12
February 15th, 2017 DOOR NOTE #1: UNITS NOT APPROVED FOR WATER INFILTRATION MUST BE INSTALLED AT LOCATIONS PROTECTED BY AN OVERHANG MEETING CRITERIA AS PER ILLUSTRATION BELOW OR IN NON-HABITABLE AREAS WHERE WATER INFILTRATION IS ACCEPTABLE. EXTERIOR OH RATIO = OVERHANG LENGTH OVERHANG HEIGHT SERIES 16, 17, 19-1, & 20 ALUMINUM FRAME OUTSWING DOOR (LMI & SMI) - METAL STRUCTURES NOT BY SPECIAL-LITE, INC. MUST SUPPORT LOADS IMPOSED BY DOOR SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. - WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. - A LOAD DURATION FACTOR IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. - DOOR PANEL: 0.120" PEBBLE FRP SKIN, 0.0625" ALUMINUM SKIN, 0.120" SANDSTONE FRP SKIN, 0.125" ALUMINUM SKIN OR 0.120" AMP SKIN. - DOOR FRAME: ALUMINUM 6063- T6 - THE DESIGN LOADS SHOWN IN THIS DOCUMENT ARE ALLOWABLE DESIGN LOADS. ULTIMATE LOAD OBTAINED FROM ASCE 7-10, MULTIPLY BY 0.6 SHALL BE LESS THAN OR EQUAL TO MAX. DESIGN LOAD IN THIS DOCUMENT. -LOCK: REFER TO PAGE # 8 FOR LOCK OPTIONS. - THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 5TH EDITION FLORIDA BUILDING CODE (2014), TO BE USED INSIDE HIGH VELOCITY HURRICANE ZONE (HVHZ). - DOORS RATED FOR LARGE AND SMALL MISSILE IMPACT AND DO NOT REQUIRE SHUTTERS. - DOORS WITH WATER RESISTANT COMPONENTS APPROVED FOR WATER INFILTRATION, REFER TO DETAILS ON PAGE #5. - ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON ELEVATIONS. ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. - ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. - MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 5TH EDITION FLORIDA BUILDING CODE (2014) SECTION AS APPLICABLE. NOTE: EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. OVERHANG LENGTH OVERHANG HEIGHT ≥ 1 D.L.O. - DAYLITE OPENING F.H. - FRAME HEIGHT F.W. - FRAME WIDTH W/ - WITH W/O - WITHOUT O.C. - ON CENTER MAX. - MAXIMUM SECTION NUMBER SHEET NUMBER LIMITATIONS OF USE THIS PRODUCT EVALUATION DOCUMENT (P.E.D.) PREPARED BY THIS ENGINEER IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT; i.e .WHERE THE SITE CONDITIONS DEVIATE FROM THE P.E.D. CONTRACTOR TO BE RESPONSIBLE FOR THE SELECTION, PURCHASE AND INSTALLATION OF THIS PRODUCT BASED ON THIS PRODUCT EVALUATION PROVIDED HE/SHE DOES NOT DEVIATE FROM THE CONDITIONS DETAILED ON THIS DOCUMENT. THIS PRODUCT EVALUATION DOCUMENT WILL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. SITE SPECIFIC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCHITECT WHICH WILL BECOME THE ENGINEER OF RECORD (E.O.R.) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF THE P.E.D. THIS P.E.D. SHALL BEAR THE DATE AND ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER OF RECORD THAT PREPARED IT. A- B- C- D- E- MCY ENGINEERING, INC. GLAZING CONSULTANTS M C Y ALUMINUM FRAME OUTSWING DOORS OF 12 1 COVER SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS LARGE AND SMALL MISSILE IMPACT (HVHZ)

SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

DO

OR

NOTE #1:UNITS NOT APPROVED FOR WATER INFILTRATIONMUST BE INSTALLED AT LOCATIONS PROTECTED BYAN OVERHANG MEETING CRITERIA AS PERILLUSTRATION BELOW OR IN NON-HABITABLE AREASWHERE WATER INFILTRATION IS ACCEPTABLE.

EXTERIOR

OH RATIO = OVERHANG LENGTHOVERHANG HEIGHT

SERIES 16, 17, 19-1, & 20 ALUMINUM FRAME OUTSWING DOOR (LMI & SMI) - METAL STRUCTURES NOT BY SPECIAL-LITE, INC. MUST SUPPORT LOADS IMPOSED BY DOOR SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE.

- WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THESTRUCTURE.

- A LOAD DURATION FACTOR IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTOWOOD ONLY.

- DOOR PANEL: 0.120" PEBBLE FRP SKIN, 0.0625" ALUMINUM SKIN, 0.120" SANDSTONE FRPSKIN, 0.125" ALUMINUM SKIN OR 0.120" AMP SKIN.

- DOOR FRAME: ALUMINUM 6063- T6

- THE DESIGN LOADS SHOWN IN THIS DOCUMENT ARE ALLOWABLE DESIGN LOADS.ULTIMATE LOAD OBTAINED FROM ASCE 7-10, MULTIPLY BY 0.6 SHALL BE LESSTHAN OR EQUAL TO MAX. DESIGN LOAD IN THIS DOCUMENT.

-LOCK:REFER TO PAGE # 8 FOR LOCK OPTIONS.

- THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 5TH EDITION FLORIDA BUILDING CODE (2014), TO BE USED INSIDEHIGH VELOCITY HURRICANE ZONE (HVHZ).

- DOORS RATED FOR LARGE AND SMALL MISSILE IMPACT AND DO NOT REQUIRE SHUTTERS.

- DOORS WITH WATER RESISTANT COMPONENTS APPROVED FOR WATER INFILTRATION, REFERTO DETAILS ON PAGE #5.

- ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON ELEVATIONS. ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.

- ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL.

- MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF

THE 5TH EDITION FLORIDA BUILDING CODE (2014) SECTION AS APPLICABLE.

NOTE: EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL.

OVERHANG LENGTH

OVER

HANG

HEI

GHT

≥ 1D.L.O. - DAYLITE OPENINGF.H. - FRAME HEIGHTF.W. - FRAME WIDTHW/ - WITHW/O - WITHOUTO.C. - ON CENTERMAX. - MAXIMUM

SECTION NUMBER

SHEET NUMBER

LIMITATIONS OF USE

THIS PRODUCT EVALUATION DOCUMENT(P.E.D.) PREPARED BY THIS ENGINEER ISGENERIC AND DOES NOT PROVIDEINFORMATION FOR A SITE SPECIFICPROJECT; i.e .WHERE THE SITECONDITIONS DEVIATE FROM THE P.E.D.

CONTRACTOR TO BE RESPONSIBLE FORTHE SELECTION, PURCHASE ANDINSTALLATION OF THIS PRODUCT BASEDON THIS PRODUCT EVALUATION PROVIDEDHE/SHE DOES NOT DEVIATE FROM THECONDITIONS DETAILED ON THISDOCUMENT.

THIS PRODUCT EVALUATION DOCUMENTWILL BE CONSIDERED INVALID IF ALTEREDBY ANY MEANS.

SITE SPECIFIC PROJECTS SHALL BEPREPARED BY A FLORIDA REGISTEREDENGINEER OR ARCHITECT WHICH WILLBECOME THE ENGINEER OF RECORD(E.O.R.) FOR THE PROJECT AND WHO WILLBE RESPONSIBLE FOR THE PROPER USE OFTHE P.E.D.

THIS P.E.D. SHALL BEAR THE DATE ANDORIGINAL SEAL AND SIGNATURE OF THEPROFESSIONAL ENGINEER OF RECORDTHAT PREPARED IT.

A-

B-

C-

D-

E-

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 121

COVER

SPECIAL-LITE, INC.ALUMINUM FRAME OUTSWING DOORS

LARGE AND SMALL MISSILE IMPACT (HVHZ)

Page 2: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 122

E1

TYPICAL EXTERIOR ELEVATION (XX)

2" 47 3/4" MAX.DOOR WIDTH

47 3/4" MAX.DOOR WIDTH

27 3/4" MAX.D.L.O.

27 3/4" MAX.D.L.O.

2"

99

" MAX.

FRAM

E HEI

GHT

96

" MAX.

DO

OR H

EIG

HT

37

1/4

" MAX.

D.L

.O.

22

3/4

" MAX.

D.L

.O.

4 1

/4" M

AX.

FRO

M E

ND

S1

1"

MAX.

O.C

.

6" MAX.FROM ENDS

12" MAX.O.C.

101" MAX.FRAME WIDTH

6" MAX.FROM ENDS

12" MAX.O.C.

3"3"3"

3"3"3"(4) TYPE A OR B

ANCHORTYPE

# OFANCHORREQUIRED

MAX.SHIM

ABC

61/2"53

1/2"1/4"

10"MIN.

10"MIN.

10"MIN.

10"MIN.

12"

MIN

.12"

MIN

.12"

MIN

.

99

" MAX.

FRAM

E HEI

GHT

12

"1

2"96

" MAX.

DO

OR O

PENIN

G 37

1/4

"1

2"

22

3/4

"

6" MAX.FROM ENDS

52 1/4" MAX.FRAME WIDTH

12" MAX.O.C.

27 3/4" MAX.D.L.O.

10"MIN.

10"MIN.

47 3/4" MAX.DOOR WIDTH

2"2"

4 1

/4" M

AX.

FRO

M E

ND

S11" M

AX.

O.C

.

6" MAX.FROM ENDS

12" MAX.O.C.

TYPICAL EXTERIOR ELEVATION (X)

WITH OR WITHOUT WATERINFILTRATION

+65.0 PSF - 65.0 PSF

DESIGN LOADS (FOR SIZES SHOWN OR SMALLER)

AS PERMITTED BY FBC

DESIGN LOADS (FOR SIZES SHOWN OR SMALLER)

AS PERMITTED BY FBC

APPROVED FOR WATERINFILTRATION

DESIGN LOADS (FOR SIZES SHOWN OR SMALLER)

AS PERMITTED BY FBC

NOT APPROVED FOR WATERINFILTRATION

+ 65.0 PSF - 65.0 PSF

+ 47.0 PSF - 65.0 PSF

4 1

/4" M

AX.

FRO

M E

ND

S

SECTION BSECTION A

SIM.

FOR LOCK OPTIONSSEE SHEET HW1

Page 3: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

88 7/8" MAX.FRAME WIDTH

42" MAX.DOOR WIDTH

42" MAX.DOOR WIDTH

18" MAX.D.L.O.

6" MAX.FROM ENDS

98 3

/4" M

AX.

FRAM

E HEI

GHT

4 1

/4" M

AX.

FRO

M E

ND

S11" M

AX.

O.C

.

37 1

/4" M

AX.

D.L

.O.

23" M

AX.

D.L

.O.

96" M

AX.

DO

OR H

EIG

HT

TYPICAL EXTERIOR ELEVATION (XX)

2" 2"

3"3"3"

(4) TYPE A OR B

3"3"3"12" MAX.O.C.

6" MAX.FROM ENDS

12" MAX.O.C.

18" MAX.D.L.O.

NOT APPROVED FOR WATERINFILTRATION

+65.0 PSF - 65.0 PSF

DESIGN LOADS (FOR SIZES SHOWN OR SMALLER)

AS PERMITTED BY FBC

# OFANCHORREQUIRED

MAX.SHIM

ABC

51/2"53

1/2"1/4"

12

"M

IN.

12

"M

IN.

11

3/4

"M

IN.

12"MIN.

12"MIN.

12"MIN.

12"MIN.

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 123

E2

7 1

/2"

CONT. HINGE LAYOUT

EQ.

BUTT HINGE LAYOUT

7 1

/2"

EQ.

EQ.

SECTION A

FOR LOCK OPTIONSSEE SHEET HW1

ANCHORTYPE

HINGE OPTIONSBALL BEARING HINGE CONTINUOUS HINGE

Page 4: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

NOTE:GLASS COMPLIES WITH ASTME1300-09 (3 SEC. GUSTS).

GLASS TYPE 'G1'5/16" NOMINAL OVERALL GLASS TYPE 'G2'

1" NOMINAL OVERALLGLASS TYPE 'G3'1" NOMINAL OVERALL

1/4" TEMP. GLASS

0.090" BUTACITE INTERLAYERBY 'KURARAY AMERICA, INC.' 7/16" AIR SPACE

1/8" H.S. GLASS

1/8" H.S. GLASS

GLASS TYPE 'G4'1" NOMINAL OVERALL

1/4" TEMP. GLASS

0.090" BUTACITE INTERLAYERBY 'KURARAY AMERICA, INC.' 5/16" AIR SPACE

1/8" H.S. GLASS

1/8" H.S. GLASS

GLASS TYPE 'G5'7/8" NOMINAL OVERALL

0.090" BUTACITE INTERLAYERBY 'KURARAY AMERICA, INC.'

1/4" AIR SPACE

1/4" TEMP. GLASS

1/8" H.S. GLASS

1/8" H.S. GLASS

GLASS TYPE 'G6'5/16" NOMINAL OVERALL

3/8" POLYCARBONATE

5/8

"G

LASS B

ITE

1 1

/16

"G

LASS B

ITE

1/8" H.S. GLASS

0.090" BUTACITE INTERLAYERBY 'KURARAY AMERICA, INC.'

1/8" H.S. GLASS

1/4" TEMP. GLASS

0.090" BUTACITE INTERLAYERBY 'KURARAY AMERICA, INC.' 3/8" AIR SPACE

1/8" H.S. GLASS

1/8" H.S. GLASS

1 3

/16

"G

LASS B

ITE

1 3

/16

"G

LASS B

ITE

1 1

/16

"G

LASS B

ITE

1 1

/16

"G

LASS B

ITE

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 124

G11 3

/16

"G

LASS B

ITE

1 1

/16

"G

LASS B

ITE

GLAZING CORNER THRU BOLT DETAIL

DOW CORNING 995

EXT.

#10-32 X 2" MS W/ NUTS @ 11" O.C. @ VERTICAL SIDE& 11.5" O.C. @ TOP/BOTTOM.

#10-32 X 2" MS W/ NUTS @ 11" O.C. @ VERTICAL SIDE& 11.5" O.C. @ TOP/BOTTOM.

#10-32 X 2" MS W/ NUTS @ 11" O.C. @ VERTICAL SIDE& 11.5" O.C. @ TOP/BOTTOM.

GLAZING FOAM TAPEGLAZING FOAM TAPEDOW CORNING 995 GLAZING FOAM TAPEDOW CORNING 995

GLAZING FOAM TAPEDOW CORNING 995 GLAZING FOAM TAPEDOW CORNING 995

GLAZING FOAM TAPE

12-28 X 1-1/2"PH MS W/ NUT

12-28 X 1-1/2" PH MS W/ NUT

12-28 X 1-1/2" PH MS W/ NUT

12-28 X 1-1/2" PH MS W/ NUT

12-28 X 1-1/2" PH MS W/ NUT

EXT. EXT.

EXT. EXT. EXT.

EXT. EXT.

Page 5: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

MIN

.EM

BED

.

MIN.EDGE DIST.

MIN.EDGE DIST.

EXTE

RIO

R

D1A2

"2

13

/16

"CONCRETEf'c = 3000 psi MIN.

D1B

1/2

" SHIM

MAX.

9/1

6"

CONCRETEf'c = 3000 psi MIN.

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 12

#8 X 5/8" SMS

#8 X 5/8" SMS

MIN.EDGE DIST.

TYPICAL ANCHORSEE ELEVATION FOR SPACING

EXTE

RIO

R

CONCRETEf'c = 3000 psi MIN.

MIN.EDGE DIST.

TYPICAL ANCHORSEE ELEVATIONFOR SPACING

CONCRETEf'c = 3000 psi MIN.

DETAILD1A1

DETAILD1B1

5

D1

MIN

.EM

BED

.

MIN

.EM

BED

.

FRAM

E HEI

GHT

DETAIL

DETAIL

TYPICAL ANCHORSEE ELEVATION FOR SPACING

2"

2 1

3/1

6"

1/2

" SHIM

MAX.

9/1

6"

FRAM

E HEI

GHT

TYPICAL ANCHOR@ MTG. STILE, SEEELEVATION FOR SPACING

2 1

3/1

6"

2 1

3/1

6"

TYPICAL ANCHORSEE ELEVATIONFOR SPACING

TYPICAL ANCHOR@ MTG. STILE, SEEELEVATION FOR SPACING

1 3/4"

MIN

.EM

BED

.

4 1/2"1 3/4"

4 1/2"

APPLIED ONLY WHERE WATERINFILTRATION IS NOT REQUIRED.REFER TO NOTE #1 ON COVER SHEET.

Page 6: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

2 3

/16

"

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 126

D2

D2F DETAIL

TYPE 'A' -1/4" DIA. ITW TAPCON (Fu=120 KSI, Fy=92 KSI) W/ 1 1/2" MIN. EMBED INTO WOOD STRUCTURE OR THRU 1X OR 2X WOOD

BUCK W/ 1 1/2" MIN. EMBED INTO CONCRETE / MASONRY.

TYPE 'B' - 1/4" DIA. ELCO ULTRACON (Fu=177 KSI. Fy= 155 KSI) W/ 1 1/2" MIN. EMBED INTO WOOD STRUCTURE OR THRU 1X OR 2X WOOD

BUCK W/ 1 1/2" MIN. EMBED INTO CONCRETE / MASONRY.

TYPE 'C' - #14 SMS OR TEKS SELF DRILLING SCREW (GRADE 5) INTO METAL STRUCTURE.

SUBSTRATE: CONCRETE: f'c=3 KSI MIN. (HEAD/SILL OR JAMB) MASONRY: f'c= 2KSI MIN. (JAMB ONLY) WOOD: SG=0.55 MIN. (HEAD/JAMB)

STEEL: 1/8" MIN. THK., A36 MIN. (HEAD/JAMB)

TYPICAL EDGE DISTANCE:INTO CONCRETE/MASONRY: 2 1/2" MIN.INTO WOOD: 1" MIN.INTO METAL: 3/4" MIN.

TYPICAL ANCHORS:

MIN.EDGE DIST.

METAL STRUCTURE

1/8" MIN. THK.

1/2

" SHIM

MAX.

TYPICAL ANCHORSEE ELEVATIONFOR SPACING

MIN EDGEDIST.

2 BY WOOD BUCK ORWOOD STRUCTURE

MIN

.EM

BED

1/2

" MAX.

SHIM

MIN

.EM

BED

1/2

" MAX.

SHIM

MIN.EDDE DIST.

D2G DETAIL

2 3

/16

"D

.L.O

.

GLASS OPTIONS INTERCHANGEABLE.SEE SHEET G1 FOR GLASS OPTIONS.

EXTE

RIO

R

TYPICAL ANCHORSEE ELEVATIONFOR SPACINGTYPICAL ANCHOR

SEE ELEVATIONFOR SPACING

Page 7: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

SUBSTR

ATE

DETAILD3C DETAIL

D3D

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 12

D.L.O.

2" 2 11/16" 2 11/16" 2 13/16"

TYPICAL ANCHORSEE ELEVATION FOR SPACING

PERIMETER SEALANTALL AROUND FRAME

#8 X 5/8" SMS

#8 X 1" SMS

7

D3

SUBSTR

ATE

2"2 11/16"

PERIMETER SEALANTALL AROUND FRAME

#8 X 5/8" SMS

MIN

.ED

GE

DIS

T.

MIN.EMBED.

DETAILD3E

MIN

. ED

GE

DIS

T.

DETAILD3H DETAIL

D3I

2 3/16"2 3/16"

1/2" MAX.SHIM

1/2" MAX.SHIM

F.W.

GLASS OPTIONS INTERCHANGEABLE.SEE SHEET G1 FOR GLASS OPTIONS.

1/4" 1/8"3/16"

MIN.EMBED.

EXTERIOREXTERIOR

EXTERIOR

TYPICAL ANCHORSEE ELEVATION FOR SPACING

1 3

/4"

2 3

/8"

2 1

/2"

MEETING STILE OPTION

4 1

/2"

Page 8: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

APPROVED CONFIGURATIONS AND HARDWARE

OPTION 1LOCK:ACTIVE PANEL: VON DUPRIN MORTISE LOCK9975EO @ 39" FROM BOTTOM

SURFACE BOLTINACTIVE PANEL: IVES SB360ACTIVE PANEL: ABH HD1825ENGAGEMENT: 13/16" @ THRESHOLD AND 5/8" @FRAME HEAD.

FLUSH BOLT:INACTIVE PANEL: IVES 458ENGAGEMENT: 9/16" @ THRESHOLD AND FRAMEHEAD

DOOR CLOSER: ALLEGION LCN 4040 SERIES

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 12

0.2344

OPTION 2LOCK:ACTIVE PANEL: VON DUPRIN CVR 9947E0 PANICDEVICE W/ 2 POINT LOCK SYSTEM.

SURFACE BOLTS:ACTIVE PANEL: IVES SB360ENGAGEMENT: 13/16" @ THRESHOLD AND 9/16" @FRAME HEAD.

OPTION 3LOCK:ACTIVE PANEL: SCHLAGE L9453P SERIES MORTISELOCK AND DEADBOT

SURFACE BOLTS:INACTIVE PANEL: ABH SURFACE BOLTSACTIVE PANEL: IVES SB360ENGAGEMENT: 15/16" @ THRESHOLD AND 7/8" @FRAME HEAD.

OPTION 5LOCK:ACTIVE PANEL: DESIGN HARDWARE MORTISE LOCKAND DEADBOLT AT 39 1/4" FROM BOTTOM

SURFACE BOLT:INACTIVE PANEL: ABH HD1825ACTIVE PANEL: IVES SB360ENGAGEMENT: 13/16" @ THRESHOLD AND 9/16" @FRAME HEAD.

OPTION 6LOCK:ACTIVE PANEL: DESIGN HARDWARE CYLINDRICALLOCK Z SERIES AT 39 3/4" FROM BOTTOM

SURFACE BOLT:INACTIVE PANEL: IVES SB360 W/ ABH FLUSHBOLTSACTIVE PANEL: ABH HD1825ENGAGEMENT: 13/16" @ THRESHOLD AND 9/16" @FRAME HEAD.

FLUSH BOLTSINACTIVE: ABH 1855 @ 12" FROM ENDSENGAGEMENT: 9/16" @ THRESHOLD & HEAD.

OPTION 7LOCK:ACTIVE PANEL: SECURITECH EXIT PANIC DEVICE AT39" FROM BOTTOM

SURFACE BOLT:ACTIVE PANEL: IVES SB360INACTIVE PANEL: IVES SB360ENGAGEMENT: 13/16" @ THRESHOLD AND 5/8" ATFRAME HEAD

FLUSH BOLTSACTIVE PANEL: IVES 458ENGAGEMENT: 13/16" @ THRESHOLD AND 5/8" @FRAME HEAD.

8

HW1

OPTION 4LOCK:ACTIVE PANEL: DORMA MORTISE LOCK SL11HDWITH SURFACE MOUNT STRIKE PLATE

SURFACE BOLTS:INACTIVE PANEL: ABH SURFACE BOLTS HD1825ACTIVE PANEL: ABH SURFACE BOLTS HD1825ENGAGEMENT: 13/16" @ THRESHOLD AND 5/8" @FRAME HEAD.

ACTIVEINACTIVEACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVEINACTIVE INACTIVE

ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE ACTIVE INACTIVEINACTIVEINACTIVE

OPTION 8LOCK:ACTIVE PANEL: DORMA 9954MORTISE LOCK W/ LEVERHANDLE AND DEADBOLT @38" FROM BOTTOM

SURFACE BOLTS:ACTIVE PANEL: IVES SB360SURFACE BOLTSENGAGEMENT: 1/2" @THRESHOLD AND 13/16" @FRAME HEAD.

ACTIVE

Page 9: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

4.500"2

.00

0"

0.1

24

"

T-8 FRAME HEAD AND JAMB

1.743"

2.8

31

"0.060"

2.676"

1.7

43

"

1.2

45

"

0.0

62

"

2.756"

1.7

43

"

1.2

45

"

0.0

62

"

4.478"

0.9

65

"

0.1

34

"

0.1

39

"

1.743"

0.1

20

" 1.355" 1.350"

0.0

63

" 0.5

86

"

0.091"

1.3

09

"

383 MEETING STILE

1.618"

0.0

50

"

1.1

41

"

0.324"

0.036" 2.1

79

" 0.124"

39 DOOR SWEEP1

.74

3"

1.0

58

"

0.062"

0.9

96

"

0.0

63"

2.1

16

"

1.283"

1.2

12

"

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 12

1 70-2A TOP/BOTTOM RAIL2 70-1A FRAME HINGE STILE3 70-91A FRAME LOCK STILE4 561 THRESHOLD50

.62

2"

DS-33 DOOR STOP60

.15

5"

70-52 SWEEP STRIP BAR7

0.4

81

"

0.4

82

"

70-53 COVER CAP8 142 RAIN DRIP9 328 DOOR SEAL10

0.3

85

"

70-800 LITE KIT SNAP COVERALUM. 6063-T611 70-802 5/16" LITE KIT12

1.018"

29

1.2

45

"

1.3

83

"

0.194"

0.622"

123NA WATER SHED14

0.740"

124A WATER SHED15

141 RAIN DRIP16

0.994"

0.082"

1840 ASTRAGAL17

0.094"

189

PARTS

70-801 1" LITE KIT

1.021"

0.124"

2.1

88

"13

ALUM. 6063-T6

ALUM. 6063-T6 ALUM. 6063-T6

ALUM. 6063-T6

ALUM. 6063-T6 ALUM. 6063-T6

ALUM. 6063-T6 ALUM. 6063-T6

ALUM. 6063-T6

ALUM. 6063-T6

ALUM. 6063-T6 ALUM. 6063-T6 ALUM. 6063-T6 ALUM. 6063-T6

ALUM. 6063-T6 ALUM. 6063-T6 ALUM. 6063-T6 ALUM. 6063-T6

Page 10: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

SECTION A-AT8-CORNER DETAIL

#10 X 3/4" SMS

(3) #10 X 3/4" SMS

(2) #8 X 5/8" SMS

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 12

12.000"

0.375" 5.625" 5.625" 0.375"

1 1/4" X 1/2" X 12"LG. ALUM. BAR REINF.PT-8002 ALUM. 6061-T6411 1/4" X 1/2" X 12"LG. ALUM. BAR REINF.

PT-8001 ALUM. 6061-T640

12.000"

0.375" 5.625" 5.625" 0.375"

10

PARTS

CORNER CONNECTION DETAIL

10J

FRAME CORNER CLIP31

1.6

88

"

1.250"

0.1

25

"

0.2

50

"

1.2

50

"

1.2

50

"

ALUM. 6061-T6

Page 11: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 1211

B.O.M.

BILL OF MATERIALSITEM PART DESCRIPTION MATERIAL MANUFACTURER / REMARKS

1 T-8 2" X 4.5" CLASS 1 ANODIZED ALUMINUM HEAD/JAMB FRAME ALUM. 6063-T6 SPECIAL-LITE, INC.

2 70-2A TOP/BOTTOM RAIL ALUM. 6063-T6 SPECIAL-LITE, INC.

3 70-1A HINGE STILE ALUM. 6063-T6 SPECIAL-LITE, INC.

4 70-91A LOCK STILE ALUM. 6063-T6 SPECIAL-LITE, INC.

5 561 THRESHOLD ALUM. 6063-T6 ZERO INTERNATIONAL

6 DS-33 DOOR STOP ALUM. 6063-T6 SPECIAL-LITE, INC.

7 70-52 SWEEP STRIP BAR ALUM. 6063-T6 SPECIAL-LITE, INC.

8 70-53 COVER CAP ALUM. 6063-T6 SPECIAL-LITE, INC.

9 142 RAIN DRIP ALUM. 6063-T6 ZERO INTERNATIONAL

10 328 DOOR SWEEP W/ SOLID NEOPRENE ALUM. 6063-T6 & NEOPRENE ZERO INTERNATIONAL, ATTACHED W/ #6 X 1/2" SMS

11 70-800 LITE KIT SNAP COVER ALUM. 6063-T6 SPECIAL-LITE, INC.

12 70-802 LITE KIT 5/16" GLASS ALUM. 6063-T6 SPECIAL-LITE, INC.

13 70-801 LITE KIT 1" GLASS ALUM. 6063-T6 & NEOPRENE ZERO INTERNATIONAL, ATTACHED W/ #6 X 1/2" SMS

14 123NA WATER SHED ALUM. 6063-T6 NATIONAL GUARD

15 124A WATER SHED ALUM. 6063-T6 NATIONAL GUARD

16 141 RAIN DRIP ALUM. 6063-T6 ZERO INTERNATIONAL

17 1840 ASTRAGAL WITH NEOPRENE ALUM. 6063-T6 & NEOPRENE ZERO INTERNATIONAL

18 383 MEETING STILE WITH NEOPRENE ALUM. 6063-T6 & NEOPRENE ZERO INTERNATIONAL

19

- 0.120" PEBBLE FRP SKIN FRP SPECIAL-LITE, INC.

- - CRANE COMPOSITES

- 0.120" SANDSTONE FRP SKIN FRP SPECIAL-LITE, INC.

- - CRANE COMPOSITES

- AMP MASTERGRAIN

20 - POURED IN PLACE URETHANE FOAM OR EQUIVALENT URETHANE FOAM SPECIAL-LITE, INC.

21 RE-58 CORNER CLIP ALUM. 6061-T6 SPECIAL-LITE, INC.

22 RE-148 1 7/16" X 1 3/8" X 1/8" THK. X 47 5/8" LG. ALUM. CLIP REINFORCEMENT ALUM. 6061-T6 SPECIAL-LITE, AT TOP/BOTTOM RAIL

23 8634-5771-1 WEATHER STRIP POLYPROPOLENE & WOVEN PILE SCHLEGEL SYSTEMS

24 ZSP2110-002 RUBBER GASKET EPDM RUBBER TOTAL PLASTIC

25 - 38"-16 STEEL TIE ROD STEEL -

26 FMHD95AL CONTINUOUS HINGE ALUM. 6063-T6 DESIGN HARDWARE, (15) 1/4"-20 X 1/2" FH SMS ATTACHED TO FRAMEAND PANEL.

27 A110HD ABH CONTINUOUS HINGE ALUM. 6063-T6 ABH, (15) 1/4"-20 X 1/2" FH SMS ATTACHED TO FRAME AND PANEL.

28 PT-8003 1" X 0.855" X 16" LG. ALUMINUM BAR REINFORCEMENT ALUM. 6061-T6 (1) INSIDE THE THRESHOLD LOCATED AT 41" FROM LEFT.

29 39 DOOR SWEEP ALUM. 6063-T6 & NEOPRENE ZERO INTERNATIONAL

30 PT-519 EXTRUDED ALUMINUM REINFORCEMENT ALUM. 6061-T6 (1) INSIDE THE INACTIVE PANEL ABOVE AND BELOW EACH FLUSH BOLT.

31 PT-131 FRAME CORNER CLIP ALUM. 6061-T6 SPECIAL-LITE, INC.

32 PT-514 ONE EXTRUDED ALUMINUM BAR REINFORCEMENT ALUM. 6061-T6 INSIDE THE ACTIVE PANEL ABOVE AND BELOW THE LOCK

33 SL11HD DORMA MORTISE LOCK @ 39 3/4" FROM BOTTOM STEEL DORMA

35 PT-300 TWO-PIECE EXTRUDED ALUM. LOCK REINFORCEMENT ALUM. 6063-T6 (1) INSIDE THE ACTIVE PANEL LOCK STILE @ THE PANIC DEVICELOCATION.

36 PT-306 412" X 12" X 18" X 171

2" LG. ALUM. ANGLE REINFORCEMENT ALUM. 6063-T6(1) INSIDE THE LEFT SIDE OF THE LEFT PANEL TOP RAIL ON THE INT.

AND EXT. AND INSIDE THE RIGHT SIDE OF THE RIGHT PANEL TOP RAILON THE INT. AND EXT.

37 PT-304 ALUMINUM PLATE REINFORCEMENT ALUM. 6063-T6 (1) INSIDE THE HINGE STILE @ PANIC DEVICE LOCATION

0.0625" ALUM. SKIN

0.125" ALUMINUM SKIN

0.120" AMP SKIN

Page 12: SPECIAL-LITE, INC. ALUMINUM FRAME OUTSWING DOORS … · 2017-02-17 · february 15th, 2017 door note #1: units not approved for water infiltration must be installed at locations protected

February 15th, 2017

MC

Y E

NG

INE

ER

ING

, IN

C.

GL

AZ

ING

CO

NS

ULT

AN

TS

MC

Y

ALU

MIN

UM

FR

AME

OU

TSW

ING

DO

OR

S

OF 1212

B.O.M.

BILL OF MATERIALS (CONT.)ITEM PART DESCRIPTION MATERIAL MANUFACTURER / REMARKS

38 PT-317 TWO-PIECE EXTRUDED ALUM. LOCK REINFORCEMENT ALUM. 6063-T6 (1) INSIDE THE ACTIVE PANEL LOCK STILE @ THE PANIC DEVICE LOCATION.

39 PT-8000 ONE EXTRUDED ALUMINUM REINFORCEMENT ALUM. 6063-T6 INSIDE THE ACTIVE AND INACTIVE PANEL LOCK STILE AT TOP AND BOTTOM

40 PT-8001 114" x 12" x 12" LG. ALUMINUM BAR REINFORCEMENT ALUM. 6061-T6 (1) AT THE FRAME HEAD INSIDE THE DOOR STOP LOCATED 12" AND 91" FROM LEFT.

41 PT-8002 114" x 12" x 12" LG. ALUMINUM BAR REINFORCEMENT ALUM. 6061-T6 (1) AT THE FRAME HEAD INSIDE THE DOOR STOP, LOCATED AT 41" AND 611

2" FROM LEFT

42 9975EO MORTISE LOCK DEVICE @ 39" FROM BOTTOM STEEL VON DUPRIN, (2) 12"-24 X 1/2" F.H. SMS, (4) 10"-24 X 1" P.H. SMS & (2) 10"-24" X 1" F.H.SMS

43 SB360 IVES SURFACE BOLTS STEEL IVES, 6" FROM ENDS W/ (1) 2" X 1/2" X 7/8" ALUM. PLATE & (2) 1/4"-20 X 3" F.H. SMS

44 SC-1 6 X 38" PHILIPS F.H. SMS STEEL SPECIAL - LITE

45 SC-12 8 X 58" PHILIPS P.H. SMS STEEL -

46 SC-15 8 X 138" PHILIPS F.H. SMS STEEL -

47 SC-17 8 X 14" PHILIPS OVAL HEAD SMS STEEL -

48 SC-22 10 X 212" PHILLIPS F.H. SMS STEEL -

49 SC-23 10 X 34" PHILLIPS F.H. SMS STEEL -

50 SC-25 10 X 34" PHILLIPS TRUSS HEAD SMS STEEL -

51 SC-26 12-24 X 12" PHILLIPS U/C F.H. CLR STEEL -

52 SC-28 12-24 X 1" PHILLIPS F.H. CLR STEEL -

53 71TS1-F13E-630 SECURITECH EXIT DEVICE STAINLESS STEEL SECURITECH

54 9947EO SURFACE MOUNT METALLIC PANIC DEVICE ALUM. 6063-T6 VON DUPRIN

55 HD1825 ABH SURFACE BOLTS STAINLESS STEEL ABH

56 BB5 BALL BEARING HINGE @ 7 /1/2", 34 1/2", 62" & 88 3/4" FROM BOTTOM STEEL DESIGN HARDWARE, (4) 12"-24 X 1/2" F.H. SMS TO FRAME AND PANEL

57 SL-11HD SELECT PRODUCTS CONTINUOUS HINGE ALUM. 6063-T6 SELECT PRODUCTS

58 L9453P SCHLAGE L SERIES MORTISE LOCK AND DEADBOLT STEEL SCHLAGE

59 10-072 STRIKE STEEL -

60 Z-SERIES DESIGN HARDWARE CYLINDRICAL LOCK STEEL DESIGN HARDWARE

61 D2 DESIGN HARDWARE DEAD BOLT STEEL DESIGN HARDWARE

62 - SPACER ALUM. ALL METAL

63 - 1/8" SETTING BLOCK EPDM RUBBER,DURO 60 +/- 5 SHORE A ZATKOFF SEALS AND PACKING

64 - 1/4" SETTING BLOCK EPDM RUBBER,DURO 60 +/- 5 SHORE A GLAZING RUBBER PRODUCTS

65 9954 DORMA MORTISE LOCK AND DEADBOLT STEEL DORMA