SPS MD run w17: e-cloud monitors and pressure rise
Coating news
By M.T.
m.taborelli 2010/05/20
q
51340 51480 51540
P 51824
StSt StSt
MBB dipoles
ECM
uncoated uncoated new a-C coated
m.taborelli 2010/05/20
1.00E-09
1.00E-08
1.00E-07
1.00E-06
1.00E-05
23:10:00 23:22:00 23:34:00 23:46:00 23:58:00
VGHB_51340
VGHB_51480
VGHB_51540
VGHB_51824
1x72 bunches 450 GeV
less than 5E-9
Static pressure and start of MD, unstable beam, large losses
Highest pressure in freshly inserted ECM StSt
Highest pressure in freshly inserted uncoated dipole
lowest pressure in old conditioned uncoated inserted dipole27.04
P[m
bar
]
-Static pressure as usual (for instance w25/09 or w45/09)
q
51340 51480 51540
m.taborelli 2010/05/20
1.0E-08
1.0E-07
1.0E-06
1.0E-05
00:00:00 00:30:00 01:00:00 01:30:00 02:00:00 02:30:00 03:00:00
p [m
bar]
uncoated refcoateduncoated newECMdrift space after ECM
nominal int. 4x72 bunches accelerated
Second night of MD, stable beam, very low losses
29.04.101.0E-08
1.0E-07
1.0E-06
1.0E-05
29.04.2010 01:26:24
p [m
bar]
uncoated refcoateduncoated newECMdrift space after ECM
nominal int. 4x72 bunches accelerated
-Conditioning is very weak-Difference in dynamic pressure due to history more than coating-large pressure rise in ECM (as before)
m.taborelli 2010/05/20
StSt.
-Almost no conditioning of StSt; one monitor with 2 times more signal than the other-Decrease in current in carbon monitors …due to (weak) pressure decrease?
Uni
t: in
tegr
ated
ele
ctro
n cu
rren
t ove
r sup
ercy
cle
(nC)
inte
grat
ed F
BCT
over
sup
ercy
cle
(1e1
0pro
tons
/bun
ch) E-cloud monitors
a-CNe13a-CZr
x104
m.taborelli 2010/05/20
Pressure rise comparison: data of MD w25/09
1.00E-08
1.00E-07
1.00E-06
12:00:00 00:00:00 12:00:00 00:00:00 12:00:00 00:00:00
time
pre
ssu
re m
axx
51480
51540
51340
15/6 16/6
48 bunches 2 - 3 batchesno accel
72 bunchesno accel1 batch
change of tune
72 bunchesno accel2 batches
17/6
72 bunchesno accel3 batches
72 bunches with acceleration
3 batches
4 batches
2010 w17 2009 w25
4b3b
- No significant differences except for the higher pressure in the recently inserted dipole51480
m.taborelli 2010/05/20
Fast pressure acquisition (300Hz)
4 batches with acceleration
P[m
bar]
Synchronization with FBCT clearly shows the effect of each batchThe minimum of pressure is at second injection
The differences in individual shapes are not understood
Inte
nsity
10
10p
/b
m.taborelli 2010/05/20
Comparison fast and normal (PVSS, 1s) acquisition
Synchronization accuracy 1s due to PVSS (1s resolution)
Still some calibration to be corrected on data of 51480
m.taborelli 2010/05/20
Next liners after w22
StSt grooves insert, (M.Pivi)Inserts just arrived at CERN
Partial a-C coating to verify the effect of e-cloud close to a-C: -non uniform in lateral direction to profit of resolution of strip detector
2 half shells
m.taborelli 2010/05/20
Coatings
-half-length chamber with MBB profile coated (SEM for thickness profile in progress): more uniform with rectangular cathodes than cylindrical excepted for the gap between rods (see figure).
-7m prototype next week; then 7 m real MBB chamber (with rectangular cathodes)
-Coated 2 liners for ECM in the SPS: SEY=0.95 after one week air exposure! (high power => high deposition rate and high resulting substrate temperature ~250C)
-Coated tube for ion induced desorption experiment in Linac 3 (running)
-Characterization: pumpdown measurements done on CNe53 (round tube) confirm 10x higher outgassing of a-C wrto unbaked StSt
-Asked two firms for a sample with alumina plasma spray to test first degassing and dielectric strength
m.taborelli 2010/05/20
Coating with rectangular cathodes
Defects of the substrate
“plasma rings” at extremities
Defects due to a gap in the cathode(new cathode design tested today)
m.taborelli 2010/05/20
Next on SPS :-w22: replace the ECM and intermediate section with a-C coated ECM and measure again the dynamic pressure simultaneously with e-cloud
-w22: remove dosimeters (measurements of dose to identify possible location of RGA electronics to identify desorbed gases)
-w26: extract removable sample for SEY analysis (to verify the effect of e-bombardment on the a-C coating)
-w30: insertion of coated MBB (3 m prototype OK, tubes ready for end of May probably with rectangular cathodes)
-w26 or w30: replacement of a-CZr ECM with half-coated ECM
-at the next venting of dipoles we could isolate a pumping port (pressure gauge+ion pump) through a manual valve from the main vacuum system of the machine to verify the behavior with beam and magnet ramp
m.taborelli 2010/05/20
m.taborelli 2010/05/20
1.00E-08
1.00E-07
1.00E-06
1.00E-0500:02:53 00:03:14 00:03:36 00:03:58 00:04:19 00:04:41 00:05:02 00:05:24 00:05:46 00:06:07 00:06:29 00:06:50 00:07:12 00:07:34 00:07:55 00:08:17 00:08:38
VGHB_51340
VGHB_51480
VGHB_51540
VGHB_51824
VGHB_51877
Effect of the magnets on the gauge signals