CAT.EUS50-24 -UKB
Male connector Male elbow
Seal parts(Special FKM)
Seal parts(Special FKM)
Material
Metal parts: Stainless steel 316Seal parts: Special FKMCan be used with steam
Operating fluid temperature
–5 to 150°CGrease-free
Applicable tubing material
• FEP, PFA, Nylon, Soft nylon, Polyurethane
• Polyolefin
All stainless steel 316 (except seal parts)
Series KQG
Stainless Steel 316One-touch Fittings
• Certified to meet current Food Sanitation Law standards. Component materials have met apparatuses and container-packages standards, based on Directive 85 of the Japanese Ministry of Health and Safety in 1986.
Applicable tubingO.D. (mm)
Connectionthread Model
M5
R1/8
M5
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R3/8
R1/2
KQGH04-M5KQGH04-01SKQGH06-M5KQGH06-01SKQGH06-02SKQGH08-01SKQGH08-02SKQGH08-03SKQGH10-02SKQGH10-03SKQGH12-03SKQGH12-04S
ø4
ø6
ø8
ø10
ø12
Applicable tubingO.D. (mm)
Connectionthread Model
M5
R1/8
M5
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R3/8
R1/2
KQGT04-M5KQGT04-01SKQGT06-M5KQGT06-01SKQGT06-02SKQGT08-01SKQGT08-02SKQGT08-03SKQGT10-02SKQGT10-03SKQGT12-03SKQGT12-04S
ø4
ø6
ø8
ø10
ø12
Male Branch Tee
Applicable tubing O.D. (mm) Model
KQGH04-00KQGH06-00KQGH08-00KQGH10-00KQGH12-00
Straight Union
ø4ø6ø8
ø10ø12
Applicable tubing O.D. (mm) Model
KQGT04-00KQGT06-00KQGT08-00KQGT10-00KQGT12-00
Union Tee
ø4ø6ø8
ø10ø12
Applicable tubing O.D. (mm) Model
KQGU04-00KQGU06-00KQGU08-00KQGU10-00KQGU12-00
Union “Y”
ø4ø6ø8
ø10ø12
Applicable tubingO.D. (mm)
Connectionthread Model
M5
R1/8
M5
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R3/8
R1/2
KQGL04-M5KQGL04-01SKQGL06-M5KQGL06-01SKQGL06-02SKQGL08-01SKQGL08-02SKQGL08-03SKQGL10-02SKQGL10-03SKQGL12-03SKQGL12-04S
ø4
ø6
ø8
ø10
ø12
Male Elbow
Applicable tubingO.D. (mm)
Connectionthread Model
M5
R1/8
M5
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R3/8
R1/2
KQGS04-M5KQGS04-01SKQGS06-M5KQGS06-01SKQGS06-02SKQGS08-01SKQGS08-02SKQGS08-03SKQGS10-02SKQGS10-03SKQGS12-03SKQGS12-04S
ø4
ø6
ø8
ø10
ø12
Haxagon Socket Head Male Connector
Applicable tubing O.D. (mm) Model
KQGL04-00KQGL06-00KQGL08-00KQGL10-00KQGL12-00
Union Elbow
ø4ø6ø8
ø10ø12
Applicable tubing O.D. (mm) Model
KQGE04-00KQGE06-00KQGE08-00KQGE10-00KQGE12-00
Bulkhead Union
ø4ø6ø8
ø10ø12
Male Connector
Male Branch Tee
Straight Union
Union Tee
Union “Y”
Male Elbow
Hexagon Socket Head Male Connector
Union Elbow
Bulkhead Union
Male Connector
Features 1
1
Stainless Steel 316One-touch Fittings
Series KQGApplicable Tubing
Tubing material
Tubing O.D.
FEP, PFA, Nylon, Soft nylon, Polyurethane Note 3), Polyolefin
ø4, ø6, ø8, ø10, ø12
Specifications
Operating fluid
Operating pressure range Note 1)
Proof pressure
Ambient and Operating fluid temperature Note 2)
Lubricant
Seal on the threads
Air, Water, Steam Note 4)
–100 kPa to 1MPa
3.0 MPa
–5 to 150°C (No freezing)
Grease-free specification
With sealant
Tube size
040204250403060408050806106510751008120812091210
TJ-0402TJ-0425TJ-0403TJ-0604TJ-0805TJ-0806TJ-1065TJ-1075
TJ-1208
TJ-1209TJ-1210
Tubing model (Material)
TU(Polyurethane)
—
—
—
—
—
—
—
TUS(Soft polyurethane)
—
—
—
—
—
—
—
TH(FEP)
—
—
—
—
TL(PFA)
—
—
—
—
—
—
—
Applicable inner sleeve
Model
18
18
18
19
20.5
20.5
23
23
24
24
24
Length
Note 1) Please avoid using in a vacuum holding application such as a leak tester, since there is leakage. Note 2) When using at 120°C or higher, for an extended period of time, we recommend that an inner sleeve be
used. Note 3) In the event of using polyurethane tubing, we recommend the use of an inner sleeve in cases where the
tubing is strained.Note 4) Special FKM that is resistant even when steam is used.
Construction
No.
123456789
DescriptionRelease bushingGuideChuckSealMale connector bodyMale elbow bodyO-ringStopper ringStud
Stainless steel 316Stainless steel 316Stainless steel 316
Special FKMStainless steel 316Stainless steel 316
Special FKMStainless steel 316Stainless steel 316
Material
q
yre w q
w
er
ui
o
t
Dimensions
2
Series KQG
Male Connector: KQGHApplicabletubing O.D.
(mm)
ConnectionthreadR
ø4
ø6
ø8
ø10
ø12
10
12
14
17
19
22
KQGH04-M5KQGH04-01SKQGH06-M5KQGH06-01SKQGH06-02SKQGH08-01SKQGH08-02SKQGH08-03SKQGH10-02SKQGH10-03SKQGH12-03SKQGH12-04S
M5
1/8
M5
1/8
1/4
1/8
1/4
3/8
1/4
3/8
3/8
1/2
ModelH
(width across flats)
10
12
14
17
19
øD L
22.3
24
24.1
24.3
25.8
30.5
28.5
24
35.5
31
32.8
19.3
20
21.1
20.3
19.8
26.5
22.5
17.7
29.5
24.7
26.5
24.6
7.4
9.4
11
11
18
18
18
24
29
29
31
51
A∗
18
18.8
20.9
23
24.8
M Weight(g)
4
5.6
4
10.4
26.1
41.5
58.3
Effectivearea Note 1)
(mm2)
∗ Reference dimensions after installation of R threadNote 1) Figures shown when using FEP tubing
Hexagon Socket Head Male Connector: KQGS
ø4
ø6
ø8
ø10
ø12
2
3
2
4
5
6
8
10
KQGS04-M5KQGS04-01SKQGS06-M5KQGS06-01SKQGS06-02SKQGS08-01SKQGS08-02SKQGS08-03SKQGS10-02SKQGS10-03SKQGS12-03SKQGS12-04S
M5
1/8
M5
1/8
1/4
1/8
1/4
3/8
1/4
3/8
3/8
1/2
10
12
14
17
19
22
øD L
25
25.8
30.5
28.5
30.1
35.5
31
32.8
22
21
22.8
21.8
19.8
26.5
22.5
23.8
29.5
24.7
26.5
24.6
8.6
9.8
12
12
20
17
18
35
28
29
30
54
A∗
18
18.8
20.9
23
24.8
M
4
4.1
4
9.9
10
17.2
23.3
39
60
∗ Reference dimensions after installation of R threadNote 1) Figures shown when using FEP tubing
Straight Union: KQGHApplicabletubing O.D.
(mm)
ø4ø6ø8ø10ø12
KQGH04-00KQGH06-00KQGH08-00KQGH10-00KQGH12-00
Model
Model
11
13
15
19
21
øD L
37
38
42.8
47
50.6
18
18.5
20.9
23
24.8
16
22
31
54
66
M
5.6
13.1
26.1
41.5
58.3
Effective area(mm2)
Note 1) Figures shown when using FEP tubing
Male Elbow: KQGL
ø4
ø6
ø8
ø10
ø12
10
14
12
14
17
22
KQGL04-M5KQGL04-01SKQGL06-M5KQGL06-01SKQGL06-02SKQGL08-01SKQGL08-02SKQGL08-03SKQGL10-02SKQGL10-03SKQGL12-03SKQGL12-04S
M5
1/8
M5
1/8
1/4
1/8
1/4
3/8
1/4
3/8
3/8
1/2
Model
10.6
13
15
18
20.8
øD L2
16
19.5
17
20.5
24.5
21.9
25.9
27.9
27.7
29.7
30.7
34.7
L1
20.5
22.1
24.9
27.8
31.3
18.3
20.8
20.5
23
25
25.4
27.4
29.1
30.7
32.4
35.1
37.2
18
20
25
26
35
37
45
56
69
73
94
121
A∗
18
18.8
20.9
23
24.8
3.5
4.2
3.5
9
21.6
35.2
50.2
M
∗ Reference dimensions after installation of R threadNote 1) Figures shown when using FEP tubing
(In case of M5)
(In case of R)
AL
øD
M
øD
A ML
(In case of M5)
Applicable tubing
H
Connection thread
(In case of R)
Applicable tubing
H
Connection thread(with seal)
L AAL
øD
M
øD
M
Applicable tubing
H
Connection thread
Applicable tubingH
Connection thread(with seal)
øD
ML
øD
M
2-applicable tubing
L2
A
L1
M
øD
L2
A
L1
M
øD
Applicable tubing
H
Connection thread(with seal)
Applicable tubing
(In case of M5)
HConnection thread
(In case of R)
Applicabletubing O.D.
(mm)
ConnectionthreadR
H(width
across flats)
Weight(g)
Weight(g)
Effectivearea Note 1)
(mm2)
Applicabletubing O.D.
(mm)
ConnectionthreadR
H(width
across flats)
Weight(g)
Effectivearea Note 1)
(mm2)
Note 1)
3
Series KQGStainless Steel 316One-touch Fittings
Dimensions
Union Elbow: KQGL
ø4ø6ø8ø10ø12
KQGL04-00KQGL06-00KQGL08-00KQGL10-00KQGL12-00
Model øD Weight(g)øNMQ2Q1AL
Note 1) Figures shown when using FEP tubing
10.6
13
15
18
20.8
20.6
22.4
25.5
28.6
31.4
27.3
28.9
35.1
38.2
41.8
21
32
49
76
108
2.3
3.5
5
6.4
3.7
3.5
5.6
6.4
18
18.8
20.9
23
24.8
3.2
4.2
4.2
9
21.6
35.2
50.2
Q2
A
Q1
L
L
M
øD
M
øD
øN
2-Applicable tubing
Bulkhead Union: KQGE
ø4ø6ø8ø10ø12
KQGE04-00KQGE06-00KQGE08-00KQGE10-00KQGE12-00
Model T(M)
Weight(g)MMounting
holeLH
(widthacross flats)
Note 1) Figures shown when using FEP tubing
M12X1
M14X1
M16X1
M20X1
M22X1
14
17
19
24
27
37
38
42.8
47
50.6
13
15
17
21
23
18
18.5
20.9
23
24.8
21
29
40
71
95
5.6
10.4
26.1
41.5
58.3
Mounting plate thickness7 mm or larger
ML
M
H T 2-applicable tubing
Union Tee: KQGT
ø4ø6ø8ø10ø12
KQGT04-00KQGT06-00KQGT08-00KQGT10-00KQGT12-00
Model Weight(g)øD
Note 1) Figures shown when using FEP tubing
10.6
13
15
18
20.8
L
20.6
22.4
25.5
28.6
31.4
A
28.7
31.4
36.3
40.6
44.5
Q
4.1
4.9
6.1
7.1
8.1
M
18
18.8
20.9
23
24.8
28
42
57
95
129
øN
3.2
4.2
6.4
10.6
25.6
40
57.4
QA
LM
øDL
L
M
øD
M
øD
øN
3-applicable tubing
Union “Y”: KQGU
ø4ø6ø8ø10ø12
KQGU04-00KQGU06-00KQGU08-00KQGU10-00KQGU12-00
Model Weight(g)øD
Note 1) Figures shown when using FEP tubing
10.6
13
15
18
20.8
W
21.2
26
30
36
41.6
L1
41
42.9
47.7
52.8
57.8
L2
16.8
17
18.7
20.5
21.9
P
10.6
13
15
18
21
M
18
18.8
20.9
23
24.8
øN
3.2
4.2
35
54
75
114
175
2.9
7.4
17.9
28
40.2
WP
L1
L2
M
øD
M
øN
3-applicable tubing
Male Branch Tee: KQGT
ø4
ø6
ø8
ø10
ø12
10
14
12
14
17
22
KQGT04-M5KQGT04-01SKQGT06-M5KQGT06-01SKQGT06-02SKQGT08-01SKQGT08-02SKQGT08-03SKQGT10-02SKQGT10-03SKQGT12-03SKQGT12-04S
M5
1/8
M5
1/8
1/4
1/8
1/4
3/8
1/4
3/8
3/8
1/2
Model
10.6
13
15
18
20.8
øD L2
18
21.5
19
22.5
26.5
23.9
27.9
29.9
29.7
31.7
32.7
36.7
L1
20.5
22.1
24.9
27.8
31.3
23.1
25.6
25
27.5
29.5
30.7
32.7
34.4
35.7
37.4
39.5
41.6
26
27
39
41
50
61
70
83
97
101
133
159
A∗
18
18.8
20.9
23
24.8
4.5
6
4.5
11
26.3
40.8
57.2
M Weight(g)
∗ Reference dimensions after installation of R threadNote 1) Figures shown when using FEP tubing
L1
M
L1
M
L2 A
L1
M
øD
L2
A
L1
M
øD
2-applicable tubing
HConnection thread(with seal)
2-applicable tubing
(In case of M5)
HConnection thread
(In case of R)
Applicabletubing O.D.
(mm)
Applicabletubing O.D.
(mm)
Applicabletubing O.D.
(mm)
Applicabletubing O.D.
(mm)
Applicabletubing O.D.
(mm)
ConnectionthreadR
Effectivearea Note 1)
(mm2)
Effectivearea Note 1)
(mm2)
Effectivearea Note 1)
(mm2)
Effectivearea Note 1)
(mm2)
Effectivearea Note 1)
(mm2)
H(width
across flats)
Series KQGApplicable Fluid Compatibility List
Compatibility Checklist for Used Materials and Fluids
Note 1) [ ] denotes the concentration. Aqueous solutions without condensation notes are in a saturated state.
Note 2) The above data is based on a room temperature of 20°C. Note that you may obtain different figures, depending on temperature conditions.
Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalogue are not covered by the product’s warranty.
How to Read the Table
: Completely unaffected or largely unaffected. : May be slightly affected, but, dependent upon the conditions, can sufficiently withstand. : Advisable to use as little as possible. : Not applicable, is substantially affected. : No data is available.
4
ChemicalMain body Seal
Special FKM
Acrylonitrile
Acetamide
Acetaldehyde
Acetone
Aniline
Amylene
Sulphurous acid gas (Humid gas)
Sodium bisulfite [50%]
Allyl alcohol
Benzoic acid
Ammonia (Compressed gas)
Isopropyl alcohol
Isophorone
Ethyl alcohol
Ethyl ether
Ethylene
Ethylene glycol
Ethylene diamine
Ethylene dichloride
Epichlorohydrine
Methyl tertiary butyl ether
Allyl chloride
Ammonium chloride
Calcium chloride
Iron chloride (II) [5%]
Sodium chloride
Magnesium chloride
Hydrochloric acid [5%]
Chlorine gas (Humid gas)
Carbitol
Formic acid [50%]
o-Xylene
p-Xylene
ChemicalMain body
Stainless steel316
Stainless steel316
Seal
Special FKM
Citric acid
Cumene
Glycerin
Cresol
Chromic acid [10%]
Chlorosulfonic acid
Chlorofluorocarbon (CFC) 11
Chlorofluorocarbon (CFC) 113
Chlorofluorocarbon (CFC) 12
Chlorofluorocarbon (CFC) 13B1
Chlorofluorocarbon (CFC) 14
Chlorofluorocarbon (CFC) 22
Chlorobenzene
Chloroform (Trichloromethane)
Acetic acid
Amyl acetate
Isopropyl acetate [20%]
Ethyl acetate
Butyl acetate
Methyl acetate
Calcium hypochlorite
Sodium hypochlorite [5%]
Potassium cyanide [50%]
Copper cyanide
Diisobutyl ketone
Diisobutylene
Diethanolamine
Diethylamine
Diethylene glycol
Carbon tetrachloride
Cyclohexanol
Cyclohexanone
Cyclohexane
Series KQGApplicable Fluid Compatibility List
Compatibility Checklist for Used Materials and Fluids
Note 1) [ ] denotes the concentration. Aqueous solutions without condensation notes are in a saturated state.
Note 2) The above data is based on a room temperature of 20°C. Note that you may obtain different figures, depending on temperature conditions.
Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalogue are not covered by the products warranty.
How to Read the Table
: Completely unaffected or largely unaffected. : May be slightly affected, but, dependent upon the conditions, can sufficiently withstand. : Advisable to use as little as possible. : Not applicable, is substantially affected. : No data is available.
5
Dichloroethylene
Dichlorobenzene
Dichloromethane (Methylene chloride)
Ethylene bromide
Potassium bromide [30%]
Potassium dichromate [25%]
Oxalic acid
Bromine gas
Tartaric acid
Nitric acid [65%]
Ammonium nitrate
Ammonium hydroxide
Calcium hydroxide
Sodium hydroxide [50%]
Barium hydroxide
Solvent naphtha
Tetrachloroethylene
Tetrahydrofuran
Dodecylbenzene
Trichloroethane
Trichloroethylene
Trichloroacetic acid
Toluene
Naphtha
Naphthenic acid
Lactic acid
Carbon disulfide
Picric acid
Pyridine
Phenol
Butyl phthalate
Butyl alcohol
Hydrofluoric acid [50%]
Furfurol
n-Propyl alcohol
Propylene glycol
Bromochloroethane
n-Hexane
n-Hexyl alcohol
n-Heptane
Benzene
n-Pentane
Boric acid
Gallic acid
Formic aldehyde
Methyl methacrylate
Methyl alcohol
Methyl isobutyl ketone
Methyl ethyl ketone
Ethyleneglycol monomethyl ether
Monoethanolamine
Morpholine
Butyric acid
Sulphuric acid [10%]
Ammonium sulfate
Sodium bisulfate [10%]
Iron sulfate (ll)
Sodium sulfate
Phosphoric acid [85%]
ChemicalMain body Seal
Special FKMChemical
Main body
Stainless steel316
Stainless steel316
Seal
Special FKM
Carbonic acid (Humid gas and aqueous solution)
Hydrogen sulfide (Humid gas and aqueous solution)
6
Safety Instructions
The following safety instructions are intended to prevent a hazardous situation and/or equipment damage. The instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, please observe all safety practices, including ISO 4414 Note 1) and JIS B 8370 Note 2).
1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.Since the products specified here are used in various operating conditions, their compatibility with a specific pneumatic system must be based on specifications, post analysis and/or tests to meet a specific requirement. The expected performance and safety assurance is the responsibility of the person who determines the compatibility of the system. This person should continuously review the suitability of all specified items by referring to the latest information in the catalogue and by taking into consideration the possibility of equipment failure when configuring the system.
2. Only trained personnel should operate pneumatic machinery and equipment.Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until the safety of the worker is confirmed.1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm that all safety precautions have been followed. Cut the
supply pressure for this equipment and exhaust all residual compressed air in the system.3. Before restarting any machinery/equipment excercise caution to prevent quick extension of a
cylinder piston rod, etc.
4. Contact SMC if the product will be used in any of the following conditions:1. Conditions and environments beyond the given specifications, or if product is used outdoors.2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having a negative affect on people, property, or animals, requiring special safety analysis.
Warning
Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systems
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Series KQG
Caution : Operator error could result in injury or equipment damage.
Warning : Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possible result of serious injury or loss of life.
7
Series KQGSpecific Product Precautions 1Be sure to read before handling. Refer to page 4 for safety instructions.
1. Do not use in locations where the connecting threads and tu-bing connection will slide or rotate. The connecting threads and tubing connection will come apart under these conditions.
2. Use tubing at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tube.
3. Consult with SMC regarding fluids other than air, water andnitrogen gas.
4. In case of liquid fluids, keep surge pressure at or below the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, damage to the fittings and tubing may occur.
1. Installation of tubing1) Using tube cutters TK-1, 2 or 3, take a tube having no
flaws on its periphery and cut it off at a right angle. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making installation impossible or causing problems such as disconnection and leakage.
2) Hold the tubing and slowly insert it all the way into the fit-ting.
3) After inserting the tubing, pull on it lightly to confirm that it will not come out. If it is not securely installed all the way into the fitting, problems such as leakage or disconnection of the tubing can occur.
4) Grease is not used therefore, a greater insertion force is re-quired when the tubing is installed. In particular, polyuret-hane tubing may fold when inserted due to its softness. Hold the end of the tubing, and insert it all the way in slowly and securely. Refer to dimension "M" in the dimen-sion drawings for guidance on the insertion depth of tubing.
2. Removal of tubing1) Sufficiently depress the release bushing and tubing, ma-
king sure to apply even pressure around the release bus-hing.
2) Pull out the tubing while depressing the release bushing so that it does not pop out. If the release bushing is not de-pressed sufficiently, there will be an increased bite on the tubing and it will become more difficult to pull out.
3) When the removed tubing is reused, first cut off the section of the tubing which has been clamped.Reusing the clamped portion of the tubing can cause pro-blems such as leakage, difficulties in removal, etc.In addition, for tubing used at a high temperature or for an extended period of time, there is a possibility that it will not fit into an one-touch fitting again due to an enlarged O.D. dispose of the tubing and replace it with a new one.
Installation and Removal of Tubing
Selection
Caution
Caution
Caution
1. Before mounting, please confirm that the model, size, etc. are correct. In addition, please confirm that there are no blemishes, nicks or cracks in the product.
2. When tubing is connected, consider factors such as changes in the tubing length due to pressure, and give adequate spa-ce.
3. Mount so that the fittings and tubing are not subjected to strain or moment loads. This can cause damage to the fittings and flattening, bursting or disconnection of the tubing, etc.
4. Mount so that tubing is not damaged due to tangling and abra-sion. This can cause flattening, bursting or disconnection of the tubing, etc.
Mounting
Caution
1. For M5Tighten the screw within 1.0 to 1.5 N•m of the proper tighte-ning torque. As a guide, after tightening by hand, tighten ap-proximately 1/6 turn further using a tightening tool. Excessive tightening can cause air leakage due to thread damage or de-formation of the gasket, etc. Insufficient tightening can cause loose threads and air leakage, etc.
2. Taper threadsWhen installing, tighten with the proper torque shown in the table below. As a rule, this corresponds to two or three turns with a tool after being tightened by hand.
Installation of Threads
Caution
Connection thread size
R 1/8
R 1/4
R 3/8
R 1/2
Proper tightening torque N⋅m
7 to 9
12 to 14
22 to 24
28 to 30
Installation of Threads
3. Tightening toolsTighten with an appropriate wrench using the hexagon wrench flats on the body.Tighten by placing an appropriate wrench firmly against the fit-ting body. Position the wrench on the base as close as possi-ble to the threads. If the wrench size is not correct, the fitting body may be damaged.
Series KQGSpecific Product Precautions 2Be sure to read before handling. Refer to page 4 for safety instructions.
1. Our product warranty is not valid if tubing brands other than from SMC are used.
Precautions on Use of Other Tubing Brands
Caution
1. Pre-maintenance inspectionWhen the product is removed, turn off the power, cut off the supply pressure, and confirm that fluid in the piping has been discharged.
2. During regular maintenance, check for the following and repla-ce any components as necessary.a) Scratches, gouges, abrasion, corrosionb) Leakagec) Flattening or distortion of tubingd) Hardening, deterioration or softness of tubing
3. Do not repair the fittings or patch the tubing for reuse.
Maintenance
Caution1. Do not use in environments or locations where there is a dan-
ger of damage to the fittings and tubing.For fitting and tubing materials, refer to specifications and construction drawings, etc.
2. Do not operate in locations where vibration or impact occurs because this can cause leakage, damage to fittings, etc. Plea-se contact SMC regarding use in these environments.
Operating Environment
Warning
8
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA,
TAIWAN, THAILAND, USA, VENEZUELA
OTHER SUBSIDIARIES WORLDWIDE:
© DiskArt™ 1988
© DiskArt™ UKSMC Pneumatics (UK) LtdVincent Avenue, Crownhill, Milton Keynes, MK8 0ANPhone: +44 (0)800 1382930 Fax: +44 (0)1908-555064E-mail: [email protected]://www.smcpneumatics.co.uk
AustriaSMC Pneumatik GmbH (Austria).Girakstrasse 8, A-2100 KorneuburgPhone: +43 2262-62280, Fax: +43 2262-62285E-mail: [email protected]://www.smc.at
Czech RepublicSMC Industrial Automation CZ s.r.o.Hudcova 78a, CZ-61200 BrnoPhone: +420 5 414 24611, Fax: +420 5 412 18034E-mail: [email protected]://www.smc.cz
PortugalSMC Sucursal Portugal, S.A.Rua de Engº Ferreira Dias 452, 4100-246 PortoPhone: +351 22-610-89-22, Fax: +351 22-610-89-36E-mail: [email protected]://www.smces.es
BelgiumSMC Pneumatics N.V./S.A.Nijverheidsstraat 20, B-2160 WommelgemPhone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466E-mail: [email protected]://www.smcpneumatics.be
LithuaniaSMC Pneumatics Lietuva, UABSavanoriu pr. 180, LT-01354 Vilnius, LithuaniaPhone: +370 5 264 81 26, Fax: +370 5 264 81 26
LatviaSMC Pneumatics Latvia SIASmerla 1-705, Riga LV-1006, LatviaPhone: +371 781-77-00, Fax: +371 781-77-01E-mail: [email protected]://www.smclv.lv
SwedenSMC Pneumatics Sweden ABEkhagsvägen 29-31, S-141 71 HuddingePhone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90E-mail: [email protected]://www.smc.nu
FranceSMC Pneumatique, S.A.1, Boulevard de Strasbourg, Parc Gustave EiffelBussy Saint Georges F-77607 Marne La Vallee Cedex 3Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010E-mail: [email protected]://www.smc-france.fr
FinlandSMC Pneumatics Finland OYPL72, Tiistinniityntie 4, SF-02031 ESPOOPhone: +358 207 513513, Fax: +358 207 513595E-mail: [email protected]://www.smc.fi
EstoniaSMC Pneumatics Estonia OÜLaki 12-101, 106 21 TallinnPhone: +372 (0)6 593540, Fax: +372 (0)6 593541E-mail: [email protected]://www.smcpneumatics.ee
GreeceS. Parianopoulus S.A.7, Konstantinoupoleos Street, GR-11855 AthensPhone: +30 (0)1-3426076, Fax: +30 (0)1-3455578E-mail: [email protected]://www.smceu.com
TurkeyEntek Pnömatik San. ve Tic Ltd. Sti.Perpa Tic. Merkezi Kat: 11 No: 1625, TR-80270 Okmeydani IstanbulPhone: +90 (0)212-221-1512, Fax: +90 (0)212-221-1519E-mail: [email protected]://www.entek.com.tr
PolandSMC Industrial Automation Polska Sp.z.o.o.ul. Konstruktorska 11A, PL-02-673 Warszawa, Phone: +48 22 548 5085, Fax: +48 22 548 5087E-mail: [email protected]://www.smc.pl
NetherlandsSMC Pneumatics BVDe Ruyterkade 120, NL-1011 AB AmsterdamPhone: +31 (0)20-5318888, Fax: +31 (0)20-5318880E-mail: [email protected]://www.smcpneumatics.nl
IrelandSMC Pneumatics (Ireland) Ltd.2002 Citywest Business Campus, Naas Road, Saggart, Co. DublinPhone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500E-mail: [email protected]://www.smcpneumatics.ie
HungarySMC Hungary Ipari Automatizálási Kft.Budafoki ut 107-113, H-1117 BudapestPhone: +36 1 371 1343, Fax: +36 1 371 1344E-mail: [email protected]://www.smc.hu
SwitzerlandSMC Pneumatik AGDorfstrasse 7, CH-8484 WeisslingenPhone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191E-mail: [email protected]://www.smc.ch
ItalySMC Italia S.p.AVia Garibaldi 62, I-20061Carugate, (Milano)Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365E-mail: [email protected]://www.smcitalia.it
GermanySMC Pneumatik GmbHBoschring 13-15, D-63329 EgelsbachPhone: +49 (0)6103-4020, Fax: +49 (0)6103-402139E-mail: [email protected]://www.smc-pneumatik.de
SloveniaSMC industrijska Avtomatika d.o.o.Grajski trg 15, SLO-8360 ZuzemberkPhone: +386 738 85240 Fax: +386 738 85249E-mail: [email protected]://www.smc.si
SlovakiaSMC Priemyselná Automatizáciá, s.r.o.Námestie Martina Benku 10, SK-81107 BratislavaPhone: +421 2 444 56725, Fax: +421 2 444 56028E-mail: [email protected]://www.smc.sk
RomaniaSMC Romania srlStr Frunzei 29, Sector 2, BucharestPhone: +40 213205111, Fax: +40 213261489E-mail: [email protected]://www.smcromania.ro
NorwaySMC Pneumatics Norway A/SVollsveien 13 C, Granfos Næringspark N-1366 LysakerTel: +47 67 12 90 20, Fax: +47 67 12 90 21E-mail: [email protected]://www.smc-norge.no
DenmarkSMC Pneumatik A/SKnudsminde 4B, DK-8300 OdderPhone: +45 70252900, Fax: +45 70252901E-mail: [email protected]://www.smcdk.com
RussiaSMC Pneumatik LLC.4B Sverdlovskaja nab, St. Petersburg 195009Phone.:+812 718 5445, Fax:+812 718 5449E-mail: [email protected]://www.smc-pneumatik.ru
SpainSMC España, S.A.Zuazobidea 14, 01015 VitoriaPhone: +34 945-184 100, Fax: +34 945-184 124E-mail: [email protected]://www.smces.es
http://www.smceu.comhttp://www.smcworld.com
EUROPEAN SUBSIDIARIES:
BulgariaSMC Industrial Automation Bulgaria EOOD16 kliment Ohridski Blvd., fl.13 BG-1756 SofiaPhone:+359 2 9744492, Fax:+359 2 9744519E-mail: [email protected]://www.smc.bg
CroatiaSMC Industrijska automatika d.o.o.Crnomerec 12, 10000 ZAGREBPhone: +385 1 377 66 74, Fax: +385 1 377 66 74E-mail: [email protected]://www.smc.hr
1st printing KU printing KU 00 UK Printed in Spain