SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
11MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
The Magellan Stand Alone Power System combines renewable energy sources and batteries together with a generator to provide remote farms or communities with safe, clean, reliable, sustainable and cost-effective electrical power that is not affected by natural disasters such as fire and flood.
The Magellan SPS is designed to operate independently of the grid and maximise the use of renewable energy.
Using high-efficiency Lithium batteries, smart microgrid and high-reliability power electronics, the Magellan Stand Alone Power Systems are maintenance free, intelligent and designed to supply high-quality, stable power to remote communities.
FEATURES:
Rugged Industrial Design 25 Year Service Life Smart Microgrid Minimising Generator Run Time Stores Solar & Generator Power Compliant with AS4509 High Efficiency Lithium Batteries Pure Sinewave Inverter Output Bumpless Power Transfer from Solar/
Battery/ Generator Optional Remote Monitoring Air-conditioned Battery Enclosure
12 MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
COMPONENTS OF STAND ALONE POWERTHESE INCLUDE:
PV Panels A Magellan Inverter/ Charger Lithium Batteries Diesel Generator
All components of the Magellan Stand Alone Power System are chosen for their durability and reliability in harsh conditions.
Operational diagram (left) showing the system and the way it is connected to a house or community.
13MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
EXAMPLE APPLICATIONS:
Regional Communities
Farms
Rural Homes
Mining Camps
Magellan Power’s Microgrid Controller (left)
14 MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
INVERTER SYSTEM SPECIFICATION
Rated Power 5-10kVA / 1 PHASE
Configuration Bidirectional Conversion
Housing To suit equipment rating and application
AC Output
Voltage Nominal 230/240VAC
AC Grid Voltage Range 207V - 264V
AC Grid Frequency Range 45Hz - 55Hz
Voltage Regulation ±1%
Frequency 50 ± 0.1Hz
Waveform Sinusoidal
THD Less than 5%
Power Factor 0.9 lag to 0.9 lead
Phase Single
Standards As per AS 62040, AS3100, AS4509
AC Current THD Less than 5% as per AS 4777
Communication Interface Modbus RTU (RS232/RS485), USB, Modbus TCP (Ethernet)Distributed Network Protocol 3 (Ethernet) Inbuilt website (Ethernet)
Ambient Temperature 0° to 50°C
MonitoredSystemParameters
Battery State-of-Charge, Current, Cell Voltage & Temperature, Inverter Voltage, Current, Watts, VARs & Temperature Mains Voltage, Current, Watts, VAR, Power Factor & Frequency
In-builtDiagnosticSystem
Periodic Data Logging into Non-Volatile Memory. (200 days of logged data at 15 minute intervals) (2 years of logged data at 1 hour interval) Battery SOC, Voltage, Current, Power & Temperature, Mains Voltage, Power & VARs, Power Factor Inverter Voltage, Temperature, Power & VARs Min & Max Cell Voltage, Fault Event Recorder.
Cooling (Inverter) Forced air with temperature controlled cooling fans
Maximum Humidity 95% R.H., Non Condensing
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
15MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
BATTERY SYSTEM SPECIFICATION
DESCRIPTION VALUE NOTES
Rated Capacity 25kWh -
Module Capacity 3.2kWh/6.5kWh -
Minimum Voltage 42V -
Nominal Voltage 48V -
Maximum Voltage 58.8 -
Max Continuous Charge Current
0.5C -
Duty Cycle 1 cycle per day -
Round Trip Efficiency >95% @ 23 ±3°C as a new product
Cell Cycle Life >4000 @ 23 ±3°C, 1C/1C, 80% DoD
Operational Temperature Optimal - 15°C to 50°C
Storage - - 15°C to 60°C
MAGELLAN BATTERY MODULE
DESCRIPTION VALUE NOTES
Rated Capacity 17-50kWh -
Cell Capacity To suit equipment rating -
Minimum Voltage 240V -
Nominal Voltage 256V -
Maximum Voltage 320V -
Max Continuous Charge Current
0.5C -
Duty Cycle 1 cycle per day -
Round Trip Efficiency >95% @ 23 ±3°C as a new product
Cell Cycle Life >4000 @ 23 ±3°C, 1C/1C, 80% DoD
Operational Temperature Optimal - 15°C to 50°C
Storage - - 15°C to 60°C
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
16 MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
THREE PHASE INVERTER SYSTEM SPECIFICATION
Rated Power 30kVA - 100kVA / 3 PHASE
Configuration Bidirectional Conversion
Housing To suit equipment rating and application
AC Output
Voltage Nominal 400V/415V
AC Grid Voltage Range 358V - 438V
AC Grid Frequency Range 45Hz - 55Hz
Voltage Regulation ±1%
Frequency 50 ±0.1Hz
Waveform Sinusoidal
THD Less than 5%
Power Factor 0.9 lag to 0.9 lead
Phase Three-phase, four wire
Grid Support Supports grid by providing reactive and active power compensation
Standards As per AS 62040, AS3100, AS4509
Maximum Phase Imbalance 100%
AC Current THD Less than 5% as per AS 4777
Communication Interface Modbus RTU (RS232/RS485), USB, Modbus TCP (Ethernet)Distributed Network Protocol 3 (Ethernet) Inbuilt website (Ethernet)
Ambient Temperature 0° to 50°C
MonitoredSystemParameters
Battery State-of-Charge, Current, Cell Voltage & Temperature, Inverter Voltage, Current, Watts, VARs & Temperature Mains Voltage, Current, Watts, VAR, Power Factor & Frequency
In-builtDiagnosticSystem
Periodic Data Logging into Non-Volatile Memory (200 days of logged data at 15 minute intervals) (2 years of logged data at 1 hour interval). Battery SOC, Voltage, Current, Power & Temperature, Mains Voltage, Power & VARs, Power Factor Inverter Voltage, Temperature, Power & VARs Min & Max Cell Voltage, Fault Event Recorder.
Cooling Inverter Forced air with temperature controlled cooling fans
Maximum Humidity 95% R.H., Non Condensing
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
17MAGELLAN POWER ENERGY STORAGE | magellanpower.com.au
THREE PHASE BATTERY SYSTEM SPECIFICATION
DESCRIPTION VALUE NOTES
Rated Capacity 30-500kWh -
Cell Capacity To suit equipment rating -
Minimum Voltage 240V -
Nominal Voltage 256V -
Maximum Voltage 320V -
Max Continuous ChargeCurrent
0.5C -
Duty Cycle 1 cycle per day -
Round Trip Efficiency >95% @ 23 ±3°C as a new product
Cell Cycle Life >4000 @ 23 ±3°C, 1C/1C, 80% DoD
Operational Temperature Optimal - 15°C to 50°C
Storage - - 15°C to 60°C
SPS | SINGLE PHASE & THREE PHASE STAND ALONE POWER SYSTEMS
Magellan SPS with Optional Outdoor Canopy