PUMPS
PUMPSHANDBOOK
For your local branch please telephone
0845 603 3363
...WE’RE
GREENER,CLEANERANDLEANER
SPEEDY PUMPS MINIMISE ENVIRONMENTAL DAMAGE & MAXIMISE FUEL ECONOMY.Our customers have cut their fuel bills by up to 50% whilst seeing a dramatic increase in pump efficiency. Long run fuel tankswith a double bunded design prevent spillage on site, helping to protect the environment and reduce running costs.
Simple design for guaranteed performance!
To find out more Lo-call:
0845 603 3363www.speedyhire.co.uk
...PRESERVING THE ENVIRONMENT
ContentsIntroduction 4
Health & Safety 8
Section 1 Diesel Range 12
Section 2 Electric Surface Range 22
Section 3 High Head Range 24
Section 4 Electric Submersible Drainage 32
Section 5 Electric Submersible Sewage 38
Section 6 Control Panels, Pressure Test Pumps and Specialist Pumps 43
Section 7 Air Operated Pumps 46
Accessories 48
Reference Data 51
Trouble Shooting Guide 58
Branch Locations 62
Within this publication Speedy Pumps have described a range of products which are offered for hire subject to availability. However, circumstances maylead us to offering alternative equipment, all of which are leading brands and have passed our exhaustive product selection criteria. Whilst every care andattention has been taken to describe the equipment fleet in detail, customers are advised to check with our experienced staff at the time of hire.
Working in partnership with leading suppliers:
Speedy has revolutionised the large pumps market with a multi-million pound investment in a brand new range of state-of-the-art, high performance pumps – available for immediatedelivery from our nationwide network of dedicated pump depots.
Included in the range are:
• 3"-12" liquidator diesel pumps
• 3"- 8” high head diesel pumps
• Air pumps and hydraulics
• Submersible electric pumps – sewage & drainage
• Starter panels
• Hoses and accessories
All our pumps are super-silent, environmentally friendly andextremely fuel efficient. We pride ourselves on our ability to workwith customers to provide solutions to even the most complex ofprojects, offering 24/7 back-up and an emergency call-out service.
Welcome to Speedy Pumps...
Expert guidance and exceptional coverage,whenever and wherever you need it!
For further information on our full range of pumps please con
Benefits and features as standard include:
• Super-silent – ideal for residential andnoise sensitive locations
• No spillage on-site – designed specificallywith an integrated drip tray and fuel bund
• Extremely fuel efficient – leanburn engineminimises environmental damage andmaximises fuel economy
• All current standards are met ensuring noadditional costs
• Fast road tow or skid mounted
• Simple to set up and operate
• Self priming & clog free operation – ensuredthrough twin blade spiral flow impeller
• Full canopy design with bunded base toprotect against weather and vandalism
• Safety features and telemetry connection
• Security tracking system (on request)
• Spark arrestors – fitted as standard
• Chalwin valve – fitted as standard
• 24/7 emergency response
• Free site surveys and demonstrations
No.1 forPUMPSNewest fleet of pumps in theindustry
Emergency cover 24/7
Extremely fuelefficient
Environmentallyfriendly
...setting new standards in pump hire
ntact your nearest Speedy Pumps depot on 0845 603 3363
WELCOMEIN
TROD
UCTI
ON6
All pumps available for immediate delivery
A Specialist Business with Group Backing
Speedy Pumps is part of Speedy Hire Plc, the UK and Ireland’s most progressive tool and equipment hire organisation.
As part of Speedy Hire we benefit from phenomenal Groupbuying power and pass this benefit on to our customersthrough extremely competitive pricing.
• 4 acquisitions in 2006
• £263 million of equipment for hire
• £115 of million investment in products last year
• 3,500 helpful, informed and highly motivated staff
• Over 1,000 delivery vehicles
We pride ourselves on the strength of our customerrelationships; we are both a local supplier offering a quick,friendly service through any one of over 300 branches and we are a supply chain partner offering nationalagreements and customised services.
NOISE AT WORK
7
Nationwide network of dedicated pump depots
New regulations, introduced in 2006, haveseen a reduction in the daily exposure tonoise levels:
• Lower Exposure Action Value reduced to 80db (or135db peak sound pressure)
• Upper Exposure Action Value reduced to 85db (or 137db peak sound pressure)
• Exposure Limit Value reduced to 87db (or 140db peaksound pressure)
The legislation requires that:
• Noise assessments are to be undertaken by a competentperson if the noise level exceeds the first action level
- Details on how to undertake an assessment can be found atwww.hse.gov.uk/noise/noise.htm
• Noise reduction measures are implemented wherereasonably practicable
• Workers are provided with appropriate training and information
• Appropriate PPE and hearing tests are provided if there is evidence of a risk to workers’ hearing
• The risks posed by noise are eliminated or reduced wherever it is reasonably practicable to do so
Speedy Hire is actively striving to assist in the area of noise at work.
• Speedy pioneered the reference to manufacturers’decibel figures in our catalogue. Please note: decibelfigures are for guidance only and will vary depending onenvironmental conditions
• Our purchasing policy is to buy super-silencedequipment wherever practical
• We provide suitable PPE equipment, as required,including ear plugs and heavy duty ear protectors
• Speedy have developed a flyer to help you to raisethe awareness of noise at work. Copies are available, at no cost by calling UK 0845 606 6886 / ROI 1850 812 100.
Noise at work
RECOMMENDEDREADING
If you need to know more aboutNoise at Work, Speedy Hirerecommend the following furtherreading from the Health & SafetyExecutive:
INDG362 - Revision 1 - Noise atWork Guidance (download FOC from the HSE website).
L108 -Controlling Noise at Work ISBN 0-7176-6164-4. Can bepurchased from HSE Books.
Excessive and continuous exposure to noise can cause long-term damage to hearing, but the effects are preventable
WELCOMEHE
ALTH
& S
AFET
Y8
Quietest pumps in the market
NO.1 FOR SAFETY
Speedy Pumps is committed to Health & Safety for both ouremployees and customers. Our industry leading Health & Safety policy guides everything we do. It’s part of oureveryday working practice, not just a written policy.
Safe Hire AwardSpeedy was the first national hire organisation to be awarded the prestigious Safe-HIRE Award by the Hire Association of Europe.
Audits• Depot Managers complete a 25 point check every week• Regional Safety Audits carried out monthly and approved by
Regional Directors• Scheduled and unscheduled audits are carried out by
Speedy Health & Safety Officers• Information collated and analysed monthly, then reported
and discussed at each Board Meeting• KPIs on Health & Safety compiled and then reviewed at the
Group Operating Board Meeting
The Hire• Products supplied from the most modern fleet in
the industry• Safe products such as low vibration, super-silenced, and
zone-one approved are available• Safety leaflets are provided with every hire• Proof of safety inspection is provided either through the safety
inspection checklist being an integral part of the contractitself, or through the inspection number being on both theequipment and the contract
• Finally, staff check you have all the necessary PPE
Mystery Shoppers• A permanent team of mystery shoppers are employed
to provide totally independent feedback of our customer service
• As part of every visit the mystery shoppers complete an 8 point Health & Safety checklist, and the equipment theyhire is sent to a workshop for independent examination
HEALTH & SAFETY
9WELCOME
Simple to operate pumps
Training
• Customer training can be arranged for all products in theSpeedy Hire range
• Excellence in Training Award 2002 (Hire Association of Europe)
• Staff training covers induction training through to all aspectsof equipment repair and inspection
• Bespoke courses are developed to cover specificcustomers’ needs
• Courses approved by associations including PASMA and St Johns’ Ambulance
• For more information call our Training Team on0845 8502 300
Health & Safety Management
• The Speedy Hire Health & Safety group meets every twomonths to review the Health & Safety policy in light ofrecent events including accidents, near misses, trends, newlegislation, etc
• Group members include the Health & Safety team as wellas other department heads
• The Health & Safety group is represented on the SpeedyHire group operating board
Safety Information for Pump users
Any item of plant or equipment can be dangerous if not used correctly. If, at any time, you require additionalinformation or training please do not hesitate to call yournearest Speedy Pumps Depot (see page 62) where we wouldbe happy to demonstrate the safest way to operate any of our hired equipment.
WELCOMEHE
ALTH
& S
AFET
Y10
UK’s largest fleet of environmentally friendly pumps
As the hirer, please read the following key safety points beforeoperating any equipment:
Risk Assessment
There is a duty on employers under current Health & Safetylegislation to adopt best practice measures to reduce risk andensure the Health & Safety of themselves, co-workers and the public.
Testing
In line with the Health & Safety Executive requirements,submersible pumps will have to be checked for earthconductivity and resistance on a 90-day cycle. This may resultin Speedy requiring access to the equipment whilst on hire.
Special Safety Devices
Do not disable or adjust any safety or protective device fitted tothe pump or increase any governed speed or workingpressures in the pump.
Exhaust Gases
Do not operate equipment in confined spaces without goodventilation. Breathing exhaust gases is dangerous and couldpotentially kill.
Sparks & Fire
Explosions and fire can be caused by sparks from exhaust orelectrical systems. Do not use machines in a closed areawhere there is flammable material, vapour or dust.
Hot Surfaces
Whilst the pump is in normal operation do not touch any ofthe engine components including the exhaust, pump ends,valves and tanks. Surfaces get extremely hot and can burn.
HEALTH & SAFETY
11WELCOME
Super-silent pumps
Hydraulic Fluid
To check for hydraulic fluid leaks hold a piece of cardboardclose to suspected leaks and then inspect for fluid. Do not usebare hands – fine jets of hydraulic fluid at high pressure canpenetrate the skin. Always wear eye protection. If fluid comesinto contact with eyes or flesh seek medical help immediately.
Oil
Do not handle used engine oil more than necessary as itcontains harmful contaminants which can cause skin cancer.Always use barrier cream or wear gloves to prevent skincontact. Avoid contact with the mouth.
Damaged Hoses & Cables
Damaged hoses and cables can cause fatal accidents. Inspectregularly for:
• Damaged end fittings / loose glands
• Chafed outer covers or exposed wire armour
• Ballooned outer covers
• Kinked or crushed hoses
• Embedded armouring in outer covers
Electrical Control Equipment
Earth leakage protective devices and motor overloads shouldonly be adjusted by a competent person.
Safety Symbols
*Safety gloves and protective footwear should always be wornwhen handling pumps and/or any ancillary equipment.
SECTION 1 DIESEL RANGEDI
ESEL
RAN
GE12
Auto start & telemetry panels available on all the diesel range
The liquidator range of pumps are state-of-the-art assemblies,not modified old designs. Included in the range are 3''-12''(75mm to 300mm) diesel pumps, fast road tow or skidmounted and all silenced so ideal for residential and noisesensitive locations as well as being fully compliant with new‘Noise at Work’ regulations.
GSP 50SILENCED DIESEL
13SECTION 1DIESEL RANGE
Emergency cover 24/7
SPECIFICATIONMax Capacity 51m3/hrPort Size 2" (50mm)Total Head 30mSuction Lift 9mOperating Speed 3000 rpmSolids Size 28mmImpeller Type Open VaneWeight 82kgDimensions Length 940mmWidth 640mmHeight 600mmdBA @7m 75Run Time 5hrsFuel Consumption per hour 0.6 LTank Size 3 L
Product Code 0012
SECTION 1 DIESEL RANGEGS
P 11
5SSI
LENC
ED D
IESE
L14
Auto start & telemetry panels available on all the diesel range
SPECIFICATIONMax Capacity 115m3/hrPort Size 3" (75mm)Total Head 19mSuction Lift 9mOperating Speed 1500 rpmSolids Size 75mmVacuum Pump Capacity 30cfmImpeller Type ChannelWeight (Wet No Trailer) 580kgWeight (Wet with Trailer) 645kgDimensions (excl Trailer) (inc Trailer)Length 1200mm 2200mmWidth 600mm 1200mmHeight 1000mm 1300mmdBA @7m 66Run Time 20hrsFuel Consumption per hour 1.5 LTank Size 30 LStandard Strainer G.P. Intake
Shown with emergency response undercarriage (Skid mounted units available)
Product Code 0290
QL 100SILENCED DIESEL
15SECTION 1DIESEL RANGE
All pumps available for immediate delivery
SPECIFICATIONMax Capacity 186m3/hrPort Size 4" (100mm)Total Head 23.5mSuction Lift 8.8mOperating Speed 1500 to 2000 rpmSolids Size 40 dia. x 65mmVacuum Pump Capacity 65cfmImpeller Type Open Spiral Vane Weight (Without fuel) 1098EF / 1133EV kgWeight (Max) 1288EF / 1328EV kgDimensions Length 3970EF / 4272EV mmWidth 1600mmHeight 1927mmdBA @7m 70Run Time 49hrsFuel Consumption per hour 3.1 LTank Size 220 L
Product Code 0300
SECTION 1 DIESEL RANGEQL
150
SILE
NCED
DIE
SEL
16
Auto start & telemetry panels available on all the diesel range
SPECIFICATIONMax Capacity 345m3/hrPort Size 6" (150mm)Total Head 20.5mSuction Lift 8.5mOperating Speed 1500 to 2000 rpmSolids Size 65 dia. x 80mmVacuum Pump Capacity 65cfmImpeller Type Open Spiral Vane Weight (Without fuel) 1123EF / 1158EV kgWeight (Max) 1313EF / 1348EV kgDimensions Length 3970EF / 4272EV mmWidth 1600mmHeight 1927mmdBA @7m 70Run Time 42hrsFuel Consumption per hour 5 LTank Size 220 L
Product Code 0305
QL 200SILENCED DIESEL
17SECTION 1DIESEL RANGE
Nationwide network of dedicated pump depots
SPECIFICATIONMax Capacity 540m3/hrPort Size 8" (200mm)Total Head 33.5mSuction Lift 9mOperating Speed 1500 to 2000 rpmSolids Size 75 dia x 90mmVacuum Pump Capacity 65cfmImpeller Type Open Spiral Vane Weight (Without fuel) 1242EF / 1277EV kgWeight (Max) 1432EF / 1467EV kgDimensions Length 4040EF / 4342EV mmWidth 1600mmHeight 1927mmdBA @7m 73Run Time 33hrsFuel Consumption per hour 6.6 LTank Size 220 L
Product Code 0307
SECTION 1 DIESEL RANGEGS
P 30
0SI
LENC
ED D
IESE
L18
Auto start & telemetry panels available on all the diesel range
SPECIFICATIONMax Capacity 176m3/hr
Port Size 4" (100mm)
Total Head 29m
Suction Lift 9.1m
Operating Speed 1800 rpm
Solids Size 65mm
Vacuum Pump Capacity 95cfm
Impeller Type Twin Blade
Weight (Wet No Trailer) 1150kg
Weight (Wet with Trailer) 1470kg
Dimensions (excl Trailer) (inc Trailer)Length 2300mm 4000mm
Width 1000mm 1680mm
Height 1250mm 1550mm
dBA @7m 59
Run Time 38hrs
Fuel Consumption per hour 2.75 L
Tank Size 105 L
Standard Strainer G.P. Intake
Product Code 0300
Shown with emergency response undercarriage(Skid mounted units available)
GSP 340SILENCED DIESEL
19SECTION 1DIESEL RANGE
Quietest pumps in the market
Shown with emergency response undercarriage(Skid mounted units available)
SPECIFICATIONMax Capacity 340m3/hrPort Size 6" (150mm)Total Head 28mSuction Lift 9.1mOperating Speed 1800 rpmSolids Size 75mmVacuum Pump Capacity 95cfmImpeller Type Twin BladeWeight (Wet No Trailer) 1220kgWeight (Wet with Trailer) 1520kgDimensions (excl Trailer) (inc Trailer)Length 2300mm 4000mmWidth 1000mm 1680mmHeight 1250mm 1550mmdBA @7m 59Run Time 32hrsFuel Consumption 3.25 LTank Size 105 LStandard Strainer G.P. Intake
Product Code 0305
SECTION 1 DIESEL RANGEGS
P 65
0SI
LENC
ED D
IESE
L20
Auto start & telemetry panels available on all the diesel range
SPECIFICATIONMax Capacity 650m3/hrPort Size 8" (200mm)Total Head 35mSuction Lift 9.1mOperating Speed 1800 rpmSolids Size 82mmVacuum Pump Capacity 95cfmImpeller Type Twin BladeWeight (Wet No Trailer) 1600kgDimensions (excl Trailer)Length 2800mmWidth 1115mmHeight 1600mmdBA @7m 65Run Time 10hrsFuel Consumption 17 LTank Size 170 LStandard Strainer G.P. Intake
Product Code 0307
GSP 1200SILENCED DIESEL
21SECTION 1DIESEL RANGE
Simple to operate pumps
SPECIFICATIONMax Capacity 1200m3/hrPort Size 12" (300mm)Total Head 42mSuction Lift 9.1mOperating Speed 1800 rpmSolids Size 90mmVacuum Pump Capacity 95cfmImpeller Type Twin BladeWeight (Wet No Trailer) 1800kgDimensions (excl Trailer)Length 3000mmWidth 1200mmHeight 1600mmdBA @7m 65Run Time 8hrsFuel Consumption 28 LTank Size 230 LStandard Strainer G.P. Intake
Product Code 0309
SECTION 2 ELECTRIC SURFACE RANGEES
P 30
0EL
ECTR
IC P
UMPS
22
Emergency cover 24/7
SPECIFICATIONMax Capacity 165m3/hrPort Size 4" (100mm)Total Head 27mVoltage 415v 3 phaseMotor 11kWHz 50Suction Lift 9mStarter Auto/TransOperating Speed 1450 rpmSolids Size 65mmVacuum Pump Capacity 95cfmImpeller Type Twin BladeWeight (Dry) 410kgDimensionsLength 2300mmWidth 1000mmHeight 1250mmStandard Strainer G.P. IntakeGenerator Size 30kVA
Product Code 0054
ESP 340ELECTRIC PUM
PS23SECTION 2ELECTRIC SURFACE RANGE
Newest fleet of pumps in the industry
SPECIFICATION
Max Capacity 310m3/hrPort Size 6" (150mm)Total Head 25mVoltage 415v 3 phaseMotor 15kWHz 50Suction Lift 9mStarter Auto/TransOperating Speed 1450 rpmSolids Size 75mmVacuum Pump Capacity 95cfmImpeller Type Twin BladeWeight (Dry) 480kgDimensionsLength 2300mmWidth 1000mmHeight 1250mmStandard Strainer G.P. IntakeGenerator Size 30kVA
Product Code 0055
SECTION 3 HIGH HEAD RANGEHI
GHHE
ADRA
NGE
24
All pumps available for immediate delivery
High Head Automatic Priming Pumps
Speedy’s Automatic pumps are designed for applications wherea high lift is required.
These will include mines and quarries and major works such astunnels and deep foundations.
Design Features
• Skid mounted, open set or super-silent, all with integral fuel tank
• 12 volt battery starting by key switch
• Pump will pass solids up to 32mm diameter
• Reliable double mechanical seals which allow dry running.Optional spring assisted pressure seal
• Pump can be left running when liquid is exhausted and willprime automatically when liquid is present
• Rugged construction requires minimal operator maintenance
• 25cfm vacuum pump with coalescer and air exhaust toatmosphere
• Pump will run on load for 21 hours before refuelling
• Chalwyn valves and spark arrestors fitted as standard
QHH80
SUPER SILENT HIGH HEAD25SECTION 3HIGH HEAD RANGE
Nationwide network of dedicated pump depots
SPECIFICATIONMax Capacity 120m3/hrPort Size 3" (80mm)Total Head 89mSuction Lift 8.3mOperating Speed 2000 to 2400 rpmSolids Size 18 mm dia.Vacuum Pump Capacity 65cfmImpeller Type Open Twin Vane Weight (Without fuel) 1123EF / 1157EV kgWeight (Max) 1313EF / 1348EV kgDimensions Length 3970EF / 4272EV mmWidth 1600mmHeight 1927mmdBA @7m 77Run Time 25hrsFuel Consumption per hour 8.8 LTank Size 220 L
Product Code 0051
SECTION 3 HIGH HEAD RANGEGH
P 80
SUPE
R SI
LENT
HIG
H HE
AD26
Quietest pumps in the market
Product Code 0051 SPECIFICATIONMax Capacity 100m3/hrPort Size Inlet 3" (75mm)
Outlet 3" (75mm)Total Head 95mSuction Lift 9mOperating Speed 1800 rpmMax Speed 2500 rpmSolids Size 25mmMax Absorbed Power 30kWVacuum Pump Capacity 30cfmImpeller Type 4 Vane ClosedWeight (Wet No Trailer) 1400kgDimensions (excl Trailer)Length 2300mmWidth 1000mmHeight 1250mmdBA @7m 65Run Time 24hrsFuel Consumption per hour 7 L(At max engine Speed)Tank Size 170 L
GHP 100SUPER SILENT HIGH HEAD
27SECTION 3HIGH HEAD RANGE
Simple to operate pumps
SPECIFICATION
Max Capacity 175m3/hrPort Size Inlet 4" (100mm)
Outlet 3" (75mm)Total Head 110mSuction Lift 9mOperating Speed 1800 rpmMax Speed 2500 rpmSolids Size 32mmMax Absorbed Power 68kWVacuum Pump Capacity 30cfmImpeller Type 5 Vane ClosedWeight 2810kgWidth 1200mmHeight 1900mmdBA @7m 65Run Time 14hrsFuel Consumption per hour 21 L(At max engine Speed)Tank Size 300 L
Product Code 0052
SECTION 3 HIGH HEAD RANGEGH
P 15
0SU
PER
SILE
NT H
IGH
HEAD
28
Super-silent pumps
SPECIFICATION
Max Capacity 430m3/hrPort Size Inlet 6" (150mm)
Outlet 4" (100mm)Total Head 115mSuction Lift 9mOperating Speed 1800 rpmMax Speed 2200 rpmSolids Size 42mmMax Absorbed Power 130kWVacuum Pump Capacity 30cfmImpeller Type 5 Vane ClosedWeight 3680kgWidth 1200mmHeight 1900mmdBA @7m 65Run Time 7.5hrsFuel Consumption per hour 39 L(At max engine Speed)Tank Size 350 L
Product Code 0053
GHP 200SUPER SILENT HIGH HEAD
29SECTION 3HIGH HEAD RANGE
UK’s largest fleet of environmentally friendly pumps
SPECIFICATION
Max Capacity 580m3/hrPort Size Inlet 8" (150mm)
Outlet 6" (100mm)Total Head 158mSuction Lift 9mOperating Speed 1500 rpmMax Speed 1800 rpmSolids Size 47mmMax Absorbed Power 230kWVacuum Pump Capacity 30cfmImpeller Type 5 Vane ClosedWeight 2500kgDimensions Length 5000mmWidth 1500mmHeight 2000mmdBA @7m 67Run Time 4.5hrsFuel Consumption per hour 63 L(At max engine Speed)Tank Size 350 L
Product Code 0057
SECTION 3 HIGH HEAD RANGEHH
150
SUPE
R SI
LENT
HIG
H HE
AD30
Emergency cover 24/7
SPECIFICATIONMax Capacity 600m3/hrPort Size Inlet 8" (200mm)
Outlet 6" (150mm)Total Head 100mSuction Lift 9mOperating Speed 1200 to 2100 rpmMax Speed 2100 rpmSolids Size 32 dia. mmMax Absorbed Power 105kWVacuum Pump Capacity 65cfmImpeller Type Open Twin Vane Weight (Without fuel) 2295kgWeight (Max) 2600kgDimensions Length 2909mmWidth 1590mmHeight 2246mmdBA @7m 96Run Time 21hrsFuel Consumption per hour 19 L(At max engine Speed)Tank Size 400 L
Product Code 0059
31
Newest fleet of pumps in the industry
SAFESET
Track, Trace and Alert Fuel Management Maintenance Reports Performance Log Movement Violation Internet Access
Protect your company from theimpact of plant and equipment theft
“SAVE £££s ON INSURANCE PREMIUM COSTS”
Theft of on-site machinery is a growing problem, with over £100 million worth ofequipment stolen in the UK alone every year. The scale of the problem is driving upinsurance premiums for thousands of firms who fall victim each year and are forced tosubmit claims to recover costs.
To combat this Speedy developed SAFESET®, a revolutionary asset tracking andmanagement system, unique to the hire market. The ‘box’ is wireless and small enoughto conceal in any piece of high value equipment.
Proactive action allows for immediate savings with insurance companies typically offeringpremium discounts of up to 25% on hired equipment fitted with a tracking device.
With a proven 98% recovery rate on stolen equipment (compared to a nationalaverage of just 5%), we are confident SAFESET® can save you both time and money.
Secure the advantage: To request our SAFESET® literature, please call: UK 0845 603 3363 / ROI 01 830 1087
“REDUCE LOST TIME DUE TO EQUIPMENT FAILURE”
Performance monitoring
SAFESET® is not just a tracking and recovery device, our advanced technology allows thesystem to wirelessly monitor signals from the machine it is protecting.
This means that we can provide valuable information such as running time, low fuel and oilchange to reduce running and servicing costs.
With a proven 98% recovery rate on stolen equipment, SAFESET® can save you money on insurance premiums and limitlost productivity through downtime.
PROVEN BENEFITS:• Proven 98% recovery rate• Save £££s on insurance premiums• Pin-point the location of hired equipment at any time
via the web• Real time movement violation via S.M.S.• Unique fuel management system• Service scheduling and management reports• Monitor efficiency from anywhere in the world
SAFESET - PERFORMANCE
TRACKING SYSTEM
SECTION 4 ELECTRIC SUBMERSIBLE DRAINAGEIN
TROD
UCTI
ON32
Newest fleet of pumps in the industry
Submersibles - Drainage & Sewage
Speedy’s new range of submersible pumps represent a majorbreakthrough in de-watering pump technology offering optimumperformance and ease of use.
Submersible pumps available for de-watering of constructionsites, mines, draining of flooded areas and other similarapplications where the liquid may contain abrasive particles.
FS 750DRAINAGE SUBM
ERSIBLE33SECTION 4ELECTRIC SUBMERSIBLE DRAINAGE
Emergency cover 24/7
SPECIFICATIONMotor 0.75kWVoltage 110vHose Size 2" (50mm)Nominal Speed 2850 rpmRunning Amps 10DimensionsWidth 179mmHeight 359mmWeight 15kgFlowrate 20m3/hHead 15mCable Length 20mGenerator Size 5kVA
Product Code 0141
SECTION 4 ELECTRIC SUBMERSIBLE DRAINAGEFS
322
DRAI
NAGE
SUB
MER
SIBL
E34
Super-silent pumps
Product Code 0149 SPECIFICATIONStandard High head
Motor 2.2kW 2.2kWVoltage 400v 400vHose Size 3" (75mm) 3" (75mm)Nominal Speed 2850 rpm 2850 rpmStarter DOL DOLRunning Amps 5.7 5.7DimensionsWidth 215mm 215mmHeight 460mm 460mmWeight 40kg 40kgFlowrate 46m3/hr 31m3/hrHead 20m 28mCable Length 30m 30mGenerator Size 20KVA 20kVA
FS 437DRAINAGE SUBM
ERSIBLE35SECTION 4ELECTRIC SUBMERSIBLE DRAINAGE
All pumps available for immediate delivery
SPECIFICATIONStandard High head
Motor 3.7kW 3.7kWVoltage 400v 400vHose Size 4" (100mm) 4" (100mm)Nominal Speed 2850 rpm 2850 rpmStarter DOL DOLRunning Amps 9.5 9.5DimensionsWidth 285mm 285mmHeight 497mm 497mmWeight 50kg 50kgFlowrate 90m3/hr 61m3/hrHead 20m 42mCable Length 30m 30mGenerator Size 20KVA 20kVA
Product Code 0154
SECTION 4 ELECTRIC SUBMERSIBLE DRAINAGEJ2
05DR
AINA
GE S
UBM
ERSI
BLE
36
Nationwide network of dedicated pump depots
Product Code 0156 SPECIFICATIONMotor 22kWVoltage 400vHose Size 6" (150mm)Nominal Speed 2930 rpmStarter Auto
TransformerRunning Amps 39DimensionsWidth 572mmHeight 970mmWeight 155kgFlowrate 360m3/hrHead 31mCable Length 30mGenerator Size 30kVA
BS2250DRAINAGE SUBM
ERSIBLE37SECTION 4ELECTRIC SUBMERSIBLE DRAINAGE
Quietest pumps in the market
SPECIFICATION
Motor 56kWVoltage 400vHose Size 10'' (300mm)Nominal Speed 1450 rpmStarter Auto TransformerRunning Amps 110DimensionsWidth 960mmHeight 1130mmWeight 525kgFlowrate 1260m3/hrHead 30mCable Length 30m Generator Size 140kVA
Product Code 0159
SECTION 5 ELECTRIC SUBMERSIBLE SEWAGEGS
S 08
31SE
WAG
E SU
BMER
SIBL
E38
Simple to operate pumps
SPECIFICATION
Power at Shaft 2.2kWPower from Mains 2.88kWHose Size 3'' (75mm)Voltage 400vNominal Speed 1450 rpmStarter DOLDischarge 80mmRunning Amps 5.15Cable Length 20m Cable Type Individually screenedDimensionsLength x Width 411mm x 233mmHeight 560mmWeight 78kgFlowrate 90m3/hrHead 11mSolids 75mmGenerator Size 20kVA
Product Code 0116
GSS 1031SEW
AGE SUBMERSIBLE
39SECTION 5ELECTRIC SUBMERSIBLE SEWAGE
UK’s largest fleet of environmentally friendly pumps
SPECIFICATION
Power at Shaft 3kWPower from Mains 3.95kWHose Size 4'' (100mm)Voltage 400vNominal Speed 1450 rpmStarter DOLDischarge 100mmRunning Amps 7Cable Length 20m Cable Type Individually screenedDimensionsLength x Width 411mm x 233mmHeight 580mmWeight 80kgFlowrate 115m3/hrHead 10.1mSolids 100mmGenerator Size 20kVA
Product Code 0117
SECTION 5 ELECTRIC SUBMERSIBLE SEWAGEGS
S 15
43SE
WAG
E SU
BMER
SIBL
E40
Super-silent pumps
SPECIFICATION
Power at Shaft 18.5kWPower from Mains 20.73kWHose Size 6'' (150mm)Voltage 400vNominal Speed 1450 rpmStarter Auto TransformerDischarge 150mmRunning Amps 35.65Cable Length 30m Cable Type Individually screenedDimensionsLength x Width 581mm x 498mmHeight 802mmWeight 227kgFlowrate 390m3/hrHead 33mSolids 100mmGenerator Size 30kVA
Product Code 0118
GSS 2045SEW
AGE SUBMERSIBLE
41SECTION 5ELECTRIC SUBMERSIBLE SEWAGE
Newest fleet of pumps in the industry
SPECIFICATIONPower at Shaft 18.5kWPower from Mains 20.73kWHose Size 8'' (200mm)
10'' (250mm)Voltage 400vNominal Speed 1450 rpmStarter Auto TransformerDischarge 200mmRunning Amps 35.65Cable Length 30m Cable Type Individually screenedDimensionsLength x Width 689mm x 569mmHeight 825mmWeight 266kgFlowrate 650m3/hrHead 25mSolids 125mmGenerator Size 30kVA
Product Code 0119
SECTION 5 ELECTRIC SUBMERSIBLE SEWAGETO
YODP
50 H
EAVY
DU
TY D
REDG
ING
PUM
P42
Emergency cover 24/7
SPECIFICATION
Outlet 150mmCapacity 190m3/hrManom Head 25mGrain Size 60mmPower 37kWRPM 980HzCurrent 75vElectric Cable 4 x 35mmWeight 950kg
Toyo DP submersible agitator pumps have beendesigned for stirring up and mixing into suspensionabrasive components such as sand, gravel, stones and similar debris and then transferring it overconsiderable distances.
They are ideal for a wide range of dredging, mineralextraction and industrial cleaning operations. All wearingparts such as agitator, impeller and adjustable wear platesare manufactured from special high chrome steel, forlong service life.
AUTO-CONTROL SYSTEMS
43SECTION 6STARTER / CONTROL PANELS
Extremely fuel efficient
SPECIFICATION
• IP54 Zintex panel finished to company colour
• Load break door interlocked isolator
• Dol starter
• Ralspeed special wide ranging overload unit to protectdifferent size pumps
• Earth leakage protection
• Hand / auto switch
• Door mounted alphanumeric keypad showing run & tripconditions and also containing – stop / reset-start buttons,hand or auto leds, running led and flashing tripped led
• Door mounted emergency stop (also to terminals)
• Thermistor or klixon trip circuit
• Analogue output related to motor current
• Inter-panel interlock system
• Lifting hook
• Motor & control connections wired to terminals
• 12VDC control for floats
• 24VAC power supply customer use
The Heart of the Panel
• Unique wide ranging overload
• Simple kilowatt selection willset up the overload protection
• Built in earth leakage
• Thermistor connections
Digital Display
• Kilowatt selected
• Running amps
• Hand, auto, running andtripped LED
• Start and stop push button
• Last eight fault history
Two versions available:1kW-13.5kW 18.5kW-55kW
SECTION 6 PRESSURE TEST PUMPSDI
ESEL
FIL
L 'N
' TES
TPR
ESSU
RE T
EST
PUM
PS44
Emergency cover 24/7
SPECIFICATION
Speed 1,500 rpmPressure Range 15 - 1500psiDimensionsWidth 650mmHeight 640mmDry Weight 105kgFlow Range 12gpm - 3gpm
Electric start pump
5m of 1" suction hose with a fine strainer
5m of 3/4" 500psi delivery hose with a BSP male connection and a quick release fitting at the pump
Can also be used as a pressure washer
N/B The customer will be required to supplyand fit their own test gauge and relief valve
Product Code 0405
BENTONITE PUMP
45SECTION 6SPECIALIST PUMPS
Newest fleet of pumps in the industry
Bentonite Pump
The state-of-the-art Bentonite pump has been designedspecifically for bentonite duties with ease of use in mind.Specifically designed so that it can be easily accessed anddismantled by hand for easy cleaning.
Features include:
• Super-silent
• High capacity long run diesel tank ensuring high pump efficiency
• Fast road tow
• Lightweight
• Full canopy design with bunded base to protect againstweather and vandalism
B50 2" - Air Operated Diaphragm Pump
Metallic Series
• Air valve designed for in-line maintenance
• End ported for improved flow
• Pressures to 8.6 bar
• Flow rates up to 530 litres/minute
• Bolted construction for greater integrity
• Robust construction
SECTION 7 AIR OPERATED PUMPSB5
0AI
R OP
ERAT
ED P
UMPS
46
All pumps available for immediate delivery
Product Code 0041
B50
general shot ofproducts in use- can’t get
B75/AP50AIR OPERATED PUM
PS47AIR OPERATED PUMPS
Nationwide network of dedicated pump depots
SECTION 7
AP50 - Submersible Centrifugal Pump
Suitable for the following industries: mining, construction,de-watering, sewage, well-pointing.
• Submersible
• Designed for underground use
• High intensity, spark free
• Robust construction
• Modular construction, easy to maintain
• Spring loaded vanes for immediate start-up
• Pumps solid particles up to 8mm
• Viton seal options for higher temperatures
• Integral baseplate/strainer
• Automatic overspeed control
• Integral oil reservoir - automatic lubrication
B75 3" - Air Operated Diaphragm Pump
Metallic Series
• Air valve will not stall in mid position
• Air valve designed for in-line maintenance
• End ported for improved flow
• Pressures to 8.6 bar
• Flow rates up to 889 litres/minute
• Bolted construction for greater integrity
• Robust construction
Product Code 0042
B75
Product Code 0009
AP50
HOSESAC
CESS
ORIE
S48
Quietest pumps in the market
TYPE SIZELayflat 2" - 8"
Poly Hose 2" - 8"
Flanged Wire Armoured 3" - 8"
Wire Armoured 2" - 12"
Galvanised Steel Pipe 3" - 12"
Flanged Steel Pipe 6" - 10"
Specialist Hoses 2" - 8"
High Pressure Hoses 2" - 8"
ACCESSORIES49SETTLEMENT & SEPARATION TANK
Simple to operate pumps
SPECIFICATION
Dimensions:Length: 2150mmWidth: 1150mmHeight: 1500mmWeight (Dry): 450kgCapacity (with 6" fittings): 1500 Gallons
With authorities and organisations such as theEnvironment Agency stipulating the prevention of siltand solids being discharged into sewers andwatercourse, our Separator Tanks are designed tomaintain pumping capacity whilst avoiding thesepotential problems.
DRIP TRAYSAC
CESS
ORIE
S50
UK’s largest fleet of environmentally friendly pumps
Speedy Pumps offer a full range of drip trays for a variety of applications.
• Environmental protection for open set diesel pumps
• Bleed valves for the safe discharge of contaminatedcontents from the tray
• Various sizes available to suit all sizes of diesel pumps
REFERENCE DATA51FLOW ESTIMATES
Super-silent pumps
Flow Estimates
Flow meters are available for this purpose. In addition the following simple tests can be used. The pipe should be straight, at least1.5m (5ft) from the nearest elbow, bend or valve. The rate of flow can be estimated from the distance 'X' or 'Y'. For larger pipesthe flow is proportioned to pipe diameter squared (full pipe only).
Distance Bore and Gallons per minute
'x' 2" 3" 4" 5" 6" 8"
6" 20 47 88 134 237 433
8" 26 61 111 190 277 520
10" 32 73 132 206 350 600
12" 45 96 150 260 377 700
15" 48 109 196 309 520 900
20" 64 148 265 512 703 1200
Distance Bore and Gallons per minute
'Y' 4" 6" 8" 10" 12" 18"
Just Full 230 640 1280 2250 3480 83001/4 down 137 385 760 1340 2100 47801/2 down 66 188 370 650 1000 21503/4 down 20 92 110 200 300 550
HEAD & FLOW CONVERSION TABLESRE
FERE
NCE
DATA
52
Newest fleet of pumps in the industry
510
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170180
190
200
210220
230
240
250260
270
280
m /h i gpm i gphI/minI/sec
20
30
35
40
45
50
55
60
65
70
75
15
10
200 502,0004,000
6,0008,000
10,000
12,000
16,00014,000
18,000
20,000
24,00022,000
26,000
28,000
32,00030,000
34,000
36,000
40,00038,000
42,000
44,000
48,00046,000
50,000
52,000
56,00054,000
60,00058,000
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1,000
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
25
3
HEAD CONVERSION TABLE FLOW CONVERSION TABLE
REFERENCE DATA53FRICTION LOSS CHARTS
Emergency cover 24/7
1GPM 2' 3' 4' 6' 8' 10' 12' m3/hr
50 10 1.5 0.4 10
75 20 3 0.8 15
100 35 5 1 0.1 20
150 12 2.5 0.35 30
200 18 4.5 0.6 50
300 40 10 1.2 0.4 75
400 18 2.2 0.7 100
500 28 3.5 1.1 0.4 125
600 38 4.5 1.5 0.5 150
700 6.5 2 0.7 175
800 8 2.7 0.8 200
900 10 3.4 1 0.4 225
1000 13 4 1.4 0.5 250
1200 18 6 2 0.8 300
1400 26 8 3 1 350
1600 32 11 4 1.5 400
1800 36 14 4.5 2 450
2000 38 17 5 2.5 500
2500 25 9 4 650
3000 38 12 5 750
4000 21 8 1 000
5000 32 13 1250
Losses in MTR/100 MTR or ft/100 ft of pipe
Note: M3/H x 4 = GPM Approx. The above is a rough guide.i.e. 10% less flow reduces by 20%. Large pipes conserve energy.
FLANGE CONVERSION CHARTSRE
FERE
NCE
DATA
54
Extremely fuel efficient
Dimensions and details of availability for BS 4504-1969 flanges on request. BS 10 BS 1560/ASA flanges are available as screwed, slip-on, welding neck and other patterns
TABLE D TABLE E
Nominal Actual bore Dia of Dia of No of Dia/Length Thickness Dia of Dia of No of Dia/Length Thickness
Bore of Flange Flange Bolt Circle Bolts of Bolts of Flange Flange Bolt Circle Bolts of Bolts of Flange
mm inch inch inch inch inch inch inch inch inch inch
15 1⁄2 7⁄8 33⁄4 2 5⁄8 4 1⁄2 X 11⁄2 3⁄16 3 3⁄4 25⁄8 4 1⁄2 X 11⁄2 1⁄4
20 3⁄4 1 3⁄32 4 2 7⁄8 4 1⁄2 X 11⁄2 3⁄16 4 27⁄8 4 1⁄2 X 11⁄2 1⁄4
25 1 1 3⁄8 41⁄2 3 1⁄4 4 1⁄2 X 11⁄2 3⁄16 4 1⁄2 31⁄4 4 1⁄2 X 11⁄2 9⁄32
32 11⁄4 1 23⁄32 43⁄4 3 7⁄16 4 1⁄2 X 11⁄2 1⁄4 4 3⁄4 37⁄16 4 1⁄2 X 11⁄2 5⁄16
40 11⁄2 1 15⁄16 51⁄4 3 7⁄8 4 1⁄2 X 11⁄2 1⁄4 5 1⁄4 37⁄8 4 1⁄2 X 11⁄2 11⁄32
50 2 2 7⁄16 6 4 1⁄2 4 5⁄8 X 2 5⁄16 6 41⁄2 4 5⁄8 X 2 3⁄8
65 21⁄2 3 1⁄16 61⁄2 5 4 5⁄8 X 2 5⁄16 6 1⁄2 5 4 5⁄8 X 2 13⁄32
80 3 3 9⁄16 71⁄4 5 3⁄4 4 5⁄8 X 2 3⁄8 7 1⁄4 53⁄4 4 5⁄8 X 2 7⁄16
90 31⁄2 4 1⁄16 8 6 1⁄2 4 5⁄8 X 2 3⁄8 8 61⁄2 8 5⁄8 X 2 15⁄32
100 4 4 9⁄16 81⁄2 7 4 5⁄8 X 21⁄4 3⁄8 8 1⁄2 7 8 5⁄8 X 21⁄4 1⁄2
125 5 5 9⁄16 10 8 1⁄4 8 5⁄8 X 21⁄4 1⁄2 10 81⁄4 8 5⁄8 X 21⁄2 9⁄16
150 6 6 9⁄16 6 11⁄16 11 9 1⁄4 8 5⁄8 X 21⁄4 1⁄2 11 91⁄4 8 5⁄8 X 21⁄2 11⁄16
175 7 7 23⁄32 12 10 1⁄4 8 5⁄8 X 21⁄4 1⁄2 12 101⁄4 8 5⁄8 X 21⁄2 3⁄4
200 8 8 23⁄32 131⁄4 11 1⁄2 8 5⁄8 X 21⁄2 1⁄2 13 1⁄4 111⁄2 8 3⁄4 X 3 3⁄4
225 9 923⁄32 141⁄2 12 3⁄4 8 5⁄8 X 21⁄2 5⁄8 14 1⁄2 123⁄4 12 3⁄4X 3 13⁄16
250 10 10 7⁄8 16 14 8 3⁄4 X 21⁄2 5⁄8 16 14 12 3⁄4 X 3 7⁄8
300 12 12 7⁄8 18 16 12 3⁄4 X 211⁄2 3⁄4 18 16 12 7⁄8 X 31⁄2 1
REFERENCE DATA55FLANGE CONVERSION CHARTS
All pumps available for immediate delivery
TABLE F TABLE HNominal Actual bore Dia of Dia of No of Dia/Length Thickness Dia of Dia of No of Dia/Length ThicknessBore of Flange Flange Bolt Circle Bolts of Bolts of Flange Flange Bolt Circle Bolts of Bolts of Flangemm inch inch inch inch inch inch inch inch inch inch
15 1⁄2 7⁄8 3 3⁄4 2 5⁄8 4 1⁄2 X 11⁄2 3⁄8 41⁄2 31⁄4 4 5⁄8 X 2 1⁄2
20 3⁄4 1 3⁄32 4 2 7⁄8 4 1⁄2 X 11⁄2 3⁄8 41⁄2 31⁄4 4 5⁄8 X 2 1⁄2
25 1 1 3⁄8 4 3⁄4 3 7⁄16 4 5⁄8 X 13⁄4 3⁄8 43⁄4 37⁄16 4 5⁄8 X 2 9⁄16
32 11⁄4 1 23⁄32 5 1⁄4 3 7⁄8 4 5⁄8 X 2 1⁄2 51⁄4 37⁄8 4 5⁄8 X 21⁄4 11⁄16
40 11⁄2 1 15⁄16 5 1⁄2 4 1⁄8 4 5⁄8 X 2 1⁄2 51⁄2 41⁄8 4 5⁄8 X 21⁄4 11⁄16
50 2 2 7⁄16 6 1⁄2 5 4 5⁄8 X 21⁄4 5⁄8 61⁄2 5 4 5⁄8 X 21⁄2 3⁄4
65 21⁄2 3 1⁄16 7 1⁄4 5 3⁄4 8 5⁄8 X 21⁄4 5⁄8 71⁄4 53⁄4 8 5⁄8 X 21⁄2 3⁄4
80 3 3 9⁄16 8 6 1⁄2 8 5⁄8 X 21⁄4 5⁄8 8 61⁄2 8 5⁄8 X 23⁄4 7⁄8
90 31⁄2 4 1⁄16 8 1⁄2 7 8 5⁄8 X 21⁄2 3⁄4 81⁄2 7 8 5⁄8 X 3 7⁄8
100 4 4 9⁄16 9 7 1⁄2 8 5⁄8 X 3 3⁄4 9 71⁄2 8 5⁄8 X 31⁄2 1
125 5 5 9⁄16 11 9 1⁄4 8 3⁄4 X 3 7⁄8 11 91⁄4 8 3⁄4 X 31⁄2 11⁄8
150 6 6 9⁄16 611⁄16 12 10 1⁄4 12 3⁄4 X 3 7⁄8 12 101⁄4 12 3⁄4 X 31⁄2 11⁄8
175 7 7 23⁄32 13 1⁄4 11 1⁄2 12 3⁄4 X 31⁄2 7⁄8 131⁄4 111⁄2 12 3⁄4 X 31⁄2 11⁄4
200 8 8 23⁄32 14 1⁄2 12 3⁄4 12 3⁄4 X 31⁄2 1 141⁄2 123⁄4 12 3⁄4 X 4 11⁄4
225 9 9 23⁄32 16 14 12 7⁄8 X 31⁄2 11⁄8 16 14 12 7⁄8 X 4 13⁄8
250 10 10 7⁄8 17 15 12 7⁄8 X 31⁄2 11⁄8 17 15 12 7⁄8 X 4 13⁄8
300 12 12 7⁄8 19 1⁄4 17 1⁄4 16 7⁄8 X 31⁄2 11⁄4 191⁄4 171⁄4 16 7⁄8 X 41⁄2 15⁄8
Dimensions and details of availability for BS 4504-1969 flanges on request. BS 10 BS 1560/ASA flanges are available as screwed, slip-on, welding neck and other patterns
FLANGE CONVERSION CHARTSRE
FERE
NCE
DATA
56
Nationwide network of dedicated pump depots
NOMINAL PRESSURE RATING (N.P.6) 6 BAR
Nominal Flange Table 6/2 Table 6/3 Table 6/4 Table 6/5 Table 6/8 Raised Face Pitch Number SizeSize Outside Forged Plate Forged Forged Plate Diameter Thickness Circle of of Bolts
Diameter Welding Slip-on Bossed Bossed Blank Diameter BoreholesNeck Screwed Slip-on
Thickness Thickness Thickness Thickness Thicknessmm mm mm mm mm mm mm mm mm mm metric
15 80 12 12 12 12 12 40 2 55 4 M10 x 40
20 90 14 14 14 14 14 50 2 65 4 M10 x 45
25 100 14 14 14 14 14 60 2 75 4 M10 x 45
32 120 14 16 14 14 14 70 2 90 4 M12 x 45
40 130 14 16 14 14 14 80 3 100 4 M12 x 45
50 140 14 16 14 14 14 90 3 110 4 M12 x 45
65 160 14 16 14 14 14 14 3 130 4 M12 x 45
80 190 16 18 16 16 16 128 3 150 4 M16 x 55
100 210 16 18 16 16 16 148 3 170 4 M16 x 55
125 240 18 20 18 18 18 178 3 200 8 M16 x 60
150 265 18 20 18 18 18 202 3 225 8 M16 x 60
200 320 20 22 - 20 20 258 3 280 8 M16 x 60
250 375 22 24 - 22 22 312 3 335 12 M16 x 65
300 440 22 24 - 22 22 365 4 395 12 M20 x 70
All thickness dimensions shown include the raised face. Where the raised face is not applicable, in the case of blank flanges, the 2mm spigot thickness is not included.
REFERENCE DATA57FLANGE CONVERSION CHARTS
Quietest pumps in the market
NOMINAL PRESSURE RATING (N.P.16) 16 BAR
Nominal Flange Table 6/2 Table 6/3 Table 6/4 Table 6/5 Table 6/8 Raised Face Pitch Number SizeSize Outside Forged Plate Forged Forged Plate Diameter Thickness Circle of of Bolts
Diameter Welding Slip-on Bossed Bossed Blank Diameter BoreholesNeck Screwed Slip-on
Thickness Thickness Thickness Thickness Thicknessmm mm mm mm mm mm mm mm mm mm metric
15 95 14 14 14 14 14 45 2 65 4 M12 x 45
20 105 16 16 16 16 16 58 2 75 4 M12 x 50
25 115 16 16 16 16 16 68 2 85 4 M12 x 50
32 140 16 16 16 16 16 78 2 100 4 M16 x 55
40 150 16 16 16 16 16 88 3 110 4 M16 x 55
50 165 18 16 18 18 18 102 3 125 4 M16 x 60
65 185 18 18 18 18 18 122 3 145 4 M16 x 60
80 200 20 18 20 20 20 138 3 160 8 M16 x 60
100 220 20 20 20 20 20 158 3 180 8 M16 x 65
125 250 22 20 22 22 22 188 3 210 8 M16 x 70
150 285 22 22 22 22 22 212 3 240 8 M20 x 70
200 340 24 24 - 24 24 268 3 295 12 M20 x 75
250 405 26 26 - 26 26 320 3 355 12 M24 x 90
300 460 28 28 - 28 28 378 4 410 12 M24 x 90
TROUBLE SHOOTINGHE
ALTH
& S
AFET
Y58
Simple to operate pumps
ALL CUSTOMERS MUST READ THIS NOTICE.
Health & Safety
• A suitably competent and experienced person must onlyoperate the Pump.
• Never work alone around open water.
• Wear suitable gloves when handling hoses and ancillaryequipment. Equipment can be contaminated with Leptospirosis,a disease carried by rats and spread in their urine.
• Use the lifting points provided and check before use that theattachment to the chassis and condition thereof is satisfactory.
• Site the pump on a dry level base clear of inflammable material.
• Before carrying out any maintenance ensure battery isolatorswitch is in off position and key is removed.
• Rotating machinery – Never insert anything into suction tubewhilst pump set is running.
• Check that all guards are secure and never operate the pumpwith missing or defective guards.
• Position the exhaust so that it is unlikely to cause a hazard tohealth and be aware of hot exhaust pipes.
• Before starting the engine the operator must familiarise himselfon how to stop it.
• Never use in a confined space – allow adequate ventilation forcooling and removal of engine exhaust fumes.
• Check that the pump and its performance is suitable for theapplication with regards to volume to be pumped, nature ofmaterial to be pumped and location of its destination.
• When checking coolant level care must be taken as the system ispressurised. Allow engine to cool before checking.
• When handling fuel, lubricating oil and battery electrolyte takenecessary precautions to protect skin and eyes.
• Always wear appropriate P.P.E. when working around openwater. Be aware of any trip hazards.
• Never block suction tube or hose with any body part to checkvacuum. Always use suitable blank fitting or check gauge.
• Only a competent person approved by Speedy Pumps Ltdshould carry out repairs.
• When handling fuel/lubricating oils, take precautions to avoidcontact with skin.
• Precautions must be taken to avoid injury to persons manualhandling suction and discharge hoses, WARNING – hosescontaining fluids may be extremely heavy.
DAILY CHECKS AND OPERATIONS
59TROUBLE SHOOTING
UK’s largest fleet of environmentally friendly pumps
Daily Checks
It is the hirers responsibility to carry out these checks
• Check engine oil level. Replenish using SAE 15/W40 orequivalent as necessary.
• Check fuel level. Replenish using clean: water free diesel.
• Check coolant level. Replenish using a 50/50 anti-freeze/watermixture as necessary.
• Check air filter. In dusty conditions clean primary filters regularly.
• Visually check drive belts – Do not remove guards.
• Check all meters and gauges are functional. Check for leaks.Check the engine oil pressure and temperature are withinacceptable limits.
• Check that the pump is not due to be serviced. See “NEXTSERVICE DUE” label. If pump is due to be serviced, or anydefects found, report to Speedy Pumps Ltd.
Operations
• Before starting the unit the operator must familiarise themselveson how to Stop the unit.
• Before starting the pump check fuel level, lubrication oil level,coolant level (do not remove the radiator cap when engine ishot). Replenish as necessary.
• Jack Legs should be set and positioned prior to pumping.
• If pump on wheeled undercarriage make sure hand brake isapplied when not connected to a vehicle.
• Ensure correct Strainer & Hose safety bond is fitted beforedropping hose in the water and before starting.
• Check security of all hoses.
• After starting pump set, check delivery hose for leaks and ensureany material being pumped is being discharged where intended.
• Check condition and security of hoses as leaks may cause banksto be undermined.
• Check the control panel readings. Indicate correctly within safeparameters. (Refer to operator manual for tolerances)
• Once the pump has started check for any abnormal noise orvibration. Stop unit immediately and report to Speedy Pumpsshould any be discovered.
• Do not lift the machine by any means, other than themanufacturers lifting eye or the fork lift pockets.
• To stop the pump: Keystart, Turn the key switch to the OFF position.
• Ensure jacklegs and jockey wheel are stowed correctly andhand brake is released prior to towing.
TROUBLE SHOOTINGFA
ULT
FIND
ING
60
Super-silent pumps
Fault Finding
• Engine does not crank – Check battery voltage. Check keyswitch operation. Check that no fault lamps are illuminated.
• The engine cranks but does not start – Check bothemergency stop buttons on the canopy exterior are released.
• Engine cranks but does not fire – Check fuel level. Checkemergency stop buttons are out.
• Engine stops due to high temperature – Check engine wasnot overloaded. Check radiator is not obstructed.
• Engine stops due to low oil pressure – Call Speedy PumpsLtd. Do not attempt to re-start the pump.
• Pump not pumping – Remove Suction Hose – Block offsuction tube with appropriate fitting. If vacuum gauge rises,pump is OK, check hoses.
• If gauge fails to rise:
a) Check outlet Non Return Valve is closed. (A draft from thedelivery fitting would indicate otherwise)
b) Valve OK – Check priming fluid level and top-up with cleanwater or antifreeze mixture.
c) Any other symptoms please contact Speedy Pumps Ltd.
• Black engine smoke/loss of power/speed – Check air filters areclean. Check fuel filters and fuel level. Check that the pump isnot being overloaded.
• Engine will not start after running out of fuel and refuelling –Fuel system requires bleeding.
THINGS TO DO / NOT TO DO
61TROUBLE SHOOTING
Newest fleet of pumps in the industry
Things NOT to do:
• Pump volatile or corrosive liquids
• Have inexperienced personnel operate pump
• Tamper with engine governor
• Operate pump with pump housing discharge outlet closed –pump and engine overheating will occur
• Operate pump with suction inlet obstructed – internal damagemay occur due to cavitation
• Use collapsible hose on suction side of pump
• Operate pump with suction hose buried in sand or mud,suspend strainer if possible
• Operate pump without a strainer
• Use a smaller than recommended suction hose
• Any increase in heat would require investigation to suction anddelivery lines
Things to do for efficient pumping:
• Locate pump as close as possible to liquid - keep suction lift toa minimum
• Check for proper hoses, reinforced on the suction side andflexible on the discharge side
• Have tight connection on suction side of pump with goodcoupling (s)
• Use strainer recommended by manufacturer
• Secure pump before operation
• Provide area for adequate ventilation of exhaust
• Pump liquids for which the pump was designed
• Check suction strainer regularly – keep clean
• Check and service pump and engine per maintenance schedule
• Drain pump before freezing weather
• Operate electric pumps at correct voltage, amperage and phase
• Be aware that if the pump is not priming (approx 2 minutes)there may be a leak somewhere in the suction side of thesystem or a vacuum pump, ie bearing broken. Refer to fault finding guide
DEPOT LOCATIONSDE
POT
LOCA
TION
S62
Emergency cover 24/7
WHERE TO FIND US
Satellite DepotsCornwall & DevonKent, Surrey & SussexNorth EastYorkshire
South Wales:Llanwern Milford HavenNewportPort Talbot
Speedy Pumps LtdBelfast Tel: 02890 742000Dublin Tel: 01 8301087London Tel: 01322 349861Midlands Tel: 0121 7728500 North West Tel: 01942 212222Scotland Tel: 0141 6472500South Wales Tel: 01639 821900South Coast Opening soon
For your nearest depot call: 0845 603 3363web: www.speedyhire.co.uk/pumpsemail: [email protected]
“The complete hire solution from your POWER division”
COMPRESSORS PUMPS GENERATORS
...Shhhhh
IS...
Newest fleet of pumps in the industry
SILENCE
HEAR YOURSELF THINK.All Speedy Pumps are super-silenced so ideal for residential or noise sensitive locations. Low noise emissions also help to reduce personal exposure andminimise risk.
Furthermore, by introducing new, cutting edge pump technology, our customers have already cut their fuel bills by up to 50% whilst seeing a dramaticincrease in pump efficiency. Included in the range are 3" – 12" road tow diesel, electric submersible and high head diesel pumps, available for immediate hirefrom our nationwide network of branches.
Simple design for guaranteed performance!To book a demonstration Lo-call:
0845 603 3363www.speedyhire.co.uk ...QUIETLY SUPERIOR
ENGINEERINGFENCING TRAININGACCESS LIGHTPLANT
SAFETY
PLUS
CUSTOMER SERVICES - UK 0845 601 5129/ROI 1850 812 [email protected]
www.speedyhire.co.uk www.speedyhire.ie
LIFTING – UK 0845 055 5155/ROI 01 830 1092An extensive range of hoisting, jacking, winching and material handling equipment,confined spaces and safety equipment for hire and sale.
SPACE – UK 0845 850 4404Portable site accommodation & storage, including self-contained toilet and canteenunits, vandal resistant, secure storage, jackleg and fire rated units.
TOOLSAccess equipment, drilling & breaking, woodworking, heating & lighting, pumping& plumbing, landscaping & cleaning equipment, pipework & engineeringequipment, plus all the essential consumable items.
SPEEDY NORTHERN – 01744 697000SPEEDY SCOTLAND – 01506 440000SPEEDY SOUTHERN – 01284 760842SPEEDY WESTERN – 0117 9555588SPEEDY IRELAND – 01 830 1101
SURVEY – UK 0845 602 1059/ROI 01 830 1094Hire and sales of levelling instruments, theodolites, lasers, inspection & detection,confined space and safety equipment plus a comprehensive repair service.
GENERATORS – UK 0845 605 5400/ROI 01 830 1087The industry’s largest and newest fleet of silenced generators plus fuelmanagement system and logistics and installation services.
Speedy Hire Plc is the most progressive tool and equipmenthire organisation:
• 4 acquisitions in 2006
• £263 million of equipment for hire
• £115 million of investment in products last year
• 3,500 helpful, informed and highly motivated staff
• Over 1,000 delivery vehicles
We pride ourselves on the strength of our customerrelationships; we are both a local supplier offering a quick,friendly service through any one of over 300 branches, and weare a supply chain partner offering national agreements andcustomised services.
WELDING
PUMPS – UK 0845 603 3363/ROI 01 830 1087An extensive range of cutting edge, environmentally friendly, fuel efficient and highperformance pumps.
COMPRESSORS – UK 0845 307 0777/ROI 01 830 1087State-of-the-art fleet of diesel, electric and 100% oil free air compressors, portableand stationary, plus full range of ancillaries and tower lights.