73(A01)

+24V

RV

RV

RV

RV

RV

RV

RV

RV

In case of DI pins from Xm+0.0 to Xm+0.7, their common signal(DICOM0) is selectable.

CE73(B01)

+24V

CE74(02)

CE74(01)

emergency stop Switch

note: Refer to item 6.6

Page 10: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

10/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

FANUC LTD

RV

RV

RV

RV

RV

RV

RV

RV

0V CE73(A01)

Xm2+5.0

Xm2+5.1

Xm2+5.2

Xm2+5.3

Xm2+5.4

Xm2+5.5

Xm2+5.6

Xm2+5.7

DICOM5

CE73(B14)

CE73(A10)

CE73(B10)

CE73(A11)

CE73(B11)

CE73(A12)

CE73(B12)

CE73(A13)

CE73(B13)

+24V

CE73(B01)

Pin number

Address number

Bit number

In case of DI pins from Xm+5.0 to Xm+5.7, their common signal(DICOM5) is selectable.

Page 11: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

11/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.5 General-purpose DO(Output signals) Connection Pin number

FANUC LTD

DOCOM

DV

Yn2+0.0 CE73(A16)

DVYn2+0.1 Yn2+0.2 Yn2+0.3 Yn2+0.4 Yn2+0.5 Yn2+0.6 Yn2+0.7

CE73(B16) CE73(A17) CE73(B17) CE73(A18) CE73(B18) CE73(A19) CE73(B19)

DV

DV

DV

DV

DV

DV

Relay

CE73(A24,A25,B24,B25)

DV

DV

DV

DV

DV

DV

DV

DV CE73(A20) CE73(B20) CE73(A21) CE73(B21) CE73(A22) CE73(B22) CE73(A23) CE73(B23)

0V

CE73(A01)

Address number +24V 0VBit number +24V Stabilized

power supply

Yn2+1.0 Yn2+1.1 Yn2+1.2 Yn2+1.3 Yn2+1.4 Yn2+1.5 Yn2+1.6 Yn2+1.7

Page 12: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

12/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.6 Emergency stop signal connection

The emergency stop switch has contact A in two circuits and contact B

in two circuits.

FANUC LTD

Emergency stop switch(SB1)

M3.5 Screw

terminal

Pin 02 in connector CE74 is connected to general-purpose DI Xm2+4.4.

In case of allocating general-purpose DI addresses from X0004, Emergency switch signal

can be connected directly to CE74, because Pin 02 in connector CE72 is allocated to address

X0008.4.

When input signal(Xm2 + 4.4) is used for emergency stop signal,

input it to CE74(02) or CE73(A08).

CE74 Cable-side connector specification:

Manufacturer: Tyco electronics AMP,.Ltd

Housing: 1-1318120-3

Contact: 1318107-1(0.30mm2 - 0.85mm2)

Xm2+4.4 CE73(A08)

0V

RV

CE74(02)

+24V

Small machine operator’s panel B Emergency stop switch

CE74(01)

Page 13: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

13/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.7 DI/DO signal Specifications The specifications of the DI/DO signals used with the small operator’s panel B is shown as below.

DI(Input signal specifications) Number of points 48 points (per module) Contact rating DC30V、16mA or more Leakage current between Contacts when opened

1mA or less(26.4V)

Voltage decrease Between Contacts when closed

2V or less (including cable voltage decrease)

Delay time The receiver delay is 2 ms(maximum). In addition, [I/O Link transfer time between CNC and Small machine operator’s panel B (2msmaximum)] + [ladder scan period(depending on CNC)] must be considered.

DO(Output signal specifications) Number of points 32 pints (per module) Maximum load current (ON)

200mA or less including momentary variations

Saturation voltage (ON)

1V(maximum) when the load current is 200mA

Withstand voltage 24V + 20% or less including momentary variations Leakage current (ON)

20μA or less

Delay time The receiver delay is 50μs(maximum). In addition, [I/O Link transfer time between CNC and Small machine operator’s panel B (2msmaximum)] + [ladder scan period(depending on CNC)] must be considered.

6.8 ON/OFF of the power supply(DO common) for DO signals(output signals) By turning off(opening) the power supply pin(DOCOM) for the DO signals(output signals),All the DO signals of each module can be turned off the same time. At this time, The DO state is as shown below.

ON

FANUC LTD

Note: When DO is on in the sequence, the ON/OFF state of DOCOM is directly reflected

in the DO state.

OFF

ON OFF

ON OFF

DO state when DO is on in the sequence

DO state when DO is off in the sequence

DOCOM

Page 14: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

14/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

6.9 Parallel DO(Output signals)

A DO load current of twice the level can be obtained by connecting DO points in parallel

and exercising ON/OFF control at the same time in the sequence. Namely, the maximum

load current per DO point is 200mA.By connecting two DO points in parallel and turning

on the two DO points at the same time, 400mA can be obtained. In this case, however,

the leakage current is doubled up to 40μA when the DO points are turned off.

FANUC LTD

6.10 Power supply Connection

Note : The +24V signal to be supplied to this operator’s panel must not be turned off during operation. Otherwise, a CNC communication alarm is issued.

Ensure that +24V is supplied to it either when or before the power to the CNC is turned on, and that +24V is removed either when or after the power to the CNC is turned off.

DOCOM

Relay

CE73(A24,A25,B24,B25)

DV

DV

0V

Small machine operator’s panel B

+24V 0V

+24V Stabilized power supply

Small machine operator’s panel B +24V

CPD1(01)

CPD1(02)

+24V 0V

+24V Stabilized power supply

0V

Page 15: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

15/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

7. Allocation

Normally, one unit is allocated to I/O Link as one group.

Small machine operator’s panel B has two circuits(for operator’s panel and

for general-purpose DI/DO), and these circuits must be allocated as two groups

which were continued in the order as from operator’s panel to general-purpose DI/DO

circuit.

Follow figure is the example when operator’s panel circuit is allocated to group 0.

Generate-purpose DI/DO circuit must be allocated to group 1, and next other I/O

module must be allocated to group 2.

FANUC LTD

CNC

JD1A

Small machine operator’s panel B JD1B operator’s panel function(group 0)

JD1A general-purpose function(group 1)

I/O module JD1B (group 2) JD1A

I/O module JD1B (group 3) JD1A

Page 16: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

16/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

operator’s panel (group#0) DI map DO map

Xm1 + 0 Rotary switch (SA1) Yn1 + 0

FANUC LTD

Xm1 and Yn1 indicate the start address of operator’s panel circuit.

Xm2 and Yn2 indicate the start address of general-purpose DI/DO circuit.

Xm1 + 1 Rotary switch (SA2) Yn1 + 1 operator’s panel

Xm1 + 2 Yn1 + 2 keyboard (LED) Reserve

Xm1 + 3 Yn1 + 3 Xm1 + 4 Yn1 + 4 Xm1 + 5 Yn1 + 5

operator’s panel

Xm1 + 6 Yn1 + 6 keyboard

Xm1 + 7 Yn1 + 7 Reserve (key switch)

Xm1 + 8 Xm1 + 9 Xm1 + 10

Reserve

Xm1 + 11 Xm1 + 12 1st MPG Xm1 + 13 2nd MPG Xm1 + 14 3rd MPG Xm1 + 15 DO Alarm

General-purpose DI/DO (group#1)

DI map DO map Xm2 + 0 General-purpose DI Yn2 + 0 General-purpose DOXm2 + 1 Yn2 + 1 General-purpose DOXm2 + 2

Reserve

Xm2 + 3 Xm2 + 4 General-purpose DI Xm2 + 5 General-purpose DI Xm2 + 6 Xm2 + 7

Xm2 + 8 Reserve

Xm2 + 9 Xm2 + 10 Xm2 + 11 Xm2 + 12 Xm2 + 13 Xm2 + 14 Xm2 + 15 DO Alarm

Page 17: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

17/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

FANUC LTD

Module name

DI DO

Operator’s panel circuit CM16I(16byte) CM08O(8byte)

General-purpose DI/DO circuit

CM06I(6byte) CM02O(2byte)

In case of using DO alarm in general-purpose DI/DO area, general-purpose DI/DO

circuit must be allocated as 16byte area. In this case the module name of

general-purpose DI/DO circuit is CM16I.

In case of allocating DI of general-purpose DI/DO from X004, the fixed signals

such

as SKIP, DECn, and *ESP are allocated as follows.

Fixed address directly supervised by the CNC

7 6 5 4 3 2 1 0 SKIP ESKIP

SKIP6 -MIT2 SKIP5

+MIT2 SKIP4

-MIT1 SKIP3

+MIT1 SKIP2

ZAE SKIP8

XAE SKIP7

X004

SKIP ESKIP SKIP6

SKIP5 SKIP4 SKIP3 ZAE SKIP2

YAE SKIP8

XAE SKIP7

X005 X006 X007 X008 *ESP X009 *DEC4 *DEC3 *DEC2 *DEC1

Page 18: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

18/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

FANUC LTD

8. I/ O Address

8.1 Override signals

Gray codes are output according to following.

Rotary switch(SA1)

% 0 1 2 4 6 8 10 15 20 30 40 50 60 70 80 90 95 100 105 110 120

Xm1+0.0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

Xm1+0.1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1

Xm1+0.2 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1

Xm1+0.3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1

Xm1+0.4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1

Xm1+0.5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

Rotary switch(SA2)

% 50 60 70 80 90 100 110 120

Xm1+1.0 0 1 1 0 0 1 1 0

Xm1+1.1 0 0 1 1 1 1 0 0

Xm1+1.2 0 0 0 0 1 1 1 1

Xm1+1.3 0 0 0 0 0 0 0 0

Xm1+1.4 0 1 0 1 0 1 0 1

Xm1+1.5 0 0 0 0 0 0 0 0

Note:

1. Xm1+0.5 and Xm1+1.4 are parity bits.

2. If parity bits are used, the output timing of override signals may differ

from timing of the parity bits.

Page 19: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

19/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

8.2 Keyboard

The I/O address correspondence table between the key switches and the small machine

operator’s panel B LEDs are as follows.

FANUC LTD

BIT Key/LED

5 4 3 2 1 0

Xm1+4/Yn1+0 A6 A5 A4 A3 A2 A1

Xm1+5/Yn1+1 B6/

Without LED

B5/

Without LED

B4/

Without LED

B3 B2 B1

Xm1+6/Yn1+2 C6/

Without LED

C5/

Without LED

C4/

Without LED

C3 C2 C1

Xm1+7/Yn1+3 D6

Without LED

D5

Without LED

D4

Without LED

D3 D2 D1

Xm1+8/Yn1+4 E6 E5 E4 E3 E2 E1

Key switch/LED arrangement

Location

Page 20: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

20/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

FANUC LTD

8.3 DO(Output signals) Alarm

The DO driver of small machine operator’s panel B is capable of detecting an over

current and measuring its own temperature. If an accident, such as the connecting of the

cable to ground, causes an abnormal increase in the load current or in the driver

temperature, a protection circuit , which is provided for each DO driver(1 byte), is

activated and keeps the DO signal for the relevant 1 byte in the OFF state until the

cause of the problem is eliminated. Even if this occurs, the CNC and small operator’s

panel B continue operating. The DI address(both Xm1+15 and Xm2+15) identifies the

DO driver which has detected the alarm. The following table shows the correspondence

between the DI address(Xm1+15 or Xm2+15) bits and the DO addresses. Manage the

alarm well by using Ladder program with bit signals in following table, when DO status

becomes abnormal.

Alarm detection Address and bit

DO address

Xm1+15.0 or Xm2+15.0 Yn2+0 Xm1+15.1 or Xm2+15.1 Yn2+1

Page 21: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

21/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

9. Outline drawing

9.1 Outline drawing and panel-cut drawing of the small machine operator’s panel

FANUC LTD

Unit:mm

Weight: 1.5kg Panel-cut drawing

Page 22: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

22/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

9.2 Layout of the keysheet M Series

FANUC LTD

Page 23: SPEC06/056 A-80966E Small Machine Operator’s Panel … · A-80966E Small Machine Operator’s Panel B ... relatively high levels of dust, ... FANUC LTD RV Xm2+0.0 CE73(A02) RV

EDIT.

SHEET

DRAW. NO. CUST.

TITLE

23/23DESCRIPTIONDESIG.DATE

Small machine operator’s panel BConnection manual

A-80966E

TSeries