Exceptional Uniform Radiance for the Test and Calibration of Imaging and Non-imaging Devices
FEaTUREs●● ●Stepped●or● continuous● radiance● variability●from●5●to●2,800●cd/m2●● ●Spectraflect®● interior● provides●better● than●98%●radiance●uniformity●● ●Satellite●sphere●improves●uniform●input●into●main●sphere●● Interchangeable●components●● ●Radiometric●and●photometric●calibration●reports●● NIST●traceable●luminance●calibration●● Backed●by●an●ISO●9001:2000●Registered●● Quality●Management●System
aCCURaTESmall●Uniform●Source●Systems●feature●a●6●inch●diameter●integrating●sphere●with●a●highly●reflective●Spectraflect®●coated●interior●that●provides●better●than●98%●ra-diance●uniformity.●Both●durable●and●highly●stable●over●time,●this●material●ensures●the●consistent●integration●of●light●over●the●lifetime●of●your●sphere.The●USS●600●series●provides● luminance●output●with●a●manual● iris●diaphragm●from●15●to●2,800●cd/m2●or●continuous●output●variability● from●5●to●2,100●cd/m2●with●an●automated●variable●attenuator.●A●photopic●response●photodetector●moni-tors●the●source●luminance.●Each●system●provides●National●Institute●of●Standards●and●Technology●(NIST)●calibrations.
FlExIblE DEsIgN The●USS●600●yields●high●returns●on● investment●by●facilitating●system●modifica-tions,●upgrades●and●enhancements.●Swap●lamps●to●met●your●radiance●require-ment.●Add● filter●holder●and● filters● to● the●uniform●source● to●enhance●spectral●distribution.●Reduce●port●size●with●Spectraflect●coated●accessories●to●match●your●applications●field●of●view.
Easy-To-UsE The●durable●port●framed●exit●port●allows●for●repetitious●mounting●of●devices●un-der●test.●Portable●electronics●allow●quick●set-up●and●mobility●for●bench-top●use.●The●USS●600●is●operated●through●a●control●chassis●that●features●a●regulated●DC●constant●current●power●supply●and●an●SC●6000●System●Control.●Digital●readout●of●the●source●luminous●is●displayed●on●an●LCD●display●located●on●the●front●panel●of● the●SC●6000.●Both●IEEE-488●and●RS-232C●serial●ports●are● included●for●op-tional●computer●interface.
bEsT FoR CalIbRaTINg:●● Imaging●Radiometers●● Cameras●● Telespectroradiometers●● Small-Area●Remote●Sensing●Devices●● Displays
spECTRal RaDIaNCE ploT
Uss-600
small Uss Uniform source systemsCHAPTER●1●TEST-MEASUREMENT
http://www.onset-eo.com 1-51
Advanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s
Description and Model Uss 600s Uss 600C6●inch●Uniform●Source●System● AS-02451-201 AS-02451-301
system Includes6●inch●Uniform●Source●Sphere,●US-060-SF AS-02451-100 AS-02451-100Internal●Halogen●Lamp●Assembly*,●IHLS-100-035 AS-02631-035 AS-02631-035Preset●Power●Supply*,●LPS-100-0307 AS-02600-307 AS-02600-307Photopic●Detector,●SDA-050-P-RTA-CX AS-02522-401 AS-02522-401Radiometer/Photometer*,●SC●6000 AS-02702-100 AS-02702-100Iris●Diffuser●(S●Series●only) AS-02452-000 -Variable●Attenuator,●VA-100-SC●(C●Series●only) - AS-02450-100Motor●Controller*,●MC-1000●(C●Series●only) - AS-02609-000SCC-LU●Luminance●Calibration SCC-LU SCC-LU
system specifications Uss 600s Uss 600CSphere●Diameter● 6●in●(15●cm) 6●in●(15●cm)Exit●Port●Diameter 2●in●(5●cm) 2●in●(5●cm)Sphere●Coating●Reflectance 98% 98%Luminance●Range●(cd/m2) 15●–●2800 0-●2100Luminance●Range●(ft-L) 5●-●800 0-●600Illuminance●Range●(lux) 60●–●8700 0●–●6600Peak●Radiance:●(mW/cm2-sr-μm●at●0.9●μm) 8.0 6.0Luminance●Uniformity* >98% >98%Sphere●Dimension●(W●x●D●x●H) 9.83●x●10.0●x●11.7●in●(25●x●25●x●30●cm) 9.83●x●10.0●x●11.7●in●(25●x●25●x●30●cm)
Detector Vl Filter silicon photodiode Vl Filter silicon photodiodeActive●Area 5.7●mm2 5.7●mm2
Range Visible Visiblef1’ 4% 4%Connector BNC BNCRadiometer/photometer sC 6000 sC 6000Power●Requirements 110./220●VAC,●50/60●Hz 110./220●VAC,●50/60●HzCurrent●Dynamic●Range 1●pA●–●1●mA 1●pA●–●1●mAVoltage●Dynamic●Range 10●mVdc●–●50●Vdc- 10●mVdc●–●50●Vdc-Computer●Interface Ethernet Ethernet
power supplies lps-100-0307 lps-100-0307Power●Requirements 110./220●VAC,●50/60●Hz 110./220●VAC,●50/60●HzCurrent●Stability 3.07●A●+/-●0.1% 3.07●A●+/-●0.1%Current●Rise●Time 20●s 20●sWeight 6.5●lbs.●(2.9●kg.) 6.5●lbs.●(2.9●kg.)Dimension●(W●x●D●x●H) 8.3●x●10.5●x●3.5●in(21.1●x●26.7●x●8.9●cm) 8.3●x●10.5●x●3.5●in(21.1●x●26.7●x●8.9●cm)Compliance CE CE
lamp assemblies IHls-100-035 IHls-100-035Power Qty●1,●35●W Qty●1,●35●WColor●Temperature 3000K 3000K
Recommended Computer RequirementsOperating●System Windows●98®●2nd●Edition,●Windows●2000®●PE●or●laterDrives 3●1/2●in●Disk●Drive,●CD-ROM●Driveoptional accessories/CalibrationsLabsphere●Light●Source●Assemblies IHLS/EHLS●SeriesLabsphere●Power●Supplies LPS●SeriesSpectral●Radiance●Calibrations●(300-2400●nm) USC-SRRadiance●Calibration SCC-RAExit●Port●Luminance●Uniformity●Mapping USC-PMIlluminance●Calibration SCC-ILCustom●Spectral●Radiance●Calibrations OptionalRack●Mounted●Electronics Optional
spECIFICaTIoNs
sysTEM pRopERTIEs aND pERFoRMaNCE
*Product●sheet●available●for●additional●information
*●Applies●at●maximum●radiance,●uniformity●may●vary●at●lower●radiance●levels.
http://www.onset-eo.com1-52
CHAPTER●1●TEST-MEASUREMENTAdvanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s
Exceptional Uniform Radiance for the Test and Calibration of Imaging and Non-imaging Devices
FEaTUREs●● ●Continuous● radiance● variability● from●0● to● 9800,●13500,●or●24000●cd/m2●● ●Spectraflect● interior● provides●>98%● radiance●●uniformity●● Radiometric●and●photometric●calibration●reports●● NIST●traceable●luminance●calibration●● ●Backed●by●an● ISO●9000:2001●registered●quality●management●system
aCCURaTELabsphere’s●USS-800C●systems●feature●an●8● inch●diameter● integrating●sphere●with●a●2● inch●exit●port●suitable● for●portable● imaging●systems●and●arrays.●The●sphere●is●coated●with●highly●reflective●Spectraflect®●coated●interior●that●provides●a●better●than●98%●uniformity.●Both●durable●and●highly●stable●over●time,●Spectraf-lect●coating●ensures●the●consistent● integration●of● light●over● the● lifetime●of●your●sphere.The●USS-800C●systems●provide●continuous● luminance●output●variability● from●zero●to●9800,●13500,●or●24000●cd/m2,●depending●on●the●model.●A●built-in●phot-opic●response●photodetector●continuously●monitors●the●source●luminance.●Each●system●provides●National●Institute●of●Standards●and●Technology●(NIST)●traceable●calibration.
FlExIblE DEsIgN The●USS-800C●systems●yield●high●returns●on● investment●by●facilitating●system●modifications,●upgrades●and●enhancements.●A●broad●choice●of● light●sources●al-low●users●to●swap●lamps●in●order●to●choose●the●appropriate●configuration●to●meet●their● radiance●performance●requirement.●Spectraflect●coated●port●accessories●allow●users●to●reduce●the●port●size●of●their●sphere●to●match●their●applications.
Easy-To-UsE A●durable●port●framed●exit●port●allow●for●the●repetitious●mounting●of●devices●under●test.●The●USS-800●systems●are●operated●though●a●control●chassis●that●features●a●regulated●DC●constant●current●power●supply●and●an●SC●6000●radiometer/con-troller● that●provides●accurate●monitoring●and●control●of● the●exit●port● luminance.●Digital●readout●of● the●source●output● is●displayed●on●an●LCD●display● located●on●the●front●panel●of●the●SC●6000.●Ethernet●ports●are●included●for●optional●computer●interface.
bEsT FoR CalIbRaTINg:●● Imaging●Radiometers●● Cameras●● Telespectroradiometers●● Small-Area●Remote●Sensing●Devices●● Displays
TypICal RaDIaNCE
Uss-800C Continuous Uniform source system
Uss-800C
CHAPTER●1●TEST-MEASUREMENT
http://www.onset-eo.com 1-53
Advanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s
Model and Description Uss-800C-035R Uss-800C-075R Uss-800C-100RUSS-800C●8●inch●Continuous●Uniform●Source●System AS-02711-100 AS-02711-200 AS-02711-300
system Includes8●inch●Uniform●Source●Sphere,●USS-800-SF AS-02465-000 AS-02465-000 AS-02465-000External●Halogen●Lamp●Supply,●EHLS-100-35R,●75R,●100R AS-02630-035 AS-02630-075 AS-02630-100
Preset●Power●Supply,●LPS-100-0307,●0625,●0833 AS-02600-307 AS-02600-625 AS-02600-833Photopic●Detector,●SDA-050-P-RTA-CX AS-02522-301 AS-02522-301 AS-02522-301Variable●Attenuator,●VA-100-MIC AS-02455-000 AS-02455-000 AS-02455-000Radiometer/Photometer,●SC●6000 AS-02702-000 AS-02702-000 AS-02702-000Luminance●Calibration,●SCC-LU SCC-LU SCC-LU AS-02451-301
system specifications Uss-800C-035R Uss-800C-075R Uss-800C-100RSphere●Diameter 8●in●(20●cm) 8●in●(20●cm) 8●in●(20●cm)Exit●Port●Diameter 2●in●(5●cm) 2●in●(5●cm) 2●in●(5●cm)Sphere●Coating●Reflectance 98% 98% 98%Luminance●Range●(cd/m2) 0●-●9800 0●-●13500 0●-●24000Luminance●Range●(ft-L) 0●-●2800 0●-●4000 0●-●7200Illuminance●Range●(lux) 0●-●30000 0●-●42000 0●-●75000Peak●Radiance●(mW/cm2-sr-μm●at●0.9●μm) 24 52 69Luminance●Uniformity* >98% >98% >98%
lamp assemblies EHls-100-035R EHls-100-075R EHls-100-100RPower Qty●1,●35●W Qty●1,●75●W Qty●1,●100●WReflector Rhodium Rhodium RhodiumColor●Temperature 3000K 3000K 3000Kpower supplies lps-100-0307 lps-100-0625 lps-100-0833Power●Requirements 110./220●VAC,●50/60●Hz 110./220●VAC,●50/60●Hz 110./220●VAC,●50/60●HzCurrent●Stability 3.07●A●+/-●0.1% 6.25●A●+/-●0.1% 8.33●A●+/-●0.1%Current●Rise●Time 20●s 20●s 20●sWeight 6.5●lbs●(2.9●kg) 6.5●lbs●(2.9●kg) 6.5●lbs●(2.9●kg)
Dimension●(W●x●D●x●H) 8.3●x●10.5●x●3.5●in●(21.1x●26.7●x●8.9●cm)
8.3●x●10.5●x●3.5●in●(21.1x●26.7●x●8.9●cm)
8.3●x●10.5●x●3.5●in●(21.1x●26.7●x●8.9●cm)
Compliance CE CE CE
spECIFICaTIoNs
sysTEM pRopERTIEs aND pERFoRMaNCE
*●Applies●at●maximum●radiance,●uniformity●may●vary●at●lower●radiance●levels.
Custom●Spectral●Radiance●Calibrations●Optional
Detector Vl Filter silicon photodiodeActive●Area 5.7●mm2
Range Visiblef1’ 4%Connector BNCRadiometer/photometer sC 6000Power●Requirements 110./220●VAC,●50/60●HzCurrent●Dynamic●Range 1●pA●–●1●mAVoltage●Dynamic●Range 10●mVdc●–●50●Vdc-Computer●Interface Ethernet
Recommended Computer RequirementsOperating●System Windows●98®●2nd●Edition,●Windows●2000®●PE●or●laterDrives CD-ROM●DrivePorts TCP/IPoptional CalibrationsStandard●Spectral●Radiance●Calibrations USC-SR●(300-2400●nm)Radiance●Calibration SCC-RAExit●Port●Luminance●Uniformity●Mapping USC-PMIlluminance●Calibration SCC-IL
http://www.onset-eo.com1-54
CHAPTER●1●TEST-MEASUREMENTAdvanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s
Exceptional Uniform Radiance for the Testing and Calibration of Imaging and planer Detectors
FEaTUREs●● Stepped●or●Continuous●Radiance●Variability●● Better●than●98%●Radiance●Uniformity●● Spectraflect®●Interior●● Interchangeable●Components●● Calibration●Reports●● NIST●Traceable●Luminance●Calibration●● Control●Software●● ●Backed●by● ISO●9001:2000●Registered●Quality●Management●System
aCCURaTEThe●medium●Uniform●Source●Systems●are●designed●to●provide●exceptional●uni-form●spectral● radiance●for● the●test●and●calibration●of● imaging●and●non-imaging●detectors.●The●systems●provide●stepped●luminance●output,●or●continuous●output.●The●USS-1200●produces●zero●to●40,000●cd/m2●and●the●USS-2000●produces●zero●to●18,000●cd/m2.●Each●system●monitors●luminance●levels●in●both●cd/m2●and●foot-lamberts●and●all●calibrations●are●traceable●to●the●National●Institute●of●Standardsand●Technology●(NIST).Integrating●sphere●diameters●of●12●or●20● inches●are●coated●with●Spectraflect®●which●combines●a●98%●reflective●surface●with●nearly●perfect●Lambertian●proper-ties.●Highly●stable●over● time,● this●coating●ensures●the●consistent● integration●of●light●over●the●lifetime●of●your●sphere.
FlExIblE DEsIgN Four●ports●enable●the●system’s●radiance●levels●to●be●easily●modified●with●the●ad-dition●or●removal●of● light●sources.●The●system’s●exit●port●can●be●capped●when●not● in●use●or●reduced●in●size●with●optimal●Spectraflect●coated●accessories.●The●sphere●comes●with●an●extra●detector●port●for●expanded●radiance●monitoring.●The●electronics●rack●houses●the●system●controller,●power●supply●and●can●accommo-date●additional●motor●controllers,●power●supplies●or●a●detector●multiplexer.
Easy-To-UsE The●systems●ramp●to● full●power● in●20●seconds.●Matching● lamp●color● tempera-tures●ensure●color●shifts●are●eliminated●with●different●lamp●combinations.●Robust●port●frames●allow●for●easy,●repeatable●mounting●of●device●accessories.●The●sys-tems●offer●rack●mounted●electronics●for●quick●set-up●and●mobility● for●bench-top●use.
bEsT FoR CalIbRaTINg:●● Electronic●Imaging●Cameras●● Planar●Arrays●● Photometers●● Spectroradiometers●● Displays
spECTRal RaDIaNCE ploT
Medium Uss Uniform source systems
Uss-2000C
CHAPTER●1●TEST-MEASUREMENT
http://www.onset-eo.com 1-55
Advanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s
Description and Model Uss-1200 Uss-2000Stepped●Uniform●Source●System●(USS-S) AS-02448-201 AS-02444-201Continuous●Uniform●Source●System●(USS-C) AS-02448-301 AS-02444-301
system IncludesUniform●Source●Sphere,●US-120-SF●or●US-200-SF AS-02448-000 AS-02444-000Internal●Halogen●Lamp●Assemblies*,●IHLS-100-035 AS-02631-035 AS-02631-035Preset●Power●Supply*,●LPS-100-0307 AS-02600-307 AS-02600-307External●Halogen●Lamp●Assemblies*,●EHLS-100-100R AS-02630-100 AS-02630-100Preset●Power●Supplies*,●LPS-100-0833 AS-02600-833 AS-02600-833Photopic●Detector,●SDA-050-P-RTA-CX AS-02522-401 AS-02522-401Variable●Attenuator●(C●Series),●VA-100-SC AS-02450-100 AS-02450-100Motor●Controller*●(C●Series),●MC-1000 AS-02702-000 AS-02702-000Radiometer/Photometer*,●SC●6000 AS-01636-100 AS-01636-100Luminance●Calibration SCC-LU SCC-LU
Technical specification Differences Uss-1200s Uss-1200C Uss-2000s Uss-2000CLuminance●Range●(x1,000●cd/m2) 10,●20,●30,●40 0●-●40 4.6,●9.2,●13.8,●18 0●-●18Peak●Radiance●(mW/cm2-sr-μm●at●0.9●μm) 98.5 98.5 55 55Color●Temperature 3000K 3000K 3000K 3000K
system Configuration Uss-1200s Uss-1200C Uss-2000s Uss-2000CSphere●Diameter 12●in●(30●cm) 12●in●(30●cm) 20●in●(50●cm) 20●in●(50●cm)Exit●Port 4●in●(10●cm) 4●in●(10●cm) 8●in●(20●cm) 8●in●(20●cm)
Lamp●Assembly*●Power Qty●4,●35●W Qty●3,●35●WQty●1,●100●W Qty●4,●35●W Qty●3,●35●W
Qty●1,●100●W
Power●Supplies Qty●4,●for●35●W●lampsQty●3,●for●35●W●lampsQty●1,●for●100●W●lamp
Qty●4,●for●35●W●lampsQty●3,●for●35●W●lampsQty●1,●for●100●W●lamp
Current●Stability 3.07●A●+/-●0.1% 3.07●A●+/-●0.1%8.33●A●+/-●0.1% 3.07●A●+/-●0.1% 3.07●A●+/-●0.1%
8.33●A●+/-●0.1%
Sphere●Dimension●(W●x●D●x●H)17.1●x●11.3●x●19.7●in
(43.4●x●28.7●x●50.0●cm)
17.1●x●11.3●x●19.7●in
(43.4●x●28.7●x●50.0●cm)24●x●18.5●x●23.8●in(61●x●47●x●60●cm)
24●x●18.5●x●23.8●in(61●x●47●x●60●cm)
Rack●Dimension●(W●x●D●x●H)19.7●x●21.7●x●21.9●in(50●x●55●x●56●cm)
19.7●x●21.7●x●21.9●in(50●x●55●x●56●cm)
19.7●x●21.7●x●21.9●in(50●x●55●x●56●cm)
19.7●x●21.7●x●21.9●in(50●x●55●x●56●cm)
Detector Vl Filter silicon photodiodeActive●Area 5.7●mm2
Range Visiblef1’ 4%Connector BNC
For all systemsIntegrating●Sphere Uniform●Source●Integrating●SphereSphere●Coating Spectraflect®
Sphere●Coating●Reflectance 98%Luminance●Uniformity* >98%
Radiometer/photometer sC 6000Power●Requirements 110./220●VAC,●50/60●HzCurrent●Dynamic●Range 1●pA●–●1●mAVoltage●Dynamic●Range 10●mVdc●–●50●Vdc-Computer●Interface Ethernetlamp power supply lps-100Power●Requirements 110./220●VAC,●50/60●HzCurrent●Rise●Time 20●s 20●sCompliance CE CE
Recommended Computer RequirementsOperating●System Windows●98®●2nd●Edition,●Windows●2000®●PE●or●laterDrives 3●1/2●in●Disk●Drive,●CD-ROM●Drive
optional accessories/CalibrationsInternal●&●External●Light●Source●Assemblies IHLS●(internal)/EHLS●(external)Power●Supplies LPSSpectral●Radiance●Calibration USC-SR●(300-2400●nm)Radiance●Calibration SCC-RAExit●Port●Luminance●Uniformity●Mapping USC-PMIlluminance●Calibration SCC-ILCustom●Spectral●Radiance●Calibrations Optional
spECIFICaTIoNs
sysTEM pRopERTIEs aND pERFoRMaNCE
*Product●sheet●available●for●additional●information
http://www.onset-eo.com1-56
CHAPTER●1●TEST-MEASUREMENTAdvanced●Integrating●Sphere●S
ystemGoniophotom
eterIntegrating●S
phere●System
rLE
D●Spatial●
Analyzer
Application●S
phere●Devices
UVA●/●U
VB●Tester
Calibration●&
●Solar●
Source
Reflectance●Standards
Pow
er●Meter
PSD●System
Laser●Alignm
ent●System
Polarim
eterFiber●O
ptic●●Spectrom
eterMaterial●
Analyzer
Spectral●●
Products
Beam
●●Diagnostic
Wave●Front●●Sensor
Optics●Q
uality●Diagnostics
Auto●Focusing●System
s