FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kW Electric Heat The SPXB Series "Suite 20" is a compact, through-the-wall single package vertical HVAC unit that delivers conditioned air from a single unit to multiple rooms. The SPXB series is available in straight cool (SPXB) or heat pump (SPXB- HP) models. Having a small footprint (20" X 20") allows the SPXB to use a minimal amount of floor space. The SPXB installs easily into a closet having an exterior wall. Like your home, a standard wall mounted thermostat controls the SPXB unit. Applications for the SPXB include: • Hotels / Motels • High rise apartments / Condominiums • Assisted Living / Independent care facilities • Student housing • Manufactured / Modular buildings Standard Features: (see pages 4 and 5 for further information) Completely pre-charged with environmentally friendly R-410A refrigerant Easy access for in-place service of most components Multi-function micro-processor board that includes the following functions: Evaporator coil low temperature protection Low ambient lockout ECM motor utilized on SPXB18 & 24 models Random restart Compressor restart delay Front desk control capability Fan-off delay in the cooling mode Low voltage fuse protection Service disconnect Completely insulated cabinet for sound attenuation and weather infiltration Adjustable fresh air damper No tool needed to replace the filter Weight-supporting, single piece wall sleeves (except side access sleeves) for various wall thicknesses from 5" to 20" Sleeves have primary condensate drain connection with secondary overflow to building exterior All sleeves are shipped with a weather guard Flush type exterior architectural grilles Optional Features: (see page 8) Side access wall sleeves (rear access is standard) Custom painted exterior architectural grilles Hurricane grille / sleeve combinations Various louvered and non-louvered interior access panels Digital wall mount thermostats with high and low temperature limits (NEW!) Insulation Kit - Adds additional 5/8" insulation to three sides of the SPXB units. (see pages 5 & 8) "Rear install" shown

SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com

SPXB / SPXB-HP SeriesSingle Package Vertical Unit

Straight Cool and Heat Pump3/4 through 2 tons, up to 10 kW Electric Heat

The SPXB Series "Suite 20" is a compact, through-the-wall single package vertical HVAC unit that delivers conditioned air from a single unit to multiple rooms. The SPXB series is available in straight cool (SPXB) or heat pump (SPXB-HP) models. Having a small footprint (20" X 20") allows the SPXB to use a minimal amount of floor space. The SPXB installs easily into a closet having an exterior wall. Like your home, a standard wall mounted thermostat controls the SPXB unit. Applications for the SPXB include:

•Hotels/Motels •Highriseapartments/Condominiums •AssistedLiving/Independentcarefacilities •Studenthousing •Manufactured/Modularbuildings

Standard Features: (see pages 4 and 5 for further information) • Completelypre-chargedwithenvironmentallyfriendly R-410A refrigerant • Easyaccessforin-placeserviceofmostcomponents • Multi-functionmicro-processorboardthatincludesthe following functions: Evaporator coil low temperature protection Low ambient lockout ECMmotorutilizedonSPXB18&24models Random restart Compressor restart delay Front desk control capability Fan-off delay in the cooling mode Low voltage fuse protection • Servicedisconnect • Completelyinsulatedcabinetforsoundattenuationand weather infiltration • Adjustablefreshairdamper • Notoolneededtoreplacethefilter • Weight-supporting,singlepiecewallsleeves(except side access sleeves) for various wall thicknesses from 5" to 20" • Sleeveshaveprimarycondensatedrainconnection with secondary overflow to building exterior • Allsleevesareshippedwithaweatherguard • Flushtypeexteriorarchitecturalgrilles

Optional Features: (seepage8) • Sideaccesswallsleeves(rearaccessisstandard) • Custompaintedexteriorarchitecturalgrilles • Hurricanegrille/sleevecombinations • Variouslouveredandnon-louveredinterioraccess panels • Digitalwallmountthermostatswithhighandlow temperature limits • (NEW!) Insulation Kit -Addsadditional5/8"insulation to three sides of the SPXBunits.(seepages5&8)"Rear install" shown

Page 2: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

SPXB SeriesCooling Only

(1) Testedat95°FDB/75°FWBoutdoorsand80°FDB/67°FWBindoors.

(2)TestedinaccordancewithAHRIStandard390.

(1) Factory Settings: (H) = Heating, (C) = Cooling

Inkeepingwithitspolicyofcontinuousprogress and product improvement, First Co. reserves the right to make changes withoutnotice.MaintenanceforallFirstCo. products is available under “Product

Maintenance”atwww.firstco.com.

A B C FILTER

9,12,18SPXB 6-1/2 6-1/8 66-1/2 18x24x1

24SPXB 10 2-1/2 68-1/2 18x26x1

COOLING / PERFORMANCE DATA

UNIT MODEL

STANDARD RATING (1) EER

BTUH

9SPXB 9000 10.0

12SPXB 11400 10.0

18SPXB 17500 10.0

24SPXB 21400 10.0

BLOWER DATA

UNIT MODEL

MOTOR SPEED

CONN. (1)

CFM vs EXTERNAL STATIC PRESSURE

0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40

9SPXBHIGH

MED(H&C)LOW

490390310

480380300

465370290

450360280

440350270

430340260

420330245

410320230

12SPXBHIGH

MED(H&C)LOW

490400310

480390300

470380290

460370280

450360270

440350260

425335250

410320240

18SPXBHIGH

MED(C)LOW (H)

740670560

730660550

715645545

700630530

685615515

670600500

650585485

630570470

24SPXBHIGH

MED(C)LOW (H)

885760730

875750720

870740710

860730700

850725695

840715685

830700675

820690665

ELECTRICAL DATA (208/230V-1PH-60Hz)

UNIT MODEL

ELECTRIC HEAT DATA BLOWER DATA CONDENSER DATA MINIMUMCIRCUIT

AMPACITY

MAXIMUMCIRCUIT

PROTECTIONSHIPWT.

kW BTUHTOTAL HEATING

AMPSEVAPORATOR

MOTORCOMPRESSOR

CONDENSERMOTOR

240V 208V 240V 208V 240V 208V AMPS HP RLA LRA FLA HP 208V 240V 208V 240V

9SPXB

-0-2-3-4

0234

01.5

2.253

06800

1020013600

051007700

10200

0.09.113.217.4

0.07.911.515.1

.72 1/8 4.4 25 .50 1/15

7101519

7121722

15151520

15152025

245

12SPXB

-0-2-3-4-5

0234

4.5

01.5

2.253

3.38

06800

102001360015400

051007700

1020011500

0.09.1

13.217.419.5

0.07.911.515.116.9

.72 1/8 4.7 25 .72 1/10

810151922

812172225

1515152025

1515202525

245

18SPXB

-0-2-3-4-5-6-8-10

0234

4.5689

01.5

2.253

3.384.56.0

6.75

06800

102001360015400205002730030700

051007700

1020011500154002050023000

0.09.2

13.417.619.725.934.238.4

0.08.111.715.317.122.529.833.4

.87 1/8 7 38 2.3 1/14

1212152022293842

1212172225334348

2020202025304045

2020202525354550

255

24SPXB

-0-3-4-5-6-8-10

034

4.5689

02.25

33.384.56.0

6.75

0102001360015400205002730030700

07700

1020011500154002050023000

0.015.319.521.627.836.240.3

0.013.717.319.124.531.735.3

2.8 1/3 13.5 58.3 2.3 1/4

22222224314045

22222527354651

30302525354045

30303030355060

255

DUCT OPENING

1A

B

FILTER

ELEMENT

BLOWERMOTOR

CONDENSEROUTLET

CONDENSERINLET

20

C

41-1/4

20 20

LOWVOLTAGE

ELECTRICALKNOCKOUT

SERVICE PULLOUT

RETURN AIR

6-5/810-1/4

- 2 -

Page 3: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

SPXB-HP SeriesHeat Pump

(1) 47°FDB/43°FWBoutdoor,70°FDB/60°FWBindoor.

NOTE:Compressors in these models do not operate simultaneously with heater elements.

(1) 95°FDB/75°FWBoutdoor-80°FDB/67°FWBindoor.(2)TestedinaccordancewithAHRIStandard390.

ELECTRICAL DATA (208/230V-1PH-60Hz)

UNIT MODEL

ELECTRIC HEAT DATABLOWER

DATACONDENSER DATA

MINIMUMCIRCUIT

AMPACITY

MAXIMUMCIRCUIT

PROTECTIONSHIPWT.kW BTUH

TOTAL HEATING

AMPS

EVAPORATORMOTOR

COMPRESSORCONDENSER

MOTOR

240V 208V 240V 208V 240V 208V AMPS HP RLA LRA FLA HP 208V 240V 208V 240V

9SPXB-2-3-4

-HP234

1.52.25

3

68001020013600

5100770010200

9.113.217.4

7.911.515.1

.72 1/8 4.4 25 .50 1/15101519

121722

151520

152025

245

12SPXB

-2-3-4-5

-HP

234

4.5

1.52.25

33.38

6800102001360015400

510077001020011500

9.113.217.419.5

7.911.515.116.9

.72 1/8 4.7 25 .72 1/10

10151922

12172225

15152025

15202525

245

18SPXB

-2-3-4-5-6-8-10

-HP

234

4.5689

1.52.25

33.384.56.06.75

6800102001360015400205002730030700

510077001020011500154002050023000

9.213.417.619.725.934.238.4

8.111.715.317.122.529.833.4

.87 1/8 7 38 2.3 1/4

12152022293842

12172225334348

20202025304045

20202525354550

255

24SPXB

-3-4-5-6-8-10

-HP

34

4.5689

2.253

3.384.56.06.75

102001360015400205002730030700

77001020011500154002050023000

15.319.521.627.836.240.3

13.717.319.124.531.735.3

2.8 1/3 13.5 58.3 2.3 1/4

222224314045

222527354651

302525354045

303030355060

255

DUCT OPENING

1A

B

FILTER

ELEMENT

BLOWERMOTOR

CONDENSEROUTLET

CONDENSERINLET

20

C

41-1/4

20 20

LOWVOLTAGE

ELECTRICALKNOCKOUT

SERVICE PULLOUT

RETURN AIR

6-5/810-1/4

Inkeepingwithitspolicyofcontinuousprogress and product improvement, First Co. reserves the right to make changes withoutnotice.MaintenanceforallFirstCo. products is available under “Product

Maintenance”atwww.firstco.com.

A B C FILTER

9,12,18SPXB-HP 6-1/2 6-1/8 66-1/2 18x24x1

24SPXB-HP 10 2-1/2 68-1/2 18x26x1

BLOWER DATA

UNIT MODELMOTOR SPEED

CONN. (1)

CFM vs EXTERNAL STATIC PRESSURE

0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40

9SPXB-HPHIGH

MED(H&C)LOW

490390310

480380300

465370290

450360280

440350270

430340260

420330245

410320230

12SPXB-HPHIGH

MED(H&C)LOW

490400310

480390300

470380290

460370280

450360270

440350260

425335250

410320240

18SPXB-HPHIGH

MED(C)LOW (H)

740670560

730660550

715645545

700630530

685615515

670600500

650585485

630570470

24SPXB-HPHIGH

MED(C)LOW(H)

885760730

875750720

870740710

860730700

850725695

840715685

830700675

820690665

COOLING / PERFORMANCE DATA

UNIT MODEL

STANDARD RATING (1) EER

BTUH

9SPXB-HP 8700 10.0

12SPXB-HP 11400 10.0

18SPXB-HP 17500 10.0

24SPXB-HP 21100 10.0

HEATING / PERFORMANCE DATA (3)

UNIT MODEL

STANDARD RATING (1) COP

(47o)BTUH

9SPXB-HP 8500 3.0

12SPXB-HP 10300 3.0

18SPXB-HP 15400 3.0

24SPXB-HP 19200 3.0

- 3 -

(1) Factory Settings: (H) = Heating, (C) = Cooling

Page 4: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

FEATURES AND BENEFITS

1. Solid State Circuit Board -Incorporatesthefollowingcontrolfeatures:

• Evaporator coil low temperature protection –Duringthecoolingmode,shouldtheevaporatorcoilexperienceeither a low temperature condition that could result in ice build up on the coil or a reduced air flow situation, a temperaturesensorattachedtothecoilwillde-energizetheSPXBunit.Thesensorwillre-energizetheSPUunit when the coil warms back up.

• Low ambient lockout – Locks out compressor when the sensor registers temperatures of 40 degress F and below to extend compressor life.

• Random restart – When power is turned on after a power outage, a built-in random restart (3 to 4 minutes) prevents all compressors from restarting simultaneously.

• Compressor restart delay – This delay ensures that system pressures are allowed to equalize before acompressor restart, which extends compressor life.

• Front desk control – When wired to a front desk console, each unit can then be enabled or disabled from the front desk, thus saving the energy used to condition unoccupied rooms.

• Fan delay – A fan delay allows the evaporator blower to continue running for up to 45 seconds after the thermostat issatisfied.Thisfeaturemaximizescoolingperformance.

• Low voltage fuse protection

2. Service Pullout - Factory installed for service convenience and maintenance.

3. Adjustable fresh air (manual) - To meet code requirements for fresh air introduction. When opened, the fresh airvent(seeFigure8)allowsupto50CFMofoutsideairtobeintroducedintotheequipmentcloset.Theairthenmixes with return air entering the closet through the return air grille.

4. Wall-mounted thermostat –(See“accessories”,P.8)TheSPXB is easily controlled by a standard low voltage wall thermostatratherthancomplicatedunit-mountedcontrols.Lowvoltagewiresare“stubbed”outtheleftsideofthecabinet.

5. 40VA transformer

Figure 1 - General Assembly

Filter

ElectricalDisconnect

Rear AccessPanel

Electrical ServiceKnockout

Drain(3/4" MPT)

Outside

Wall Sleeve(See P.8)

Sleeve Seal

ArchitecturalGrille

(See P.8)

Rough-in Dimensions44"H X 21-5/8"W

ApproximateFastenerLocations

- 4 -

Page 5: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

FEATURES AND BENEFITS (CONT.)

SHOWN WITH OPTIONAL LOUVERED ACCESS PANEL (See P.8)

NOTE: A solid door or panel in front with a side wall return air grill will result in lower sound levels.

Figure 25. Wall Sleeve – (See Figures 1, 4 and 5) Rear or side install

wall sleeves are provided for installation during rough-in and, when ready, the SPXB unit is simply slid into the sleeve and the ductwork and electrical connected. The sleeve is a weight-bearing sleeve that supports the entire weight of the SPXB unit and provides a weather tight seal against wind andwaterinfiltration.A3/4”maleNPTfittingisprovidedinthe bottom of the sleeve for field connection to a condensate riser. Four wall sleeve depths are available to accommodate wallthicknessfrom5”to20”.Eachsleeveincludesafactoryinstalled“weatherguard”tocoverthesleeveopeningduringconstruction.

6. Unique “Sleeve Drain” Condensate System - (Also see Figure 4) A factory installed drain line connects the evaporator drain pan to a vertical pipe connection in the SPXB base pan. Evaporator condensate is delivered from

the SPXB unit to a catch tray in the wall sleeve and exits the sleeve through the3/4”maleNPTfitting.Thisdesignallows the plumber to completely pipe the drain to a condensate riser during the rough-in stage, thus eliminating condensate connection problems usually encountered when trying to connect the HVAC drain to the riser after the HVAC unit is installed in the closet. This features also allows the SPXB unit to be removed for service without disconnecting the condensate

piping! This configuration does not require any additional closet space to make the drain connection, as do some competitive products.

7. Secondary overflow: Ifforanyreasontheprimarycondensate riser becomes clogged, water will fill the catch tray and then be diverted through the sleeve to the exterior of the building, rather than be allowed to overflow into the closet or living area. Rain water entering the sleeve is automatically diverted to the 3/4" sleeve drain.

8. Ductable return air – Return air can be ducted to the unit. However, most installations would not normally require ducted return air.

9. New “Flush Style” Architectural Grille – (See Figure 6) This new grille is an attractive extruded aluminumarchitectural grille that attaches to the outside face of the wall sleeve. The blades of this unique grille recess into the wallsleeveforaneat,“flush”appearance.Grilles installfrom the insideofthewallsleeve.Donot install the SPXB unit into the sleeve before installing the grille.

10. Filter Brackets – (SeeFigure7)FilterBracketsandthrowaway filter are shipped with each unit and are field installed over the unit’s evaporator coil.

11. Insulation kit (#91K01) - The interior of all SPXB's is lined with 1/2" fiberglass as standard. The 91K01 kit is designed to be used in any application where additional insulation is desired.Thekitincludesthreesectionsof5/8"foilfacedductboard insulation that are screwed together in the field and cover the three sides on the condenser section.

Figure 3

Return Air

CondenserAirInlet

Conditioned Air

CondenserAir

Outlet

“Rear Install”sleeve shown

- 5 -

Page 6: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

FIGURE 7

Filter Bracket Detail

Ducted ReturnAir Flanges

ThermostatWiring

Fresh AirVent

Filter Clip

Service Pullout Filter

Bracket

Side Install SleeveNote:Separate wall mounting bracket is shipped with “side install” wall sleeves.

FIGURE 5

(Unit shown with “Rear Install” sleeve )FIGURE 6

ReturnAir

SPXB Unit

Tilt Sleeve 1/2 Bubble to outside

6” min.

To CondensateDrain

1/4”min.

Note:“P”Trapisshownforillustrationpurposesonly-Itmay not be required by local codes.

CAULK

FIGURE 4

Side View(with “Rear Install” sleeve)

UNIT / SLEEVE DIMENSIONS

Part Number

Rear Install Side Install Fits Wall Thickness

A B C

936-1B 936-11B 5”-8”wall 9” 17-1/2” 26”

936-2B 936-12B 8”-12”wall 13” 17-1/2” 30”

936-3B 936-13B 12”-15”wall 16” 17-1/2” 33”

936-4B 936-14B 15”-20”wall 21” 17-1/2” 38”

- 6 -

Page 7: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

Oneendofa3”aluminumventpipeisconnectedto the condenser venturi and the other end is connected to the side of the SPXB cabinet. A mesh screen is installed inside the vent pipe and a metal plate on the side of the cabinet covers theopeningoftheventpipe.Upto50CFMoffresh air is introduced into the equipment closet by removing the metal cover plate. The fresh air then mixes with the return air and is then pulled through the evaporator coil and into the supply duct. The cover plate can be re-installed to par-tially close the fresh air opening if less than 50 CFMisdesired.Anexternalsourceofnegativepressure (i.e. a bathroom fan) could be used to introducemorethan50CFMoffreshair.Consultwith factory for further details.

FIGURE 8

Grille width is 22” or 22-3/4”

Unit must line up with door opening to facilitate removal when necessary

Notes:1. Sleeverough-inopeningis44”(H)X21-5/8”(W).2. Bottomofopeningshouldbeapprox.6”abovefloorlevel.3. Minumum3”ofclearanceisrequiredonallsidesofthe SPXB unit.

Instructions: Tofindtheminimumclosetdepth(dimension“C”),usethe following method:

Determinedimension“A”whichisthetotalfinishedwall thickness.

-For5”-8”outsidewallthickness,subtract“A”from29”. (“C”=29-“A”)

-For8”-12”outsidewallthickness,subtract“A”from33”. (“C”=33-“A”)

-For12”-15”outsidewallthickness,subtract“A”from36”. (“C”=36-“A”)

SPXB Closet Dimensions - Rear Installation

SPXB Rear Installation Detail

SPXBUNIT

Wall Sleeve Outside WallInstructions: Tofindtheminimumclosetdepth(dimension“C”),usethefollowingmethod:

Determinedimension“A”whichisthetotalfinishedwallthickness.

-For5”-8”outsidewallthickness,subtract“A”from39”. (“C”=39-“A”)

-For8”-12”outsidewallthickness,subtract“A”from43”. (“C”=43-“A”)

-For12”-15”outsidewallthickness,subtract“A”from46”. (“C”=46-“A”)

SPXB Closet Dimensions - Side Installation

Notes:1. Sleeverough-inopeningis44”(H)X21-5/8”(W).2. Bottomofopeningshouldbeapprox.6”abovefloorlevel.3. Minumum3”ofclearanceisrequiredonthesidesoftheSPXBunitand12”clearanceontherearoftheunit.

SPXB

UN

IT

- 7 -

Page 8: SPXB / SPXB-HP Series - First Co · 2018-07-09 · FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - SPXB / SPXB-HP Series Single Package

ACCESSORIES (sleeves, louver, and thermostat required for each installation)

ACCESSORY DESCRIPTIONDIMENSIONS

(HXWXD)PART NUMBERS SHIP WT. (EA)

STANDARD SLEEVES HURRICANE (5)

REAR INSTALL(non-Hurricane)

SIDE INSTALL (3)(non-Hurricane)

REAR INSTALL SIDE INSTALL REAR SIDE

WALL SLEEVES(2)

For5”-8”thickwallsFor8”-12”thickwallsFor12”-15”thickwallsFor15”-20”thickwalls

43-3/4x21-3/8x2643-3/4x21-3/8x3043-3/4x21-3/8x3343-3/4x21-3/8x38

936-1B936-2B936-3B936-4B

936-11B936-12B936-13B936-14B

936-1H936-2H936-3H936-4H

936-11H936-12H936-13H936-14H

59 (4)63(4)68(4)75(4)

64(4)68(4)73(4)80(4)

ARCHITECTURALGRILLES

Custom Painted

For Field PaintingAnodizedAluminum

Standard 44 x 22 G205S (1) G205PPA G205A - - - 12

Hurricane 45-5/8x22-3/4 G215S (1) G215P G215A - - - 22

THERMOSTATS

Straight Cool (24V)Digital

cool - off - heat, auto - onw/limits-(6-wire)

4 x 5(Horizontal)

T1020NC - - - - - -

Heat Pump (24V)Digitalw/emergencyheatcool - off - heat, auto - on

w/limits-(6-wire)

4 x 5(Horizontal)

T1220NC - - - - - -

Programmable (5-2)st. Cool/Ht. Pump (24V)cool-off-heat, auto-onw/em.Ht.&limits(6-

wire)

4 x 5(Horizontal)

T2220NC - - - - - -

NOM.CAPACITY(CLG.)

ELECTRICHEAT

0 = 0 kW @ 240V3 = 3 kW @ 240V5 = 5 kW @ 240V6=6kW@240V8=8kW@240V

10 = 10kW @ 240V

9-9,000BTUH12-12,000BTUH18-18,000BTUH24-24,000BTUH

SERIES

SPX-SLIMVERTICALPTAC

VERSION

HP-HEATPUMPNOLETTERS-STRAIGHTCOOL

MODEL NUMBER NOMENCLATURE

Catalog No. SPXB718 replaces SPXB318

NOTES:(1) Includes18x24x1filter.(2) Requires external return air grille and unit mount filter.(3) Bothpanelsareinsulatedforsoundreductionandhavetamperproofscrews.(4) Panels are shipped ten per carton.

NOTE: A solid door or panel with a side wall return air grille will result in lower sound levels.

NOTES:(1) “S”indicatescustomcolor,tobeprovidedbycustomer.Minimumorderquantityis20percolor.(2) Rear install application provides better access to the SPXBunitandisrecommendedover“sideinstall”whereverpossible.(3) Sideinstallapplicationrequiresdifferentclosetsizeandconfiguration.(SeeP.7)Contactfactoryforfurtherinformation.(4) All wall sleeves are shipped two (2) per carton.(5) Hurricanesleevesrequirespecialgrille(see“ArchitecturalGrilles”above) (contact the factory for information about hurricane sleeves and grilles)

OPTIONAL ACCESSORIES (field installed)

COMPONENT DESCRIPTIONDIMENSIONS

(H X W)PART

NUMBERSHIPWT.

ACCESS/RETURNAIRPANEL(3)(4)

LOUVERED(1)

FRAME OPENING

931-11 5587X31 84X28

NON-LOUVERED(2) 87X31 84X28 931-12

LOUVERED(1) 82X31 79X28 931-1355

NON-LOUVERED(2) 82X31 79X28 931-14

INSULATIONKIT 5/8"DUCTBOARD N/A 91K01 ---

“A”“B”FRAMEDOPENING

INSIDE

31.00

28.00FRAMED OPENING INSIDE

PART NO. “A” “B”

931-11 87.00 84.00

931-13 82.00 79.00

18SPXB5-HP

- 8 -

(91K01)