6
Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer resolu6on UltraBright No slit, just a giant aperture and a huge field of view. 100x more light UltraOSA 200x faster than a regular OSA www.lightmachinery.com Spectrometers UltraRaman for measuring high resolu6on Raman spectra

Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

Hyperfinefor measuring hyperfine spectra. 1 picometer resolu6on

Brillouin HyperFine with ac6ve pump suppression

Hornetfor laser characteriza6on, 30 picometer resolu6on

UltraBrightNo slit, just a giant aperture and a huge field of view. 100x more light

UltraOSA200x faster than a regular OSA

! www.lightmachinery.com

Spectrometers

UltraRaman for measuring high resolu6on Raman spectra

Page 2: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

HyperFine

Part Number Spectral RegionTotal Range (nm)

with manual gra-ng rota-on without gra-ng rota-onResolu8on (pm)

Simultaneous Range (nm)

HyperFine Spectrometer

HF-8993-1

HF-8989-1

HF-8989-2

HF-8989-2e

HF-8995-2

HF-8991-3

HF-8995-1

HF-8989-3

UV

VIS

VIS

VIS

NIR

NIR

NIR

VIS

270 - 330

400 - 500

500 - 600

525 - 640

900 - 1100

800 - 1000

700 - 900

600 - 700

25

15

15

15

20

20

25

15

2.5

1.0

1.0

1.0

2.0

2.0

2.0

1.0

Notes

• Range and resolu.on are measured at the middle of the wavelength range• Accuracy: < 20pm following calibra.on, an external calibra.on source is required• Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracke.ng• Simultaneous range / resolu.on: >10,000 at 532nm• Acquisi.on speed: >10Hz typical

Op-ons

• Etalon for bright source characteriza.on (lasers), VIPA etalon for high throughput is standard• MMF input with a 10um slit, SMF input with no slit is standard• Low resolu.on mode, covers the total range with 0.2nm resolu.on

Camera op-ons

• CMOS for laser characteriza.on, passive element characteriza.on, Brillouin, Raman and solar spectroscopy• CCD for low light applica.ons (non -scanning of Brillouin biological samples)• Scien.fic CMOS for low light applica.on requiring fast acquisi.on• ICCD for applica.ons requiring ga.ng (LIBS)• UV C-MOS with good quantum efficiency down to 260nm

! www.lightmachinery.com

Page 3: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

Brillouin HyperFine

! www.lightmachinery.com

Specifica(ons Resolu(on (pm)

Part number

Wavelength range

Spectral resolu5on

Pump wavelength filter suppression

Weight

Dimensions

USB 3.1

Filter input

Dynamic range (at 6GHz from pump)

Pump suppression filter width

Pump suppression filter tunability

HF-8999-532-AUTO

530.5nm to 533.5nm

1pm

>30dB

25kg

71 x 37 x 15 cm

>1A required

SMF only

>75 dB

0.5pm

+/- 1nm

Brillouin HyperFine Spectrometer HF-8999-532-GK-AUTO

Page 4: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

Hornet

Hornet Spectrometer HF-9352

Specifica/ons

• Resolu0on: sub 20pm at 532nm (resolving power > 25,000)

• Accuracy: < 200pm following calibra0on, an external calibra0on source is required

• Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracke0ng

• Wavelength range: Visible to near IR (260nm to 1080nm*)

• Simultaneous range / resolu0on: >10,000 at 532nm

• Acquisi0on and processing speed: >10 Hz

Part Number Spectral Region Wavelength Range (nm) Resolu:on (pm)

HN-9340

HN-9332

HN-9353

HN-9354

HN-9352

UV

Visible

NIR

1um Lasers

Visible & IR

260 - 425

425 - 700

700 - 1050

1010 - 1080

YAG, (532 and 1064)+/-10

15 - 30

15 - 30

25 - 40

10

15

! www.lightmachinery.com

Page 5: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

UltraRaman/UltraBright

UltraRaman Spectrometer UR-9342

UltraBright Spectrometer

Specifica4ons

• Resolu/on: sub 30pm at 532nm (resolving power > 20,000)

• Accuracy: < 200pm following calibra/on, an external calibra/on source is required

• Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracke/ng

• Cooled CCD Camera

• Simultaneous range / resolu/on: >10,000 at 532nm

• Acquisi/on and processing speed: >10 Hz

Part Number Spectral Region Wavelength Range (nm) Resolu:on (pm)

UR-9340

UR-9332

UR-9353

UV

Visible

NIR

260 - 425

425 - 700

700 - 1050

<30

<30

<40

Specifica4ons

• Resolu/on: sub 0.5nm at 532nm

• Acquisi/on and processing speed: >10 Hz

Part Number Spectral Region Wavelength Range (nm) Resolu:on (nm)

UR-10559

UR-10849

UV (LIBS)

Visible

220 - 340

590 - 750

0.3

0.5

! www.lightmachinery.com

Page 6: Spectrometers · Hyperfine for measuring hyperfine spectra. 1 picometer resolu6on Brillouin HyperFine with ac6ve pump suppression Hornet for laser characteriza6on, 30 picometer

UltraOSA

UltraOSA Spectrometer HF-8990-1

Specifica1ons• High sensi0vity InGaAs camera• Acquisi0on and processing 0me: <25 msecs for the complete spectrum • Con0nuous Spectra at 40Hz• Resolu0on: sub 50pm at 1550nm (resolving power > 30,000 to >300,000)• Simultaneous range / resolu0on: >2000 at 1550nm• Accuracy: based on an external calibra0on source is required• Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracke0ng • Wavelength range: NIR (1260nm to 1675nm)

Part Number Spectral Region Wavelength Range (nm) Resolu:on (pm)

UO-10785-HRO

UO-10785-URO

UO-10790-URU

UO-10790-HRU

UO-10789-URL

UO-10789-HRL

UO-10788-URC

UO-10788-HRC

UO-10788-LRCL

UO-10787-URS

UO-10787-HRS

UO-10786-URE

UO-10786-HRE

O Band

O Band

U Band

U Band

L Band

L Band

C Band

C Band

C & L Band

S Band

S Band

E Band

E Band

1260 - 1360

10 within 1260 - 1360

10 within 1626 - 1675

1625 - 1675

10 within 1565 - 1625

1565 - 1625

10 within 1530 - 1565

1530 - 1565

1525 - 1650

10 within 1460 - 1530

1460 - 1530

10 within 1360 - 1460

1360 - 1460

40

4

4

20

4

24

4

15

50

4

30

4

40

! www.lightmachinery.com