Standard Plans for Accessory Dwellings/Farmworker Housing General Information Fact Sheet ___________________________________________________________ Standard plans are available for three different sizes and accessory dwelling unit configurations: 1. 700 square foot, one-bedroom unit 2. 900 square feet, two-bedroom unit 3. 1,200 square feet, three-bedroom unit When an applicant applies for permits to construct an accessory dwelling unit using one of the standard plans, the standard plan cannot be modified in any way. A separate building permit is required for each unit constructed. Also, a geotechnical/soils report must be prepared for the 1,200 sq. ft. standard plan. Building permits for Accessory Dwelling Units will only be issued to the property owner or to a licensed contractor who has been contracted to do the work. If the permit is issued directly to the owner, the owner must do the construction. The Accessory Dwelling housing plan is not to be used for construction of homes in the Lockwood Valley area or other areas above the 4,000 ft. elevation. The Ventura County Building Code does not allow approval of these standard plans in those areas. These standard plans are not to be used for construction of homes in the La Conchita area or other areas with adverse geotechnical conditions. The foundations for these structures have not been designed to accommodate adverse geotechnical forces or movement.

Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

Standard Plans

for Accessory Dwellings/Farmworker Housing

General Information Fact Sheet

___________________________________________________________

Standard plans are available for three different sizes and accessory dwelling unit configurations:

1. 700 square foot, one-bedroom unit 2. 900 square feet, two-bedroom unit 3. 1,200 square feet, three-bedroom unit

When an applicant applies for permits to construct an accessory dwelling unit using one of the standard plans, the standard plan cannot be modified in any way.

A separate building permit is required for each unit constructed. Also, a geotechnical/soils report must be prepared for the 1,200 sq. ft. standard plan.

Building permits for Accessory Dwelling Units will only be issued to the property owner or to a licensed contractor who has been contracted to do the work. If the permit is issued directly to the owner, the owner must do the construction.

The Accessory Dwelling housing plan is not to be used for construction of homes in the Lockwood Valley area or other areas above the 4,000 ft. elevation. The Ventura County Building Code does not allow approval of these standard plans in those areas. These standard plans are not to be used for construction of homes in the La Conchita area or other areas with adverse geotechnical conditions. The foundations for these structures have not been designed to accommodate adverse geotechnical forces or movement.

Page 2: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

Standard Plans for Accessory Housing

Checklist for using a Standardized Plan

___________________________________________________________

Conduct Initial Review

Step 1: Verify the lot status and if the zoning for the property allows this type of building. Contact or visit the County’s Planning Division to check zoning consistency and legal lot status. Each Zone has development standards requiring appropriate building setbacks, lot coverage, etc. that must be met.

Step 2: Verify that the property is not subject to adverse geotechnical conditions and meets slope setback requirements. Contact or visit the Building & Safety Division. In some cases, you may then be referred to the Public Works Agency.

Step 3: Verify that the property will have adequate water supply. For properties served by a private water well (1-4 connections, less than 25 people served annually) located on the property, obtain clearances from County’s Watershed Division and a Certification of Water Quality from the Environmental Health Division. Separate review fees will apply. Private water wells must meet minimum flow and water quality standards to obtain approval. For properties connected to a public water system, obtain a clearance or Will Serve letter from your local water purveyor.

Step 4. Verify that the property will have adequate sewage disposal. If the property is served by an on-site waste treatment system (septic system), contact or visit the County’s Environmental Health Division. Separate review fees will apply. See attached table for preliminary septic system design information. If served by a pubic sewer entity, a clearance from that entity must be provided.

Step 4. Verify if the building must have a fire sprinkler system and if fire access and water flow are adequate on the site. Contact the Fire Protection District.

Obtain Final Clearances…Obtain the following permits/clearances and pay associated fees:

• Planning – Zoning Clearance, and tree permit, if necessary; if standards are met, this is usually issued in one day.

• Environmental Health (septic system) – approved septic system plan; Environmental Health staff will review the septic system design and geotechnical report. The review process takes approximately two weeks and is followed by the issuance of a permit to construct a new septic system, or a full certification of an existing septic system.

• Environmental Health (well water) – approved certification of water quality; Environmental Health staff will review information such as: water quality results, an approved pump and recovery test, and a site plan. The certification process takes approximately two weeks, includes a site inspection, and is followed by an approved certification of water quality form.

Page 3: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

Standard Plans for Farmworker and Accessory Dwelling Units in

Unincorporated Ventura County

Ventura County Board of Supervisors MeetingOctober 24, 2017

Page 4: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

Standard Plans for Accessory/Farmworker Dwellings

Project Objectives:

• Address concerns raised by the farming community that the development of farmworker housing was too difficult

• Fulfill Housing Element Program 3.3.3-5(9) to develop pre-approved building plans for second dwelling units.

Page 5: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

201

6 V.

C.6.

0 A

ND

20

16 C

.R.C

.

FAR

MW

OR

KE

R D

WE

LLIN

G

— TYPICAL DETAILS

I■

Arlr ) rxr CA Ap • fll • AC-

MOO

1 - 1113 41110runc pup S. 4 II. I /0 In RI cm... ups.% APPSIPX Pre, 911. nun urEs IEr/PRI 1 3 /111

• 911 911. TO IX A. 1

:rr::nc:/tn1rP•rRn7:L

::1•• •- /IMAPI`•/' 'tp•"--/.7`317/

' rEmin • / ■••114; — • -

MAYO 41114115 FOR RONI.113 X 031411. InASE=1//171/E04COR

MM. Pr INIARRETMERS ACO/4001L '//mAFRP SPE GIP 11411C A AILLOAOS 1.14

SHEAR WALL SCHEDULE

-y-war- co•Nn, IP=

PIPE THFtu CONTINUOUS FOOTING IL. HEADERS FRAMING & SCHEDULE

0214=110.1 A3S

SEA ANCHORS (REK KW KO

CONSTRuCTCN JOINT

stAN CONSTRUCTION

SRUCES CSTANOARO SCHEOLLE AMA SFIRS15 1190115

TSS 111riX

nEDIR 49XPS 7.1•1,1/../

r[1/•"••coArl•E Ar•-••••5 S WAM CR 04.1R SPAS4

LP. LE

1.1411 L

i F 1,11 SR. IN IVOONIP SNIP

. R03. 90.nr ror nPerrAt 4

; E,

,I AL. LOLLIE AL4O-

5-1911 LAO NEWILLIAM WAS ALI 1.1.1r nun InCAPI puss, up ADM sr SW

nr. C. 4,7 Al

reR3ACO

IA p510

mmmmmm Pal

/•2" I /7771/11......1. • X Kr 113 111 1111 IIA AI a

A II II a I hi th 444144 A p 5 ET 'V 73. 3. ..

ILL

LOLA 1411510114141•11.111.

.13‘ AR 091 10 IA Nr IA

Eli, ill 11/

Affia.S.M CF SLAB

13 FOOTING INTERSECTION

MEM -21E44 A., AL 2- LAACER NAN 001100 -00ACLJ11 WALL LAT 51 LCOVID WO.144 A 45514*104 OR LUDO A POOL

r4S 515)10 TCIST)) III Coot

h r/-

1

WARINR WAI I

C131A OT

ourpon

rt •

LISS: P;,,, sI40)015EIL112215J:1EalLs

001 LAIN & BEM IlE PeR REBAR BEND A SPLIC

HEADER SOFEOuLE

ILK 7411 DO Mae, OWL

OOP

SALL 2. ILA

AAA 4 OLD

3-7n TAW

1r SUP PPR

.fg• 313.

4.1 RE8AR BEND, SPLICE & HOOK. [ IS TYP. STUD BORING & NOTCHING 12 PIPE PENETRATION AT TOP PLATE 9 TYP. liORIZ. DIAPHRAGM Iiilladtga....4.1.4=4.11LA&AlmuataNigrzlcalk...4.4

Page 6: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

I'

cl_11,1rer PPAANK

700 s.f.

r

2.1 CP SVETS

SECTION A G.M.I.11N3,70A-1 30.11,1a1.11,14.01.4.111.1.11111g Aram.

FLOOR FLAN ROOF PLAN

NOTES:

1, THE MINIMUM NET FREE VENTILATING AREA SHALL BE Xso OF THE AREA OF THE VENTED SPACE- USE 8 F -1z OF VENTILATING AREA.

2. IN 11101-1 FIRE HAZARD AREAS. EAVE VENTILATION SHALL hal BE USED.

WINDOW AND DOOR SCHEDULE

SYMBOL TYRE SIZE(FIXW Fr) OPERATION REMARKS

0 wow v-cemv-o - SLIDING a WINDOW 2'-0"x2' -0" SLIDING

DOOR 8.-8-5<3.-4-

• USE TEMEPERED GLAZING IN HIGH FIRE HAZARD AREAS

LEGEND:

ID SMOKE DETECTOR

O CARBON moNoxiDE ALARM

1:11 BATHROOM FAN

• WHOLE HOUSE FAN

e KITCHEN EXHAUST FAN

• WINDOW

• DOOR

Page 7: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

FLOOR PLAN 1Sy.

-e .

Ii

ROOF PLAN

2016 V

.C.B

.0 A

ND

2D

16 C

.R.C

.

FAR

MW

OR

KE

R D

WE

LLIN

G

SECTION A

NOTES:

1. THE MINIMUM NET FREE VENTILATING AREA SHALL RE K50 OF THE AREA OF THE VENTED SPACE USE 13 Fle OF VENTILATING AREA_

2, IN HIGH FIRE HAZARD AREAS, EA VE VENTILATION SHALL NM BE USED.

N DOW AND DOOR SCH ED ULE

SYMBOL TYPE SIZE(1-IKW FT) OPERATION REMARKS

® WINDOW 8. -0-x4'-0" SLIDING e WINDOW V-0"x2'-0 ° SLIDING •

DOOR B -6 x3 -4

• USE TEMEPERED GLAZING IN HIGH FIRE HAZARD AREAS

LEGEND:

ej) SMOKE OETECTOR

• CARBON MONOXIDE ALARM

ela BATHROOM FAN

4E) WHOLE HOUSE FAN

elo KRONEN EXHAUST FAN

O WINDOW

3 DOOR

L.

Page 8: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

1— — — ---1111 --1 1 I 1 I 1 I 1 I

I Ii L r - - -

- L _

Li < I

11

ROOF PLAN

NOTES:

1. THE MINIMUM NET FREE VENTILATING AREA SHALL BE Nso. OF THE AREA OF THE VENTED SPACE. USE 8 FT" OF VENTILATING AREA.

2. IN HIGH FIRE HAZARD AREAS, CAVE VENTIOTION SHALL LID.2 E USED

WINDOW AND DOOR SCHEDULE

SYMBOL TYPE SIZE(I1XW FT) OPERATION REMARKS

.0 WINDOW S'-0-m4'-O SLIDING 8 WINDOW 2'-frx2' -0" SLIDING •

DOOR 6'-frx 3r-4"

• USE TEMEPERED GLAZING IN HIGH FIRE HAZARD AREAS

uII

21•221,3

FLOOR PLAN

"NSW"

111.40 VM11 . 42

MIT 'ME

106 M.

2.1

1200 s.f.

2016

V.C

.B.0

AN

D 2

016

C.R

.C.

FA

RM

WO

RK

ER

DW

ELL

ING

SECTION A

M . 3

mem

I

10 . 10 ■■__

- III1 A- I I- etTIR0011 3

0

*I 1Z1

E

:K.

-c BEDROOM 1 21

MEM .121

1".] CI

1 I

LIVING/ MMHG

Ann

!...!. i.:i.

Mk. --

®

I 1 12 1

K1TOMEM 12,0 BEDROOM 2

3-1 1Wit .

LEGEND:

O SMOKE DETECTOR

O CARBON MONOXIDE ALARM

• BATHROOM FAN

a WHOLE HOUSE FAN

e KITCHEN EXHAUST FAN

® WINDOW

1111 DOOR

L.

Page 9: Standard Plans for Accessory Dwellings/Farmworker Housingcolabvc.org/wp-content/uploads/2017/12/Standard-Plans-for-ADUs-a… · Standard Plans . for Accessory Dwellings/Farmworker

ASSESSORY DWELLING UNIT SEPTIC SYSTEM SIZING GUIDELINES

For farmworker dwellings with </= 25 plumbing fixture units Septic tank size = 1,000-gallon capacity

Size of Dwelling

(Square Feet) Percolation Rate

(minutes/inch) Leach Line Length in Feet

Based on Standard leach line size: (3 feet wide, 30 inches or 2.5 feet of rock below pipe)

700

Up to 45 50 60 55

900

5 50 15 63 30 83 45 100 60 110

1,200

5 63 15 95 30 125 45 150 60 165

Dwelling specifications: 700 ft2 = 1 bedroom, 1 full bath, kitchen, washer

900 ft2 = 2 bedrooms, 1 full bath, kitchen, washer

1,200 ft2 = 3 bedrooms, 2 full baths, kitchen, washer

This chart should only be used for general guidance where:

✓ Highest groundwater is at least 10 feet below surface. ✓ 5-foot separation exists between bottom of leach line(s) and bedrock. ✓ Surface waters, such as streams, drainage channels, ponds, subsurface drainage systems

are at least 100 feet from the leach line(s). ✓ All water wells are at least 150 feet from the leach line(s). ✓ Surface slope does not exceed 25%. ✓ Available public sewer is greater than 200 feet from the parcel.

NOTES:

1. The information on this chart is not a full listing of applicable requirements; local conditions may result in differing requirements.

2. All septic systems must be designed by a California Registered Professional Engineer or Registered Environmental Health Specialist and installed in conformance with Appendix Chapter H of the Ventura County Building Code.

3 Ft.

2.5

3

1 Minimum

1-Foot

4