9
SPS 200 MHz RF Upgrade Eric Montesinos LIU-SPS coordination meeting 06 June 2013

SPS 200 MHz RF Upgrade

  • Upload
    harsha

  • View
    29

  • Download
    0

Embed Size (px)

DESCRIPTION

SPS 200 MHz RF Upgrade. Eric Montesinos LIU-SPS coordination meeting 06 June 2013. Intervenants. New BAF3 RF building. Building BAF3 Integration studies completed Enquiry ‘Etude Genie Civil’ sent out Final comments today Construction starts Fall 2013 Building ready mid-2015 all inclusive. - PowerPoint PPT Presentation

Citation preview

Page 1: SPS 200 MHz RF Upgrade

SPS 200 MHz RF Upgrade

Eric Montesinos

LIU-SPS coordination meeting 06 June 2013

Page 2: SPS 200 MHz RF Upgrade

Intervenants

15 August 2012 2LIU SPS RF

Dep-Group Persons

BE-RF Eric Montesinos, Charles Julie, SPS power team, Thomas Bohl, Wolfgang Höfle, Urs Wehrle, Elena Shaposhnikova, Philippe Baudrenghien

BE-ABP Ghislain Roy (BE space manager), Patrick Bestmann, Yannis PapaphilippouBE-ASR Emmanuel PaulatBE-BI Christian Boccard, Patrick OdierDGS-SEE Guillaume Fontana, Cécile PintoEN-CV Mauro Nonis, Glen MasonEN-EL Guillaume Gros, Joël Lahaye, Christophe CrombezEN-HE Caterina Bertone, Pascal Brunero, Serge Pelletier, Yann SeraphinEN-MEF Frédéric Galleazzi, Yvon Muttoni, David McFarlane, Antoine KosmickiGS-SE Luz-Anastasia Lopez-HernandezTE-VSC Paolo Chiggiato, Antonio MongelluzzoTE-MSC Jérémie Bauche

Page 3: SPS 200 MHz RF Upgrade

3LIU SPS RF

New BAF3 RF building

Building BAF3 Integration studies completed Enquiry ‘Etude Genie Civil’ sent out Final comments today• Construction starts Fall 2013• Building ready mid-2015 all inclusive

15 August 2012

Page 4: SPS 200 MHz RF Upgrade

Amplifiers

Drivers (SSA): MS completed : 17 companies selected TS written to be sent out soon (pending YL1530

decisions)• FC December 2013

Finals (SSA or Tetrodes): MS completed : 7 companies selected TS written Will be sent out once Driver will be

adjudicated• FC December 2013

Combiners (3 dB above 100 kW)• After Finals have been selected

Transmission lines (coaxial, 345 mm outer)• Same as Combiner

15 August 2012 4LIU SPS RF

Drivers16 SSA

Final16 PAs

3 dBcombinersand power loads

120 m and 180 mCoaxial lines

To cavity input 120 m away

From Beam Control

1/16 splitter

Page 5: SPS 200 MHz RF Upgrade

May 2013 Amplifiers Schedule

23 May 2012 5LIU SPS RF

2013 2014 2015 2016 2017 2018

JulyIT sent

DecemberFC Order placed IT : Invitation to Tenders

FC : CERN Finance CommitteeFAT : Factory Acceptance TestsCERN AT : CERN Acceptance TestsLD Tests : Long duration tests

: Long Technical Stop, No beams

MarchFirst Series FAT

MarchPre-series FAT

OctoberCERN approval for Series Production

(after LD tests)May

Pre-seriesCERN AT

DecemberLast SeriesCERN AT

JunuaryIT sent

JuneFC Order placed

DecemberFirst Series FAT

MarchCERN AT

SeptemberMayCERN approval for Series Production

(after LD tests)

DecemberPre-series FAT

DecemberLast SeriesCERN AT

Drivers

Finals

Page 6: SPS 200 MHz RF Upgrade

LSS3 rearrangement LS1

15 August 2012 6LIU SPS RF

HBW kicker

BPWA:319 to 31101

AEWB:319 To 31510

• HBW Damper will be prepared• BPWA and AEWB new locations have

been validated• ECR validated

Schedule : Summer 2013

Page 7: SPS 200 MHz RF Upgrade

June 2013 Schedule

15 August 2012 7LIU SPS RF

2011 2012 2013 2015 2016 2017 20192014

Studies

Tendering

Construction

Installation

CommissioningStart up

2018

Studies

HBW (kicker and Pickup)

New power couplers

Cavities pickups vacuumCV, EL

Studies

Authorizations

Construction

Services (CV, EL) Startup

Spare sections

LLRF Design and proto

LLRF TestsLLRF Series

New RF Building

LSS3 Tunnel Integration

New RF Power Amplifiers and LLRF

6 months cavities re-arrangement2 months RF Power conditioning

4 months LLRF commissioning

Coaxial Lines

Page 8: SPS 200 MHz RF Upgrade

8LIU SPS RF

Spending profile

23 May 2012

Item 2012 2013LS1 2014 2015 2016 2017 2018

LS2 Total

Building Civil Engineering(Natacha)

Basement 4000 CHF/m2

First floor 2000 CHF/m2 450 150 3’100 800 4’500Building Ventilation(Mauro) 350 100 850 1’000Electrical Network High Power(Joel)

Study, documentations, HV transformers, cabling, accessories 100 200 500 800

First RF Power Amplifier(all inclusive)

1100 kW x 7.5 CHF/W(based on 800 MHz 2010 prices) 350 5’450 3’500 200 9’500

Second RF Power Amplifier 1100 kW x 7.5 CHF/W 1’500 4’000 1’500 7’000Coaxial lines 2 x 25 x 6 m x 6500 CHF/6m 200 300 500Cavities modifications 4 x 150 kCHF + 2 x 100 kCHF 400 400 800Main power Couplers 10 x 100 kCHF 200 300 300 200 1’000Beam Control 2 x 700 kCHF 100 400 600 300 1’400

Total 450 500 3‘950 8’000 7’000 5’400 1’500 26’500

2012 2013 2014 2015 2016 2017 20180

50001000015000

kCHF

Red : initial profileBlue : New profile

Page 9: SPS 200 MHz RF Upgrade

THANK YOU FOR YOUR ATTENTION!