StarterKit EN

Embed Size (px)

Citation preview

  • 8/7/2019 StarterKit EN

    1/13

    INELS MAY NOT BE JUST A COMPREHENSIVE SOLUTION!

    LIGHTING

    16 2/49

    ALARMHEATING REMOTECONTROL INTERNET GSM SHUTTER

    Starter itK

    INELS MAY NOT BE JUST A COMPREHENSIVE SOLUTION!

  • 8/7/2019 StarterKit EN

    2/13

    LIGHTING HEATINGREMOTE

    CONTROLINTERNET GSM SHUTTER

    6 21 9/4

    ALARM

    INELS may not be just a comprehensive solution!

    Are you looking for a smart way of controlling the appliances or

    devices in your home? Do you want to make your home shine? Do youwish to play with the lights, create light scenes or just to cut down on

    costs by means of dimming? Is a comprehensive system too expensive

    for you? Then our INELS Starter Kit, a partial solution package

    containing basic units for the given area with optional further

    extension up to a complex system, is the right solution for you.

  • 8/7/2019 StarterKit EN

    3/13

    Starter itK

    StarterKit will enable you to control the lighting,

    appliances, blinds and heating

    Morning lighting can be set according to

    the intensity of the exterior light

    The purpose of the Inels system

    is to bring you, the user, an

    intelligent electric installation

    tailored to suit your needs for ana d v a n t a g e o u s p r i c e ;

    the implementations ranging from

    smallest applications with a partial

    s o l u t i o n u p t o v a s t a n d

    comprehensive systems.The scope of the Inels system

    StarterKit is suitable for partial

    implementations of partial areas

    of your electric installations. That is

    why it can be used to control onlycertain standalone parts such as

    heating, dimming, controlling

    the blinds, switching appliances

    on and off or communicating with

    a security system.

    INTRODUCTION

    No matter whether you purchase the LIGHT StarterKit (to control and dim lighting), HEATING (to regulate

    heating) and/or BLINDS (to control blinds, jalousies or sunshades), you can always be sure that you have

    bought the best that there is. This is because you ar e totally free to set everything as you need and to

    modify the settings at any time.

    The INELS StarterKit grows with you!

    The INELS StarterKit contains basic components for the given area of intelligent electric installation

    (LIGHT / HEATING / BLINDS) which can be mutually combined in any way or extended in the future. You

    can also choose a combination of the above mentioned areas (e.g. LIGHT and HEATING) and/or work

    your way towards a comprehensive intelligent electric installation system, which INELS doubtless

    represents.

    Flexibility and customisation these are two key advantages of the INELS system. All modifications of

    functions are done in IDM soft ware, supplied free of charge, on the PC ; unlike the classical installation

    where you have to insert or replace devices offering a certain functionality in the system (which

    the location or the layout of cables often renders impossible).

    All of the components of the INELS StarterKit offer full performance and, if included in a comprehensive

    system, offer the same parameters.

    The StarterKit is pre-connected and pre-programmed; i.e. the device will work as soon as it is plugged

    in so that you can try it out. However, as these are connected to a 230 V power supply, they must be

    installed by a qualified technician.

    The StarterKit Manual serves to provide you with a basic presentation of the system; go to the IDM

    Manual for advanced setting information. If you are interested in setting or extending the system,

    contact the network of our authorised system partners (see http:www.inels.com).

    HEATINGLIGHTING

    Basic terms used in intelligent electric installation:

    Unit

    The term of unit refers to e.g. a switching actuator, input module or a thermostat connected to the bus. It is possible to connect up to 32 units to a

    single bus. The central unit contains two buses and MI2-02M modules enable extending the system by further 4 buses = 6 buses = 192 units. The

    unit does not refer to the number of connected components (e.g. switches or buttons) because a unit mostly features several inputs or outputs.

    Lowering blinds and regulating the brightness of lighting

    fixtures as the exterior light intensity decreases

    The data from the weather station help you control

    the lighting, blinds as well as heating

    Setting-off of the light alarm in the event of

    unauthorised entry

    Sensor

    The term of sensor refers to a unit scanning a certain quantity, e.g. pressing a button, temperature, lighting level, voice, IR signal from

    the remote control etc.

    Actuator

    The term of actuator refers to a unit controlling an appliance; it e.g. switches a socket, dims a lighting fixture, controls a thermal head, sends

    a signal etc.

    IDM

    This is the acronym which stands for the INELS Designer & Manager freely supplied software used for setting the par ameters of the functions of

    the entire system.

    Bus

    This is two conductors (wires) mostly a twisted parallel pair connecting all units in the building. The central units use the bus to communicate

    with other units, collect information from sensors and send commands to actuators. The bus represents the main difference between

    the intelligent and classical electric installation. The indisputable advantage of the bus is the possibility of making flexible extensions or

    modifications, which is rather limited i n the event of classical installation.

    REMOTECONTROL INTERNETSHUTTER GSM

    6 /1 924

    ALARM

  • 8/7/2019 StarterKit EN

    4/13

    1 9 /46 2

    ALARMGSMSHUTTER REMOTECONTROL INTERNET

    All StarterKits feature the following basic components:

    CU2-01M central unit

    PS-30-24 power supply

    BPS2-01M separator of the bus from the power supply unit

    This is the heart of the entire system and acts as a n interface between the user software environment and other sensors/actuators on the bus. It is connected

    via a cable to a computer or network (it has a dedicated IP address). The configuration of the unit, and hence the entire system, is done in the IDM configuration

    software, which is designed for the MS Windows operating systems. The built-in web server enables remote configuration of the unit and control over user

    functions via an internet browser (o n a PC, phone or PDA). The 6-MODUL type is designed for switchboard installation.

    The 30W switched and stabilised power supply w ith 230 V power input and fi xed 24 V DC power output into the system.

    This is used for impedance separa tion of a single branch of the CIB bus. The front panel features a LED informing abo ut the voltage on CIB clamps.

    The system allows remote control and configuration via a PC It is possible to use text messages as a partial control tool

    PSM1

    PSM2

    AC 230V

    L

    N

    PS 30/24

    CIB +

    CIB -

    DC 24V / 1,25A

    3OW

    AC 230V

    5OHz / 60Hz

    LIGHTING HEATINGStarter itK

  • 8/7/2019 StarterKit EN

    5/13

    Starter itK

    Do you want to make your home

    shine? Do you wish to play withthe lights, create light scenes or

    just to cut down on costs through

    dimming?

    Control of the lighting intensity is

    a very popular way to create anenjoyabl e atm osphere, for

    pressing a single button will

    automatically turn on the lights to

    the preset intensity to suit your

    requirements for a particularactivity, i.e. your living room will

    have different light scenes forwatching TV, reading a book,

    a family dinner or chatting with

    friends.

    Regulation of the glow according to the sensor of the outdoor light

    intensity

    Sensors:

    Actuators:

    The possibility to regulate the glow of bulbs and fluorescent tubes will pay you back in a very short

    time. The lights will maintain the required constant intensity according to the intensity of the exterior

    light. This will prevent your lights from working on 100% capacity even though the sun is shining

    outside. This will be appreciated especially by the owners of companies, public institutions,

    commercial and shopping centres, i.e. everyone who pa ys for the energy.

    SOU sensor - outer sensor of the lighting intensity

    ADC2-40M - converter of the outer sensor signal to the bus

    For bulb lights DA2-22M (2x 500VA) or DIM-6 (2000VA)

    For fluorescent tube lights LBC2-02M (2 fluorescent tubes)

    LIGHT

    LIGHTING

    Automatic switch-on of the lights

    in the event of person's movement

    Automatic switch-on of the lights in the event of person's movement.

    Sensors:

    Actuators:

    Start-off of the light alarm in the event of unauthorised entry.

    Sensors:

    Persons' movement sensors (the so-called PIR sensors or also infra passive sensors) are suitable not only for securing the building and preventing from

    unauthorised access. It is possible to use this switch for other functions e.g. switching on the lights. This is suitable especially in corridors, staircases, entrances,

    toilets etc., i.e. wherever one usually moves for only a limited period of time and where the light often shines uselessly if someone forgets to turn it o ff.

    JS-20 LARGO PIR detector of persons' movement

    IM2-20B - input unit enabling the connection of 2 PIR sensors and the transfer of their signal to the bus

    SA2-02M (or SA2-02B) - switching ac tuator (2 separate outputs = 2 light circ uits) for switching

    DA2-22M - dimming actuator (2 separate o utputs) - this option enables gradual dimming of the glow a fter the movement has stopped.

    The IDM configuration programme also allows setting delayed switch-off and/or super ordinate control by means o f a button = the light can beswitched on regardless of movement (cleaning up, maintenance etc.).

    Every light connected via a switching and/or dimming unit can be a part of the so-called light alarm. Therefore, in the event of trespassing, predefined lights

    are switched on or start blinking i n addition to the text message sent and the alarm activated, which will certainly put the intruder off. The security functions

    include one which w ill considerably contribute to the safeguarding of your home, namely simulation of presence. While you are away (on holiday, visiting

    friends etc.) lights in various ro oms are switched on in irr egular intervals in the evening; the lights along your driv e will be switched on at ni ght and blinds can

    be pulled up and down to enhance the o verall effect: to make the house look as i f you were in.

    No other sensors or ac tuators are necessary. It is possible to programme this function onto any actuator and switch on by a suitable control.

    Start-off of the light alarm

    in the event of unauthorised entryRegulation of the glow according to

    the sensor of the exterior light intensity

  • 8/7/2019 StarterKit EN

    6/13

    Starter itK

    1 3 5 7

    42 6 8

    I f y o u u s e d i m m i n g a c t u a t o r s ( b u l b o r f l u o r e s c e n t t u b e ) , y o u c a n s e t a l i g h t s c e n e t o f i t e v e r y o c c a s i o n .

    The scene may meet particular requirements and/or merely create an atmosphere. The following example might help you imagine possible light

    scenes: in the living room there is a ceiling light (1), wall spotlights by the TV set (2) and a lamp by the sofa for reading (3).

    The most frequently used settings could include:

    1+3 off, 2 at 50 %

    1+2+3 at 100%

    1 at 50 %, 2 off, 3 at 70 % (or to suit one's needs and according to the output power)1+2+3 at 30%

    WSB2-80 group wall controls, 8 buttons

    DA2-02M - dimming actuator 2x500VA, 2 pieces necessary in our example

    The scenes are switched by a suitable sensor, in most cases it is the WSB2 wall control unit with 2, 4 or 8 buttons. If you use the 8-button WSB2-80 (the size

    of a single switch!), you can set the button for example in this way:

    Button 1: Controls the ceiling light (1)

    Button 2: Controls the wall spotlights (2)

    Button 3: Controls the reading lamp (3)

    Button 4: launches the Watching TV light scene

    Button 5: Launches the "Party light scene

    Button 6: Launches the "Reading light scene

    Button 7: Launches the "Intimate Moments light scene

    Button 8: Switches all off

    Buttons 1-3 enable controlling the lighting as if you were using a controlled dimmer, i.e. every time you press a button you switch lights on/off and every time

    you hold the button pressed you dim the light until you release the button, the value is then stored in the memory so that if you press the b utton again, you

    switch the light on to this preset level.

    A light scene will create a pleasant atmosphere.

    Watching TV:

    A party:

    Reading:Intimate moments:

    Sensors:

    Actuators:

    T he In ti ma te M om en ts l ig ht s ce ne L ig ht s ce ne f or s it ti ng o ut si de T he Re ad in g" l ig ht s ce ne

    LIGHTING

    Two-channel dimming actuator for fluorescent

    tubes LBC2-02M

    Cont ains 2 power ou t pu t s 0(1)-10V and

    a subordinate relay with switch contact. This unit is

    intended to control the dimming ballast.

    Components of the Light StarterKit:

    Connection of

    fluorescent tube:

    Dimming ballast DIML 218This component is used for the regulation of

    the glow of fluorescent tubes. It is controlled by 1-

    10V signal and is connected to the Inels system

    through DAC2 or LBC2 converters.

    Wall control unit with short way control WSB2-40

    The control unit features an integrated temperature

    sensor, micro buttons and a LED indicator in every

    cradle.

    Dimming two-channel actuator DA2-22MThis is intended for switching and dimming the RLC

    loads. It combines 2 230 V AC inputs and 2 semi-

    conductor controlled 230 V AC outputs.

    Connection of bulb:

    AC 230V

    DIML 218 LBC2-02M WSB2-40 DIML 218

    DA2-22M WSB2-40 LM2-11B

    CIB+

    CIB -

    7 6 5 4 3 2 1

    H L

    vstup

    220V-240V

    DC1..10V

    DIML218

    AC 230V

    NC/GND

    PE

    7 6 5 4 3 2 1

    H L

    vstup

    220V-240V

    DC1..10V

    DIML218

    NC/GND

    PE

    Thermo sensor TC

  • 8/7/2019 StarterKit EN

    7/13

    Starter itK

    The blinds and the roof of the pool close

    automatically in bad weather

    Systems of blinds and sunshades

    are designed to protect you, notonly from adverse weather.

    T o u c h e d b y t h e r a y s o f

    the morning sun, the blinds can go

    up automatically to make your

    waking pleasant while otherb l i n d s m a y r e m a i n d o w n .

    Watching TV is enjoyable even on

    sunny af ternoons; at nig ht

    the blinds reduce the risk of

    unwanted persons enteringthe building and they can also

    simulate people's presence inthe house while you are away. If

    the weather conditions change

    during the day, the sensors of

    the INELS system will guaranteethat your house or flat i s optimally

    protected.

    The blinds go up automatically with the first rays of sun,

    they are lowered as soon as the intensity of the exterior light drops.

    Sensors:

    Actuators:

    The outer sensor of the exterior light intensity just like the regulation of the lighting can be used for

    automatic lowering of blinds as soon as the intensity of the exterior light decreases under a preset

    level. You can install several sensors on the building (e.g. walls facing west and east) and these sensors

    can control different groups of blinds. You can also define the opposite action: dimming. If the sensor

    detects strong sunshine, it will lower the blinds.

    SOU sensor - outer sensor of the lighting intensityADC2-40M - converter of the outer sensor signal to the bus

    Wall group button to control 1, 2 and 4 blinds (WSB2-20, WSB2-40, WSB2-80)

    It is also possible to co nnect wireless RF Controls in the shape of a button or key tag).

    The number of actuators must match the type of blinds::

    JA2-02B/DC for blinds installed inside or between double-glazed windows (uses 24V DC)

    JA2-02B for blinds on the o utside (uses 230V AC)

    RFJA-12B for wireless control

    The blinds can also be controlled

    by means of light scenariosThe blinds go up automatically

    with the first rays of sun

    BLINDS

    SHUTTER

    The blinds and the roof of the pool close automatically in bad weather.

    Sensors:

    Actuators:

    The blinds can also be controlled by means of light scenarios.

    Sensors:

    The weather station observes the speed o f the wind, rainfall, humidity, temperature and light. Combinations of these quantities enable defining conditions

    under which the system makes the outer wall blinds or swimming pool roof close. In this w ay you can protect your property against adverse weather (storms,

    continuous rainfall, high/low temperatures, excessive sunshine etc.). Or you can combine values of temperature and light in order to pr otect the water in your

    swimming pool and windows fr om strong sunshine. All you have to do is to set an a ppropriate configuration in the IDM.

    Weather station MFWS

    The number of actuators must match the type of blinds:

    JA2-02B/DC for blinds installed inside or between double-glazed windows (uses 24V DC)

    JA2-02B for blinds on the o utside (uses 230V AC))RFJA-12B for wireless control

    It is possible to add the controls of blinds to the light scenes. You always pull them down so that your neighbours won't see you, anyway. Press the Watching

    TV button on the wall control unit and the system will take ca re of the rest:

    It will set the lights for the defined scene

    It will pull down defined blinds

    It will turn on the TV (or projector) and audio

    If the blind controls are installed in the system, no other actuators or sensors are needed. Everything is a matter of smart settings.

  • 8/7/2019 StarterKit EN

    8/13

    Starter itK

    Outer blinds will put burglars off.

    In the event of trespassing and/or burglar alarm, it is possible to lower all blinds immediately and prevent the burglar from accessing the building

    (or at least make it more difficult). Moreover, the burglar will realise that the building is secured the smart way and will decide to move on to a place

    where no such obstacles occur. The command to lower the blinds can also be issued via a mobile phone or a PC connected to the internet.

    The police statistics show that most burglars enter buildings through windows because it is the easiest way. Even a novice burglar will find it

    extremely easy to pry a window open, especially where no security blinds are installed to prevent unauthorised access.

    Not only does the engine propelled blind ensure that the building cannot be broken into, but it also offers saving of energy as well as thermal and acoustic

    isolation. It helps to turn your home into an oasis of peace and quiet protecting you from intrusive looks and br inging you true and untroubled privacy, which

    is everyone's natural need, especially in these hurried times.

    Lowered blinds contribute toan atmosphere of peace and privacy

    The blinds will go up with the first rays of sunso that you can enjoy a pleasant morning

    Lowered blinds will make watching TVmore pleasant on sunny days

    Controlling blinds is necessary if youwant to achieve perfect light scenes?

    SHUTTER

    The Blinds StarterKit contains:

    JA2-02B blind actuator for 1 blind

    This unit is intended to control the drives of blinds, garage doors, entrance gates etc., which are controlled in two directions

    and feature a built-in end sensor: thermal sensor plug.

    WSB2-40 wall control unit with shortcut controlThe control unit features an integrated temperature sensor, micro buttons and a LED indicator in every cradle.

    Connection diagram:

    CIB+

    CIB-

    AC 230V LN

    JA2-02B

    L

    UP/DOWN

    RUN

    JA2-02B

    L

    UP/DOWN

    RUN

    SA2-04M WSB2-40 2 x JA2-02B

    i

  • 8/7/2019 StarterKit EN

    9/13

    Starter itK

    In these latitudes, virtually no

    building can do without heating.Be it a boiler burning solid fuels,

    bio fuels, central heating, electric

    heating, electric or water floor

    heating, thermal pumps, fireplace,

    fan coil or ventilation system, theINELS will enable you to control

    them all in an effective and

    convenient way so that you are

    pleased not only by the warmth,

    but also by your energy bills. Everysource of heating requires

    different regulation. INELS willcope with each and will also

    enable you to connect the weather

    station in a sophisticated way and

    to include the controls of blinds asanother insulation element

    preventing the leakage of heat or a

    solar system as a source of heat. It i s

    not necessary to install a separate

    control unit for every technology,so you will cut down on purchase

    costs.

    HEATING

    Heating medium: Water

    Even nowadays, so-called central heating is by far the most widespread way of heating. The water

    warms up the radiator which in turn warms up the ai r. If no thermal heads are installed on the valves

    of the radiators, it is impossible to regulate heating except by turning the boiler on or off.

    The drawbacks of such regulation are obvious: all parts of the building are heated, but regulated in

    a single place (where the thermostat is located). The INELS system brings a smart solution: use of

    thermal heads that can be controlled electrically.

    There are 2 types of thermal heads:

    1) those that can close/open the valve c ompletely and

    2) those that close/open the valve in i ncrements, i.e. in proportion to the temperature.INELS features a special actuator for both types which can be fitted in the installation case near

    the thermal head. The actuator also features an output for a thermal sensor so that you can scan and

    control temperature merely in the room where the radiator is located. The same principle also applies

    to water floor heating or fan coils.

    HEATING

    Sensors:

    Actuators:

    Thermal sensor TC to be connected to HC2-01B actuator

    HC2-01B/AC thermal head controller to control the thermal heads - option 1) (closed/open) for 24 - 230V AC power supply.

    - Recommended thermal head: Mhlenhoff ALPHA AA 230 V

    HC2-01B/AC thermal head controller to control the thermal heads - option 2) (joint regulation) for 0 - 10V.

    - Reco mmended thermal head: Mhlenhoff ALPHA AA 0-10 V

    Heating medium: Electricity

    Sensors:

    Actuators:

    Thermal pumps, solar panels and other sources of heat

    Sensors:

    Actuators:

    Electrical heating is very easy to regulate. No matter whether you have direct convectors, floor cable, glowing panels or electric fan coils, you can easily turn

    them on or off with any switch actuator. Like thermal heads, this offers the advantage to use the SA2-01B switch actuator to include in the installation case, as it

    allows switching up to 4000VA and features an input for a thermal sensor.

    Thermal sensors TC to be connected to any SA2-0x actuator

    SA2-01B 1x 16A output to be included in the installation caseSA2-02B 2x 8A output to be included in the installation case

    SA2-02M, SA2-04M, SA2-012M - 2x, 4x and 12x 16 A outputs to be included in the switch board

    The regulation of a more complex system is done through scanning the temperatures in required places and subsequent switching on and off of relevant

    devices (pumps, servo valves etc.). The regulation algorithm is set in the IDM. The INELS system can also communicate with other systems through the RS232

    serial line. At any rate, we recommend you to have these advanced settings of the regulation done by professionals.

    Thermal sensor of the TC type, Ni100/1000, Pt100/1000 or other

    TI2-04B a unit enabling the connection of up to 4 TC thermal sensors

    ADC2-40M a unit enabling the connection of up to 4 Ni100/1000, Pt100/1000 thermal sensors

    Any SA2-0x switch actuator

    DAC2-04M (B) 0-10V converter to control the servo drives, thermal valves etc.

    Regulation of heating in individual roomsH ea ti ng m ed iu m - e le ct ri ci ty H ea ti ng m ed iu m - w at er

    S iK

  • 8/7/2019 StarterKit EN

    10/13

    Connection diagram:

    Alpha AA 230V thermal head

    Is used to regulate the thermostat valves of the floor, radiator and convector heating.

    HC2-01B/AC thermal head controller

    Is used to switch the thermal heads 0/1 in 24-230V AC voltage range. The actuator is equipped with an input for measuring

    the temperature by means of a TC or TZ sensor and is to be included in the installation case.

    IART2-1 room thermal regulator

    Is used to regulate the temperature in a room or building. The regulator knob enables one to control the given heating/cooling

    circuit. The buttons are used to alter the mode of the circuit. The sensor features a built-in thermal sensor.

    Components of the Heating StartKit:

    AC 230V

    CIB+

    CIB-

    L

    N

    AC 230V

    L

    N

    3 x HC2-01B/AC

    Under floor heating

    3 x Thermo sensor TC

    EST-2 3.5 TFT touch screen

    A control featuring a touch screen to be included in the installation case. It enables controlling the functions of the INELS

    system.

    HEATING

    The weather station sends an impulse to switch onthe heating if the weather is cold

    The regulation of heating is automatic according tothe programme or manually controlled

    Settings in the IDM programme

    Radiators are controlled separately

    by means of thermal heads

    Starter itK

    How do I intervene with the regulation?

    How does the regulation work?

    Of course, the system can be controlled without any co mputer. The INELS offers you several choices:

    IART2-1 - an analogue thermostat in the design of the Elegant switch to be included in the installation case, the multiple case enables

    combinations with other devices. This control enables configuring the preset temperatures in +/- 3 C increments and/or switching the heating off

    completely.

    IDRT2-1- a digital thermostat in the design of the Elegant switch to be included in the installation case, the multiple case enables combinations

    with other devices. The function is the same as that o f IART2, but it also contains a display and allows configuring the heating schedule.

    EST-2 - a control featuring a touch screen in the Logus90 switch design to be included in the installation case. Besides controlling heating the EST-2enables controlling other functions of the INELS intelligent system. In preparation, sale from 08 /2009..

    The IDM configuration software features a component dedicated to the regulation of heating. In practice, it is possible to use any thermal sensor included in

    the system (i.e. according to the temperature in the location of the sensor) to control any heating component (i.e. place where an actuator is located)

    separately (every room may be set a different temperature). In this way it is possible to set the system from basic conditions up to a sophisticated and

    comprehensive solution with a number of thermal inputs (e.g. outer temperature, temperature of the floor, temperature of the boiler etc.). The IDM also

    enables you to set time limits of heating in the same way as the digital thermostat. The key advantage brought by the INELS system is an overview of

    the conditions of heating displayed on the touch screen and/or in the IDM as the ground plan of the building. In this way, you can switch on or regulate the

    heating even if you are a way or late...

  • 8/7/2019 StarterKit EN

    11/13

    CIRCUIT BREAKERS

    & PROTECTORS & FUSES

    HOUSE SWITCHES

    AND SOCKETS

    MODULAR

    ELECTRONIC DEVICES

    REMOTE

    CONTROL

    R

    Next portfolio products from offer ELKO EP, s.r.o.:

  • 8/7/2019 StarterKit EN

    12/13

    Overview of functions of the INELS system

    Controlling lights,

    light scenes depending on the intensity of exterior light,

    movement or time

    Regulating heating and air conditioning

    in every room (heating circuit) separately, regulating

    temperature according to the weather outside

    Controlling outer blinds,

    garage doors, entrance gates and swimming pool roofs

    Security system

    monitoring movement, protection against burglary

    Fire prevention through detection of gas or smoke

    Simulation of presence

    Controlling blinds in defined times automatically,

    switching lights on and off arbitrarily

    Central controls

    of selected lights and devices, switching socket circuits

    by a single pressing of a button

    Controlling appliances

    according to time / temperature / intensity of light orother preset modes makes is possible to control any

    appliances connected to the INELS system

  • 8/7/2019 StarterKit EN

    13/13

    LIGHTING

    169 42/

    ALARMHEATING REMOTECONTROL INTERNET GSM SHUTTER

    ELKO EP, s.r.o.| Palackho 493, 769 01 | Holeov - Vetuly | Czech Republic | Tel +420 573 514 211 Fax +420 573 514 227 [email protected]. Publication | 2009

    | |