HIGH RATE SAND FILTERSO W N E R S M A N U A L
INSTALLATION, OPERATION & PARTS
MODELST-150BP-1 T-170BP-1 T-200BP-1 T-240BP-1 T-300BP-2
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
www.starite.com
Union City, TN Delavan, WI Mississauga,ON
2005, Sta-Rite Industries S242 (Rev. 12/2/05)
This manual should be furnished tothe end user of this filter; its use willreduce service calls and chance ofinjury and will lengthen filter life.
R E C I R C U L A T E
BA
CK
WASH
E
WA
STE
F I L T E R
Aquatools.WATERFORD, WI.
53185USA
729 0294
Pentair Pool Products, Inc.1620 Hawkins Ave.
Sanford, NC 27330
Tel 919-774-4151 Fax 919-774-4841
S242 (Rev. B 6/28/06)
7/25/2019 Sta Rite CristalFloOM
2/32
2
HIGHRATESANDFILTERS
To avoid unneeded service calls, prevent possible injuries, and get the mostout of your filter, READ THIS MANUAL CAREFULLY!
The Sta-Rite Top Mounted Series High Rate Sand Filter:
Is designed to filter water for swimming pools.
Is an excellent performer; durable, reliable.
Table of Contents
Safety Instructions .....................................................................................2-3
Dimensions/Specifications ............................................................................4
General Information .....................................................................................5
Installation ................................................................................................5-7
Filter Mount/Piping ....................................................................................5
Filter Set-up ...............................................................................................6
Loading Sand Media ..................................................................................6
Valve Installation.......................................................................................6
Startup/Operation......................................................................................7
Maintenance ................................................................................................8
Water Maintenance ...................................................................................8
Storage/Winterizing .................................................................................8-10
Mult-Port Valve Service .............................................................................9
Drain Fitting Installation/Removal............................................................10
Troubleshooting Guide................................................................................11
Repair Parts List .....................................................................................12-13
Pressure Drop Curve...................................................................................14
Warranty ....................................................................................................15
READANDFOLLOWSAFETY
INSTRUCTIONS!
This is the safety-alert symbol. When you see this symbol on your valveor in this manual, look for one of the following signal words and be alert to thepotential for personal injury.
warns about hazards that will cause serious personal injury,death or major property damage if ignored.
warns about hazards that can cause serious personal injury,death or major property damage if ignored.
warns about hazards that will or can cause minor personal in-jury or property damage if ignored.
The label NOTICE indicates special instructions which are important but notrelated to hazards.
Carefully read and follow all safety instructions in this manual and on filter.
Keep safety labels in good condition.Replace missing or damaged safety labels.
7/25/2019 Sta Rite CristalFloOM
3/32
3
Incorrectly installed or tested equipment may fail, causing se-vere injury or property damage. Read and follow instructionsin owner's manual when installing and operating equipment.Have a trained pool professional perform all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a swimming pool installation.3. Trapped air in system can cause explosion. BE SURE all air is out of system
before operating or testing equipment.
Before pressure testing, make the following safety checks:
Check all clamps, bolts, lids, and system accessories before testing.
BE SURE all air is out of system before testing.
Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
Water pressure for test must be less than 25 PSI (172 kPa).
Water temperature for test must be less than 95 F. (35 C).
Limit test to 24 hours. After test, visually check system to be sure it is readyfor operation. Remove trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For
non-Sta-Rite equipment, consult manufacturer.
Hazardous Pressure!Can cause severeinjury or majorproperty damage fromtank explosion.
BEFORE WORKINGON FILTER:
1. Stop pump.
2. Open air releasevalve.
3. Release all pressurefrom system.
Filter pumps requirehazardous voltagewhich can shock, burn,or cause death.
BEFORE WORKINGON PUMP OR MOTOR
Disconnect power tomotor.
7/25/2019 Sta Rite CristalFloOM
4/32
4
See Page 14 for Pressure Drop Curve.
RECOMMENDED SAND GRADES:
Use only: #20 Silica Sand, Size Range .40-.55mm., Uniformity Coefficient lessthan 1.75.
NOTICE: Use of other sands will reduce filter performance, may damagepump, and will void warranty.
Recommended:
1. Wedron Silica/Best Sand Co., Sand Grade: Wedron .45-.55mm., EffectiveSize .46mm, Uniformity Coefficient 1.22.
2. U.S. Silica - Silurian Filter Sand, Sand Grade.45-.55 mm., Effective Size.48mm, Uniformity Coefficient 1.18.
Max.Filter Filter Flow RateModel Size in GPM (L/M)
Dia. in Area in Ft2
Inches (mm) (M2)
T-150BP-1 15 (381) 1.26 (.117) 25.2 (95)
T-170BP-1 17 (432) 1.57 (.146) 31.5 (123)
T-200BP-1 20 (508) 2.18 (.203) 43.6 (165)
T-240BP-1 24 (610) 3.10 (.288) 62.0 (234.7)
T-240BP-2 24 (610) 3.10 (.288) 62.0 (234.7)
T-300BP-2 30 (762) 4.90 (.455) 98 (371)
Turnover in Hours SandFilter Volume
Model 6 8 10 12 in lbs. (kg.)gal. (L) gal. (L) gal. (L) gal. (L)
T-150BP-1 9,070(34 330) 12,100(45 799) 15,120(57 229) 18,144(68 675) 100 (45.4)
T-170BP-1 11,340(42 922) 15,120(57 229) 18,900(71 536) 22,680(85 844) 150 (68)
T-200BP-1 15,700(59 424) 20,930(79 220) 26,160(99 016) 31,390(118 811) 200 (90.7)
T-240BP-1 22,230(84 481) 29,760(112 642) 37,200(140 802) 44,640(168 962) 300 (136)
T-240BP-2 22,230(84 481) 29,760(112 642) 37,200(140 802) 44,640(168 962) 300 (136)
T-300BP-2 35,280(133 535) 47,040(178 046) 58,800(222 558) 70,560(267 070) 600 (272)
Base Base PipingWidth Length Port
Filter Model No. A B C D (E) (F) Size
T-150BP-1 27 (686) 33-13/16 (859) 15-3/4 (400) 24-11/16 (627) 13 (330) 16-1/4 (413) 1-1/2 SLIP
T-170BP-1 29-9/16 (751) 36-3/8 ( 924) 17-3/4 (451) 27-1/4 (692) 13 (330) 16-1/4 (413) 1-1/2 SLIP
T-200BP-1 31-5/8 (803) 38-1/2 ( 978) 20-3/4 (527) 29-3/8 (746) 13 (330) 16-1/4 (413) 1-1/2 SLIP
T-240BP-1 35-3/16 (897) 42 (1067) 24-3/4 (629) 32-7/8 (835) 16-7/8 (429) 21 (533) 1-1/2 SLIP
T-240BP-2 35-1/4 (895) 44-1/2 (1130) 24-3/4 (629) 32-7/8 (835) 16-7/8 (429) 21 (533) 2 (NPT)
T-300BP-2 42 (1067) 51-1/4 (1302) 31 (787) 39-5/8 (1008) 16-7/8 (429) 21 (533) 2 (NPT)
TABLE I - FILTER OPERATIONAL DATA
TABLE II - DIMENSIONAL DATA In Inches (mm)
*NOTE: 1 cubic foot of sand weighs approx. 100 lbs. (45.4 kg). Do not use finer orcoarser grade than recommended for best performance.
CDia. B
AD
2.88 (73)
Pump Inlet 1-1/2"
Waste Outlet 1-1/2"Union connection
Return Outlet1-1/2" Slip
E,F1355 1094
C
D
A
B
9.25 (235)
2" NPT Outlet(Waste)
2" NPT Inlet(Pump)
2" NPTOutlet(Return)
E,F
8.00(203)
1356 1094
Fig. 1: Dimensions, T-150BP-1,T-170BP-1 T-200BP-1, T240BP-1
Fig. 2: Dimensions, T-300BP-2,T240BP-2
7/25/2019 Sta Rite CristalFloOM
5/32
5
GENERAL INFORMATION
Clean a new pool as well as possible before filling pool and operating filter.Excess dirt and large particles of foreign matter in the system can cause seriousdamage to the filter and pump.
NEVER test this filter with compressed air.
Do not operate filter at water temperatures above 95F (35C).NEVER operate this filter system at more than 50 pounds per square inch
(50 PSI/345 kPa) pressure!
INSTALLATION
Installation of filter should only be done by qualified, licensed personnel.
For assembly and filling instructions, see page 6.
Filter mount must: Provide weather and freezing protection.
Provide space and lighting for easy access for routine maintenance. (SeeFigures 1 and 2, Table II, Page 4, for space requirements.)
Be on a reasonably level surface and provide adequate drainage.
Be as close to pool as possible to reduce line loss from pipe friction.
Piping: Piping must conform to local/state plumbing and sanitary codes.
Use pipe joint sealing compound or teflon tape on all male connections ofmetal pipe and fittings (except unions). Use teflon tape or Plasto-Joint Stik1 onall male connections of plastic pipe and fittings. DO NOT use pipe dope onplastic pipe; it will cause the pipe to crack. Do not use sealant or tape onunions assemble them dry and hand tight.
Do not damage union sealing surfaces and O Rings.
Support pipe independently to prevent strains on filter or valve.
Use 1-1/2 or 2 pipe to reduce pressure losses as much as possible.
NOTICE: Filter may be located away from pool, but for adequate flow largerpipe may be needed. Check local codes when considering remote installation.
Fittings restrict flow; for best efficiency use fewest possible fittings.
Keep piping tight and free of leaks: pump suction line leaks may cause trappedair in filter tank or loss of prime at pump; pump discharge line leaks may showup as dampness or jets of water.
When unions are provided, use as follows for leak free connections:
1. O-Ring and sealing surfaces must be clean.
2. Assemble hand tight only (no wrenches).
3. No pipe compound or teflon tape on unions.
Valves: A check valve installed between filter and heater will prevent hot water from
backing up into filter and deforming internal components.
Use care before assembly not to damage union sealing surfaces or O Ring.
Wastewater: Be sure all provisions for waste water disposal meet applicable local, state or
national codes. 100 gallons (379 liters) or more of pool water will be dis-
charged during filter backwashing. Do not discharge where water will cause
flooding or damage.
1 Lake Chemical Co., Chicago, IL
7/25/2019 Sta Rite CristalFloOM
6/32
6
Filter Setup
Assembly: See Figures 2 through 5 for filter assembly.
Loading Sand Media1.To keep sand out of collector assembly, place plastic sand shield over top
of collector tube before pouring sand into filter (See Figure 5).
2.To support laterals and prevent lateral breakage during loading, fill tankabout half full of water before loading sand.
3.Pour sand into filter tank. See Page 4, for correct type and quantity of sandto use.
NOTICE: Make sure gasket area on top of tank is free of sand before in-stalling valve and clamp.
4.Before installing valve, double-check that correct quantity of sand hasbeen loaded (see Page 4).
5.Remove plastic sand loading shield and keep for future use.
Valve Installation:
See Figures 6, 7, and 8
1. Install O-Ring on valve flange; make sure O-Ring is clean, dry, and hasno nicks, tears, or scrapes.
2. Make sure tank and valve flanges are clean and free of sand; put valveon top of tank. Vertical pipe of collector assembly inserts into base ofvalve.
3.Install clamp; make sure knob is positioned for easy access for filtermaintenance. Valve port labeled PUMP should point toward pump.
4.Tighten clamp knob until clamp ends (under bolt) are 1/4 (6mm) apart.Tap around outside of clamp with a mallet to help seat clamp.
Hazardous pressure. Clamp will not hold unless it is
seated properly! DO NOT START PUMP until clamp ends are 1/4(6mm) apart or less.
5.If clamp will not pull up to 1/4 (6mm) gap, wait 15-30 minutes andretighten. Tap clamp gently with mallet to help seat clamp.
6.Connect pipe from pump discharge to valve port labeled PUMP; useunion half provided. Assemble union as follows for leakfree operation:
A. O-Ring and sealing surfaces must be clean.
B. Assemble hand tight only (no wrenches).
C. NO pipe compound or teflon tape on unions.
7.Complete all plumbing connections (see Page 5 for piping require-ments).
A. Pipe from valve RETURN port to pool return.B. Pipe from valve WASTE port to waste.
C. Suction piping from pool to trap inlet on pump.
8.System is ready for startup.NOTICE: If there are leaks from beneath valve/clamp area, STOPPUMP, release all pressure, remove clamp and valve and clean sealingsurfaces.
B. Insert assembly
into top of
filter tank.
A. Insert first lateral into socket;twist clockwise 1/4 turnto lock lateral into hub.
Lateral is correctly installed when slots face down.
731 0294
C. Hold assembly up
near top of tank and
add remaining
laterals.
732 0294
D. After all
laterals are
securely in
sockets,
position
assembly on
centering
boss in
bottom of
tank.
733 0294
SAND
::::::::::::::::::::::::::::::::::::::::::::::::
::::::::::::::::::::::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:
:
:
:
:
:
:
:
:
:
:
:::::::::::::::::::::::::::::::::::::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
::
:
:
::
:
:
:::
:::::
::::
:
:::
::::
::::
::::
::::
::::
::::
::::
::::
::::::::
::::
::::
::::
::::
:::: :
:::
::::
:::: :
:
::
::
::
:::
:
::
::
::
::
:::
:
::::
::::
:::: :
::
:
:::
:
::::
:::
:
:::
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
Fill tank
abouthalf fullof waterbeforeaddingsand.
Sand Shieldkeeps collectorhub assemblyclean whenloading filter.
734 0294
Fig. 2
Fig. 3
Fig. 4
Fig. 5
7/25/2019 Sta Rite CristalFloOM
7/32
7/25/2019 Sta Rite CristalFloOM
8/32
8
MAINTENANCE
General: Wash outside of filter with a mild detergent and water. Rinse off with hose.
NOTICE: DO NOT use solvents to clean filter; solvents may damage plasticcomponents in system.
Inspect sand bed at least once a year to remove foreign material which has notbeen backwashed out of system.
NOTICE: When the sand bed gets hard and crusty on top, remove all the oldsand and replace it with new sand.
Weekly Pool Equipment Inspection:1. Check pressure during operation. When pressure is 5 to 7 PSI (34.5 to 48
kPa) higher than initial operating pressure, backwash filter (see instructionsunder Startup/Operation, Page 7).
2. Except during hot weather with heavy swimmer loads, operating filter 6 to 12hours per day should be sufficient. Carefully monitor water chemical balanceand follow recommendations of your local pool professional.
Water Maintenance Keep water level at least 2 (51mm) above bottom of skimmer opening.
Failure to do so can allow air to enter system, causing pump to lose primeand air to enter filter.
Maintain pH at 7.2 to 7.6 in pool.
To prevent damage to system components, keep water temperature below95 F. (35 C) at all times.
Vacuum Pool:1. Fill vacuum hose by submerging in water from one end to the other.
2. To vacuum, insert hose into skimmer suction manifold or into vacuum linein pool wall. See instructions provided by pool builder or pool manufac-
turer. Start pump, making sure it is primed and pumping.3. After vacuuming, clean pump trap to remove accumulated debris, then
check filter pressure gage. If reading is 5 to 7 PSI (34.5 to 48 kPa) higherthan initial operating pressure, backwash filter.
Lower or Drain Pool1. Turn pump OFF; set valve handle to WASTE.
2. Use vacuum cleaner hose and head.
3. Start pump; run until pool is lowered to desired level.
4. Turn pump OFF; set valve handle to FILTER.
5. Start pump.
STORAGE/WINTERIZINGPool chemicals may give off corrosive fumes. Store chemicals
away from system in a well ventilated area.
NOTICE: Allowing water to freeze will damage filter and void warranty. If an-tifreeze is needed, use propylene glycol; its plastic compatible and non-toxic.Follow manufacturers instructions. Do not use ethylene glycol based anti-freeze its toxic and it may damage plastic components.
1. Open all system valves. Set multiport valve at WINTERIZE to allow air pas-sage to all ports.
RECIRC ULATE
BACKWASH
CLOSE
D
WIN
TERIZ
E
WASTE
FILTER
RINSE
REC
I RCULATE
BACKWASHCLO
SED
WIN
TERIZE
WASTE
FILTER
RINSE
Fig. 10: Valve settings to lowerpool water level. Stop pumpbefore changing valve position.
REC
I RCULATE
BACKWASHCLOSE
D
WINTER
IZE
WASTE
FILTER
RINSE
Fig. 11: Valve setting for winterstorage. Stop pump beforechanging valve position.
7/25/2019 Sta Rite CristalFloOM
9/32
9
2. Remove drain plug from filter.
3. Drain filter tank completely and replace drain cap (Figure 13, Page 10).
4. Cover with plastic or tarpaulin to protect from weather, but do not seal fromair circulation.
5. Protect from freezing.
Startup for Winterized Equipment:1. Remove any temporary weather protection placed around system for shut-
down.
2. See Startup, Page 7, for reactivation of the filter.
3. Inspect all electrical wiring to pump for damage or deterioration over theshutdown period. Have a qualified serviceman repair/replace wiring asneeded. Inspect and tighten all watertight connections.
4. Open all valves in suction and return piping.
5. Remove any winterizing plugs in system.
6. Drain all winterizing chemicals (if used) from system; flush system.
7. Close all drain valves and replace all drain plugs in system (see Page 10).
8. Fill pool with water to proper level (see pool manufacturers instructions).
MULTI-PORT VALVE SERVICE
Hazardous pressure. Stop pump and release all pressure from sys-tem before working on filter, valve, or clamp. Filter and valve design allows airto bleed off automatically in normal service. However, always be sure pressure isoff system before working on filter, valve or clamp.
NOTICE: if Multi-Port valve is below pool water level, close suction and dis-charge valves before disassembly to prevent draining pool.
Handle Replacement:1. Stop pump.
2. Place handle in FILTER position.
3. Remove pin (Key 1, Figures 12A and 12B) to disconnect handle. If it cannotbe removed by hand, use a hammer and center punch and lightly tap it out.
4. Remove handle; replace with a new one. Be sure new handle is in FILTERposition.
5. Replace pin.
Lid and Plug replacement:1. Remove Handle (see Handle Replacement above).
2. Remove plug:
A. Remove all screws and nuts (Key Nos. 2 and 6, Figures 12A and 12B).
B. Remove lid (Key No. 3) by pulling straight up while holding plug shaft(Key No. 5) down with thumb.
3. Inspect Internal Parts:
Inspect plug and gasket spring, O-Rings, and internal washers (Key No. 4).Replace if necessary.
RECIRCULATE
BA
CKWASH
CLOS
ED
WINTERIZE
WA
STE
FILTE
RRINSE
1
1A
2
3
4
5
6
Aquatools.WATERFORD, WI.
53185USA
744 0294
Fig. 12A: Valve Disassembly(1-1/2 Multiport Valve)
Fig. 12B: Valve Disassembly(2 Multiport Valve)
1344 1094
1
1A
2
3
5
6
4
7/25/2019 Sta Rite CristalFloOM
10/32
10
4. Reassemble Valve:
A. Replace plug gasket and shaft, mounting spring, washers, and O-Ring onplug shaft. Lubricate O-Ring with Amojel.
B. Replace lid; match screw holes in lid and body.
C. Press down on lid to allow screws to engage nuts; tighten each nut se-curely.
D.Replace top washer (Key No. 1A) and handle, making sure indexing pinon plug shaft points in same direction as pointer on handle. Replace han-dle pin.
E. Tighten all lid screws to 55 inch-lbs. (63.4 kg-cm) torque.
Valve Removal
Hazardous pressure. Stop pump and release all pressure from sys-tem before working on filter, valve, or clamp.
NOTICE: If multi-Port Valve is below pool water level, close suction and dis-charge valves before disassembly to prevent draining pool.
1. Disconnect piping from pump and pool.
2. Remove clamp.
3. Remove valve from filter top.4. To reinstall valve, follow instructions, Figures 6 and 7, Page 7. BE SURE to
follow clamp tightening instructions.
Drain Fitting Installation/Removal
NOTICE: If pool is above height of filter, first close valves in pump suction andreturn lines to prevent draining pool. If there are no shutoff valves installed, dis-connect suction and return lines and raise ends above pool water level.
1. Installation: See Figure 13.
2. To Drain Filter:
A. Remove drain cap. Lateral tube should remain in place inside drainopening to prevent sand from draining out.
B. Open union coupling on backwash port of Multi-Port valve. This willallow air into filter and allow water to drain from filter tank.
C. Replace cap when tank is empty.
3. Removing Sand From Filter:
A. Remove both drain cap and slotted lateral tube (see Figure 13). Sand andwater will drain from tank.
B. To completely flush filter tank of sand, remove top clamp and multiportvalve and flush the inside of the tank with a hose.
C. Thoroughly clean sand from all parts and from tank drain opening be-fore reassembling drain fitting.
About 1"
Small
O-Ring
Open end
of lateral
Seat small
O-Ring
Large
O-Ring
End of lateral is
flush with end of
drain fitting 746 0294
Figure 13: Drain Fitting Assembly.This assembly allows water to drain
without losing the sand out of the fil-ter tank.Make sure all surfaces are clean andfree of sand. Dont cross thread cap;dont overtighten cap.
7/25/2019 Sta Rite CristalFloOM
11/32
11
TROUBLESHOOTINGGUIDE
1. Short Cycle between backwashes:NOTICE: Time between backwashes will vary with each installation and be-tween different areas of the country. Ask installer about normal backwash in-
terval in your area. The following causes and remedies are for cycle timesshorter than normal for your area.
A. Flow rate too high or filter too small; consult dealer for system sizing rec-ommendations.
B. Water is chemically out of balance; consult pool serviceman.
C. Excess dirt/dust in pool; vacuum pool directly to waste.
D.Body oil/lotion build-up in filter; consult dealer for chemical filter clean-ers and follow cleaner manufacturers instructions.
E. Filter inadequately backwashed. See instructions underStartup/Operation, Page 7.
F. Algae in pool. Consult pool professional about proper chemical mainte-nance.
G.Residual chlorine level too low. Consult pool professional about properchemical maintenance.
H.Inspect filter sand for solidification caused by dust, calcium, skin oils, ofsuntan lotions.
2. Low Flow:A. Pipe blocked downstream from filter; remove obstruction.
B. Piping too small; use larger pipe (consult dealer for sizing).
C. Plugged pump; plugged hair and lint trap or skimmer basket. Clean thor-oughly.
3. Pool Water Not Clear:
A. Water is chemically out of balance; consult pool professional.B. Filter is too small; consult dealer about equipment sizing.
C. Sand in pool means broken lateral. Drain both water and sand out oftank. Remove valve; follow procedure under Filter Setup, Page 6, andinstructions with new lateral to replace broken part.
To avoid severe injury or major property damage, followinstructions under 'Valve Installation', Figures 6 and 7, Page 7).
1. Follow valve removal procedure, Page 10.
2. Replace lateral according to instructions supplied with new lateral.
3. Reassemble filter according to instructions under Filter Setup, Page 6.
Hazardous pressure.Can cause severe in-jury or major propertydamage from tankblow up.
Release all pressureand read instructionsbefore working on filter.
7/25/2019 Sta Rite CristalFloOM
12/32
R E C I R C U L A T E
BA
CK
WASH
E
WA
STE
F I L T E R
Aquatools.WATERFORD,WI.
53185USA
1
23A3
4
5
6
7
8
9
10
11
12
13
757 0294
Model
Key No.No. Description Used T-150BP-1 T-170BP-1 T-200BP-1 T-240BP-1 T-300BP-2
1 Multiport Valve, Top Mount(Includes Key Nos. 2 and 3) 1 WC112-148A WC112-148A WC112-148A WC112-148A 14971-TM-22-L
2 O-Ring, Valve Flange 1 U9-369 U9-369 U9-369 U9-369 U9-3693 V-Clamp w/Knob 1 WC119-87A WC119-87A WC119-87A WC119-87A WC119-87A
4 Clamp Knob 1 WC36-22 WC36-22 WC36-22 WC36-22 WC36-225 Collector Hub Assembly 1 24200-0110 WC137-516P WC137-517P WC137-519P 24205-00106 Lateral 8 24600-0003 24600-0003 24600-0003 24700-0075 21180-15307 Filter Tank 1 24200-1000 24201-1000 24203-1000 24204-1000 24205-10008 O-Ring, Lateral 1 U9-370 U9-370 U9-370 U9-370 U9-3709 Drain Lateral 1 24201-0058 24201-0058 24201-0058 24201-0058 24201-0058
10 O-Ring, Drain Cap 1 U9-371 U9-371 U9-371 U9-371 U9-37111 Drain Cap 1 14965-0025 14965-0025 14965-0025 14965-0025 14965-002512 Pedestal 1 23910-0005B 23910-0005B 2 3910-0005B 23900-0105B 23900-020513 Filter Tank Assembly 1 24200-0100 24201-0100 24203-0100 24204-0100 24205-0100 Union Coupling Package 3 C198-3M C198-3M C198-3M C198-3M Sand Loading Disc 1 24201-0043 24201-0043 24201-0043 24201-0043 24201-0063 Model & Instruction Label 1 32155-4115A 32155-4115B 32155-4115C 32155-4115D 90000-1329 Clamp Warning Decal 1 32165-4030 32165-4030 32165-4030 32165-4030 32165-4030 Information Decal 1 32155-4112 32155-4112 32155-4112 32155-4112 32155-4112
Not Illustrated.
12
REPAIR PARTS TANKS
T-150BP-1, T-170BP-1,
T-200BP-1, T-240BP-1, T-
300BP-2
7/25/2019 Sta Rite CristalFloOM
13/32
13
2
3
4
7
12
12A
9A
10
8
13
14
18
19
17
6
15
16
11
1343 1094
14
15
16
RECIRCULATE
BA
CK
WASH
CLOS
ED
WINTERIZE
WA
STE
FILTERRINSE
1
2
3
4
5
6
7
8
9A
10
11
9B
13
12
REPAIR PARTS MULTI-PORT VALVES
WC112-148A #14971-TM-22-L
Key PartNo. Description Qty. WC112-148A 14971-TM-22-L
1 Valve Handle Decal 1 14965-0021 2 Handle 1 14962-0032 14971-SM10E13 Dowel Pin 1 35857-0021 14971-SM10E24 Washer 1 14965-0007 14971-SM10E35 Operating Instruction Decal 1 14965-0020 6 Screw 37337-3056(7) 14971-SM10E4(10)7 Valve Cover 1 14965-0011 14971-SM20E68 O-Ring 1 35505-1228 14971-SM10E10
9A Washer 2 14965-0007 14971-SM10E89B Washer 1 14965-0007 10 Spring 1 14965-0006 14971-SM10E911 Pressure Guage 1 15060-0000T 15060-0000T12 Plug & Gasket Assembly 1 14965-0028 14971-SM20E11
12A Gasket 1 14971-SM20E1213 Cover O-Ring 1 35505-1275 14971-SM20E714 Valve Body Assembly 1 14965-0013 14971-SM20E1315 Nut 35407-0071(7) 14971-SM10E14(10)16 Tank Flange O-Ring 1 U9-369 U9-36917 Sight Glass Gasket 1 14971-SM20E1718 Sight Glass 1 14971-SM10E1619 Stand Pipe O-Ring (EPDM) 1 35505-1243
7/25/2019 Sta Rite CristalFloOM
14/32
14
0 20 40 60 80 100 120
2
4
6
8
10
12
14
16
Capacity (GPM)
P.S.I.
Loss
T-150BP-1
T-170BP-1,T-200BP-1
T-300BP-2
T-240BP-1
Figure 14 Pressure Drop Curve - Filter Position
7/25/2019 Sta Rite CristalFloOM
15/32
CREATE A RECORD OF YOUR WARRANTY AT STA-RITE:
Complete a warranty registration at www.staritepool.com by clicking on Register Products and selecting Sta-Rite Pool OR
Complete bottom portion completely and mail within 10 days of installation to Sta-Rite, Attn.: Pool Warranty Dept., 293 Wright St., Delavan , WI 53
Warranty Registration Card
Name
Address
City State Zip
Installation (or Purchase) Date
Product Purchased
Model Number
New installation Replacement
Years pool has been in service less than 1 1-3 3-5 5-10
This product was purchased from:
Company name
Address
City State Zip
STA-RITE LIMITED WARRANTY
For technical information about this product, contact the installer or call Sta-Rite at 262-728-9181.
Visit www.staritepool.com
for more information about Sta-Rite products listed above to locate a Sta-Rite dealer near you
Product Specific Warranties (from date of installation)
Product Limited
Family Warranty Exceptions
Filters 1 Year System 3 Tank Bodies - 10 Yrs
Filter Valves 1 Year
Pumps 1 Year
Heaters 2 Years *Commercial Application - 1 Yr
Controls 1 Year
Above Ground Systems 1 Year
Lights and Niches 1 Year Lamps and Bulbs - 90 Days
White Goods 1 Year
Maintenance Equipment 90 Days
Drainer/Utility Pumps 90 Days
Replacement Parts 90 Days
Cleaners: Lil Shark 1 Year
Cleaners: Calypso 1 Year
Cleaners: Pool Shark 2 Years Footpad and Seal Flaps - 1 Yr
Cleaners: Great White 2 Years
* Commercial and multi-family application.
Retain this warranty certificate in a
safe and convenient location for your records.
Pumps, filters, skimmers, underwater lights (excluding bulbs), ac-
cessories and fittings manufactured by Sta-Rite are warranted tobe free of defects in material and/or workmanship for one (1) year
from the original date of installation.
The foregoing warranties relate to the original consumer purchaser
(Purchaser) only. Sta-Rite Industries shall have the option to re-
pair or replace the defective product, at its sole discretion.Purchasers must pay all labor and shipping charges necessary to
replace the product covered by this warranty. Requests for war-ranty service must be made through the installing dealer. This war-ranty shall not apply to any product that has been subject to
negligence, misapplication, improper installation or maintenance,
or other circumstances which are not in Sta-Rites direct control.Failure to have product installed by a professional in compliance
with local codes will void any and all manufacturers warranty.
This warranty sets forth Sta-Rites obligation and Purchasers ex-clusive remedy for defective products.
STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR-RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR APARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THEDURATION OF THE APPLICABLE EXPRESS WARRANTIES
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental orconsequential damages or limitations on how long an implied war-
ranty lasts, so the above limitations or exclusion may not apply to
you. This warranty gives you specific legal rights and you may alsohave other rights which vary from state to state.
Supersedes all previous publications.
S4877PS (Rev. 7/21/04
7/25/2019 Sta Rite CristalFloOM
16/32
7/25/2019 Sta Rite CristalFloOM
17/32
7/25/2019 Sta Rite CristalFloOM
18/32
ENREGISTREZVOTRECERTIFICATDEGARANTIECHEZSTA-RITE:Remplissezleformulairedenregistrementdegarantiedisponiblesurlesitewww.staritepool.comencliquantsurRegisterProducts,puissurSta-RitePoolOU
Remplissezlecouponci-dessousetenvoyez-leparlapostedansles10joursaprslinstallationSta-Rite,lattentionduServicedesgarantiesdepiscine,293WrightSt.,Delavan,WI53115
Cartedenregistrementdegarantie
Nom
Adresse
VilleProvinceCodepostal
Datedinstallation(oudachat)
Produit
Numrodemodle
PremireinstallationRemplacement
Annesdutilisationdelapiscinemoinsde1an1-33-55-10
Magasinoleproduitatachet:
Nomdelacompagnie
Adresse
VilleProv.Codepostal
GARANTIELIMITESTA-RITE
Pourobtenirlesdonnestechniquesduproduit,communiquezaveclinstallateurouappelezSta-Riteaunumro(262)728-9181. VisiteznotresiteWeb:www.staritepool.com
VousytrouverezunefoulederenseignementssurlesproduitsSta-Ritementionnsci-dessus
VoustrouverezladresseduconcessionnaireSta-Riteleplusprsdechez-vous
Garantiesparticulires(envigueurcompterdeladatedinstallation)
FamilleGarantiedeproduitlimiteExceptions
Filtres1anSystme3rservoirs10ans
Vannesdefiltre1an
Pompes1an
Chauffe-eau2ans*Installationcommerciale1an
Dispositifsdecommande1an
Systmeshors-sol1an
Appareilsdclairage1anLampesetampoules90jours
ProduitsWhite1an
Matrieldentretien90jours
Purgeur/pompes
usagegnral90jours
Picesderemplacement90jours
Nettoyeurs:LilShark1an
Nettoyeurs:Calpyso1anNettoyeurs:PoolShark2ansBrosseetvoletstanches-1an
Nettoyeurs:GreatWhite2ans
*Installationscommercialesetenimmeublescollectifs.
Conservezcecertificatdegarantiedans
unendroitsretaccessiblepourconsultation.
Lespompes,lesfiltres,lescumoires,lesappareilsdclairageim-mergs(lexceptiondesampoules)etlesraccordsfabriqusparSta-Ritesontgarantiscontretoutdfautdematrielet/oudefabricationpendantun(1)ancompterdeladatedelapremireinstallation.
Cettegarantiecouvreleconsommateuracheteur-utilisateurinitial(Acheteur)seulement.Sta-RiteIndustriesrpareraouremplacera,sadiscrtion,toutproduitdfectueux.Lacheteurdevrapayerlesfraisdemain-duvreetdexpditionlisauremplacementdunproduitcou-vertparlagarantie.Toutedemandevisantleservicedelagarantiedoittrefaiteparlintermdiaireduconcessionnaireinstallateur.Laprsentegarantienecouvrepaslesproduitsendommagslasuitedunengli-gence,dunusageabusif,duneinstallationoudunentretiennoncon-formeoudetouteautrecirconstancehorsducontrledirectde
Sta-Rite.Silesproduitsnesontpasinstallsparunprofessionneletenconformitaveclescodeslocaux,lesgarantiesdufabricantserontnulles.
LaprsentegarantienoncelobligationdeSta-Ritedemmequelerecoursexclusifdelacheteurlgarddesproduitsdfectueux.
LASOCITSTA-RITENEPEUTTRETENUERESPONSABLEDAUCUNDOMMAGEINDIRECT,ACCIDENTELOUFORTUITDEQUELQUENATUREQUECESOIT.
LESPRSENTESGARANTIESSONTEXCLUSIVESETREMPLA-CENTTOUTESLESAUTRESGARANTIESEXPRESSES.LESGARANTIESIMPLICITES,YCOMPRISSANSTOUTEFOISSYLIM-ITER,LESGARANTIESIMPLICITESDEQUALITMARCHANDEETDAPPROPRIATIONUNUSAGEPARTICULIER,NEDOIVENTPASDPASSERLADUREDESGARANTIESEXPRESSESSTIPULESDANSLESPRSENTES.
Puisquilestinterditdanscertainesprovincesdexclureoudelimiterlesdommagesfortuitsouindirects,oudelimiterladuredunegarantieim-plicite,leslimitationsouexclusionsprcisesci-dessuspeuventnepasnesappliquer.Laprsentegarantievousconfredesdroitslgauxspcifiquesquisajoutentauxdroitsprvusdanslaprovinceovoushabitez,lecaschant.
Cettegarantieremplacetouteslesgarantiesprcdemmentpublies.
S4877PS(Rev.21/7/04)
7/25/2019 Sta Rite CristalFloOM
19/32
14
020406080100120
2
4
6
8
10
12
14
16
Capacity(GPM)
P.S.I.Loss
T-150BP-1
T-170BP-1,T-200BP-1
T-300BP-2
T-240BP-1
Figure14CourbedeChutedePression-PositionFilter
(75,7)(151,4)(227,1)(302,8)(378,5)(454,2)
CapacitGPM(LPM)
P
ertelb/po
2
(kPa)
(110,3)
(96,5)
(82,7)
(68,9)
(55)
(41)
(27,6)
(13,8)
7/25/2019 Sta Rite CristalFloOM
20/32
13
2
3
4
7
12
12
9A
10
8
13
14
18
19
17
6
15
16
11
13431094
14
15
16
RECIRCULATE
BAC
KW
ASH
CLO
SED
WINTERIZE
WASTE
FILT
ERRINSE
1
2
3
4
5
6
7
8
9A
10
11
9B
13
12
Listedespicesderechange-VanneWC112-148A#14971-TM-22-L
Rf.DescriptionQt.WC112-148A14971-TM-22-L
1Dcalcomanie-Poignedelavanne114965-00212Poigne114962-003214971-SM10E13Goupilledimmobilisation135857-002114971-SM10E24Rondelle114965-000714971-SM10E35Dcalcomanie-Instructionsdefonctionnement114965-00206Vis37337-3056(7)14971-SM10E4(10)7Couvercledelavanne114965-001114971-SM20E68Jointtorique135505-122814971-SM10E109ARondelle214965-000714971-SM10E89BRondelle114965-000710Ressort114965-000614971-SM10E911Manomtre115060-0000T15060-0000T
12Bouchonetjoint114965-002814971-SM20E1112AJoint114971-SM20E1213Jointtoriquedecouvercle135505-127514971-SM20E714Corpsdelavanne114965-001314971-SM20E1315crou35407-0071(7)14971-SM10E14(10)16Jointtoriquedelabridedurservoir1U9-369U9-36917Jointdevoyant114971-SM20E1718Voyant114971-SM10E1619Jointtoriquedelacolonnemontante(EPDM)135505-1243
7/25/2019 Sta Rite CristalFloOM
21/32
RECIRCULATE
BAC
KWAS
H
E
WAS
TE
FILTER
Aquatools.WATERFORD,WI.
53185USA
1
2
3A 3
4
5
6
7
8
9
10
11
12
13
7570294
NonIllustrs.
12
Listedespicesderechange-RservoirT-150BP-1,T-170BP-1,T-200BP-1,T-240BP-1,T-300BP-2
Modle
Rf.DsignationQtT-150BP-1T-170BP-1T-200BP-1T-240BP-1T-300BP-2
1Vanneorificesmultiples(ycomprisrf.nos2et3)1WC112-148AWC112-148AWC112-148AWC112-148A14971-TM-22-L
2Jointtoriquedelabride delavanne1U9-369U9-369U9-369U9-369U9-369
3Collier1WC119-87AWC119-87AWC119-87AWC119-87AWC119-87A4Boutondecollier1WC36-22WC36-22WC36-22WC36-22WC36-225Raccorddeconduitemontante124200-0110WC137-516PWC137-517PWC137-519P24205-00106Tubelatral824600-000324600-000324600-000324700-007521180-1307Rservoirdefiltration124200-100024201-100024203-100024204-100024205-10008Jointtoriquedetubelatral1U9-370U9-370U9-370U9-370U9-3709Tubelateraldevidange124201-005824201-005824201-005824201-005824201-005810Jointtoriquedebouchon
devindange1U9-371U9-371U9-371U9-371U9-37111Bouchondevidange114965-002514965-002514965-002514965-002514965-002512Socle123910-0005B23910-0005B23910-0005B23900-0105B23900-020513Rservoirdefiltration124200-010024201-010024203-010024204-010024205-0100Paquetderaccordsunions3C198-3MC198-3MC198-3MC198-3MDisquedechargementdusable124201-004324201-004324201-004324201-004324201-0063
tiquettedinstructions/demodle132155-4115A32155-4115B32155-4115C32155-4115D90000-1329
Autocollantdavertissement-Collier132165-403032165-403032165-403032165-403032165-4030
Dcalcomaniedeplaquerenseignements132155-411232155-411232155-411232155-411232155-4112
7/25/2019 Sta Rite CristalFloOM
22/32
11
GUIDEDEDIAGNOSTICDES
PANNES
1.Intervallesdefonctionnementcourtsentreleslavagescontre-courant:NOTA:L'intervalleentreleslavagesvarieavecchaqueinstallationetselonlesrgionsdupays.Demanderl'installateurquelssontlesintervallesnormauxpourlelavagecontre-courantdanslargion.Lescausesetlesremdesquisuivents'appliquentdesduresdefonctionnementpluscourtesquelanor- maledanslargionolapompefonctionne.
A.Ledbitdel'eauesttroplevoulefiltreesttroppetit;consulterlemarc-handpourconnatrelesrecommandationsconcernantlesdimensionsdusys-tme.
B.L'eauestchimiquementdsquilibre;consulterletechnicienenpiscines.C.Tropdesaletoudepoussiredanslapiscine;passerlapiscinel'aspirateur
etenvoyerl'eaudirectementl'gout.D.Accumulationdelotion/d'huilecorporelledanslefiltre;consulterlemarc-
handpourlesnettoyantsdefiltrechimiquesutiliseretobserverlesinstruc-tionsdufabricantdunettoyant.
E.Lefiltreestmallavcontre-courant.VoirlesinstructionssousMiseenser-vice/fonctionnementlapage7.
F.Alguesdanslapiscine.Consulterunprofessionnelenpiscinespourconnatrelabonnequantitdeproduitschimiquesutiliserdanslapiscine.G.Niveaudechlorersidueltropbas.Consulterunprofessionnelenpiscines
pourconnatrelabonnequantitdeproduitschimiquesutiliserdanslapiscine.H.Inspecterlesabledufiltrelarecherchedesolidificationscausesparla
poussire,lecalcium,l'huiledelapeauouleslotionsdebronzage.
2.Dbitfaible:A.Letuyauestbouchenavaldufiltre;enleverl'obstruction.
B.Tuyauteriestroppetites;utiliserdestuyauteriesdeplusgrosdiamtre(consul-terlemarchand).
C.Lapompeestbouche;enleverlescheveuxetlacharpieemprisonnsdanslacrpineoulepanierdel'cumoire.Bienlesnettoyer.
3.L'eaudelapiscinen'estpasclaire:A.L'eauestchimiquementdsquilibre;consulterletechnicienenpiscines.B.Lefiltreesttroppetit;consulterlemarchandpourconnatrelabonnedimen-
siondel'quipementutiliser.
C.S'ilyadusabledanslapiscine,ceciindiquequ'untubelatralestcass.Danscecas,viderl'eauetlesabledurservoirdefiltration.Dposerlavanne;procdercommeilestindiqusousMontagedufiltrelapage6etlesinstructionsfourniesavecletubelatralneufpourremplacerlapicecasse.
Pourviterdegravesblessuresoud'importantsdommagesmatriels,suivrelesinstructionssousPosedelavanne,(Figures6et7lapage7).1.Suivrelamthodededposedelavannelapage10.2.Remplacerletubelatralconformmentauxinstructionsfourniesavecle
tubeneuf.3.RemonterlefiltreconformmentauxinstructionsfigurantsousMontage
dufiltrelapage6.
Pressiondangereuse!Risquedegravesbless-uresoudedommagesmatrielsimportantsencasd'explosiondurser-voir.
Dissipertoutelapressionetlirelesinstructionsavantd'intervenirsurlefiltre.
AVERTISSEMENT
7/25/2019 Sta Rite CristalFloOM
23/32
10
4.Remontagedelavanne:A.Reposerlejointdubouchonetl'arbre,leressortdemontage,lesrondelleset
lesjointstoriquessurl'axedubouchon.Lubrifierlejointtoriqueavecdel'Amojel.B.Remettrelecouvercleenplace;assortirlestrousdesvisducouvercleavec
ceuxducorps.C.Appuyersurlecouverclepourpermettreauxvisdes'engagerdansles
crous;bienserrerchaquecrou.D.Remettreenplacelarondellesuprieure(Rf.n1A)etlapoigne,ens'as-
surantquel'axed'indexagedel'axedubouchonestorientdanslemme sensquelaflchefrappesurlapoigne.Reposerlagoupilled'immobilisa-
tiondelapoigne.E.Serrertouteslesvisducouvercleaucouplede63,4kg-cm(55lb-po).
Dposedelavanne
Pressiondangereuse.Arrterlapompeetdissipertoutelapres-sionducircuitavantd'intervenirsurlefiltre,lavanneoulecollier.NOTA:Silavanneorificesmultiplesestplusbassequeleniveaudel'eaudelapiscine,fermerlesrobinetsdestuyauteriesd'aspirationetderetouravantdeprocderaudmontageafind'empcherquelapiscinesevide.1.Dbrancherlestuyauteriesprovenantdelapompeetdelapiscine.2.Dposerlecollier.3.Dposerlavannedufiltre.4.Pourreposerlavanne,suivrelesinstructionsauxFigures6et7,page7. S'ASSURERderespecterlesinstructionsdeserrageducollier.
Dpose/reposeduraccorddevidangeNOTA:Silapiscineestplusdehuitpiedsau-dessusdufiltre,fermertoutd'abordlesrobinetsdestuyauteriesderetouretd'aspirationdelapompepourempcherdeviderlapiscine.Sicestuyauteriesnecomportentpasderobinet,lesdbrancheretlesleverplushautqueleniveaudel'eau.1.Repose:VoirlaFigure13.2.Pourviderlefiltre:
A.Dposerlebouchondevidange.Letubelatraldoitresterenplacel'in-trieurdel'ouverturedevidangepourempcherausabledeseviderdufiltre.
B.Ouvrirleraccorduniondel'orificedelavagecontre-courantdelavanneorificesmultiples.Cecipermettral'airdepntrerdanslefiltreetl'eaudecompltementseviderdurservoirdefiltration.C.Reposerlebouchonlorsquelerservoirestvide.
3.Pourenleverlesabledufiltre:A.Dposerlebouchondevidangeetletubelatralfentes(voirlaFigure13).
Lesableetl'eauseviderontdurservoir.B.Pourcompltementrincerlerservoirdefiltrationdesable,dposerlecollier
suprieuretlavanneorificesmultiplesetlaverl'intrieurdurservoiravecuntuyaud'arrosage.C.Biennettoyerlesabledetouteslespartiesdurservoiretdel'ouverturede
vidangedurservoiravantderemonterleraccorddevidange.
About1"
Small
O-Ring
Openend
oflateral
Seatsmall O-Ring
Large
O-Ring
Endoflateralis
flushwithendof
drainfitting7460294
Figure13:Raccorddevidange.Ceraccordpermetdevidangerl'eau sansquedusables'chappedurser-
voirdefiltration.
S'assurerquetouteslessurfacessontpropresetdbarrassesdesable.Nepasfausserlesfiletsdubouchon;nepastropserrerlebouchon.
Environ1pouce
Petitjointtorique
Extrmitouvertedutubelatral
Sigedupetitjointtorique
Grandjointtorique
L'extrmitdutubelatralvientrasavecl'extrmitduraccorddevidange
7/25/2019 Sta Rite CristalFloOM
24/32
9
d'antigelbased'thylne-glycol-ceproduitesttoxiqueetilrisqued'endom-magerleslmentsenplastique.1.Ouvrirtouslesrobinetsdusystme.Rglerlavanneorificesmultiplessur
WINTERIZEpourpermettrel'airdepntrerdanstouslesorifices.2.Dposerlebouchondevidangedufiltre.3.Vidertoutlerservoirdefiltration,puisreposerlebouchondevidange(voirla
Figure13,page10).4.Couvrirlerservoiravecunefeuilledeplastiqueetouunebchepourlepro-
tgercontrelesintempries.5.Leprotgerdugel.
Remiseenservicedel'quipementaprsl'hiver:1.Dposertouteslesprotectionstemporairesplacessurlesystmeavantl'hiver.2.Sereporterlapage7Miseenservicepourremettrelefiltreenservice.3.Inspectertoutlecblagelectriquepours'assurerqu'iln'apastendommag
nidtriorpendantlaprioded'arrt.Demanderuntechnicienqualifider-parerouderemplacerlecblageaubesoin.Inspecteretresserrertouslesrac-cordstanches.4.Ouvrirtouslesrobinetsdestuyauteriesd'aspirationetderetour.5.Enlevertouslesbouchonsposspourl'hiver.6.Vidangertouslesproduitschimiquesd'hivrisation(lecaschant)dusystme;
rincerlesystme.7.Fermertouslesrobinetsdevidangeetreposertouslesbouchonsdevidangedu
systme(voirlapage10).8.Fairelepleindelapiscinejusqu'aubonniveau(sereporterauxinstructionsdu
fabricantdelapiscine).
ENTRETIENDESVANNESORIFICESMULTIPLES
Pressiondangereuse.Arrterlapompeetdissipertoutelapres-siondusystmeavantd'intervenirsurlefiltre,lavanneoulecollier.Laconcep-tiondufiltreetdelavannepermetlairdtreautomatiquementpurgenservicenormal.Toutefois,toujourssassurerquelapressionatdissipedusystmeavantdintervenirsurlefiltre,surlavanneousurlecollier.NOTA:Silavanneorificesmultiplesestplusbassequeleniveaudel'eaudelapiscine,fermerlesrobinetsdestuyauteriesd'aspirationetderetouravantdeprocderaudmontageafind'empcherquelapiscinesevide.
Remplacementdelapoigne: 1.Arrterlapompe.2.MettrelapoignedelavannesurlapositionFILTER.3.Dposerlagoupilled'immobilisation(Rf.1,Figures12Aet12B)pourdsoli-
dariserlapoigne.Silagoupillenepeutpastreenlevelamain,utiliserunmarteauetunpointeauetlachasserentapantlgrementdessus.4.Dposerlapoigne.Laremplacerparuneneuve.S'assurerquelapoigneest
danslapositionFILTER.5.Reposerlagoupilled'immobilisation.
Remplacementducouvercleetdubouchon:1.Dposerlapoigne(voirRemplacementdelapoigneci-dessus).2.Dposerlebouchon:
A.Dbouchertouteslesvisettouslescrous(Rf.nos2et6,Figures12Aet12B).
B.Dposerlecouvercle(Rf.3)entirantdroitdessustoutenimmobilisantl'axedubouchon(Rf.5)aveclepouce.
3.Inspectiondespicesinternes:Inspecterlebouchonetleressortdejoint,lesjointstoriquesetlesrondellesin-ternes(Rf.4).Lesremplacerselonlebesoin.
RECIRCULATE
BACKW
ASH
CLO
SED
WINTERIZE
WA
STE
FILT
ERRINSE
1
1A
2
3
4
5
6
Aquatools.WATERFORD,WI.
53185USA
7440294
Fig.12A:Dmontagedelavanne.(Vanneorificesmultiples,1-1/2po)
Fig.12B:Dmontagedelavanne.(Vanneorificesmultiples,2po)
13441094
1
1A
2
3
5
6
4
7/25/2019 Sta Rite CristalFloOM
25/32
8
ENTRETIEN
Gnralits:Laverl'extrieurdufiltreavecundtergentdouxetdel'eau.Lerinceravecun
tuyaud'arrosage.NOTA:NEPASutiliserdedissolvantspournettoyerlefiltre,carilsrisquentd'en-dommagerleslmentsenplastiquedusystme.Inspecterlelitdesableaumoinsunefoisparannepourenleverlescorps
trangersquin'ontpastchasssparleslavagescontre-courant.NOTA:Lorsquelelitdesabledevientdurousiledessusformecrote,viderle vieuxsabledurservoiretleremplacerpardusableneuf.
Inspectionhebdomadairedel'quipementdelapiscine:1.Vrifierlapressiondusystmependantsonfonctionnement.Dsquelapression
estsuprieurede34,548Kpa(57lb/po2)lapressiondemiseenservice
initiale,lavercontre-courant(voirlesInstructionssousMiseenservice/fonc-tionnementlapage7).2.Saufpartempschaudslorsquelapiscineestintensivementutilise,fairefonc-
tionnerlefiltrede612heuresparjourdevraittresuffisant.Surveilleratten-tivementl'quilibrechimiquedanslapiscineetsuivrelesrecommandationsd'unprofessionnellocalenmatiredepiscines.
Entretiendel'eauGarderleniveaudel'eau2pouces(51mm)aumoinsau-dessusdelapartie
infrieuredelcumoire.Lairpeutpntrerdanslesystmeetlefiltreetlapompepeutsedsamorcersilonnerespectepascetterecommandation.MaintenirlepHdelapiscineentre7,2et7,6.
Pournepasendommagerleslmentsdusystme,toujoursgarderlatem-praturedel'eauinfrieure35C(95F).
Passagedel'aspirateurdanslapiscine:1.Remplirletuyausoupledel'aspirateurenl'immergeantcompltementdansl'eau.2.Pourpasserl'aspirateur,introduireletuyaudanslecollecteurd'aspirationde
l'cumoireoudanslaconduited'aspirationquidbouchedanslaparoidelapiscine.Sereporterauxinstructionsfourniesparleconstructeurdelapiscineoulefabricantdelapiscine.Dmarrerlapompe,s'assurerqu'elleestamorceetqu'ellepompe.3.Aprsavoirpassl'aspirateur,nettoyerlacrpinedelapompepourenlevertous
lesdbrisquis'ysontaccumuls,puisvrifierlemanomtredufiltre.Aprsavoirlavlefiltrecontre-courant,ildoitindiquerunepressionvariantentre34,5et48Kpa(57lb/po
2)suprieurelapressiondemiseenserviceinitiale.
Pourabaisserleniveaudel'eaudanslapiscineoupourviderlapiscine1.ARRTERlapompe;rglerlapoignedelavannesurWASTE.2.Utiliserletuyausoupledel'aspirateuretlatte.3.Dmarrerlapompe;fairefonctionnerlapompejusqu'cequeleniveaud'eau
dsirdanslapiscinesoitatteint.4.ARRTERlapompe;rglerlapoignedelavannesurFILTER.5.Dmarrerlapompe.
ENTREPOSAGEETPRPARATIONPOURL'HIVER
Lesproduitschimiquesutiliserdanslespiscinesdgagentdesvapeurscorrosives.Lesentreposerloindusystmedansunendroitbienar.
NOTA:Silefiltregle,ilseraendommagetlagarantieseraannule.Sil'onutilisedel'antigel,utiliserdupropylne-glycol;ceproduitestcompatibleaveclesplastiquesetilestnontoxique.Suivrelesinstructionsdufabricant.Nepasutiliser
RECIRC
UL
ATE
BAC
KWAS
H CLOSED
WIN
TERIZE
WA
STEFILTE
R
RIN
SE
REC
IRCU
LATE
BACKWASH C
LOSED
WIN
TERIZE
WAST
E
FILTER
RIN
SE
Fig.10:Rglagesdelavannepourabaisserleniveaudel'eaudanslapiscine.Arrterlapompeavantdechangerlapo-sitiondelavanne.
REC
I
RCU
LATE
BACKWA
SH CLOSED
WIN
TERIZE
WASTE
FILTER
RIN
SE
Fig.11:Rglagedelavannepourl'entreposaged'hiver.Arrterlapompeavantdechangerlapositiondelavanne.
7/25/2019 Sta Rite CristalFloOM
26/32
7
Miseenservice/fonctionnement(VoirlaFigure9)
Pressiondangereuse.Pourviteruneexplosionetdesblessuresgravespossible,voiremortelles,lapressiondusystmedefiltrationnedoitjamaisdpasser345Kpa(50lb/pi
2).NEJAMAIScontrlercesystme
defiltrationl'aircomprim;nejamaisfairefonctionnerlesystmesilatempraturedel'eauestsuprieure35C(95F).
Pourempcherquel'quipementsoitendommagettoutesblessurespossibles,ARRTERlapompeavantdechangerlapositiondelavanne. NOTA:
Nejamaisajouterdeproduitschimiquesdirectementdansl'cumoire
delapiscine.L'ajoutdeproduitschimiquesnondilusrisqued'endommagerl'quipementetd'annulerlagarantie.
1.Ouvrirlesrobinetsdusystmeets'assurerquelapompeestpleined'eau.Ouvrirlesvannesdusystmeetsassurerquelapompeestpleinedeau.Sassurerqueleniveaudeleaudelapiscinearrive2pouces(51mm)au-dessusdelapartieinfrieuredelouverturedelcumoire.2.LapompetantARRTE,rglerlavannesurlapositionBACKWASH.3.Dmarrerlapompe;l'eaucirculeracontre-courantdanslefiltreetsera
envoyelol'ondsireendisposer.Nepasposerlemanomtretantquunjetcontinudeaunesortpasparlorificeprvupourlaposedumanomtre.Dsqueleausortparcetorifice,arrterlapompepuisposerlemanomtre.
NOTA:Pourempcherquelapompefonctionnesec,sassurerqueleniveaudeleaunechutejamaissouslapartieinfrieuredeladmissionde lcumoire.Aubesoin,ajouterdeleaudanslapiscinepourgarder
lcumoirepleindeaupendantquelonprocdeaulavagecontre-courantetaurinage.4.Procderaulavagecontre-courantdufiltrejusqu'cequel'eaucoule
claire(35minutes).5.Arrterlapompe;rglerlavannesurlapositionRINSE.6.Dmarrerlapompe;lafairefonctionnerpendantuneminute.7.Arrterlapompe;rglerlavannesurlapositonFILTER.8.Lefiltreestmaintenantprttreremisenservice.9.Releverlapressiondedmarragedufiltrepropreindiqueparle
manomtre(elleserviraderfrenceultrieure).10.Lorsquel'onremplitlapiscinepourlapremirefois,laverlefiltrecon-
tre-courantunefoisparjourjusqu'cequel'eaudelapiscinesoittrspropre.Aprscela,laverlefiltrecontre-courantlorsquelemanomtreindiqueunepressionde34,548Kpa(57lb/po2)suprieurelapres-
siondelamiseenserviceinitiale.
RECIRCU
LATE
BACKW
ASH
E
WASTE
FILTER
.InstallO-Ringonvalveflange.
Installvalveontank.Tankflangemustbeclean;insertcollectorpipeintobottomofvalve.
Delavan,WI.53115USA
1/4"Max.
Portlabeled"PUMP"shouldpointtowardpump.
Installclampandtightenuntilclampends(underbolt)are1/4"apart.
Ifunabletoclosegapto1/4"orless,
wait15-30minutesandretighten.
Taparoundclampwhiletighteningtohelpseatclamp.
.WATERFORD,WI.53185USA
7360294
RECIRCU
LATE
BAC
KW
ASH
E
WAST
E
FILTER
Fig.6
Fig.7
REC
IRCU
LATE
BACKWA
SH CLOSED
WIN
TERIZ
E
WAST
E
FILTER
RIN
SE
ValveSettingPurpose/Flow
FILTER
Normalfiltrationand
vacuuming;watergoes
throughfiltertopool.
RINSEForinitialstartupcleaning
andsandbedleveling
afterbackwash;watergothroughfiltertowaste.
RECIRCULATECirculatespoolwater;
bypassesfilter.
RECIRCULATE
BAC
KWASH CL
OSED
WIN
TERIZE
WAS
TE
FILTER
RINS
E
REC
IRCULATE
BACKWASH
CLOSED
WI
NT ERIZE
WASTE
FILTER
RIN
SE
737
BACKWASHReversesflowfor
cleaning;water
goesthroughfilter
towaste.
CLOSEDShutsoffallflowto
filterandpool.
WINTERIZELeavesallvalveports
partiallyopenfor
winterstorage.
REC
IR
CULATE
BACK
WASHCLO
SED
WI N
T ERIZE
WASTE
FILTER
RINSE
ValveSettingPurpose/Flow
RECIRC
UL
ATE
BAC
KWASH CLOSE
D
WI NTERIZE
WASTE
FILTER
RIN
SE
REC
IRC ULATE
BACKW
ASH CLOSED
WIN
TERIZE
WASTE
FILTER
RINSE
738029Fig.8
Taperlgrementtoutautourducollierpen-dantqueleserrepourl'aiderbienreposer.
Poserlecollieretleserrerjusqu'ce
quesesextrmits(souslavis)soient1/4depol'unedel'autre
BACKWASHDbitinversepourlenettoyage;l'eautraverselefiltre,puisrevientdanslapiscine.
CLOSEDLacirculationdel'eauverslefiltreetlapiscineestcompltementar-rte.
WINTERIZETouslesorificesdelavannesontpartiellementouvertspourlavidangeavantl'hiver.
RglagesdelavanneBut/dbitRglagesdelavanneBut/dbit
1/4depomax.
WASTELowerspoollevelor
drainspool;water
bypassesfilter,
goestowaste.
ValveSettingPurpose/Flow
RECIRC
ULAT
E
BACKW
ASH
CLOSED
WIN
TERIZE
WA
STEFILTE
R
RIN
SE
7430294
REC
IRCULATE
BAC
KWASH
CLOSED
WI NT ERIZE
WASTE
FILTER
RIN
SE
RECIRCULATE
BAC
KWASH CLOSED
WIN
TERIZE
WAS
TE
FILTER
RINS
E
REC
IRCU
LATE
BACKWA
SH CLOSED
WIN
TERIZE
WAST
E
FILTER
RINSE
Fig.9:Rglagesdelavannepourledmar-rage.Arrterlapompeavantdechangerlapositiondelavanne.
WASTEPourabaisserleniveaudel'eaudanslapiscineoupourviderl'eaudelapiscine;l'eauvitelefiltreetestenvoyel'gout.
RglagesdelavanneBut/dbit
FILTEROprationsnormalesdefil-trationetdepassagedel'aspirateur;l'eautraverselefiltre,puisretournedanslapiscine.
RINSEPourlamiseenserviceini-tiale,pourlenettoyageetlamisedeniveaudulitdesableaprsunlavagecontre-courant;l'eautra-verselefiltreavantd'treenvoyel'gout.
RECIRCULATEFaitcirculerl'eaudelapiscine;lefiltreestvit.
1.Poserlejointtoriquesurlabridedelavanne.
2.Poserlavannesurlerservoir.Labridedurservoirdoittrepropre.Introduireletuyaudela
conduitecentraledanslapartieinfrieuredelavanne.
L'orificeportantlamentionPUMPdoittreorientverslapompe.
Sil'onnepeutpasrapprocherlesextrmitsducollierjusqu'cequ'ellessoientau
moins1/4depol'unedel'autre,attendre1530min-
utesavantdecontinuerser-rerlecollier.
7/25/2019 Sta Rite CristalFloOM
27/32
6
Eauuse:S'assurerquetouteslesdispositionsprisespourl'liminationdel'eauusese
conformentauxcodesnational,provinciauxoumunicipaux.Pendantl'opra-tiondelavagedufiltrecontre-courant,379litres(100gallons)d'eaudelapiscine,voireplus,serontlimins.Nepasenvoyerl'eauloellerisquedecauserdesinondationsoudesdommages.
MontagedufiltreAssemblage:VoirlesFigures25pourl'assemblagedufiltre.Chargementdusablefiltrant
1.Nepasverserdesabledanslaconduitecentrale;poserleprotecteurdesableenplastiquesurlaconduitecentraleavantdeverserlesabledanslefiltre(voirlaFigure5).2.Defaonsupporterlestubeslatrauxetpourempcherqu'ilssecassentpen-
dantlechargement,remplirlerservoirmoitid'eauavantdeviderlesabledanslefiltre.3.Verserlesabledanslerservoirdefiltration.Sereporterlapage4pourcon-
natrelebontypeetlabonnequantitdesableutiliser.NOTA:S'assurerquelasurfaced'tanchitdudessusdurservoirestdbar-rassedesableavantdeposerlavanneetlecollier.4.Avantdeposerlavanne,vrifierunedeuximefoissilabonnequantitde
sableabientcharge(voirlapage4).5.Dposerleprotecteurdechargementdesableenplastiqueetleconserverpour
laprochainefois.
Installationdelavanne:VoirlesFigures6,7et81.Poserlejointtoriquesurlabridedelavanne.S'assurerquelejointtoriqueest
propre,sec,qu'ilnecomportepasd'entaillesnidedchirures.2.S'assurerquelesbridesdurservoiretdelavannesontpropresetdbarrasses
desable;poserlavannesurledessusdurservoir.Letuyauverticaldelacon-duitecentrales'insredanslabasedelavanne.3.Poserlecollier;s'assurerqueleboutonducollierestpositionndefaonpou-
voiryaccderfacilementlorsdel'entretiendufiltre.L'orificedelavannepor-tantlamentionPUMPdoittreorientverslapompe.4.Serrerleboutonducollierjusqu'cequelesextrmitsducollier(souslavis)
soient6mm(1/4depo)l'unedel'autre.Al'aided'unemassetteencaoutchouc,tapertoutautourducollierpourluipermettredebienreposer.
Pressiondangereuse.Lecollierneresterapasenplaces'ilnereposepasbien!NEPASDMARRERLAPOMPEsilesextrmitsducolliernesontpas6mm(1/4depo)l'unedel'autre.5.Silecollierneseserrepasjusqu'cequesesextrmitssoient6mm(1/4de
po)l'unedel'autre,attendre1530minutes,puisleresserrer.l'aided'unemassetteencaoutchouc,taperlgrementsurlecollierpourl'aiderbienre-poser.6.Brancherletuyauvenantductretourdelapompesurl'orificedelavanne
portantlamentionPUMP;utiliserlamoitiduraccordunionfourni.Pourqu'iln'yaitpasdefuites,assemblerleraccordunionenprocdantcommesuit:A.Lessurfacesd'tanchitetlesjointstoriquesdoiventtrepropres.B.Neserrerleraccordqu'lamain(pasavecunecl).C.Aucunepted'tanchitpourraccordsfiletsnirubanTflonnedoittre
utilissurlesraccordsunions.7.Terminertouslesraccordsdelaplomberie(serapporterlapage5pourles
tuyauteries).A.Letuyaudel'orificeRETOUR(RETURN)delavannedoittreorientversle retourdelapiscine.
B.Letuyauvenantdel'orificeEAUUSE(WASTE)delavannedoittreorientverslectol'eauuseseraenvoye.C.Letuyaud'aspirationprovenantdelapompedoittreorientverslect
arrivedelacrpinedelapompe.8.Lesystmeestmaintenantprttremisenservice.
NOTA:Sil'onremarquedesfuitessouslapartievanne/collier,ARRTERLAPOMPE,dissipertoutelapressiondanslesystme,dposerlecollieretlavanneetnettoyerleurssurfacesd'tanchit.
B.Insertassemblyintotopoffiltertank.
A.Insertfirstlateralintosocket;twistclockwise1/4turntolocklateralintohub.Lateraliscorrectlyinstalledwhenslotsfacedown.
7310294
C.Holdassemblyup
neartopoftankand
addremaining
laterals.
7320294
D.Afterall
lateralsare
securelyin
sockets,
position
assemblyon
centering
bossin
bottomof
tank.
7330294
SAND
:::: :::: :::::::: :::: ::::
:::: :::: :::::::: :::: ::::
:::: :::: :::::::: :::: ::::
::
::
::::
:::
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:::
::::
::::
:
:::
::
::
::
::
::::
::::
::::
::::
::::
::::
::
::
:::
:
:::
:
:
:::
::
::
::
::
::::
::::
::::
:
:
:
:
:
:
:
:
::
:
:
:
:
::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
::::
::::
::::
::::
::::
::::
::::
::::
::::
:
:
:
:
:
:
:
:
:
:
:
:
:::: :::: :::::::: :::: ::::
:::: :::: :::::
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
: ::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::::::
::::
::::
::::
::::
:::::
:::
::::
:::::
:::
::::
::::
::::
::::
::::
::::
::::
:::::
:::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
::::
Filltankabouthalffullofwaterbefore adding
sand.
SandShieldkeepscollectorhubassemblycleanwhenloadingfilter.
7340294
Fig.2
Fig.3
Fig.4
Fig.5
A.Introduirelepremiertubelatraldansladouille:letournerdroitede1/4detourpourleverrouillerdansleraccord.Letubelatralestbienposlorsquesesfentessont
orientesverslebas.
B.Introduirel'ensem-bleparlehautdufiltredurservoir.
C.Tenirl'ensembleprsduhautdurservoiretposerlesautres
tubes
D.Aprsquetouslestubeslatrauxsontretenusentoutescuritdanslesdouilles,positionnerl'ensemblesurle
bossagedecentragepratiqudanslefonddurservoir.
Leprotecteurdesableviteradeverserdusablesurleraccorddelaconduitecentralepen-dantlechargementdufiltre.
Remplirlerservoir
moitid'eauavantd'yajouterlesable.
SABLE
7/25/2019 Sta Rite CristalFloOM
28/32
5
RENSEIGNEMENTSGNRAUXSilapiscineestneuve,lanettoyerlemieuxpossibleavantdelarempliretdefaire
fonctionnerlefiltre.Lefiltreetlapomperisquentd'tresrieusementendommagssilesystmecontienttropdesaletsetdegrossesparticulesdecorpstrangers.
NEJAMAIScontrlercefiltrel'aircomprim.
Nepasfairefonctionnerlefiltresilatempraturedel'eauestsuprieure35C(95F).
NEJAMAISfairefonctionnercesystmedefiltrationpardespressionssuprieures50lb/po2(345Kpa)!
INSTALLATIONL'installationdufiltrenedoittreeffectuequepardupersonnelqualifi.Pourcon-natrelesinstructionsd'assemblageetderemplissage,sereporterlapage6.
L'assisedufiltredoit:assureruneprotectioncontrelegeletlesintempries;assurersuffisammentd'espaceetd'clairagepourunaccsfacilelorsdesentretiens
priodiques.(VoirlaFigures1et2etleTableau2lapage4pourlesdgagementsexigs.)reposersurunesurfaceraisonnablementdeniveauetassurerundrainageadquat;treaussiprsquepossibledelapiscinepourrduirelespertesparfrictiondansles
tuyauteries.Tuyauteries:
Ellesdoiventseconformerauxcodessanitairesetdelaplomberiedelaprovinceet/oudelamunicipalit.Utiliserdelapted'tanchitpourraccordsfiletsoudurubanTflonsurlesrac-
cordementsmlesdestuyauxetdesraccordsmlesmtalliques(l'exceptiondesrac-cordsunions).UtiliserdurubanTflonouduPlasto-JointStik
1surtousles
raccordementsmlesdesraccordsetlestuyauxenplastique.NEPASutiliserdeptepourraccordsfiletssurlestuyauxenplastique,sinonlestuyauxsefissureront.Nepasutiliserdepted'tanchitpourraccordsfiletsniderubansurlesraccordsunions-lesassemblersecetnelesserrerqu'lamain.Nepasendommagerlessurfacesd'tanchitdesraccordsunionsnilesjoints
toriques.Supporterchaquetuyauteriedefaonempchertoutecontraintesurlefiltreousurla
vanne.Utiliserdestuyauxde1-1/2pooude2popourminimiserautantquepossibleles pertesdepression.
NOTA:Lefiltrepeuttreplacloindelapiscine.Danscecas,toutefois,etpouras-surerundbitadquat,destuyauxdeplusgrosdiamtredoiventtreutiliss.tudierlescodesmunicipauxlorsquel'onconsidreuneinstallationdistance.Lesraccordsdiminuentledbit;pourunemeilleureefficacit,utiliserlemoinspossi-
blederaccords.Lestuyauxdoiventtretoujoursbienserrsetnepasfuir:unefuitedelaconduite
d'aspirationdelapomperisqued'emprisonnerdel'airdanslerservoirdefiltrationoudedsamorcerlapompe;onremarqueraunefuitedelaconduitederetourdelapompepardel'humiditoudesjetsd'eau.Lorsquedesraccordsunionssontfournis,etpourobtenirdesraccordementsquine
fuientpas,lesutilisercommesuit:1.Lessurfacesd'tanchitetlesjointstoriquesdoiventtrepropres.2.Lesraccordsnedoiventtreserrsqu'lamain(pasavecunecl).3.Aucunepted'tanchitpourraccordsfiletsnirubanTflonnedoittreutilissur
lesraccordsunions.
Clapets:Unclapetantiretourposentrelefiltreetlechauffe-eauempcheral'eauderetourner
danslefiltreetdecauserladformationdeslmentsinternes.Ilfauttretrsprudentavantdeprocderl'assemblageafindenepasendommager
lessurfacesd'tanchitdesraccordsunionsnilesjointstoriques.
1LakeChemicalCo.,Chicago,IL
7/25/2019 Sta Rite CristalFloOM
29/32
4
Sereporterlapage14pourlacourbedechutedepression.
CALIBRESDUSABLERECOMMAND:N'utiliserquedusabledesilicen20,calibre-4055mm.Coefficientd'unifor-mitinfrieur1,75.NOTA:L'utilisationd'unautresablerduiralerendementdufiltre,risquerad'en-dommagerlapompeetannuleralagarantie.
Matriauxfiltrantsrecommands:1.WedronSilica/BestSandCo.,calibredusable:Wedron-4555mm; calibreutile:0,46mm;coefficientd'uniformit:1,22.
2.U.S.Silica:Sabledefiltrationsilurien,calibredusable:4555mm;calibreutile:0,48mm;coefficientd'uniformit:1,18.
DebitmaximumModleEncombrementengal/mindefiltredufiltre(L/min)
DiamtreenSurfaceenpiedspouces(mm)carrs(m
2)
T-150BP-115(381)1.26(.117)25.2(95)T-170BP-117(432)1.57(.146)31.5(123)T-200BP-120(508)2.18(.203)43.6(165)T-240BP-124(610)3.10(.288)62.0(234.7)T-240BP-224(610)3.10(.288)62.0(234.7)T-300BP-230(762)4.90(.455)98(371)
RenouvellementenheuresVolumeduModlesableendefiltre681012livres(kg)
gal.(L)gal.(L)gal.(L)gal.(L)T-150BP-19,070(34330)12,100(45799)15,120(57229)18,144(68675)100(45.4)
T-170BP-111,340(42922)15,120(57229)18,900(71536)22,680(85844)150(68)
T-200BP-115,700(59424)20,930(79220)26,160(99016)31,390(118811)200(90.7)
T-240BP-122,230(84481)29,760(112642)37,200(140802)44,640(168962)300(136)
T-240BP-222,230(84481)29,760(112642)37,200(140802)44,640(168962)300(136)
T-300BP-235,280(133535)47,040(178046)58,800(222558)70,560(267070)600(272)
LargeurLongeurDimensionsdusocledusocledelorificede
ModledefiltreABCD(E)(F)latuyauterie
T-150BP-127(686)33-13/16(859)15-3/4(400)24-11/16(627)13(330)16-1/4(413)1-1/2SLIPT-170BP-129-9/16(751)36-3/8(924)17-3/4(451)27-1/4(692)13(330)16-1/4(413)1-1/2SLIPT-200BP-131-5/8(803)38-1/2(978)20-3/4(527)29-3/8(746)13(330)16-1/4(413)1-1/2SLIPT-240BP-135-3/16(897)42(1067)24-3/4(629)32-7/8(835)16-7/8(429)21(533)1-1/2SLIPT-240BP-235-1/4(895)44-1/2(1130)24-3/4(629)32-7/8(835)16-7/8(429)21(533)2(NPT)T-300BP-242(1067)51-1/4(1302)31(787)39-5/8(1008)16-7/8(429)21(533)2(NPT)
TABLEAUIINFORMATIONSCONCERNANTLEFONCTIONNEMENTDUFILTRE
TABLEAUII-DIMENSIONSEXTRIEURESENPOUCES(mm)
*NOTA:1piedcube(28320cm3)desablepseenviron45,4kg(100lb).NEPASutiliserdesable
decalibreplusfinqueceluirecommand.
CDia.B
AD
2.88(73)
PumpInlet1-1/2"
WasteOutlet1-1/2"Unionconnection
ReturnOutlet1-1/2"Slip
E,F13551094
C
D
A
B
9.25(235)
2"NPTOutlet(Waste)
2"NPTInlet(Pump)
2"NPTOutlet(Return)
E,F
8.00(203)13561094
Fig.1:Dimensions,T-150BP-1T-170BP-1,T-200BP-1,T240BP-1
Fig.2:Dimensions,T-300BP-2,T240BP-2
SortieeauuseRaccordunionde1-1/2pouce missiondeaudela
mpede1-1/2pouce
ederetourde pouce,glisser
Sortiede2poucesNPT(eauuse)
Admissionde2
Sortiede2pouces
NPT(retour)
7/25/2019 Sta Rite CristalFloOM
30/32
3
Unquipementmalinstalloumalcontrlpeuttomberenpanne,causerdegravesblessuresoudesdommagesmatriels.LireetsuivrelesinstructionsfigurantdanslaNoticedel'utilisateurpourinstalleretutiliserl'quipement.Demanderunepersonne
connaissantbienlespiscinesdeprocderauxcontrlesdelapression.
1.Nepasbrancherlesystmesurunepressionleveousurl'eaudelaville.
2.N'utiliserl'quipementqu'avecunepiscineouunecuveremous.3.Del'airemprisonndanslesystmerisquedecauseruneexplosion.
S'ASSURERquetoutl'airestchassdusystmeavantdefairefonctionnerl'quipementoudelecontrler.
Avantdeprocderuncontrledepression,procderauxvrificationsdescuritsuivantes:
Vrifiertouslescolliers,couvercles,accessoiresettouteslesvisdusystme.
S'ASSURERquetoutl'airestpurgdusystme.
ResserrerlecouvercledelacrpinedespompesSta-Riteaucouplede4,1kg-cm(30lb-pi).
Lapressiondel'eaudoittreinfrieure172Kpa(25lb/po2).
Latempraturedel'eaudoittreinfrieure35C(95F).
Limiterlecontrle24heures.Aprsavoirprocdaucontrle,examinervisuellementlesystmepours'assurerqu'ilestprttreutilis.Dposerlecouvercledelacrpineetneleresserrerqu'lamain.
NOTA:Cesparamtresnes'appliquentqu'del'quipementSta-Rite.Pourunquipementd'uneautremarquequedemarqueSta-Rite,consulterlefabricant.
Pressiondangereuse!
Risquedegravesblessuresoudedom-magesmatrielsimpor-tantsencasd'explosiondurservoir.
AVANTD'INTERVENIRSURLEFILTRE:
1.Arrterlapompe.
2.Ouvrirlasoupapededissipationd'air.
3.Dissipertoutelapres-siondanslesystme.
Lespompesdesfiltresfonctionnentsurdesten-sionsdangereusesquirisquentdecauserdeschocslectriques,desbrlures,voirelamort.
AVANTD'INTERVENIRSURLA
POMPEOUSURLEMOTEUR
Interromprelecourantlectriqueparvenantaumoteur.
AVERTISSEMENT
7/25/2019 Sta Rite CristalFloOM
31/32
2
FILTRESSABLEDBITLEV
Pourviterlesappelsinutilesd'unrparateur,vitertoutesblessurespossiblesetobtenirleplusderendementdecefiltre,LIREATTENTIVEMENTCETTENOTICE!LefiltresablegranddbitSta-Ritevannemontesurledessus:estconupourfiltrerl'eaudespiscines.estunappareilexcellent,durableetfiable.
TabledesmatiresConsignesdescurit.......................................................................................2-3
Dimensions/spcifications....................................................................................4
Renseignementsgnraux....................................................................................5
Installation.......................................................................................................5-7
L'assisedufiltre/tuyauteries.............................................................................5
Montagedufiltre.............................................................................................6
Installationdelavanne........................................................................................6
Miseenservice/fonctionnement......................................................................7
Entretien..............................................................................................................8
Entretiendel'eau............................................................................................8Entreposageetprparationpourl'hiver...........................................................8-10
Remiseenservicedel'quipementaprsl'hiver..............................................9
Dpose/reposeduraccorddevidange...........................................................10
Guidedediagnosticdespannes.........................................................................11
Listedespicesderechange.........................................................................12-13
Courbedechutedepression...............................................................................14
Garantie............................................................................................................15
LIREETOBSERVERCES
CONSIGNESDESCURIT!Cesymboleindiquequ'ilfauttreprudent.Lorsquecesymboleapparatsur
lesystmeoudanscetteNotice,rechercherunedesmisesengardequisuivent,carellesindiquentunpotentielpossibledeblessurescorporelles.
avertitd'undangerquicauseradesblessurescorporelles,lamortoudesdommagesmatrielsimportantssionl'ignore.
avertitd'undangerquirisquedecauserdesblessurescorporelles,lamortoudesdommagesmatrielsimportantssionl'ignore.
avertitd'undangerquicauseraouquirisqueradecauserdesblessurescorporelles,lamortoudesdommagesmatrielsimportantssionl'ignore.LemotNOTAindiquedesinstructionsspcialesetimportantesn'ayantaucun
rapportaveclesdangers.
LireattentivementtouteslesconsignesdescuritcontenuesdanscetteNoticeetfigurantsurlefiltreetlesrespecter.
Toujoursgardercesautocollantsdescuritenbontat.
Remplacertouslesautrescollantsdescuritmanquantsouendommags.
7/25/2019 Sta Rite CristalFloOM
32/32
FILTRESSABLEGRANDDBITCRISTAL-FLOTM
NOTICEDUTILISATION
POSE,FONCTIONNEMENTETPICES
MODLEST-150BP-1T-170BP-1T-200BP-1T-240BP-1T-300BP-2
Sta-RitePool/SpaGroup
293WrightStreet,Delavan,WI53115
International:262-728-5551,FAX:262-728-7550
www.starite.com
UnionCity,TNDelavan,WIMississauga,ON
2005,Sta-RiteIndustriesS242(Rv.2/12/05)
CetteNoticedoittreremisel'utilisa-teurdecefiltre;elleservirarduirelesappelsdedpannageetlespossibil-itsdeblessures,demmequ'pro-longerladuredufiltre.
RECIRCULATE
BAC
KWA
SH
E
WASTE
FILTER
Aquatools.WATERFORD,WI.
53185USA
7290294
PentairPoolProducts,Inc.1620HawkinsAve.
Sanford,NC27330
Tel919-774-4151Fax919-774-4841
S242(Rev.B6/28/06)