12
Carmichaels, Pennsylvania Manufactured by Operator’s Manual Heat Transfer Equipment STX CLAM

Sprint Clam User Manual

Embed Size (px)

DESCRIPTION

Stalls User Manual.

Citation preview

Page 1: Sprint Clam User Manual

Carmichaels, Pennsylvania

Manufactured by

Operator’s Manual

Heat Transfer Equipment

STX CLAM

Page 2: Sprint Clam User Manual

TABLE OF CONTENTS

STX CLAM PARTS LOCATION GUIDE..............................................................

STX CLAM CONTROL PANEL...........................................................................

OPERATING INSTRUCTIONS..........................................................................

STX CLAM ELECTRICAL SCHEMATIC............................................................

3

4

5

6-11

12

Page 2

IMPORTANT SAFETY INSTRUCTIONS............................................................

Page 3: Sprint Clam User Manual

Important Safety Instructions

Page 3

WHEN USING YOUR APPLIANCE, BASIC PRE-CAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

1. Read all instructions.

2. Use appliance only for its intended use.

3. To reduce the risk of electric shock, do not immerse the appliance in water or other liquids.

4. Never pull cord to disconnect from outlet, instead grasp plug and pull to disconnect.

5. Do not allow cord to touch hot surfaces, let appliance cool completely before putting away.

6. Do not operate appliance with a damaged cord, or if the appliance has been dropped or damaged. To reduce the risk of electric shock, do not disassemble or attempt to repair the appliance, take it to a qualified service person for examination and repair. Incorrect reassembly or repair could cause a risk of fire, electric shock, or injury to persons when the appliance is used.

7. Close supervision is necessary for any appliance being used by or near children. Do not leave appliance unattended while connected.

8. Burns could occur from touching hot metal parts.

9. To reduce the likelihood of circuit overload, do not operate another high voltage appliance on the same circuit.

10. If an extension cord is absolutely necessary, a 20 ampere rated cord should be used. Cords rated for less amperage may overheat, care should be taken to arrange the cord so that the cord cannot be pulled or tripped over.

SAVE THESE INSTRUCTIONS

Page 4: Sprint Clam User Manual

Page 4

PARTS LOCATION GUIDE

FRONT VIEW

SIDE VIEW

ST X CLAM PRESS

Lift Handle

LED Display

12 V Magnet (on optional auto release only)

Power On/Off Switch

PressureAdjustment Knob

Circuit Breaker

Power Cord

* Featured on the opposite side of the press

Page 5: Sprint Clam User Manual

Page 5

TIME

MODE

SE T

TE MP

CONTROL PANELSTX CLAM PRESS

Digital Display

Temp Indicator

Set Indicator

Time Indicator

Pressure Indicator

“Increase” Button

“Mode” Button

“Decrease” Button

Page 6: Sprint Clam User Manual

Page 6

Operating Instructions

STX CLAM PRESS

The STX CLAM PRESS Operating Instructions are designed with you in mind. Carefully read and follow the step-by-step instructions for best results. If you experience any difficulty, carefully re-read the instructions and try again.

CONNECT THE POWER CORD:

Connect the power cord into a properly grounded electrical outlet with a sufficient amperage rating.

120 Volt

240 Volt

Extension Cords, if used, should be as short as possible and not less than 12 gauge. Heavy duty cords are recommended.

Circuits that have under 15 amps or other high demand equipment or appliances (especially more than one heat seal machine) should notbe used.

NOTE:If the supply cord is damaged, it must be replaced by the manufactureror its service agent or a similarly qualified person in order to avoid hazard.Use HSJ type, rated 250 V - 10 AMP for replacement.

Your STX CLAM PRESS requires a full 15 amp grounded circuit for 120 volt operation.

Your STX CLAM PRESS requires a full 7.5 amp grounded circuit for 240 volt operation.

Step 1

Pay particular attention to the risk of burns which can be sustained by touching the heatedplaten during use.

Keep hands clear from the platens of the press during platen lock down as the pressurecan cause injury.

Press should be placed on a sturdy suitable stand at least 36”L x 24”W x 29”H.

Work area must be kept clean, tidy and free of obstructions to the movements of the heat press.

Power supply cord must be disconnected before cleaning or servicing press.

Page 7: Sprint Clam User Manual

Page 7

Step 2

SWITCH THE SYSTEM ON

Locate the lif t handle and position the heat platen in the up (load) position.R

Locate the Power ON/OFF Switch on the press.

Turn the Power Switch on.

ON

OFF

POWER ON/OFF SWITCH

CAUTION

FAILURE TO FOLLOW THESE INSTRUCTIONS WILL CAUSE:

1. Erratic controller functions.2. Inaccurate displays and slow heat-up.3. The circuit breaker to disengage.

B. Manual Release Unit

Remove from carton

Locate the packaging bolt positioned on top-center of press.

Packaging bolt must be removed prior to turning press on or operating press.

A. Auto Release Unit

Locate the Power ON/OFF Switch on press.

Turn the Power Switch on.

Page 8: Sprint Clam User Manual

Step 3 ADJUST THE TEMPERATURE

Page 8

Press the Mode Select Button located in the center of the Control Panel.The (SET) and (TEMP) Lights located next to the display willilluminate indicating you are in the Adjust Temperature Mode.

Next, press the (-) Button located to the left of the Mode Select Button to lower the temperature setting, or press the (+) Button located to the rightof the Mode Select Button to raise the temperature setting. The temperature can

0 0 0 0be set from 205 F (96 C) to 430 F (221 C).

The LED will display your changes as you make them.

0 0NOTE: The temperature indicator will only display temperatures 205 F (96 C) and up.

Locate the LED Display on the Press.

TI ME

MODE

SE T

TE MP

Digital Display

Temp Indicator

Set Indicator

Time IndicatorPressure Indicator

“Increase” Button

“Mode” Button

“Decrease” Button

Page 9: Sprint Clam User Manual

Step 4

Page 9

ADJUST THE TIME

Once you have completed adjusting the temperature press the Mode SelectButton again. This will advance you to the Adjust Time Mode. The (SET)and (TIME) Lights will illuminate, indicating you are in the Adjust TimeMode. Adjust the time in the same manner that you adjusted temperature. Thetime can be set from 001 to 999 seconds.

To exit the Adjust Temperature and Time Modes press the Mode Select Button athird time. All lights will be off and the press will return to the Print Mode.

IMPORTANT: The press will not function when the (SET) Light isilluminated. This light indicates that you are in the AdjustTemperature or Time Mode not the Print Mode.

REMEMBER:

PRESS the MODE SELECT button ONCE to advance to the ADJUSTTEMPERATURE MODE.

PRESS the MODE SELECT button AGAIN (Second Time) to advance to theADJUST TIME MODE.

PRESS the DECREASE and INCREASE buttons to make the changes desired.

Page 10: Sprint Clam User Manual

Page 10

S tep 5

The Pressure Adjustment Knob is located in the center of the heat platen.

Adjust the pressure by turning the knob clockwise to increase pressure andcounter clockwise to decrease pressure.

REMEMBER:

ADJUST THE PRESSURE

To allow for the thickness of your garment whenadjusting the pressure.

WARNING: STRUCTURAL DAMAGE CAUSED BY EXCESSIVEPRESSURE IS NOT COVERED UNDER THELIMITED WARRANTY!

PressureAdjustment Knob

PressureReadout

PRESSURE REATOUT (IF EQUIPPED)

A visual Pressure Readout is located on the lower right side of the LED Display.When the handle is locked into the Print Position a pressure number will be displayed.Readout will be on a scale of 0 - 9. 0 Pressure would indicate no Pressure at all and 9 would indicate very heavy Pressure.

To adjust the Pressure simply turn the Pressure Adjustment Knob to the right or clockwiseto increase the Pressure and to the left or counter clockwise to decrease the Pressure.The readout will display the Pressure when locked down in the print position.

1 - 3 = Light Pressure4 - 7 = Medium Pressure8 - 9 = Heavy Pressure

TI ME

MODE

SE T

TE MP

Page 11: Sprint Clam User Manual

Page 11

S tep 6Once your equipment has reached the designated temperature, position thegarment and application and proceed to press.

Lower and lock the heat platen into the press position. This procedure will startthe automatic timing process.

A. Auto Release UnitThe timer will

B. Manual Release UnitThe timer will automatically count down and audibly signal you to lift the heatplaten into the “UP” position whe n the press cycle is complete.

The time will automatically re-set and you are ready to continue with the nextapplication.

automatically count down and audibly signal you to lift the heatplaten into the “UP” position when the press cycle is complete. Please be aware af ter time is complete gas shocks will automatically release the platen into the “up” position.

PRINT

0 0200 F (93 C)0 0205 F (96 C)0 0430 F (221 C)

= The lowest temperature the unit will display= The lowest set temperature possible= The highest set temperature possible and the highest temperature the unit will display .

Page 12: Sprint Clam User Manual

ELECTRICAL SCHEMATIC

Page 12

IMPORTANT: MAKE SURE CORRECT VOLTAGECONNECTION IS USED TO THE CONTROLLER

CIRCUIT BREAKER

CIRCUIT BREAKER

POWER CORD

(240V)

1750 WATT HEATER

RTD

1750 WATT HEATER

GREEN

US 240V VERSION

BLACK

CB WHITE

CB

SW2

PROXIMITY

(120V)

TO POS.#4

TO POS.#2

BLACK

WHITE

SW1

HEATER

RTD

GND

4

5

3

TERMINAL STRIP

1

2

HEATER

10 AMP

10 AMP

SWITCH

US 120V VERSION

ON-OFFSWITCH

PROXIMITYSWITCH

SWITCHON-OFF

GERMAN 240V VERSION

CIRCUIT BREAKER10 AMP CB

SW1

1750 WATT HEATER

(240V)

RTD

HEATER

GNDHEATER

IMPORTANT: MAKE SURE CORRECT VOLTAGECONNECTION IS USED TO THE CONTROLLER

SW2

N

IECINLET

L

14 GA.

GREEN

BLACK

WHITE

22

55

4

3

4

3

TERMINALBLOCK

1 1

BLACK 14 GA

WHITE 14 GA

TRIAC

BLACK 22 GA

WHITE 22 GA

WHITE 22 GA

WHITE 14 GA

BLACK 14 GA

BLACK 22 GA

TRIAC

NEUTEARTH 120V

240V

MT2G

CONTROLLER

EARTH

CALIBRATION POTTEMPERATURE

CONTROLLER

120VNEUT 240V

G MT2

TEMPERATURECALIBRATION POT

STX CLAM PRESS

SWITCHON-OFF

CIRCUIT BREAKER10 AMP CB

SW1

N

IECINLET

L

14 GA.

GREEN

BLACK

WHITE

II 12V output

II 12V output

JUMPER 2 PLACES