WAYFINDING TEAM
St. Cloud State UniversitySt. Cloud, Minnesota
EXTERIOR DESIGN INTENT DOCUMENT
06.12.2015 Final
St. Cloud StateUniversity720 4th Ave. SouthSt. Cloud, MN 56301
John FrischmannDirector of Facility [email protected]
Loren J. BooneAsst. VP, [email protected]
Corbin Design109 E. Front StreetTraverse City, MI 49684(P) 231.947.1236(F) 231.947.1477www.corbindesign.com
Robert Brengman, [email protected]
Jeff Frank, Senior [email protected]
Mary Lou Piehl, Project [email protected]
EXTERIOR SIGN TYPE ARRAY 3
FABRICATION SPECIFICATIONS 7
GRAPHIC STANDARDS 10
DESIGN INTENT DRAWINGS 11
Gx-1 Entrance Identifier/Guide 12
Gx-1a Large Boundary Marker 13
Gx-1b Small Boundary Marker 14
Gx-2 Entrance Identifier/Guide with LED Message Board 15
Gx-4 Vehicular Roundabout Guide 6 inch Copy 16
Gx-5 Primary Vehicular Guide 17
Gx-6 Secondary Vehicular Guide 18
Ix-1a Building Identification, Freestanding Overhead 19
Ix-1b Building Identification, Freestanding Low 20
Ix-2 Building Identification, Wall Mounted Large 21
Ix-3 Bulding Identification, Wall Mounted Small 22
Ix-5 Parking Lot Identification 23
Ix-6 Custom Parking Garage Identification 24
Ix-7 Pedestrian Bridge Branding 25
Ix-8 Campus Identification (retrofit) 26
Dx-1 Pedestrian Map Kiosk 27
Dx-2 Pedestrian Map Kiosk (retrofit) 28
Vx-1, Vx-2 & Vx-3 Vinyl on Glass 29
Rx-1 and Rx-2 Regulatory and Accessible Entrance Guide 30
MNDOT Sign Layouts 31
TABLE OF CONTENTS
2
St. Cloud State University – Exterior Sign Array
6th STREET ENTRANCE
Student Center
Learning Resource Center
Front view
Athletic Complex
6th Street South
Front view
Atwood Memorial Center
Performing Arts Center
Entrance Identifier/GuideIlluminated
Gx-1 Gx-2 Gx-1b
Entrance Identifier/Guide (LED)Illuminated
Gx-1a
Boundary Marker, LargeNon-illuminated
Boundary Marker, SmallNon-illuminated
Side View
Top View
Double-sidedWatchfire LED screens
4th Ave S Pay Ramp
1'-5"
6'-8 1/2"
10'-5"
10'-10"
2'-10"
6'-8"
3
St. Cloud State University – Exterior Sign Array
Atwood CenterPerforming Arts CenterLearning Resource CenterAdministrative Services
Gx-5 Gx-6 Dx-1
Option 1
Option 2Option 3
Vehicular Guide, PrimaryReflective Message
Gx-4
Vehicular Guide, Roundabout6" cap height, Reflective Message
Vehicular Guide, SecondaryReflective Message
Pedestrian Map Kiosk
Back ViewFront View
Alternate back images
Top View
NorthCampus
Brown Hall
Riverview
Wick Science Building
2nd Ave S Pay Lot 2nd Ave S Pay Lot
Atwood Memorial Ctr
AthleticComplex
7'-4"
4'-6"
5'-8"
2'-1 1/2"
7'-5"
4
St. Cloud State University – Exterior Sign Array
455 1st Ave S
NorthBenton Hall
BTH
400
LearningResource Center
MC
Centennial HallBookstore
Herberger Business School
CH
Dx-2 Ix-1a Ix-1b Ix-2 Ix-3
Top View
Top View
Top View
Retrofit Existing Kiosk Building Identifier, LowPost and Panel
Non-illuminated
Building Identifier, Pole Mount FlagNon-illuminated
Building IdentifierBuilding Mounted, Large
Non-illuminated
Building IdentifierBuilding Mounted, Small
Non-illuminated
577Garvey Commons
GC
Existing structure
6th St S
1st Ave S
201 1st Ave S
6'-5"
4'-1"
4'-0"
5'-1"
3'-9"
10'-5 1/2"
2'-6"
9'-1"
2'-4 1/2"
1'-7 1/2"
5
St. Cloud State University – Exterior Sign Array
P LotEmployee ParkingPermit Required
Mon-Thur 7am-7pm Fri 7am-3pm
NO PARKING 3AM-7AM
Enforced Year Round
Ix-5 Vx-1 Rx-1
Parking Lot Identifier/TrailblazerReflective Message
Ix-7
Pedestrian Bridge Branding
Ix-8
Campus Identification (retrofit)
Ix-6
Parking Ramp Identifier (Retrofit)
Vinyl on GlassBuilding Identification
Vx-2
Vinyl on GlassBuilding Identification
with Building Connector Path
Vx-3
Vinyl on GlassBuilding
Connector Path
Regulatory
PA
Y L
OT
6thST SOUTH
PUBLIC SAFETY CENTER4th Ave South Parking Ramp
910Engineering andComputer Center
ECC910Engineering andComputer Centerr
ECC
RESERVEDFOR
VISITORS
Rx-2
AccessibleEntrance
Rx-3
Staff/StudentParking Lot
Identification
BuildingConnector
Path
Access to Building Connector Path
3rd Ave S 3rd Ave S
10'-10"
2'-5"
1'-0"
1'-6"
5'-7"
7'-7"
9"
4'-2"
6
A. Quality StandardsThe materials, products, equipment and performance specifications described within establish a standard of required function, dimension, appearance, performance and quality to be met by the Fabricator. B. Structural DesignDetails on design intent drawings indicate a design approach for sign structure but do not necessarily include all fabrication details required for the complete structural integrity of the signs, including consideration for static, dynamic and erection loads during handling, erecting, and service at the installed locations, nor do they necessarily consider the preferred shop practices of the individual Fabricators. Therefore, it shall be the responsibility of the Fabricator to perform the complete structural design and engineering of the signs and to incorporate all the safety features necessary to adequately support the sign for its intended use and purpose and to protect SCSU. Fabricator shall also be responsible for ensuring that all signs meet local, state and federal codes.
C. Vandalism DesignFabrication and installation design is to withstand severe abuse and souvenir theft vandalism, but not less than the equivalent of resisting simple hand implements and tools (screwdrivers, knives, coins, keys, and similar items), and adult physical force. All hardware and fasteners within reach shall be vandal resistant.
D. SubstitutionNo substitution will be considered unless SCSU has received written request for approval. Fabricator may recommend equal or better equipment or method, but will be required to provide full documentation establishing such a substitu-tion’s equality or superiority as measured in the following:
• compliance with the visual design intent;
• cost;
• ease of maintenance; and
• performance.
The burden of proof of the merit of the proposed substitute is upon the Fabricator. SCSUs decision of approval or disapproval of a proposed substitution shall be final.
E. Material HandlingThe Fabricator is to pack, wrap, crate, bundle, box, bag, or otherwise package, handle, transport, and store all fabricat-ed work as necessary to provide protection from damage by every cause. Fabricator shall provide clear and legible identifying information on all product packaging to ensure proper on-site identification and installation.
F. Sign Specifications: Construction MethodologyThe drawings call for a variety of fabrication techniques. Fabricators are given leeway to fabricate the signs to meet the intent of the designs depicted by the drawings.
1. Because different systems of extrusions may result in slightly different dimensional requirements, the total height and width dimensions described in the signconstruction on the drawings may be considered “nominal” for the purposes of cost quote.
2. Sign faces are to be fabricated using aluminum plate of varying thicknesses, as specified on design intent drawings, with a minimum thickness of .125" unless otherwise noted.
3. Unless otherwise noted on the design intent drawings, all cut-out push-through copy is to be routed from a single sheet of white acrylic, with a minimum thickness of 3/8" and pushed through 1/16". Routed letters and shapes that are bonded to a separate acrylic sheet are not acceptable; they must be routed from a single sheet.
• Acrylic is to be attached to the back of the sign using adhesive, mechanical fasteners, or both depending on the design specifications.
• All letter knock-outs (interior of letter forms) are to be stud mounted through the acrylic.
• When illuminating the acrylic face with Fluorescent or Neon, 7328 shall be the standard white acrylic.
• When illuminating the acrylic face with LED, 2447 shall be the standard white acrylic.
• Acceptable spacing between the push-through acrylic and the cut-out aluminum is 1/32" to 1/16" depending on the copy height (if the copy is larger than 32", alternate spacing may be used to allow for the change in material expansion).
4. Sign cabinet seams shall be sealed to ensure they are watertight.
5. All finishes are to be satin finish, free from fading, peeling or cracking. Paint preparation of all exterior metal surfaces of the sign to include removal of all scratches and imperfections, sanding and chemical etching. Substrate cleaning, preparation, paint application and paint thick-ness to be in strict compliance with Matthews Paint or AkzoNobel published recommendations. Acceleration of the drying process is not allowed. Clear final top coat is required
6. Except where approved otherwise by SCSU, conceal fasteners.
7. Any sign faces smaller than 8’ by 20’ are to be fabricat-ed from 1 piece of seamless material.
8. On welded joints, dimensional and structural welding defects will not be accepted, including but not limited to: poor weld contours, including excessive bead convexity and reinforcement, and considerable concavity or under-sized welds; cracks; undercutting; porosity; incomplete fusion; inadequate penetration; spatter; and non-metallic inclusions. Welding is to be performed by AWS (or similar) certified personnel, following AWS Standard Welding Procedure Specifications (SWPSs) for steel, aluminum, and stainless steel as appropriate.
9. Non-welded joints between various portions of signs must have a tight, hairline-type appearance, without gaps. Provide sufficient fastenings to preclude looseness, racking, or similar movement.
10. Provide drain holes as needed to prevent accumula-tion of water within signs. Holes must be inconspicuous and be in inconspicuous locations; holes must be located such that drainage does not occur onto signs, or other surfaces subject to staining. Provide internal system of baffles to prevent “light leaks” through drain holes of illuminated signs. Provide color-coordinated insect screening over drain holes.
11. Non-illuminated sign faces are to have lettering and graphics created as silk-screening or as surface-applied vinyl typography using Oracal exterior grade, minimum 5-year warranty, as noted in the design intent drawings.
12. Visible metal joints must adhere to a fit tolerance of .01".
13. Unlit channel letter faces must be .25" aluminum. Channel letter returns must be .080" aluminum.
G. Sign Specifications: Illumination & ElectricalIt shall be the responsibility of the Fabricator to perform the complete electrical design for illuminated signs. Illuminated signs shall be designed by an electrical engineer and shall be fabricated and wired to be compliant with current UL listing requirements, and shall be UL certified.
1. All internally illuminated sign cabinets are to have an access panel that is tight fitting, lightproof and water-proof. Access panels are to be in an accessible location, out of sight, and shall be shown on shop drawings.
2. Internally illuminated signs are to have an adequate internal system of ventilation to assure a uniform dissipa-tion of heat from electrical components of electrically powered and illuminated signs, heat (solar) absorption by sign and other sources. Any openings in exterior surfaces
must be internally baffled to prevent light leaks and prevent entry of rain, snow, wind-blown debris, and other foreign matter, and are to be covered with interior color-coordinated insect screen.
3. Only labels required by law are permitted to be mounted on the exterior of the sign face, and they shall be located in a position that is as discreet as possible.
4. All internally illuminated interior metal surfaces shall be painted white using Matthews’ reflective white paint, or shall be lined with 3M’s Matte White Light Enhance-ment Film, to enhance and evenly distribute light.
5. All electrical components shall be built to be housed within sign cabinets. All wiring and raceways within the sign are to be completely enclosed. Internal illumination by LED is required to provide adequate and even illumina-tion over the face of the sign without hot spots or shadows. “Halo” effects, “spreading” or similar light spill due to excessive transmission of the backlight source shall be minimized.
6. Illumination to be provided by LED as specified on design intent drawings. Internal hardware must not be visible through the translucent letterforms and graphics.
7. All internally illuminated exterior signs are to have their own electric eye on/off control to turn the sign on at night and off in the morning, unless SCSU specifies a need for a timer. Location of eye to be shown on shop draw-ings.
8. Verify location of power provided by others prior to sign fabrication.
9. Face-lit channel letters with a 16" or shorter cap height shall be trimless. Face-lit channel letters taller than 16" may use a low-profile trim cap. Internally illuminated channel letters shall be illuminated using LED, unless otherwise noted on the design intent drawings. Trans-formers for channel letters shall be remote transformers wherever possible. If remote transformers are not applica-ble, then all electrical components shall be contained within the channel letter itself. Raceways are not accept-able unless specifically noted on the design intent drawing or if approved by SCSU. All raceways must be painted the same color as the wall on which the sign will be mounted. Channel letters to be painted on the inside with Matthews’ reflective white paint, or lined with 3M’s Matte White Light Enhancement Film to enhance and evenly distribute light.
I. Fonts/TypefacesThe fonts used for this project were selected specifically for this project by SCSU, and include those listed in the graphic standards. It is the responsibility of the fabricator to purchase the fonts.
No substitution of any other typefaces may be made. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composi-tion unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
1. All letterforms, symbols or graphics shall be repro-duced either by photographic or computer-generated means. Hand-cut characters are not acceptable. Cutting shall be done in such manner that edges and corners of finished letterforms will be sharp and true. Letterforms with nicked, cut, ragged, rounded corners, and similar disfigurements will not be acceptable.
2. All letterforms shall be made from material and gauge as indicated on design intent drawings. Typefaces shall be replicated as indicated on the drawing.
3. Ligatures are to be turned off.
4. Apostrophes are to be used, not footmarks. Note that there is a difference in most fonts.
5. Silk-screened and vinyl copy is to match the sheen of the copy panel background (satin). Edges of letters shall be straight and corners sharp. Surface of letters shall be uniform in color finish, and free from pinholes and other imperfections.
6. Silk-screened images shall be executed with photo screens prepared from original art. No hand-cut screens will be accepted. Original art shall be defined as artwork that is a first generation reproduction of the specified art.
7. Silk-screening shall be highest quality, with sharp lines and no sawtooths or uneven ink coverage. Screens shall be photographically produced. Application of inks through screens shall consist of one flood pass and one print pass. Images shall be uniform in color and ink thickness. Images shall be free from squeegee marks and lines resulting from improper print stroke or screen off contact height. Signs shall be placed in adequate drying racks with minimum of 2 inches between racks for ample airflow. Sign racks shall have system of forced airflow between layers to provide proper drying and curing of inks. After signs have dried completely according to the ink manufac-turer’s time allowance, signs may be packaged.
8. The edges and corners of routed letterforms shall be sharp and true. Letterforms with nicked, cut, ragged, rounded (positive or negative) corners, and similar disfigurements will not be acceptable.
9. Letterforms shall be aligned so as to maintain a base line parallel to the sign format, with margins and layout as indicated on design intent drawings and approved shop drawings. Vertical strokes shall be plumb.
10. Vinyl graphics and letterforms shall be computer-cut.
J. Permits and VariancesFabricator shall be knowledgeable of relevant local code requirements and honor same in fabrication and installa-tion. Where applicable, it is the responsibility of the Fabrica-tor to secure any and all necessary permits for signage installation. It is the responsibility of SCSU to secure varianc-es, should any be required. It is SCSU’s responsibility to call the appropriate agency to have all underground utilities properly located and marked. Any damage to below-grade utilities or structures for which SCSU has provided adequate location information is the responsibility of the Fabricator.
K. Site VisitPrior to installation of the signs, the Fabricator is to visit the proposed sites to observe existing conditions and verify all signage required and its location with UNO. At this time the locations shall be staked using a non-permanent visible device such as spray chalk or non-permanent paint. Certain signs may be located on sloped grades and may require uneven footings for each post. Site-verify all locations to determine special requirements for footing templates, if required.
The final Sign Message Schedule and Sign Location Plan shall be consulted together and shall be approved by SCSU to determine the precise location for each sign. Any neces-sary adjustments will be made with the approval of SCSU.
L. Masonry/FootingsAny concrete bases for signage are to be poured in place and footings are to extend beneath the frost line, or deeper to meet local code. All footings or bases should be poured within a form and level with grade unless otherwise specified in the design intent drawings. Foundation/footings should be level with grade unless otherwise noted or as specified by state or local code. Foundation/footings should not extend above grade more than 2" and exposed edges should be finished with a bevel to prevent chipping. It’s recommended that the concrete be floated by machine or hand before finishing in order to embed larger aggregates especially when part of the footing or base extends above ground. Concrete surface should have a smooth or brushed
finish grade appearance. All concrete bases and footings should be edged to break any bond with the form and create a neat appearance. All forms should be removed once the concrete has properly cured. Concrete and reinforcement specifications shall be shown on shop drawing submittals. The Fabricator is responsible for the necessary templates, mounting plates and hardware for concrete and masonry bases. A minimum 1’ rock bed with landscape edging or concrete pad must be added around each concrete base as protection from landscaping mainte-nance. All masonry (concrete block, poured concrete, brick, slab, veneer, mortar, etc.) is to be properly treated and protected to maintain the structural integrity of the masonry work with exposure to all environmental conditions found at the site. For exposed or visible masonry, this shall include the application of protective sealers or similar finishes to diminish the effects of close-proximity sprinkling or irriga-tion systems.
Signs are to be mounted on J-bolt footings, centered on the concrete base or footing, and engineered per code, unless otherwise specified in the design intent drawings.
M. Wind LoadSigns, banners and mounting devices shall be engineered to withstand a minimum 30-psf wind load normal to the sign, or greater as per local code, in addition to the weight of the sign. The Fabricator shall determine appropriate method of anchoring signs to the locations specified to meet these requirements as well as all local code requirements.
N. MountingAll signs are to be mounted level and true. All exposed hardware is to be touch-up painted on site as required. It is preferred that all bolts, nuts, washers, or other fasteners be stainless steel. However galvanized steel is acceptable, so long as all exposed surfaces are sealed.
While sign type drawings may specify or indicate possible mounting and/or mounting hardware details, the Fabricator will be able to substitute equal or better hardware and techniques, based upon their experience with similar mounting situations and as long as the visual appearance of the sign is not compromised from that shown in the design intent drawings.
All signage products must be installed such that there are no misalignments between visible components. Sign elements intended to be removable or changeable after installation must function as intended without binding, sticking or blocking. It will be the responsibility of the Fabricator to correct any installation misalignments at no charge.Fabricator and their installers are expected to have knowl-
edge of ADA mounting guidelines and city zoning codes, general sign locating practices, and any particular unique installations defined by SCSU. It is the desire of SCSU that the Fabricator follow these guidelines as well as architectural cues in installing for the best visual placement, keeping a reasonable distance from protruding objects. Any signage that is improperly located is to be moved to the proper location by the Fabricator, and repairs to wall surfaces and signage are to be completed at the Fabricator’s expense.
If the installers are unable to make a decision about any sign locations, they must contact SCSU, providing a graphic representation of the questionable area, or for on-site options.
O. ElectricalSCSU will be responsible for providing a power source to within 10 feet of the base of each sign requiring power (either at grade or below grade). Power is to be 120 or 277 (LED illumination should be 120) volts at 60 cycles unless otherwise noted in the documents. It is the responsibility of the Fabricator to manipulate the existing conduit to its proper location, install an external disconnect, extend the conduit through the concrete base (or posts) to align with the point of hookup, and run the power supply through it. Conduit running from the disconnect to the sign shall travel within the concrete base, not on its surface. The Fabricator will be responsible for the final electrical connection.
P. PunchlistIt is required that the successful Bidder complete a walk through with SCSU immediately following installation to identify any errors, such as construction or installation issues. Such errors are to be corrected in a timely manner, and to the satisfaction of SCSU.
Q. Site Safety and RestorationDuring the installation period, successful Bidders and subcontractors are responsible for their own safety, and are expected to maintain a safe environment for pedestrians. Successful Bidders and subcontractors are to keep SCSU’s premises and the adjoining premises, driveways and streets clean and clear. Job site shall be left safe, neat and clean at the completion of each day’s operation. Successful Bidders and subcontractors are also expected to temporarily maintain old signs in order to continue their directional and identification functions, as well as to maintain signage that meets MUTCD standards during the installation period. At the completion of work, successful Bidder and subcontrac-tors shall remove all rubbish, tools, equipment, and surplus materials, from and about the premises, and shall leave the site as originally found. Successful Bidder shall be responsi-ble for repairing or correcting damage to other contractors’ work resulting from successful Bidder’s work.R. Signage Warranty
FABRICATION SPECIFICATIONS: EXTERIOR SIGNAGE
The successful Bidder is to provide a written five (5) year full replacement warranty to SCSU that all signs will be free of defects due to craft work including, but not limited to:
1. Bubbling, chalking, rusting or other disintegration of the sign panel, graphics or of the edges.
2. Corrosion appearing beneath paint and vinyl surfaces, on sign panels, brackets, posts or other support assemblies (except as an obvious result of vandalism or other external damage).
3. Corrosion of fasteners.
4. The assemblies not remaining true and plumb on their supports.
5. Peeling, delamination or warping (“oil canning”).
6. Repair and reinstallation of signage due to failed mountings.
Successful Bidder shall also extend in writing to SCSU all manufacturers’ warranties for materials and components used within the signs. It is the Successful Bidder’s responsibili-ty to obtain extended 5-year manufacturer warranties on all paint and powder coat applications.
S. Repair or ReplacementWithout additional cost to SCSU, the successful Bidder shall repair or replace, including installation, any defective signs or hardware which develop during the warranty period and repair any damage to other work due to such imperfections. The successful Bidder will be required to fully replace all signs that are in error relative to the working documents (sign message schedule and sign type drawings) that will be submitted to the successful Bidder upon award of contract.
T. Pre-fabrication Submittals Upon award of contract, the successful Bidder must submit a copy of the following items to SCSU for their review prior to fabrication of the prototypes and rest of the fabrication package:
1. Detailed engineered shop drawings for each sign type are to be submitted as electronic PDF no larger than 11”x 17”. Final Shop Drawings are to be stamped by an Engineer licensed in the State of Minnesota. The shop drawings for each sign type shall illustrate/describe the following:
i. Elevations and cross sections – front, sides, top and back (if necessary); side sections; internal structure section/details; enlarged details such as of extrusions, push-through letter mounting, mounting plate, etc.; with all final dimensions and call-outs for:
• Components – construction details/information related to individual elements
• Materials – color, type, gauge, and thickness (including substrates and overlays)
• Finishes – color, type of product, manufacturer, and sheen
• Fonts, graphics specifications and message fields
ii. Exploded view (optional) – isometric view with compo-nents, materials, and finishes.
iii. Cross-section of corners – one illustration for each corner condition. Items to be illustrated: seams, joints, layers, internal support and fasteners.
iv. Mounting/installation details – provide foundation cross-sections (including hardware), bracket/post details, elevations, materials, finishes and fasteners.
v. Electrical details are to be provided for all elements that require electricity. Specific items to be listed are:
• Light source and/or fixture type and manufacturer
• Power supply (transformer)
• Amperage and voltage per sign
• Electrical service required (source)
• Lighting detail – provide an internal view of light fixtures, LED layout, transformers, external cut-off switch, light sensor, and timer.
vi. Engineering for wind load
vii. Removable panels (where applicable)
viii. Identify any dimensional or other changes in the overall sign required by virtue of the fabrication materi-als, techniques and/or engineering.
2. Two (2) samples of each material (paint, vinyl, acrylic, veneer, masonry, metal, etc.) to be used on the sign using actual substrate materials. One sample will be returned, one kept by SCSU.
3. A proofing document of final production keystroking for all sign messages to verify line breaks, character and word spacing, and interline spacing. The proofs are to be scaled production art files, not full sized. Each layout is to be identified with the sign number.
U. Electronic Message Board TrainingThe awarded sign fabricator is responsible for providing training for the owner on how to properly use the software and hardware for electronic message board. Fabricator will also accept and answer questions from the owner anout the function of the electronic message board for up to 3 months after initial training.
7
A. Quality StandardsThe materials, products, equipment and performance specifications described within establish a standard of required function, dimension, appearance, performance and quality to be met by the Fabricator. B. Structural DesignDetails on design intent drawings indicate a design approach for sign structure but do not necessarily include all fabrication details required for the complete structural integrity of the signs, including consideration for static, dynamic and erection loads during handling, erecting, and service at the installed locations, nor do they necessarily consider the preferred shop practices of the individual Fabricators. Therefore, it shall be the responsibility of the Fabricator to perform the complete structural design and engineering of the signs and to incorporate all the safety features necessary to adequately support the sign for its intended use and purpose and to protect UNO. Fabricator shall also be responsible for ensuring that all signs meet local, state and federal codes.
C. Vandalism DesignFabrication and installation design is to withstand severe abuse and souvenir theft vandalism, but not less than the equivalent of resisting simple hand implements and tools (screwdrivers, knives, coins, keys, and similar items), and adult physical force. All hardware and fasteners within reach shall be vandal resistant.
D. SubstitutionNo substitution will be considered unless UNO has received written request for approval. Fabricator may recommend equal or better equipment or method, but will be required to provide full documentation establishing such a substitution’s equality or superiority as measured in the following:
• compliance with the visual design intent;
• cost;
• ease of maintenance; and
• performance.
The burden of proof of the merit of the proposed substitute is upon the Fabricator. UNOs decision of approval or disapproval of a proposed substitution shall be final.
E. Material HandlingThe Fabricator is to pack, wrap, crate, bundle, box, bag, or otherwise package, handle, transport, and store all fabri-cated work as necessary to provide protection from damage by every cause. Fabricator shall provide clear and legible identifying information on all product packaging to ensure proper on-site identification and installation.
F. Sign Specifications: Construction MethodologyThe drawings call for a variety of fabrication techniques. Fabricators are given leeway to fabricate the signs to meet the intent of the designs depicted by the drawings.
1. Because different systems of extrusions may result in slightly different dimensional requirements, the total height and width dimensions described in the signconstruction on the drawings may be considered “nominal” for the purposes of cost quote.
2. Sign faces are to be fabricated using aluminum plate of varying thicknesses, as specified on design intent drawings, with a minimum thickness of .125" unless otherwise noted.
3. Unless otherwise noted on the design intent drawings, all cut-out push-through copy is to be routed from a single sheet of white acrylic, with a minimum thickness of 3/8" and pushed through 1/16". Routed letters and shapes that are bonded to a separate acrylic sheet are not acceptable; they must be routed from a single sheet.
• Acrylic is to be attached to the back of the sign using adhesive, mechanical fasteners, or both depending on the design specifications.
• All letter knock-outs (interior of letter forms) are to be stud mounted through the acrylic.
• When illuminating the acrylic face with Fluorescent or Neon, 7328 shall be the standard white acrylic.
• When illuminating the acrylic face with LED, 2447 shall be the standard white acrylic.
• Acceptable spacing between the push-through acrylic and the cut-out aluminum is 1/32" to 1/16" depending on the copy height (if the copy is larger than 32", alternate spacing may be used to allow for the change in material expansion).
4. Sign cabinet seams shall be sealed to ensure they are watertight.
5. All finishes are to be satin finish, free from fading, peeling or cracking. Paint preparation of all exterior metal surfaces of the sign to include removal of all scratches and imperfections, sanding and chemical etching. Substrate cleaning, preparation, paint application and paint thick-ness to be in strict compliance with Matthews Paint or AkzoNobel published recommendations. Acceleration of the drying process is not allowed. Clear final top coat is required
6. Except where approved otherwise by UNO, conceal fasteners.
7. Any sign faces smaller than 8’ by 20’ are to be fabri-cated from 1 piece of seamless material.
8. On welded joints, dimensional and structural welding defects will not be accepted, including but not limited to: poor weld contours, including excessive bead convexity and reinforcement, and considerable concavity or under-sized welds; cracks; undercutting; porosity; incomplete fusion; inadequate penetration; spatter; and non-metallic inclusions. Welding is to be performed by AWS (or similar) certified personnel, following AWS Standard Welding Procedure Specifications (SWPSs) for steel, aluminum, and stainless steel as appropriate.
9. Non-welded joints between various portions of signs must have a tight, hairline-type appearance, without gaps. Provide sufficient fastenings to preclude looseness, racking, or similar movement.
10. Provide drain holes as needed to prevent accumula-tion of water within signs. Holes must be inconspicuous and be in inconspicuous locations; holes must be located such that drainage does not occur onto signs, or other surfaces subject to staining. Provide internal system of baffles to prevent “light leaks” through drain holes of illuminated signs. Provide color-coordinated insect screening over drain holes.
11. Non-illuminated sign faces are to have lettering and graphics created as silk-screening or as surface-applied vinyl typography using Oracal exterior grade, minimum 5-year warranty, as noted in the design intent drawings.
12. Visible metal joints must adhere to a fit tolerance of .01".
13. Unlit channel letter faces must be .25" aluminum. Channel letter returns must be .080" aluminum.
G. Sign Specifications: Illumination & ElectricalIt shall be the responsibility of the Fabricator to perform the complete electrical design for illuminated signs. Illuminated signs shall be designed by an electrical engineer and shall be fabricated and wired to be compliant with current UL listing requirements, and shall be UL certified.
1. All internally illuminated sign cabinets are to have an access panel that is tight fitting, lightproof and water-proof. Access panels are to be in an accessible location, out of sight, and shall be shown on shop drawings.
2. Internally illuminated signs are to have an adequate internal system of ventilation to assure a uniform dissipa-tion of heat from electrical components of electrically powered and illuminated signs, heat (solar) absorption by sign and other sources. Any openings in exterior surfaces
must be internally baffled to prevent light leaks and prevent entry of rain, snow, wind-blown debris, and other foreign matter, and are to be covered with interior color-coordinated insect screen.
3. Only labels required by law are permitted to be mounted on the exterior of the sign face, and they shall be located in a position that is as discreet as possible.
4. All internally illuminated interior metal surfaces shall be painted white using Matthews’ reflective white paint, or shall be lined with 3M’s Matte White Light Enhance-ment Film, to enhance and evenly distribute light.
5. All electrical components shall be built to be housed within sign cabinets. All wiring and raceways within the sign are to be completely enclosed. Internal illumination by LED is required to provide adequate and even illumina-tion over the face of the sign without hot spots or shadows. “Halo” effects, “spreading” or similar light spill due to excessive transmission of the backlight source shall be minimized.
6. Illumination to be provided by LED as specified on design intent drawings. Internal hardware must not be visible through the translucent letterforms and graphics.
7. All internally illuminated exterior signs are to have their own electric eye on/off control to turn the sign on at night and off in the morning, unless UNO specifies a need for a timer. Location of eye to be shown on shop draw-ings.
8. Verify location of power provided by others prior to sign fabrication.
9. Face-lit channel letters with a 16" or shorter cap height shall be trimless. Face-lit channel letters taller than 16" may use a low-profile trim cap. Internally illuminated channel letters shall be illuminated using LED, unless otherwise noted on the design intent drawings. Trans-formers for channel letters shall be remote transformers wherever possible. If remote transformers are not appli-cable, then all electrical components shall be contained within the channel letter itself. Raceways are not accept-able unless specifically noted on the design intent drawing or if approved by UNO. All raceways must be painted the same color as the wall on which the sign will be mounted. Channel letters to be painted on the inside with Matthews’ reflective white paint, or lined with 3M’s Matte White Light Enhancement Film to enhance and evenly distribute light.
I. Fonts/TypefacesThe fonts used for this project were selected specifically for this project by UNO, and include those listed in the graphic standards. It is the responsibility of the fabricator to purchase the fonts.
No substitution of any other typefaces may be made. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composi-tion unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
1. All letterforms, symbols or graphics shall be repro-duced either by photographic or computer-generated means. Hand-cut characters are not acceptable. Cutting shall be done in such manner that edges and corners of finished letterforms will be sharp and true. Letterforms with nicked, cut, ragged, rounded corners, and similar disfigurements will not be acceptable.
2. All letterforms shall be made from material and gauge as indicated on design intent drawings. Typefaces shall be replicated as indicated on the drawing.
3. Ligatures are to be turned off.
4. Apostrophes are to be used, not footmarks. Note that there is a difference in most fonts.
5. Silk-screened and vinyl copy is to match the sheen of the copy panel background (satin). Edges of letters shall be straight and corners sharp. Surface of letters shall be uniform in color finish, and free from pinholes and other imperfections.
6. Silk-screened images shall be executed with photo screens prepared from original art. No hand-cut screens will be accepted. Original art shall be defined as artwork that is a first generation reproduction of the specified art.
7. Silk-screening shall be highest quality, with sharp lines and no sawtooths or uneven ink coverage. Screens shall be photographically produced. Application of inks through screens shall consist of one flood pass and one print pass. Images shall be uniform in color and ink thickness. Images shall be free from squeegee marks and lines resulting from improper print stroke or screen off contact height. Signs shall be placed in adequate drying racks with minimum of 2 inches between racks for ample airflow. Sign racks shall have system of forced airflow between layers to provide proper drying and curing of inks. After signs have dried completely according to the ink manufacturer’s time allowance, signs may be packaged.
8. The edges and corners of routed letterforms shall be sharp and true. Letterforms with nicked, cut, ragged, rounded (positive or negative) corners, and similar disfigurements will not be acceptable.
9. Letterforms shall be aligned so as to maintain a base line parallel to the sign format, with margins and layout as indicated on design intent drawings and approved shop drawings. Vertical strokes shall be plumb.
10. Vinyl graphics and letterforms shall be computer-cut.
J. Permits and VariancesFabricator shall be knowledgeable of relevant local code requirements and honor same in fabrication and installa-tion. Where applicable, it is the responsibility of the Fabrica-tor to secure any and all necessary permits for signage installation. It is the responsibility of UNO to secure variances, should any be required. It is UNO ’s responsibility to call the appropriate agency to have all underground utilities properly located and marked. Any damage to below-grade utilities or structures for which UNO has provided adequate location information is the responsibility of the Fabricator.
K. Site VisitPrior to installation of the signs, the Fabricator is to visit the proposed sites to observe existing conditions and verify all signage required and its location with UNO. At this time the locations shall be staked using a non-permanent visible device such as spray chalk or non-permanent paint. Certain signs may be located on sloped grades and may require uneven footings for each post. Site-verify all locations to determine special requirements for footing templates, if required.
The final Sign Message Schedule and Sign Location Plan shall be consulted together and shall be approved by UNO to determine the precise location for each sign. Any neces-sary adjustments will be made with the approval of UNO.
L. Masonry/FootingsAny concrete bases for signage are to be poured in place and footings are to extend beneath the frost line, or deeper to meet local code. All footings or bases should be poured within a form and level with grade unless otherwise specified in the design intent drawings. Foundation/footings should be level with grade unless otherwise noted or as specified by state or local code. Foundation/footings should not extend above grade more than 2" and exposed edges should be finished with a bevel to prevent chipping. It’s recommended that the concrete be floated by machine or hand before finishing in order to embed larger aggregates especially when part of the footing or base extends above
ground. Concrete surface should have a smooth or brushed finish grade appearance. All concrete bases and footings should be edged to break any bond with the form and create a neat appearance. All forms should be removed once the concrete has properly cured. Concrete and reinforcement specifications shall be shown on shop drawing submittals. The Fabricator is responsible for the necessary templates, mounting plates and hardware for concrete and masonry bases. A minimum 1’ rock bed with landscape edging or concrete pad must be added around each concrete base as protection from landscaping mainte-nance. All masonry (concrete block, poured concrete, brick, slab, veneer, mortar, etc.) is to be properly treated and protected to maintain the structural integrity of the masonry work with exposure to all environmental conditions found at the site. For exposed or visible masonry, this shall include the application of protective sealers or similar finishes to diminish the effects of close-proximity sprinkling or irriga-tion systems.
Signs are to be mounted on J-bolt footings, centered on the concrete base or footing, and engineered per code, unless otherwise specified in the design intent drawings.
M. Wind LoadSigns, banners and mounting devices shall be engineered to withstand a minimum 30-psf wind load normal to the sign, or greater as per local code, in addition to the weight of the sign. The Fabricator shall determine appropriate method of anchoring signs to the locations specified to meet these requirements as well as all local code requirements.
N. MountingAll signs are to be mounted level and true. All exposed hardware is to be touch-up painted on site as required. It is preferred that all bolts, nuts, washers, or other fasteners be stainless steel. However galvanized steel is acceptable, so long as all exposed surfaces are sealed.
While sign type drawings may specify or indicate possible mounting and/or mounting hardware details, the Fabricator will be able to substitute equal or better hardware and techniques, based upon their experience with similar mounting situations and as long as the visual appearance of the sign is not compromised from that shown in the design intent drawings.
All signage products must be installed such that there are no misalignments between visible components. Sign elements intended to be removable or changeable after installation must function as intended without binding, sticking or blocking. It will be the responsibility of the Fabricator to correct any installation misalignments at no charge.
Fabricator and their installers are expected to have knowl-edge of ADA mounting guidelines and city zoning codes, general sign locating practices, and any particular unique installations defined by UNO. It is the desire of UNO that the Fabricator follow these guidelines as well as architectural cues in installing for the best visual placement, keeping a reasonable distance from protruding objects. Any signage that is improperly located is to be moved to the proper location by the Fabricator, and repairs to wall surfaces and signage are to be completed at the Fabricator’s expense.
If the installers are unable to make a decision about any sign locations, they can contact UNO, providing a graphic representation of the questionable area, or for on-site options.
O. ElectricalUNO will be responsible for providing a power source to within 10 feet of the base of each sign requiring power (either at grade or below grade). Power is to be 120 or 277 (LED illumination should be 120) volts at 60 cycles unless otherwise noted in the documents. It is the responsibility of the Fabricator to manipulate the existing conduit to its proper location, install an external disconnect, extend the conduit through the concrete base (or posts) to align with the point of hookup, and run the power supply through it. Conduit running from the disconnect to the sign shall travel within the concrete base, not on its surface. The Fabricator will be responsible for the final electrical connection.
P. PunchlistIt is required that the successful Bidder complete a walk through with UNO immediately following installation to identify any errors, such as construction or installation issues. Such errors are to be corrected in a timely manner, and to the satisfaction of UNO.
Q. Site Safety and RestorationDuring the installation period, successful Bidders and subcontractors are responsible for their own safety, and are expected to maintain a safe environment for pedestrians. Successful Bidders and subcontractors are to keep UNO’s premises and the adjoining premises, driveways and streets clean and clear. Job site shall be left safe, neat and clean at the completion of each day’s operation. Successful Bidders and subcontractors are also expected to temporarily maintain old signs in order to continue their directional and identification functions, as well as to maintain signage that meets MUTCD standards during the installation period. At the completion of work, successful Bidder and subcontrac-tors shall remove all rubbish, tools, equipment, and surplus materials, from and about the premises, and shall leave the site as originally found. Successful Bidder shall be respon-sible for repairing or correcting damage to other contrac-tors’ work resulting from successful Bidder’s work.
FABRICATION SPECIFICATIONS: EXTERIOR SIGNAGE
R. Signage WarrantyThe successful Bidder is to provide a written five (5) year full replacement warranty to UNO that all signs will be free of defects due to craft work including, but not limited to:
1. Bubbling, chalking, rusting or other disintegration of the sign panel, graphics or of the edges.
2. Corrosion appearing beneath paint and vinyl surfaces, on sign panels, brackets, posts or other support assemblies (except as an obvious result of vandalism or other external damage).
3. Corrosion of fasteners.
4. The assemblies not remaining true and plumb on their supports.
5. Peeling, delamination or warping (“oil canning”).
6. Repair and reinstallation of signage due to failed mountings.
Successful Bidder shall also extend in writing to UNO all manufacturers’ warranties for materials and components used within the signs. It is the Successful Bidder’s responsibil-ity to obtain extended 5-year manufacturer warranties on all paint and powder coat applications.
S. Repair or ReplacementWithout additional cost to UNO, the successful Bidder shall repair or replace, including installation, any defective signs or hardware which develop during the warranty period and repair any damage to other work due to such imperfections. The successful Bidder will be required to fully replace all signs that are in error relative to the working documents (sign message schedule and sign type drawings) that will be submitted to the successful Bidder upon award of contract.
T. Pre-fabrication Submittals Upon award of contract, the successful Bidder must submit a copy of the following items to UNO for their review prior to fabrication of the prototypes and rest of the fabrication package:
1. Detailed engineered shop drawings for each sign type are to be submitted as electronic PDF no larger than 11”x 17”. Final Shop Drawings are to be stamped by an Engineer licensed in the State of Nebraska. The shop drawings for each sign type shall illustrate/describe the following:
i. Elevations and cross sections – front, sides, top and back (if necessary); side sections; internal structure section/details; enlarged details such as of extrusions, push-through letter mounting, mounting plate, etc.; with all final dimensions and call-outs for:
• Components – construction details/information related to individual elements
• Materials – color, type, gauge, and thickness (including substrates and overlays)
• Finishes – color, type of product, manufacturer, and sheen
• Fonts, graphics specifications and message fields
ii. Exploded view (optional) – isometric view with compo-nents, materials, and finishes.
iii. Cross-section of corners – one illustration for each corner condition. Items to be illustrated: seams, joints, layers, internal support and fasteners.
iv. Mounting/installation details – provide foundation cross-sections (including hardware), bracket/post details, elevations, materials, finishes and fasteners.
v. Electrical details are to be provided for all elements that require electricity. Specific items to be listed are:
• Light source and/or fixture type and manufacturer
• Power supply (transformer)
• Amperage and voltage per sign
• Electrical service required (source)
• Lighting detail – provide an internal view of light fixtures, LED layout, transformers, external cut-off switch, light sensor, and timer.
vi. Engineering for wind load
vii. Removable panels (where applicable)
viii. Identify any dimensional or other changes in the overall sign required by virtue of the fabrication materi-als, techniques and/or engineering.
2. Two (2) samples of each material (paint, vinyl, acrylic, veneer, masonry, metal, etc.) to be used on the sign using actual substrate materials. One sample will be returned, one sent to UNO.
3. A proofing document of final production keystroking for all sign messages to verify line breaks, character and word spacing, and interline spacing. The proofs are to be scaled production art files, not full sized. Each layout is to be identified with the sign number.
8
A. Quality StandardsThe materials, products, equipment and performance specifications described within establish a standard of required function, dimension, appearance, performance and quality to be met by the Fabricator. B. Structural DesignDetails on design intent drawings indicate a design approach for sign structure but do not necessarily include all fabrication details required for the complete structural integrity of the signs, including consideration for static, dynamic and erection loads during handling, erecting, and service at the installed locations, nor do they necessarily consider the preferred shop practices of the individual Fabricators. Therefore, it shall be the responsibility of the Fabricator to perform the complete structural design and engineering of the signs and to incorporate all the safety features necessary to adequately support the sign for its intended use and purpose and to protect UNO. Fabricator shall also be responsible for ensuring that all signs meet local, state and federal codes.
C. Vandalism DesignFabrication and installation design is to withstand severe abuse and souvenir theft vandalism, but not less than the equivalent of resisting simple hand implements and tools (screwdrivers, knives, coins, keys, and similar items), and adult physical force. All hardware and fasteners within reach shall be vandal resistant.
D. SubstitutionNo substitution will be considered unless UNO has received written request for approval. Fabricator may recommend equal or better equipment or method, but will be required to provide full documentation establishing such a substitution’s equality or superiority as measured in the following:
• compliance with the visual design intent;
• cost;
• ease of maintenance; and
• performance.
The burden of proof of the merit of the proposed substitute is upon the Fabricator. UNOs decision of approval or disapproval of a proposed substitution shall be final.
E. Material HandlingThe Fabricator is to pack, wrap, crate, bundle, box, bag, or otherwise package, handle, transport, and store all fabri-cated work as necessary to provide protection from damage by every cause. Fabricator shall provide clear and legible identifying information on all product packaging to ensure proper on-site identification and installation.
F. Sign Specifications: Construction MethodologyThe drawings call for a variety of fabrication techniques. Fabricators are given leeway to fabricate the signs to meet the intent of the designs depicted by the drawings.
1. Because different systems of extrusions may result in slightly different dimensional requirements, the total height and width dimensions described in the signconstruction on the drawings may be considered “nominal” for the purposes of cost quote.
2. Sign faces are to be fabricated using aluminum plate of varying thicknesses, as specified on design intent drawings, with a minimum thickness of .125" unless otherwise noted.
3. Unless otherwise noted on the design intent drawings, all cut-out push-through copy is to be routed from a single sheet of white acrylic, with a minimum thickness of 3/8" and pushed through 1/16". Routed letters and shapes that are bonded to a separate acrylic sheet are not acceptable; they must be routed from a single sheet.
• Acrylic is to be attached to the back of the sign using adhesive, mechanical fasteners, or both depending on the design specifications.
• All letter knock-outs (interior of letter forms) are to be stud mounted through the acrylic.
• When illuminating the acrylic face with Fluorescent or Neon, 7328 shall be the standard white acrylic.
• When illuminating the acrylic face with LED, 2447 shall be the standard white acrylic.
• Acceptable spacing between the push-through acrylic and the cut-out aluminum is 1/32" to 1/16" depending on the copy height (if the copy is larger than 32", alternate spacing may be used to allow for the change in material expansion).
4. Sign cabinet seams shall be sealed to ensure they are watertight.
5. All finishes are to be satin finish, free from fading, peeling or cracking. Paint preparation of all exterior metal surfaces of the sign to include removal of all scratches and imperfections, sanding and chemical etching. Substrate cleaning, preparation, paint application and paint thick-ness to be in strict compliance with Matthews Paint or AkzoNobel published recommendations. Acceleration of the drying process is not allowed. Clear final top coat is required
6. Except where approved otherwise by UNO, conceal fasteners.
7. Any sign faces smaller than 8’ by 20’ are to be fabri-cated from 1 piece of seamless material.
8. On welded joints, dimensional and structural welding defects will not be accepted, including but not limited to: poor weld contours, including excessive bead convexity and reinforcement, and considerable concavity or under-sized welds; cracks; undercutting; porosity; incomplete fusion; inadequate penetration; spatter; and non-metallic inclusions. Welding is to be performed by AWS (or similar) certified personnel, following AWS Standard Welding Procedure Specifications (SWPSs) for steel, aluminum, and stainless steel as appropriate.
9. Non-welded joints between various portions of signs must have a tight, hairline-type appearance, without gaps. Provide sufficient fastenings to preclude looseness, racking, or similar movement.
10. Provide drain holes as needed to prevent accumula-tion of water within signs. Holes must be inconspicuous and be in inconspicuous locations; holes must be located such that drainage does not occur onto signs, or other surfaces subject to staining. Provide internal system of baffles to prevent “light leaks” through drain holes of illuminated signs. Provide color-coordinated insect screening over drain holes.
11. Non-illuminated sign faces are to have lettering and graphics created as silk-screening or as surface-applied vinyl typography using Oracal exterior grade, minimum 5-year warranty, as noted in the design intent drawings.
12. Visible metal joints must adhere to a fit tolerance of .01".
13. Unlit channel letter faces must be .25" aluminum. Channel letter returns must be .080" aluminum.
G. Sign Specifications: Illumination & ElectricalIt shall be the responsibility of the Fabricator to perform the complete electrical design for illuminated signs. Illuminated signs shall be designed by an electrical engineer and shall be fabricated and wired to be compliant with current UL listing requirements, and shall be UL certified.
1. All internally illuminated sign cabinets are to have an access panel that is tight fitting, lightproof and water-proof. Access panels are to be in an accessible location, out of sight, and shall be shown on shop drawings.
2. Internally illuminated signs are to have an adequate internal system of ventilation to assure a uniform dissipa-tion of heat from electrical components of electrically powered and illuminated signs, heat (solar) absorption by sign and other sources. Any openings in exterior surfaces
must be internally baffled to prevent light leaks and prevent entry of rain, snow, wind-blown debris, and other foreign matter, and are to be covered with interior color-coordinated insect screen.
3. Only labels required by law are permitted to be mounted on the exterior of the sign face, and they shall be located in a position that is as discreet as possible.
4. All internally illuminated interior metal surfaces shall be painted white using Matthews’ reflective white paint, or shall be lined with 3M’s Matte White Light Enhance-ment Film, to enhance and evenly distribute light.
5. All electrical components shall be built to be housed within sign cabinets. All wiring and raceways within the sign are to be completely enclosed. Internal illumination by LED is required to provide adequate and even illumina-tion over the face of the sign without hot spots or shadows. “Halo” effects, “spreading” or similar light spill due to excessive transmission of the backlight source shall be minimized.
6. Illumination to be provided by LED as specified on design intent drawings. Internal hardware must not be visible through the translucent letterforms and graphics.
7. All internally illuminated exterior signs are to have their own electric eye on/off control to turn the sign on at night and off in the morning, unless UNO specifies a need for a timer. Location of eye to be shown on shop draw-ings.
8. Verify location of power provided by others prior to sign fabrication.
9. Face-lit channel letters with a 16" or shorter cap height shall be trimless. Face-lit channel letters taller than 16" may use a low-profile trim cap. Internally illuminated channel letters shall be illuminated using LED, unless otherwise noted on the design intent drawings. Trans-formers for channel letters shall be remote transformers wherever possible. If remote transformers are not appli-cable, then all electrical components shall be contained within the channel letter itself. Raceways are not accept-able unless specifically noted on the design intent drawing or if approved by UNO. All raceways must be painted the same color as the wall on which the sign will be mounted. Channel letters to be painted on the inside with Matthews’ reflective white paint, or lined with 3M’s Matte White Light Enhancement Film to enhance and evenly distribute light.
I. Fonts/TypefacesThe fonts used for this project were selected specifically for this project by UNO, and include those listed in the graphic standards. It is the responsibility of the fabricator to purchase the fonts.
No substitution of any other typefaces may be made. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composi-tion unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
1. All letterforms, symbols or graphics shall be repro-duced either by photographic or computer-generated means. Hand-cut characters are not acceptable. Cutting shall be done in such manner that edges and corners of finished letterforms will be sharp and true. Letterforms with nicked, cut, ragged, rounded corners, and similar disfigurements will not be acceptable.
2. All letterforms shall be made from material and gauge as indicated on design intent drawings. Typefaces shall be replicated as indicated on the drawing.
3. Ligatures are to be turned off.
4. Apostrophes are to be used, not footmarks. Note that there is a difference in most fonts.
5. Silk-screened and vinyl copy is to match the sheen of the copy panel background (satin). Edges of letters shall be straight and corners sharp. Surface of letters shall be uniform in color finish, and free from pinholes and other imperfections.
6. Silk-screened images shall be executed with photo screens prepared from original art. No hand-cut screens will be accepted. Original art shall be defined as artwork that is a first generation reproduction of the specified art.
7. Silk-screening shall be highest quality, with sharp lines and no sawtooths or uneven ink coverage. Screens shall be photographically produced. Application of inks through screens shall consist of one flood pass and one print pass. Images shall be uniform in color and ink thickness. Images shall be free from squeegee marks and lines resulting from improper print stroke or screen off contact height. Signs shall be placed in adequate drying racks with minimum of 2 inches between racks for ample airflow. Sign racks shall have system of forced airflow between layers to provide proper drying and curing of inks. After signs have dried completely according to the ink manufacturer’s time allowance, signs may be packaged.
8. The edges and corners of routed letterforms shall be sharp and true. Letterforms with nicked, cut, ragged, rounded (positive or negative) corners, and similar disfigurements will not be acceptable.
9. Letterforms shall be aligned so as to maintain a base line parallel to the sign format, with margins and layout as indicated on design intent drawings and approved shop drawings. Vertical strokes shall be plumb.
10. Vinyl graphics and letterforms shall be computer-cut.
J. Permits and VariancesFabricator shall be knowledgeable of relevant local code requirements and honor same in fabrication and installa-tion. Where applicable, it is the responsibility of the Fabrica-tor to secure any and all necessary permits for signage installation. It is the responsibility of UNO to secure variances, should any be required. It is UNO ’s responsibility to call the appropriate agency to have all underground utilities properly located and marked. Any damage to below-grade utilities or structures for which UNO has provided adequate location information is the responsibility of the Fabricator.
K. Site VisitPrior to installation of the signs, the Fabricator is to visit the proposed sites to observe existing conditions and verify all signage required and its location with UNO. At this time the locations shall be staked using a non-permanent visible device such as spray chalk or non-permanent paint. Certain signs may be located on sloped grades and may require uneven footings for each post. Site-verify all locations to determine special requirements for footing templates, if required.
The final Sign Message Schedule and Sign Location Plan shall be consulted together and shall be approved by UNO to determine the precise location for each sign. Any neces-sary adjustments will be made with the approval of UNO.
L. Masonry/FootingsAny concrete bases for signage are to be poured in place and footings are to extend beneath the frost line, or deeper to meet local code. All footings or bases should be poured within a form and level with grade unless otherwise specified in the design intent drawings. Foundation/footings should be level with grade unless otherwise noted or as specified by state or local code. Foundation/footings should not extend above grade more than 2" and exposed edges should be finished with a bevel to prevent chipping. It’s recommended that the concrete be floated by machine or hand before finishing in order to embed larger aggregates especially when part of the footing or base extends above
ground. Concrete surface should have a smooth or brushed finish grade appearance. All concrete bases and footings should be edged to break any bond with the form and create a neat appearance. All forms should be removed once the concrete has properly cured. Concrete and reinforcement specifications shall be shown on shop drawing submittals. The Fabricator is responsible for the necessary templates, mounting plates and hardware for concrete and masonry bases. A minimum 1’ rock bed with landscape edging or concrete pad must be added around each concrete base as protection from landscaping mainte-nance. All masonry (concrete block, poured concrete, brick, slab, veneer, mortar, etc.) is to be properly treated and protected to maintain the structural integrity of the masonry work with exposure to all environmental conditions found at the site. For exposed or visible masonry, this shall include the application of protective sealers or similar finishes to diminish the effects of close-proximity sprinkling or irriga-tion systems.
Signs are to be mounted on J-bolt footings, centered on the concrete base or footing, and engineered per code, unless otherwise specified in the design intent drawings.
M. Wind LoadSigns, banners and mounting devices shall be engineered to withstand a minimum 30-psf wind load normal to the sign, or greater as per local code, in addition to the weight of the sign. The Fabricator shall determine appropriate method of anchoring signs to the locations specified to meet these requirements as well as all local code requirements.
N. MountingAll signs are to be mounted level and true. All exposed hardware is to be touch-up painted on site as required. It is preferred that all bolts, nuts, washers, or other fasteners be stainless steel. However galvanized steel is acceptable, so long as all exposed surfaces are sealed.
While sign type drawings may specify or indicate possible mounting and/or mounting hardware details, the Fabricator will be able to substitute equal or better hardware and techniques, based upon their experience with similar mounting situations and as long as the visual appearance of the sign is not compromised from that shown in the design intent drawings.
All signage products must be installed such that there are no misalignments between visible components. Sign elements intended to be removable or changeable after installation must function as intended without binding, sticking or blocking. It will be the responsibility of the Fabricator to correct any installation misalignments at no charge.
Fabricator and their installers are expected to have knowl-edge of ADA mounting guidelines and city zoning codes, general sign locating practices, and any particular unique installations defined by UNO. It is the desire of UNO that the Fabricator follow these guidelines as well as architectural cues in installing for the best visual placement, keeping a reasonable distance from protruding objects. Any signage that is improperly located is to be moved to the proper location by the Fabricator, and repairs to wall surfaces and signage are to be completed at the Fabricator’s expense.
If the installers are unable to make a decision about any sign locations, they can contact UNO, providing a graphic representation of the questionable area, or for on-site options.
O. ElectricalUNO will be responsible for providing a power source to within 10 feet of the base of each sign requiring power (either at grade or below grade). Power is to be 120 or 277 (LED illumination should be 120) volts at 60 cycles unless otherwise noted in the documents. It is the responsibility of the Fabricator to manipulate the existing conduit to its proper location, install an external disconnect, extend the conduit through the concrete base (or posts) to align with the point of hookup, and run the power supply through it. Conduit running from the disconnect to the sign shall travel within the concrete base, not on its surface. The Fabricator will be responsible for the final electrical connection.
P. PunchlistIt is required that the successful Bidder complete a walk through with UNO immediately following installation to identify any errors, such as construction or installation issues. Such errors are to be corrected in a timely manner, and to the satisfaction of UNO.
Q. Site Safety and RestorationDuring the installation period, successful Bidders and subcontractors are responsible for their own safety, and are expected to maintain a safe environment for pedestrians. Successful Bidders and subcontractors are to keep UNO’s premises and the adjoining premises, driveways and streets clean and clear. Job site shall be left safe, neat and clean at the completion of each day’s operation. Successful Bidders and subcontractors are also expected to temporarily maintain old signs in order to continue their directional and identification functions, as well as to maintain signage that meets MUTCD standards during the installation period. At the completion of work, successful Bidder and subcontrac-tors shall remove all rubbish, tools, equipment, and surplus materials, from and about the premises, and shall leave the site as originally found. Successful Bidder shall be respon-sible for repairing or correcting damage to other contrac-tors’ work resulting from successful Bidder’s work.
FABRICATION SPECIFICATIONS: EXTERIOR SIGNAGE
R. Signage WarrantyThe successful Bidder is to provide a written five (5) year full replacement warranty to UNO that all signs will be free of defects due to craft work including, but not limited to:
1. Bubbling, chalking, rusting or other disintegration of the sign panel, graphics or of the edges.
2. Corrosion appearing beneath paint and vinyl surfaces, on sign panels, brackets, posts or other support assemblies (except as an obvious result of vandalism or other external damage).
3. Corrosion of fasteners.
4. The assemblies not remaining true and plumb on their supports.
5. Peeling, delamination or warping (“oil canning”).
6. Repair and reinstallation of signage due to failed mountings.
Successful Bidder shall also extend in writing to UNO all manufacturers’ warranties for materials and components used within the signs. It is the Successful Bidder’s responsibil-ity to obtain extended 5-year manufacturer warranties on all paint and powder coat applications.
S. Repair or ReplacementWithout additional cost to UNO, the successful Bidder shall repair or replace, including installation, any defective signs or hardware which develop during the warranty period and repair any damage to other work due to such imperfections. The successful Bidder will be required to fully replace all signs that are in error relative to the working documents (sign message schedule and sign type drawings) that will be submitted to the successful Bidder upon award of contract.
T. Pre-fabrication Submittals Upon award of contract, the successful Bidder must submit a copy of the following items to UNO for their review prior to fabrication of the prototypes and rest of the fabrication package:
1. Detailed engineered shop drawings for each sign type are to be submitted as electronic PDF no larger than 11”x 17”. Final Shop Drawings are to be stamped by an Engineer licensed in the State of Nebraska. The shop drawings for each sign type shall illustrate/describe the following:
i. Elevations and cross sections – front, sides, top and back (if necessary); side sections; internal structure section/details; enlarged details such as of extrusions, push-through letter mounting, mounting plate, etc.; with all final dimensions and call-outs for:
• Components – construction details/information related to individual elements
• Materials – color, type, gauge, and thickness (including substrates and overlays)
• Finishes – color, type of product, manufacturer, and sheen
• Fonts, graphics specifications and message fields
ii. Exploded view (optional) – isometric view with compo-nents, materials, and finishes.
iii. Cross-section of corners – one illustration for each corner condition. Items to be illustrated: seams, joints, layers, internal support and fasteners.
iv. Mounting/installation details – provide foundation cross-sections (including hardware), bracket/post details, elevations, materials, finishes and fasteners.
v. Electrical details are to be provided for all elements that require electricity. Specific items to be listed are:
• Light source and/or fixture type and manufacturer
• Power supply (transformer)
• Amperage and voltage per sign
• Electrical service required (source)
• Lighting detail – provide an internal view of light fixtures, LED layout, transformers, external cut-off switch, light sensor, and timer.
vi. Engineering for wind load
vii. Removable panels (where applicable)
viii. Identify any dimensional or other changes in the overall sign required by virtue of the fabrication materi-als, techniques and/or engineering.
2. Two (2) samples of each material (paint, vinyl, acrylic, veneer, masonry, metal, etc.) to be used on the sign using actual substrate materials. One sample will be returned, one sent to UNO.
3. A proofing document of final production keystroking for all sign messages to verify line breaks, character and word spacing, and interline spacing. The proofs are to be scaled production art files, not full sized. Each layout is to be identified with the sign number.
9
04.28.15 Final Client Review
Graphic StandardsColor Palette, Typography,
Symbols and materials
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Fabricator is responsible for matching all colors and materials as specified and are required to provide the Owner color and material samples for approval.
CAUTION! CONSISTENT AND ACCURATE COLOR REPRODUCTION IN THIS DOCUMENT CANNOT BE ASSURED DUE TO THE LIMITATIONS OF COLOR COPYING TECHNOLOGY.
The Coated Pantone Matching System®, Akzo Nobel Paint system and Matthews Acrylic Polyurethatue are used for specifying signage color matches. (In the absence of actual sign material color chip reference sets, actual specified product color swatches should be referenced for color matching.)
Shown here are approximations of the primary signage background colors and supporting accent colors. Actual color finishes on signage must be matte or low luster (not shiny or glossy) and exclusively a premium acrylic polyurethane. Except for the high gloss anti-graffiti coating (Sikkens LV Anti Graffiti Clear).
Signage paints produced by Matthews Paint and Akzo Nobel Paint Company are to be the standard reference.
Vinyl Films from 3M, Oracal and Avery Graphics are to be the standard.
Color application varies per sign type. Refer to specific design intent drawings for application details.
124
MP00135
---
---
---
05 Yellow
Cool Gray 9
MP15661
---
---
---
439
MP42359
---
---
---
03 Medium Gray02 Dark Gray
202
MP08937
---
---
---
Pantone®:
Paint:
Oracal Series 5700 Reflective Vinyl:
Oracal Series 8500 Translucent Vinyl:
Oracal Series 751 Opaque Vinyl:
01 Red
Cool Gray 7
MP05295
---
---
---
04 Light Gray
White
MP27386
010 White
---
010 White
08 White
10 Water Pattern 11 Granite
Pantone®:
Paint:
Oracal Series 5700 Reflective Vinyl:
Oracal Series 8500 Translucent Vinyl:
Oracal Series 751 Opaque Vinyl:
485
MP00643
030 Red
032 Light Red
326 Signal Red
06 Caution Red
Black
MP00833
---
---
070 Black
07 Black
2925
MP00909
---
053 Light Blue
053 Light Blue
09 Parking Blue
Symbols Logos
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham XNarrow Light
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham XNarrow Book
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham XNarrow Medium
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham Book
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm Nn Oo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz 1234567890Gotham Medium
Standard Arrow Parking P[P]
No Entry[NE]
Typography
Color Palette Materials Palette
Barrier Free[BF]
No Parking[NP]
No Smoking[NS]
Material/Process: Material:Coldspring17482 Granite WestRoad, Coldspring, MNcoldspringusa.com
Cold Spring Black, Diamond 8
High Pressure Laminate
Direct Embed Powder Coatingwww.directembedcoating.com
10
DESIGN INTENT DRAWINGS
11
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-1Entrance Identifier/Guide
Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Top View
Side View
6th Street South
Atwood Memorial Center
Performing Arts Center
4th Ave S Pay Ramp
1/2" reveal painted Dark Gray.
Two-sided, LED internally illuminated aluminum sign fabricated from 1/8" (th.) material, SignComp™ components and internal structure as required.
Radiused cabinet01
Lower cabinet surface painted to match SCSU Red.01
Angled cabinet surface painted to match Medium Gray.03
Sign surface to have custom Wave Pattern. Suggested graphic processes:• High pressure laminate• Direct Embed Powder Coated Graphic
(www.directembedcoating.com)• Fabricator to suggest an alternate process
10
01
02
01
03
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
Electrical power supply provided to sign location by electrical contractor.
1'-3"
8'-11"
2 1/2"
10'-5"
8"
8"
8"
8"
2'-8 1/2"
5'-4 1/2"
9 1/2"
1'-2"
11"
10 1/2"
6"
9"
7'-5"
5'-6 1/2" 5"
R 9"
9"3'-0 1/2"
3'-4 1/2"
4'-1 1/2"
6"
1'-5"
Lower portion of cabinet fabricated using SignComp™ flush insert panel system for changeable faces and messaging. Suggested parts: Insert Retainer (#1666), Insert End Cover (#1696), Access Frame (#1690), and Insert Divider (#1668).
Upper portion of cabinet fabricated using SignComp™ medium body with tension frame and bleed tension frame cover. Suggested parts: Medium Body (#2015), Tension Frame (#2085) and Bleed Tension Frame Cover (#2095).
SignComp™ individual aluminum insert panels (part #1678) painted to match SCSU Red or Dark Gray. Messaging to be push-through white acrylic centered horizontally and vertically on panel. Fonts: Gotham XNarrow Book and Medium, 3 3/4" cap.
01
07
08
21 1/2" (size based on height) surface applied vinyl logo centered horizontall and vertically in upper cabinet. Black vinyl to be opaque and Dark Red vinyl to be translucent. Flex face background to match White.
1'-2"
6'-8 1/2"
21°
66°
82°
88°
106°
106°
11 Granite veneer foundation with one-piece faces. Butt joint external corners with the seams being on the sides of the sign. Veneer is installed on CMU or poured in place concrete core. Installation per Marble Institute of America Vertical Surfaces standards. Fabricator to provide final engineering and design of veneer foundation and to be approved by St. Cloud State University and Corbin Design.
12
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-1aLarge Boundary Marker
Non-Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Top View
Side View
1/2" reveal painted Dark Gray.
Two-sided, sign cabinet fabricated from 1/8" (th.) aluminum with internal structure as required.
01
Lower cabinet surface painted to match SCSU Red.01
Angled cabinet surface painted to match Medium Gray.03
03
01
03
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
1'-3"
8'-11"
10'-5"
4'-0"
10 1/2"
2"
5"
1'-8"
1'-5"
R 9"
9"3'-0 1/2"
3'-4 1/2"
4'-1 1/2"
6"
1'-5"
01
07
08
Masked and sprayed graphics with clear graffiti resistant top coat
4'-9"
9"center
21°
66°
82°
88°
106°
106°
11Granite veneer foundation with one-piece faces. Butt joint external corners with the
seams being on the sides of the sign. Veneer is installed on CMU or poured in place concrete
core. Installation per Marble Institute of America Vertical Surfaces standards. Fabricator
to provide final engineering and design of veneer foundation and to be approved by St.
Cloud State University and Corbin Design.
13
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-1bSmall Boundary Marker
Non-Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Top View
Side View
center
1/2" reveal painted Dark Gray.
Two-sided, non illuminated aluminum sign fabricated from 1/8" (th.) material, internal structure as required.
01
Lower cabinet surface painted to match SCSU Red.01
Angled cabinet surface painted to match Medium Gray.03
03
01
03
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
5'-10"
9 1/2"
6'-8"
2'-7"
6 1/2"
3'-0"
6"
1 1/2"
3"
1'-1"
11"
5"
1'-0"
01
07
08
Masked and sprayed graphics with clear graffiti resistant top coat
6"2'-0"
2'-3"
2'-8"
Two-sided, sign cabinet fabricated from 1/8" (th.) aluminum with internal structure as required.
21°
66°
82°
88°
106°
106°
11Granite veneer foundation with one-piece faces. Butt joint external corners with the
seams being on the sides of the sign. Veneer is installed on CMU or poured in place concrete
core. Installation per Marble Institute of America Vertical Surfaces standards. Fabricator
to provide final engineering and design of veneer foundation and to be approved by St.
Cloud State University and Corbin Design.
14
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-2Entrance Identifier/Guide
Illuminated
LED Message Board
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Top View
Side View
Athletic Complex
66°
82°
88°
106°
106°
1/2" reveal painted Dark Gray.
Two-sided, LED internally illuminated aluminum sign fabricated from 1/8" (th.) material, SignComp™ components and internal structure as required.
Radiused cabinet01
Lower cabinet surface painted to match SCSU Red.01
Angled cabinet surface painted to match Medium Gray.03
Sign surface to have custom Wave Pattern. Suggested graphic processes:• High pressure laminate• Direct Embed Powder Coated Graphic
(www.directembedcoating.com)• Fabricator to suggest an alternate process
10
01
02
01
03
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
Electrical power supply provided to sign location by electrical contractor.
1'-3"
9'-8"
11'-2"2'-10"
8"
2'-8 1/2"
6'-2"
9 1/2"
1'-2"
11"
10 1/2"
6"
9"
8'-2"
5'-6 1/2" 5"
R 9"
9"3'-0 1/2"
3'-4 1/2"
4'-1 1/2"
6"
1'-5"
Lower portion of cabinet fabricated using SignComp™ flush insert panel system for changeable faces and messaging. Suggested parts: Insert Retainer (#1666), Insert End Cover (#1696), Access Frame (#1690), and Insert Divider (#1668).
Upper portion of cabinet fabricated using SignComp™ medium body with tension frame and bleed tension frame cover. Suggested parts: Medium Body (#2015), Tension Frame (#2085) and Bleed Tension Frame Cover (#2095).
Double-sided SignComp™ aluminum cabinet. Messaging to be push-through white acrylic centered horizontally and vertically on panel. Font: Gotham XNarrow Book and Medium, 3 3/4" cap.
Double-sided Watchfire LED screens (Approximatley 2'-6" x 5'-0") 12mm pitch. Data connection to be determined.
01
07
08
21 1/2" (size based on height) surface applied vinyl logo centered horizontall and vertically in upper cabinet. Black vinyl to be opaque and SCSU Red vinyl to be translucent. Flex face background to match White.
1'-2"
6'-8 1/2"
LED screen vents
11 Granite veneer foundation with one-piece faces. Butt joint external corners with the seams being on the sides of the sign. Veneer is installed on CMU or poured in place concrete core. Installation per Marble Institute of America Vertical Surfaces standards. Fabricator to provide final engineering and design of veneer foundation and to be approved by St. Cloud State University and Corbin Design.
15
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-4Vehicular Roundabout Guide,
6in tall Copy
Non-Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Side ViewFront View
Alternate Layout
Top View
Back View
NorthCampus
NorthCampus
AthleticComplex
04
01
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
2'-8"
02
08
1/8" thick aluminum panel with high intensity white sheeting background and Oracal 073 Dark Grey transparent overlay
07
08
04
High intensity white sheeting background and Oracal 073 Dark Grey and 030 SCSU Red transparent overlay
1/8" thick aluminum panel with painted background
Welded end caps
04
01 3" x 3" square steel post painted to match SCSU Red
MNDOT approved breakaway base
center
7'-5"
1'-3"
4'-3"
7'-0"
4'-8"
11'-8"
2'-6"
1"
2'-8"
6"
9"6 1/2"
6"
3"
2 1/2"
01
16
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-5Primary Vehicular Guide Non-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front ViewPost Side View(from inside)
Top View
Visitor Parking
Atwood Memorial Ctr
Performing Arts Center
1'-8 1/2"
2"
1 1/2"
1 1/2"
2"
1'-6"
6 1/2"
6 1/2"
7 1/2"
7 1/2"
7 1/2"
6"
4"
7 1/2"
6"
4'-4 1/2"
5'-2"
7 1/2"
8"
7 1/2"
7 1/2"
7 1/2"
7 1/2"
2 1/2"
7 1/2"
7 1/2"
4'-7 1/2"
5'-6 1/2"
4'-0"
2 1/2"2 1/2"
5"
2 1/2"2 1/2"
5"
R 2 1/2"
5"1"5"
7'-2"
Two-sided, non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required. Paint to match Dark Gray and Light Gray.
1/8" (h.) rule lines to separate destinations painted to match Medium Gray.
1/2" reveals
02
03
03
5" dimensional post composed of three components: • 1/4" (th.) aluminum panel that supports the sign
cabinet painted to match Light Gray.• Custom radiused outside component painted to
match SCSU Red.• Angled inside component painted to match
SCSU Red.
Install sign by directly embedding posts in below grade concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04
01
01
08
09
5 1/4" (dia.) parking symbol with surface applied reflective white and parking blue vinyl.
08 Surface applied reflective vinyl messaging to match White. Left justify 2 3/4" from the edge of the sign cabinet and centered vertically between rule lines or color field. Font: Gotham XNarrow Book, 3 1/2" cap.
08 3 3/4" surface applied reflective vinyl arrow to match White centered vertically between rule lines or color field.
3'-8"
4'-6"
7'-4"
52°
52°
120°
45°
88°
17
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Gx-6Secondary Vehicular Guide Non-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Alternate Layout
Post Side View(from inside)
Top View
Engineering and Computer Center
Shoemaker Hall
52°
52°
120°
45°
88°
2nd Ave S Pay Lot
Atwood Memoral Ctr
1'-8 1/2"
2"
1 1/2"
1 1/2"
2"
1'-6"
6 1/2"
6 1/2"
7 1/2"
7 1/2"
7 1/2"
2 1/4"
3 1/2"
3 1/2"
3 1/2"
6"
2'-11"
3'-8 1/2"
7 1/2"
8"
7 1/2"
7 1/2"
7 1/2"
7 1/2"
3'-2"
4'-1"
4'-0"
2 1/2"
5"
2 1/2"2 1/2"
5"
R 2 1/2"
5"1"5"
5'-8 1/2"
Two-sided, non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required. Paint to match Dark Gray and Light Gray.
1/8" (h.) rule lines to separate destinations painted to match Medium Gray.
1/2" reveals
02
03
03
5" dimensional post composed of three components: • 1/4" (th.) aluminum panel that supports the sign
cabinet painted to match Light Gray.• Custom radiused outside component painted to
match SCSU Red.• Angled inside component painted to match
SCSU Red.
Install sign by directly embedding posts in below grade concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04
01
01
5 1/4" (dia.) parking symbol with surface applied reflective white and parking blue vinyl.
08 Surface applied reflective vinyl messaging to match White. Left justify 2 3/4" from the edge of the sign cabinet and centered vertically between rule lines or color field. Font: Gotham XNarrow Book, 3 1/2" cap.
08 3 3/4" surface applied reflective vinyl arrow to match White centered vertically between rule lines or color field.
3'-8"
4'-6"
5'-10 1/2"
1'-2"
88°
88°
08
09
5 1/4" (dia.) parking symbol with surface applied reflective white and parking blue vinyl.
08 5 1/4" (dia.) surface applied reflective white vinyl information symbol.
18
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-1aBuilding IdentificationFreestanding, OverheadNon-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
910 8th St S
Two MessageLines
CH
Front View Side ViewBack View
Alternate Layout
Top View
52°
52°
120°
10°910 8th St S
One Line
CH5 5/8"
6 3/4"
4"
2 3/4"
2'-5"
8 1/4"
6 3/4"
3"
2"
4"
2'-5"
2"
4"
2"
6'-2"
9"
Minimum 7'-0" clearanceto bottom of sign
2'-7 1/2"
4 3/4"
3'-9"
10'-1"
R 2 1/2"
5"1"
Two-sided, non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required.
1/2" reveals
02
5" dimensional post composed of three components: • 1/4" (th.) aluminum panel that supports the sign
cabinet painted to match Light Gray.• Custom radiused outside component painted to
match SCSU Red.• Angled inside component painted to match
SCSU Red.
Install sign by directly embedding posts in below grade concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04
01
01
08 Surface applied reflective vinyl messaging to match White. Font: Gotham XNarrow Medium
Surface applied reflective vinyl messaging to match White. Font: Gotham XNarrow Medium and Gotham XNarrow Light
08
2 1/2"
5"
3'-10 1/2"
3'-7 1/4"
Mask and spray color field. Font: Gotham XNarrow Medium
05
1'-2"
19
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix- 1bBuilding IdentificationFreestanding, LowNon-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
910 8th St S
Two MessageLines
CH
910 8th St S
One Line
CH
Front ViewBack View
Alternate Layout
Post Side View(from inside)
Top View
52°
52°
120°
45°
10°
910 8th St S
Two MessageLines
CH 3"
2"
1'-8 1/2"
2"
1 1/2"
2 5/8"
2"
4"
2"
1'-4"
7"
5 5/8"
6 3/4"
4"
2 3/4"
2'-5"
8 1/4"
6 3/4"
4"
2'-5"
3'-4"
9"
2'-7 1/2"
4 3/4"
3'-9"
4'-1"
R 2 1/2"
5"1"5"
5'-1"
Two-sided, non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required.
1/2" reveals
02
5" dimensional post composed of three components: • 1/4" (th.) aluminum panel that supports the sign
cabinet painted to match Light Gray.• Custom radiused outside component painted to
match SCSU Red.• Angled inside component painted to match
SCSU Red. Install sign by directly embedding posts in below grade concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04
01
01
08 Surface applied reflective vinyl messaging to match White. Font: Gotham XNarrow Medium
Surface applied reflective vinyl messaging to match White. Font: Gotham XNarrow Medium and Gotham XNarrow Light
08
2 1/2"
5"4'-1 1/2"
3'-7 1/4"
1/2"
Mask and spray color field. Font: Gotham XNarrow Medium
05
20
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-2Building ID – Wall-mounted, Large Non-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Top View
Front View
Garvey Commons
GC577 1st Ave S 3 3/4"
2" Non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required. Paint to match Dark Gray.
02
Angled aluminum end piece painted to match SCSU Red.
01
01
Mask and spray color field painted to match Yellow. Font: Gotham XNarrow Medium, 4 3/4" cap.
Fabricator to engineer attachment method using mechanical fasteners.
05
Radiused aluminum end piece painted to match SCSU Red.
01 08 Surface applied reflective vinyl messaging. Font: Gotham XNarrow Book and Medium, 4 3/4" cap.
2'-6"
1'-9"
1'-11"
8'-1"6 1/2" 6"
11 1/2"
6 1/2"
4 1/2"
2'-0 1/2"
Mount signto wall 72"from grade
(unless otherwisespecified)
6 1/2"4"
30°
22°
22°
22°
22°
10°
21
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-3Building ID – Wall-mounted, Small Non-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
910
ThreeMessageLines
CH22°22°
22°22°
Top View
Front View
Alternate Layouts Custom Layout
10°
1st Ave S
TwoMessage Lines
One Line
CH CH
Centennial HallBookstore
Herberger Business School
201 1st Ave S201 1st Ave S201 1st Ave S CH
1 3/4"
1"
Non-illuminated aluminum sign cabinet fabricated from 1/8" (th.) material and internal structure as required.
02
Angled aluminum end01
01
Mask and spray color field
Fabricator to engineer attachment method using mechanical fasteners.
05
Radiused aluminum end.01
08 Surface applied reflective vinyl messaging. Font: Gotham XNarrow Book and Medium
1'-8"
4 1/2"
1"2"
8"
center
maximumline length
8'-1"
2'-4"
2 1/4" 2 1/4"
2"
2"
1'-7"
2"
2"
1 1/4"
3 1/4"
1 3/4
1'-7"
2"
4 1/4"
2"
1 1/4"
1 3/4
1'-7"
2"
3"
2"
2"
1 1/2"
1 3/4
1'-7"
2"
5 3/4"
2"
1 3/4
Mount signto wall 72"from grade
(unless otherwisespecified)
3" 2"40°
22
04.28.15 Final Client Review
01 SCSU Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-5Parking Lot IdentificationNon-illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236Front View Side ViewBack View
Top View
120°
7'-0"
3'-8 5/8"
3"
11'-3"
5'-6"
R 2 1/2"
1/2"
4"
5"Approx 1/2"
Two-sided, non-illuminated aluminum sign panels.
1/2" reveal
02
5" dimensional post composed of three components: • 1/4" (th.) aluminum panel that supports the sign
cabinet painted to match Light Gray.• Custom radiused outside component painted to
match SCSU Red.• Angled inside component painted to match
SCSU Red.
Install sign by directly embedding posts in below grade concrete footing. Footing depth and reinforcement to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04
01
01
08
08
Surface applied reflective vinyl messaging
09
Surface applied reflective vinyl symbol
2 1/2"
5"1'-6"
2'-6"
1 1/2"
5"
4"
3 5/8"1"
3 3/4"
5 1/2"
1 3/4"
2"
3"
center
centersymbol
1'-0"
3'-7 1/2"
2'-5"
52°
52°
Minimum 7'-0" clearanceto bottom of sign
23
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-6Custom Parking Garage Identification(Retrofit existing sign cabinet)
Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
PUBLIC SAFETY CENTER4th Ave South Parking Ramp
Front View
Photo of existing sign
02
01
01
07
08
Refurbish existing double-sided internally illuminated cabinet. Refinish exisiting cabinet and replace message panels with cut-out and push-through white acrylic and translucent graphics.
appromimatley 13'-0"
fabricator tofield verify
2'-8"
centercenter
approximatley 2'-6"
1'-0"
4"
7"
4"
4"
3"2'-1"
1 3/8"
eq
eq
1'-4"
ALL SIZES APPROXIMATEFABRICATOR TO FIELD VERIFY SIZES
24
04.28.15 Final Client Review
01 SCSU Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
Not to scale
SCALE
Ix-7Pedestrian Bridge Branding
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
01
02
Painted both sides of concrete bridge. Use exterior grade concrete paint to match SCSU Red.
01
07
08
1/4"aluminum plate logo with painted finish. Flush stud mounted to concrete bridge. Logo to appear on both sides of bridge.
ALL SIZES APPROXIMATEFABRICATOR TO FIELD VERIFY SIZES
25
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Ix-8Campus Identification (retrofit)
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Photo of existing sign
Front View (logo symbol panel)
Plan View Plan View
Front View (logo type panel)
ALL SIZES APPROXIMATEFABRICATOR TO FIELD VERIFY SIZES
FABRICATOR TO FIELDVERIFY ANGLE
ALL SIZES APPROXIMATEFABRICATOR TO FIELD VERIFY SIZES
Pan-formed aluminum wall panel. Fabricated from 1/8" (th.) aluminum with 2" deep return edges.Mounted to wall with hidden mechanical fasteners.
01
08
03
01
07
08
Masked and sprayed graphics with clear graffiti
resistant top coat
Masked and sprayed graphics with clear graffiti resistant top coat
Existing concrete wall
5'-3"
5'-6 1/2"
1'-3"
2'-9"
center center
6'-7"
5'-3"
2'-1 1/4"
6"
2"2 1/2"
1'-0"
26
05.08.15 New Sign Type
01 SCSU Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
1/2" = 1'-0" (on a 11" x 17" paper)
SCALE
Dx-1Pedestrian Map Kiosk
Non-Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Top View
Side View Back View
Alternate Back Panels
OPTION 3Full Color Husky
OPTION 2Grey Husky
OPTION 1Water Pattern
Student CenterCentennial HallHeadley HallBrown Hall
21°
1/2" reveal painted Dark Gray.
Two-sided, non illuminated aluminum sign fabricated from 1/8" (th.) material, internal structure as required.
Lower cabinet surface painted to match SCSU Red.01
Changeable high pressure laminate panel
Changeable high pressure laminate panel to match background panel
02
01
02
01
02
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
Install sign by directly embedding posts in concrete footing. Footing depth and reinforcement to be engineered by fabricator.
6'-5"
9 1/2"
7'-5"
6 1/2"
4'-6"
1'-11"
9"
3'-0"
4"
3"
4 1/2"
1"1"
1 1/2"
3"
1'-1"
11"
5"
1'-0"
Changeable high pressure laminate graphic panel.
Final map artwork provided by others
Changeable high pressure laminate graphic panel.Three options for back panel:1. Water Pattern2. Grey Husky3. Full Color Husky
High Pressure Laminate Suppliers:
iZone Imaging 2526 Charter Oak Drive, Suite 100 Temple, TX 76502 USAToll Free 888.464.9663Local 254.778.0722Fax 254.778.0938Email: [email protected]
FOSSIL INDUSTRIES INC.44 Jefryn BoulevardDeer Park, NY 11729Phone: 631.254.9200Fax: 631.254.4172Email: [email protected]
Changeable high pressure laminate graphic panels
6"1'-5"
1 1/2"
1 1/4"
1'-8"
2'-2"
66°
82°
88°
106°106°
11
10
Atwood CenterPerforming Arts CenterLearning Resourse CenterAdministrative Services
Granite veneer foundation with one-piece faces. Butt joint external corners with the seams being on the sides of the sign. Veneer is installed on CMU or poured in place concrete core. Installation per Marble Institute of America Vertical Surfaces standards. Fabricator to provide final engineering and design of veneer foundation and to be approved by St. Cloud State University and Corbin Design.
27
04.28.15 Final Client Review
01 SCSU Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Dx-2Pedestrian Map Kiosk (retofit)
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Front View
Photo of existing sign
High Pressure Laminate Suppliers:
iZone Imaging 2526 Charter Oak Drive, Suite 100 Temple, TX 76502 USAToll Free 888.464.9663Local 254.778.0722Fax 254.778.0938Email: [email protected]
FOSSIL INDUSTRIES INC.44 Jefryn BoulevardDeer Park, NY 11729Phone: 631.254.9200Fax: 631.254.4172Email: [email protected]
4'-0" 3'-6"
1 1/2"
1 1/2"
2 1/2"
2'-10"
High pressure laminate panel to replace exsiting. Thickness and size to be the same as current panel.
Silver anodized, lockable snap frame with non-glare UV protecting clear lens.
1'-10"1'-8" 2" 1 1/2"eq eq1'-10"
3 1/2"
center
2"
Approximatley 6'-6"
Approximatley
ALL SIZES APPROXIMATEFABRICATOR TO FIELD VERIFY SIZES
28
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
03.26.15 Preliminary Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Vx-1, Vx-2 and Vx-3Vinyl on glass
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
Engineering andComputer Center
Engineering andComputer Center
ECC ECC BuildingConnector
Path
Access to Building Connector Path
Vx-3Vx-2Vx-1Vinyl on Glass
Building IdentificationVinyl on Glass
Building Identificationwith Building Connector Path
Vinyl on Glass BuildingConnector Path
900 3rd Ave S 900 3rd Ave S
08 Surface applied white vinyl
08 Surface applied white vinyl
01 Surface applied vinyl
08 Surface applied white vinyl
01 Surface applied vinyl
05 Surface applied vinyl
07 Surface applied vinyl
2 1/2"1 1/4"1 1/4" 7/8"
3/4"
1 1/4"2"
1" 1"
3/4"
1 1/4"1 1/4"
1 1/4"1"
1'- 4" eqeq4 3/4"
center
center
4'-8" 4'-8"
1'- 4"
9"1"
eq
eq
1"1"
5/8"5/8"
29
04.28.15 Final Client Review
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
05.11.15 Revised Design
3/4" = 1'-0" (on a 11" x 17" paper)
SCALE
Rx-1, Rx-2 & Rx-3Regulatory ,Accessible Entrance Guideand Staff/Student Parking
Non-Illuminated
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.1236
RESERVEDFOR
VISITORS
P LotEmployee ParkingPermit Required
Mon-Thur 7am-7pm Fri 7am-3pm
NO PARKING 3AM-7AM
Enforced Year Round
Top View
Top View
Rx-2Rx-1Front View Front View
Rx-3Front ViewSide View
9"
center
1'-5"
2"
2"
1 1/2"
2 1/4"
1 3/8"1"
4"6 1/2"
eq
eq
1'-6"
Single-sided aluminum panel. Mechanically attached to post with stainless steel fasteners. Back side is painted Dark Grey.
02
02
01
08
2" x 2"square aluminum post painted to match Light Gray.
Install sign by directly embedding posts in below grade concrete footing. Footing depth to be engineered by fabricator.
Stone or mulch bed surround (to match existing landscaping) extending a minimum of 1' beyond sign to protect sign from lawn maintenance.
04 2" x 2"square aluminum post painted to match Light Gray.
04
08 Surface applied reflective vinyl copy
08
09
Parking symbol, surface applied reflective white and parking blue vinyl.
Single-sided aluminum panel. Mechanically attached to post with stainless steel fasteners. Back side is painted Dark Grey.
Single-sided aluminum panel. Mechanically attached to post. Back side is painted Dark Grey.
White engineer grade reflective background with digitally printed translucent graphic colors and clear UV/anti-graffiti overlay (3M inkjet or Oracal Orajet digially printing process).
FINAL LAYOUT TO BE DETERMINED
02
08 Surface applied reflective vinyl arrow
08
09
Barrier free symbol, surface applied reflective white and parking blue vinyl.
1'-0"
center
5'-10"
1'-1"
2"
2"
1 3/4"
3"
5 1/2"
1'-2"
4'-3"
22°
2'-3 1/2" 2'-4 3/8"
1'-5 7/8"
center
7'-7"
5"
11"
1 1/4"
3 3/8"
2"
3 1/2"
1"1 3/8"
1"1 1/2"
3"
1 1/4"3/4"
1 1/4"3/4"
1 1/4"2 1/8"1 1/8"
30
04.28.15 Final Client Review05.08.15 New Sign Type
NORTH CAMPUS
ATHLETIC COMPLEX
St. CloudState
University
NEXT LEFT
St. CloudState
University
NEXT RIGHT
St. CloudState
University
St. CloudState
University
01 Red
02 Dark Gray
03 Medium Gray
04 Light Gray
05 Yellow
06 Caution Red
07 Black
08 White
09 Parking Blue
10 Wave Pattern
11 Granite
COLOR
Not to scale(on a 11" x 17" paper)
SCALE
MNDOT SignsProposed layouts
SIGN TYPE
DATE DESCRIPTION
109 East Front Suite 304Traverse City, MI 49684
231 947.123631
04.28.15 Final Client Review05.08.15 Revised Layout