4
SPX LED WW LUMINAIRE QUICK START GUIDE 1 02.1704.0010 15 AUGUST 2018 SPX LED WW Luminaire QUICK START GUIDE Thank you for purchasing a Strand Lighting SPX LED WW Luminaire. We have designed this luminaire to provide you with a superior fitting in performance, design, and engineering. We are confident that it will perform to your expectations for many years to come. OVERVIEW This document provides installation and operation instructions for the following product(s): *excluding shutter and lens tube Accessories WARNINGS AND CAUTIONS Note: Installation is entirely at your risk. Do not attempt installation unless you are suitably qualified. Contact Strand Lighting or one of its authorized distributors for assistance. When using electrical equipment, basic safety precautions should always be followed including the following: Do not use outdoors. Do not mount near gas or electric heaters. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Do not use this equipment for other than intended use. Refer service to qualified personnel. INSTALLATION AND SETUP Power Requirements The SPX LED WW Luminaire requires standard AC power distribution from 100-240VAC, 50/60Hz. Power is 295W max, and current varies depending on the voltage. IMPORTANT AC POWER CONNECTION NOTES: Use only approved cable types. Do not overload circuits! Connecting Power Table 1 describes how to connect power to your SPX LED WW Luminaire. Part No. Name Description Weight* Dimensions* (H x W x L) 12610 SPX LED WW SPX LED WW - mains or DMX dimmable, warm white profile luminaire engine without lens tube 6.2 kg [13.67 lb] 414 x 327 x 380 mm [16.29 in x 12.91 in x 14.72 in] Part No. Description PCT1BE AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 without AC connector (bare end) PCT1GP AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Stagepin Connector PCT1GTL AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Twistlock Connector PCT1GR AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Edison Connector SC Clamp, Get-a-Grip 82003 Safety cable, black, 1/8 x 30 w/hook 2000851

SPX LED WW OVERVIEW Luminaire - Strand Lighting...SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018 A safety cable MUST always be used when rigging luminaires on

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SPX LED WW OVERVIEW Luminaire - Strand Lighting...SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018 A safety cable MUST always be used when rigging luminaires on

SPX LED WW LUMINAIRE QUICK START GUIDE 1 02.1704.0010 15 AUGUST 2018

SPX LED WW Luminaire

QUICK START GUIDE

Thank you for purchasing a Strand Lighting SPX LED WW Luminaire. We have designed this luminaire to provide you

with a superior fitting in performance, design, and engineering. We are confident that it will perform to your

expectations for many years to come.

OVERVIEWThis document provides installation and operation instructions for the following product(s):

*excluding shutter and lens tube

Accessories

WARNINGS AND CAUTIONS

Note: Installation is entirely at your risk. Do not attempt installation unless you are suitably qualified. Contact Strand Lighting or one of its authorized distributors for assistance.

When using electrical equipment, basic safety precautions should always be followed including the following:• Do not use outdoors.• Do not mount near gas or electric heaters.• Equipment should be mounted in locations and at heights where it will not readily be subjected to

tampering by unauthorized personnel.• The use of accessory equipment not recommended by

the manufacturer may cause an unsafe condition.• Do not use this equipment for other than intended use.• Refer service to qualified personnel.INSTALLATION AND SETUP

Power RequirementsThe SPX LED WW Luminaire requires standard AC power distribution from 100-240VAC, 50/60Hz. Power is 295W max, and current varies depending on the voltage.

IMPORTANT AC POWER CONNECTION NOTES:• Use only approved cable types.• Do not overload circuits!Connecting PowerTable 1 describes how to connect power to your SPX LED WW Luminaire.

Part No. Name Description Weight* Dimensions*(H x W x L)

12610 SPX LED WWSPX LED WW - mains or DMX dimmable,warm white profile luminaire enginewithout lens tube

6.2 kg [13.67 lb]

414 x 327 x 380 mm[16.29 in x 12.91 in x 14.72 in]

Part No. Description

PCT1BE AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 without AC connector (bare end)

PCT1GP AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Stagepin Connector

PCT1GTL AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Twistlock Connector

PCT1GR AC Power Input Cable (39 inches/1 meter), powerCON TRUE1 with Edison Connector

SC Clamp, Get-a-Grip

82003 Safety cable, black, 1/8 x 30 w/hook

2000851

Page 2: SPX LED WW OVERVIEW Luminaire - Strand Lighting...SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018 A safety cable MUST always be used when rigging luminaires on

SPX LED WW LUMINAIRE QUICK START GUIDE 2 02.1704.0010 15 AUGUST 2018

Table 1: SPX LED WW Luminaire AC Input Connections

Selecting Control and VoltageThe SPX LED WW operates on mains or on DMX. To run the fixture on mains, connect power from a dimmer. To run the fixture on DMX, connect power from a non-dimmed circuit and connect DMX. It is important to select the correct voltage for the luminaire to function correctly. To select the voltage, choose “120” or “230” using the voltage select switch on the rear of the fixture.

Connecting to the DMX512 NetworkBasic DMX512 installation consists of connecting multiple SPX LED WW Luminaires together (up to 30 luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX connector on the first luminaire. Another cable runs from the other DMX connector on the first unit to a DMX connector on the next luminaire (or DMX512 device to be controlled)For SPX LED WW Luminaire DMX Mapping, refer to the product user’s manual.

MountingThread clamp mounting bolt (with washer installed) through center clamp mounting hole at top of yoke and thread bolt into C-Clamp. Securely tighten bolt (by hand) into clamp. DO NOT OVER-TIGHTEN! C-clamp, bolt, and washer not included.

Luminaire MountingTo mount on a telescopic stand, reverse the yoke under the luminaire and bolt to stand. Note luminaire orientation for proper cooling.

Wire ColorPurpose Neutrik Marking

North America EU

White BrownMain / Line

(100 to 240VAC) L

Black Blue Neutral NGreen Green/Yellow Ground Ground Symbol

NOTE: Visit neutrik.com fordetailed wiring instructions forpowerCON TRUE1 connector.

Neutrik Connector

Power In

DMX In

Voltage Select

DMX Thru

DMX512 (out from first tosecond luminaire) DMX512 (out to the next luminaire

or DMX512 controlled device)

SPX LED Profile Luminaires

DMX512 Connections

Note: Remaining pins on each connector are not used.

DMX512 Signal XLR Pin

Common (Drain) 1DMX512 - 2DMX512 + 3

DMX512(from console orcontrol device)

Yoke Assembly

Center Clamp

Luminaire Cooling Vents

NOTE: To allow for proper cooling, make sure luminaire head is oriented as shown (with cooling vents pointed upwards).

C-Clamp (not included)

Flat Washer (not included)

C-Clamp Bolt (not included)

Mounting Hole

Page 3: SPX LED WW OVERVIEW Luminaire - Strand Lighting...SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018 A safety cable MUST always be used when rigging luminaires on

SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018

A safety cable MUST always be used when rigging luminaires on bars, truss, etc. A safety cable is recommended for all hanging installations and may be required by national and local codes. Loop or attach safety cable to luminaire safety cable anchor point as shown and attach to structure. You should always consult and follow all local and national codes and regulations for mounting and installation of luminaire.

OPERATING THE LUMINAIRETo set DMX address:

Step 1. At default screen, press LEFT or RIGHT arrow button once.

Step 2. Press LEFT or RIGHT arrow buttons to scroll to DMX Address.

Step 3. Hit [OK] to change DMX address.

Step 4. Press [ESC] at any time to access Main Menu.

Use with Mains DimmingIn order for the SPX LED WW to dim between 0% and 100%, the connected dimmer must provide a minimum voltage to ensure the fixture is powered and ready to dim. The minimum required voltage level is shown in the tables below. When the dimmer output falls below the specified minimum, the SPX LED WW powers off.For optimal performance, the dimmer should be configured to always generate the minimum required voltage level when the control signal from the console is at 0%. This can be achieved by adjusting the dimmer output law (sometimes refereed to as “dimmer curve,” “preheat” or “bottom set” depending on the manufacturer). Alternatively, it may be possible to produce the same effect by adjusting the output curve of your console. Consult the manufacturer of your dimmer/console for the specific steps required.

Note: Strand Lighting technicians cannot provide instructions for adjusting the output curve on dimmers/consoles not manufactured by Strand Lighting.

It is possible to use a dimmer or console that has not been adjusted. However, you may experience different performance characteristics and behaviors, including delays when flashing to full.

Beam Shutter OperationA safety cable MUST always be

used when rigging luminaires on bars, truss, etc. A safety cable is recommended for all hanging installation and may be required by national and local codes.

Safety Cable(sold separately)

Safety Cable(not supplied)

Safety CableAnchor Point

SAFETY CABLE: FOR LUMINAIRE, a safety cable is recommended for all hanging installations and may be required by national and local codes. Loop safety cable through luminaire safety cable anchor point. FOR LENS TUBE, attach a safety cable (sold separately) to lens tube anchor point and to yoke assembly.

0%10%20%30%40%50%60%70%80%90%

100%

0% 20% 40% 60% 80% 100%

Dim

mer

%

Output %

Dimmer % to Output % on 115V

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0% 20% 40% 60% 80% 100%

Dim

mer

%

Output %

Dimmer % to Output % on 230V

Page 4: SPX LED WW OVERVIEW Luminaire - Strand Lighting...SPX LED WW LUMINAIRE QUICK START GUIDE 3 02.1704.0010 15 AUGUST 2018 A safety cable MUST always be used when rigging luminaires on

SPX LED WW LUMINAIRE QUICK START GUIDE 4 02.1704.0010 15 AUGUST 2018

Lens Tube Removal and InstallationIt is easy and quick to change to the lens tubes on a SPX LED WW Luminaire. Fixed beam and zoom lens tubes are interchangeable.

CAUTION: Ensure the lens tube locking catch is fully engaged and safety cable is attached before putting fixture into use.

To remove and install lens tubes:

Step1.Loosen (but do not remove) move lens knob(s) towards front of lens tube assembly.

Step2.Slide lens tube locking catch forward.

Step3.Lift lens tube assembly up and away from light engine assembly.

Step4.To install perform process in reverse.

CUSTOMER SERVICEIf you have any questions regarding this product, please contact Customer Service at +1-214-647-7880 or via e-mail at [email protected].

LIMITED 3-YEAR WARRANTYStrand Lighting offers a three-year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery. A copy of Strand Lighting three-year limited warranty containing specific terms and conditions can be obtained from the Strand Lighting web site at www.strandlighting.com or by contacting your local Strand Lighting office.

Beam Shutters (4 Each)

Front View

Move beam shutters in and out as desired.

Shutter LockSee Detail

Shutter Lock Detail

Shutter Lock

Lens tube assemblyLens tube lock

21