STAR Time-Projection Chamber Huan Zhong Huang Department of Engineering Physics Tsinghua University & Department of Physics and A stronomy University of California, Los Angeles Thanks to Gene Van Buren, Jim Thomas, Blair Stringfellow

STAR Time-Projection Chamber

  • Upload
    javen

  • View
    70

  • Download
    0

Embed Size (px)

DESCRIPTION

STAR Time-Projection Chamber. Huan Zhong Huang Department of Engineering Physics Tsinghua University & Department of Physics and Astronomy University of California, Los Angeles Thanks to Gene Van Buren, Jim Thomas, Blair Stringfellow and Howard Wieman. - PowerPoint PPT Presentation

Citation preview

Page 1: STAR Time-Projection Chamber

STAR Time-Projection Chamber Huan Zhong Huang

Department of Engineering PhysicsTsinghua University

& Department of Physics and Astronomy University of California, Los Angeles

Thanks to Gene Van Buren, Jim Thomas, Blair Stringfellow and Howard Wieman

Page 2: STAR Time-Projection Chamber

STAR

Relativistic Heavy Ion Collider --- RHIC

Au+Au 200 GeV N-N CM energyPolarized p+p up to 500 GeV CM energy

Page 3: STAR Time-Projection Chamber

STAR Physics Approaches

Emphasis on Observables Sensitive to Early Partonic Stages:

1) High pT particles – Jet quenching? New baryon dynamics? 2) Particle fluctuations and large scale correlations – probe

conditions near phase boundary.3) Partonic collective flow observables especially for those particles

believed to have small hadronic re-scattering cross sections, D mesons and J/.

4) D meson production for initial gluon flux and structure function of nuclei.

5) J/ for possible color screening effect6) Direct and thermal photon production

Precision Measurements to Map Out Hadronic Evolution Dynamics

1) Resonances (,,f0, K*, , (1385) and(1520)) – Sensitive tohadronic evolution between chemical and kinetic freeze-out

2) Momentum-space-time relations at the kinetic freeze-out thrucorrelations of identical, non-identical pairs, and light clusters.

Page 4: STAR Time-Projection Chamber

STAR Schematic

Page 5: STAR Time-Projection Chamber

The STAR Detector

• Electron ID• energy loss in the tracking detectors (TPC dE/dx)• time of flight measurement (TOF)• calorimetric measurements (EMC)

Page 6: STAR Time-Projection Chamber

STAR TPC Geometry

Page 7: STAR Time-Projection Chamber

The STAR Time Projection Chamber

Inner and Outer Field Cages

Central Membrane

Page 8: STAR Time-Projection Chamber
Page 9: STAR Time-Projection Chamber

Anode Wire-Pad Plane Readout

Page 10: STAR Time-Projection Chamber

Typical TPC Readout

Page 11: STAR Time-Projection Chamber

Limitations on Wire-Pad Readout1) The induced charge distribution on the pad plane is much wider than the intrinsic avalanche width --- wire-pad readout scheme not matching the true two-hit resolution capability of the gas detector

2) The width of the induced charge distribution depends on the separation between the anode and pad planes

--- STAR inner sectors 2 mm gap outer sectors 4 mm gap

3) Mechanical stability and wire plane accuracy limit the gap separation

4) In high multiplicity environment the anode wire readout is not very useful

Page 12: STAR Time-Projection Chamber

Hit Position from Pad Readout

Ideally the induced signal should be distributed across three pads with amplitudes h1, h2 and h3.

)/ln(2

)/ln(

13

2

3122

22

hhw

x

hhh

w

Pad Plane

0 x

h1 h2 h3

Induce charge distribution

Non-Gaussian shape better use weighted average --- Laser signals --- Drift direction

Page 13: STAR Time-Projection Chamber

STAR TPC Characteristics

P10 Gas

Page 14: STAR Time-Projection Chamber

Electrons Transport in Gas Electron clouds from primary ionization drift towards the anode and undergo diffusionD – diffusion coefficientUnder magnetic field (parallel to Electric Field E) the transverse diffusion coefficient --

2)(1)(

T

T

DBD

P10 Gas – ~ 2.30 at 0.5 T DT(0.5T) = 230 m/sqrt(cm) DL = 360 m/sqrt(cm)Diffusion Contribution ~ D*sqrt(L) For L=200 cm drift in STAR TPC T ~ 3.3 mm; L ~ 5.1 mm-- Anode Wire – Pad Plane two-hit resolution does not match the diffusion limit – motivation for GEM read-out !!

Page 15: STAR Time-Projection Chamber
Page 16: STAR Time-Projection Chamber

Two-Hit Resolutions

Inner Sector Pads – 2.85 x 11.5 mmOuter Sector Pads – 6.20 x 19.5 mm

Page 17: STAR Time-Projection Chamber

Laser System for Drift Velocity

Page 18: STAR Time-Projection Chamber

TPC Laser Tracks

Laser System -- 500 laser triggers every a few hours ! -- drift velocity ~ 0.02%

Page 19: STAR Time-Projection Chamber

What Happens to Positive Ions?

Gate open Gate closed

Page 20: STAR Time-Projection Chamber
Page 21: STAR Time-Projection Chamber

Large Data Set is needed for correction studies !

Page 22: STAR Time-Projection Chamber
Page 23: STAR Time-Projection Chamber
Page 24: STAR Time-Projection Chamber
Page 25: STAR Time-Projection Chamber
Page 26: STAR Time-Projection Chamber
Page 27: STAR Time-Projection Chamber
Page 28: STAR Time-Projection Chamber
Page 29: STAR Time-Projection Chamber

2

2ln

14 2

222

2222

I

cm

A

ZzcmrN

dx

dE eeeA

Ionization Energy

Bethe-Bloch Formula

density effect

ionization constant

Page 30: STAR Time-Projection Chamber

STAR TPC: Ar-CH4 (90-10) Atmosphere Pressure45 max samples

Particle Identification Using dE/dx

Kp

d

e

Inner Sector pads smaller – not as good as outer pads for dE/dx

Page 31: STAR Time-Projection Chamber

Momentum Resolution: the STAR Magnet+TPC

• Momentum resolution is only limited by the strength of the magnetic field and is independent of the mass of the particle at high PT

• Momentum resolution at low PT is determined by multiple coulomb scattering (MCS)

MCS Contribution

B Field limited

Page 32: STAR Time-Projection Chamber

Reconstruct Ks, and

KS π+π- (i/ 69%), c = 2.69cm

Λ pπ- (i/ 64%), c = 7.89cm

- Λπ- (i/ 99.9%), c =4.91cm

(Ks)

p(+)

Decay vertex-

Primary Vertex

p

-

Primary Vertex

-

-

STARSTAR

Page 33: STAR Time-Projection Chamber

STAR TPCThe STAR TPC has performed as designed -- unexpected space-charge problem due to higher RHIC luminosity ~ 6 x design luminosity some charge leakage in the gating grid boundary can be corrected for reliably so far

STAR benefited from 1) better than design spec on construction and E and B

alignment 2) TPC has two almost independent halves

(central membrane) 3) many monitor systems and lots of data

STAR TPC upgrade – FEE and DAQSTAR TPC is expected to perform at RHICII @40 x design L

Page 34: STAR Time-Projection Chamber

Multi-Gap Resistive Plate Chamber

E. Gorini et al. Nucl. Instr. Meth. A 396(1997)93

Page 35: STAR Time-Projection Chamber

Good time resolution (<100ps), high detection efficiency(>95%),high granularity, robustious, low cost ($2M +electronic).

USTC and Tsinghua

Page 36: STAR Time-Projection Chamber

Chinese MRPC Works

TOF “alone” PID pT range:

/K ~1.6GeV/c,

(,K )/p ~ 3.0GeV/c

Chinese STAR Groups – Shanghai Institute of Applied Physics, University of ScienceAnd Technology of China, Tsinghua University, Hua Zhong Normal University and Institute of Modern Physics at LanZhou

Page 37: STAR Time-Projection Chamber

The End

Page 38: STAR Time-Projection Chamber

The sagitta is determined by 3 measurements with error (x):

( N > 10 )

L

s

B

y

x

qBpBvq

mvT )(

2

23

223.

3.0

8)()()(

BL

px

s

x

s

s

p

p T

meas

T

T

)( 3121

2 xxxs

m)(T3.0)cGeV( BpT

Tp

BLL

3.022sin

2

Tp

BLs

22

8

3.0

82cos1

Momentum Measurement in a Uniform Field

)4/(720

3.0

)(2

.

NBL

px

p

p T

meas

T

T

Page 39: STAR Time-Projection Chamber

TRANSITION AVALANCHE TO STREAMER