8
SPECIFICATION PROJECT: - Grenfell Tower,London SPECIFIER: - Studio E Architects Issue No: - 001 Ref:- Technal Limited WICON.R: HBS Centre, Silkwood Park, Wakefield WF59TG Tel: Fax: www.wicona.co.uk Date: - 6th November 2013 Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG SEA00002422_0001 SEA00002422/1

SPECIFICATION - Grenfell Tower fire...BS EN 10268: Stainless steel. BS EN ISO 3506-1 Stainless steel screws BS EN 1774 & 12844: Zinc alloy castings BS EN 22063: Zinc spray BS EN 12540:

  • Upload
    others

  • View
    40

  • Download
    0

Embed Size (px)

Citation preview

  • SPECIFICATION

    PROJECT: - Grenfell Tower,London

    SPECIFIER: - Studio E Architects

    Issue No: - 001

    Ref:-

    Technal Limited

    WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tel: Fax: www.wicona.co.uk

    Date: - 6th November 2013

    Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0001 SEA00002422/1

  • l.GENERAL

    Aluminium profiles and accessories available from: -

    Wicona Silkwood Park Wakefield WF5 9TG

    Products:- WICLINE, WICSTYLE,, WICTEC

    WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tei:-Fax: www.wicona.co.uk

    Material data specifications- Aluminium alloy EN AW-6060 T66 (ALMgSi0,5 F22) DIN EN 573, DIN EN 755

    Ironmongery, accessories and fixing screws should be stainless steel, cadmium plated steel, or other corrosion resistant materials as supplied by Wicona.

    Glazing materials shall be Wicona's standard gaskets. Non-cellular sealing profiles DIN 7863. Sealing of glazing DIN 18545. Joints and glass sealing DIN 52460

    Materials can be polyester powder coated to BS6496 available in a large range of colours or anodised in accordance with BS EN 12373 - 1 or BS3987 in natural silver, bronze Anolok or in a

    variety of colours.

    The Technical Department within Wicona is able to provide specialist advice and technical information on the whole range of Wicona products and is fully equipped with up to date CAD Facilities. The team of Architectural Specification Managers is able to visit Architects & Specifiers to assist with development of designs and details regarding the glazed areas of buildings.

    Fabrication and installation of all Wicona products should be performed by a suitable Wicona fabricator/installer in accordance Wicona fabrication and installation manuals and must also be to recognised trade standards using approved design drawings.

    Double glazed sealed units glazed in accordance with BS6262 and Building Regulations. Single glazing can only be used where Building Regulations allow.

    Details of all the current Wicona systems are available from our websites on:-www.wicona.co.uk

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0002 SEA00002422/2

  • Genspec5 -August 2006

    WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tei:-Fax: www.wicona.co.uk

    (cont .... )

    2. Reference Documents for Aluminium Alloy Fenestration products: 854873: Aluminium windows & doors 855516: Sloping & vertical patent glazing 85 EN 13830 Curtain Walling (alternatively use CWCT specification)

    Aluminium EN AW-6060 T66 (ALMgSi0,5 F22)

    DIN EN 573, DIN EN 755

    Regulations and Standards Beside regional building regulations and guidelines, the standards and German contract conditions for metal construction work (VOB), glazing works, civil engineering and building physics of the latest respective issue are decisive. Valid and are respective current construction regulation list.

    Glass Statics DIN 1055-1 Effect on supporting framework DIN 1055 Design load for buildings, Part 2 up to 5 DIN 4113-1 Aluminium constructions mainly

    under static load; Calculation and Building design.

    BS 6399-2: Wind loading

    BS 6180: Barriers in and about buildings BS 7818: Pedestrian restraint systems BS 8118: Code of practice - Structu ra I use of

    aluminium. BS 8213-1: Code of Practice- safety in use

    cleaning BS EN 1026 Air permeability- Test method Part 1 windows and doors* BS EN 1027 Water tightness- Test method

    Part 1 windows and doors* BS EN 12211 Resistance to wind load- Test method* BS EN 12207 Air permeability- Requirement Classification Part 1 Windows & Doors** BS EN 12208 Water tightness- Requirement Classification Part 1 Windows & Doors** BS EN 12210 Resistance to wind load-Classification. Part 1 Windows and doors** BS 6375 -1 weather tightness classification*** BS 6375- 2 Operation & strength characteristics**

    Doors

    BS 8300: Design of buildings and their approaches to meet the need of disabled people. BS DD 171: Guide to specifying performance requirements for hinged or pivoted doors. BS 7036: Safety at powered doors for pedestrian use BS EN 1125: Building hardware- panic exit devices operated by horizontal bar BS EN 179: Building hardware- panic exit

    devices operated by lever handles or push pad

    Materials

    BS EN 12020: Aluminium alloys, extruded profiles. BS EN 573- 3: aluminium alloys, chemical composition. BS EN 515: Aluminium alloys, temper designation. BS EN 485: Aluminium alloys, sheet. BS EN 755: Aluminium alloys, extrusion. BS 4255-1: Gaskets. BS 4254: Polysulphide, 1 part. BS 5215: Polysulphide, 2 part. BS 5889: Silicone sealant

    Glass

    BS 5713: Hermetically sealed flat double glazed units** BS EN 572-1: Glass in building (soda lime

    silicate glass)* BS EN 1063: Security glazing (resistance to bullet attack) BS EN 356: Security glazing (resistance against manual attack) BS 6206: Safety glass specification BS 6262: Glass in buildings BS 6262: Part 4 Safety relating to human impact *see also BS 952 **see also BS EN 1279

    Other aspects

    BS 6100: Glossary of building terms.

    BS EN 12373: Anodising BS 3987: Anodising BS 4842: Liquid organic coatings BS 6496: Powder organic coatings

    PD 6484: Commentary on corrosion of bi-

    metallic contacts and its alleviation BS7950 Specification for enhanced security performance of casement and tilt/turn windows for domestic applications BS 8213-4: Code of Practice for installation of

    replacement windows and doors BS 7950: Enhanced security performance for casement windows; domestic applications. BS 8220-1/-2/-3: Guides for the security of buildings against crime. BS EN 1670: Building hardware corrosion resistance BS EN 10268: Stainless steel. BS EN ISO 3506-1 Stainless steel screws BS EN 1774 & 12844: Zinc alloy castings BS EN 22063: Zinc spray BS EN 12540: Electra plate, nickel BS 3382: Electra plate, screws. BS EN 12329 & 12330: Electra plate coatings. BS 6338: Chromate coating. BS 7479: Salt spay test. BS EN ISO 1461 Hot dip galvanized coatings on fabricated iron & steel articles. Specifications and test methods

    Quality control

    BS EN ISO 9000: Quality management systems

    BS 8000-5/-7/-16: Codes of practice for workmanship on site

    N.B. This list is not exhaustive but covers those documents which are most frequently used. These may not necessarily be a requirement of the specification nor may the product be covered by the requirements of the documents referred to European regulations are continually changing so if further information or clarification is required, please refer to Technal. For a more complete summary of reference documents please see Technal publication TCAPlO

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0003 SEA00002422/3

  • 3. NBS Specification

    Hll CURTAIN WALLING

    To be read with Preliminaries/General conditions. TYPE(S) OF CURTAIN WALLING

    110 CURTAIN WALLING: [WICONA WICTEC 50] Drawing reference(s):

    WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tel: Fax: www.wicona.co.uk

    Supporting structure: STEELWORK AT HEAD, INTERMEDIATE FIXING POINTS STEEL OR FLOOR SLABS & CONCRETE CILL OR STEEL Curtain walling system: Manufacturer and reference: Wicona, HBS Centre, Silkwood Park, Wakefield, WF5 9TG Phone:- Fax:-Type: - [WICTEC 50]]

    To include all products, fixings and interfaces necessary to complete the fabrication and installation. Performance criteria to comply with Design/Performance Requirements and Testing subsections. Internal framing member: Material: [Aluminium Alloy 6063T6 to BS1474] Finish: [Polyester Powder Coated BS6496] Colour/texture: [Standard RAL Colour] Minimum film thickness: [60 microns] External cover cap: Material: [Aluminium Alloy 6063T6 to BS1474] Finish: : [Polyester Powder Coated BS6496] Colour/texture: [Standard RAL Colour] Minimum film thickness [ 60 microns] Glazing: [Double glazed sealed units to conform to parts K, M, & N of the building regulations and to achieve a U value to meet part L2 of the building regulations, based on energy model calculations] Inner pane: 6mm Toughened HST with Low E coating to face #3 [1n accordance with Building Regulations including Document Land BS6180 where applicable] Cavity: [Black warm edge technology spacer, argon filled cavity] Outer pane: 6mm Toughened HST[In accordance with Building Regulations including Document Land BS6180 where applicable] Panel/facing type: [Double glazed spandrel panels (standard colour) with insulation contained with in a foil or aluminium tray] Inner pane: 6mm Toughened HST with ceramic frit to face #4 [1n accordance with Building Regulations including Document Land BS6180 where applicable] Cavity: [Black warm edge technology spacer]

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0004 SEA00002422/4

  • WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tel: Fax: www.wicona.co.uk

    Outer pane: 6mm Toughened HST[In accordance with Building Regulations including Incorporated components: [ Spandrel area can also be metal faced insulated panel specification to be agreed] Other requirements: []

    DESIGN/PERFORMANCE REQUIREMENTS

    340 AIR PERMEABILITY: Permissible air leakage rates of 1.5 cu m/hr/sq m for fixed lights and 2.0 cu m/hr/lin.m for opening lights must not be exceeded when the curtain walling is subjected to a peak positive test pressure of [600] Pascals.

    350 WATER PENETRATION onto internal surfaces or into cavities not designed to be wetted must not occur when the curtain walling is subjected to a peak positive test pressure of [600] Pascals.

    PRODUCTS

    710 ALUMINIUM ALLOY FRAMING SECTIONS: To BS 1474, alloy 6063 or similar approved and suitable for the specified finish. Structural members to comply with BS 8118.

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0005 SEA00002422/5

  • LlO WINDOWS/ROOFLIGHTS/SCREENS/LOUVRES

    To be read with Preliminaries/General conditions. PRELIMINARY INFORMATION/REQUIREMENTS

    WICON.R: HBS Centre,

    Silkwood Park, Wakefield WF59TG

    Tei:-Fax: www.wicona.co.uk

    110 EVIDENCE OF PERFORMANCE: Provide independently certified evidence that all specified variants of components comply with specified performance requirements.

    120 SITE DIMENSIONS must be taken and recorded on shop drawings before starting to manufacture products.

    COMPONENTS

    330 ALUMINIUM WINDOWS: [WICONA] Drawing reference(s): [] Manufacturer and reference: [Wicona, HBS Centre, Silkwood Park, Wakefield, WF5 9TG Phone:- Fax:-Type: - [WICLINE 65 evo, WICLINE 75 evo]

    Exposure category (Design site wind pressure): [1200] (Pa). Glazing: [Double glazed sealed units to conform to parts K, M, & N of the building regulations and to achieve a U value to meet part L2 of the building regulations, based on energy model calculations] Inner pane: 8.8 laminated [with LowE coating to face #31n accordance with Building Regulations including Document Land BS6180 where applicable] Cavity: [Black warm edge technology spacer, argon filled cavity] Outer pane: 6mm Toughened HST [In accordance with Building Regulations including Document Land BS6180 where applicable] Panel/facing type: [Double glazed spandrel panels (standard colour) with insulation contained with in a foil or aluminium tray] Ironmongery/accessories: [WICSTAR DPS (Direct Positioning System), concealed]

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0006 SEA00002422/6

  • WICON.R:

    Finish: [Polyester powder painted 60 microns]

    HBS Centre, Silkwood Park,

    Wakefield WF59TG

    Tei:-Fax: www.wicona.co.uk

    Fixing: [Stainless steel screws or other corrosion resistant materials] Other requirements: [ ]

    670 Brise Soleil: [WICONA] Drawing reference(s): [] Manufacturer and reference: Wicona, HBS Centre, Silkwood Park, Wakefield, WFS 9TG Phone:- Fax:-----

    Type: - Wicsolaire Solar shading system

    WicsolaSuneal is designed to reduce glare and solar heat gain on the building. Configuration of the blades is determined by the orientation and geometry of the building, the wind load, snow load, height of the building and the aesthetic requirements of the CA.

    Blade Type: External to side hung open in windows, with perimeter frame fixed to outer vent frame, blade size and spacing to be agreed; Orientation; Horizontal Fixing: Mechanical fixing to substructure of windows Movement: Fixed blades

    Materials: ALUMINIUM ALLOY BLADE & SUPPORT SECTIONS: To BS 1474, alloy 6063 or similar approved and suitable for the specified finish. Structural members to comply with BS 8118.

    Finish as delivered: Polyester powder painted to standard RAL colour, minimum 60 microns Fixings: Fixings as recommended by Wicona from standard range Accessories: Other requirements: []

    L20 DOORS/SHUTTERS/HATCHES

    To be read with Preliminaries/General conditions.

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0007 SEA00002422/7

  • WICON.R:

    PRELIMINARY INFORMATION/REQUIREMENTS

    HBS Centre, Silkwood Park,

    Wakefield WF59TG

    Tei:-Fax: www.wicona.co.uk

    110 EVIDENCE OF PERFORMANCE: Provide independently certified evidence that all specified variants of components comply with specified performance requirements.

    150 SITE DIMENSIONS must be taken and recorded on shop drawings before starting to manufacture products.

    COMPONENTS

    280 ALUMINIUM DOORS AND FRAMES: [WICONA] Drawing reference(s): [] Manufacturer and reference: [Wicona, HBS Centre, Silkwood Park, Wakefield, WF5 9TG Phone:- Fax:- ] Type:- [WICSTYLE 65, WICSTYLE 75]

    Glazing: [Double glazed sealed units to conform to parts K, M, & N of the building regulations and to achieve a U value to meet part L2 of the building regulations, based on energy model calculations] Inner pane: 8.8 laminated with low E coating to face #3 [1n accordance with Building Regulations including Document Land BS6180 where applicable] Cavity: [Black warm edge technology spacer, argon filled cavity] Outer pane: 6mm toughened HST[In accordance with Building Regulations including Document Land BS6180 where applicable] Finish as delivered: [Polyester powder painted to standard RAL colour, minimum 60 microns] Ironmongery: [WICSTAR DPS (Direct Positioning System)] Other requirements: [ RC2 security rating ironmongery ,locks and fittings to be agreed]

    Note:- The above Specification is based on the information available at the time it was prepared and it may be necessary to vary the sections proposed if a full installation survey or further design amendments show this to be necessary. The size and strength of any sections included must be checked by the selected fabricator as no liability can be accepted by Technal if these prove to require amendment.

    Technal Limited Registered in England No. 1420752 Registered Office: HBS Centre, Silkwood Park, Wakefield WF5 9TG

    SEA00002422_0008 SEA00002422/8